CONTENTS GENERAL INFORMATION

Conformity And Range

The Instructions Before Use

Name of Parts

Technical Data

Outdoor Unit Working Temperature Range

Electrical Connections

Installing The Outdoor Unit

Bleeding

Maintenance

Installation Dimension Diagram

Check After Installation

The products in this manual may be different with the real one, according to different models, some models have displayer and some models without displayer, the position and shape of the displayer please refer to the real one.

8

8

9

4

5

9

10

1

2

3

4

CONFORMITY AND RANGE

The air conditioner you have purchased is in conformity with the following

American

Directives UL1995:

GENERAL INFORMATION

Please read this owner's manual carefully before operating the unit and keep it carefully for consultation.

Only use the air conditioner as instructed in this booklet. These instructions are not intended to cover every possible condition and situation. As with any electrical household appliance, common sense and caution are therefore always recommended for installation, operation and maintenance.

1

THE INSTRUCTIONS BEFORE USE

GENERAL INFORMATION

When having a burning smell or smoke, please turn off the power supply and contact with the service center .

WARNING

The power supply must adopt the special circuit that with air switch protection and assure it has enough capacity. The unit will be turned on or off according to your requirement automatically, please do not turn on or turn off the unit frequently, otherwise disadvantage effect may be caused to the unit.

Never cut off or damage power cables and control wires. If the power cable and signal control wire were damaged, change them by professional

If the abnormity still exists, the unit may be damaged, and may cause electric shock or fire.

Power must adopts the special circuit to prevent fire.

Disconnect the power supply if long putting the air conditioner out of use.

Never damage the electric wire or use the electric wire which is not appointed.

Otherwise, it can cause electric shock or fire.

When cleaning, it is necessary to stop driving and turn off the power supply.

Cut off power supply

Otherwise, the accumulated dusts may cause overheating or fire.

Rated voltage of this air conditioner

220-240V,50Hz,The compressor will vibrate sharply if the voltage is too low, resulting in damage to refrigerating system. Electrical component are easy to damage if the voltage is too high.

Otherwise, it will cause overheating or fire.

Don't attempt to repair the air conditioner by yourself.

Otherwise, it may cause electric shock or damage.

Please note whether the installed stand is firm enough or not.

Don't step on the top of the outdoor unit or place something on it.

The wrong repair will lead to an electric shock or fire, so you should contact the service center to repair.

Earthing: The unit must be reliably earthed. The earthing cable shall be connected to the special earthing device in the construction.

If it is damaged, it may lead to the fall of the unit and cause the injury.

As falling off the outdoor unit can be dangerous.

2

NAME OF PARTS

AM2O-51HPDC1:

Warning

Be sure to cut off the power supply before cleaning the air conditioner; otherwise electric shock might happen.

Wetting of air conditioner may cause the risk of electric shock. Make sure not to wash your air conditioner in any case.

Volatile liquids such as thinner or gasoline will cause damage to the appearance of air conditioner. (Only use soft dry cloth moist cloth clean the air conditioner cabinet).

This product must not be disposed together with the domestic waste.

This product has to be disposed at an authorized place for recycling of electrical and electronic appliances.

The temperature of refrigerant circuit will be high,please keep the interconnection cable away from the copper tube.

GENERAL INFORMATION

OUTDOOR UNIT

No. Description

1 Air outlet grille

2 Valve

1

Note: the above figures are only intended to be a simple diagram of the appliance and may not correspond to the appearance of the units that have been purchased.

2

AM4O-81HPDC1:

Warning

If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard.

Be sure to cut off the power supply before cleaning the air conditioner; otherwise electric shock might happen.

Wetting of air conditioner may cause the risk of electric shock. Make sure not to wash your air conditioner in any case.

Volatile liquids such as thinner or gasoline will cause damage to the appearance of air conditioner. (Only use soft dry cloth moist cloth clean the air conditioner cabinet).

Do not dispose this product as unsorted municipal waste.

Collection of such waste separately for special treatment is necessary.

The temperature of refrigerant circuit will be high,please keep the interconnection cable away from the copper tube.

OUTDOOR UNIT

No. Description

1 Air outlet grille

2 Valve

Note: the above figures are only intended to be a simple diagram of the appliance and may not correspond to the appearance of the units that have been purchased.

1

2

3

4

TECHNICAL DATA

MODE

Electrical data

Electricity supply

Fuse or air switch

Minimum power cord section

Refrigerant gas(R410A)

Size and clearance

L P

H

L

P

H

TECHNICAL DATA

MODE

Electrical data

Electricity supply

Fuse or air switch

Minimum power cord section

Refrigerant gas(R410A)

Size and clearance

L

P

H

L

P

H

GENERAL INFORM ATION

AM2O-51HPDC1

220-240V~,50Hz

25

2.5

1400

2

818

378

596 mm mm mm

GENERA L INFORM ATION

AM4O-81HPDC1

220-240V~,50Hz

40

4.0

2200 mm g

2

890

362

700 mm mm mm

OUTDOOR UNIT WORKING TEMPERATURE RANGE

Maximum cooling

Minimum cooling

Maximum heating

Minimum heating

Outdoor side DB/WB( )

48/c

-5/-

27/-

-15/-

GENERAL INFORM ATION

ELECTRICAL CONNECTIONS

AM2O-51HPDC1:

1. Remove the handle at the right side plate of the outdoor unit (one screw).

2

.

Remove the cable clamp, connect the power connection cable with the terminal at the row of connection and fix

the connection. The fitting line distributing must be consistent with the indoor unit. terminal of line bank.

Wiring should meet that of indoor unit.

3.

Fix power connection wire by wire clamp.

4.

Ensure wire has been fixed well.

5.

Install the handle.

AM2O-51HPDC1

L

Front side plate

To unit A

INSTALLER

To unit B

Handle

An all-pole disconnection switch having a contact separation of at least 3mm in all pole should be connected in fixed wiring.

Wrong wire connection may cause malfunction of some electric components.After fixing cable, ensure that leads between connection to fixed point have some space.

The connection pipes and the connectiong wirings of the unit A and unit B must be corresponding to each other respective.

The appliance shall be installed in accordance with national wiring regulations.

Note: the above figures are only intended to be a simple diagram of the a ppliance and m appearance of the units that have been purchased.

L

Power connecting cord

Power connecting cord

To the power supply

5

ELECTRICAL CONNECTIONS

AM4O-81HPDC1:

1. Remove the handle at the right side plate of the outdoor unit (one screw).

2

.

Remove the cable clamp, connect the power connection cable with the terminal at the row of connection and fix

the connection. The fitting line distributing must be consistent with the indoor unit. terminal of line bank.

Wiring should meet that of indoor unit.

3.

Fix power connection wire by wire clamp.

4.

Ensure wire has been fixed well.

5.

Install the handle.

INSTALLER

An all-pole disconnection switch having a contact separation of at least 3mm in all pole should be connected in fixed wiring.

Wrong wire connection may cause malfunction of some electric components.After fixing cable, ensure that leads between connection to fixed point have some space.

The connect ion pipes and the connectiong wirings of the unit A ,unit B,unit C and unit D must be corresponding to each other respective.

The applian ce shall be in st alled in accordance wit h national wiring regulations.

Do not install the outdoor unit where it is exposed to the sunlight.

Front side plate

To unit A To unit B

L

Power cord

To the power supply

L interconnection cable interconnection cable

Handle

To unit C To unit D interconnection cable interconnection cable

Outdoor unit

Indoor unit

HANDLING

After having removed the packaging, check that the contents are intact and complete.

The outdoor unit must always be kept upright.

USER

Handling must be done by suitably e quipped qua lified technical personnel using equipment that is for suitable the weight of the a ppliance .

INSTALLING THE OUTDOOR UNIT

Location

Use bolts to secure the unit to a flat, solid floor.

When mounting the unit on a wall or the roof, make sure the support is firmly secured so that it cannot move in the event of intense vibrations or a strong wind.

Do not install the outdoor unit in pits or air vents

Installing the pipes

Use suitable connecting pipes and equipment for the refrigerant R410A.

The refrigerant pipes must not exceed the maximum heights 10m.

Wrap all the refrigerant pipes and joints.

Tighten the connections using two wrenches working in opposite directions.

Caution: Installation Must be Performed in Accordance with the NEC/CEC by Authorized Personnel Only.

BLEEDING

Humid air left inside the refrigerant circuit can cause compressor malfunction. After having connected the indoor and outdoor units, bleed the air and humidity from the refrigerant circuit using a vacuum pump.

INSTALLER

Install the drain fitting and the drain hose (for model with heat pump only)

Condensation is produced and flows from the outdoor unit when the appliance is operating in the heating mode. In order not to disturb neighbours and to respect the environment, install a drain fitting and a drain hose to channel the condensate water. Install the drain fitting and rubber washer on the outdoor unit chassis and connect a drain hose to it as shown in the figure.

INSTALLER

(1) Unscrew and remove the caps from the 2-way and 3way valves.

(2) Unscrew and remove the cap from the service valve.

(3) Connect the vacuum pump hose to the service valve.

(4) Operate the vacuum pump for 10-15 minutes until an absolute vacuum of 10 mm Hg has been reached.

(5) With the vacuum pump still in operation, close the low-pressure knob on the vacuum pump coupling. Stop the vacuum pump.

(6) Open the 2-way valve by 1/4 turn and then close it after 10 seconds. Check all the joints for leaks using liquid soap or an electronic leak device.

(7) Turn the body of the 2-way and 3-way valves. Disconnect the vacuum pump hose.

(8) Replace and tighten all the caps on the valves.

Diameter (mm)

ø 6

Twisting moment (N.m)

15

-

20

ø 9.52

ø 16

35-40

60-65

ø 12

ø 19

45

-

50

70

-

75

18K unit need to be installed the indoor unit

18K MODE:

Vacuum pump Vacuum pump

Vacuum pump

Service inlet

(2) Turn

(8) Secure

INDOOR

UNIT

Refrigerant fluid direction of flow

(8) Secure

2-way valve

3-way valve

(7) Turn to open fully

(2) Turn

(6) Open by 1/4 turn

(7) Turn to open fully

Valve cap

(2) Turn

(8) Secure

Valve cap Connect to the indoor unit conversion joint

7

MAINTENANCE

Use suitable instruments for the refrigerant R410A.

Do not use any other refrigerant than R410A.

Do not use mineral oils to clean the unit.

INSTALLER

INSTALLATION DIMENSION DIAGRAM

The installation must be done by trained and qualified service personnel with reliability according to this manual.

Contact service center before installation to avoid the malfunction due to unprofessional installation.

When picking up and moving the units, you must be guidedby trained and qualified person.

Ensure that the recommended the a ppliance .

AM2O-51HPDC1

50cm or more

Space to the cover

30cm or above

Space to the cover

200cm or above

(Air outlet side)

30cm or above

(Air inlet side)

50cm or above

Space to the wall

INSTALLER

30cm or above

Space to the cover

200cm or above

(Air outlet side)

AM4O-81HPDC1

50cm or more

Space to the cover

30cm or above

(Air inlet side)

50cm or above

Space to the wall

This is just the schematic plan, please refer to the actual product.

8

CHECK AFTER INSTALLATION

INSTALLER

Check Items

Is the installation reliable?

Problems Owing to Improper Installation

The unit may drop, vibrate or make noises

Has the gas leakage been checked? May cause unsatisfactory cooling (heating) effect

Is the thermal insulation of the unit sufficient?

May cause condensation and water dropping

Is the drainage smooth? May cause condensation and water dropping

Does the power supply voltage accord with the rated voltage specified on the nameplate?

Are the lines and pipelines correctly installed?

Has the unit been safely grounded?

Are the models of lines in conformity with requirements?

The unit may bread down or the components may be burned out

The unit may bread down or the components may be burned out

Risk of electrical leakage

The unit may bread down or the components may be burned out

Are there any obstacles near the air inlet and outlet of the indoor and outdoor units?

The unit may bread down or the components may be burned out

Have the length of refrigerating pipe and refrigerant charge amount been recorded?

It is not easy to decide the charge amount of refrigerant.