Agilent Technologies | 82357B | Agilent I/O Hardware for PC-to-Instrument Connection

Agilent I/O Hardware for PC-to-Instrument Connection
Agilent I/O Hardware for
PC-to-Instrument Connection
Data Sheet
• Choose the best way to connect your
PC to GPIB and RS-232 instruments
Easily connect your PC to
GPIB and RS-232 instruments
• Take advantage of PC-standard
interfaces (USB, LAN, PCI)
Now you can connect your PC and
test instruments more easily than
ever. The Agilent I/O hardware
product family is designed to offer
you a choice of interfaces and to
simplify the connection.
• Protect your investment with
industry-standard I/O software
Table of contents
82357B USB/GPIB Interface
82350B High-Performance PCI GPIB
Interface
82351 PCIe GPIB Interface
E5810A LAN/GPIB Gateway
E5805A USB/4-Port RS232 Interface
E5813A Networked 5-Port USB Hub
Cables and Adapters
Choosing a remote connection
Ordering information
Related Agilent literature
2
3
4
5
6
7
8
8
9
9
Agilent is a leader in offering
Ethernet/local area network (LAN)
and universal serial bus (USB)
interfaces in its instruments. The
I/O products featured in this data
sheet will help you connect your
current instruments that have GPIB
or RS-232 interfaces to your PC
with ease.
Agilent I/O hardware family benefits:
• Easy connection to GPIB and RS232 instruments — Agilent I/O
hardware products offer simple
“plug and go” setup and configuration
• Use PC-standard interfaces —
Connect via your computer PCI
slot or use the built-in USB or
LAN ports on your PC to connect
to your instruments.
• Choice of interfaces (GPIB, RS232, USB, LAN, PCI) — Agilent
offers you a selection of products
to meet your I/O needs. We work
where you do!
• Software compatibility with any
standard T&M software application — The included industry-standard VISA I/O libraries make it
easy for you to use your existing
software programs and let you
mix and match test instruments
and software from different vendors in a single system.
Agilent connectivity software
Agilent connectivity software helps you establish a connection in less than 15 minutes.
Agilent IO Libraries Suite eliminates the
hours of effort it takes to connect and
configure PC-controlled test systems.
This connectivity software ships with each
Agilent I/O product and over 150 Agilent
test and measurement instruments.
Connecting your instruments to a PC is as
easy as connecting a PC to a printer — even
if you use multiple instrument vendors.
Now enhanced version 14.2 with expanded
compatibility with other vendors IO software.
You can now use any programming API
with any standard T&M software development environment. Simply install Agilent’s
IO Libraries Suite on your PC then cable the
interfaces and instruments to your PC. The
IO Libraries Connection Expert utility will find
the interfaces and instruments connected to
your computer and configure them properly.
Agilent IO Libraries Suite version 14.2
summary of requirements
• Microsoft® Windows® 98(SE)/ME
(note: only supported with version 14.0)/2000
SP4/XP SP1/Vista (note: only supported with
version 15.0 or greater) and Microsoft Internet
Explorer 5.01 or greater
• 450 MHz Intel Pentium® processor
and 800x600 display with 256 colors
• 128 megabytes RAM and 225 MB total
hard disk space
• Supported APIs include Agilent or NI
VISA, SICL, VISA-COM and NI-488.2
If you already own an Agilent I/O product
or instrument, you can download the latest
version of Agilent IO Libraries Suite for free.
See the following URL for more information.
Go to www.agilent.com/find/iosuite
Agilent 82357B USB/GPIB
Interface
Features
• Fast and easy connection to GPIB
instruments
Boosting performance with
simplest connectivity
• Uses standard USB and IEEE-488
interfaces
• Maximum GPIB transfer rate of
more than 1.15 MB/s
• Use industry standard software
82357B Technical Specifications
General Requirements
Minimum system requirements
• Windows 2000/XP Professional/Vista
• 450 MHz Pentium II (800 MHz is recommended)
• 128 MB RAM (256 MB or greater is recommended)
• 400 MB free disk space
• USB port (OS and Microsoft .NET Framework may require
more resources)
Supported standards
• Support USB 2.0 high speed and full speed
• Standard USB endpoints supported
• IEEE-488.1 and IEEE-488.2 compatible
• SICL and VISA 2.2
Best for
• Easiest GPIB connectivity
• Notebook computer GPIB
connections
Connect GPIB instruments quickly and
easily to your computer’s USB port
The Agilent 82357B USB/GPIB
interface provides a direct connection from the USB port on your
desktop and laptop computers to
GPIB instruments. Once the software is loaded, your computer
automatically detects the 82357B
when it is connected to the computer USB port.
With the 82357B USB/GPIB interface and its convenient plug-andplay feature, you just plug and go.
It is also hot pluggable, making it
easy to connect and disconnect
without having to shut down the
computer. No external power supplies are necessary.
The 82357B USB/GPIB interface
implements USB 2.0 (480 Mbits/s)
and is backward compatible with
USB 1.1. The 82357B USB/GPIB
interface uses a thin, flexible, highquality USB cable that is USB 2.0
compliant. The USB cable is shielded, and the connector is specified
to 1,500 insertions, ensuring a
durable connection and reliable
data transfer.
Unsupported GPIB modes of operation • Pass Control
• Non-System Controller mode
General Characteristics
Power
USB bus-powered device, +5 V, 500 mA (max), 200 mA (typ)
GPIB transfer rate
1.15 MB/s or better
Connectors
• Standard 24-pin IEEE-488
• Standard USB A
USB hubs
Self-powered hubs
Parallel polling
A single parallel poll can easily check up to eight individual
devices at once, corresponding to the number of data lines
on the GPIB.
Cable
2.5 meters, shielded, connector rated for 1500 insertions
LED Indicators
READY, ACCESS, FAIL
Maximum connections
Maximum 4 converters can be connected to the PC
Instrument connections
14 instruments—daisy chain via GPIB
Configuration
Plug-and-play
Warranty
1 year
EMC and Safety *
• IEC 61010-1:2001/EN 61010-1:2001
• Canada: CSA C22.2 No. 61010-1:2004
• USA: UL61010-1: 2004
Dimensions
Length, width, and height
105 mm (L) x 64 mm (W) x 30 mm (H) (includes connectors)
Weight
215 grams
Environmental Specifications
Operating environment
0 °C to 55 °C
Storage environment
–40 °C to +70 °C
Operating humidity
Up to 90 % at 40 °C non-condensing
Storage humidity
Up to 90 % at 65 °C non-condensing
* Additional details and information in the Declaration of Conformity
2
Agilent 82350B
High-Performance PCI GPIB
Interface for Windows
Features
• PCI IEEE-488 interface for PCs
• Transfer rates up to 900 KB/s
• Dual processor support on
Windows 2000/XP/Vista
This traditional GPIB connection
still offers the highest throughput
Best for
• Maximum GPIB throughput for
all configurations
High performance for manufacturing
test applications
The 82350B is Agilent’s highestperformance GPIB interface. With
a direct PCI computer connection,
transaction overhead is minimized
for the best overall performance.
The 82350B card de-couples GPIB
transfers from PCI bus transfers.
Buffering provides I/O and system
performance that is superior to
direct memory access (DMA). The
hardware is software configurable
and compatible with the Plug-andPlay standard for easy hardware
installation. The GPIB interface card
plugs into a 5 volt PCI slot in the
backplane of your PC.
For programming capability you
have access with the latest version
of IO Libraries suite, version 14.2,
to program in all standard development environments. Agilent’s IO
Libraries Suite 14.2 is easy to use
and works with virtually any vendor’s instrument or T&M programming software application and
includes automatic configuration for
Agilent or NI VISA, NI-488.2, VISA
COM or T&M Toolkit Direct IO.
Even if you use NI IO software
Agilent will configure automatically
so as a user you do not have to be
concerned with the behind-thescenes details.
82350B technical specifications
General requirements
Minimum system requirements
Windows 98(SE)/Me
(note 98 supported with version 14.0 only)/2000/XP/Vista
Software required
Agilent IO Libraries Suite (included);
see requirements on page 1
PCI bus slot
5-V PCI slot, 32 bits
Supported standards
PCI rev 2.2
IEEE 488.1 and IEEE 488.2 compatible
General characteristics
Power
Backplane +5 V PCI
Connectors
Standard 24-pin GPIB (IEEE-488)
+5V PCI
Maximum data rate
More than 900 KB/s
Maximum instrument connection
14 instruments—daisy chain via GPIB
Buffering
Built-in
Configuration
Plug-and-Play
EMC and safety *
IEC 61326-1
IEC 61010-1
Warranty
1 year
Group 1, Class A
Dimensions
Length, width, and height
122 mm (L) x 122 mm (W) x 22 mm (H) (a full-height PCI card)
Weight
0.091 kg
Environmental specifications
Operating environment
0°C to 55°C
Operating humidity
Up to 90% at 40°C non-condensing
Storage environment
-40°C to +70°C
Storage humidity
Up to 90% at 65°C non-condensing
* Additional detail and information in the Declaration of Conformity
3
Agilent 82351A
PCIe GPIB Interface Card
Features
• Compact half-height size
(68.9 mm)
New standard for high
speed internal devices
• High transfer rate of 1.4 MB/s
• High flexibility via up-plugging
(to x4 or x8 PCIe slots)
• 3.3 V signal level for lower
power consumption
• Compatibility with industry
standard PCIe rev 1.0a and
IEEE-488
• Interface to 14 GPIB instruments
(max)
82351A technical specifications
General requirements
Minimum system requirements
Windows 2000/XP/Vista
• Bandwidth-intensive PC applications
Software required
Agilent IO Libraries Suite 14.2 and above;
see requirements on page 1
PCI bus slot
3.3 V PCIe slot, 32 bits
• Adding GPIB connection for
PCIe-based PCs or workstations
Supported standards
PCIe rev. 1.0a
IEEE 488.1 and IEEE 488.2 compatible
Best for
High transfer rate for demanding test
applications
Agilent 82351A PCIe-GPIB interface
card is designed for integration into
next generation PCs or workstations. It offers fast data transmission for various demanding test
applications that require data to be
transferred to memory fast enough
without any lost or overwritten.
PCIe (PCI Express) is an evolutionary version of PCI that offers a
higher transfer rate across a low
number of wires. It is also backward-compatible with PCI software,
so you don’t need to perform any
code re-configuration. PCIe’s powerful bus architecture allows bidirectional data transmission, and
the implementation of a new class
of test applications.
General characteristics
Power
Backplane +3.3 V PCIe
Connectors
Standard 24-pin (IEEE-488)
+1.5 V PCIe
Maximum data rate
1.4 MB/s or better
Maximum instrument connection
14 instruments—daisy chain via GPIB
Buffering
Built-in
Configuration
Plug-and-Play
EMC and safety *
IEC 61010-1:2001 / EN61010-1:2001
Canada: CSA C22.2 No. 61010-1:2004
IEC 61326:2002 / EN61326:1997+A1:1998+A2:2001+A3:2003
Pollution Degree 2
This product is rated for indoor use only
Warranty
1 year
Dimensions
Width, depth and height
158.0 mm (W) x 120.8 mm (D) x 21.6 mm (H)
Weight
0.082 kg
Environmental specifications
Operating environment
–5 °C to 60 °C
Operating humidity
Up to 90% at 40 °C non-condensing
Storage environment
–40 °C to 70 °C
Storage humidity
Up to 90% at 65 °C non-condensing
* Additional detail and information in the Declaration of Conformity
4
Agilent E5810A LAN/GPIB
Gateway
Take advantage of LAN
technology for your GPIB
instruments and test
systems
Features
• Remote access and control of
GPIB instruments via the LAN
• Easy setup and use via digital
display and Web browser
Best for
• Connection to remote GPIB and
RS-232 instrumentation
• Shared test systems
Remote access and collaboration
with GPIB instruments via your LAN
The E5810A can use DHCP, if available, to automatically configure necessary network parameters, including its IP address. The gateway can
be controlled from multiple locations
and by multiple users via your LAN,
so it is easy to share control of
instruments from locations worldwide.
For easy remote access enter the IP
address from the digital display as
the URL in your Web browser and
gain access to connected GPIB and
RS-232 instruments. Then use your
browser to send instrument commands interactively and quickly see
your measurement results. Use the
digital display and LEDs to check
the IP address and troubleshoot
locally.
For programming capability you
have access with the latest version
of IO Libraries Suite, version 14.2,
to program in all standard development environments.
System use
For system environments, the
E5810A gateway can be rack
mounted. The rack mount kit
(Option 100) allows two devices to
be placed side-by-side in one rack
width. With its built-in power supply, there are no additional power
modules to mount.
E5810A technical specifications
baud rates up to 230 Kb/s per serial port. The E5805A provides four
DB9 serial connectors and ships
Minimum system requirements
Available 10BASE-T/100BASE-TX
portcable.
with a 1.8-meterLAN
USB
Features
(client computers)
• Easy connection from standard
Operating system
Windows 98(SE)/Me
USB port on your PC to up(note
to 98 supported
Agilent
with E5813A
version 14.0Networked
only)/2000/XP/Vista
four RS-232 instruments or Internet Explorer 4.0 or higher
Supported Web browsers
5-Port USB Hub
devices
Netscape Navigator 4.7 and higher
Agilent E5805A USB/
4-Portrequirements
RS232 Interface
General
Software
Web browserFeatures
or for programmatic control—
•
Fullyrequired
compatible with Windows
• Interface
a variety of GPIB, RSAgilent
Suite (included);
COM driver and industry-stan- IO Libraries
see requirements
on page
232,
and1 USB devices to complete
dard VISA I/O software.
Supported standards
IEEE 488.1 and IEEE
your488.2
testcompatible
system
Best for
10BASE-T/100BASE-TX networks
• Extend USB devices beyond five
• Easy connection to RS-232 VXI-11 protocol
meters
EIA-232
devices
General characteristics
• USB ports appear to be locally
• Notebook computer RS-232
Power supply
100-240 V ± 10%
attached and are locked to one
connections
Power consumption
(7 watts) 25 VAcomputer
peak
Power
line frequency
Add four
serial ports in minutes 47 to 63 Hz
Best for
The Agilent E5805A USB/4-port
Connectors
Std 24-pin GPIB
(IEEE-488),access
RS-232 (9-pin),
LAN
RJ-45
• Remote
to USB
ports—
RS232
Maximuminterface
data rates provides a direct
More than 900 KB/s—GPIB
devices orport
instruments
connection from the USB port115
onKb/s—RS-232 port
your notebook
to up
Connect
remote
USB,
GPIB
or115200 b/s
RS-232
baud rate or desktop PC 300,
1200, 2400,
4800, 9600,
19200,
38400,
57600,
to
four
RS-232
instruments
or
RS-232
instruments
or
devices
via
RS-232 Flow control
None, RTS/CTS, XON/XOFF, DTR/DSR
devices. There are no switches to
a
standard
LAN
RS-232 Parity
None, Odd, Even, Space, Mark
set, no PC cards to install, and no
The Agilent E5813A networked 5RS-232
bits
5,
6, 7, 8
external power supplies are
port USB hub uses LAN technology
RS-232
Stop bits
1, 2
required.
Simply install the driver
to overcome the 5-meter distance
RS-232
SRQ interrupts
on RI, DSR, DCD, CTS
and plug
in the E5805A USB 4-port
RS232
interface
to add four RS-232
Max
instrument
connections
14 instruments—daisy chain via GPIB
1 RS-232 device
ports to your computer.
Up to 16 simultaneous I/O connections
Since the E5805A is a standard
Indicators
LEDs for Power, Activity, Fault
Plug-and-Play
EMC and safety * device, your computIEC 61326-1
Group 1, Class A
er automatically detects and configIEC 61010-1
ures
it when it is connected to
Warranty
1 year
your computer USB port. You can
Network protocols
See the E5810A User’s Manual for supported network
interface up to four devices, with
protocols and functions
Dimensions
Length, width, and height
211 mm wide x 230 mm deep x 41 mm high
(1U height, 1/2 rack)
Weight
1.6 kg
Environmental specifications
For additional information and
graphic see page 8.
Operating environment
0°C to 55°C
Operating humidity
Up to 90% at 40°C non-condensing
Storage environment
-40°C to +70°C
Storage humidity
Up to 90% at 65°C non-condensing
* Additional detail and information in the Declaration of Conformity
5
Agilent E5805A USB/4-Port
RS232 Interface
Turn your USB port into
4 additional RS-232 ports
Features
• Easy connection from standard
USB port on your PC to up to
four RS-232 instruments or
devices
• Fully compatible with Windows
COM driver and industry-standard VISA I/O software
E5805A technical specifications
Best for
Minimum system requirements
• Easy connection to RS-232
devices
• Notebook computer RS-232 connection
Add four serial ports in minutes
The Agilent E5805A USB/4-port
RS232 interface provides a direct
connection from the USB port on
our notebook or desktop PC to up
to four RS-232 instruments or
devices. There are no switches to
set, no PC cards to install, and no
external power supplies are
required. Simply install the driver
and plug in the E5805A USB 4port RS232 interface to add four
RS-232 ports to your computer.
Since the E5805A is a standard
Plug-and-Play device, your computer automatically detects and configures it when it is connected to
your computer USB port. You can
interface up to four devices, with
baud rates up to 230 Kb/s per
serial port. The E5805A provides
four DB9 serial connectors and
ships with a 1.8-meter USB cable.
General requirements
Windows 98(SE)/Me
(note 98 supported with version 14.0 only)/2000/XP
A USB port
Software required
E5805A driver (included)
Software recommended
Agilent IO Libraries Suite (included);
see system requirements on page 1
Supported standards
USB 1.1 (fully compatible with USB 2.0)
EIA-232
General characteristics
Power
USB bus-powered device, +5 V, 500 mA (max), 200 mA (typ)
Support for USB hubs
Self-powered hubs
Connectors
Standard USB A, RS-232 (9-pin) on each port
Cable
1.8 meter USB, USB A (host side) to USB B (device side)
Maximum data rates
230 Kb/s per port
RS-232 baud rates
300, 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200,
230400 b/s
RS-232 flow control
None, RTS/CTS, XON/XOFF, DTR/DSR
RS-232 parity
None, Odd, Even, Space, Mark
RS-232 bits
5, 6, 7, 8
RS-232 Stop bits
1, 2
RS-232 SRQ interrupts
on RI, DSR, DCD, CTS (using IO libraries)
Maximum instrument connections
4 RS-232 instruments/devices
Configuration
Plug-and-Play
Indicators
Tri-state LED displays device status and COM port activity
EMC and safety *
CISPR 22
CISPR 24
IEC 60950
Warranty
1 year
Class B
Dimensions
Length, width, and height
111 mm (L) x 183 mm (W) x 26 mm (H)
Weight
0.311 kg
Environmental specifications
Operating environment
0°C to 55°C
Operating Humidity
Up to 90% at 40°C non-condensing
Storage environment
-40°C to +70°C
Storage humidity
Up to 90% at 65°C non-condensing
* Additional detail and information in the Declaration of Conformity
6
Agilent E5813A Networked 5Port USB Hub
Utilize LAN to access the
remote USB, GPIB or RS232 instruments or devices
Features
• Interface a variety of GPIB, RS232, and USB devices to complete
your test system
• Extend USB devices beyond five
meters
• USB ports appear to be locally
attached and are locked to one
computer
E5813A technical specifications
General requirements
Minimum system requirements
Windows 2000/XP
Available USB 1.1 or 2.0 port
Software required
E5813A driver (included)
• Remote access to USB ports—
devices or instruments
Software recommended
Agilent IO Libraries Suite (included);
see system requirements on page 1
Supported standards
10BASE-T/100BASE-TX networks
USB 1.1 (fully compatible with USB 2.0)
Connect remote USB, GPIB or
RS-232 instruments or devices via
a standard LAN
General characteristics
Best for
The Agilent E5813A networked 5port USB hub uses LAN technology
to overcome the 5-meter distance
limitation for USB cabling, so you
can place USB devices anywhere on
a LAN network. With access to
remote devices, you can collect data,
perform measurements, or monitor
the progress of your tests. Using the
included IO Libraries Suite, you can
connect an Agilent 82357B USB/GPIB
interface to one of the USB ports for
access to GPIB devices. You also can
connect an E5805A USB/4-port RS232 interface for access to RS-232
devices (see figure on page 8).
To prevent access conflicts, only one
computer at a time can access the
E5813A. The included software lets
you lock the E5813A to your computer. Once you unlock the connection, another user can then connect
from a different computer.
For information on choosing between
E5810A and E5813A see page 8.
Power supply
External switching AC adapter
Input power consumption
120/230 volts AC, 0.7amps
Power line frequency
50 to 60 Hz
Output
5 volts DC, 3 amps max
USB device power available
500 mA per device
Connectors
LAN RJ-45
Standard USB A on each of 5 ports
Maximum data rates
12 Mbps from each port
Maximum instrument connections
5 USB instruments or devices
Configuration
Remote LAN configuration utility
Indicators
LEDs for system and device status
EMC and safety *
CISPR 22
Class B
CISPR 24
IEC 60950
ITE equipment intended only for use with ISM equipment
Warranty
1 year
Network and device recommendations
IP addresses
One IP address per unit
E5813A Device Sharing
Locked to one computer at a time. One computer must
release the E5813A before another computer can use it.
Network utilization
Maximum network utilization below 50%
Compatibility
Compatible with bulk or interrupt-type USB devices;
isochronous devices are not supported.
Dimensions
Length, width, and height
Device: 112 mm (L) x 182 mm (W) x 26 mm (H)
Power adapter: 110 mm (L) x 60 mm (W) x 35 mm (H)
Weight
Device: 0.284 kg
Power adapter: 0.25 kg
Environmental specifications
Operating environment
0°C to 55°C
Operating Humidity
Up to 90% at 40°C non-condensing
Storage environment
-40°C to +70°C
Storage humidity
Up to 90% at 65 °C non-condensing
* Additional detail and information in the Declaration of Conformity
7
Cables
Choosing a remote connection
Agilent also offers a variety of
cables that provide easy and reliable connections. Agilent cables are
engineered for exceptional reliability and durability, even under the
harshest conditions.
Guidelines for selecting between the
E5810A and E5813A for a remote
connection:
• Use the E5810A LAN/GPIB gateway
when you are connecting only to GPIB
instruments or a mix of GPIB instruments and one RS-232 instrument.
• Use the E5810A when you need to
share your instruments with more
than one user at a time.
Cable
Length
10833D GPIB cable
0.5 meter
10833A GPIB cable
1 meter
10833B GPIB cable
2 meter
10833C GPIB cable
4 meter
10833F GPIB cable
6 meter
10833G GPIB cable
8 meter
Adapters
10834A GPIB-to-GPIB adapter
The 10834A GPIB-to-GPIB adapter
can help when limited rear-panel
space and other design considerations make cabling difficult. The
10834A adapter extends the first
cable 2.3 cm away from the rear
panel to provide clearance for other
connectors, switches, and cables.
8
• Use the E5813A networked 5-port
USB hub when you have a mix of
devices (for example, when you need
a remote USB printer and multiple
RS-232 devices, or have a mix of GPIB,
USB, and RS-232 devices).
You will obtain the best performance when
you do the fewest format conversions. For
example using the E5810A (LAN to GPIB)
will generally be faster than 82357B and
an E5813A (LAN to USB to GPIB).
www.agilent.com
Ordering information
Product
number
Product description
82357B
USB/GPIB interface, includes
Agilent IO Libraries Suite and
VISA/SICL programming manuals
on CD-ROM.
E5810A
LAN/GPIB gateway, includes
Agilent IO Libraries Suite and
VISA/SICL programming manuals
on CD-ROM.
Rack mount kit for 1 or 2 E5810A(s)
Option 100
82350B
High performance PCI GPIB
interface, includes Agilent IO
Libraries Suite and VISA/SICL
programming manuals on CD-ROM
82351A
High performance PCIe GPIB
Interface Card, includes Agilent IO
Libraries Suite and VISA/SICL
programming manuals on CD-ROM
Related Agilent literature
(for other application-related topics and
publications, visit
www.agilent.com/find/appcentral)
• Agilent E2094N IO Libraries Suite, Data sheet
pub no. 5989-1439EN
• Modern Connectivity–Using USB and LAN I/O
Converters, Application note 1475-1
pub no. 5989-0123EN
• Simplified PC Connections for GPIB Instruments,
Application note 1409-1, pub no. 5988-5897EN
• Using LAN in Test Systems: The Basics,
Application note 1465-9, pub no. 5989-1412EN
• Using LAN in Test Systems: Network
Configuration, Application note 1465-10,
pub no. 5989-1413EN
• Using USB in the Test and Measurement
Environment, Application note 1465-12,
pub no. 5989-1417EN
• Computer I/O Considerations,
Application note 1465-2, pub no. 5988-9818EN
Learn more at
http://www.agilent.com/find/io-ds
Join the Agilent Developer Network to get updated
I/O software, instrument drivers, code examples,
white papers, and more! Registration is easy and
free at www.agilent.com/find/adn.
Additional manual set (Option 0B1);
Japanese User’s Guide (Option
ABJ)
E5805A
E5813A
USB/4-port RS232 interface
includes USB cable, Agilent IO
Libraries Suite and VISA/SICL
programming manuals on CD-ROM
Networked 5-port USB hub—
includes power adapter, Agilent IO
Libraries Suite and VISA/SICL
programming manuals on CD-ROM
10833D
0.5-meter GPIB cable
10833A
1-meter GPIB cable
10833B
2-meter GPIB cable
10833C
4-meter GPIB cable
10833F
6-meter GPIB cable
10833G
8 meter GPIB cable
10834A
GPIB-to-GPIB adapter
More Information
[1] PCIe-GPIB Interface Card Product
Information:
www.agilent.com/find/82351A
[2] Agilent I/O Product Family:
www.agilent.com/find/io
[3] Agilent I/O Product Promotion &
Special Deal:
www.agilent.com/find/iopromo
Agilent Technologies’ Test and Measurement
Support, Services, and Assistance
Agilent Technologies aims to maximize the value you
receive, while minimizing your risk and problems. We
strive to ensure that you get the test and measurement
capabilities you paid for and obtain the support you
need. Our extensive support resources and services
can help you choose the right Agilent products for your
applications and apply them successfully. Every instrument and system we sell has a global warranty. Support
is available for at least five years beyond the production
life of the product. Two concepts underlie Agilent’s overall
support policy: “Our Promise” and “Your Advantage.”
Our Promise
Our Promise means your Agilent test and measurement
equipment will meet its advertised performance and
functionality. When you are choosing new equipment,
we will help you with product information, including
realistic performance specifications and practical recommendations from experienced test engineers. When you
receive your new Agilent equipment, we can help verify
that it works properly, and help with initial product
operation.
Your Advantage
Your Advantage means that Agilent offers a wide
range of additional expert test and measurement
services, which you can purchase according to your
unique technical and business needs. Solve
problems efficiently and gain a competitive edge
by contracting with us for calibration, extra-cost
upgrades, out-of-warranty repairs, and onsite education
and training, as well as design, system integration, project
management, and other professional engineering
services. Experienced Agilent engineers and technicians worldwide can help you maximize your productivity,
optimize the return on investment of your Agilent
instruments and systems, and obtain dependable
measurement accuracy for the life of those products.
Agilent Email Updates
www.agilent.com/find/emailupdates
Get the latest information on the products and
applications you select.
Agilent Open
www.agilent.com/find/open
Agilent Open simplifies the process of connecting and
programming test systems to help engineers design,
validate and manufacture electronic products. Agilent
offers open connectivity for a broad range of systemready instruments, open industry software, PC-standard I/O and global support, which are combined to
more easily integrate test system development.
For more assistance with your test & measurement
needs or to find your local Agilent office go to
www.agilent.com/find/contactus
Microsoft, Windows and Visual Studio are U.S.
registered trademarks of Microsoft Corporation.
Pentium is a U.S. registered trademark of Intel
Corporation.
Product specifications and descriptions in this
document subject to change without notice.
© Agilent Technologies, Inc. 2004 – 2007
Printed in USA, May 21, 2007
5989-1889EN
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising