MQQ/MQM Series - Low Friction Cylinder Metal Seal Type

Add to My manuals
28 Pages

advertisement

MQQ/MQM Series - Low Friction Cylinder Metal Seal Type | Manualzz
CAT.ES20-156 A
Compact Low Friction Cylinder (Metal Seal Type)
Series MQQ
ø10, ø16, ø20, ø25, ø28
Series
MQQ
Lateral Load Resisting Low Friction Cylinder
(Metal Seal Type)
Series
Series MQM
MQM
ø6, ø10, ø16, ø20, ø25
ds
e
e
p
w s eds
o
l
d
e
ow friction cylinder for uniform an igh sp
l
t
c
a
p
to h
- Com
w
o
Q
l
resisting low friction cylinder for
MQ Lateral load
MQ
M
Low Friction Cylinder (Metal Seal Type)
Series MQQ /ø10, ø16, ø20, ø25, ø28
Series MQM /ø6, ø10, ø16, ø20, ø25
Metal seal construction with low operating resistance allows actuation in speed
Rod: Carbon steel (chrome plated)
Sleeve: Special stainless steel
(metal seal)
(metal seal)
Piston: Special stainless steel
(metal seal)
Lateral load resistance increased by built-in ball bushing
Patented floating mechanism facilitates stable operating
∗ MQQT type made of fluororesin.
resistance without galling due to shaft slippage.
Low breakaway pressure Long life
Minimal operating resistance allows low pressure
actuation at 0.005MPa.
Long life of 10,000km or 100 million full cycles.
∗ Contact SMC regarding vacuum applications.
Low friction
Low & uniform speed
actuation
Low operating resistance and high stability allow
force control as low as 0.05N.
(Based on cylinder Piston area x Pressure accuracy)
Smooth, uniform speed actuation ranges as low as
0.3mm/s.
No increased operating resistance after periods
of non-operation.
Series Variations
Series MQQ
Compact low friction cylinders designed for low pressure, low speed, uniform speed or low
friction applications
Series
MQQT
Standard type
MQQL
Lateral load resisting type
(built-in ball bushing)
Bore size
(mm)
10 20
Stroke (mm)
30 40 50 60 75 100
10
16
20
25
28
Operating pressure Actuation speed
range (MPa)
(mm/s)
0.005 to 0.5
0.3 to 300
0.005 to 0.7
0.5 to 500
Series MQM
Lateral load resisting low friction cylinders for low pressure, low speed, uniform speed,
low friction high pressure, high speed and high speed response (high frequency) actuation
Series
Bore size
(mm)
6 (standard only)
10
16
MQMLH
20
High speed/frequency
25
MQML
Standard type
Features 1
15
30
Stroke (mm)
45
60
75
100
Operating pressure Actuation speed
range (MPa)
(mm/s)
ø6: 0.02 to 0.7 0.5 to 1000
ø10 to ø25: 0.005 to 0.7
0.01 to 0.7
5 to 3000
High speed,
high frequency actuation
Application examples
Pressure control with
fine pressure variations
Applicable models: MQQT/MQML
H type achieves speeds up to 3,000mm/s (without fixed orifice),
and continuous actuation up to 50 cpm. (MQMLH)
Scrubber
Wafer
and output control ranges impossible for ordinary cylinders.
Lateral load
resistance
Polishing of wafers
Cutting of glass and lenses,
requiring constant force
Tension control responding
to very low pressure and
minute pressure variations
Applicable models: MQQL/MQML
Applicable models: MQQL/MQML
Coil
Lateral load resistance is
increased by a built-in ball bushing.
(MQQL/MQML)
Constant load
Winding
Capable of minute
strokes as short as
0.1mm
Glass
Cutting of
wavy surfaces
Coil winding
Transfer of precision
components, etc., that require
low or uniform speed actuation
Elimination of non-conforming
articles requiring high speed
actuation
Punching operations requiring
high frequency actuation
Applicable models: MQQT/MQML
Applicable models: MQML/MQMLH
Applicable models: MQML/MQMLH
Conveyor belt
Conveyor belt
High speed actuation
Thin plate
Soldering
machine
Nonconforming
article
Precision
component
Transfer of
precision components
Elimination of
non-conforming articles
Punching
Recommended circuit examples
Example 1) Uniform & low speed actuation (no control of cylinder output)
Precision
restrictors
Example 2) Low speed with output control
Solenoid valve
ITV (Electro-pneumatic regulator)
Mist separator
(0.01µm or less) (0.3µm or less)
Mist separator
(0.3µm or less)
W
IR
Air filter
(Precision regulator) (5µm or less)
∗ When using a solenoid valve, use a metal seal type (series VQ, VQZ, SQ, etc.).
Example 3) High speed & high frequency actuation
Solenoid valve
Air filter
(5µm or less)
∗ When using a solenoid valve, use a metal seal type (series VQ, VQZ, SQ, etc.).
W
IR
(Precision regulator)
Air filter
(5µm or less)
∗ When performing control of cylinder output, do not create a restriction
circuit using a speed controller, etc. Pressure inside the cylinder will drop
and control will become impossible. Always control actuation by means of
pressure control.
Applications based on low friction specification
1) Operating resistance will vary with an offset load. Be sure to properly align
the rod axis with the load and direction of movement when connecting.
When an offset load is expected, provide a suitable mechanism such as a
floating joint.
2) Use clean air (atmospheric pressure dew point temperature -10°C or less).
Use of a series AM mist separator (filtration rating of 0.3µm or less), or
series AM + AMD (filtration rating of 0.01µm or less) is recommended.
Features 2
Compact Low Friction Cylinder
Series MQQ
Metal Seal
ø10, ø16, ø20, ø25, ø28
How to Order
MQQ T B 10
Compact low friction
specification
T
L
10 D
Body option
Nil
M Note)
Type
Standard type
Lateral load resisting type
(built-in ball bushing)
Action
Standard (rod end female thread)
Rod end male thread
Note) A rod end thread adapter is attached.
Double acting
D
Cylinder stroke
Mounting
B
L
F
G
D Note)
Through hole & double end tapped (standard)
Foot type
Front flange type
Rear flange type
Double clevis type
Bore size
10
16
20
25
28
Bore size (mm)
10mm
16mm
20mm
25mm
28mm
Note) Available only for MQQL첸.
Standard stroke (mm)
10
10, 20, 30, 40
16
10, 20, 30, 40, 50, 60
20
10, 20, 30, 40, 50, 60
25
10, 20, 30, 40, 50, 75, 100
28
10, 20, 30, 40, 50, 75, 100
∗ Strokes are available in 1mm increments by installing spacers in
standard stroke cylinders.
∗ Mounting brackets are included when shipped,
but are not assembled.
∗ Series MQQ is not auto switch capable.
Mounting Bracket Part Numbers
Bore size (mm)
Foot Note 1)
Flange
Double clevis
Rod end thread adapter (with nut)
10
CQS-L016
CQS-F016
CQS-D016
MQ10-M
16
CQS-L020
CQS-F020
CQS-D020
MQ16-M
20
CQS-L025
CQS-F025
CQS-D025
MQ20-M
25
CQ-L032
CQ-F032
CQ-D032
MQ25-M
28
CQ-L040
CQ-F040
CQ-D040
MQ28-M
Note 1) When ordering foot brackets, order 2 pcs. for each cylinder.
Note 2) The following parts are included with the respective brackets.
Foot, Flange …………… Body mounting bolts
Double clevis …………… Clevis pin, C type snap ring for shaft, Body mounting bolts
1
Compact Low Friction Cylinder
Metal Seal
Series
MQQ
Specifications/Standard Type: MQQT
10
Bore size (mm)
16
20
25
28
Metal seal
Seal construction
Double acting single rod
Action
Air
Fluid
1.05MPa
Proof pressure
0.5MPa
Maximum operating pressure
Minimum operating pressure Note 1)
0.005MPa
–10 to 80°C
Ambient and fluid temperature
Rubber bumper (standard)
Cushion
Lubrication Note 2)
Not required (non-lube)
Rod end thread
Female thread
JIS class 2
Rod end thread tolerance
+1.0
0
Stroke length tolerance
0.3 to 300mm/s (Refer to page 23.)
Piston speed Note 3)
Supply pressure 0.1MPa 150cm³/min or less 200cm³/min or less
300cm³/min or less
Total
1200cm³/min or less
allowable Supply pressure 0.3MPa 800cm³/min or less 1000cm³/min or less
leakage Supply pressure 0.5MPa 1500cm³/min or less 2000cm³/min or less
3000cm³/min or less
Note 1) Use clean, dry air with no freezing.
Note 2) Refer to precautions on page 21 regarding lubrication.
Note 3) Control low speed actuation with differential pressure and a speed controller, etc.
(Refer to recommended circuit examples for further details.)
Symbol
Double acting: Single rod
Specifications/Lateral Load Resisting Type: MQQL
10
Bore size (mm)
16
Seal construction
Action
1.05MPa
Maximum operating pressure
0.7MPa
Minimum operating pressure Note 1)
0.005MPa
Ambient and fluid temperature
–10 to 80°C
Cushion
Rubber bumper (standard)
Lubrication Note 2)
Not required (non-lube)
Rod end thread
Female thread
Rod end thread tolerance
JIS class 2
+1.0
0
Stroke length tolerance
Piston speed
Unit: g
10
16
20
25
28
Cylinder stroke (mm)
10
94
166
228
395
661
20
118
206
290
487
799
30 40 50
142 166 —
246 286 326
352 414 476
579 671 763
937 1075 1213
60 75 100
— — —
366 — —
538 — —
— 993 1223
— 1558 1903
Weights/Lateral Load Resisting Type:
MQQL (Built-in Ball Bushing)
Unit: g
Bore
size
(mm)
10
16
20
25
28
Cylinder stroke (mm)
10 20 30 40 50
148 172 196 220 —
284 324 364 404 444
383 445 507 569 631
552 644 736 828 920
965 1103 1241 1379 1517
60 75 100
— —
—
484 —
—
693 —
—
— 1150 1380
— 1862 2207
28
Air
Proof pressure
Bore
size
(mm)
25
Double acting single rod
Fluid
Weights/Standard Type: MQQT
20
Metal seal
Note 3)
0.5 to 500mm/s (Refer to page 23.)
300cm³/min or less
Supply pressure 0.1MPa 150cm³/min or less 200cm³/min or less
Total
allowable Supply pressure 0.3MPa 800cm³/min or less 1000cm³/min or less
1200cm³/min or less
leakage
3000cm³/min or less
Supply pressure 0.5MPa 1500cm³/min or less 2000cm³/min or less
Note 1) Use clean, dry air with no freezing.
Note 2) Refer to precautions on page 21 regarding lubrication.
Note 3) Control low speed actuation with differential pressure and a speed controller, etc.
(Refer to recommended circuit examples for further details.)
Theoretical Output
OUT
Bore
size
(mm)
10
16
20
25
28
IN
Rod
Piston
size Direction area
(mm)
(mm ²)
0.1
IN
5.0
0.2
10.1
0.3
15.1
0.4
20.1
0.5
25.2
0.6
30.2
6
8
10
12
16
50.3
Unit: N
Operating pressure (MPa)
0.7
35.2
OUT
78.5
7.9
15.7
23.6
31.4
39.3
47.1
55.0
IN
145.8
14.9
29.2
43.7
58.3
72.9
87.5
102.1
OUT
196.1
19.6
39.2
58.9
78.4
98.1
117.7
137.3
IN
235.6
23.6
47.1
70.7
94.2
117.8
141.4
164.9
OUT
314.2
31.4
62.8
94.3
125.7
157.1
188.5
219.9
IN
377.8
37.8
75.6
113.3
151.1
188.9
226.7
262.5
OUT
490.9
49.1
98.2
147.3
196.4
245.5
294.5
343.6
IN
423.5
42.4
84.7
127.1
169.4
211.8
254.1
296.5
OUT
624.6
62.5
124.9
187.4
249.8
312.3
374.8
437.2
2
Series
MQQ
Construction
Standard type/MQQT
Lateral load resisting type/MQQL (built-in ball bushing)
Parts list
No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
3
Description
Rod
Material
Note
Carbon steel
Hard chrome plated
Piston
Special stainless steel
Liner
Special stainless steel
Sleeve
Special stainless steel
Sleeve retainer
Aluminum alloy
Plate
Aluminum alloy
Guide
Fluororesin
Cylinder tube
Bumper A
Bumper B
Aluminum alloy
Hard anodized
Polyurethane
Polyurethane
Bushing
Aluminum alloy
Bottom plate
Aluminum alloy
O-ring
Hard anodized
Hard anodized
NBR
Retaining ring
Carbon tool steel
Nickel plated
Bolt
Carbon tool steel
Nickel plated
Ball bushing
Compact Low Friction Cylinder
Metal Seal
Series
MQQ
Mounting
Mounting bolts
a) A type mounting (when using the mounting plate threads)
Use a flat washer.
C
C
D
D
Note) Be sure to use a flat washer for the A type mounting.
b) B type mounting (when using the cylinder tube threads)
E
t
t
E
Compatible mounting bolt dimensions
A type mounting
Model
Standard type
MQQT
Lateral load
resisting type
MQQL
(built-in ball bushing)
Mounting bolt size
MQQTB10-D
MQQTB16-D
MQQTB20-D
MQQTB25-D
MQQTB28-D
MQQLB10-D
MQQLB16-D
MQQLB20-D
MQQLB25-D
MQQLB28-D
M3 x 0.5
M5 x 0.8
M3 x 0.5
M5 x 0.8
C (mm)
B type mounting
D: Bolt length (mm)
Mounting bolt size
E (mm)
7
35 + Stroke
M4 x 0.7
8 to 11
7
35 + Stroke
8.5
40 + Stroke
M6 X 1
13 to 17
9
45 + Stroke
7.5
50 + Stroke
7
65 + Stroke
M4 x 0.7
8 to 11
5.5
70 + Stroke
M6 x 1
13 to 17
8
80 + Stroke
6.5
85 + Stroke
7
105 + Stroke
: Stroke
4
Series
MQQ
Dimensions
Standard type (through hole and double end tapped)/MQQTB
ø10, ø16, ø20
H effective thread depth C
2-M5 x 0.8
2 x 4-OA effective depth RA
2 x 4-øOB
Depth of counter bore RB
Y
F
Q
4-øN through
øD
E
M ±0.2
øI
K
M
L
B + Stroke
±0.2
A + Stroke
E
ø25, ø28
H effective thread depth C
2-Rc 1/8
Y
2 x 4-OA effective depth RA
F
Q
J
2 x 4-øOB
Depth of counter bore RB
4-øN through
øD
W
E
M ±0.2
øI
K
B + Stroke
L
M ±0.2
A + Stroke
E
(mm)
Bore size
(mm)
Stroke range
(mm)
10
10 to 40
16
10 to 60
20
10 to 60
47.5 37.5
A
B
N
OA
OB
Q
20
3.5
M4 x 0.7
6.5
14.5
25.5
5.4
M6 x 1.0
9
18
10
28
5.4
M6 x 1.0
9
19.5
10
12
34
5.5
M6 x 1.0
9
14
12
40
5.5
M6 x 1.0
9
C
D
E
F
H
I
J
K
39.5 31.5
6
6
29
5.5
M3 x 0.5
38
—
5
8
44
8
8
36
5.5
M4 x 0.7
47
—
7
10
10
10
40
5.5
M5 x 0.8
52
—
8
12
12
45
8.5
M6 x 1.0
60
4.5
13
16
52
8.5
M8 x 1.25
69
5
34
25
10 to 50, 75, 100 54
28
10 to 50, 75, 100 60.5 48.5
42
L
M
With rod end male thread/MQQ DM
Rod end nut∗
H1
(mm)
Bore size
(mm)
Rod end thread adapter∗
C1
X
L1
L1
C1
H1
X
10
23.5 10.5
M5 x 0.8
15.5
16
26.5 11.5
M6 x 1.0
16.5
20
28.5 13.5
M8 x 1.25 18.5
25
34.5 16.5 M10 x 1.25 22.5
28
40.5 22.5
M14 x 1.5 28.5
∗ Refer to page 9 for details regarding the rod
end thread adapter and rod end nut.
5
RA
RB
W
Y
7
4
–
5
10
7
–
5
10
7
–
6
23
10
7
49.5
26
10
7
57
7
10
Compact Low Friction Cylinder
Metal Seal
Series
MQQ
Foot type/MQQTL
ø10, ø16, ø20
(mm)
Bore size
(mm)
Stroke range
(mm)
A
B
10
10 to 40
44.3
16
10 to 60
51.2
LS + Stroke
20
10 to 60
A + Stroke
25
28
LY
XY
4-øLD
LX
LZ
ø25, ø28
L
YX
LT
LH
Special cap bolt
B + Stroke
L
LG
LD
LG
LH
31.5
8
4.5
2.8
19
34
10
6.6
4
24
54.7
37.5
10
6.6
4
26
10 to 50,75,100
61.2
42
12
6.6
4
30
10 to 50,75,100
67.7
48.5
12
6.6
4
33
LH
LY
B + Stroke
YX
LT
XY
4-øLD
LX
L
LG
LS + Stroke
LZ
Bore size
(mm)
LS
10
16
LT
LX
LY
LZ
19.5
2
38
33.5
48
8
5
22
3.2
48
42
62
9.2
5.8
20
22.5
3.2
52
46
66
10.7
5.8
25
26
3.2
57
57
71
11.2
5.8
28
32.5
3.2
64
64
78
11.2
7
X
Y
A + Stroke
Front flange type/ MQQTF
ø10, ø16, ø20
FV
(mm)
FX
FT
FZ
L B + Stroke
A + Stroke
2-øFD
FX
FZ
L
4-øFD
FD
FT
FV
FX
10
10 to 40
49.5
31.5
4.5
5.5
30
45
16
10 to 60
54
34
6.6
8
39
48
20
10 to 60
57.5
37.5
6.6
8
42
52
25
10 to 50,75,100 64
42
5.5
8
48
56
28
10 to 50,75,100 70.5
48.5
5.5
8
54
62
M
10
55
18
—
16
60
20
—
FT
20
64
20
—
B + Stroke
25
65
22
34
28
72
22
40
ø25, ø28
4-øFD
M
FV
(mm)
FV
A + Stroke
FT
B
L
2-øFD
L B + Stroke
A
FZ
A + Stroke
Rear flange type/MQQTG
ø10, ø16, ø20
Stroke range
(mm)
Bore size
(mm)
FV
M
ø25, ø28
Bore size
(mm)
Bore size
(mm)
Stroke range
(mm)
A
L
10
10 to 40
45
8
FX
FX
16
10 to 60
52
10
FZ
FZ
20
10 to 60
55.5
10
25
10 to 50,75,100
62
12
28
10 to 50,75,100
68.5
12
(Dimensions other than A and L are the
same as the front flange type.)
6
Series
MQQ
Dimensions
Lateral load resisting type (through hole and double end tapped)/MQQLB
ø10, ø16, ø20
H effective thread depth C
2 x 4-øOB
2-M5 x 0.8
2 x 4-OA effective depth RA
Y
F
Q
Depth of counter bore RB
4-øN through
øD
E
M ±0.2
øI
K
B + Stroke
L
M ±0.2
A + Stroke
E
ø25, ø28
H effective thread depth C
2-Rc 1/8
2 x 4-OA effective depth RA
Y
F
Q
J
2 x 4-øOB
Depth of counter bore RB
4-øN through
øD
W
E
M ±0.2
øI
K
B + Stroke
L
M ±0.2
A + Stroke
E
(mm)
Bore size
(mm)
Stroke range
(mm)
A
B
10
10 to 40
69.5
16
10 to 60
80.5
20
10 to 60
89
25
10 to 50, 75, 100
96.5
28
10 to 50, 75, 100 116
F
H
I
J
K
29
9
M3 x 0.5
38
—
5
8
36
11.5
M4 x 0.7
47
—
7
10
10
40
12
M5 x 0.8
52
—
8
10
12
12
45
13.5
M6 x 1.0
60
4.5
10
13
16
52
17.5 M8 x 1.25
69
5
14
C
D
E
61.5
6
6
70.5
8
8
79
10
84.5
104
N
OA
OB
Q
20
3.5
M4 x 0.7
6.5
25.5
5.4
M6 x 1.0
9
28
5.4
M6 x 1.0
12
34
5.5
12
40
5.5
L
M
With rod end male thread/MQQ DM
Rod end nut∗
H1
(mm)
Bore size
(mm)
Rod end thread adapter∗
C1
H1
X
10
23.5 10.5
M5 x 0.8
15.5
16
26.5 11.5
M6 x 1.0
16.5
C1
20
28.5 13.5
M8 x 1.25
18.5
X
25
34.5 16.5 M10 x 1.25 22.5
L1
7
L1
28
40.5 22.5 M14 x 1.5 28.5
∗ Refer to page 9 for details regarding the rod
end thread adapter and rod end nut.
RA
RB
W
Y
39.5
7
4
—
5
48.5
10
7
—
5
9
55
10
7
—
6
M6 x 1.0
9
58
10
7
49.5
M6 x 1.0
9
71
10
7
57
7
10
Compact Low Friction Cylinder
Metal Seal
Foot type/MQQLL
ø10, ø16, ø20
LT
LH
LY
4-øLD
XY
YX
LX
LS + Stroke
LZ
A + Stroke
LG
LY
LT
LH
XY
4-øLD
YX
LX
LS + Stroke
LZ
A + Stroke
LG
Front flange type/MQQLF
ø10, ø16, ø20
Stroke range
(mm)
A
B
10
10 to 40
74.3
16
10 to 60
87.7
20
10 to 60
96.2
L
LD
LG
LH
61.5
8
4.5
2.8
19
70.5
10
6.6
4
24
79
10
6.6
4
26
84.5
12
6.6
4
30
12
6.6
4
33
25
10 to 50, 75, 100 103.7
28
10 to 50, 75, 100 123.2 104
Bore size
(mm)
LS
10
16
LT
LX
LY
LZ
49.5
2
38
33.5
48
8
5
58.5
3.2
48
42
62
9.2
5.8
20
64
3.2
52
46
66
10.7
5.8
25
68.5
3.2
57
57
71
11.2
5.8
28
88
3.2
64
64
78
11.2
7
FV
Bore size
(mm)
FT
L
FZ
2-øFD
X
Y
B + Stroke
FV
FT
FX
L
FZ
A
B
FD
FT
FV
FX
10
79.5
61.5
4.5
5.5
30
45
16
10 to 60
90.5
70.5
6.6
8
39
48
20
10 to 60
99
79
6.6
8
42
52
5.5
8
48
56
5.5
8
54
62
28
ø25, ø28
Stroke range
(mm)
10 to 40
25
A + Stroke
M
Bore size
(mm)
(mm)
FX
10 to 50, 75, 100 106.5 84.5
10 to 50, 75, 100 126 104
Bore size
(mm)
FZ
L
M
10
55
18
—
16
60
20
—
20
64
20
—
25
65
22
34
28
72
22
40
B + Stroke
A + Stroke
4-øFD
(mm)
Rear flange type/MQQLG
ø10, ø16, ø20
ø25, ø28
4-øFD
FX
FT
A + Stroke
M
FX
FZ
FZ
FV
FV
2-øFD
L B + Stroke
(mm)
B + Stroke
L
ø25, ø28
MQQ
Special cap bolt
B + Stroke
L
Series
Bore size
(mm)
Stroke range
(mm)
10
10 to 40
75
16
10 to 60
88.5
10
10 to 60
97
10
20
A
L
8
25
10 to 50, 75, 100 104.5
12
28
10 to 50, 75, 100 124
12
(Dimensions other than A and L are the
same as the front flange type.)
(mm)
Double clevis type/MQQLD
Special cap bolt
CU
øCD hole H10
Shaft d9
+0.4
CT
L
B + Stroke
CL + Stroke
A + Stroke
CX +0.2
-0.1
CW
CZ -0.3
RR
Bore size
(mm)
Stroke range
(mm)
10
16
20
A
B
CD
CL
CT
CU
10 to 40
90.5
61.5
5
84.5
4
10
10 to 60
107.5
70.5
8
98.5
5
12
10 to 60
119
79
10
109
5
14
84.5
10
116.5
5
14
10
138
6
14
25
10 to 50, 75, 100 126.5
28
10 to 50, 75, 100 148
Bore size
(mm)
CW
10
15
6.5
16
18
8
20
20
25
28
CX
CZ
104
L
RR
12
8
6
16
10
9
10
20
10
10
20
18
36
12
10
22
18
36
12
10
8
Series
MQQ
Accessory Dimensions
Rod end thread adapter
Rod end nut
d
MM
NN
B
C
C
øD
Rod
H
E
F
H
B
A
Part no.
Applicable bore
size (mm)
A
B
C
D
E
F
Part no.
10
20.5
8
9.2
6
15.5
5
16
22.5
8
9.2
8
16.5
6
20
24.5
8
9.2
10
18.5
6
25
33.5
10
11.5
12
22.5
11
28
40.5
14
16
16
28.5
12
NTJ-015A
NT-015A
NT-02
NT-03
NT-04
Applicable bore
size (mm)
H
MM
NN
10
10.5
M5 x 0.8
M3 x 0.5
16
11.5
M6 x 1.0
M4 x 0.7
20
13.5
M8 x 1.25
M5 x 0.8
25
16.5
M10 x 1.25
M6 x 1.0
28
22.5
M14 x 1.5
M8 x 1.25
MQ10-M
MQ16-M
MQ20-M
MQ25-M
MQ28-M
Part no.
MQ10-M
MQ16-M
MQ20-M
MQ25-M
MQ28-M
Applicable bore
size (mm)
B
C
d
H
10
8
9.2
M5 x 0.8
4
16
10
11.5
M6 x 1.0
5
20
13
15
M8 x 1.25
5
25
17
19.6
M10 x 1.25
6
28
22
25.4
M14 x 1.5
8
m
l
m
t
L
t
øDd9
ød
Clevis pin part numbers
m
t
Applicable
snap ring
1.5
0.7
C type 5 for shaft
Part no.
Applicable bore
size (mm)
Dd9
L
d
l
IY-J015
10
5 -0.030
-0.040
16.6
4.8
12.2
IY-G02
16
-0.040
-0.076
21
7.6
16.2
1.5
0.9
C type 8 for shaft
IY-G03
20
10 -0.040
-0.076
25.6
9.6
20.2
1.55
1.15
C type 10 for shaft
IY-G04
25, 28
10 -0.040
-0.076
41.6
9.6
36.2
1.55
1.15
C type 10 for shaft
9
8
10
Lateral Load Resisting Compact Low Friction Cylinder
Series MQM
Metal Seal
ø6, ø10, ø16, ø20, ø25
How to Order
MQML B 10
15 D
Action
Lateral load resisting low
friction specification
D Double acting
Type
Cylinder stroke
Lateral load resisting type
(built-in ball bushing)
L
Mounting
B
L
F
G
C Note)
D
Standard stroke (mm)
Bore size (mm)
Standard type
Foot type
Front flange type
Rear flange type (except ø6)
Single clevis type (non-integrated type)
Double clevis type
6
15, 30, 45, 60
10
15, 30, 45, 60, 75, 100
16
15, 30, 45, 60, 75, 100
20
15, 30, 45, 60, 75, 100
25
15, 30, 45, 60, 75, 100
∗ Strokes are available in 1mm increments by installing spacers in standard
stroke cylinders.
Function
Note1) Bore size: 20, 25mm only
Standard type
High speed/high frequency type (without fixed orifice)
Nil
H Note)
∗ Mounting brackets are included when shipped,
but are not assembled. (Except clevis types.)
Note) Except 6mm bore size.
Note 2) ø6, ø10, ø16 ...... Integrated type
ø20, ø25 ............ Non-integrated type
Bore size
6
10
16
20
25
∗ Series MQM is not auto switch capable.
6mm
10mm
16mm
20mm
25mm
Mounting Bracket Types and Accessories
B: Standard
L: Foot
F: Front flange
G: Rear flange
Mounting nut Note 1)
(1 pc.)
(2 pcs.)
(1 pc.)
(1 pc.)
—
—
Rod end nut
Clevis pin
—
—
—
—
—
T-bracket
—
—
—
—
—
Mounting bracket
Standard
Option
C: Single clevis D: Double clevis
Note
Note 2)
With pin
Note 1) Mounting nut is not included with integral clevis, single clevis and double clevis types.
Note 2) Pin and snap ring are packed with double clevis type.
Mounting Bracket Part Numbers
Foot Note 1)
Flange
CJK-L016B
CJK-F016B
16
CLJ-L016B
CLJ-F016B
—
—
CJ-T016B
20
CM-L020B
CM-F020B
CM-C020B
CM-D020B
—
25
CM-L032B
CM-F032B
CM-C032B
CM-D032B
—
Bore size (mm)
6
10
Note 1) Two foot brackets and one mounting nut are included.
Note 2) Clevis pin and snap ring are included in package.
Note 3) The T-bracket is applicable to the double clevis type (D).
11
Single clevis
Double clevis (with pin) Note 2)
—
—
—
—
T-bracket Note 3)
CJ-T010B
Lateral Load Resisting Low Friction Cylinder
Metal Seal
Series
MQM
Specifications
Bore size (mm)
6
10
Seal construction
16
Action
Fluid
25
Air
Proof pressure
Maximum operating pressure
Minimum Note 1)
operating
pressure
1.05MPa
0.7MPa
Standard type
0.02MPa
H (High speed/
High frequency type)
—
0.005MPa
0.01MPa
Ambient and fluid temperature
Cushion
-10 to 80°C
Rubber bumper (standard)
Not required (non-lube)
Lubrication Note 2)
Rod end thread tolerance
JIS class 2
+1.0
0
Stroke length tolerance
Standard type
Piston Note 3)
H (High speed/
speed
High frequency type)
Total
allowable
leakage
Symbol
Double acting: Single rod
20
Metal seal
Double acting single rod
0.5 to 1000mm/s (Refer to page 23.)
5 to 3000mm/s (Refer to page 23.)
—
Supply pressure 0.1MPa 150cm³/min or less 250cm³/min or less 300cm³/min or less
Supply pressure 0.3MPa 800cm³/min or less 1000cm³/min or less 1200cm³/min or less
Supply pressure 0.5MPa 1500cm³/min or less 2500cm³/min or less 3000cm³/min or less
Note 1) Use clean, dry air with no freezing.
Note 2) Refer to precautions on page 21 regarding lubrication.
Note 3) Control low speed actuation with differential pressure and a speed controller, etc.
(Refer to recommended circuit examples for further details.)
Weights/Standard Type, High Speed/High Frequency Type
Unit: g
Bore size
(mm)
6
10
16
20
25
Cylinder stroke (mm)
15
30
45
60
75
52.5
60.7
68.9
77.1
—
100
—
92.4
102.7
113.0
123.3
133.6
143.9
152.4
175.2
198.0
220.8
243.6
266.4
349.8
392.6
435.4
478.2
521.0
563.8
460.8
510.0
559.2
608.4
657.6
706.8
Theoretical Output
OUT
Piston
Bore Rod
size size Direction area
(mm²)
(mm) (mm)
IN
15.7
4
6
OUT
28.3
10
16
20
25
4
5
8
10
IN
Unit: N
Operating pressure (MPa)
0.1
1.6
0.2
3.2
0.3
4.7
0.4
6.3
0.5
7.9
0.6
9.4
0.7
11.0
2.8
5.7
8.5
11.3
14.2
17.0
19.8
IN
66.0
6.6
13.2
19.8
26.4
33.0
39.6
46.2
OUT
78.5
7.9
15.7
23.6
31.4
39.3
47.1
55.0
IN
181.4
18.1
36.3
54.4
72.6
90.7
108.8
127.0
OUT
201.1
20.1
40.2
60.3
80.4
100.6
120.7
140.8
IN
263.9
26.4
52.8
79.2
105.6
132.0
158.3
184.7
OUT
314.2
31.4
62.8
94.3
125.7
157.1
188.5
219.9
IN
412.3
41.2
82.5
123.7
164.9
206.2
247.4
288.6
OUT
490.9
49.1
98.2
147.3
196.4
245.5
294.5
343.6
12
Series
MQM
Construction
Parts list
No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
13
Description
Rod
Material
Note
Carbon steel
Hard chrome plated
Piston
Special stainless steel
Tube
Special stainless steel
Head cover
Aluminum alloy
Hard anodized
Rod cover
Aluminum alloy
Hard anodized
Sleeve
Seat
Special stainless steel
NBR
Bumper A
Polyurethane
Bumper B
Polyurethane
Bumper C
Nut
Polyurethane
Aluminum alloy
Ball bushing
O-ring
NBR
Carbon tool steel
Nickel plated
Rod end nut
Steel
Nickel plated
Mounting nut
Steel
Snap ring
Lateral Load Resisting Low Friction Cylinder
Metal Seal
Series
MQM
Dimensions
Standard type/MQMLB
Mounting nut∗
ø6
M12 x 1
Rod end nut∗
15
2-M5 x 0.8
ø11
ø4
ø1
3
M4 x 0.7
16
15
8
21
4.5
11
66 + Stroke
27.5
93.5 + Stroke
ø10, ø16, ø20, ø25
Mounting nut∗
Rod end nut∗
G1
G2
2-P
NN
øJ
øD
NA
øI
MM
A
N2
F
N1
S + Stroke
H
F
ZZ + Stroke
(mm)
Bore size
(mm)
A
D
10
15
16
15
20
25
F
G1
G2
4
8
15
6
28
18.5 16
M4 x 0.7
11
20
5
10
15
6
30
22
22
M5 x 0.8
12
21
18
8
13
25
8.5
40.5 31.5 28.5 M8 x 1.25
20.5
33
18
10
13
30
8.5
44.5 34.5 32
M10 x 1.25 20.5
38
H
I
J
MM
N1
N2
NN
P
S
ZZ
16
M12 x 1
M5 x 0.8
65
101
19.5
M14 x 1
M5 x 0.8
74
114
29
M20 x 1.5
Rc 1/8
97.5 151
32
M26 x 1.5
Rc 1/8
102.5 160
NA
∗ Refer to page 18 for details regarding the rod end nut and mounting nut.
14
MQM
Series
Refer to the standard type on
page 14 for other dimensions.
Dimensions
2.3
14
25
Foot type/MQMLL
ø6
33
42
2-ø5.5
6 9
66 + Stroke
75 + Stroke
93.5 + Stroke
18.5
X
LX
LZ
4-øLC
Y
S + Stroke
LS + Stroke
ZZ + Stroke
Z
(mm)
Bore size
(mm)
LC
LH
LS
LT
LX
LY
LZ
S
X
Y
Z
ZZ
10
5.5
14
83
2.3
33
25
42
65
6
9
19
108
16
5.5
18
92
2.3
42
30
54
74
6
9
21
119
20
6.8
25
137.5 3.2
40
40
55
97.5
8
20
20.5 166
25
6.8
28
142.5 3.2
40
47
55
102.5
8
20
24.5 175
20
Front flange type/MQMLF
ø6
2-ø5.5
2.3
33
42
27.5
FX
FZ
H
66 + Stroke
93.5 + Stroke
FY
ø10, ø16, ø20, ø25
2-øFC
FT
(mm)
Bore size
(mm)
FC
FT
FX
FY
FZ
H
S
ZZ
10
5.5
2.3
33
20
42
28
65
101
16
5.5
2.3
42
24
54
30
74
114
20
7
4
60
34
75
40.5
97.5 151
25
7
4
60
40
75
44.5 102.5 160
15
S + Stroke
ZZ + Stroke
Y
X
LT
LY
LH
ø10, ø16, ø20, ø25
Lateral Load Resisting Low Friction Cylinder
Metal Seal
Series
MQM
Refer to the standard type on
page 14 for other dimensions.
Dimensions
FY
Rear flange type/MQMLG (except ø6)
ø10, ø16, ø20, ø25
FX
FT
H
S + Stroke
FZ
2-øFC
Z + Stroke
ZZ + Stroke
(mm)
Bore size
(mm)
FC
FT
FX
FY
FZ
H
S
10
5.5
2.3
33
20
42
28
65
95.3 101
16
5.5
2.3
42
24
54
30
74
106.3 114
20
7
4
60
34
75
40.5
97.5 142
151
25
7
4
60
40
75
44.5 102.5 151
160
Z
ZZ
Single clevis type/MQMLC (ø20 and ø25 only)
ø20, ø25 (non-integrated type)
+0.058
0
øCI
ø9 hole H10
10
14
H
S + Stroke
Z + Stroke
-0.1
-0.2
30
9
ZZ + Stroke
(mm)
Bore size
(mm)
CI
H
20
24
40.5
97.5 168
177
25
30
44.5 102.5 177
186
S
Z
ZZ
16
Series
MQM
Refer to the standard type on
page 14 for other dimensions.
Dimensions
Double clevis type/MQMLD
ø6, ø10, ø16 (integrated type)
S + Stroke
H
øCDH9 +0.030
0
R
Z + Stroke
Clevis pin
(øCDd9 -0.030
-0.060 )
U
BB
NB
CX
+0.1
0
GB
TH
T-bracket
Refer to page 18 for
details.
TY
TX
TW
TV
2-øTC
ZZ + Stroke
(mm)
Bore size
(mm)
BB
CD
CX
GB
H
NB
R
S
U
Z
ZZ
6
12
3.3
3.3 17.5 27.5
22
5
70.5
8
106
117
10
12
3.3
3.3 19
28
24
5
65
8
101
112
16
18
5
6.6 24
30
30
8
74
10
114
128
T-bracket related dimensions Note)
Part no.
Applicable bore
size (mm)
TC
TH
TV
TW
TX
TY
CJ-T010B
6, 10
4.5
29
40
22
32
12
CJ-T016B
16
5.5
Note) Refer to page 18 for details.
35
48
28
38
16
ø20, ø25 (non-integrated type)
+0.058
ø9 hole H10 0
-0.040
Shaft d9 -0.076
øCI
25
10
14
S + Stroke
H
Z + Stroke
ZZ + Stroke
(mm)
Bore size
(mm)
CI
H
20
24
40.5
97.5 168
177
25
30
44.5 102.5 177
186
17
S
Z
ZZ
30
19
9
+0.2
+0.1
Lateral Load Resisting Low Friction Cylinder
Metal Seal
Series
MQM
Accessory Dimensions
Rod end nut
Mounting nut
d
C
C
d
B
H
B
H
Material: Carbon steel
Material: Carbon steel
Part no.
SNKJ-016B
SNLJ-016B
SN-020B
SN-032B
Applicable bore
size (mm)
B
C
d
H
Part no.
6, 10
17
19.6
M12 x 1
4
16
19
21.9
M14 x 1
5
20
26
30
M20 x 1.5
8
25
32
37
M26 x 1.5
8
NTJ-010A
NTJ-015A
NT-02
NT-03
Applicable bore
size (mm)
B
C
D
H
6, 10
7
8.1
M4 x 0.7
3.2
16
8
9.2
M5 x 0.8
4
20
13
15
M8 x 1.25
5
25
17
19.6
M10 x 1.25
6
T-bracket
TH
7
4-øTC
+0.2
0
TV
12
TX
TK
-0.1
TN -0.3
TU
øTD H10
TT
TY
TW
Part no.
CJ-010B
CJ-016B
Applicable bore
size (mm)
TC
TD
TH
TK
TN
TT
6, 10
4.5
3.3
29
18
3.1
2
16
5.5
5
35
20
6.4
2.3
TU
TV
TW
TX
TY
9
40
22
32
12
14
48
28
38
16
Clevis pin
L
l
t
t
m
ød
øD d9
m
Material: Stainless steel
Part no.
CD-J010
CD-Z015
CDP-1
Applicable bore
size (mm)
D
l
L
3
3.3
12.2
15.2
16
4.8
5
18.3
22.7
1.5
0.7
20, 25
8.6
9
19.2
25
1.75
1.15
6, 10
d
m
t
1.2
0.3
18
Series MQQ/MQM
Safety Instructions
These safety instructions are intended to prevent a hazardous situation and/or
equipment damage. These instructions indicate the level of potential hazard by a
label of "Caution", "Warning" or "Danger". To ensure safety, be sure to observe
ISO 4414 Note 1), JIS B 8370 Note 2) and other safety practices.
Caution : Operator error could result in injury or equipment damage.
Warning : Operator error could result in serious injury or loss of life.
Danger :
In extreme conditions, there is a possible result of serious injury or loss of life.
Note 1) ISO 4414: Pneumatic fluid power -- Recommendations for the application of equipment to transmission and control
systems
Note 2) JIS B 8370: General Rules for Pneumatic Equipment
Warning
1. The compatibility of pneumatic equipment is the responsibility of the person
who designs the pneumatic system or decides its specifications.
Since the products specified here are used in various operating conditions, their compatibility for the
specific pneumatic system must be based on specifications or after analysis and/or tests to meet your
specific requirements.
2. Only trained personnel should operate pneumatically operated machinery and
equipment.
Compressed air can be dangerous if an operator is unfamiliar with it. Assembly, handling or repair of
pneumatic systems should be performed by trained and experienced operators.
3. Do not service machinery/equipment or attempt to remove components until
safety is confirmed.
1. Inspection and maintenance of machinery/equipment should only be performed after confirmation of
safe locked-out control positions.
2. When equipment is to be removed, confirm the safety process as mentioned above. Cut the supply
pressure for this equipment and exhaust all residual compressed air in the system.
3. Before machinery/equipment is restarted, take measures to prevent shooting-out of cylinder piston rod,
etc. (Bleed air into the system gradually to create back-pressure.)
4. Contact SMC if the product is to be used in any of the following conditions:
1. Conditions and environments beyond the given specifications, or if product is used outdoors.
2. Installation on equipment in conjunction with atomic energy, railway, air navigation, vehicles, medical
equipment, food and beverages, recreation equipment, emergency stop circuits, press applications, or
safety equipment.
3. An application which has the possibility of having negative effects on people, property, or animals,
requiring special safety analysis.
19
MQQ/MQM
Actuator Precautions 1
Series
Be sure to read before handling.
Design
Design
1. There is a danger of sudden action by air cylinders if
sliding parts of machinery are twisted and changes
in force occur.
9. Consider the action when operation is restarted after
an emergency stop or abnormal stop.
Warning
In such cases, human injury may occur; e.g., by catching hands
or feet in the machinery, or damage to the machinery itself may
occur. Therefore, the machine should be adjusted to operate
smoothly and designed to avoid such dangers.
Warning
Design the machinery so that human injury or equipment
damage will not occur upon restart of operation. When the
cylinder has to be reset at the starting position, install safe
manual control equipment.
2. A protective cover is recommended to minimize the
risk of human injury.
If a driven object and moving parts of a cylinder pose a danger
of human injury, design the structure to avoid contact with the
human body.
3. Securely tighten all stationary parts and connected
parts so that they will not become loose.
Particularly when a cylinder operates with high frequency or is
installed where there is a lot of vibration, ensure that all parts
remain secure.
4. A deceleration circuit or shock absorber, etc., may
be required.
Selection
Warning
1. Confirm the specifications.
The products advertised in this catalog are designed according
to use in industrial compressed air systems. If the products are
used in conditions where pressure, temperature, etc., are out
of specification, damage and/or malfunction may be caused.
Do not use in these conditions. (Refer to specifications.)
Consult SMC if you use a fluid other than compressed air.
2. Intermediate stops
When a driven object is operated at high speed or the load is
heavy, a cylinder's cushion will not be sufficient to absorb the
shock. Install a deceleration circuit to reduce the speed before
cushioning, or install an external shock absorber to relieve the
shock. In this case, the rigidity of the machinery should also be
examined.
When intermediate stopping of the cylinder piston is performed
by a 3 position closed center type directional control valve, it is
not possible to maintain the stop position for an extended time
due to the construction of the metal seal cylinder.
5. Consider the possibility that operating pressure may
drop due to a power outage, etc.
1. Operate the piston within a range such that collision
damage will not occur at the stroke end.
2. When controlling cylinder output, do not create a
restricting circuit by using a speed controller, etc.
Pressure inside the cylinder will drop and control
will become impossible. Be sure to control actuation
through pressure control.
When a cylinder is used in a clamping mechanism, there is a
danger of work pieces dropping if there is a decrease in
clamping force due to a drop in circuit pressure caused by a
power outage, etc. Therefore, safety equipment should be
installed to prevent damage to machinery and human injury.
Suspension mechanisms and lifting devices also require
consideration for drop prevention.
Caution
Mounting
6. Consider a possible loss of power source.
Measures should be taken to protect against human injury and
equipment damage in the event that there is a loss of power to
equipment controlled by pneumatics, electricity or hydraulics,
etc.
7. Design circuitry to prevent sudden lurching of driven
objects.
When a cylinder is driven by an exhaust center type directional
control valve or when starting up after residual pressure is
exhausted from the circuit, etc., the piston and its driven object
will lurch at high speed if pressure is applied to one side of the
cylinder because of the absence of air pressure inside the
cylinder. Therefore, equipment should be selected and circuits
designed to prevent sudden lurching, because there is a
danger of human injury and/or damage to equipment when this
occurs.
8. Consider emergency stops.
Design so that human injury and/or damage to machinery and
equipment will not be caused when machinery is stopped by a
safety device under abnormal conditions, such as a power
outage or a manual emergency stop.
Caution
1. Be certain to align the rod axis with the load and
direction of movement when connecting.
When not properly aligned twisting may occur in the rod and
tube, and this may cause abrasion or galling on the inside of
the tube, and the surface of the bushings and rod, etc.
2. When an external guide is used, connect the rod end
and the load in such a way that there is no
interference at any point within the stroke.
3. Do not scratch or gouge the cylinder tube or sliding
parts of the piston rod by striking or grasping them
with other objects.
Cylinder bores are manufactured to precise tolerances, so that
even a slight deformation may cause faulty operation.
Moreover, scratches or gouges, etc., in the sliding part of the
piston rod may cause malfunction.
4. Prevent the seizure of rotating parts.
Prevent the seizure of rotating parts (pins, etc.) by applying
grease.
20
MQQ/MQM
Actuator Precautions 2
Series
Be sure to read before handling.
Air Supply
Mounting
Caution
Caution
5. Do not use equipment until you verify that it can
operate properly.
After mounting, repair or modification, etc., connect the air
supply and electric power, and then confirm proper mounting
by means of appropriate function and leak inspections.
6. Instruction manual
Mount and operate the product after thoroughly reading the
manual and understanding its contents.
Also, keep the manual where it can be referred to as needed.
Piping
1. Preparation before piping
Before piping is connected, it should be thoroughly blown out
with air (flushing) or washed to remove chips, cutting oil and
other debris from inside the piping.
2. Wrapping of sealant tape
When screwing together pipes and fittings, etc., be certain that
chips from the pipe threads and sealant material do not get
inside the piping.
Also, when sealant tape is used, leave 1.5 to 2 thread ridges
exposed at the end of the threads.
Wrapping
direction
po
se
ap
Sealant tape
pr
Install air filters near valves on their upstream side. The
filtration degree should be 5µm or less. Furthermore, when
controlling for low speed or controlled output, use clean air
(atmospheric pressure dew point temperature of –10°C).
Installation of mist separator series AM (filtration degree 0.3µm
or less) or series AM + AMD (filtration degree 0.01µm or less)
is also recommended.
2. Install an after-cooler, air dryer or water separator,
etc.
Air that contains excessive drainage can cause malfunction of
valves and other pneumatic equipment. To prevent this, install
an after-cooler, air dryer or water separator, etc.
3. Use the product within the range of specifications
for fluid and ambient temperature.
Caution
Ex
1. Install air filters.
Take measures to prevent freezing when used at 5°C or less,
since moisture in circuits can freeze and this may cause
malfunction.
Refer to the "Air Cleaning Equipment" catalog for details on
compressed air quality.
Operating Environment
Warning
1. Do not use in environments where there is a danger
of corrosion.
Refer to the construction drawings regarding cylinder materials.
2. Do not use in dusty locations or where water, oil,
etc., will splash on the equipment.
ox
.2
thr
ea
Maintenance
ds
Lubrication
Warning
1. Perform maintenance according to the procedures
indicated in the instruction manual.
Caution
1. Lubrication of non-lube type cylinder
Do not apply lubrication when controlling for low speed or
controlled output. If lubrication is applied, there may be
changes in operating resistance due to factors such as the
viscosity and surface tension of the oil. Also, use a metal seal
type when using solenoid valves for cylinder actuation. If a
rubber seal type is used, there may be an increase in
operating resistance due to grease sprayed from the main
valve.
Lubrication is also unnecessary for high speed actuation, but
in the event that lubrication is applied, use turbine oil class 1
(with no additives) ISO VG32. (Do not use spindle oil or
machine oil.)
If handled improperly, malfunction and damage of machinery
or equipment may occur.
2. Removal of equipment and supply/exhaust of
compressed air.
When equipment is removed, first check measures to prevent
dropping of driven objects and run-away of equipment, etc.
Then cut off the supply pressure and electric power, and
exhaust all compressed air from the system.
When machinery is restarted, confirm measures to prevent
lurching and proceed with caution.
Caution
1. Drain flushing
Air Supply
Warning
1. Use clean air.
Do not use compressed air containing chemicals, synthetic
oils containing organic solvents, salt or corrosive gases, etc.,
as it can cause damage or malfunction.
21
Remove drainage from air filters regularly. (Refer to
specifications.)
MQQ/MQM
Specific
Product Precautions 1
Be sure to read before handling.
Series
See pages 19 through 21 for safety instructions and actuator precautions.
Operation
Disassembly
1. When mounting, thoroughly flush out the connector
piping and be sure that dirt and chips, etc., do not
get inside the cylinder.
2. Install an air filter with a filtration degree of 5µm or
less on the air supply. Furthermore, when controlling
for low speed or controlled output, use clean air
(atmospheric pressure dew point temperature of
–10°C). Installation of a mist separator (filtration
degree 0.3µm or less) is also recommended.
3. Use a metal seal type when using solenoid valves for
cylinder actuation. If a rubber seal type is used,
there may be an increase in operating resistance
due to grease sprayed from the main valve.
4. Operate so that the load applied to the piston rod is
normally in the axial direction.
1. The component parts of the metal seal cylinder are
manufactured to precision tolerances, and therefore
cannot be disassembled.
Caution
Caution
In the event that a lateral load is unavoidable, do not exceed
the range of the allowable lateral load at the rod end (refer to
pages 23 and 24). (Use outside of the operating limits may
cause an adverse effect on the life of the unit through problems
such as looseness in the guide unit and a loss of precision.)
5. Take care not to scratch or gouge the sliding portion
of the rod. This may cause malfunction or shorten
the unit’s life.
6. When attaching a work piece to the end of the rod,
move the rod to the fully retracted position and use
the wrench flats at the end of the rod. Fasten the
work piece without applying a large amount of
torque to the rod.
7. Be certain to connect a load so that the rod axis is
aligned with the load and its direction of movement.
22
MQQ/MQM
Specific
Product Precautions 2
Be sure to read before handling.
Series
See pages 19 through 21 for safety instructions and actuator precautions.
Selection
Series MQQ
Caution
Operating Speed
Allowable Kinetic Energy
Load weight and maximum speed: MQQT/MQQL
Lateral load resisting type: MQQ
1000
500
100
10
16
20
25
28
50
Load weight W(N)
Allowable
kinetic energy (J)
Bore size (mm)
Example)
Driving a load of
15(N) using MQQ20
with a maximum
speed of 167(mm/sec)
0.006
0.010
0.022
0.044
0.080
(15)
10
ø28
5
ø25
ø20
1
ø16
0.5
ø10
0.3
50
100
(167)
300
500
MQQT: Standard type
MQQL: Lateral load resisting type
Maximum speed V(mm/s)
Note 1) When a load is attached to the rod end, adjust the speed so that the maximum speed is no more
than that shown in the graph for the corresponding load weight.
W
Mounting orientation: Horizontal
Operating pressure: 0.5MPa
Allowable Lateral Load at Rod End
Standard type: MQQTB
Lateral load resisting type: MQQLB/Built-in ball bushing
60
Maximum allowable lateral load W(N)
Maximum allowable lateral load W(N)
5
4
ø28
3
ø25
2
ø20
ø16
50
40
ø28
30
ø25
20
ø20
ø16
1
10
ø10
ø10
30
60
Stroke (mm)
75
100
30
60
75
100
Stroke (mm)
Note 1) The indicated allowable lateral load at the rod end is for rod end female thread.
Note 2) The allowable lateral load varies depending on the size of the load (the distance to the load's center of gravity). Contact SMC for further details.
23
MQQ/MQM
Specific
Product Precautions 3
Be sure to read before handling.
Series
See pages 19 through 21 for safety instructions and actuator precautions.
Selection
Series MQM
Caution
Operating Speed
Allowable Kinetic Energy
Load weight and maximum speed
Lateral load resisting type: MQML
1000
Bore size (mm)
Example)
Driving a load of
15(N) using MQM16
with a maximum
speed of 460(mm/sec)
500
6
10
16
20
25
100
Load weight W(N)
50
Allowable
kinetic energy (J)
0.015
0.059
0.161
0.386
0.597
(15)
10
5
ø25
ø20
1
ø16
0.5
ø10
ø 6
0.3
50
100
(460) 500
1000
3000
MQML: Standard type
MQMLH: High speed/High frequency type
Maximum speed V(mm/s)
Note 1) When a load is attached to the rod end, adjust the speed so that the maximum speed is no more
than that shown in the graph for the corresponding load weight.
W
Allowable Lateral Load at Rod End
Mounting orientation: Horizontal
Operating pressure: 0.5MPa
Allowable lateral load at rod end
Maximum allowable lateral load W(N)
12
10
ø25
8
ø20
6
4
2
ø16
ø10
ø6
30
60
75
100
Stroke (mm)
Note 1) The allowable lateral load varies depending on the size of
the load (the distance to the load's center of gravity).
Contact SMC for further details.
24
SMC'S GLOBAL MANUFACTURING, DISTRIBUTION AND SERVICE NETWORK
EUROPE
EUROPE
NORTH AMERICA
AUSTRIA
SMC Pneumatik GmbH
CZECH
SMC Czech s.r.o.
DENMARK
SMC Pneumatik A/S
FINLAND
SMC Pneumatiikka OY
FRANCE
SMC Pneumatique SA
GERMANY
SMC Pneumatik GmbH
HUNGARY
SMC Hungary Kft.
IRELAND
SMC Pneumatics (Ireland) Ltd.
ITALY
SMC Italia S.p.A.
NETHERLANDS
SMC Pnuematics BV.
NORWAY
SMC Pneumatics Norway A/S
POLAND
SMC Industrial Automation Polska Sp.z.o.o.
ROMANIA
SMC Romania s.r.l.
RUSSIA
SMC Pneumatik LLC.
SLOVAKIA
SMC Slovakia s.r.o.
SLOVENIA
SMC Slovenia d.o.o.
SPAIN/PORTUGAL
SMC España, S.A.
SWEDEN
SMC Pneumatics Sweden AB
SWITZERLAND
SMC Pneumatik AG.
UK
SMC Pneumatics (U.K.) Ltd.
CANADA
SMC Pneumatics (Canada) Ltd.
MEXICO
SMC Corporation (Mexico) S.A. de C.V.
USA
SMC Pneumatics, Inc.
ASIA
CHINA
SMC (China) Co., Ltd.
HONG KONG
SMC Pneumatics (Hong Kong) Ltd.
INDIA
SMC Pneumatics (India) Pvt. Ltd.
MALAYSIA
SMC Pneumatics (S.E.A.) Sdn. Bhd.
PHILIPPINES
SMC Pneumatics (Philippines), Inc.
SINGAPORE
SMC Pneumatics (S.E.A.) Pte. Ltd.
SOUTH KOREA
SMC Pneumatics Korea Co., Ltd.
TAIWAN
SMC Pneumatics (Taiwan) Co., Ltd.
THAILAND
SMC Thailand Ltd.
SOUTH AMERICA
ARGENTINA
SMC Argentina S.A.
BOLIVIA
SMC Pneumatics Bolivia S.R.L.
BRAZIL
SMC Pneumaticos Do Brazil Ltda.
CHILE
SMC Pneumatics (Chile) S.A.
VENEZUELA
SMC Neumatica Venezuela S.A.
OCEANIA
AUSTRALIA
SMC Pneumatics (Australia) Pty. Ltd.
NEW ZEALAND
SMC Pneumatics (N.Z.) Ltd.
1-16-4 Shimbashi, Minato-ku, Tokyo 105-0004, JAPAN
Tel: 03-3502-2740 Fax: 03-3508-2480
URL http://www.smcworld.com
© 2000 SMC CORPORATION All Rights Reserved
1st printing
December, 2000
D-SMC.L.A.
P-80 (N)
Specifications are subject to change without prior notice
and any obligation on the part of the manufacturer.
Printed in Japan.

advertisement