Dcm | TB1 | 510ULAC Accessories Installation Instructions Modular

510ULAC Accessories Installation Instructions Modular
510 SERIES
POWER SUPPLY
510ULAC ACCESSORIES
Schlage Lock Company
575 Birch Street
Forrestville, CT 06010
technical support: 866-322-1237
email: SESsupport@irco.com
web: www.irsupport.net
23446669-A
05-2009
510ULAC Accessories Installation Instructions
Table of Contents
510ULAC Accessories Installation Instructions
Table of Contents
Table of Contents
MODULAR OPTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Control Module Rack (CMR) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Dual Control Module (DCM) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Relay Control Module (RCM) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Time Delay Module (TDM) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
SYSTEM WIRING DIAGRAMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Dual Control Modules & Relay Control Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Special System Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
23446669-A
Page 2
05-2009
510ULAC Accessories Installation Instructions
Modular Options
MODULAR OPTIONS
Modular Options
1) Control Module Rack (CMR)
•
Description:
The CMR interfaces with the main board and power assembly via a 5” long plug-in cable.
A CMR acts as a backplane for Dual Control Modules and Relay Control Modules.
A 2-Rack CMR must first be installed when any Dual Control Modules or Relay Control Modules are to be used in your 510ULAC Power Supply.
6AMP, 3AG
J1
For cable connection
to main board
2-Rack CMR
•
Mounting a CMR to the Inside of the Cabinet:
Refer to the illustration below when mounting a 2-Rack CMR into a 510ULAC cabinet:
#8-32 x 1/2 LG. Phillips Pan Head screws
and lock washers
Qty=4
23446669-A
Page 3
05-2009
510ULAC Accessories Installation Instructions
Modular Options
CMR (continued)
•
Interfacing a CMR to the Main Board:
Using the 5” long cable assembly provided in the kit, refer to the illustration below for
interfacing the 2-Rack CMR to the main board:
Note that GREEN and WHITE wire
are inserted into same hole in this
connector. Center hole is plugged.
23446669-A
Main board
J3
Page 4
CMR
J1
05-2009
510ULAC Accessories Installation Instructions
Modular Options
2) Dual Control Module (DCM)
•
Description:
The DCM is a plug-in PCB providing separate sections for control of 2 individual doors.
Each section includes a 9-position screw terminal block for output power, control connection and SPDT dry contact outputs (rated 5A@30VDC). A 3-pin header in each section is
included to accept a Time Delay Module.
Each DCM provides circuitry and connection terminals for 2 individual locking systems.
J1
Never used when a
CMR is installed.
Connectors for TDMs.
Leave jumper in place
when TDM is not used.
JP1 & JP2:
When jumpers are intact, board is a DCM.
When jumpers are clipped or removed entirely,
board is an RCM (see next page).
Card edge
connector for
insertion into the
CMR
J1
Removable
terminal blocks.
May be lifted off
board, retaining
system connection
wiring.
K1
K2
D1
U1
C1
321
ID patch, door
number, or other
identification may
be recorded here.
TDM1
TB1
1 2
To control switch
Output power to lock
D2
C2
3
4 5
6
7
JP1
321
TDM2
JP2
8 9
C NC NO
Dry contact output
from control relay
(rated 5A @ 30VDC)
TB2
1 2
3
4 5
6
7
8 9
Same as TB1
* If EIR option is used, the output
power to the lock will be interrupted
upon activation of the emergency
override systems.
For typical system connection, see SYSTEM WIRING DIAGRAMS on page 11
23446669-A
Page 5
05-2009
510ULAC Accessories Installation Instructions
Modular Options
3) Relay Control Module (RCM)
•
Description:
The RCM is a plug-in PCB providing separate sections for control of 2 individual doors.
Each section includes a 9-position screw terminal block for control connection and DPDT
dry contact outputs (rated 5A@30VDC). A 3-pin header in each section is included to
accept a Time Delay Module.
Each RCM provides circuitry and connection terminals for 2 individual locking systems.
J1
Never used when a
CMR is installed.
Connectors for TDMs.
Leave jumper in place
when TDM is not used.
JP1 & JP2:
When jumpers are clipped or removed entirely,
board is an RCM. In this case, board is an
RCM, since JP1 & JP2 are missing.
Card edge
connector for
insertion into the
CMR
J1
Removable
terminal blocks.
May be lifted off
board, retaining
system connection
wiring.
K1
K2
D1
U1
C1
321
ID patch, door
number, or other
identification may
be recorded here.
TDM1
TB1
1 2
To control switch
3
4 5
6
NC NO C
7
JP1
8 9
C NC NO
DPDT dry contact outputs
from control relay
(rated 5A @ 30VDC)
23446669-A
D2
C2
Page 6
321
TDM2
JP2
TB2
1 2
3
4 5
6
7
8 9
Same as TB1
* If EIR option is used, the output
power to the lock will be interrupted
upon activation of the emergency
override systems.
05-2009
510ULAC Accessories Installation Instructions
Modular Options
•
Mounting DCM or RCM cards into the CMR:
Starting from the top slot downward, each DCM or RCM card pushes into a slot of the
CMR with the component side facing the transformer.
A 2-rack CMR with 2 DCM (or RCM) cards being installed.
23446669-A
Page 7
05-2009
510ULAC Accessories Installation Instructions
Modular Options
4) Time Delay Module (TDM)
•
Description:
The TDM is a plug-in PCB providing an adjustable (0-30 seconds) delay on relock (DCM)
or delay on state change (RCM).
A TDM can be added to each individual section of the DCM or RCM..
A separate TDM is needed for each locking system when this feature is required.
Time delay adjustment
30
0
CCW increases delay
Connector to mate with 3-pin
header on DCM or RCM board
Adhesive pad w/protective covering
23446669-A
Page 8
05-2009
510ULAC Accessories Installation Instructions
Modular Options
•
Mounting a TDM to a DCM or RCM:
Each DCM or RCM will accept either a single or two TDMs.
The locations for mounting the TDM are marked TDM1 and TDM2.
1.) If you are installing only one TDM, remove the jumper from TDM1
TDM1
If you are installing two TDMs, remove the jumpers from TDM1 & TDM2.
TDM1
TDM2
2. ) The protective covering should be removed from the underside of each TDM
exposing an adhesive pad.
Peel off protective
covering to expose
adhesive.
23446669-A
Page 9
05-2009
510ULAC Accessories Installation Instructions
Modular Options
•
Mounting a TDM to a DCM or RCM (continued):
3. ) Place the TDM over the 3-pin header on the DCM or RCM and carefully press
down to mate connector J1 on the TDM with the 3-pin header (TDM1) on the
DCM or RCM. Apply a bit more pressure to create a bond between the adhesive on the underside of the TDM and the DCM or RCM. Repeat this procedure for TDM2 on the DCM or RCM if two TDMs are being installed.
Illustrations below apply to both DCM cards and RCM cards.
1 TDM being installed (onto TDM1).
J1
3-pin header
TDM1
2 TDMs being installed (one onto TDM1 and one onto TDM2).
J1
J1
3-pin
header
TDM1
23446669-A
3-pin
header
TDM2
Page 10
05-2009
510ULAC Accessories Installation Instructions
System Wiring Diagrams
SYSTEM WIRING DIAGRAMS
System Wiring Diagrams
1) Dual Control Modules & Relay Control Modules
•
Description:
Each DCM or RCM card has two terminal blocks (TB1 & TB2) for connecting two individual systems. If required, one system can be connected to TB1, and TB2 may be interfaced to provide other system operations (voltage and/or dry contact outputs). Unless
noted, all connections shown may be repeated on TB2 for a second system. System types
may also be mixed, i.e., one on TB1 and a different one on TB2.
DCM or RCM Terminal Block Normal Conditions (power supply. input power or bat. power on)
DUAL CONTROL MODULE
LAYOUT
+
NC
RELAY
C C
NO
RELAY CONTROL MODULE
LAYOUT
RELAY
NC
NO
NO
FAIL-SAFE LOCK / CLOSED CONTROL
FIGURE M
(-) (+)
Common
Open
Closed
1 2 3 4 5 6 7 8 9
Control
LOCK
NC
NO
1 2 3 4 5 6 7 8 9
Dry Contact
Output
FAIL-SAFE LOCK / OPEN CONTROL
FIGURE N
(-)(+)
TB1
1 2 3 4 5 6 7 8 9
Control
LOCK
Dry Contact
Output
TDM OPTION DELAYS RELOCKING
DO NOT USE TDM OPTION
FAIL-SECURE LOCK / CLOSED CONTROL
FIGURE P
FAIL-SECURE LOCK / OPEN CONTROL
FIGURE R
(-) (+)
TB1
1 2 3 4 5 6 7 8 9
TB1
(-)(+)
LOCK
Common
Open
Closed
1 2 3 4 5 6 7 8 9
Control
Dry Contact
Output
TDM OPTION DELAYS RELOCKING
Control
LOCK
Common
Closed
Open
Figures
M, N, P and R
are applicable to
DCM only
C
TB1
1 2 3 4 5 6 7 8 9
TB1
C
Common
Closed
Open
TB1
NC
Dry Contact
Output
DO NOT USE TDM OPTION
NOTES:
1) If EIR option is used, the output power to the lock will be interrupted upon activation of the
emergency override system.
2) If the TDM option is used with a closed control, the lock will not relock until the preset time
has expired.
3) All drawings show lock in secure state.
23446669-A
Page 11
05-2009
510ULAC Accessories Installation Instructions
System Wiring Diagrams
2) Special System Wiring
FIGURE X: Wiring a DCM card for one locking system with two sets of dry contact outputs.
JUMPER
JUMPER
TB1
(-) (+)
TB2
Control
Common
Open
Closed
1 2 3 4 5 6 7 8 9
Common
Open
Closed
1 2 3 4 5 6 7 8 9
(-) (+)
Dry Contact
Output
LOCK
Dry Contact
Output
FIGURE Y: Safety interlock. Fail-safe locks - both doors normally closed and unlocked.
Opening one door locks other door until the open door is relocked.
Emergency unlock controls require a separate diagram.
(-) (+)
TB2
Common
Closed
Open
1 2 3 4 5 6 7 8 9
* Door #2
Status
Switch
(-) (+)
1 2 3 4 5 6 7 8 9
Common
Closed
Open
TB1
* Door #1
Status
Switch
Dry Contact
Output
Door #1
Lock
Dry Contact
Output
Door #2
Lock
*Shown with door
in closed position
NOTE: Do not use TDM option with this interlock.
FIGURE Z: Security interlock. Fail-safe locks - both doors normally closed and locked.
Unlocking one door voids release for other door until unlocked door is relocked.
TB1
** Door #1
MBS Status
Switch
(-) (+)
TB2
Control
Door #1
Lock
**Shown with door
in closed position
23446669-A
1 2 3 4 5 6 7 8 9
Common
Open
Closed
1 2 3 4 5 6 7 8 9
Dry Contact
Output
(-) (+)
Control
Door #2
Lock
Common
Open
Closed
** Door #2
MBS Status
Switch
Dry Contact
Output
* If EIR option is used, the output power to the lock will be interrupted
upon activation of the emergency override system.
Page 12
05-2009