Catalogue Sheet: Premier™ Series

Catalogue Sheet: Premier™ Series
Project/Location:
Contractor:
Premier™ Series
Date:
Thermoplastic, 6 and 12V
Prepared by:
Features
Typical specifications
• Designed with aesthetics, ease of installation and performance
in mind
Supply and install the Emergi-Lite® Premier™ Series battery unit
equipment. The unit construction shall include a housing and a front
cover of high-impact thermoplastic moulded in white. No screws
shall be necessary to hold the front cover to the housing. The unit
shall be equipped with two emergency heads with adjustable swivels
and MR-16 lamps of
V
W protected by snap-on shockabsorbent, clear polycarbonate covers. The unit shall be suitable for
wall mount or as otherwise specified.
The unit equipment shall have a dual-voltage input of 120/347VAC
and shall be equipped with a test switch and a green pilot light,
located on the left side. The housing shall host the battery and the
battery charger. The battery charger and other unit functions shall be
driven by a micro-controller. All electronic circuitry shall be installed
on a single printed circuit board.
When specified, the unit equipped with auto-test shall automatically
self-test for one minute every 30 days, 10 minutes every 6 months
and 30 minutes annually. When a fault is detected, the bi-colour pilot
light shall turn from green to red and start flashing. A legend on a
label next to the pilot light shall display the source of failure: battery,
charger circuitry or lamp load.
The unit equipment shall be listed to the standard CSA 22.2 No.141.
.
The unit equipment shall be Emergi-Lite® model:
• Simple, compact and contemporary design
• Wall-mount, ceiling-mount flat or pendant installation
• Two-piece housing of injection-molded thermoplastic
• Two MR16 halogen lamps, shielded by clear polycarbonate covers
• Available with long lasting MR16 LED lamps
• Sealed, maintenance-free, Lead-Calcium battery
• Dual voltage input: 120/347VAC.
• Up to 150W of total battery capacity
• Auto-diagnostics (optional)
• NEXUS® interface (optional)
• Certified CSA 22.2 No.141
Wire guards
460.0114-E
Wall Mount or flat ceiling mount
REPLACEMENT LAMPS
ordering code
lamp type
580.0079-E
MR16 halogen
voltage/ wattage
6V-10W
580.0080-E
MR16 halogen
12V-12W
580.0064-E
MR16 halogen
12V-20W
580.0093-E
MR16 LED
12V-4W
580.0097-E
MR16 LED
6V-4W
580.0104-E
MR16 LED
12V-5W
580.0106-E
MR16 LED
12V-6W
Premier™ family
116
Premier™ Combo Series
Premier™ Exit Series
P. 56-57
P. 55
Project/Location:
Contractor:
Premier™ Series
Date:
Prepared by:
Thermoplastic, 6 and 12V
Dimensions
Dimensions are approximate and subject to change.
105/8” [26.9 cm]
121/4” [31.0 cm]
37/8” [9.8 cm]
Flat Ceiling Mount
Power consumption and unit rating
Model
Wattage Capacity
AC Specs
30min
1h00
1h30
2h00
PRE40
40
23
16
12
-
PRE72
72
42
30
24
12
12PRE80
120/347VAC
0.25 / 0.09 A
4h00
80
44
32
26
13
12PRE120
120
70
50
40
20
12PRE150
150
84
60
48
24
ordering information
Series
06PRE= 6V
Capacity
40= 40W
72= 72W
12PRE= 12V 80= 80W
120= 120W
150= 150W
colour
Voltage
W= factory
white
B= black
Blank=
120/347VAC
2= 120/277VAC
Unit Type
Blank= standard
U= auto-diagnostics*
UN= a
uto-diagnostics
non-audible*
NEX= NEXUS® system
interface**
NEXRF= N
EXUS® wireless
system interface**
* Minimum lamp load required: 20%
of unit capacity
** Not all options are available with
the Nexus® system. Please consult
your sales representative
EXAMPLE: 06PRE40W/2MI
117
Options
Blank= no options
CM= ceiling mount
D3= time delay
(15 minutes)
LC= line cord (120V)
PM= pendant mount
Heads
/0= no
heads
/2= t wo
heads
Lamps
LA= MR16 LED, 6V-4W
LG= M
R16 LED,
12V-4W
LI= M
R16 LED,
12V-5W
LJ= M
R16 LED,
12V-6W
MI= MR16, 6V-6W
MJ= MR16, 6V-10W
MK= MR16, 12V-12W
MG= MR16, 12V-20W
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement