INSTALLATION INSTRUCTIONS
AES-3 Module
The AES-3 option module adds digital input and output via RJ-45 or coax to V-
Series main panels and desktop panels. The AES-3 module cannot be fitted to early versions of the V-Series panels and the panel should be checked for compatibility before attempting to fit the AES-3 module.
The AES-3 upgrade kit contains the following items:
1 x AES-3 interface card part no. 710850Z
1 x AES-3 screening card part no. 710849Z
2 x mounting blocks part no. 240174Z
2 x panhead screw and washer assemblies part no. 280496Z
2 x panhead screws part no. 280462Z
4 x plastite screws part no. 280536Z
1 x BNC hex nut part no. 280537Z
1 x BNC locking washer part no. 280538Z
1 x Ferrite part no. 180028Z
Check that all the items are present before starting the upgrade.
Panel Compatibility
To check whether a panel can be fitted with an AES-3 module the rear of the panel should be checked. Panels that can be fitted with an AES-3 card have an additional “AES” box in the conformity label on the left of the panel rear.
The drawings Figure 1 and Figure 2 illustrate the differences.
PN 810388Z Rev. 2 1 © Clear-Com Communication Systems
V-Series AES-3 Option Clear-Com Communication Systems
Figure 1: Panel Cannot be Upgraded
PN 810388Z Rev. 2
Figure 2: Panel Can Be Upgraded
2 © Clear-Com Communication Systems
Clear-Com Communication Systems V-Series AES-3 Option
Fitting the AES-3 Option Card to Rack Mount Panels
Before fitting the AES-3 card the panel must be completely disconnected and removed from any rack or console. Place the panel on a clear workspace suitable for antistatic precautions.
Step 1
The power supply should be removed from the cradle at the back of the panel
if it has been fitted there (see Figure 3). If the power supply is not fitted in the
cradle proceed to step 2.
Figure 3: Power Supply in Cradle on Rack Mount Panel
Unlock the power connector from the panel by turning the outer ring anticlockwise then pulling the connector. Remove the power supply block by
pulling it out of the rear of the cradle (Figure 4).
Figure 4: V-Series Rack Mount Panel with PSU Removed
© Clear-Com Communication Systems 3 PN 810388Z Rev. 2
V-Series AES-3 Option Clear-Com Communication Systems
Step 2
The next step is to remove the four countersunk screws and four panhead screw and washer assemblies holding the lid on. The countersunk screws are located on the top of the lid, two of the panhead screw and washer assemblies
are located on the rear of the panel and one at each end of the panel (Figure
5). Ensure that all the screws are retained for refitting the lid.
Figure 5: Rack Mount Panel Lid Retaining Screws
PN 810388Z Rev. 2 4 © Clear-Com Communication Systems
Clear-Com Communication Systems
Step 3
V-Series AES-3 Option
Figure 6: Rack Mount Panel with Lid Removed
There are two cutouts and four screw holes in the rear metalwork which are covered from the outside by the plastic overlay. The overlay covering the cutouts and screw holes must be removed before the AES-3 card can be inserted. This should be done using a small sharp blade such as a scalpel or craft knife. Care must be taken to avoid any damage to the electronics or cables in the panel while doing this.
Pressing on the overlay will highlight the position of the holes.
Note: Ensure that no pieces of overlay are left inside the panel once the cutouts are cleared as the overlay itself is conductive and could cause damage to the panel.
Figure 7: Rack Mount Panel with Overlay Removed from Cutouts
© Clear-Com Communication Systems 5 PN 810388Z Rev. 2
V-Series AES-3 Option Clear-Com Communication Systems
Step 4
If plastic mounting blocks are not already fitted to the panel remove the two plastic mounting blocks supplied from the packaging and fit them to the panel
as shown in Figure 8 and secure them using two plastite screws as shown in
Figure 8: Rack Mount Panel with Mounting Blocks Fitted
PN 810388Z Rev. 2
Figure 9: Rack Mount Panel Mounting Block Screws
6 © Clear-Com Communication Systems
Clear-Com Communication Systems V-Series AES-3 Option
Step 5
Taking anti-static precautions remove the AES-3 option card from its packaging.
Slide the screening PCB over the front of the RJ-45 connector ensuring that the capacitors fitted to the rear of the screening PCB are at the top and press the top towards the rear of the connector so that it is held on the spring
Screening PCB
Figure 10: Screening PCB fitted to AES-3 Card
© Clear-Com Communication Systems 7 PN 810388Z Rev. 2
V-Series AES-3 Option Clear-Com Communication Systems
Step 6
Slide the AES-3 option card vertically down onto the panel main PCB ensuring that the BNC shielding clip is on the inside of the panel.
Care should be taken that the PCB connector pins on the AES-3 card are aligned with the connector on the PCB to prevent any pins being bent when the card is fitted. Do not use excessive force to fit the card as this may damage the connector if the pins are misaligned.
Ensure that the mounting holes at the rear of the AES-3 card line up with the spacers fitted to the V-Series panel main PCB . Press the top of the screening
PCB forward so that it is in contact with the back of the panel (Figure 11).
PN 810388Z Rev. 2
Figure 11: AES-3 Option card in V-Series Rack Mount Panel
8 © Clear-Com Communication Systems
Clear-Com Communication Systems V-Series AES-3 Option
Step 7
Use two panhead screws to fix the screening PCB to the chassis. Use the two panhead screw and washer assemblies to fix the AES-3 card to the spacers and the two remaining plastite screws to fix the AES-3 card to the mounting blocks.
The completed assembly is shown in Figure 12.
Figure 12: AES-3 Card with Mounting Screws in Rack Mount
Panel
© Clear-Com Communication Systems 9 PN 810388Z Rev. 2
V-Series AES-3 Option Clear-Com Communication Systems
Step 8
Screw the lid back on the panel making sure that the correct screws are used
(see Figure 5). Refit the four panhead screw and washer assemblies first and
then the four countersunk screws.
Figure 13: Completed Rack Mount Panel Upgrade with AES-3
If the power supply was originally held in the cradle replace it in the cradle and
reattach the power supply cable to the power inlet (see Figure 3).
Remount the panel in the rack or console and reconnect power and I/O cables.
PN 810388Z Rev. 2 10 © Clear-Com Communication Systems
Clear-Com Communication Systems V-Series AES-3 Option
Step 9
When the upgraded unit is connected ensure that the ferrite provided is put on the AES cable as close as possible to the connector for the BNC or RJ-45
cable that may be used (Figure 14).
Figure 14: Ferrites Fitted to BNC and RJ-45 Cables
When a panel has been fitted with an AES-3 option card the “AES” box shown
in Figure 2 should be marked with a tick using a permanent marker to record
the modification.
© Clear-Com Communication Systems 11 PN 810388Z Rev. 2
V-Series AES-3 Option Clear-Com Communication Systems
Fitting the AES-3 Option Card to Desktop Panels
Before fitting the AES-3 card the panel must be completely disconnected from any cabling. Place the panel on a clear workspace suitable for antistatic precautions.
Step 1
Note: Record whether the panel has been build for desktop use or for attachment to a wall to ensure the front panel is replaced in the correct orientation.
Remove the eight countersunk screws holding the front of the panel on. The countersunk screws are located on the ends of the panel, four on each end
Figure 15: Desktop Panel Retaining Screws
Remove and retain all the screws and and remove the front panel assembly.
The cables connecting the front panel electronics to the main PCB are long enough to allow the panel front to be removed without having to unplug any of
PN 810388Z Rev. 2 12 © Clear-Com Communication Systems
Clear-Com Communication Systems V-Series AES-3 Option
Figure 16: Interior of Desktop Panel Before Removing Cutouts
© Clear-Com Communication Systems 13 PN 810388Z Rev. 2
V-Series AES-3 Option Clear-Com Communication Systems
Step 2
There are two cutouts and two screw holes in the rear metalwork which are covered from the outside by the plastic overlay. The overlay covering the cutouts and the screw holes must be removed before the AES-3 card can be inserted. This should be done using a small sharp blade such as a scalpel or craft knife. Care must be taken to avoid any damage to the electronics or cables in the panel while doing this.
Pressing on the overlay will highlight the position of the holes.
Note: Ensure that no pieces of overlay are left inside the panel once the cutouts are cleared as the overlay itself is conductive and could cause damage to the panel.
Figure 17: Desktop Panel Rear Before Removing Cutouts
PN 810388Z Rev. 2 14 © Clear-Com Communication Systems
Clear-Com Communication Systems V-Series AES-3 Option
Figure 18: Desktop Panel Rear After Removing Cutouts
Figure 19: Desktop Panel with Cutouts Remove from Overlay
© Clear-Com Communication Systems 15 PN 810388Z Rev. 2
V-Series AES-3 Option Clear-Com Communication Systems
Step 3
Before installing the AES-3 option card remove the DSP card at the rear of the
main PCB to allow access (see Figure 20).
Figure 20: DSP Card Removed to Allow Access
Step 4
Taking anti-static precautions remove the AES-3 option card from its packaging.
Note: The mounting blocks should not be used when fitting the AES-3 to a desktop panel.
PN 810388Z Rev. 2 16 © Clear-Com Communication Systems
Clear-Com Communication Systems V-Series AES-3 Option
Step 5
Slide the screening PCB over the front of the RJ-45 connector ensuring that the capacitors fitted to the rear of the screening PCB are at the top and press the top towards the rear of the connector so that it is held on the spring
Screening PCB
Figure 21: Screening PCB fitted to AES-3 Card
© Clear-Com Communication Systems 17 PN 810388Z Rev. 2
V-Series AES-3 Option Clear-Com Communication Systems
Step 6
Insert the AES-3 option card into position over the main PCB so that the connectors line up with the cutouts and the PCB connector on the bottom of the card lines up with the socket on the main PCB. Ensure that the mounting holes at the rear of the AES-3 card line up with the spacers fitted to the V-
Series panel main PCB and press the card down so that the PCB connector pins are in the socket . Press the top of the screening PCB forward so that it is
in contact with the back of the panel (Figure 22).
Figure 22: AES-3 Option card in V-Series Desktop Panel
PN 810388Z Rev. 2 18 © Clear-Com Communication Systems
Clear-Com Communication Systems V-Series AES-3 Option
Step 7
Secure the BNC connector to the panel rear using the BNC Locking washer and hex nut.
Use the two panhead screws to fix the screening PCB to the chassis.
Figure 23: AES-3 Card with Hex Nut and Washer
© Clear-Com Communication Systems 19 PN 810388Z Rev. 2
V-Series AES-3 Option Clear-Com Communication Systems
Step 8
Use the two panhead screw and washer assemblies to fix the AES-3 card to
Note: A “stubby” or short handled screwdriver is required for this operation.
Step 9
Figure 24: AES-3 Option Card with Mounting Screws
Replace the DSP card in the slot at the rear of the motherboard ensuring that it is securely held by the clips.
Step 10
Replace the front panel assembly ensuring it is replaced in the correct orientation noted in step 1, making sure that the correct screws are used (see
Insert the microphone connector edge into position first, then lower the headset connector into place.
Note: Ensure that no cables are trapped before attempting to refit the screws.
Apply pressure to the lid to align the screw holes and fit the top and bottom screws loosely on each side before fitting the remaining screws and tightening all the screws.
PN 810388Z Rev. 2 20 © Clear-Com Communication Systems
Clear-Com Communication Systems V-Series AES-3 Option
Figure 25: Completed Desktop Panel Upgrade with AES-3
Re-site the panel and reconnect power and I/O cables.
When the upgraded unit is connected ensure that the ferrite provided is put on the AES cable as close as possible to the connector for the BNC or RJ-45
cable that may be used (Figure 26).
© Clear-Com Communication Systems 21 PN 810388Z Rev. 2
V-Series AES-3 Option Clear-Com Communication Systems
Figure 26: Ferrites Fitted to BNC and RJ-45 Cables
When a panel has been fitted with an AES-3 option card the “AES” box shown
in Figure 2 should be marked with a tick using a permanent marker to record
the modification.
PN 810388Z Rev. 2 22 © Clear-Com Communication Systems
advertisement