G2RS Datasheet

G2RS Datasheet
General-purpose Relay
G2RS
Slim and Space-saving Power Plug-in Relay
• Lockable test button models now available.
• Built-in mechanical operation indicator.
• Provided with nameplate.
• AC type is equipped with a coil-disconnection self-diagnostic
function (LED type).
• High switching power (1-pole: 10 A).
• Environment-friendly (Cd, Pb free).
• Wide range of Sockets also available.
LR
Model Number Structure
■ Model Number Legend
G2R
1
2
3
4
5
6
7
5. Terminals
S:
Plug-in
6. Classification
Blank: General-purpose
N:
LED indicator
D:
Diode
ND:
LED indicator and diode
NI:
LED indicator with test button
NDI:
LED indicator and diode with test button
7. Rated Coil Voltage
1. Relay Function
Blank: General-purpose
2. Number of Poles
1:
1 pole
2:
2 poles
3. Contact Form
Blank: SPDT
4. Contact Type
Blank: Single
Ordering Information
■ List of Models
Classification
Plug-in terminal
General-purpose
Enclosure
rating
Unsealed
Coil ratings
Contact form
SPDT
AC/DC
G2R-1-S
DPDT
G2R-2-S
LED indicator
G2R-1-SN
G2R-2-SN
LED indicator with test button
G2R-1-SNI
G2R-2-SNI
Diode
G2R-1-SD
G2R-2-SD
LED indicator and diode
DC
G2R-1-SND
G2R-2-SND
LED indicator and diode with test button
G2R-1-SNDI
G2R-2-SNDI
Note: When ordering, add the rated coil voltage and "(S)" to the model number. Rated coil voltages are given in the coil ratings table.
New model
Example: G2R-1-S 12 VDC (S)
Rated coil voltage
General-purpose Relay
G2RS
1
■ Accessories (Order Separately)
Connecting Sockets
Applicable Relay model
Track/surface-mounting Socket
Rise-up terminal
Back-mounting Socket
Screwless clamp
terminal
Screw
terminal
Terminals
Model
1 pole
• P2RF-05-ESS (See note.) • P2RF-05S (See note.) • P2RF-05-E PCB terminals
+
+
G2R-1-S(N)(D)(ND)(NI)(NDI)
• P2RF-05
Solder terminals
(P2CM-ESS (option))
(P2CM-S (option))
P2R-05P, P2R-057P
2 poles
• P2RF-08-ESS (See note.) • P2RF-08S (See note.) • P2RF-08-E PCB terminals
+
+
G2R-2-S(N)(D)(ND)(NI)(NDI)
• P2RF-08
Solder terminals
(P2CM-ESS (option))
(P2CM-S (option))
P2R-08P, P2R-087P
P2R-05A
P2R-08A
Note: Use of the P2CM Clip & Release Lever is recommended to ensure stable mounting.
Accessories for Terminal Socket (Option)
Rise-up terminal
(P2RF-05-ESS, P2RF-08-ESS)
Clip & Release Lever
Screwless clamp terminal
(P2RF-05S, P2RF-08S)
P2CM-ESS (1pcs=1 bag of 10 pcs)
Socket Bridge
P2CM-S
----
Nameplate
P2RM-SR (for AC), P2RM-SB (for DC)
PYC-TR
R99-11 Nameplate for MY
Mounting Tracks
Applicable Socket
Description
Track-connecting Socket
Back-connecting Socket
Model
Mounting track
50 cm (l) x 7.3 mm (t): PFP-50N
1 m (l) x 7.3 mm (t): PFP-100N
1 m (l) x 16 mm (t): PFP-100N2
End plate
PFP-M
Spacer
PFP-S
Mounting plate
P2R-P*
*Used to mount several P2R-05A and P2R-08A Connecting Sockets side by side.
Specifications
■ Coil Ratings
Rated voltage
Rated current*
50 Hz
AC
Coil
resistance*
60 Hz
Coil inductance (H)
(ref. value)
Armature
OFF
24 V
43.5 mA
37.4 mA
253 Ω
0.81
1.55
110 V
9.5 mA
8.2 mA
5,566 Ω
13.33
26.83
120 V
8.6 mA
7.5 mA
7,286 Ω
16.13
32.46
230 V
4.4 mA
3.8 mA
27,172 Ω
72.68
143.90
240 V
3.7 mA
3.2 mA
30,360 Ω
90.58
182.34
Rated voltage
Rated current*
Coil
resistance*
Coil inductance (H)
(ref. value)
Armature
OFF
DC
Armature
ON
Armature
ON
6V
87.0 mA
69 Ω
0.25
0.48
12 V
43.2 mA
278 Ω
0.98
2.35
24 V
21.6 mA
1,113 Ω
3.60
8.25
48 V
11.4 mA
4,220 Ω
15.2
29.82
Must
operate
voltage
Must
release
voltage
General-purpose Relay G2RS
Power
consumption
(approx.)
% of rated voltage
80% max.
30% max.
Must
operate
voltage
Must
release
voltage
110%
Max.
voltage
0.9 VA at 60 Hz
Power
consumption
(approx.)
% of rated voltage
70% max.
15% min.
* The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of ±10%.
2
Max.
voltage
110%
0.53 W
■ Contact Ratings
Number of poles
1 pole
Load
Resistive load
(cosφ = 1)
Inductive load
(cosφ = 0.4; L/R = 7 ms)
Resistive load
(cosφ = 1)
2 poles
Inductive load
(cosφ = 0.4; L/R = 7 ms)
Rated load
10 A at 250 VAC;
10 A at 30 VDC
7.5 A at 250 VAC;
5 A at 30 VDC
5 A at 250 VAC;
5 A at 30 VDC
2 A at 250 VAC; 3 A at
30 VDC
Rated carry current
10 A
5A
Max. switching voltage
440 VAC, 125 VDC
380 VAC, 125 VDC
Max. switching current
10 A
Max. switching power
2,500 VA,
300 W
Failure rate (reference value)
100 mA at 5 VDC
5A
1,875 VA,
150 W
1,250 VA,
150 W
500 VA,
90 W
10 mA at 5 VDC
Note: P level: λ60 = 0.1 x 10-6/operation
■ Characteristics
Item
1 pole
Contact resistance
100 mΩ max.
Operate (set) time
15 ms max.
Release (reset) time
AC: 10 ms max.; DC: 5 ms max.
(w/built-in diode: 20 ms max.)
Max. operating
frequency
Mechanical:
Electrical:
2 poles
AC: 15 ms max.; DC: 10 ms max.
(w/built-in diode: 20 ms max.)
18,000 operations/hr
1,800 operations/hr (under rated load)
Insulation resistance
1,000 MΩ min. (at 500 VDC)
Dielectric strength
5,000 VAC, 50/60 Hz for 1 min between coil and
5,000 VAC, 50/60 Hz for 1 min between coil and contacts*;
contacts*;
3,000 VAC, 50/60 Hz for 1 min between contacts of different polarity
1,000 VAC, 50/60 Hz for 1 min between contacts of 1,000 VAC, 50/60 Hz for 1 min between contacts of same polarity
same polarity
Vibration resistance
Destruction:
Malfunction:
10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
Shock resistance
Destruction:
Malfunction:
1,000 m/s2
200 m/s2 when energized; 100 m/s2 when not energized
Endurance
Mechanical:
Electrical:
AC coil: 10,000,000 operations min.;
DC coil: 20,000,000 operations min. (at 18,000 operations/hr)
100,000 operations min. (at 1,800 operations/hr under rated load) (DC coil type)
Ambient temperature
Operating:
–40°C to 70°C (with no icing or condensation)
Ambient humidity
Operating:
5% to 85%
Weight
Approx. 21 g
Note: Values in the above table are the initial values.
*4,000 VAC, 50/60 Hz for 1 minute when the P2R-05A or P2R-08A Socket is mounted.
■ Approved Standards
UL 508 (File No. E41643)
Model
Contact
form
G2R-1-S SPDT
Coil ratings
5 to 110 VDC
5 to 240 VAC
G2R-2-S DPDT
IEC/VDE (EN61810)
Contact ratings
Operations
Contact
form
10 A, 30 VDC (resistive)
10 A, 250 VAC (general use)
TV-3 (NO contact only)
6 x 103
1 pole
6, 12, 24, 48 VDC
24, 110, 120, 230,
240 VAC
5 A, 440 VAC (cosφ = 1.0)
10 A, 250 VAC (cosφ = 1.0)
10 A, 30 VDC (0 ms)
100 x 103
5 A, 30 VDC (resistive)
5 A, 250 VAC (general use)
TV-3 (NO contact only)
6 x 103
2 poles
6, 12, 24, 48 VDC
24, 110, 120, 230,
240 VAC
5 A, 250 VAC (cosφ =1.0)
5 A, 30 VDC (0 ms)
100 x 103
CSA 22.2 No.0, No.14
(File No. LR31928)
Model
Contact
form
G2R-1-S SPDT
G2R-2-S DPDT
Coil ratings
5 to 110 VDC
5 to 240 VAC
Coil ratings
Contact ratings
Operations
LR
Number of
poles
Contact ratings
Operations
10 A, 30 VDC (resistive)
10 A, 250 VAC (general use)
TV-3 (NO contact only)
6 x 103
5 A, 30 VDC (resistive)
5 A, 250 VAC (general use)
TV-3 (NO contact only)
6 x 103
Coil ratings
Contact ratings
Operations
1 pole
5 to 110 VDC
5 to 240 VDC
10 A, 250 VAC (general use)
7.5 A, 250 VAC (PF0.4)
10 A, 30 VDC (resistive)
5A, 30VDC (L/R=7ms)
100 x 103
2 poles
5 to 110 VDC
5 to 240 VDC
5 A, 250 VAC (general use)
2 A, 250 VAC (PF0.4)
5 A, 30 VDC (resistive)
3A, 30VDC (L/R=7ms)
100 x 103
General-purpose Relay
G2RS
3
Engineering Data
Maximum Switching Power
Plug-in Relays
G2R-2-S
G2R-1-S
100
Switching current (A)
AC inductive load
(cosφ = 0.4)
AC resistive
load
10
DC resistive
load
DC inductive load
(L/R = 7 ms)
1
0.1
1
10
100
Switching current (A)
100
AC resistive
load
DC resistive
load
1
0.1
1000
AC inductive load
(cosφ = 0.4)
10
DC inductive load
(L/R = 7 ms)
1
10
Switching voltage (V)
100
1000
Switching voltage (V)
Endurance
Plug-in Relays
G2R-2-S
10,000
5,000
1,000
250-VAC/30-VDC
resistive load
500
100
250-VAC inductive load
(cosφ = 0.4)
30-VDC inductive load (L/R = 7ms)
50
Endurance (x103 operations)
Endurance (x103 operations)
G2R-1-S
5,000
1,000
500
30-VDC inductive load (L/R = 7ms)
250-VAC/30-VDC
resistive load
100
250-VAC
50 inductive load
(cosφ = 0.4)
Switching current (A)
Switching current (A)
Maximum voltage (%)
Ambient Temperature vs Maximum Coil Voltage
DC coil
AC coil
Note: The maximum voltage refers to the maximum
value in a varying range of operating power
voltage, not a continuous voltage.
Ambient temperature (°C)
4
General-purpose Relay G2RS
Technical and Environmental
Properties
Properties
1-Pole and 2 Pole Model
Tracking Resistance
Base 250
Environmental Protection
RT 1
Flammability Class
Base, Insulator, Spool
Case, Indicator,
Pushbutton
Pollution degree
2
Creepage Distance
8 mm
Clearance Distance
8 mm
Contact Material
AgSnIn
UL 94V-0
UL 94V-2
Typical information for reference only
The following data is provided as experimental and/or calculated
data for reference only. These fall under the category of typical
behaviour and the operation of individual relays will vary according to
the exact operating conditions
Typical Operate / Release times
1 pole model 2 pole model
AC Type (operate / release time)
6 / 8 ms
6 / 10 ms
DC Type (operate / release time)
12 / 4 ms
11 / 15 ms
Multiple Contact DC Switching Capacity
Switching capacity of DC resistive load
Switching Current (A)
10
G2R-2-S
1
2 contacts
in series
0.1
20
40
60
G2R-1S
80
100
120
140
160
180
200
220
Switching Voltage (Vdc)
Load Reduction Factor
1
Switching Current (A)
0.8
0.6
0.4
1
0.8
0.6
0.4
0.2
Cos(p.f.)
For AC inductive loads (such as solenoids, contactor coils, etc.) the
reduction factor corresponding to cos(p.f.) (cosine of power factor) is
multiplied by the rated current in order to identify the maximum allowable current. This approximation is not valid for loads with high inrush
currents such as electric motors or fluorescent lamps.
General-purpose Relay
G2RS
5
Dimensions
Note: All units are in millimeters unless otherwise indicated.
Relays with Plug-in Terminals
SPDT Relays
G2R-1-S, G2R-1-SN, G2R-1-SNI
G2R-1-SD, G2R-1-SND, G2R-1-SNDI
Terminal Arrangement/Internal Connections
(Bottom View)
G2R-1-SD (DC)
G2R-1-S
29 max.
1
13 max.
1
2
20
35.5 max.
5
4
3
G2R-1-SN, G2R-1-SNI (AC)
4.75
2
5
3
4
5
2
4
3
7.5
0.5
1
5
1
V
3
4
G2R-1-SN, G2R-1-SNI (DC)
1
DC
24
2
5
G2R-1-SND, G2R-1-SNDI (DC)
5.2
5.2
17.5
1
2
5
4
3
DPDT Relays
G2R-2-S, G2R-2-SN, G2R-2-SNI
G2R-2-SD, G2R-2-SND, G2R-2-SNDI
Terminal Arrangement/Internal Connections
(Bottom View)
G2R-2-S
1
2
3
4
8
7
6
5
13 max.
2.5
7.4
6
35.5 max.
General-purpose Relay G2RS
3
4
8
7
6
5
2
3
4
1
2
3
4
8
7
6
5
8
7
6
5
5
19.4
2
1
G2R-2-SND, G2R-2-SNDI (DC)
5
1
G2R-2-SN, G2R-2-SNI (DC)
8.9
2.4
G2R-2-SN, G2R-2-SNI (AC)
6.2
20
29 max.
0.5
G2R-2-SD (DC)
1
2
3
4
8
7
6
5
Track/Surface Mounting Sockets
P2RF-05-ESS
61
Terminal Arrangement
(Top View)
42.5
11
34.1
24
14
8
15.6
8.5
12
6 dia.
31
9.25
3.2 dia.
20.6
5.2
77.6
5.2
3.5
A1 A2
Option (with Clip and
Release Lever)
Standard model
7.6
24
P2RF-08-ESS
61
42.5
Terminal Arrangement
(Top View)
35.1
24
21 11
8.5
8
15.6
24 14
3.5
31
9.25
6 dia.
3.2 dia.
20.6
5
77.6
5
22 12
Option (with Clip and
Release Lever)
Standard model
A1 A2
7.6
24
Accessories for [email protected]
Clip and Release Lever
P2CM-ESS
14.5
21.7
19.7
37.1
5.8
2.1
4.5
8.4
15.6
34.4
13.2
22.9
General-purpose Relay
G2RS
7
38.2 max.
P2RF-05-S
Terminal Arrangement
(Top View)
36.5 max.
11
32.6
14
27.6
12
Option (with ejector and
label attached)
92.0 max.
Standard model
35.4
24.5
22.6
28.5
18.0 max.
A1 A2
(5.3)
32.6
Terminal Arrangement
(Top View)
38.2 max.
P2RF-08-S
36.5 max.
21 11
24 14
32.6
27.6
22 12
(3.4)
Standard model
35.4
92.0 max.
24.5
22.6
A1 A2
Option (with ejector
and label attached)
28.6
18.0 max.
(5.3)
32.6
Accessories for [email protected]
Socket Bridge
Clip and Release Lever
Insulating coating
9
14
16.8
40.35
36
L
1.2 dia. conductor (See note 1.)
8
General-purpose Relay G2RS
Terminal Arrangement
(Top View)
P2RF-05-E
Five, M3.5×7
2
48 max.
4
(14)
39.5
3
35.5
85.5 max.
Mounting Holes
(for Surface Mounting)
3.2-dia.
hole
(11)
2
(12)
39.5±0.1
3.5-dia.
hole
M3 or
3.5-dia.
hole
5
(A1)
(A2)
1
11.5
61 max.
16.0 max.
Note: Pin numbers in parentheses apply to DIN standard.
P2RF-08-E
2
Terminal Arrangement
(Top View)
2
1.5
Eight, M3×8
48.0 max.
Mounting Holes
(for Surface Mounting)
3
39.5
(21)
(22)
(24)
6
3
7
5
2
4
(11)
(12)
(14)
3.2-dia.
hole
35.5
85.5
max.
39.5±0.1
3.5-dia. hole
8
(A1)
(A2)
5
61.0
max.
1
M3 or
3.5-dia.
hole
11.5
16.0 max.
P2RF-05
2
7
Terminal Arrangement
(Top View)
Five, M3.5 x 8
4-dia. holes
Mounting Holes
(for Surface Mounting)
4.2-dia. hole
35.5
71.5 max.
30±0.05
4
19.5
30 max.
19.5 max.
M3 or 3.2-dia.
hole
54 max.
P2RF-08
2
7
Eight, M3.5 x 8
4-dia. holes
Terminal Arrangement
(Top View)
Mounting Holes
(for Surface Mounting)
4.2-dia. hole
35.5
71.5 max.
30±0.05
4
19.5 max.
19.5
30 max.
54 max.
M3 or 3.2-dia.
hole
General-purpose Relay
G2RS
9
Mounting Height of Relay with Track/Surface Mounting Sockets
[email protected]
[email protected]
62.0
66.5
70.5
67.0
[email protected]
[email protected]
72.0
70.6
65.0
74.6
28.6
(5.30)
Back-connecting Sockets
P2R-05P (1-pole)
4
1
Terminal Arrangement
(Bottom View)
14.5 max.
7
Mounting Holes
Tolerance: ±0.1
4
6
4.5
6
35.5 max.
15
Five,
1.6-dia.
holes
4.5
1.2
4
15
3.5
4
1.5
(5)
4
7
7
36.5 max.
P2R-08P (2-pole)
4
0.3
14.5 max.
7
Terminal Arrangement
(Bottom View)
Mounting Holes
7.5
Eight, 1.3-dia. holes
5
5
35.5 max.
20
1
5
5
20
2.8
1.5
(4.3)
7.5
Terminal plate thickness: 0.3
10
36.5 max.
General-purpose Relay G2RS
5
P2R-05A (1-pole)
7
14.5 max.
1.2
0.3
Terminal Arrangement
(Bottom View)
6.7
3.8
35.5 max.
5
16.7
Panel Cutout
Five, 3 x 1.8-dia. holes
13.6±0.1
6
36.5 max.
Terminal plate thickness: 0.3
P2R-08A (2-pole)
7
30.5±0.2
7
14.5 max.
1.2
0.3
5
5
35.5 max.
Recommended thickness of
the panel is 1.6 to 2.0 mm
20
2.6
2.8
1.5
Eight, 3 x 1.2-dia. holes
7.5
Terminal plate thickness: 0.3
P2R-057P
0.7
14 max.
8.7
16.4
10.4
1
36.5 max.
Terminal Arrangement
(Bottom View)
Mounting Holes
Five,
1.6-dia.
holes
4±0.1
6±0.1
37 max.29.6
4.5±0.1 15±0.1
8.7
4±0.1
5
7.4
7±0.1
41 max.
P2R-087P
14 max.
7.5
Terminal Arrangement
(Bottom View)
16.4
1
10.4
Mounting Holes
7.5
37 max. 29.1
Eight,
1.3-dia.
holes
5
5
20
7.4
8.9
(8.1)
41 max.
Mounting Height of Relay with Back-connecting Sockets
[email protected]
[email protected]
G2R Relay
44.5
G2R Relay
38.0
P2R-_P
Socket
[email protected]
P2R-_A
Socket
47.5
General-purpose Relay
G2RS
11
Mounting Tracks
PFP-100N, PFP-50N
PFP-100N2
16
7.3±0.15
4.5
4.5
15
25
25
25
25
10
10
1,000 (500)
35±0.3 27
27±0.15
35±0.3
15 (5)
15
1
25
25 15
25
25
10
10
24
29.2
1
1.5
1,000
It is recommended to use a panel 1.6 to 2.0 mm thick.
End Plate
Spacer
10
6.2
PFP-M
PFP-S
16
12
5
1.8
1
50
1.8
11.5
10
M4 x 8 pan
head screw
35.5 35.3
1.3
4.8
Precautions
!Caution
Do not use the test button for any purpose other than testing. Be
sure not to touch the test button accidentally as this will turn the
contacts ON. Before using the test button, confirm that circuits, the
load, and any other connected item will operate safely.
!Caution
Check that the test button is released before turning ON relay circuits.
!Caution
If the test button is pulled out too forcefully, it may bypass the momentary testing position and go straight into the locked position.
!Caution
Use an insulated tool when you operate the test button.
Precautions for [email protected] Connection
• Do not move the screwdriver up, down, or from side to side while it
is inserted in the hole. Doing so may cause damage to internal
components (e.g., deformation of the clamp spring or cracks in the
housing) or cause deterioration of insulation.
• Do not insert the screwdriver at an angle. Doing so may break the
side of the socket and result in a short-circuit.
12
34.8
44.3
General-purpose Relay G2RS
16.5
General-purpose Relay
G2RS
13
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Cat. No. J140-E2-02
14
In the interest of product improvement, specifications are subject to change without notice.