ftk/ftx-b wall mounted unit
EPLE03-11
WALL MOUNTED UNIT
Daikin air conditioners for your home
NEW
FTK/FTX-B
remote
control
(standard)
centralised
remote
control
(optional)
indoor unit FTK/X25,35B
vertical auto
swing
auto
restart
powerful
mode
auto cooling/
heating
changeover
(FTX)
auto fan
speed
fan only
(FTK)
fan speed
5 steps
air
purification
filter
movement
sensor
dry
programme
self
diagnosis
night set
mode
whisper
quiet
energy
efficiency
home leave
operation
24 hour
timer
• Flat front panel: its stylish appearance fits easily within any interior decor and is more easy
to clean
• Lightweight and compact
• The movement sensor automatically saves power consumption in unoccupied rooms
• The home leave operation saves energy during absence
• Powerful mode can be selected for rapid cooling and heating
• Washable front panel
• Air purification filter: - deodorises the air
- helps to prevent bacterial and viral propagation
• The outdoor unit can be installed on a roof or terrace
or placed against an outside wall.
• Outdoor units are fitted with a swing compressor,
renowned for their low noise and energy efficiency.
outdoor unit RK/X25,35B
• The remote control has a 24 hour timer
• The indoor unit also has a start/stop button mounted on the
front panel
• Up to 5 indoor units can be regulated from a single centralised
control
• Purpose-designed holder provided for the remote control
The use of integrated inverter control ensures maximum comfort and efficiency.
• Short start-up cycle
Inverter control enables the required room temperature to be achieved quicker
than with non-inverter units, in fact, start-up time is reduced by one third.
• 30% less power consumption
The inverter controller detects changes in room or outdoor conditions and
adjusts the indoor temperature to compensate within seconds.
Rapid response reduces power consumption to 30% lower than that of
non-inverter systems.
The air purification filter traps
fine dust as small as 0.01 microns
to purify the air in a room.
The filter is double-sided with an
air-cleaning electrostatic filter on
the front side and a deodorising
activated charcoal filter on the
rear side.
Air Purification
Filter
Pre-Filter
Cleaning
Deodorising
Rear
(Activated-charcoal
filter side)
Front
(Electrostatic filter side)
*Requires replacement only about once every 3 months.
1
2
3
4
5
25 °
Cooling
Heating
1
2
3
4
25 °
Cooling capacity increases with 10%. This is an added convenience for
those exceptionally hot days and can be made even when the
compressor is already rotating at high speed. Convenient for use upon
returning home on a hot day. This function automatically returns the
unit to its previous setting after 20 minutes.
5
Vertical auto swing automatically moves the
flaps up and down to ensure an even
distribution of air.
When the air conditioner is turned off, the
flaps shut automatically so that dust cannot
enter.
The flap angle can precisely be controlled with
a convenient five-step preset programme using
the digital display on the remote control.
The angle is initially set on step 5, and each
step represents a movement of 5°.
Inverter powerfuloperation button on
wireless remote control
During the occupant’s absence, the indoor temperature can be maintained at a preset level, according to user
preference. The home leave operation can be activated or deactivated via the remote control. This useful function saves
energy when the room is empty or when the occupant goes to bed. It also enables the room temperature to return
quickly to the set temperature. A lamp on the indoor unit indicates that the home leave operation has been activated.
Through the use of the “Timer-off circuit”, the room temperature gently
rises during cooling operation or falls during heating operation until the
preset temperature is reached before the unit stops.
This means you can sleep more comfortably without feeling a sudden
change in room temperature.
+0.5¡C
Set temp.
60min.
Timer Start
—2¡C
60min.
Timer Start
30min.
*1 Outdoor
*2 Outdoor
Set temp.
Timer *1
Course A
Timer *2
Course B
+0.5¡C
temp. is 27¡C or lower
temp. is higher than 27¡C
Capacity and power input
PAIR-COOLING ONLY
(air cooled)
INDOOR UNIT
OUTDOOR UNIT
Capacity (min.-nom.-max.)
Power input (min.-nom.-max.)
EER
Energy label
Annual energy consumption
cooling
cooling
kW
kW
cooling
cooling
kW/h
PAIR-HEAT PUMP
(air cooled)
INDOOR UNIT
OUTDOOR UNIT
Capacity (min.-nom.-max.)
cooling
heating
cooling
heating
kW
kW
kW
kW
cooling
heating
cooling
heating
kW/h
kW/h
Power input (min.-nom.-max.)
EER
COP
Energy label
Annual energy consumption
FTK25BVMB
RK25BVMB
FTK35BVMV
RK35BVMB
1.30-2.50-3.00
0.43-0.89-1.25
2.81
C
445
1.40-3.15-3.80
0.50-1.12-1.72
2.81
C
560
FTX25BVMB
RX25BVMB
FTX35BVMB
RX35BVMB
1.30-2.50-3.00
1.30-3.30-4.00
0.43-0.89-1.25
0.35-1.025-1.35
2.81
3.22
C
C
445
512.5
1.40-3.15-3.80
1.40-4.10-5.00
0.50-1.12-1.72
0.405-1.345-1.90
2.81
3.05
C
D
560
672.5
FTK/X25,35BVMB
Specifications indoor units
COOLING ONLY
Dimensions
Weight
Front panel colour
Air flow rate
Fan speed
Sound pressure level
Sound power level
Piping connections
FTK25BVMB
HxWxD
mm
kg
Fan speed
Sound pressure level
Sound power level
Piping connections
7.5
7.5
white
cooling (H/L)
cooling (H/L)
cooling (H)
liquid
gas
drain
m3/min
steps
dB(A)
dB(A)
mm
mm
mm
Heat insulation
HEAT PUMP
Dimensions
Weight
Front panel colour
Air flow rate
FTK35BVMB
273x784x195
7.7/4.2
7.7/4.5
5 steps, silent and auto
39/26
55
39/27
55
ø6.4
ø9.5
ø18.0
both liquid and gas pipes
FTX25BVMB
HxWxD
mm
kg
FTX35BVMB
273x784x195
7.5
7.5
white
cooling (H/L)
heating (H/L)
cooling (H/L)
heating (H/L)
cooling (H)
liquid
gas
drain
m3/min
m3/min
steps
dB(A)
dB(A)
dB(A)
mm
mm
mm
7.7/4.2
7.9/5.2
7.7/4.5
7.9/5.4
5 steps, silent and auto
39/26
39/26
55
39/27
39/27
55
ø6.4
ø9.5
ø18.0
both liquid and gas pipes
Heat insulation
Control systems
FTK/X-B
Wiring adapter for time clock/ normal open contact
remote control (1)
normal open pulse contact
Centralised control board
up to 5 rooms (2)
Central remote control
Unified ON/OFF control
Schedule timer
Interface adapter (3)
(1) Wiring adapter is supplied by Daikin. Timer and other devices: field supply.
(2) Wiring adapter is also required for each indoor unit.
(3) For DIII-NET adapter
25
35
KRP413A1S
KRP413A1S
KRC72
DCS302B51
DCS301B51
DCT301B51
KRP928A2S
Accessories indoor units
FTK/X-B
25
35
Air purification filter, with frame
Air purification filter, without frame
Anti-theft protection for remote control
KAF925B41
KAF925B42
KKF910A4
RK/X25,35BVMB
Specifications outdoor units
COOLING ONLY
RK25BVMB
Dimensions
HxWxD
Weight
Casing colour
Sound pressure level
cooling (H/L)
Sound power level
cooling (H)
Compressor
Refrigerant type
Amount of additional charge
Maximum piping length
Maximum level difference
Standard operation range cooling
from~to
HEAT PUMP
Dimensions
Weight
Casing colour
Sound pressure level
HxWxD
mm
kg
RK35BVMB
560x695x265
34
37
ivory white
dB(A)
dB(A)
g/m
m
m
°CDB
mm
kg
46/*
59
47/*
60
hermetically sealed swing type
R-410A
20 (for piping length exceeding 10m)
25
15
10~46
RX25BVMB
RX35BVMB
560x695x265
34
37
ivory white
cooling (H/L)
heating (H/L)
cooling/heating (H)
Sound power level
Compressor
Refrigerant type
Amount of additional charge
Maximum piping length
Maximum level difference
Standard operation range cooling
heating
from~to
from~to
dB(A)
dB(A)
dB(A)
46/*
47/*
59/*
47/*
48/*
60/*
hermetically sealed swing type
R-410A
20 (for piping length exceeding 10m)
15
15
10~46
-10~20
g/m
m
m
°CDB
°CWB
Accessories outdoor units
RK/X-B
25
Air direction adjustment grille
VM = 1~,220~240/220-230V,50Hz/60Hz
Nominal cooling capacities are based on: indoor temperature 27°CDB/19°CWB • outdoor temperature 35°CDB • refrigerant piping length 7.5m • level difference 0m.
Nominal heating capacities are based on: indoor temperature 20°CDB • outdoor temperature 7°CDB/6°CWB • refrigerant piping length 7.5m • level difference 0m.
Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat.
Units should be selected on nominal capacity. Max. capacity is limited to peak periods.
The sound pressure level is measured via a microphone at a certain distance from the unit (for measuring conditions: please refer to the technical databooks).
The sound power is an absolute value indicating the “power” which a sound source generates.
Energy label: scale from A (most efficient) to G (less efficient).
Annual energy consumption: based on average use of 500 running hours per year at full load (=nominal conditions)
Daikin’s unique position as a manufacturer of air conditioning equipment, compressors and ozonefriendly refrigerants has led to its close involvement in environmental issues.
For several years Daikin has had the intention to become a leader in the provision of environmental
friendly products. This challenge demands the eco design and development of a wide range of
products and an energy management system; which involves energy conservation and reduction of
waste.
Daikin products are distributed by:
Daikin Europe N.V. is approved by LRQA for its
Quality Management System in accordance with the
ISO9001 standard. ISO9001 pertains to quality
assurance regarding design, development,
manufacturing as well as to services related to the
product.
ISO14001 assures an effective environmental
management system in order to help protect human
health and the environment from the potential
impact of our activities, products and services and to
assist in maintaining and improving the quality of the
environment.
Daikin units comply with the European regulations
that guarantee the safety of the product.
Specifications are subject to change without prior notice.
Zandvoordestraat 300
B-8400 Oostende, Belgium
Internet: http://www.daikineurope.com
Daikin Europe N.V. is participating in the EUROVENT
Certification Programme. Products are as listed in the
EUROVENT Directory of Certified Products.
EPLE03-11 / 4,400 / 02/03 / La Movida
Printed on non-chlorinated paper / Printed in Belgium
Note: 1)
2)
3)
4)
5)
6)
7)
8)
9)
35
KPW937A4
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising