The IS2000 MK1 is an Intrinsically Safe PIR Detector designed for use in hazardous areas such as the petrochemical industry, gas plants, explosive manufacturing, pharmaceutical industry, sewage treatment plants, and other locations with potentially explosive atmospheres. When a person moves into the IS2000 MK1’s field of view, the detector will detect their infra-red energy (body heat) and output a signal. This signal can be used to trigger an alarm system, control factory personnel access, switch on hazardous area lighting, or activate battery-powered emergency lighting only when needed.

advertisement

Assistant Bot

Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.

Voltek Automation IS2000 MK1 Intrinsically Safe PIR Detector Installation Instructions | Manualzz
IS2000 - Intrinsically Safe PIR Detector
Installation Instructions
INTRODUCTION
-
The IS2000 is an ATEX and IECEx approved and
certified product designed specifically for use in
hazardous areas such as the petrochemical
industry, gas plants, explosive manufacturing /
storage,
pharmaceutical
industry,
sewage
treatment plants, ……. indeed anywhere there is a
potentially explosive atmosphere.
The detector is a movement sensor that works by
looking for moving body heat (infra-red energy).
The detector will connect to your alarm system or
other control equipment to warn of human
presence.
The IS2000 must be used with an approved barrier
which will limit the voltage and current to approved
levels for the IS2000.
A suitable zener barrier can be found in the ZE
Interface Unit, which also incorporates signal
processing electronics to provide a perfect
interface between the IS2000 and your control
equipment. The ZE Interface would be installed in
a non-hazardous area and connected with a four
core cable to the IS2000 within the hazardous
area.
Please Note: the operating temperature range for
this device is –20oC to +40oC, which may differ
from that specified in the IS2000 brochure
PRODUCT FEATURES
•
•
•
•
•
•
•
•
•
•
•
-
18m nominal detection range
90o viewing angle
Simple 4 wire connection
Maintenance free
Very high immunity against RFI, EMI and
reflected sunlight
High gain fresnel optics provide true volumetric
coverage of the detection area
ATEX and IECEx approved and certified
BS EN 60079 approved
Ex ia IIC T5 Ga approved
Approved for European zone IIA, IIB, and IIC.
IP 67 dust & water tight enclosure
TYPICAL APPLICATIONS
•
•
•
•
-
Connection to your alarm system to warn of an
intruder in a hazardous area
Warns your control room that factory
personnel are in a prohibited area
Connects to your hazardous area lighting
controller to switch them on only when people
are in the area, hence this will reduce your
electricity consumption
Increases the life of your battery powered
emergency lighting by switching them on only
when a presence is detected.
© Voltek Automation Ltd. 1995/2011 IS2000IN.DOC : Rev 4 : QI
1
PRODUCT APPROVALS
-
The approvals on the IS2000 are your guarantee
that a recognised certifying authority has approved
the design to an international standard – thereby
providing you with additional assurance that what
you are buying is a quality product which will serve
the intended purpose
The IS2000 has been ATEX and IECEx approved
and certified by Baseefa Ltd. as meeting the
requirements of the following standards:
IEC/EN 60079 - 0 (Explosive atmospheres –
Part 0 : Equipment - General requirements);
IEC/EN 60079 - II (Explosive atmospheres –
Part II : Equipment protection by intrinsic
safety “i”);
Hazardous area marking : Ex ia IIC T5 Ga
Voltek are specialists in PIR detectors and our
products are designed and manufactured under
the BS EN ISO 9001 quality assurance approval.
Copies of the approval certificates are available on
request.
18m
WHO CAN INSTALL THE IS2000 ?
-
The installation of this equipment must be
performed by engineers with the necessary
experience to work in hazardous areas.
We recommend that you are familiar with BS 5345
part 1 (Selection, installation and maintenance of
electrical apparatus for use in potentially explosive
atmospheres – General recommendations) & BS
5345 part 4 (installation and maintenance
requirements for intrinsically safe electrical
apparatus and systems)
HOW DOES A PIR DETECTOR WORK ? A PIR (Passive Infra Red) sensor will detect a
person’s infra red energy (body heat) when it
moves into it’s field of view. The sensor works by
splitting the area up into detection zones, as shown
in the coverage diagrams below. Whenever a
person is seen moving from one zone to the next,
the sensor will output a signal. The high quality
components, sophisticated filters and noise-free
amplifiers ensure that valid alarms will be
recognised.
Plan View:
Side View:
18m
18m
SITING THE IS2000 PIR DETECTOR
-
For best results locate the sensor so that
movement is across the detection pattern
rather than towards the detector. You will
notice from the detection pattern above, that a
person would cross more beams this way and
the sensor would therefore be more sensitive.
The detector should be mounted at a height of
2.5 to 3 metres for best results.
The unit should be fixed to a rigid, vibration
free vertical surface for reliable operation.
To minimise the possibility of false alarms,
avoid aiming the IS2000 at windows which
may have sunlight shining on them. Also, do
not locate the detector close to heater flues,
heat exchangers, or air conditioning equipment
that may emit warm moving air.
Locating the detector close to branches of
trees or bushes may also cause a false alarm
as these do emit infra-red energy
WHAT ELSE DO I NEED ?
-
The IS2000 package contains an Intrinsically Safe
PIR Detector, a mounting bracket and these
installation instructions. You will also require the
following to complete the installation:
•
•
•
•
© Voltek Automation Ltd. 1995/2011 IS2000IN.DOC : Rev 4 : QI
3 x size 12 by 30mm self tapping screws and
appropriate rawl plugs for affixing the mounting
bracket to the wall
M20 screw cable gland suitable for IP67
weatherproofing, for the IS2000 cable entry
4 core cable suitable for the hazardous area,
including cable clips, cable trunking etc if
required. (The cable must comply with your
building regulations and ‘interconnecting
cables’ section of BS 5345 part 4)
A suitably approved zener barrier or a ZE
Interface Unit
2
INSTALLATION PROCEDURE
Condition of safe use (X Condition). The IS2000
unit must be carefully located during installation to
avoid an ignition hazard due to impact or abrasion.
1.
When the mounting position is chosen, fix the
bracket to the wall utilising the three mounting
holes. Ensure the bracket is in a vertical
position with the PIR support arm at the top.
2.
Hang the IS2000 rear enclosure from the
bracket using the bolt provided.
3.
Run a suitable 4 core cable from the zener
barrier or ZE interface unit to the PIR detector
and feed the cable through the cable entry
hole in the rear enclosure and seal using a
M20 cable gland (not supplied).
4.
WARRANTY
-
IMPORTANT: The IS2000 unit should only be
earthed in the hazardous area on the building
earth by connecting to the earth post in the
rear of the enclosure.
-
The IS2000 has a 1 year parts and labour
warranty. The warranty does not cover any
damage
caused
by
incorrect
installation,
unauthorised additions or modifications to the
product, faults resulting from other manufacturer’s
equipment malfunctioning, natural disasters
(including lightening damage).
There are no user serviceable parts within the
IS2000, however, in the unlikely event that you
encounter a problem with this product, it should be
returned direct to Voltek or the Voltek distributor
from where the product was purchased. Products
covered by the warranty will be repaired free of
charge.
If you have had the equipment installed by a
professional installer, you may wish to take out a
service/maintenance contract with the installer for
extra peace of mind.
TECHNICAL SUPPORT
-
5.
This unit is capable of passing a 500V
isolation test between the intrinsically safe
circuitry and its enclosure.
Should you have any questions about any Voltek
products, please call Voltek on 01282 695 500 and
ask to speak to ‘Technical Support.
6.
Connect the remaining three wires from your
cable to the three way connector using the
following colour code:
+ Red
- Black
S Blue
IS2000 SPECIFICATION
7.
Push the front enclosure into place ensuring
that no cables are trapped and that the gasket
is sitting in place properly
8.
Fasten the six bolts on the front of the
enclosure, using a 10mm socket, to secure the
front into place and provide a dust tight seal.
CONNECTING TO A ZE INTERFACE
-
By connecting to a ZE Interface unit, this already
has a zener barrier installed and pre-wired to a
signal processing board. The output is an alarm
standard, voltage free, normally closed relay, for
each IS2000 connected. Follow the instructions
supplied with the ZE Interface unit for installation
and connections details.
CONNECTING TO A BARRIER
Safety Description
V max (+ connection)
V max (S connection)
I max (+ connection)
I max (S connection)
W max (total)
General
Operating voltage
Current consumption
Output
Optics
Size
Weight
Enclosure Material
-
15V DC
15V DC
150mA
150mA
1.125W
7V to 15V dc
6mA (max)
-ve trigger
Dual element, thermally
stabilised sensor with
U/V protected fresnel,
high density optics.
150 x 100 x 100mm
excluding bracket.
2.5 Kg
Aluminium
-
If you choose not to use the ZE Interface unit, you
will require a barrier for the IS2000 to be connected
to. A suitable zener barrier for use with the IS2000
is available from Voltek. Ordering details:
Part No
: ZB1
Description
: IS2000 Zener Barrier
Voltek Automation Ltd, Unit 39C, Churchill Way,
Lomeshaye Industrial Estate, Nelson, Lancashire.
BB9 6RT
Tel: 01282 695 500
Fax: 01282 695 511
Email: [email protected]
Website: www.voltek.co.uk
© Voltek Automation Ltd. 1995/2011 IS2000IN.DOC : Rev 4 : QI
3

advertisement

Key Features

  • ATEX and IECEx approved and certified
  • 18m nominal detection range
  • 90° viewing angle
  • Simple 4 wire connection
  • Maintenance free
  • Very high immunity against RFI, EMI and reflected sunlight
  • High gain fresnel optics provide true volumetric coverage of the detection area
  • IP 67 dust & water tight enclosure

Frequently Answers and Questions

How does the IS2000 MK1 work?
The IS2000 MK1 detects infrared energy (body heat) from moving objects. It splits the area into detection zones, and when a person moves from one zone to another, the sensor outputs a signal. High quality components, sophisticated filters and noise-free amplifiers ensure valid alarms are recognized.
What is the IS2000 MK1’s detection range?
The IS2000 MK1 has a nominal detection range of 18 meters.
Where can I find the IS2000 MK1 operating temperature range?
The operating temperature range for this device is -20°C to +40°C. However, this may differ from what is specified in the IS2000 brochure.
What is the warranty period for the IS2000 MK1?
The IS2000 MK1 has a 1 year parts and labor warranty.
Can I connect the IS2000 MK1 to my existing alarm system?
Yes, the IS2000 MK1 can be connected to your existing alarm system to warn of an intruder in a hazardous area.
How do I install the IS2000 MK1?
Installation must be performed by engineers with experience working in hazardous areas. You can find detailed instructions in this document.