- Home
- Domestic appliances
- Large home appliances
- Water heaters & boilers
- Lennox
- MCR 322 PK
- User Guide
- 24 Pages
Lennox MCR 102 SK, MCR 132 SK, MCR 162 SK, MCR 192 PK, MCR 232 PK, MCR 262 PK, MCR 322 PK liquid chiller Application guide
Below you will find brief information for liquid chiller MCR 102 SK, liquid chiller MCR 132 SK, liquid chiller MCR 162 SK, liquid chiller MCR 192 PK, liquid chiller MCR 232 PK, liquid chiller MCR 262 PK, liquid chiller MCR 322 PK. The MCR chillers are a perfect combination with our line of HVAC systems and offer a variety of features such as capacity control, antifreeze protection, optional parts for sound-insulated compressor compartments and more. The systems are compact, quiet and use the most advanced technology in order to meet the strictest requirements for reliability and safety. These systems also include a CLIMATICâ„¢ II microprocessor which provides control and operating information such as water, air and refrigerant temperatures, diagnostic per circuit, and adjustment of temperature.
advertisement
Assistant Bot
Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.
OMKEERBARE WATERKOELMACHINE LUCHTGEKOELDE CONDENSOR REVERSIBLE LIQUID CHILLER AIR COOLED CONDENSER MCR Dutch-English/01-2002 INHOUD CONTENTS ! Inleiding en beschrijving van de onderdelen Introduction and description of the components ................................... 2 ! Beschrijving van de standaardoptie Standard option description .................................................................. 4 ! MCR-prestatietabellen - Koelmodus MCR Performance tables - Cooling mode ............................................ 7 ! MCR-prestatietabellen - Verwarmingsmodus MCR Performance tables - Heating mode ............................................ 9 ! Technische gegevens Technical data ..................................................................................... 13 ! Elektrische gegevens Electrical data ...................................................................................... 14 ! Waterdrukverlies Water pressure drop ........................................................................... 15 ! Afmetingen Dimensional data ................................................................................ 16 ! Geluidsniveaus Noise levels ......................................................................................... 18 ! Werkingsgebied Operating limits ................................................................................... 19 Onze producten voldoen aan de Europese normen. Our products comply with the European standards. De fabricage van MCR voldoet aan het ISO 9001-kwaliteitscontrolesysteem. Een kopie van het certificaat wordt op verzoek toegezonden. The manufacturing of MCR answer to ISO 9001 control quality system. A copy of the certificat can be get on request. AFAQ N° 1993/1009b De specificaties en technische gegevens in deze brochure zijn bedoeld ter informatie. De fabrikant behoudt zich het recht voor deze gegevens aan te passen zonder voorafgaande kennisgeving of verplichting om de gegevens op dezelfde wijze aan te passen als bij eerder geleverde apparatuur. The specifications and technical characteristics in this booklet are given for information purposes. The manufacturer reserves the right to modify them without prior notice or obligation to modify in a similar manner, the equipments previously supplied. MCR •1• INLEIDING - BESCHRIJVING VAN DE ONDERDELEN INTRODUCTION - DESCRIPTION OF COMPONENTS De waterkoelmachines met dubbele werking model MCR vormen een perfecte combinatie met onze lijn HVAC-systemen. De productie van MCR-waterkoelmachines voldoet aan de Europese normen. De machines voldoen aan het ISO 9001kwaliteitscontrolesysteem. Om er zeker van te zijn dat het product dat de klant heeft besteld, voldoet aan de kwaliteitsnorm voor onze producten, worden de koeling en het elektrische systeem van MCRwaterkoelmachines vóór verzending systematisch getest op de proefstand. MCR-waterkoelmachines, die worden gekenmerkt door kleine afmetingen en een stille werking, maken gebruik van de meest geavanceerde technologie om te voldoen aan de strengste betrouwbaarheids- en veiligheidseisen. MCR-machines zijn uitgerust met semi-hermetische zuigercompressoren (MCR P) of hermetische scrollcompressoren (MCR S). De apparaten werken met het koudemiddel R407C. The MCR air to water reverse cycle liquid chillers perfectly combine with our complete range of HVAC system. The manufacturing of MCR chillers complies with the European standards. These chillers answer to ISO 9001 control quality system. In order to meet the final conformity of finished product with the customers' order, the correct operation refrigeration and electrical systems of MCR chillers are systematically tested in the test station before shipping. COMPRESSOR COMPRESSOR - Hermetische scrollcompressor of semi-hermetische zuigercompressor - Zuiggasgekoelde geïntegreerde motor - Carterverwarming - Directe start (DOL) - Persgasdemper (MCR P-apparaten) - Persgasafsluiter (MCR P-apparaten) - Bevestigd op zeer efficiënte trillingsdempers van celpolyurethaan - Hermetic scroll or semi-hermetic reciprocating type VERDAMPER EVAPORATOR - U-vormige, verwisselbare buizenbundel met buizen voorzien van inwendige groeven, die op mechanische wijze zijn uitgezet in een pijpplaat, koperen schotten en een stalen mantel - Ontluchtingsventiel en aftap - Thermische isolatie met hoogwaardig schuimplastic (dikte 12,7 mm) - U-shaped, removable tube bundle, manufactured with internally grooved tubes mechanically expanded into a steel tube sheet, brass baffles, and a steel shell - Air vent and water drain - Thermal insulation by top grade plastic foam (thickness 12,7 mm) CONDENSOR CONDENSER - Uitgezette koperen buizen en zeer efficiënte aluminium geribde lamellen - Axiaalventilatoren - Directe aandrijving - Expanded copper tubes and high efficiency aluminium fins KOELCIRCUITS REFRIGERATION CIRCUITS - Vloeistofvat met 2 isolerende magneetventielen (bovenstroomse en onderstroomse zijde) - Zuiggasaccumulator - 4-weg magneetventiel klep - Filterdroger - Thermostatisch expansieventiel (2 per circuit): 1 voor koelcyclus + 1 voor verwarmingscyclus. Beide met gelijke doorlaat) - Vloeistofmagneetventielen (alleen op MCR P-apparaten) - Vloeistofkijkglas - 1 hogedrukschakelaar per circuit - HP/LP-druksensoren - Liquid receiver with 2 isolating solenoid valves (upstream and downstream sides) - Suction accumulator - 4-way solenoid valve - Filter-drier - Thermostatic expansion valve (2 per circuit : 1 for cooling cycle + 1 for heating cycle. Same size for both) ELEKTRISCH PANEEL ELECTRICAL PANEL - Waterdicht (IP 55), scharnierdeur - Voeding 400V/3/50 Hz + T - Voeding stuurcircuit 230V/1/50Hz (gegenereerd door stuurstroomtrafo) - Gescheiden voeding 230V/1/50Hz (voor carterverwarming en antivriesverwarming) - Stroomschakelaar stuurcircuit - Bedrading in overeenstemming met standaard EN 60204-1 - IP 55 watertightness, hinged door - Power source supply 400V/3/50Hz + T - Control circuit power supply 230V/1/50Hz (generated by control transformer) - Separated supply 230V/1/50Hz (for crankcase heaters and antifreeze heaters) - Control circuit power switch - Unit wiring in compliance with standard EN 60204-1 • 2 • With low dimensions and quiet operation, the MCR chillers make use of the finest in technology to satisfy the strictest reliability and safety requirements. MCR units are equipped with semi-hermetic reciprocating (MCR P) or hermetic scroll type compressors (MCR S). They operate with refrigerant R407C. - Suction gas cooled integral motor Crankcase heater Direct start-up (DOL) Discharge silencer (MCR P units) Discharge valve (MCR P units) Mounted on high efficiency cellular polyurethane vibration absorbers - Axial fans - Direct drive - Liquid solenoid valves (only on MCR P units) Liquid sight glass 1 high pressure switch per circuit HP/LP pressure sensors MCR CHASSIS CHASSIS - - Gegalvaniseerd stalen chassis (gezet en gelast) Polyesterverf - kleur RAL 9002 Rooster voor condensorbatterij Apparaat wordt opgetild en verplaatst via het frame Formed and welded steel galvanized chassis Polyester paint - Colour RAL 9002 Condenser coil grill Unit lifting and handling via the base frame BEDIENING CONTROL - Bediening en controle door CLIMATIC™ II-microprocessor, KP02-display - Aflezing van temperatuur van water, lucht en koudemiddel - Aflezing van de koudemiddeldruk - Alarmsignalen - Diagnose per circuit - Aanpassing van temperatuurwaarden en parameters aan bedrijfsomstandigheden - Urenteller en dagelijkse balans van bedrijfstijd voor elke compressor door "first in/first out"-schakeling - Signalering op afstand - Op afstand resetten van vaste waarden (optie) - Capaciteitsregeling werkend op de waterintredetemperatuur, met nivellering door uittredetemperatuur - Antivriesbescherming (als er geen glycol aan het water is toegevoegd) - Control and safe operation by CLIMATIC™ II microprocessor, KP02 display - Reading of water, air and refrigerant temperatures - Reading of refrigerant pressures - Alarm signalling - Diagnostic per circuit - Adjustment of temperature setpoints and parameters adapted to operating conditions - Hour counter and daily balance of operating time for each compressor by "first in/first out" permutation - Remote default signal - Remote setpoint set-back (option) - Capacity control in accordance with water inlet temperature with balancing by outlet temperature - Antifreeze protection (if water is not glycolated) OPTIES KOUDEMIDDELCIRCUIT REFRIGERATING OPTIONS - - Stromingsschakelaar gekoeld water Hogedruk- en lagedrukmanometers Verdamper antivriesverwarming Versterkte verdamperisolatie (dikte 26,4 mm) Oliedrukmeter (alleen op MCR P-apparaten) Eén extra capaciteitsbegrenzer (alleen op MCR P-apparaten) Handbediende zuigafsluiter (alleen op MCR P-apparaten) TÜV/VDE- en STEK-normen Chilled water flow switch High and low pressure gauges Evaporator antifreeze heater Re-inforced evaporator insulation (thickness 26,4 mm) Oil gauge (on MCR P units only) One extra capacity reducer (on MCR P units only) Suction manual isolating valve (on MCR P units only) TUV/VDE and STEK norms ELEKTRISCHE OPTIES ELECTRICAL OPTIONS - - Grafisch display KP 07 Hoofdschakelaar Storingslampje voor koudemiddelcircuit 400/230V-transformator voor de voeding van de carterverwarming van de compressor en de antivriesverwarmer - Part-winding start van de compressoren (alleen op MCR P-apparaten) KP 07 graphic display Main switch Refrigerant circuit default signaller 400/230V transformer for electrical supply of compressor crankcase heater and antifreeze heater - Compressors part-winding start (on MCR P units only) OPTIES VOOR GELUIDSISOLATIE (SI-VERSIE) LOW NOISE OPTION (SI VERSION) - Laag toerental van de ventilator (550 tpm) - Geluidsisolatie compressoren met panelen van 20/10 mm en geluidsisolerend schuimrubber - Low fan rotation speed (550 RPM) - Compressor noise insulation by 20/10 mm panels + sound proofing foam OVERIGE OPTIES MISCELLAENOUS OPTIONS - - Beschermroosters Sierlijsten Trillingdempers Bescherming van batterijen met BLYGOLD PLUS MCR Anti-intrusion grill Embellish posts Vibration absorbers "BLYGOLD PLUS" protection on coils •3• GEGEVENS STANDAARDOPTIES VAN MCR MCR STANDARD OPTIONS DETAILS Stromingsschakelaar gekoeld water Chilled water flow switch Afhankelijk van het type apparaat zijn twee typen stromingsschakelaars beschikbaar: verschildrukschakelaar of vaanschakelaar. Bij keuze van een verschildrukschakelaar moet ook de optie 'antivriesverwarmer op stromingsschakelaar' worden gekozen voor gebruik bij temperaturen lager dan 0°C. Deze schakelaar wordt gemonteerd en aangesloten geleverd en is in de fabriek getest. De vaanschakelaar wordt los geleverd en dient door de klant te worden bevestigd in het gekoelde water als het apparaat uitgeschakeld is. Ook moet de klant de stromingsschakelaar direct aansluiten op de beschikbare bedieningspaneelaansluitingen. Als een waterkoelmachine wordt gebruikt zonder stromingsschakelaar, bevriest de verdamper. Als de waterkoelmachine wordt gebruikt met een te lage waterhoeveelheid, vervalt de garantie indien er geen stromingsschakelaar in het koelwatersysteem aanwezig is. According to the unit type, 2 different flow switch types of switch are available : differential flow switch or a paddle flow switch. HP/LP-drukmanometers HP/LP pressure gauge Oliemeter gevuld met glycerine waarmee de verdampingsdruk en de condensatiedruk van elk koudemiddelcircuit wordt gemeten. Alle compressoren zijn voorzien van een meter. Dit zijn gecombineerde drukmeters die de temperatuur van de verschillende verzadigde koudemiddelen weergeven. De meters hebben kleurcodes, zodat ze eenvoudig zijn af te lezen: blauw voor lage druk en rood voor hoge druk. Deze informatie wordt ook aangegeven op de CLIMATIC™ II-besturing. Schaf geen functionaliteit aan die het apparaat al heeft, om onnodige extra kosten te voorkomen. Als een bestek gegevens over hoge of lage druk vereist, zijn die beschikbaar op de Climatic II-besturing. Het is niet nodig om extra meters te monteren. De concurrentie monteert meters die niet met glycerine zijn gevuld en niet bestand zijn tegen de variërende gasdruk. Glycerized oil gauge that measures the evaporating Low pressure (LP) and condensing high pressure (HP) on each refrigerant circuit. Gauges are mounted locally at each compressor The gauges are compound gauges that display the saturated refrigerant temperature for various refrigerants used. Gauges are color coded for easy reference Blue is LP and red is HP. The same information is available on the CLIMATIC™ II controller. Be careful not to duplicate functions and add unnecessary costs to a unit. If a specification asks for display of High and low pressure then this is available from the Climatic II controller and it is not necessary to add gauges. Competitors will add gauges that are not glycerin filled and these quickly fail due to gas pulsation. Verdamper antivriesverwarming Evaporator antifreeze heater Het verdampervat is omwikkeld met weerstandsverhittingsband, zodat de verdamper niet bevriest bij temperaturen tot -20°C. Geregeld door een thermostaat op het hoofdpaneel. In de winter is hiervoor een elektrische voeding nodig. Als het apparaat is uitgeschakeld met de hoofdschakelaar, krijgt de antivriesverwarmer geen stroom. Onder deze omstandigheden wordt gebruik van een aparte voedingsbron aanbevolen. Externe wateraansluitingen die op het apparaat zijn aangesloten, zijn niet beschermd tegen lage temperaturen. Hiervoor zijn extra maatregelen tegen bevriezing nodig. Als de juiste hoeveelheid glycol wordt gebruikt, hoeft u geen extra maatregelen te nemen. Resistance heating tape is wrapped around the evaporator barrel to help protect the evaporator from freezing down to 20°C. Controlled by a thermostat mounted in the main panel. Note this requires an electrical supply during winter operation. If mains switch is off then there is no supply to the anti freeze heater. A separate supply is recommended under these circumstances. This device will not protect external water pipework connected to the unit and additional frost protection measures are required. Versterkte verdamperisolatie Reinforced evaporator insulation Extra thermische isolatie van de verdamper: de isolatie wordt uitgebreid van 12,7 mm naar 26 mm met waterbestendig schuimrubber met gesloten cellen. Classificatie voor brandgevaar: M1. Oversized thermal insulation of the evaporator increases the insulation from12,7mm to 26 mm closed cell foam that is resistant to water. Classification for fire : M1. Oliedrukmeter Oil gauge Oliemeter gevuld met glycerine die de oliedruk van de compressor meet. Deze optie is alleen beschikbaar bij zuigercompressoren. Glycerized oil gauge that measures the oil pressure of the compressor. This option is only available on reciprocating compressors. Eén extra capaciteitsregeltrap (alleen bij zuigercompressoren) One extra capacity reducter (reciprocating compressors only) Toevoeging van een extra capaciteitsregelrtap, zodat werking op doellast wordt uitgebreid. The addition of a futher capcity reduction step to help improve the part load operation. • 4 • In case a differential flow switch has been selected, it is necessary to propose the option “antifreeze heater on flow switch” for operating at temperatures lower than 0°C. This switch comes piped and fitted on the evaporator and is tested by the factory. The paddle switch is supplied loose for fitting in the CHILLED water off line by the customer. It is also required that the customer wire the flow switch directly back to the control panel terminals provided. If a chiller is operated with out a flow switch then Freezing of the evaporator will occur if the chiller is operated with no water flow warranty will be voided if no flow switch is present in the chilled water system This option can be omitted in case of a correct proportion of glycol. MCR GEGEVENS STANDAARDOPTIES VAN MCR (vervolg) - MCR STANDARD OPTIONS DETAILS (cont'd) Handbediende zuigafsluiter (alleen bij zuigercompressoren) Suction manual isolating valve (reciprocating compressors only) Koudemiddelisolatie / stopklep. Aangebracht in elk koudemiddelcircuit. Hierdoor kan met de compressor het koudemiddel in de condensor worden gepompt. Als de compressor is voorzien van een drukterugslagklep, kan de compressor van het systeem worden geïsoleerd voor onderhoudswerk. Refrigerant isolation / stop valve. Fitted on each refrigerant circuit. This will allow the compressor to pump down the refrigerant charge into the condenser and if the compressor is fitted with a discharge check valve allow the compressor to be isolated from the system for maintenance work. TÜV/VDE TUV/VDE Apparaten voldoen aan de TÜV/VDE-norm (elektrisch onderdelen, drukapparaten, veiligheidskleppen). Units manufacturing according to the TÜV/VDE norm (electrical components, pressure devices, safety valves...). STEK STEK Apparaten voldoen aan de STEK-norm (elektrisch onderdelen, drukapparaten, veiligheidskleppen). Units manufacturing according to the STEK norm (electrical components, pressure devices, safety valves...). Grafisch display KP07 KP07 Graphic Display Het grafische display KP07 CLIMATIC™ II vervangt de KP02 en bestaat uit een compleet LCD-scherm en een toetsenbord als gebruikersinterface. Hierdoor zijn meer functies en bedieningsopties beschikbaar dan bij de KP02. The KP07 CLIMATIC™ II graphic display replaces the KP02 and give a full LCD display and key board for customer interface. This offers additional functionality and control features that are not on the KP02. Hoofdschakelaar Main ON/OFF switch Hiermee kan de 3-fasenhoofdvoeding worden uitgeschakeld en geïsoleerd als de machine in bedrijf is of is gestopt. Als de transformator is toegepast, kunt u met deze schakelaar ook de stuurstroom en de antivriesverwarmers uitschakelen. WAARSCHUWING: als de hoofdschakelaar op de 'uit'-stand staat en er geen afzonderlijke voedingsbron voor de antivriesverwarmers is, kan bevriezing optreden. De hoofdschakelaar wordt geleverd met afgeschermde aansluitingen. De hoofdschakelaar wordt gebruikt om de spanning van het apparaat uit te schakelen, teneinde veilig met het elektrische systeem te kunnen werken. It allows the general cut-off and isolation of the main 3 phase power supply, either the machine is running or stopped. If the mains transformer is fitted this switch will also cut power from the control and anti freeze Heaters. CAUTION if the mains switch is in the off position and a separate power supply is NOT provided to the anti freeze heaters Freezing can occur. Relais voor storingssignalering Alarm signaling relay Relais met potentiaal vrij contact voor storingsmelding van de compressor of het standaardcircuit (op apparaten met 2 compressoren: één extern signaal per compressor, op apparaten met 4 compressoren: één extern signaal per circuit). CLIMATIC™: algemene storingsmelding. Dry contact relay allowing the remote alarm of compressor or circuit default (on units equipped with 2 compressors : one remote alarm per compressor, on units equipped with 4 compressors : one remote alarm per circuit). CLIMATIC™ standard : general default. Transformator Mains Transformer Maakt de afzonderlijke voeding van 230V/1/50 Hz voor de carterverwarming van de compressor en de optionele antivriesverwarming van de verdamper overbodig. Zo kan worden volstaan met één voedingsaansluiting op de hoofdschakelaar. De stroom voor het stuurcircuit en de verwarmers wordt door de transformator geleverd. De transformator wordt compleet bedraad geleverd en is getest. Dankzij deze optie kunnen de installatiekosten worden beperkt en hoeft de klant geen nulleider aan te leggen. Avoids the separated power supply 230V/1/50Hz for the compressor crankcase heaters and the option antifreeze heater on evaporator. This enables the customer to make just one power connection at the main switch the remaining power to the control circuit and heaters is provided by the transformer. The mains transformer comes fully wired and tested This option can reduce a customers installation costs and does not require a customer to use a neutral cable. Part-winding start 400/3/50 (alleen bij zuigercompressoren) Part winding start 400/3/50 (reciprocating compressors only) Hiermee wordt het aanloopstroom verminderd, zodat spanningsval in het elektriciteitsnet van het apparaat wordt voorkomen en de bedrijfskosten bij maximale belasting worden beperkt. Elke compressormotor bestaat uit twee parallelle wikkelingen, die elk afzonderlijk zijn aangesloten als sterverbinding. Dankzij deze afzonderlijke aansluitingen kan een motor in twee fasen Reduces the start-up current, to prevent voltage drops in the electrical network of the installation and reduce maximum demand operating costs. MCR The mains switch is supplied with covers on the connections The mains switch is used to isolated power from the unit for safe working on the electrical system. Each compressor motor is made up of two parallel independent windings, each one being autonomously connected as “star-type connection”. These independent con•5• GEGEVENS STANDAARDOPTIES VAN MCR (vervolg) - MCR STANDARD OPTIONS DETAILS (cont'd) worden gestart: bij het starten wordt de eerste wikkeling geactiveerd en vlak daarop wordt de tweede wikkeling geactiveerd. Op deze manier wordt het stroomverbruik en de aanloopstroom beperkt. Deze optie kan worden aangeboden als de concurrentie een sterdriehoekstart biedt of als een sterdriehoekstart is vereist. Part-winding start biedt dezelfde voordelen als sterdriehoekstart. nections allow the motor to have a two stage staring sequence, on start the first winding is energized and a short time after the second winding is energized thus limiting the power consumption and starting current. This option can be offered when a competitor offer a star delta type start or a star delta start is required. Part winding start offers similar benefits to star delta starting. Compressorcompartiment met geluidsisolatie Compressor sound-insulated compartment Compartiment van Aluzinc-staal, afgeschermd met geluidsisolerend schuimrubber: PAE 28 mm, 3 kg/m2 massa, beschermingslagen, brandgevaarclassificatie M1. Compartment in Aluzinc steel, covered with sound-insulated foam : PAE 28 mm, 3 kg/m2 mass, protection films, fire classification M1. Laag toerental van de ventilator Low fan rotation speed 550 tpm-ventilatoren ter vervanging van standaardventilatoren (700 tpm). 550 RPM fans, replacing standard 700 RPM ones. Beschermingsroosters Anti intrusion grills Wanneer een apparaat in een niet veilige omgeving wordt geplaatst, wordt u aangeraden beschermingsroosters te bevestigen. Het onderste deel van het apparaat wordt afgesloten, zodat de onderdelen niet toegankelijk zijn. Deze roosters bieden geen volledige veiligheid. When a unit is installed in an area that is not secure then it is recommended that anti intrusion grills are fitted. These enclose the lower section of the unit to inhibit access to the components. These are only a deterants and will not provide total security. Sierlijsten Embellished posts Met dit pakket kunt u de buitenkant van de waterkoelmachine of de warmtepomp afwerken. Het pakket bevat metalen vulplaten en hoekstukken waarmee de waterkoelmachine en de warmtepomp kunnen worden afgewerkt en de hoeken kunnen worden afgerond. Zo krijgt de waterkoelmachine of de warmtepomp meer geverfde onderdelen en ziet deze er perfect afgewerkt uit. This is a kit that greatly improves the appearance of the chiller or heat pump. It consists of sheet metal fill and corner pieces so that the chiller or heat pump has a smooth appearance with rounded corners. The chiller or heat pump appearance is with more painted sections and looks very well finished. Trillingsdempers Anti-vibration mounts Trillingsdempers zijn vervaardigd van twee vlakke en parallelle delen, die door een rubber ring met elkaar zijn verbonden. Deze worden onder het apparaat bevestigd op de punten die op de technische tekeningen staan aangegeven. Hiermee wordt de overbrenging van trillingen naar de fundering beperkt en wordt het algemene geluidsniveau verlaagd. De diameter en sterkte zijn afhankelijk van het model. Worden ongemonteerd geleverd. Dit type is niet geschikt voor betonplaten. Elastic supports made of 2 flat and parallel frames, connected together via a rubber ring, fixed under the unit at the points specified by our technical drawings. Reduces the transmission of vibration to the ground and the general sound level. The diameter and strength vary in accordance with the model. Delivered not fitted. This type of mounts is not adapted to concrete slabs. Blygold-behandeling Blygold treatment Blygold-behandeling tegen corrosie van de condensorbatterijen. "Blygold" anticorrosion treatment of the condenser coils. Twee mogelijke toepassingen: - Zee-omgeving - Industriële omgeving (vluchtige oplosmiddellen). Toepassing op te geven bij plaatsing van de order. Two possible applications : - Sea atmosphere - Industrial atmosphere (solvent dissolved in air). Application to be specified when placing the order Alcoholthermometers voor in- en uittrede Inlet/outlet alcohol thermometers Meten de waterintrede- en uittredetemperatuur (worden los geleverd voor montage door derden) Measures the water inlet and outlet temperature (supplied loose for fitting by others) Standaardwatermanometer Simple water gauge Watermanometer meet de druk bij de in- en uittrede van de watercircuits. Water gauge measures the pressure on the inlet and outlet of the water circuits. Vloeistoffilter Strainer filter Het vloeistoffilter wordt in de waterintrede geplaatst om de verdamper te beschermen tegen mogelijke verontreiniging (filterfijnheid 80 micron). Dit filter wordt geadviseerd bij verdampers en is noodzakelijk bij platenwisselaars. Strainer filter to be installed upstream to the water inlet, to protect the evaporator from any possible impurities (80 microns efficiency). Recommended for shell and tube and must be fitted for Plate heat exchangers. • 6 • MCR PRESTATIETABELLEN - KOELMODUS PERFORMANCE TABLES - COOLING MODE VENTILATORTOERENTAL: 700 TPM FANS SPEED : 700 RPM Luchtintredetemperatuur Air inlet temperature Wateruittrede S Temperatuur PE S °C TY YPE T Water outlet Temperature MCR 102 SK MCR 132 SK MCR 162 SK MCR 192 PK MCR 232 PK MCR 262 PK MCR 322 PK 5 7 9 11 5 7 9 11 5 7 9 11 5 7 9 11 5 7 9 11 5 7 9 11 5 7 9 11 Qo : Koelvermogen (kW) Cooling capacity (kW) XXX MCR ∆T water = 5°C Water ∆T = 5°C 28°C Qo 106,8 114,4 122,1 129,8 133,1 141,9 150,7 160,6 168,3 180,4 193,6 206,8 196,9 211,2 226,6 242,0 232,1 248,6 266,2 284,9 264,0 282,7 302,5 322,3 327,8 350,9 375,1 400,4 30°C P 33,4 33,9 34,4 35,0 43,3 44,2 45,2 46,2 48,5 49,0 49,4 49,9 62,3 64,4 66,4 68,4 74,3 76,8 79,3 81,8 89,5 92,8 96,2 99,5 107,0 110,0 114,0 118,0 P: Qo 104,6 112,2 119,9 127,6 129,8 138,6 147,4 157,3 165,0 177,1 189,2 202,4 190,3 204,6 220,0 235,4 225,5 242,0 259,6 277,2 257,4 275,0 294,8 314,6 320,1 342,1 366,3 390,5 P 34,8 35,3 35,9 36,4 45,0 46,0 47,0 48,0 50,4 50,9 51,4 51,9 63,7 65,8 67,9 70,0 76,0 78,7 81,2 83,8 91,2 94,7 98,1 102,0 109,0 113,0 117,0 120,0 32°C Qo 102,4 109,5 116,6 124,3 126,5 135,3 144,1 152,9 161,7 172,7 184,8 198,0 184,8 199,1 213,4 228,8 220,0 236,5 253,0 270,6 249,7 268,4 287,1 306,9 311,3 333,3 357,5 381,7 P 36,3 36,8 37,4 37,9 46,8 47,8 48,8 49,8 52,4 52,9 53,4 54,0 65,1 67,2 69,4 71,6 77,7 80,5 83,1 85,7 93,0 96,5 100,0 103,0 111,0 115,0 119,0 123,0 35°C Qo 98,9 105,7 113,3 121,0 121,0 129,8 138,6 147,4 156,2 167,2 179,3 191,4 177,1 190,3 204,6 220,0 210,1 226,6 243,1 260,7 239,8 258,5 276,1 295,9 299,2 320,1 343,2 367,4 Opgenomen vermogen compressoren (kW) Compressors power input (kW) P 38,6 39,2 39,7 40,3 49,6 50,6 51,6 52,7 55,5 56,1 56,7 57,2 67,0 69,2 71,5 73,8 80,3 83,1 85,9 88,6 95,5 99,1 103,0 106,0 115,0 119,0 123,0 127,0 39°C Qo 94,1 100,7 107,6 114,4 114,4 122,1 75,8 81,0 148,5 159,5 170,5 181,5 166,1 179,3 192,5 206,8 199,1 214,5 229,9 246,4 227,7 244,2 261,8 226,6 281,6 302,5 324,5 347,6 P 41,9 42,5 43,1 43,7 53,4 54,4 25,7 26,0 59,9 60,6 61,3 61,9 69,3 71,7 74,1 76,6 83,5 86,5 89,4 92,2 98,7 103,0 106,0 85,4 118,0 123,0 127,0 132,0 43°C Qo 89,1 54,3 58,4 62,6 61,9 66,7 71,5 76,6 140,8 150,7 161,7 172,7 155,1 167,2 180,4 194,7 188,1 161,7 173,8 187,0 172,7 185,9 200,2 214,5 264,0 284,9 246,4 264,0 P 45,4 22,3 22,5 22,6 27,1 27,4 27,8 28,1 64,7 65,5 66,3 67,0 71,4 73,9 76,5 79,1 86,6 70,2 72,4 74,6 79,9 82,8 85,6 88,4 122,0 126,0 104,0 107,0 Vervuilingsfactor Fouling factor : 0,44 m²C/kW XXX Werking bij hogedrukoffloading High pressure offloading operation •7• PRESTATIETABELLEN - KOELMODUS PERFORMANCE TABLES - COOLING MODE VENTILATORTOERENTAL: 540 TPM FANS SPEED : 540 RPM S PE ES Y T YP T MCR 102 SK MCR 132 SK MCR 162 SK MCR 192 PK MCR 232 PK MCR 262 PK MCR 322 PK °C Water outlet Temperature 5 7 9 11 5 7 9 11 5 7 9 11 5 7 9 11 5 7 9 11 5 7 9 11 5 7 9 11 Qo : Koelvermogen (kW) Cooling capacity (kW) XXX • 8 • Luchtintredetemperatuur Air inlet temperature Wateruittrede Temperatuur ∆T water = 5°C Water ∆T = 5°C 28°C Qo 106,4 113,3 121,0 129,8 132,0 140,8 149,6 158,4 168,3 180,4 192,5 205,7 195,8 210,1 224,4 239,8 229,9 247,5 264,0 282,7 261,8 280,5 299,2 319,0 325,6 348,7 372,9 397,1 30°C P 32,8 33,3 33,8 34,4 42,9 43,9 44,9 46 46,6 47,2 47,7 48,2 60,6 62,6 64,7 66,8 72,7 75,3 77,9 80,4 88 91,4 94,9 98,3 105 108 112 115 P: Qo 104,2 111,1 118,8 126,5 128,7 137,5 146,3 155,1 165,0 176,0 189,2 201,3 190,3 204,6 218,9 234,3 224,4 240,9 257,4 275,0 255,2 272,8 292,6 311,3 317,9 339,9 364,1 388,3 P 34,2 34,7 35,3 35,9 44,6 45,6 46,7 47,8 48,5 49,1 49,6 50,2 61,9 64,1 66,2 68,4 74,4 77,1 79,8 82,4 89,7 93,2 96,8 100 107 111 114 118 32°C Qo 101,9 108,9 116,6 124,3 125,4 134,2 143,0 151,8 160,6 172,7 184,8 196,9 184,8 198,0 212,3 227,7 217,8 234,3 250,8 268,4 248,6 266,2 284,9 303,6 309,1 332,2 355,3 378,4 P 35,6 36,2 36,8 37,4 46,4 47,4 48,5 49,6 50,5 51,1 51,7 52,3 63,2 65,5 67,7 69,9 76,1 78,9 81,6 84,3 91,4 95 98,6 102 109 113 117 121 35°C Qo 98,3 105,2 112,2 119,9 119,9 128,7 137,5 145,2 155,1 167,2 178,2 190,3 176,0 190,3 203,5 217,8 209,0 225,5 242,0 258,5 238,7 256,3 273,9 292,6 297,0 319,0 341,0 364,1 Opgenomen vermogen compressoren (kW) Compressors power input (kW) 39°C P 37,9 38,5 39,1 39,8 49,2 50,2 51,3 52,5 53,7 54,3 54,9 55,5 65,1 67,4 69,8 72,1 78,6 81,5 84,3 87,1 93,9 97,6 101 105 112 116 120 124 Qo 93,6 100,1 106,9 114,4 113,3 70,5 75,6 80,7 148,5 158,4 169,4 181,5 165,0 178,2 191,4 205,7 198,0 213,4 228,8 245,3 225,5 243,1 210,1 225,5 280,5 300,3 322,3 344,3 P 41,2 41,9 42,5 43,2 52,9 24,5 24,8 25,1 58,1 58,8 59,5 60,2 67,4 69,9 72,3 74,8 81,8 84,8 87,8 90,7 97,1 101 81 83,7 116 120 125 129 43°C Qo 50,6 54,3 58,4 62,6 61,9 66,6 71,4 76,3 140,8 150,7 160,6 171,6 154,0 167,2 179,3 193,6 187,0 160,6 172,7 185,9 171,6 184,8 199,1 213,4 262,9 227,7 245,3 262,9 P 21,1 21,3 21,5 21,6 26,2 26,5 26,8 27,2 62,8 63,7 64,5 65,3 69,5 72,1 74,7 77,3 84,8 68,4 70,6 72,8 78,1 81 83,9 86,7 119 97,4 101 104 Vervuilingsfactor Fouling factor : 0,44 m²C/kW XXX Werking bij hogedrukafvoer High pressure offloading operation MCR PRESTATIETABELLEN - VERWARMINGSMODUS PERFORMANCE TABLES - HEATING MODE VENTILATORTOERENTAL: 700 TPM - FANS SPEED : 700 RPM MCR 52SK -> MCR 162 SK S PE ES Y T YP T Uittredetemperatuur warm water Hot water outlet temperature Luchtintrede temperatuur 35°C 40°C 45°C 50°C °C Air inlet temperature Qc P Qc P Qc P Qc P MCR 102 SK 15 11 7 3 -1 -5 -8 -10 169,4 151,8 136,4 122,1 109,5 98,1 90,6 86,0 34,9 34,6 34,2 33,7 33,3 32,8 32,5 32,3 167,2 150,7 135,3 121,0 109,2 98,5 91,3 87,0 38,6 38,1 37,7 37,2 36,6 36,1 35,6 35,3 165,0 148,5 134,2 121,0 109,3 99,2 - 42,6 42,1 41,5 40,9 40,3 39,6 - 87,5 78,9 133,1 121,0 109,9 - 23,5 23,5 45,7 45 44,2 - MCR 132 SK 15 11 7 3 -1 -5 -8 -10 204,6 183,7 163,9 146,3 129,8 116,6 106,8 101,0 40,3 39,7 39,1 38,5 37,9 37,2 36,8 36,5 201,3 180,4 161,7 145,2 129,8 116,6 107,1 101,5 44,3 43,7 43 42,4 41,7 40,9 40,4 40 198,0 178,2 160,6 144,1 129,8 116,6 - 48,8 48,1 47,3 46,6 45,7 44,8 - 195,8 176,0 158,4 143,0 128,7 - 53,7 52,9 52 51,1 50,1 - 15 11 7 3 -1 -5 -8 -10 269,5 243,1 217,8 194,7 173,8 155,1 143,0 135,3 53,2 53,2 52,9 52,5 52 51,3 50,7 50,3 265,1 238,7 214,5 192,5 172,7 154,0 141,9 134,2 58,4 58,3 58 57,5 56,8 55,9 55,2 54,6 259,6 234,3 211,2 190,3 170,5 154,0 141,9 - 64,2 64 63,6 62,9 62 60,9 60 - 135,3 231,0 209,0 188,1 170,5 - 36,6 70,3 69,7 68,8 67,7 - MCR 162 SK Qo : Koelvermogen (kW) Cooling capacity (kW) XXX MCR ∆T water = 5°C Water ∆T = 5°C P: Opgenomen vermogen compressoren (kW) Compressors power input (kW) Vervuilingsfactor Fouling factor : 0,44 m²C/kW XXX Werking bij hogedrukafvoer High pressure offloading operation •9• PRESTATIETABELLEN - VERWARMINGSMODUS PERFORMANCE TABLES - HEATING MODE VENTILATORTOERENTAL: 700 TPM - FANS SPEED : 700 RPM MCR 192 PK -> MCR 322 PK S PE ES Y T YP T MCR 192 PK MCR 232 PK MCR 262 PK MCR 322 PK Uittredetemperatuur warm water Hot water outlet temperature 40°C 45°C Luchtintrede temperatuur °C Air inlet temperature 35°C Qc P Qc P Qc 15 322,3 69,1 311,3 73,4 300,3 11 284,9 65,6 275,0 69,4 265,1 7 250,8 62,2 242,0 65,5 233,2 3 -1 220,0 191,4 58,8 55,4 212,3 184,8 61,7 58 203,5 177,1 -5 166,1 52 159,5 54,3 -8 148,5 49,4 143,0 51,5 -10 137,5 47,6 132,0 15 11 377,3 333,3 78,9 75,3 7 293,7 3 256,3 -1 -5 50°C P Qc P 77,4 289,3 81,1 72,9 254,1 76,1 68,6 223,3 71,4 64,4 60,3 194,7 168,3 66,8 62,4 152,9 56,3 145,2 58,1 136,4 53,3 129,8 54,9 49,6 126,5 51,3 119,9 52,8 367,4 324,5 78,9 75,3 356,4 314,6 89,6 85 345,4 305,8 94,5 89,5 71,5 284,9 71,5 277,2 80,3 268,4 84,4 67,5 249,7 67,5 243,1 75,4 235,4 79,1 223,3 63,2 217,8 63,2 211,2 70,4 205,7 73,7 193,6 58,6 189,2 58,6 183,7 65,1 - - -8 173,8 54,9 169,4 54,9 - - - - -10 - - - - - - - - 15 434,5 94,2 422,4 100 410,3 105,6 317,9 88,3 11 383,9 89,3 374,0 94,5 363,0 99,5 352,0 104,2 7 337,7 84,3 328,9 89 319,0 93,5 310,2 97,7 3 295,9 79,2 287,1 83,4 279,4 87,5 271,7 91,3 -1 257,4 74 250,8 77,8 244,2 81,4 237,6 84,9 -5 -8 224,4 201,3 68,6 64,4 218,9 196,9 72 67,6 - - - - -10 - - - - - - - - 15 539,0 119 523,6 127 507,1 133 390,5 111 11 478,5 113 464,2 119 449,9 125 345,4 105 7 423,5 107 410,3 112 396,0 117 381,7 122 3 -1 372,9 326,7 101 94 360,8 315,7 105 98 347,6 303,6 109 101 333,3 290,4 113 104 -5 284,9 88 273,9 91 262,9 93 251,9 95 -8 255,2 83 245,3 85 235,4 87 224,4 89 -10 237,6 80 227,7 82 217,8 83 207,9 84 Qc : Verwarmingscapaciteit (kW) Heating capacity (kW) P: Opgenomen vermogen compressoren (kW) Compressors power input (kW) Vervuilingsfactor Fouling factor : 0,44 m²C/kW Capaciteitsgegevens onder gegeven bedrijfsomstandigheden, zonder verwijzing naar ontdooien. Capacity data for given operating conditions, without any reference to defrosting. XXX • 10 • ∆T water = 5°C Water ∆T = 5°C XXX ∆T water = 6°C Water ∆T = 6°C XXX Werking bij hogedrukafvoer High pressure offloading operation MCR PRESTATIETABELLEN - VERWARMINGSMODUS PERFORMANCE TABLES - HEATING MODE VENTILATORTOERENTAL: 540 TPM - FANS SPEED : 540 RPM MCR 52SK -> MCR 162 SK S PE S TY YPE T MCR 102 SK MCR 132 SK MCR 162 SK Uittredetemperatuur warm water Hot water outlet temperature Luchtintrede temperatuur 35°C 40°C 45°C 50°C °C Air inlet temperature Qc P Qc P Qc P Qc P 15 11 7 3 -1 -5 -8 -10 15 11 7 3 -1 -5 -8 -10 168,3 150,7 135,3 121,0 108,6 97,5 90,0 85,5 202,4 181,5 161,7 144,1 128,7 115,5 105,8 100,2 33,9 33,5 33,1 32,7 32,3 31,8 31,5 31,2 39,2 38,6 38 37,4 36,8 36,2 35,7 35,4 166,1 149,6 134,2 121,0 108,5 97,8 90,8 86,5 199,1 179,3 160,6 143,0 128,7 115,5 106,3 100,8 37,5 37,1 36,6 36,1 35,6 35 34,6 34,3 43,2 42,6 42 41,3 40,6 39,9 39,3 38,9 163,9 147,4 133,1 119,9 108,7 98,7 196,9 177,1 158,4 143,0 128,7 115,5 - 41,6 41 40,5 39,9 39,2 38,5 47,7 47 46,3 45,5 44,6 43,8 - 87,2 78,7 132,0 119,9 109,2 193,6 174,9 157,3 141,9 127,6 - 22,5 22,5 44,7 44 43,2 52,7 51,8 51 50 49 - 15 11 7 3 -1 -5 -8 -10 268,4 240,9 216,7 193,6 172,7 154,0 141,9 134,2 51,2 51,1 50,9 50,5 50 49,3 48,7 48,2 262,9 237,6 213,4 191,4 171,6 152,9 140,8 133,1 56,4 56,3 56 55,4 54,7 53,9 53,1 52,6 258,5 233,2 210,1 189,2 170,5 152,9 140,8 - 62,2 62 61,5 60,8 60 58,9 57,9 - 135,3 229,9 207,9 188,1 169,4 - 34,6 68,3 67,7 66,8 65,6 - Qc : Verwarmingscapaciteit (kW) Heating capacity (kW) P: Opgenomen vermogen compressoren (kW) Compressors power input (kW) Vervuilingsfactor Fouling factor : 0,44 m²C/kW Capaciteitsgegevens onder gegeven bedrijfsomstandigheden, zonder verwijzing naar ontdooien. Capacity data for given operating conditions, without any reference to defrosting. XXX MCR ∆T water = 5°C Water ∆T = 5°C XXX ∆T water = 6°C Water ∆T = 6°C XXX Werking bij hogedrukafvoer High pressure offloading operation • 11 • PRESTATIETABELLEN - VERWARMINGSMODUS PERFORMANCE TABLES - HEATING MODE VENTILATORTOERENTAL: 540 TPM - FANS SPEED : 540 RPM MCR 192 PK -> MCR 322 PK Luchtintredetemperatuur Air inlet temperature 40°C 45°C Wateruittrede S Temperatuur PE ES Y °C T YP T Water outlet Temperature MCR 192 PK MCR 232 PK MCR 262 PK MCR 322 PK 35°C Qc P Qc P Qc 50°C P Qc P 15 320,1 66,9 309,1 71,2 298,1 75,2 287,1 78,9 11 282,7 63,4 272,8 67,2 262,9 70,7 253,0 73,9 7 248,6 60 239,8 63,3 231,0 66,4 222,2 69,1 3 -1 217,8 190,3 56,6 53,2 210,1 182,6 59,5 55,8 202,4 176,0 62,2 58,1 193,6 167,2 64,6 60,2 -5 165,0 49,8 158,4 52,1 151,8 54,1 145,2 55,9 -8 147,4 47,2 141,9 49,3 135,3 51,1 128,7 52,7 -10 136,4 45,4 130,9 47,4 125,4 49,1 118,8 50,6 15 11 374,0 330,0 76,6 73 363,0 321,2 82 77,9 353,1 312,4 87,3 82,7 342,1 302,5 92,2 87,2 7 290,4 69,2 282,7 73,7 275,0 78 267,3 82 3 254,1 65,2 247,5 69,2 240,9 73,1 234,3 76,8 -1 221,1 60,9 215,6 64,5 210,1 68 204,6 71,4 -5 192,5 56,3 187,0 59,6 - - - - -8 172,7 52,6 168,3 55,7 - - - - -10 - - - - - - - - 15 430,1 91,7 418,0 97,5 407,0 103 315,7 86,1 11 379,5 86,8 369,6 92 358,6 97 348,7 102 7 333,3 81,8 324,5 86,5 315,7 91 306,9 95,3 3 292,6 76,8 284,9 81 277,2 85 269,5 88,9 -1 255,2 71,5 248,6 75,3 242,0 79 235,4 82,5 -5 -8 222,2 199,1 66,2 62 215,6 194,7 69,6 65,2 - - - - -10 - - - - - - - - 15 533,5 116 519,2 123 502,7 130 388,3 108 11 474,1 110 460,9 116 445,5 122 343,2 101 7 419,1 103 407,0 109 392,7 114 378,4 118 3 -1 368,5 323,4 97,2 90,9 357,5 312,4 102 94,5 344,3 300,3 106 97,7 331,1 288,2 109 100 -5 281,6 84,5 271,7 87,3 260,7 89,8 249,7 91,8 -8 253,0 79,6 243,1 81,9 233,2 83,8 222,2 85,3 -10 235,4 76,2 225,5 78,2 216,7 79,8 205,7 80,9 Qc : Verwarmingscapaciteit (kW) Heating capacity (kW) P: Opgenomen vermogen compressoren (kW) Compressors power input (kW) Vervuilingsfactor Fouling factor : 0,44 m²C/kW Capaciteitsgegevens onder gegeven bedrijfsomstandigheden, zonder verwijzing naar ontdooien. Capacity data for given operating conditions, without any reference to defrosting. XXX • 12 • ∆T water = 5°C Water ∆T = 5°C XXX ∆T water = 6°C Water ∆T = 6°C XXX Werking bij hogedrukafvoer High pressure offloading operation MCR TECHNISCHE GEGEVENS TECHNICAL DATA COMPRESSOREN EN KOUDEMIDDELCIRCUITS - COMPRESSORS AND REFRIGERANT CIRCUITS TYPE - TYPE MCR 102 SK Type compressor Compressor type 132 SK 162 SK Scroll Aantal compressoren / Aantal circuits Number of compressors / Number of circuits Capaciteitsstappen per compressor Capacity steps for each compressor Koudemiddelvulling per circuit Refrigerant charge per circuit 4/2 4/2 4/2 % 0-25-50 75-100 0-25-50 75-100 0-25-50 75-100 kg 34 34 70 4 4 4 70 70 70 232 PK 262 PK 322 PK Olievulling per compressor Oil charge per compressor l Carterverwarming per compressor Crankcase heater per compressor W TYPE - TYPE MCR Type compressor Compressor type 192 PK Semi-hermetische zuigercompressor Semi-hermetic reciprocating type Aantal compressoren / Aantal circuits Number of compressors / Number of circuits 2/2 Capaciteitsstappen per compressor Capacity steps for each compressor % 0-33-50 83-100 Koudemiddelvulling per circuit Refrigerant charge per circuit kg 70 70 70 102 l 7,4 7,7 7,7 7,7 W 200 200 200 200 102 SK 132 SK 162 SK Olievulling per compressor Oil charge per compressor Carterverwarming per compressor Crankcase heater per compressor 0-38-50-88-100 VERDAMPERS - EVAPORATORS TYPE - TYPE MCR Aantal Number Waterinhoud Water volume Wateraansluitingen Water piping Testdruk - Bar Test pressure - Bar Testdruk in bedrijf - Bar Operating pressure - Bar TYPE - TYPE 1 dm 3 30 51 51 (1) DN 80 PN 16 DN 100 PN 16 DN 100 PN 16 Koudemiddel Refrigerant 64 64 64 Water - Water Koudemiddel 10 32 10 32 10 32 232 PK 262 PK 322 PK MCR 192 PK Aantal Number Waterinhoud Water volume Wateraansluitingen Water piping Testdruk - Bar Test pressure - Bar Testdruk in bedrijf - Bar Operating pressure - Bar MCR 1 dm 3 88 82 82 100 (1) DN 150 PN 16 DN 150 PN 16 DN 150 PN 16 DN 150 PN 16 Koudemiddel Refrigerant 64 64 64 64 Water - Water Koudemiddel 10 32 10 32 10 32 10 32 • 13 • TECHNISCHE GEGEVENS (vervolg) - TECHNICAL DATA (cont'd) CONDENSOR - CONDENSERS TYPE - TYPE MCR 102 SK Type ventilator Ventilation type 132 SK 162 SK Axiaal - directe koppeling Axial - Direct coupling Ventilator aantal Fan number 3 Luchthoeveelheid (m /u) Air flow rate (m3/h) 2 2 4 700 TPM 700 RPM 48 000 48 000 96 800 540 TPM 540 RPM 42 400 42 400 85 600 232 PK 262 PK 322 PK TYPE - TYPE MCR 192 PK Type ventilatie Ventilation type Axiaal - directe koppeling Axial - Direct coupling Ventilatornummer Fan number 3 Luchtstroomsnelheid (m /u) Air flow rate (m3/h) 700 TPM 700 RPM 540 TPM 540 RPM 4 4 4 6 96 800 96 800 96 800 144 000 85 600 85 600 85 600 127 200 ELEKTRISCHE GEGEVENS ELECTRICAL DATA TYPE - TYPE Max. vermogen Maxi power MCR 102 SK 132 SK 162 SK 192 PK 232 PK 262 PK 322 PK kW 48 59 72 92 106 125 153 Max. stroom Maxi current A 89 105 134 158 200 238 287 Aanloopstroom directe start Direct start up intensity A 210 255 315 435 545 655 775 Starten op deel wikkeling Part-Winding start A - - - 350 440 525 625 Maximale stroom en vermogen berekend met 400V/3/50 Hz voor compressorwerking bij +12/60°C Maximum current and power calculated at 400V/3/50Hz for compressor operation at +12/60°C • 14 • MCR WATERDRUKVERLIES WATER PRESSURE DROP kPa 20 D E 10 A 9 8 B Drukverlies (KPa) Pressure drop (KPa) 7 C 6 5 4 3 2 1 5 6 7 8 9 10 20 30 40 50 60 70 80 90 100 m³/h Waterstroomsnelheid (m3/u) Water flow rate (m3/h) VERDAMPERS EVAPORATORS MCR Type Type MCR Kromme Curve Maximale waterstroomsnelheid Maxi water flow rate m3/h 102 S B 23,1 132 S C 38,9 162 S C 38,9 192 P D 89,3 232 P D 89,3 262 P D 89,3 322 P E 89,3 • 15 • AFMETINGEN DIMENSIONAL DATA 1 2173 1000 C E S D2/G2 G1/G2 D1/D2 30 30 1160 60 D1/G1 315 333 2600 315 60 A B E S 3563 1220 2 1301 2193 1000 C E S G1/G2/G3/G4 D1/D2/D3/D4 60 30 60 1160 D4/G4 500 D3/G3 D2/G2 1500 D1G1 1500 A 30 383 500 1500 B S E 1220 5883 2317 1000 2176 3 C E S G1/G2/G3/G4 D1/D2/D3/D4 60 60 30 2263 30 D4/G4 D4/G4 1200 245 A D4/G4 1200 1200 726 B E 2323 D4/G4 S 4573 Hoofdschakelaar is optioneel Main switch is an option • 16 • MCR AFMETINGEN (vervolg) - DIMENSIONAL DATA (cont'd) TYPE - TYPE MCR Tekening - Drawing 102 S 132 S 162 S 192 P 232 P 262 P 322 P 1 1 2 2 2 2 3 A mm 970 970 3245 3175 3175 3175 860 B mm 1800 1795 1795 1755 1755 1755 2255 C mm 280 340 360 425 425 425 405 GEWICHT (standaard MCR = is zonder geluidsisolatie) - WEIGHTS (standard MCR = without sound insulation) TYPE - TYPE MCR 102 S 132 S 162 S 192 P 232 P 262 P 322 P Gewicht zonder water Weight without water kg 1352 1377 2308 2445 2604 2644 3352 Bedrijfsgewicht Operating weight kg 1394 1419 2424 2564 2720 2760 3494 GEWICHT (MCR met geluidsisolatie) - WEIGHTS (MCR with sound insulation option) TYPE - TYPE MCR MCR 102 S 132 S 162 S 192 P 232 P 262 P 322 P Gewicht zonder water Weight without water kg 1594 1619 2709 2846 3005 3045 3542 Bedrijfsgewicht Operating weight kg 1636 1661 2825 2965 3121 3161 3684 • 17 • GELUIDSNIVEAUS NOISE LEVELS Standaard MCR-apparaten - Standard MCR units Spectrum per octaafband (dBA) Spectrum per octave band (dBA) 63 Hz 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz Globaal geluid sterkte dB(A) Global sound power dB(A) 102 SK 68 78 84 86 86 82 77 70 91 132 SK 68 78 84 86 85 85 78 74 92 162 SK 71 81 87 89 88 87 80 76 94 192 PK 71 81 87 89 90 87 82 80 95 232 PK 71 81 87 89 90 88 89 87 96 262 PK 71 81 87 89 90 88 89 88 97 322 PK 71 81 87 89 92 89 82 77 96 MCR MCR-apparaten met optionele geluidsisolatie - MCR units with optional noise insulation Spectrum per octaafband (dBA) Spectrum per octave band (dBA) 63 Hz 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz Globaal geluid sterkte dB(A) Global sound power dB(A) 102 SK 58 68 78 80 79 78 72 63 85 132 SK 58 68 78 79 79 80 73 66 86 162 SK 61 71 81 82 82 82 75 68 88 192 PK 62 71 81 84 84 82 77 72 89 232 PK 61 71 81 82 84 83 83 78 90 262 PK 61 71 81 82 83 83 84 79 90 322 PK 61 71 81 82 85 83 77 68 90 MCR Het niveau van de globale geluidssterkte is in overeenstemming met ISO-standaard 3744 en het certificeringsprogramma Eurovent. Global sound power level measured in compliance with ISO standard 3744 and under Eurovent certification programm De geluidsdruk in dB(A), berekend op 10 m afstand in een open ruimte op een weerkaatsend oppervlak, wordt alleen als richtlijn gegeven. Alleen het geluidssterktespectrum en de waarde voor de globale geluidssterkte worden gebruikt om de drukkarakteristieken ter plekke te bepalen. Sound pressure in dB(A) calculated at 10 m, in a free field on a reflecting surface, is given as a guide only. Only the sound power spectrum and the global sound power value are used in determining pressure characteristics on site. • 18 • MCR WERKINGSGEBIED OPERATING LIMITS TYPE - TYPE MCR 102 S 132 S 162 S 192 P 232 P 262 P 322 P Intredetemperatuur gekoeld water Chilled water entering temperature Minimum : (2) Maximum : +20°C Uittredetemperatuur gekoeld water (1) Leaving chilled water temperature (1) Minimum : + 5 °C Maximum : +12°C Uittredetemperatuur warm water Leaving hot water temperature Minimum : Maximum : +50°C Verschil gekoeld water intrede/uittrede Difference chilled water inlet/outlet Minimum : (3) Maximum : +8°C Maximale waterstroomsnelheid Maximum water flow rate m 3/ h 23,1 38,9 38,9 89,3 89,3 89,3 89,3 (1) : Voeg onder +5°C glycol toe aan de verwarmingsvloeistof - Below +5°C, add glycol to the heating fluid. (2) : Waarde komt overeen met minimumuittredetemperatuur van +4°C voor gekoeld water bij een gegeven stroomsnelheid Value corresponding to the minimum of +4°C chilled water leaving temperature at considered flow rate (3) : Komt overeen met de acceptabele maximumstroomsnelheid van de verdamper. - Corresponding to the evaporator acceptable maximum flow rate NEEM CONTACT MET ONS OP WANNEER DEZE WAARDEN NIET WORDEN GEHAALD OF WORDEN OVERSCHREDEN OUTSIDE THESE VALUES, PLEASE CONSULT US. MAXIMALE OMGEVINGSLUCHTTEMPERATUUR - MAXIMUM AMBIENT AIR TEMPERATURE De temperaturen worden berekend op basis van startomstandigheden bij volledige capaciteit, met twee verschillende configuraties : Temperatures are calculated according to full capacity start-up conditions, with two different configurations : " # Apparaat in werking met volledige belasting Full load operating unit MCH-apparaat tijdens werking met hogedrukafvoer MCH unit in HP offloading operation Maximale omgevingsluchttemperatuur (°C) Maxi ambient air temperature (°C) 700 TPM 700 RPM 550 TPM 550 RPM Configuratie Configuration Configuratie Configuration MCR " # " # 102 SK 38,5 51 38 51 132 SK 35 49,5 34 49 162 SK 43 53,5 43 53,5 192 PK 41 50,5 40,5 50,5 232 PK 38 47,5 37,5 47 262 PK 35 45 34 44,5 322 PK 38,5 48 38 47,5 MCR • 19 • BELGIEN, LUXEMBURG : DUITSLAND : ENGELAND, IERLAND : FRANKRIJK : NEDERLAND : OEKRAÏNE : POLEN : PORTUGAL : REPUBLIEKEN TSCJECHIË : RUSLAND : LENNOX BENELUX N.V./S.A. Tél : + 32 3 633 30 45 Fax : + 32 3 633 00 89 e-mail : [email protected] LENNOX DEUTSCHLAND GmbH Tél : + 49 69 42 09 79 0 Fax : + 49 69 42 09 79 40 e-mail : [email protected] LENNOX INDUSTRIES Ltd Tél : + 44 1604 599400 Fax : + 44 1604 594200 e-mail : [email protected] LENNOX FRANCE Tél : + 33 1 64 76 23 23 Fax : + 33 1 64 76 35 75 e-mail : [email protected] LENNOX BENELUX B.V. Tél : + 31 33 2471 800 Fax : + 31 33 2459 220 e-mail : [email protected] LENNOX DISTRIBUTION KIEV Tél : + 380 44 219 23 23 Fax : + 380 44 213 14 21 e-mail : [email protected] LENNOX POLSKA Sp. z o. o. Tél : + 48 22 832 26 61 fax : + 48 22 832 26 62 e-mail : [email protected] LENNOX PORTUGAL Lda. Tél : + 351 22 998 33 70 Fax : + 351 22 998 33 79 e-mail : [email protected] LENNOX JANKA a.s. Tél : + 420 2 510 88 111 Fax : + 420 2 579 10 393 e-mail : [email protected] LENNOX DISTRIBUTION MOSCOW Tél : + 7 095 246 07 46 Fax : + 7 502 933 29 55 e-mail : [email protected] SLOVAKIJE : LENNOX SLOVENSKO s.r.o. Tél : + 421 2 44 87 19 27 Fax : + 421 2 44 88 64 72 e-mail : [email protected] SPANJE : LENNOX REFAC S.A. Tél : + 34 915 40 18 10 Fax : + 34 915 42 84 04 e-mail : [email protected] ANDERE EUROPESELANDEN, AFRIKA, MIDDEN-OOSTEN : LENNOX DISTRIBUTION Tél : + 33 4 72 23 20 14 Fax : + 33 4 72 23 20 28 e-mail : [email protected] www.lennoxeurope.com MCR_AGU_0102-D Als gevolg van Lennox's continue streven naar kwaliteitsverbeteringen kunnen specificaties en afmetingen wijzigen zonder voorafgaande meldingen en aansprakelijkheidsstelling. Onjuiste installatie, instellingen, opstellingen, service of onderhoud kan tot schade of persoonlijk gevaar leiden. Installatie en service dient door gekwalificeerde installateurs en serviceagenten te worden uitgevoerd
advertisement
Key Features
- Capacity control
- Antifreeze protection
- Compressor sound-insulated compartments
- Compact size
- Quiet operation
- Advanced technology
- Reliability & safety
- CLIMATICâ„¢ II microprocessor
- Control & monitoring