mini CORI-FLOW Coriolis Mass Flow Controller model ML120V00

mini CORI-FLOW Coriolis Mass Flow Controller model ML120V00
Datasheet ML120V00
Low Flow Coriolis Mass Flow Meter
> Introduction
Bronkhorst® model ML120V00 mini CORI-FLOW™ Mass Flow
Meters (MFMs) for liquids and gases are precise and compact
instruments, based on the Coriolis measuring principle,
designed to cover the needs of the low flow market. The MFMs
offer “multi-range” functionality: factory calibrated ranges can
be rescaled by the user, maintaining the original accuracy specs.
The MFM contains a microprocessor based pc-board with signal and
fieldbus conversion. The mass flow is provided as analog signal or
digitally via RS232 or optional fieldbus. The flow range and wetted
materials are determined depending of the type of fluid and the
process conditions of the application.
> Technical specifications
Flow ranges
mini CORI-FLOW Coriolis Mass Flow Meter model ML120V00
Mechanical parts
Minimum full scale
: 5 g/h
Material (wetted parts)
: Stainless steel 316L or comparable
Nominal flow
: 100 g/h
Sensor
: Single tube, DN 0.25; frequency 170 Hz ±20 Hz
Maximum full scale
: 200 g/h
Process connections (welded)
: Compression type or face seal couplings
Minimum flow
: 50 mg/h
Seals
: Kalrez®
Rangeability MFM
: 1:4000
Performance
Mass flow accuracy
: Liquid: ± 0,2% of rate; Gas: ± 0,5% of rate
Repeatability
: ± 0,05% of rate ± ½(ZS* x 100/flow)%
based on digital output
Warm-up time
Ingress protection (housing)
: IP40
Leak integrity
: Outboard <2x10-9 mbar l/s He
Pressure rating MFM
: 200 bara
Electrical properties
Power supply
: +15…24 Vdc ±10%
Power consumption
: max. 2,5 W
Analog output
: 0…5 (10) Vdc, min. load impedance > 2 kΩ;
Analog setpoint
: 0…5 (10) Vdc, min. load impedance > 100 kΩ;
Digital communication
: Standard RS232; Options: PROFIBUS DP, DeviceNetTM,
: > ½ hour after power up
for optimum performance
Zero stability (ZS)*
: < ±10 mg/h
Density accuracy
: < ±5 kg/m3
Temperature accuracy
: ±0,5 °C
Temperature effect**
: on zero: < 3 mg/h/°C;
on span: < 0,005% Rd/°C;
Max. ripple recommended: 50 mV tt
0 (4)…20 mA (sourcing), max. load impedance < 375 Ω
0 (4)…20 mA, load impedance ~250 Ω
self heating (at zero flow): < 10°C
Mounting***
: Any position, attitude sensitivity negligible
Device temperature
: 0…70°C;
Response time, meter
: ≤ 200 msec
* Guaranteed at constant temperature and for unchanging process and environment conditions.
** Depends on flow rate, heat capacity fluid, T amb., T fluid and cooling capacity.
*** To be rigidly bolted to a stiff and heavy mass or construction for guaranteed zero stability.
External shocks or vibrations should be avoided.
Although all specifications in this datasheet are believed to be accurate, the right is reserved to
make changes without notice or obligation.
Modbus RTU/ASCII, FLOW-BUS, EtherCAT®, PROFINET
Electrical connections
Analog/RS232
: 9-pin D-connector (male)
PROFIBUS DP
: bus: 9-pin D-connector (female);
DeviceNet™
: 5-pin M12 connector (male)
power: 9-pin male D-connector (male)
Modbus RTU/ASCII/FLOW-BUS
: RJ45 modular jack
EtherCAT®/PROFINET
: 2 x RJ45 modular jack (in/out)
> Model number identification
ML120
V00
Mass Flow Meter
ML120 Nominal flow 100 g/h
A
A
NN
A
A
Material
S Stainless steel
Communication (I/O)
A RS232 + Analog
C RS232 + DeviceNet
M RS232 + Modbus
P RS232 + PROFIBUS DP
R RS232 + FLOW-BUS
T RS232 + EtherCAT
V RS232 + PROFINET
Internal seals
K Kalrez (FFKM)
Z Other (on request)
Connections (in/out)
AA 3 mm OD compression type
BB 1/8”Face seal male
CC 1/16” OD Compression type (default)
11 1/8” OD Compression type
99 other
Control Valve
V00 No valve (flow meter only)
Analog output
A 0…5 Vdc
B 0…10 Vdc
F 0…20 mA sourcing
G 4…20 mA sourcing
> Coriolis principle of operation
A
Instruments of the mini CORI-FLOW™ series are based on the
Coriolis effect: a fluid flows through a uniquely shaped, single loop
sensor tube, forming part of an oscillating system. Coriolis forces
cause a variable phase shift, which is detected by sensors and fed
into the integrally mounted pc-board. The resulting output signal
is strictly proportional to the real mass flow rate. Coriolis mass flow
measurement is fast, accurate and inherently bi-directional. The
mini CORI-FLOW™ features density and temperature of the fluid
as secondary outputs.
Supply voltage
D + 15…24 Vdc
> State of the art digital design
mini CORI-FLOW™ series are equipped with a digital pc-board,
offering high accuracy, excellent temperature stability and fast
response. The basic digital pc-board contains all of the general
functions needed for measurement and control. In addition to the
standard RS232 output the instruments also offer analog I/O.
Furthermore, an integrated interface board provides DeviceNet™,
PROFIBUS DP, Modbus RTU/ASCII, EtherCAT™, PROFINET or
FLOW-BUS protocols.
Schematic of a Coriolis flow sensor
Functional scheme of the digital PC-board
> Hook-up diagram for analog or RS232 communication
Optional fieldbus
Standard RS232
9 pin D-Sub
Analog/RS232
Doc. 9.16.132
Doc. 9.16.133
Doc. 9.16.134
Doc. 9.16.135
Doc. 9.16.136
Doc. 9.16.137
Doc. 9.16.138
> Dimensions (mm)
Length (L)
incl. adapters
OD Compression type
Size L
1/16 inch
other
120
on request
> Options and accessories
- Free software support for operation, monitoring, optimizing or to interface
between digital instruments and windows software.
- BRIGHT compact local Readout/Control module
- E-8000 Power Supply/Readout Units
- Interconnecting cables for power and analog/digital communication
- PiPS Plug-in Power Supply
- Heavy mass body and vibration-dampeners
> Alternatives
- Model ML120V21 mini CORI-FLOW™ Mass Flow Controller (flow rates from 0,05 up to 200 g/h)
- Model M12 mini CORI-FLOW™ Mass Flow Controller (flow rates from 0,1 up to 200 g/h) ; class IP65
Bronkhorst High-Tech B.V. Nijverheidsstraat 1a, NL-7261 AK Ruurlo The Netherlands
T +31 (0)573 45 88 00 F +31 (0)573 45 88 08 I www.bronkhorst.com E [email protected]
E.DS.ML120V200.03156B
- Model M13 mini CORI-FLOW™ Mass Flow Controller (flow rates from 1 up to 2000 g/h) ; class IP65
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement