Flowline EchoPod & EchoSonic DL Ultrasonic Liquid Level Specs

Flowline EchoPod & EchoSonic DL Ultrasonic Liquid Level Specs
Prices as of April 27, 2016. Check Web site for most current prices.
EchoPod® & EchoSonic® II
Ultrasonic Liquid Level Sensors
The EchoPod and EchoSonic II are innovative ultrasonic liquid
level sensor families that replace float, conductance and
pressure sensors that fail due to contact with dirty, sticky and
scaling media in small, medium and large capacity tanks.
Applied in chemical, water and wastewater applications, these
general purpose non-contact sensors are available with single
and multi-function capabilities including continuous level
measurement, switching and control.
For input to a PLC or other controller, measurement outputs
include current, voltage and frequency. Models with four
relays can be configured for level alarms and/or stand-alone
level control such as automatic fill or empty functions using
the embedded level controller. PC configuration is simple with
WebCal™ software.
Company
Information
Drives
Soft Starters
Motors
Power
Transmission
Motion: Servos
and Steppers
Motor Controls
Sensors:
Proximity
Sensors:
Photoelectric
Sensors:
Encoders
Sensors:
Limit Switches
Sensors:
Current
EchoPod & EchoSonic II Ultrasonic Liquid Level Sensors General Specifications
Model
DL34-00
DL24-00
DL14-00
DS14-00
DX10-00
DL10-00
LU27-00
LU23-00
LU28-00
LU29-00
Price
$539.00
$446.00
$353.00
$330.00
$279.00
$306.00
$497.00
$590.00
$683.00
$776.00
Type
EchoPod
EchoSonic II
Class
Range
Output Types
2 in to 4.1 ft (5 cm to 1.25m)
4-20 mA and (4) SPST relays
(4) SPST relays
Relays
4 in to 9.8 ft 8 in to 18 ft (20 8 in to 26.2 ft 8 in to 32.8 ft
(10 cm to 3m) cm to 5.5m) (20 cm to 8m) (20 cm to 10m)
0-5V, 0-10V,
976-2000 Hz
Install
Mounting
Sensors:
Temperature
General Purpose (non-hazardous)
8 in to 18 ft (20 4 in to 9.8 ft
cm to 5.5m) (10 cm to 3m)
1 in MNPT
Pushbuttons
and Lights
2 in MNPT
(4) SPST
Configuration
Ambient
Temperature
Process
Temperature
Pressure
No Relay
Stacklights
WebCal Software (free download) and LI99-1001 Fob USB Adapter (purchased separately)
Signal
Devices
-31° to 140°F (-35° to 60°C)
Process
20° to 140°F (-7° to 60°C)
-4° to 140°F (-20° to 60°C)
Relays and
Timers
30 PSI (2 bar) max.
Pneumatics:
Air Prep
WebCal Software
WebCal
LI99-1001
WebCal PC software is a utility program that allows users to easily configure their EchoSonic II and EchoPod level
transmitters, switches, and controllers. Download your free copy of WebCal at www.AutomationDirect.com, and
connect your sensor through our Fob USB adapter (LI99-1001). Develop your configuration using pre-programmed
function menus as the tank graphic and set point fields automatically change to match your configuration. Then,
input your level set point values and click the Write to Unit button. Your configuration will be downloaded into
the sensor and verified in less than a second. Last, click the Wiring Diagram button to open a wiring schematic of your configuration in PDF format. Print the document, disconnect the sensor and wire it per the schematic. As new software or firmware becomes available, they can be downloaded and updated through WebCal.
PodView®
LI40-1001
Sensors:
Level
Sensors:
Flow
4-20 mA
Vertical, top of tank
2 in MNPT
Sensors:
Pressure
The PodView digital level indicator is a low cost general purpose level indicator that displays engineering units for
level or volume and shares power with an EchoPod ultrasonic sensor, including loop powered devices. The LI40
can be field mounted for local indication as well as be used to make simple setting changes to the sensor. The
display can be easily attached to any EchoPod sensor that has been configured with WebCal 6.0 / firmware 50.0
or higher. PodView displays sensor output and can reconfigure sensor setpoints on the fly. PodView shares power
with the sensor and does not require any additional outside power supply.
Book 2 (14.3)
www.automationdirect.com/ultrasonic-level-sensors
Level Sensors
eLE-5
Pneumatics:
Directional Control
Valves
Pneumatics:
Cylinders
Pneumatics:
Tubing
Pneumatics:
Air Fittings
Appendix
Book 2
Terms and
Conditions
Prices as of April 27, 2016. Check Web site for most current prices.
EchoPod DL Series Multi-Function
Ultrasonic Liquid Level Sensors
Overview
Features
The EchoPod DL series multi-function ultrasonic liquid level sensors
provide continuous level measurement up to 4.1 ft (1.25m), 9.8 ft
(3m), or18 ft (5.5m), with a 4-20mA signal output and 4 programmable relays for level switch or level control functions, and are
configured via WebCal software. The embedded level controller
can lower cost by replacing external control hardware. This
non-contact liquid level sensor is ideally suited for corrosive, sticky
or dirty liquids, and is broadly selected for small day tank, skid,
intermediate bulk tanks, sump and process tank level applications.
Part No. DL24-00
Part No. DL34-00
• cFMus
DL14-00
DL24-00
$353.00
$446.00
$539.00
4 in to 9.8 ft (10 cm to 3m)
8 in to 18.0 ft (20 cm to 5.5m)
± 0.2% of range
0.019 in (0.5 mm)
0.039 in (1 mm)
0.079 in (2 mm)
2 in (5.1 cm)
4 in (10.2 cm)
8 in (20.3 cm)
2 in (5.1 cm)
3 in (7.6 cm)
2 in (5.1 cm)
WebCal Free Software and LI99-1001 Fob USB Adapter
Non-volatile
0.5W
4-20 mA or 20-4 mA
Sensors:
Photoelectric
Sensors:
Encoders
Sensors:
Limit Switches
Sensors:
Temperature
Sensors:
Level
Sensors:
Flow
Process
4 mA, 20 mA, 21 mA, 22 mA or hold last
(4) SPST relays
Relays and
Timers
0.5A @ 120 VAC/DC; 1A @ 30 VAC/DC
Power loss: Hold last; Echo loss: Open, close or hold last
Pneumatics:
Air Prep
Selectable
20° to 140°F (-7° to 60°C)
Pneumatics:
Directional Control
Valves
Automatic
-31° to 140°F (-35° to 60°C)
30 PSI (2 bar) MAX
Pneumatics:
Cylinders
NEMA Type 6P, IP67, encapsulated, corrosion resistant & submersible, UV stable
Polycarbonate
Pneumatics:
Tubing
Santoprene
Polyvinylidene Flouride
Pneumatics:
Air Fittings
Polyurethane
9-conductor, shielded
48 in (1.2m)
1 in MNPT (See accessories for installation fittings)
2 in MNPT (See accessories for installation fittings)
Viton (included, replacement part number 204038) Viton (included, replacement part number 200128)
Viton (included, replacement part number 200129)
1.8
General purpose
CE, RoHS
cFMus
If supply exceeds 28 VDC damage to the transmitter may occur.
www.automationdirect.com/ultrasonic-level-sensors
Sensors:
Proximity
Signal
Devices
4-20 mA, two-wire
* Dead band is the minimum distance the sensor must be mounted above the max liquid level.
1
Motor Controls
Stacklights
500Ω max @ 24 VDC
0.9
Motion: Servos
and Steppers
Pushbuttons
and Lights
14 - 28 VDC1
0.5
Power
Transmission
Sensors:
Pressure
DL34-00
2 in to 4.1 ft (5 cm to 1.25m)
0.125 in (3 mm)
Soft Starters
Sensors:
Current
DLx4 Series Technical Specifications
Model
Price
Range
Accuracy
Resolution
Sensing Dead Band*
Beam Width
Configuration
Memory
Loop Supply Voltage
Consumption
Loop Resistance
Signal Output
Signal Invert
Loop Fail-Safe
Contact Type
Contact Ratings
Contact Fail-Safe
Hysteresis
Process Temperature
Temp. Compensation
Ambient Temperature
Pressure
Enclosure Rating
Enclosure Material
Strain Relief Material
Transducer Material
Cable Jacket Material
Cable Type
Cable Length
Process Mount
Mount Gasket
Weight (lbs)
Classification
Compliance
Agency Approvals
Drives
Motors
• Switch and control functions with continuous level measurement
analog output up to 4.1 ft (1.25m), 9.8 ft (3m) or 18 ft (5.5m)
•Configuration is fast and easy via WebCal software and USB adapter
• Narrow beam width and short dead band optimized for small tanks
• 4-20 mA signal output and four programmable relays rated at
1A / 60VA for switch, pump or valve control and fail-safety
- 1 pump or valve with 3 alarms
- 2 pumps (lead-lag) with 2 alarms
- 2 pumps (duplexing) with 2 alarms
- 4 independent outputs
• PVDF transducer and NEMA Type 6P polycarbonate enclosure for
corrosive liquids, UV stable for outdoor use
• Automatic temperature compensation for accurate measurement
• Made in the USA
Agency Approvals
Part No. DL14-00
Company
Information
Book 2 (14.3)
Level Sensors
eLE-9
Appendix
Book 2
Terms and
Conditions
Prices as of April 27, 2016. Check Web site for most current prices.
EchoPod DL Series Multi-Function
Ultrasonic Liquid Level Sensors
Dimensions
inches [mm]
DL14-00
DL24-00
When installing the 1 inch NPT level sensors care should be used to mechanically isolate the sensor housing from the tank. This
can easily be done by using any of the Flowline mounting accessories which are designed to provide the isolation needed.
DL34-00
Configuration
The settings for the the DL series are configured with free
WebCal software (downloadable from AutomationDirect Web
site) and an LI99-1001 Fob USB adapter (purchased separately).
RED
GREEN
WHITE
BLACK
PART NO.: LI99-1001
See the end of the Ultrasonic Level Sensor Section for further details and
Accessories
Wiring
Red
Blk
Wht
Grn
Blu
Org
Yel
Pur
Brn
-
Power
Power Return or 4-20mA Loop Output
TX (Out)
RX (In)
Rly 1
Rly 2
Rly 3
Rly 4
Rly Com
Book 2 (14.3)
eLE-10
Level Sensors
1-800-633-0405
Prices as of April 27, 2016. Check Web site for most current prices.
PodView® Digital Level Indicator
Company
Information
Drives
Overview
Soft Starters
The PodView digital level indicator is a low cost general purpose indicator that
displays engineering units for level or volume when combined with an EchoPod
ultrasonic sensor that has been configured with WebCal 6.0 / firmware 50.0 or
higher. The LI40 can be field mounted for local indication as well as be used
to make simple setting changes to the sensor. PodView displays sensor output
and can reconfigure sensor set points on the fly without needing to connect to
a PC. PodView shares power with the EchoPod sensor and does not require any
additional separate power supply.
LI40-1001 Technical Specifications
Price
Display (Engineering Units)
Character Height
Linearization
Level or Volume
0.374 in (9.5 mm)
per sensor configuration
User Interface
Input
Three button
EchoPod sensor family
Memory
Non-volatile
Supply Voltage
12-28 VDC power shared with
sensor (EchoPod not to exceed
28 VDC)
Operating Temperature
-4°F to 140°F (-20°C to 60°C)
Cable Type
4-conductor, 22 AWG (0.33 mm²)
Cable Length
4 ft (1.2m)*
Cable Jack Material
Polyurethane
Enclosure Rating
Agency Approvals
Dimensions
Sensors:
Encoders
Sensors:
Limit Switches
Sensors:
Current
Sensors:
Pressure
Sensors:
Temperature
Stacklights
Signal
Devices
Silicon rubber
Process
General purpose
Relays and
Timers
0.6
CE, RoHS
Pneumatics:
Air Prep
* Maximum distance between EchoPod sensor and PodView
display is 15 ft (4.5m)
Pneumatics:
Directional Control
Valves
Configuration
The settings for the the EchoPod series are configured with
free WebCal software (downloadable from AutomationDirect
Web site) and an LI99-1001 Fob USB adapter (purchased
separately). To be compatible with PodView the EchoPod
sensor must be configured with WebCal 6.0 / firmware 50.0
or higher.
Sensors:
Photoelectric
Pushbuttons
and Lights
Panel
Button Material
Motor Controls
Sensors:
Flow
inches [mm]
Polycarbonate
Enclosure Mount
Motion: Servos
and Steppers
Sensors:
Level
• CE
NEMA 4 (IP65) faceplate
Enclosure Material
Classification
Weight (lbs)
Compliance
• Operates with all EchoPod level sensors compatible with WebCal 6.0 software /
firmware 50.0 or higher
• No separate power supply required
• Use PodView to make simple adjustments to EchoPods sensor settings
• Provides level indication up to 15 feet from sensor
• Corrosion resistant NEMA 4 / IP65 enclosure
• No configuration required for the display. Simply wire the display directly to a
programmed compatible EchoPod sensor
• Display can be transferred from sensor to sensor without any configuration changes to
the display
• Make quick setpoint changes without the need to connect sensor back to a PC
• Made in the USA
LCD, 6-digit with 4 relay
indicators
Display Type
Power
Transmission
Sensors:
Proximity
Features
$195.00
Motors
Pneumatics:
Cylinders
Wiring
Pneumatics:
Tubing
Red
4-20 mA
load
Pneumatics:
Air Fittings
Blk
if applicable
RED
GREEN
WHITE
BLACK
EchoPod®
Wht
Wht
Grn
Blu
Org
Yel
Pur
Brn
Grn
Appendix
Book 2
PodView®
PART NO.: LI99-1001
Note: M
aximum distance between EchoPod sensor
and PodView display is 15 ft. (4.5m)
See the WebCal software catalog page in this section for further details
Book 2 (14.3)
www.automationdirect.com/ultrasonic-level-sensors
Level Sensors
eLE-11
Terms and
Conditions
Prices as of April 27, 2016. Check Web site for most current prices.
WebCal Ultrasonic Level
Sensor Software and USB Fob
Adapter
Overview
System Requirements
WebCal PC software is a utility program that allows users to
easily configure their EchoSonic II and EchoPod level transmitters, switches, and controllers. Download your free copy
of WebCal at www.AutomationDirect.com, and connect your
sensor through the Fob USB adapter (LI99-1001). Develop your
configuration using pre-programmed function menus as the tank
graphic and set point fields automatically change to match your
configuration. Then, input your level set point values and click
the Write to Unit button. Your configuration will be downloaded
into the sensor and verified in less than a second. Last, click
the Wiring Diagram button to open a wiring schematic of your
configuration in PDF format. Print the document, disconnect the
sensor and wire it per the schematic. It’s that simple.
• Windows XP, Vista, 7, 8 (WebCal 6.0 only)
®
• 32 or 64 bit system
• 1 USB 2.0 Port
®
• 10 Mb hard disk space
• 256 Mb RAM
Features
Configuration files can be named, saved, emailed, printed,
opened and used again under revision control. The advanced
feature page enables you to change the measurement signal,
output filtering and invert relay states from N.O. to N.C. As
new software or firmware becomes available, they can be
downloaded and updated through WebCal.
• 169 configurations with pull-down menu selections
• Graphical interface lets you visualize your configuration
• Applicable level set point fields appear automatically
• Installs and tests configuration in less than a second
• Available PDF wiring diagram for each configuration
• Technical help menu with FAQs, tips and glossary
• Rapidly program sensors to the same configuration
• Save configuration files for future use or reference
• Print wiring diagrams and configuration text files
• Email configuration files to other remote users
• Made in the USA
WebCal Ultrasonic Level Sensor Software and USB Adapter
Part No.
Item Photo
Description
Quantity Weight (lbs)
Price
LI99-1001
Flowline Fob USB adapter, required for use with WebCal software to configure Flowline EchoPod and
EchoSonic II ultrasonic level sensors.
1
0.1
$42.00
WEBCAL
Configuration software CD for Flowline EchoPod and EchoSonic II ultrasonic level sensors (also available
as a free download from the AutomationDirect Web site). Requires an LI99-1001 Fob USB adapter (purchased separately).
1
0.1
$9.00
EchoPod Configuration
EchoSonic II Configuration
Book 2 (14.3)
eLE-14
Level Sensors
1-800-633-0405
Prices as of April 27, 2016. Check Web site for most current prices.
Ultrasonic Liquid Level Sensor
Accessories
Ultrasonic Liquid Level Sensor Accessories
Part No.
Item Photo
Description
Quantity
Weight
Price
LI40-1001
Flowline PodView general purpose digital indicator, displays tank level or volume and sensor relay status,
6-digit LCD display with four relay status indicators, 3-button user interface, polycarbonate panel mount
enclosure with NEMA 4 (IP65) faceplate, 6-foot (1.8-meter) 22AWG 4-conductor cable, compatible with
any Flowline EchoPod series ultrasonic level sensor with firmware V50 or later
1
0.6
$181.00
LM50-1001
Flowline side mount bracket, 2 inch NPT female threads, polypropylene (PP), for use with Flowline DL34,
LU20, LU23, LU28, LU29, LU74, LU78, LU81, LU83, and LU84 series ultrasonic level sensors
1
0.4
$32.00
LM50-1001-1
Flowline side mount bracket, 2 inch NPT female threads, polypropylene (PP), and 2 inch NPT male x 1
inch NPT female reducer bushing (PVC), for use with Flowline DL14, DL24, DS14, DL10, DX10, LU27,
LU77, and LU80 series ultrasonic level sensors
1
0.6
$41.00
LM52-1400
Flowline reducer bushing, 2 inch NPT male x 1 inch NPT female threads, PVC, for use with Flowline DL14,
DL24, DS14, DL10, DX10, LU27, LU77, and LU80 series ultrasonic level sensors
1
0.2
$13.00
LM52-2400
Flowline reducer bushing, 3 inch NPT male x 2 inch NPT female threads, PVC, for use with Flowline DL34,
LU20, LU23, LU28, LU29, LU74, LU78, LU81, LU83, and LU84 series ultrasonic level sensors
1
0.6
$29.00
LM52-1890
Flowline low-profile bulkhead fitting, 1 inch NPT female x slip socket, with mounting nut, PVC, for use with
Flowline DL14, DL24, DS14, DL10, DX10, LU27, LU77 and LU80 series ultrasonic level sensors
1
0.5
$41.00
LM52-2890
Flowline low-profile bulkhead fitting, 2 inch NPT female x slip socket, with mounting nut, PVC, for use
with Flowline DL34, LU20, LU23, LU28, LU29, LU74, LU78, LU81, LU83, and LU84 series ultrasonic level
sensors
1
1.2
$69.00
LM52-1850
Flowline mounting flange, 1 inch NPT female threads, PVC, for use with Flowline DL14, DL24, DS14,
DL10, DX10, LU27, LU77, and LU80 series ultrasonic level sensors
1
0.5
$41.00
LM52-2850
Flowline mounting flange, 2 inch NPT female threads, PVC, for use with Flowline DL34, LU20, LU23,
LU28, LU29, LU74, LU78, LU81, LU83, and LU84 series ultrasonic level sensors
1
1.0
$60.00
204038
Replacement mounting gasket, for use with Flowline DL14, DL10, DX10, and DS14 series ultrasonic level
sensors
1
0.1
$5.00
200128
Replacement mounting gasket, for use with Flowline DL24, LU27, LU77, and LU80 series ultrasonic level
sensors
1
0.1
$9.00
200129
Replacement mounting gasket, for use with Flowline DL34, LU23, LU28, LU29, LU74, LU78, LU81, LU83,
and LU84 series ultrasonic level sensors
1
0.1
$13.00
When installing the 1” NPT level sensors care should be used to mechanically isolate the sensor housing from the tank. This can easily
be done by using any of the Flowline mounting accessories which are designed to provide the isolation needed.
Dimensions
inches [mm]
LM50-1001
LM50-1001-1
Book 2 (14.3)
eLE-22
Level Sensors
1-800-633-0405
Prices as of April 27, 2016. Check Web site for most current prices.
Ultrasonic Liquid Level Sensor
Accessories
Dimensions
Drives
Soft Starters
Motors
inches [mm]
LM52-1400
Company
Information
Power
Transmission
LM52-2400
Motion: Servos
and Steppers
Motor Controls
Sensors:
Proximity
Sensors:
Photoelectric
Sensors:
Encoders
Sensors:
Limit Switches
Sensors:
Current
LM52-1890
Sensors:
Pressure
LM52-2890
Sensors:
Temperature
Sensors:
Level
Sensors:
Flow
Pushbuttons
and Lights
Stacklights
Signal
Devices
Process
Relays and
Timers
LM52-1850
LM52-2850
Pneumatics:
Air Prep
Pneumatics:
Directional Control
Valves
Pneumatics:
Cylinders
Pneumatics:
Tubing
Pneumatics:
Air Fittings
Appendix
Book 2
Terms and
Conditions
Book 2 (14.3)
www.automationdirect.com/ultrasonic-level-sensors
Level Sensors
eLE-23
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project