RPM4 Reference Pressure Monitor

Add to my manuals
4 Pages

advertisement

RPM4  Reference Pressure Monitor | Manualzz

RPM4

Reference Pressure

Monitor

Technical Data

Premium performance, unmatched features, compact and rugged

RPM4 is much more than a traditional pressure indicator

State of the art performance from very low pressure to 280 MPa (40 000 psi)… advanced on-board features…compact and rugged…full local and remote communications…RPM4 is the perfect solution in a wide variety of high end pressure calibration, testing and measurement applications.

Infinite Ranging

and

AutoRange

Infinite Ranging gives RPM4 unprecedented versatility in adapting to the specific range of operation. With the easy to use AutoRange function, a few simple key strokes or a single remote command string at the start of a test adapt every feature of the pressure monitor to optimize it for the range to be covered. Just enter the maximum pressure and the measurement mode.

AutoRange then:

Selects and activates the most appropriate Q-RPT to cover the specified range and measurement mode.

Sets the pressure unit of measure.

Activates absolute, gauge or compound gauge measurement.

Adjusts display resolution to the appropriate level for the range.

Adjusts overpressure alarms to the actual range of operation.

Reduces measurement uncertainty proportionally to the selected range

(premium class Q-RPTs only).

Note: The use of RPM4’s Infinite Ranging and AutoRange feature is recommended to optimize operation for a specific range but is not required to obtain “% of reading” measurement specifications.

Features

Stability based Ready/Not

Ready indication

Built-in fluid head corrections

User defined pressure units

Intelligent AutoZero

™ function

Remote [ENTER] switch

Large character, easy to read display

12 V dc power and battery pack option

RS-232 and IEEE-488 communications

FLASH memory and free em- bedded software upgrades on dhinstruments.com

PC based recalibration utility software included

Free LabVIEW ® drivers

SDS

Q-RPT Self Defense System

All Q-RPT modules up to 7 MPa (1 000 psi) include the Fluke Calibration unique Self

Defense System (SDS). SDS valves automatically isolate and vent the module’s Q-RPT when it is not in use or an overpressure is about to occur. With SDS, any Q-RPT module can be left connected to pressure up to 10

MPa (1 500 psi) without needing to isolate or disconnect it.

Advanced on-board functions

RPM4 provides a variety of advanced onboard pressure data functions including:

Special data such as pressure average over time, rate of change, hi/lo, freeze, deviation from set point

Differential mode directly measures the difference between two Q-RPTs including taring at the line pressure

Parallel measurement uses two Q-RPTs redundantly as one

Leak check measures average pressure rate of change over a user set time period

AutoTest automates calibration routines with tolerance testing and data logging

1 2 3 4 5 6

1. Pressure “Ready” (green) “Not Ready”

(red) based on real time measurement of pressure stability

2. Measured pressure

3. Pressure unit of measure

4. Measurement mode

5. Active Q-RPT module (Hi or Lo)

6. Remote activity indicator

7. Special functions display

7

7

8 9

1. HEAD: Make automatic fluid head corrections for differences in height between RPM4 and DUT.

2. SDS: User control of Q-RPT Self Defense

System.

3. AutoZ: Automated zeroing of reference pressure transducers in absolute and gauge measurement modes.

4. AutoRange: Automatically optimize all measurement characteristics for the exact range of operation.

5. LEAK CK: Run and view automated leak check functions.

6. DISPLAY: Select special display functions including rate, average, freeze, high/low, deviation.

7. RANGE: Select between Q-RPTs and saved AutoRange ranges.

8. Unit: Select pressure unit of measure.

9. Mode: Select pressure measurement mode (absolute, gauge, compound gauge, Hi-Lo differential).

1 4 2 5 3 6

2 Fluke Corporation RPM4™ Pressure Reference Monitor

Quartz reference pressure transducer (Q-RPT) modules

RPM4’s outstanding pressure measurement specifications are made possible by DHI's exclusive quartz reference pressure transducer (Q-RPT) modules.

Q-RPTs measure pressure by measuring the change in the natural oscillating frequency of a quartz crystal with pressure induced stress. To be qualified for use in a Q-RPT module, each transducer is individually evaluated and characterized using primary pressure standards. Only transducers exhibiting required levels of linearity, repeatability and stability are selected. A proprietary compensation model, derived from more than 15 years experience with thousands of quartz pressure transducers, is applied to optimize the metrological characteristics needed in a transfer standard. Standard and premium class

Q-RPT modules are available to best fit your performance and budgetary requirements.

A unique dynamic compensation for atmospheric pressure system uses an independent on-board barometer to provide seamless switching between absolute, gauge and compound gauge modes at any time. The barometer is used only to measure the small variations in atmospheric pressure that occur during gauge mode operation so its absolute error and drift over time do not contribute to measurement uncertainty.

Q-RPT modules offer the advantages of:

% of reading measurement uncertainty with AutoRange span turndown available

Negligible warm up time

No gas species dependence

Quartz element isolated from test medium

Low sensitivity to orientation

Q-RPT Module

Q-RPTs and ranges

A1.4M

A700K

A350K

A200K

A160K

A100K

BA100K 1

G200K

G100K

BG15K 2

G15K

A280M-L

A200M-L

A140M-L

A100M-L

A70M

A40M

A20M

A14M

A10M

A7M

A3.5M

A2M

Q-RPT designation

200

160

110

110

10 000

7 000

3 000

2 000

1 400

700

350

SI version

Maximum range (kPa) absolute

Maximum range (kPa) gauge

280 000

200 000

280 000

200 000

140 000

100 000

70 000

40 000

20 000

14 000

140 000

100 000

70 000

40 000

20 000

14 000

200

60

10

200

100

15

15

10 000

7 000

3 500

2 000

1 400

700

250

1 BA100K is a barometer with a low point of 70 kPa (10 psia).

2 BG15K is bidirectional gauge from -15 kPa to +15 kPa (-2.2 psi to +2.2 psi).

16

30

23

16

1 500

1 000

500

300

200

100

50

US version

Maximum range (kPa) absolute

Maximum range (kPa) gauge

40 000

30 000

40 000

30 000

20 000

15 000

10 000

6 000

3 000

2 000

20 000

15 000

10 000

6 000

3 000

2 000

30

15

15

8

1.5

2.2

2.2

1 500

1 000

500

300

200

100

35

Measurement mode(s) supported

Absolute gauge and compound gauge

Gauge only

Operating media

Oil standard, gas available

Gas standard, oil available

Gas only

SDS ™ Self

Defense

System

Not available

Included

PPC3

Q-RPT

RPM4

To UUT

Compatible with PPC3 automated pressure controller

RPM4 can be used as an external reference pressure measurement device for a DHI PPC3, fully automated, pressure controller/calibrator. One or two RPM4s can be “daisy chained” to PPC3 by 9 pin RS-232 cable(s). The RPM4's

Q-RPTs become part of the PPC3 system and are managed by PPC3 transparently to the user. There is only one test connection for the PPC3 system‘s full range of operation.

See the PPC3 product brochure for additional information.

3 Fluke Corporation RPM4™ Pressure Reference Monitor

General specifications

Power requirements

Normal operating temperature range

Vibration

Weight (typical)

Dimensions (H x W x D)

Communications ports

Operating modes

Pressure ranges

Operating media

Calibration

Pressure connections

CE Mark

RPM4: 85 V ac to 264 V ac, 50/60 Hz, 25 V a max and 12 V dc @ 9 Ahr

Battery/charger: 100 V ac to 240 V ac, 50/60 Hz

15 °C to 35 °C (59 °F to 95 °F)

Meets MIL-T-28800D

5 kg (11 lb)

RPM4: 10 cm x 22.7 cm x 24 cm (3.9 in x 8.9 in x 9.5 in)

Battery/charger: 8 cm x 22.5 cm x 20 cm (3.1 in x 8.9 in x 7.9 in)

RS-232 (COM1, COM2), IEEE-488.2

Absolute, gauge, compound gauge, differential

Vacuum to 280 MPa (40 000 psi)

Q-RPTs lower than A7M: Gas only

All others: Either gas or oil

A2LA accredited calibration report included

Up to A70M: 1/8 in. NPT F

Above A70M: DH500 (equivalent to AE250C)

Available, must be specified

Measured pressure (Q-RPT)

Warm up time 30 minute temperature stabilization recommended from cold power up

Resolution To 1 ppm, user adjustable

Predicted one year stability 1

± 0.005 % of reading all ranges and classes

Precision 2

Measurement

Uncertainty 3

Standard Class

± 0.008 % of reading or

0.0024 % of Q-RPT span, whichever is greater

0.0030 % of Q-RPT span, whichever is greater

4

± 0.010 % of reading or

4

Premium Class

Q-RPTs up to A10M (1 500 psi)

± 0.005 % of reading,

0.0015% of AutoRanged span or

0.0005 % of Q-RPT span, whichever is greater 5

± 0.008 % of reading,

0.0024 % of AutoRanged span or 0.0007 % of Q-RPT span, whichever is greater 5

Q-RPTs A14M to

A140M

(2 000 to 20 000 psi)

± 0.012 % of reading or

0.0036 % of Q-RPT span, whichever is greater 4

± 0.013 % of reading or

0.0039% of Q-RPT span, whichever is greater 4

Q-RPTs A200M to

A280M

(30 000 to 40 000 psi)

± 0.015 % of reading or

0.0045 % of Q-RPT span, whichever is greater 4

± 0.018 % of reading or

0.0054 % of Q-RPT span, whichever is greater 4

1 Predicted one year stability limit (k=2) assuming regular use of AutoZero function. Absolute mode predicted one year stability without use of AutoZ is ± (0.005 % Q-RPT span + 0.005 % of reading).

2 Combined linearity, hysteresis and repeatability.

Add ± 1 Pa (0.00015 psi) in gauge mode with an Axxx Q-RPT for the resolution and short term stability of the on-board barometer.

3 Maximum deviation of the Q-RPT indication from the true value of applied pressure including precision, predicted one year stability, temperature effect and calibration uncertainty, combined and expanded (k=2) following the ISO “Guide to the

Expression of Uncertainty in Measurement.”

4 % of reading value times measured pressure from 100 % to 30 % of Q-RPT span. Under 30

% of Q-RPT span, % of reading value times 30

% of Q-RPT span. For example, if the Q-RPT is a

Standard A160K, the Measurement Uncertainty in pressure is 0.010 % times the measured pressure to 48 kPa (160 kPa span x 30 %) and 0.0048 kPa

(160 kPa span x 30 % x 0.01 %) under 48 kPa.

5 % of reading value times measured pressure from

100 to 30 % of AutoRanged span. Under 30 % of

AutoRanged span, % of reading value times 30 % of AutoRanged span. If AutoRanged span is less then 30 % of maximum Q-RPT span, % of reading values times measured pressure, or % of reading times 9 % of Q-RPT span, whichever is greater.

For example, if the Q-RPT is a Premium A160K and

AutoRanged span is 160 kPa, the Measurement

Uncertainty in pressure is measured pressure x

0.008 % to 48 kPa (160 kPa AutoRanged span x

30 %) and 0.0038 kPa (160 kPa span x 30 % x

0.008 %) under 48 kPa. If the AutoRanged span is

100 kPa (greater than 30 % of 160 kPa maximum

Q-RPT span), the Measurement Uncertainty in pressure is measured pressure x 0.008 % to

30 kPa (100 kPa AutoRanged span x 30 %) and

0.0025 kPa (100 kPa span x 30 % x 0.008 %) under 30 kPa. If the AutoRanged span is

30 kPa (less than 30 % of the 160 kPa maximum

Q-RPT span), the Measurement Uncertainty in pressure is measured pressure x 0.008 % to

14.4 kPa (160 kPa maximum Q-RPT span x 9 %) and 0.0012 kPa (160 kPa maximum Q-RPT span x

9 % x 0.008 %) under 14.4 kPa.

Ordering information

Model

RPM4 04 -1 US units version, -2 SI units version

RPM4 05 CE mark

RPM4 06 Special calibration

RPM4 07 Special test fluid, Hi Q-RPT (specify fluid)

RPM4 08 Special test fluid, Lo Q-RPT (specify fluid)

RPM4 09 -1 Special configuration, air data

(A160K/A160K, A350K/A160K only)

Configuring an RPM4 model number

RPM4 mhhhac/mlllac

Where:

mhhhac Indicates the Hi Q-RPT designation. c indicates Q-RPT class (s for Standard, p for Premium).

mlllac Indicates the Lo Q-RPT designation and class.

Leave blank if there is no Lo Q-RPT.

See Q-RPTs and ranges table for available Q-RPTs.

Accessories

Battery Pack/Charger 12 V dc battery with charger

Rack Mount Kit Rack mount kit for standard 19 in. rack

Footswitch Remote [ENTER] footswitch

MPC1-1000 Manual gas pressure controller, for vacuum to 7 000 kPa (1 000 psi)

MPC1-3000 Manual gas pressure controller, for vacuum to 20 MPa (3 000 psi)

MPC1-D-1000 Manual pressure controller, for differential pressure at line pressure up to 7 000 kPa (1 000 psi)

MPC1-D-3000 Manual pressure controller, for differential pressure at line pressure up to 20 MPa (3 000 psi)

GPC1-16000 Assisted gas pressure controller, 110 MPa (16 000 psi)

MPG1-100M Manual hydraulic pressure generator/controller, 100 MPa (15 000 psi)

MPG1-200M Manual hydraulic pressure generator/controller,

200 MPa (30 000 psi)

OPG1-30000 Assisted hydraulic pressure generator/controller,

200 MPa (30 000 psi)

PK-7000-PPC/MPC Interconnections kit for RPM4 and MPC1 with quick-connector test connection

Fluke. Keeping your world up and running.

®

Fluke Calibration

PO Box 9090, Everett, WA 98206 U.S.A.

Fluke Europe B.V.

PO Box 1186, 5602 BD

Eindhoven, The Netherlands

For more information call:

In the U.S.A. (800) 443-5853 or

Fax (425) 446-5116

In Europe/M-East/Africa +31 (0) 40 2675 200 or

Fax +31 (0) 40 2675 222

In Canada (800)-36-FLUKE or

Fax (905) 890-6866

From other countries +1 (425) 446-5500 or

Fax +1 (425) 446-5116

Web access: http://www.fluke.com

©2010 Fluke Corporation.

Specifications subject to change without notice.

Printed in U.S.A. 6/2010 3031143B B-EN-N

4 Fluke Corporation RPM4™ Pressure Reference Monitor

Modification of this document is not permitted without written permission from Fluke Corporation.

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement