96000 Series Safety Information

96000 Series Safety Information
96000 Series
RF Reference Source
Safety Information
Introduction
This document supplies safety information for the 96000 Series RF Reference
Source (the Product).
How to Contact Fluke Calibration
To contact Fluke Calibration, call one of the following telephone numbers:
•
Technical Support USA: 1-877-355-3225
•
Calibration/Repair USA: 1-877-355-3225
•
Canada: 1-800-36-FLUKE (1-800-363-5853)
•
Europe: +31-40-2675-200
•
Japan: +81-3-6714-3114
•
Singapore: +65-6799-5566
•
China: +86-400-810-3435
•
Brazil: +55-11-3759-7600
•
Anywhere in the world: +1-425-446-6110
To see product information or download manuals and the latest manual
supplements, visit Fluke Calibration’s website at www.flukecal.com.
To register your product, visit http://flukecal.com/register-product.
PN 4421578
April 2014
©2014 Fluke Corporation. All rights reserved. Product specifications are subject to change without notice.
All product names are trademarks of their respective companies.
96000 Series
Safety Information
Safety Information
The safety and electrical symbols shown in the following table may appear on the
Product or in the Product documentation.
Symbols
Symbol
Symbol
Meaning

Risk of Danger. Important
information. See Manual.

Earth Terminal

Hazardous voltage. Risk of electric
shock.

Recycle

AC (Alternating Current)
IO
Power ON / OFF


2
Meaning
Intertek ETL listed mark for CSA
C22.2, 61010-1 and UL 61010-1



Conforms to relevant South Korean
EMC standards.
Conforms to European Union directives.
Conforms to relevant Australian EMC
standards
This product complies with the WEEE Directive (2002/96/EC) marking requirements. The
affixed label indicates that you must not discard this electrical/electronic product in domestic
household waste. Product Category: With reference to the equipment types in the WEEE
Directive Annex I, this product is classed as category 9 "Monitoring and Control
Instrumentation" product. Do not dispose of this product as unsorted municipal waste. Go to
Fluke’s website for recycling information.
RF Reference Source
Safety Information
A Warning identifies conditions and procedures that are dangerous to the user.
Warning
To prevent possible electrical shock, fire, or personal injury:
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Read all safety information before you use the Product.
Carefully read all instructions.
Use the Product only as specified, or the protection supplied by the
Product can be compromised.
Do not use the Product if it operates incorrectly.
Do not use the Product around explosive gas, vapor, or in damp or wet
environments.
Disable the Product if it is damaged.
Do not use the Product if it is damaged.
Use this Product indoors only.
Use only the mains power cord and connector approved for the voltage
and plug configuration in your country and rated for the Product.
Do not apply hazardous voltages to any connector other than the mains
supply to the mains input.
Make sure the ground conductor in the mains power cord is connected to
a protective earth ground. Disruption of the protective earth could put
voltage on the chassis that could cause death.
Replace the mains power cord if the insulation is damaged or if the
insulation shows signs of wear.
If the mains power cord is to be the accessible disconnect device, the
mains power cord must not be longer than 3 meters (118.1 inches).
Turn the Product off and remove the mains power cord. Stop for 2 minutes
to let the power assemblies discharge before you open the fuse door.
Do not operate the Product with covers removed or the case open.
Hazardous voltage exposure is possible.
Disconnect the mains power cord before you remove the Product covers.
Remove the input signals before you clean the product.
Use only specified replacement parts.
Use only specified replacement fuses.
Have an approved technician repair the Product.
Do not apply more than the rated voltage, between the terminals or
between each terminal and earth ground.
Use good lifting practices when lifting or moving the Product. The Product
is an unbalanced load and can weigh as much as 18 kg (40 pounds).
3
96000 Series
Safety Information
Safety Specifications
Voltage ................................................................... 100 V to 240 V rms with additional voltage
fluctuations ±10 %.
Frequency .............................................................. 50 Hz to 60 Hz with additional frequency variation of
±3 Hz.
Power Rating .......................................................... 250 VA.
Temperature
Operating................................................................ 0 °C to 50 °C
Specified Operation ................................................ 5 °C to 40 °C
Storage ................................................................... -20 °C to 70 °C
Warm Up ................................................................ 60 minutes
Relative Humidity (non-condensing) ...................... 5 °C to 30 °C <90 %, <40 °C <75 %, <70 °C <45 %
Altitude
Operating................................................................ < 2000 meters
Storage................................................................... <12000 meters
LIMITED WARRANTY AND LIMITATION OF LIABILITY
Each Fluke product is warranted to be free from defects in material and workmanship under normal use and service. The
warranty period is one year and begins on the date of shipment. Parts, product repairs, and services are warranted for 90
days. This warranty extends only to the original buyer or end-user customer of a Fluke authorized reseller, and does not
apply to fuses, disposable batteries, or to any product which, in Fluke's opinion, has been misused, altered, neglected,
contaminated, or damaged by accident or abnormal conditions of operation or handling. Fluke warrants that software will
operate substantially in accordance with its functional specifications for 90 days and that it has been properly recorded on
non-defective media. Fluke does not warrant that software will be error free or operate without interruption.
Fluke authorized resellers shall extend this warranty on new and unused products to end-user customers only but have no
authority to extend a greater or different warranty on behalf of Fluke. Warranty support is available only if product is
purchased through a Fluke authorized sales outlet or Buyer has paid the applicable international price. Fluke reserves the
right to invoice Buyer for importation costs of repair/replacement parts when product purchased in one country is
submitted for repair in another country.
Fluke's warranty obligation is limited, at Fluke's option, to refund of the purchase price, free of charge repair, or
replacement of a defective product which is returned to a Fluke authorized service center within the warranty period.
To obtain warranty service, contact your nearest Fluke authorized service center to obtain return authorization
information, then send the product to that service center, with a description of the difficulty, postage and insurance prepaid
(FOB Destination). Fluke assumes no risk for damage in transit. Following warranty repair, the product will be returned to
Buyer, transportation prepaid (FOB Destination). If Fluke determines that failure was caused by neglect, misuse,
contamination, alteration, accident, or abnormal condition of operation or handling, including overvoltage failures caused
by use outside the product’s specified rating, or normal wear and tear of mechanical components, Fluke will provide an
estimate of repair costs and obtain authorization before commencing the work. Following repair, the product will be
returned to the Buyer transportation prepaid and the Buyer will be billed for the repair and return transportation charges
(FOB Shipping Point).
THIS WARRANTY IS BUYER'S SOLE AND EXCLUSIVE REMEDY AND IS IN LIEU OF ALL OTHER WARRANTIES,
EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR
FITNESS FOR A PARTICULAR PURPOSE. FLUKE SHALL NOT BE LIABLE FOR ANY SPECIAL, INDIRECT,
INCIDENTAL, OR CONSEQUENTIAL DAMAGES OR LOSSES, INCLUDING LOSS OF DATA, ARISING FROM ANY
CAUSE OR THEORY.
Since some countries or states do not allow limitation of the term of an implied warranty, or exclusion or limitation of
incidental or consequential damages, the limitations and exclusions of this warranty may not apply to every buyer. If any
provision of this Warranty is held invalid or unenforceable by a court or other decision-maker of competent jurisdiction,
such holding will not affect the validity or enforceability of any other provision.
Fluke Corporation
P.O. Box 9090
Everett, WA 98206-9090
U.S.A.
11/99
4
Fluke Europe B.V.
P.O. Box 1186
5602 BD Eindhoven
The Netherlands
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising