McGuire HP-H Dock Leveler Owner’s/User’s Manual

McGuire HP-H Dock Leveler Owner’s/User’s Manual

Below you will find brief information for Dock Leveler HP-H. The HP-H series dock leveler is designed to compensate for a maximum ± 12 in. of height difference between the loading dock and the transport vehicle bed. Its revolutionary hydraulic system efficiently controls and operates every function. To obtain maximum performance and longest possible use, a simple program of preventive maintenance is recommended.

advertisement

Assistant Bot

Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.

Dock Leveler HP-H Owner's Manual | Manualzz
HP-H
SERIES
PR SERIES
Dock Leveler
Owner’s/User’s
Owner’s Manual
Manual
MCGUIRE • Division of Systems, Inc. • W194 N11481 McCormick Drive • Germantown, WI 53022
800.643.5424 • fax: 262.257 7399 • www.docksystemsinc.com • [email protected]
Printed in U.S.A.
Copyright © 2015
Manual No. 4111-0018
May 2015
Table of Contents
Safety
Page
Recognize Safety Information...........................................................................
General Operational Safety Precautions.........................................................
Operational Safety Precautions........................................................................
Maintenance Safety Precautions......................................................................
Safety Decals......................................................................................................
Owner’s/User’s Responsibilities.......................................................................
Introduction
General Information...........................................................................................
Dock Leveler Stock Specifications...................................................................
Component Identification..................................................................................
Theory.................................................................................................................
1
1
2
4
5
6
8
8
9
9
Installation
Prepare Pit.......................................................................................................... 10
Prepare Dock Leveler....................................................................................... 11
Install Dock Leveler.......................................................................................... 12
Install Control Panel and Wiring...................................................................... 18
Put New Leveler Into Service........................................................................... 19
Operation
Operating Instructions...................................................................................... 20
Ramp Loading/Unloading Instructions........................................................... 21
End Loading/Unloading Instructions.............................................................. 22
Maintenance
Service Dock Leveler Safely............................................................................ 23
Periodic Maintenance....................................................................................... 24
Adjustments
Hydraulic Pump Schematic.............................................................................. 26
Adjust Main System Pressure.......................................................................... 27
Adjust Auto Return To Dock (ARTD) Below Dock Control........................... 28
Adjust Down Speed and Lip Extension.......................................................... 30
Electrical
Single Phase (Nema 4)...................................................................................... 32
Three Phase (Nema 4)....................................................................................... 33
Single Phase (Nema 12).................................................................................... 34
Three Phase (Nema 12)..................................................................................... 36
Control Panel Pictures...................................................................................... 36
Single Phase Control Panel Parts (Nema 12)................................................. 40
Three Phase Control Panel Parts (Nema 12).................................................. 42
Troubleshooting
Troubleshooting................................................................................................ 44
Parts
Frame and Platform........................................................................................... 48
Hydraulic Components..................................................................................... 52
Weather Seal, Rubber Style and Brush Style................................................. 54
Full Range Toeguards....................................................................................... 54
Power Pack Assembly ..................................................................................... 55
Miscellaneous
Notes................................................................................................................... 54
Customer Information....................................................................................... 57
Warranty .......................................................................................... Back Cover
SAFETY
Recognize Safety Information
General Operational Safety
Precautions
Safety-Alert Symbol
The Safety-Alert Symbol identifies NOTICE safety
messages on equipment, safety signs, in manuals,
or elsewhere. When you see this symbol, be alert
to the possibility of personal injury or death. Follow
the instructions in the safety message.
Read and understand the Owner’s/User’s manual
and become thoroughly familiar with the equipment
and its controls before operating the dock leveler.
Never operate a dock leveler while a safety device or
guard is removed or disconnected.
The use of the word DANGER signifies the
presence of an extreme hazard or unsafe practice
which will most likely result in severe injury or
death.
The use of the word WARNING signifies the
presence of a serious hazard or unsafe practice
which may result in serious injury or death.
The use of the word CAUTION signifies possible
hazard or unsafe practice which could result in
personal injury.
NOTICE
The use of the word NOTICE is to draw attention
to a procedure that needs to be followed to prevent
machine damage.
Never remove DANGER, WARNING, or CAUTION
signs or decals on the equipment unless replacing
them.
on
Z
ng
ati
e
r
e
Op
era
Op
g
tin
ne
Zo
Do not start the equipment until all unauthorized
personnel in the area have been warned and have
moved outside the operating zone.
Remove any tools or foreign objects from the
operating zone before starting.
Keep the operating zone free of obstacles that could
cause a person to trip or fall.
4111-0018 — May 2015
1
SAFETY
Operational Safety Precautions
Learn the safe way to operate this equipment. Read and understand the
manufacturer’s instructions. If you have any questions, ask your supervisor.
Stay clear of dock leveling device when transport
vehicle is entering or leaving area.
Chock/restrain all transport vehicles. Never remove
the wheel chocks until loading or unloading is
finished and transport vehicles driver has been
given permission to drive away.
Do not move or use the dock leveling device if
anyone is under or in front of it.
Do not use a broken or damaged dock leveling
device. Make sure proper service and maintenance
procedures have been performed before using.
Keep hands and feet clear of pinch points. Avoid
putting any part of your body near moving parts.
Make sure lip overlaps onto transport vehicles bed
at least 4 in. (102 mm).
Keep a safe distance from both side edges.
2
4111-0018 — May 2015
SAFETY
Do not use dock leveling device if transport vehicle
is too high or too low.
Do not overload the dock leveling device.
Do not operate any equipment while under the
influence of alcohol or drugs.
Do not leave equipment or material unattended on
dock leveling device.
4111-0018 — May 2015
3
SAFETY
Maintenance Safety Precautions
ALWAYS disconnect electrical power source and
ground wire before welding on dock leveler.
DO NOT ground welding equipment to any hydraulic
or electrical components of the dock leveler. Always
ground to the dock leveler frame.
Hydraulic and electrical power must be OFF when
servicing the equipment. For maximum protection,
use an OSHA approved locking device to lock
out all power sources. Only the person servicing
the equipment should have the key to unlock the
device.
Failure to follow these instructions may result in
damage to dock leveler and/or serious personal
injury or death.
DO NOT grind or weld if hydraulic fluid or other
flammable liquid is present on the surface to be
ground or welded
DO NOT grind or weld if uncontained hydraulic fluid
or other flammable liquid is present. Stray sparks
can ignite spills or leaks near the work area. Always
clean up the oil leaks and spills before proceeding
with grinding or welding.
Always post safety warnings and barricade the
work area at dock level and ground level to prevent
unauthorized use of the unit before maintenance is
complete.
Always keep a fire extinguisher of the proper type
nearby when grinding or welding.
Failure to follow these instructions may result in
serious personal injury or death.
ALWAYS stand clear of dock leveler lip when
working in front of the dock leveler. Failure to do this
may result in serious personal injury or death.
A maintenance prop permanently attached and
hinged to the unit with means for lock out/tag out
requirements (per OSHA 1910.147) is included
with each pit style dock leveler. In addition, it is
recommended and good safety practice to use an
additional means to support the dock platform and
lip anytime when physically working in front of or
under the dock leveler. This additional means may
include, but not limited to a boom truck, fork truck,
stabilizing bar or equivalent.
4
4111-0018 — May 2015
SAFETY
Safety Decals
5.06"
DANGER
1751-0727
CRUSH HAZARD
Maintenance prop must
support leveler behind bar.
Do not force maintenance
prop forward of bar to
support lip. Failure to
comply will result in death or
serious injury. Refer to
owner’s/user’s manual for
proper use.
2.40"
Every 90 days (quarterly) inspect all safety labels and tags to
ensure they are on the dock leveler and are easily legible. If any
are missing or require replacement, please call 1-800-643-5424
for replacements.
1751-0730 (x2)
1751-0727 Rev A
Control Box Size:
9.12"
Decal Size:
5.06 x 2.40
File Name: 1751-0727 Rev A
SAFETY INFORMATION
DANGER
3.25"
Unsupported dock leveler
ramps can lower unexpectedly.
Before allowing vehicle to leave
the dock always:
Ensure no equipment,
material or people are on
dock leveler.
Return dock leveler to its
stored position at dock level.
Failure to follow posted instructions will result in death or serious injury.
OPERATION
1. Read and follow all instructions and
warnings in owner’s/user’s manual.
2. Use of dock leveler restricted to
trained operators
3. Always chock trailer wheels or
engage truck restraint before
operating dock leveler or beginning to
load or unload.
4. Never use hands or equipment to
move ramp or lip
5. Before activating dock leveler:
Ensure trailer is backed in against
bumpers.
Remove any end loads if required.
Check trailer alignment to avoid lip
interference. If lip does not lower to
trailer bed, reposition vehicle.
6. Ensure truck bed supports extended
lip or leveler frame supports the ramp
before driving on ramp.
7. Stay clear of hinges and front and
sides of moving dock leveler.
8. N e v e r u s e d a m a g e d o r
malfunctioning dock leveler. Report
problems immediately to supervisor.
MAINTENANCE/SERVICE
1. Read and follow all instructions,
warnings and maintenance
schedules in the owner’s/user’s
manual.
2. Maintenance/Service of dock leveler
restricted to trained personnel.
3. Place barriers on the driveway and
dock floor to indicate service work is
being performed.
4. DO NOT ENTER PIT unless dock
leveler is securely supported by
maintenance prop.
5. If electrically powered turn off and use
OSHA lockout/tagout procedures.
Call 262.255.1510 for replacement placards, warning labels, or owner’s/user’s manuals.
(decal placed in same position on both sides)
Control Box Size:
Decal Size: 9.12 x 3.25
File Name: 1751-0730 Rev A
1751-0329 (x2)
DO NOT
FORK THIS SIDE
(decal placed in same position on both sides)
Control Box Size:
Decal Size: 13 x 2
File Name: 1751-0329
1751-0330 (x2)
FORK
HERE
(decal placed in same position on both sides)
Control Box Size:
Decal Size: 5.375 x 1.75
File Name: 1751-0330 REV B
! DANGER
1751-0138
CRUSH HAZARD
DO NOT REMOVE hydraulic cylinder until leveler is
safely supported by maintenance prop. Refer to
owner’s/user’s manual for proper maintenance
procedure. Failure to comply will result in death or
serious injury.
1751-0729
1.02"
8.72"
Control Box Size:
Decal Size: 4 x 2
File Name: 1751-0138 Rev A
DANGER
CRUSH HAZARD
Do not work under dock leveler unless this maintenance prop has been secured in the upright
position. Failure to comply will result in death or serious injury. See owner’s/user’s manual for proper
procedures.
1751-0729 Rev A
5.05"
Control Box Size:
Decal Size: 8.72 x 1.02
File Name: 1751-0729 Rev A
DANGER
CRUSH HAZARD
2.40"
1751-0731
Rotate prop to maintenance
position. Open the pin latch
and insert through the
maintenance prop housing.
Close the pin latch to secure
prop. Use every time dock
leveler is serviced. Failure to
comply will result in death
or serious injury.
1751-0731 Rev A
Control Box Size:
Decal Size: 5.05 x 2.40
5.92"
File Name: 1751-0731Rev
A
DANGER
2.36"
1751-0726
CRUSH HAZARD
DO NOT ENTER PIT unless dock leveler is
securely supported by maintenance prop. Place
barriers on driveway and dock floor to indicate
service work being performed. Failure to comply
will result in death or serious injury. Refer to
owner’s/user’s manual for proper maintenance
procedures.
1751-0726 Rev A
Control Box Size:
Decal Size: 5.92 x 2.36
File Name: 1751-0726 Rev A
4111-0018 — May 2015
5
OWNER’S/USER’S RESPONSIBILITIES
1. The owner/ user should recognize the inherent dangers of the interface between the loading dock and
the transportation vehicle. The owner/ user should, therefore, train and instruct all operators in the safe
operation and use of the loading dock equipment in accordance with manufacturer’s recommendations
and industry standards. Effective operator training should also focus on the owner’s/user’s company
policies and operating conditions. Maintaining, updating and re training all operators on safe working
habits and operation of the equipment, regardless of previous experience, should be done on a regular
basis and should include an understanding and familiarity with all functions of the equipment.
Owner’s/user’s shall actively maintain, update and retrain all operators on safe working habits and
operations of the equipment.
2. The manufacturer shall provide to the initial purchaser all necessary information regarding Safety
Information, Operation, Installation and Safety Precautions, Recommended Initial and Periodic
Inspections Procedures, Planned Maintenance Schedule, Product Specifications, Troubleshooting
Guide, Parts Break Down, Warranty Information, and Manufacturers Contact Information, as well as
tables to identify the grade(slope) for all variations of length or configuration of the dock leveling device
and information identifying the maximum uncontrolled drop encountered when sudden removal of
support while in the working range of the equipment.
3. It is recommended that when the transportation vehicle is positioned correctly in the dock opening and in
contact with both bumpers, there shall be a minimum of 4.00 inches (100mm) overlap of the leveling
device and the transportation vehicle at all times during the loading and unloading process.
4. The Owner/User must review all name plates, placards, decals, instructions and posted warnings and
place the same in view of the operator or maintenance personnel for whom such warnings are intended
for. Contact manufacturer for any replacements.
5. Manufacturer’s recommended periodic maintenance and inspection procedures in effect at the date of
shipment shall be followed at all times. Written documentation of maintenance, replacement parts or
damage should be retained. In the event of damage notification to the manufacturer is required.
6. Loading dock equipment that has been structurally damaged or has experienced a sudden loss of main
support while under load (such as what might occur when a transport vehicle pulls out from under the
leveling device) shall be removed from service, inspected by a manufacturer’s authorized representative,
and repaired or replaced as needed before being placed back in service.
7. Any modifications or alterations of loading dock equipment shall only be done with prior written approval
from the manufacturer and the same shall be at least as safe as the original equipment was prior to the
modification and shall also satisfy all safety requirements of the manufacturer for the particular
application of the leveling device.
8. When industrial moving devices are being used in the loading or unloading of product from the
transportation vehicle, this vehicle shall have the brakes and wheel chocks applied appropriately or all
other positive restraining device shall be fully utilized. It is recommended that transport vehicles with airride suspension systems shall have its air exhausted prior to performing loading and unloading operation
to minimize transport vehicle bed drop.
9. Loading dock safety equipment should never be used outside of its intended use, vertical working range,
or capacity. Please consult the manufacturer if you have any questions as to the use, vertical working
range or capacity of the equipment. Only properly trained and authorized personnel should operate the
equipment.
10. When selecting loading dock safety equipment, it is important to consider not only present requirements
but also future plans and any possible adverse conditions, environmental factors or usage.
6
4111-0018 — May 2015
INTRODUCTION
General Information
Dock Leveler Stock Specifications
HP/H dock levelers are available in the following sizes,
weight capacities, and options:
Width: HP/H
6 ft (1828.8 mm)
6-1/2 ft (1981.2 mm)
7 ft (2133.6 mm)
Length
6 ft (1828.8 mm)
8 ft (2438 mm)
10 ft (3048 mm)
12 ft (3658 mm)
Congratulations on your choice of a McGuire dock
leveler. This manual covers the HP/H series hydraulic
dock leveler.
Designed by McGuire. to be a marvel of simplicity and
efficiency, your dock leveler, when properly installed,
will provide many years of trouble-free performance
with an absolute minimum of maintenance. Its
revolutionary hydraulic system efficiently controls
and operates every function. To obtain maximum
performance and longest possible use, a simple
program of preventive maintenance is recommended.
Capacity (CIR*)
25,000 lb (11 340 kg)
30,000 lb (13 608 kg)
35,000 lb (15 876 kg)
40,000 lb (18 144 kg)
45,000 lb (20 412 kg)
55,000 lb (24 948 kg)
75,000 lb (34 019 kg)
100,000 lb (45 359 kg)
* CIR (Comparative Industry Rating)
Call McGuire, to discuss available voltages, phases
and options to meet your specific needs.
The HP/H series dock leveler comes equipped with
an electrical control panel, which allows pushbutton
operation of the dock leveler functions. Each
HP/H dock leveler unit and control panel has been
factory prewired and tested to ensure satisfactory
operation.
To illustrate which connections are to be made in the
field at installation, electrical drawings are included
with each order or by contacting McGuire Technical
Services.
Once again, thank you and congratulations on your
purchase of a McGuire hydraulic dock leveler.
4111-0018 — May 2015
7
INTRODUCTION
Component Identification
C
A
B
G
F
E
D
J
I
H
E
A — Lip
B — Platform
C — Lip Cylinder
D — Powerpack (Motor/Pump/Reservoir)
E — Prop Pin and Clip
F — Platform Cylinder
G — Main Frame
H — Lip Keepers (2 used)
I — Maintenance Prop
J —Toe Guard (2 used) THEORY
The HP/H dock leveler uses hydraulics and one‑button
operation for ease of use.
Platform (B) is raised by depressing and holding the
RAISE button (K). This activates an electric motor
(D) which, in turn, drives a hydraulic pump. The
hydraulic pump forces oil into the platform cylinder(s)
(F), causing the platform to rise. Releasing the RAISE
button allows the platform to lower.
8
K
4111-0018 — May 2015
INSTALLATION
Prepare Pit
A
C
10”
14”
B
C
L
D
A—Distance (Pit Width)
(Front and Rear)
B— Distance (Dock Floor-to-Pit
Floor) (All Four Corners)
C— Distance (Pit Length)
(Both Sides of Pit)
D— Distance (Pit Corner‑to‑Corner) (Top,
Bottom, and Both Sides)
Before lowering the dock leveler into the pit, the
following must be performed:
Post safety warnings and barricade the work area at
dock level and ground level to prevent unauthorized
use of the dock leveler before installation has been
completed.
Failure to follow the installation instructions can
result in damage to dock leveler, the facilities, and/
or serious personal injury or death.
Only trained installation professionals with the
proper equipment should install this product.
NOTICE
DO NOT remove the shipping bands around the
dock leveler lip until instructed to do so.
4111-0018 — May 2015
1. Remove all debris from the pit and sweep the pit
clean.
2. Check the entire dock leveler pit for proper
construction according to approved/certified pit
drawings. Make sure pit is square by making the
following measurements:
• Measure pit width distance (A) at both front and
rear of pit.
• Measure dock floor-to-pit floor distance (B) at all
four corners.
• Measure pit length distance (C) at both sides.
• Measure corner-to-corner (crisscross) distance
(D) at both sides. Take measurements at dock
floor level and at pit floor level.
If any measurement is off by more than 1/8 in. (3.18
mm), contact Systems, Inc. Technical Services before
proceeding.
9
INSTALLATION
Prepare Dock Leveler
NOTICE
A
DO NOT remove the shipping bands (B) around
the platform lip and leveler frame at this time. The
shipping bands are needed to hold the leveler
together during the installation process.
Turn to page 16 for front pick up.
1. Remove any control panel and bumpers that
may be banded to the frame of the dock leveler.
DO NOT remove the shipping bands (B) around
the platform lip and leveler frame at this time
B
A— Lifting Bracket (2 used)
B — Shipping Bands
McGuire dock levelers are designed with installation
in mind. Each unit is shipped with lifting brackets (A)
fastened to the platform side joists. A third sling may
be used to install the unit.
The dock leveler is heavy. Use a lifting device and
chains with the appropriate lifting capacity and
reach.
Always use the lifting brackets provided with the unit
whenever lowering or lifting a dock leveler into or
out of a pit.
Failure to follow these instructions may result in
damage to dock leveler and/or serious personal
injury or death.
NOTICE
DO NOT overtighten the lifting bracket hardware.
Overtightening can damage the weather seal, if
equipped.
NOTE:Overall width of platform and lifting brackets
(A) must be kept to a minimum to prevent interference
between the lifting brackets and the pit walls as the
dock leveler is lowered into the pit.
2. Make sure the mounting hardware of lifting
brackets (A) is snug. The brackets should pivot
relatively freely on the mounting cap screw. DO
NOT overtighten.
3. Attach lifting chains to lifting brackets (A) and to a
lifting device (i.e., hoist or fork truck) having the
appropriate lifting capacity and reach.
4. Remove shipping pallet, if present, before putting
the dock leveler into the pit.
NOTE: A third sling may be used to
install the unit as needed.
10
4111-0018 — May 2015
INSTALLATION
Install Dock Leveler
Shim
Stacking Methods
M
N
P
Q
D
A— Distance (Leveler Frame
Height)
B— Shim Locations (Under
Rear Vertical Supports)
C— Shim Location (Under
Maintenance Prop,Lip
keepers, Main cylinder)
D— Dock Floor
E—Rear Pit Curb Angle
F— String
4111-0018 — May 2015
G— Rear Hinge Frame Angle
H— Distance (Dock Floor-toPit Floor)
J— Distance (Top of Shim
Stack-to-Dock Floor)
K— Shim Stack
L— Dock Leveler Frame
M — Pyramid (Preferred)
N— Stepped (Acceptable)
P— Offset (Not Acceptable)
Q — Straight (Not Acceptable)
E
F
G
L
J
K
H
11
INSTALLATION
NOTE:McGuire dock levelers are designed with a
nominal 1/2 in. (12.7 mm) shimming distance to allow
for pit inconsistencies.
leveler height (A).
4. For all HP/H models, put a minimum 1/4 in. (6.6
mm) thick shim at locations (B and C).
1. Determine height of shim stack (K) for each shim
location (B) by performing the following:
NOTE: A 1/4 in. (6.6 mm) thick shim at locations (B
and C) is used only as a starting point. The final shim
stack height will be determined after dock leveler is
lowered into the pit.
a. Measure leveler frame height distance (A).
b. Measure dock floor-to-pit floor distance (H)
at each shim location (B). Write down the
dimensions obtained at each location.
c. Subtract distance (A) from distance (H) to
obtain the shim height. Repeat for each shim
location.
The dock leveler is heavy. Use chains and a lifting
device with the appropriate lifting capacity and
reach. Failure to do so may result in damage to dock
leveler and/or serious personal injury or death.
NOTICE
The minimum size of the shim that contacts the
leveler frame (i.e., the top shim of each shim stack)
must be at least 4-1/2 x 4-1/2 in. (114.3 x 114.3
mm) to support the full width of the frame rail and to
provide a shelf for a fillet weld.
Use the thickest shim stock possible for stability
and weld penetration purposes. DO NOT use
multiple layers of 1/8 in. (3.18 mm) or thinner shim
stock.
2. Using the results obtained in step 1, create the
individual shim stacks on the pit floor at locations
(B). Build each shim stack (K) using the pyramid
method (M) (preferred) or stepped method (N)
with the top shim having a minimum size of 4-1/2 x
4‑1/2 in. (114.3 x 114.3 mm) and each successive
lower shim being larger so the shims can be
welded together using a fillet weld. DO NOT use
offset method (P) or straight method (Q).
5. Using an appropriate lifting device connected to
the lifting brackets, lower dock leveler into the pit
so rear hinge frame angle (G) is tight against rear
pit curb angle (E) across full width of the leveler
frame.
6. Allow rear of dock leveler to rest on the rear shims
while keeping the front of the dock leveler level
with the dock floor.
7. For all HP/H models, add shims at front shim
locations (C) so front of dock leveler will stay
level with dock floor when leveler is resting fully
on shims.
NOTE: To assist in obtaining an accurate measurement
of distance (J), use a string (F) pulled tight across the
pit opening, directly over the shim locations.
3. Verify that each shim stack is at the correct height
by measuring distance (J) [top of shim stack (K)
to dock floor]. Distance (J) must equal the dock
12
4111-0018 — May 2015
INSTALLATION
A— Front of Dock Pit
B— Dock Leveler Frame
C— Side Pit Curb Angle
D— Gap [3/4 in. (19 mm)
Minimum]
8. With rear hinge frame angle (F) tight against rear
pit curb angle (G), perform/check the following:
• Pry between the platform and rear hinge frame
angle at locations (E) to make sure rear edge of
platform is parallel to the rear hinge frame angle
(F).
• Gap (D) must exist equally along both sides of
leveler so weather seal (if equipped) will not bind
during dock leveler operation.
4111-0018 — May 2015
E— Pry Locations
F— Rear Hinge Frame
Angle
G— Rear Pit Curb Angle
H— Flare Bevel Weld, Typical
(To Fit Spacing)
9. If gap (D) cannot be obtained equally at both sides
of leveler, grind or add material at the rear edge of
rear hinge frame angle (F) as needed.
10.Allow the dock leveler to rest fully on the shim
stacks. Check that a smooth and level transition
exists between the dock floor and the dock leveler
platform. Add or remove shims as necessary until
a smooth transition is obtained.
11.If leveler cannot be squared and/or made level as
instructed in steps 8 — 10, contact Systems, Inc.
Technical Services.
13
INSTALLATION
NOTICE
DO NOT grind or weld if hydraulic fluid or other
flammable liquid is present on the surface to be
ground or welded.
DO NOT grind or weld if uncontained hydraulic fluid
or other flammable liquid is present. Stray sparks
can ignite spills or leaks near the work area. Always
clean up the oil leaks and spills before proceeding
with grinding or welding.
Always keep a fire extinguisher of the proper type
nearby when grinding or welding.
Failure to follow these instructions may result in
serious personal injury or death.
NOTICE
DO NOT connect the dock leveler electrical wiring
and ground connections until all welding has been
completed.
DO NOT ground welding equipment to any
hydraulic or electrical components of the dock
leveler. Always ground welding equipment to the
dock leveler frame, NEVER to the platform.
Failure to follow these instructions may damage the
motor, hoist cylinder, wiring, and/or control panel.
DO NOT weld continuously along the full length
of the rear hinge frame angle. This can put
unnecessary stress on the leveler components,
causing the leveler to malfunction and shorten the
lifespan of the affected components.
12.With the rear hinge frame angle (F) tight against
the rear pit curb angle (G), weld the rear hinge
frame angle (F) to the rear pit curb angle (G)
using a 3/8 in. (9.5 mm) flare bevel skip weld
— each weld being 6 in. (152 mm) long.
Start at each end with a 6 in. (152 mm) long
weld. Space all the other welds out evenly leaving
approximately 6 in. (152 mm) space between each
weld.
13.Weld front of dock leveler frame (B) to shims
located under the keepers, then weld the shims to
the front pit curb steel.
14.With leveler welded into place, remove the shipping
bands from around lip and leveler frame.
15.Using an external lifting device (i.e., crane or fork
truck) attached to the platform lifting brackets,
slowly raise the platform. Check for binding as
platform is being raised.
NOTE:The illustration on the previous page shows a
typical weld pattern. The weld pattern will vary
slightly depending on size of dock leveler.
If the platform is raised using an external lifting device
or the hydraulic system is opened to atmosphere, air
will enter into the hydraulic system.
Whenever this happens, always cycle the leveler
at least 4 times using the leveler’s own hydraulic
power system before allowing the leveler to be put
into service. This is to make sure all air is purged
from the hydraulic cylinders. Failure to do this may
result in serious personal injury or death.
14
4111-0018 — May 2015
INSTALLATION
A— Platform Joists
B—Platform Maintenace Prop
16.If binding occurs, lower the platform. Reposition
leveler and/or add or remove shims as necessary.
Slowly raise platform again. If platform still binds,
contact Systems, Inc. Technical Services for
further instructions.
C—Prop Pin and Clip
Two people are required to engage the
maintenance prop: one person to operate the
lifting device, the other person to engage the
maintenance prop.
17.All HP/H models:
a. Install shims under maintenance prop (B)
where prop attaches to leveler frame. Make
sure prop is solidly shimmed.
b. Using the appropriate lifting device, attached
to the platform lifting lugs, slowly raise the
dock to the fully open position.
c. Raise maintenance prop (B) to the service
(upright) position and lock prop in this position
using an OSHA approved locking device.
(Supplied by others)
DO NOT use the maintenance prop to support the
raised platform until the maintenance prop has
been properly shimmed and welded. The shims
must be welded to each other, the leveler frame,
and to the front pit curb steel. Failure to do this
may result in serious personal injury or death.
d. Proceed to step 18.
4111-0018 — May 2015
15
INSTALLATION
18.All model levelers: Install shims at locations (B)
(C) (Ref.page 12) using the pyramid or stepped
shimming method. Both platform cylinder trunnions
must be solidly shimmed the entire length of the
trunnion. Make sure the trunnions are level from
side-to-side as well as from front-to-back.
Make sure the platform is properly supported in the
raised position before entering the pit to finish weld
the shims. Failure to do this may result in serious
personal injury or death.
19.Finish weld all shims using a fillet weld.
•
Weld all shims within each shim stack to each
other, then weld the shim stack to the leveler
frame.
•
Weld the front leveler frame shim stacks to
the front pit curb steel.
20.When all welding has been completed, paint all the
welds and shims.
NOTE:
To pick up unit from the front, move forks closer
together and slide over the frame and under the cross
member. It may be necessary to unband the unit to
gain access to the front, by lifting the lip up then sliding
the forks under the cross member. (Ref: page 11)
Shim
Stacking Methods
Front Pick Up
M
N
P
Q
Rear Pick Up
* For left/right orientation of dock leveler, see inside back cover of
this manual.
16
4111-0018 — May 2015
INSTALLATION
Install Control Panel and Wiring
A
The electrical power must be OFF prior to electrical
installation. For maximum protection, use an OSHA
approved locking device to lock out all power
sources. Only the person installing the equipment
should have the key to unlock the power source.
Failure to follow these instructions may result in
serious personal injury or death.
B
C
DO NOT make any final electrical connections until
all welding has been completed. Failure to do this
may result in serious personal injury or death.
All electrical work — including the installation of
the disconnect panel, control panel, and final
connections to the pit junction box — must be
performed by a certified electrician and conform to
all local and applicable national codes.
When drilling access hole in the control box, DO
NOT penetrate too deep, components may be
damaged.
DO NOT turn control upside down to drill any
access holes. To prevent damaged to electrical
components from debris cover components prior to
drilling
Seal all conduit entrances to prevent moisture from
entering the control box.
DO NOT use compressed air to clean control box.
Recommended to vacuum debris from inside.
4111-0018 — May 2015
A— Disconnect Panel (provided by others)
B— Control Panel
C— Distance, 48 in. (14 630 mm),
minimum.
1. Mount the pushbutton control panel (B) so bottom
of control panel-to-dock floor distance (C) is a
minimum 48 in. (1219.2 mm).
2. Install electrical disconnect panel (A) if not already
installed.
3. Install and connect the control wiring.
4. Connect the dock leveler power cable to the field
wires in the pit junction box. Refer to the electrical
drawings supplied with the dock leveler.
5. After all electrical connections in the pit have been
made, disengage the maintenance prop and
lower the platform using the external lifting device
connected to the platform lifting brackets.
17
INSTALLATION
Placard Installation Instructions
• Owner is responsible for the installation and placement of product placards.
• Make sure placard is in plain view of dock leveler operations.
• Suggested placement of placard is near control box attached to electrical
conduit by using nylon tie. If there is no control box present, mount placard
on wall to the immediate left of leveler at eye level.
Control Box
Placard
Nylon Tie
(Placard placement
shown as reference
only.)
Conduit
18
4111-0018 — May 2015
INSTALLATION
Put New Dock Leveler Into Service
1. Disconnect the external lifting device and chains
from the lifting brackets.
2. Check that the leveler is flush with the dock floor
and that the platform lip contacts both lip keepers
evenly.
If an excessive transition exists between the
dock floor and leveler and/or lip does not contact
both lip keepers evenly, contact Systems, Inc.
Technical Services for further instructions.
3. Install the dock bumpers as required.
4. Turn the main electrical power ON.
Always stand clear of platform lip when working in
front of the dock leveler. Serious personal injury or
death may result.
5. Raise the leveler platform fully by depressing and
holding the RAISE button.
NOTE: The platform of a properly operating dock
leveler will automatically stop rising when it reaches
its full raised height, at which point, the lip extends.
(If the lip does not extend or extend fully, see
Platform Rises to Full Height, But Lip Does Not
Fully Extend in the Troubleshooting section.)
6. Release the RAISE button to lower the platform. As
long as there is no transport vehicle present at the
dock, the platform will lower to the full below-dock
position with the lip extended.
NOTE:
If a transport vehicle is present, the
platform will lower until the lip rests on the
transport vehicle bed. (See Operating Instructions
in Operation section.)
7. When the platform lowers to the full below-dock
position, depress and hold the RAISE button until
the lip retracts and platform rises just enough to
have the lip clear the lip keepers, then release
the RAISE button to allow the platform to lower to
the cross‑traffic (stored) position (lip engages lip
keepers).
NOTE: For dock levelers equipped with Auto
Return To Dock (ARTD), the platform will
automatically return to the cross-traffic position
if the ARTD is in NORMAL mode. When the
platform is about 1.00 inch from the full below-dock
position, the platform will automatically rise to the
cross-traffic position.(See below dock servicing
and end loading for additional instructions)
8. Perform steps 5 – 7 at least four times to purge
any air that may be in the hydraulic system and to
Unless the dock leveler is equipped with a tethered
remote, two people are required to engage the
maintenance prop: one person to operate the unit,
the other person to engage the maintenance prop.
ensure proper operation.
9. Raise the platform fully. Hold the platform at this
position using the RAISE button and move the
maintenance prop to the service (upright) position.
Release the RAISE button to allow the platform to
lower until it is resting on the maintenance prop.
10. With the maintenance prop supporting the
platform, remove the lifting brackets on both sides
of the unit.
11. Depress and hold the RAISE button until the
maintenance prop drops to its stored position.
Release the RAISE button and allow the platform
to lower fully.
12. Perform step 7 if not equipped with ARTD.
4111-0018 — May 2015
19
OPERATION
Operating Instructions
Stay clear of dock leveler when transport vehicle is
entering or leaving dock area.
12 in. (305 mm)
DO NOT move or use the dock leveler if anyone is
under or in front of leveler.
12 in. (305 mm)
Keep hands and feet clear of pinch points. Avoid
putting any part of your body near moving parts.
Failure to follow these instructions may result in
severe personal injury or death.
Only trained personnel should operate the dock
leveler.
The HP/H hydraulic dock leveler is designed to
compensate for a maximum ± 12 in.* (305 mm) of
height difference between the loading dock and the
transport vehicle bed. DO NOT use the dock leveler
if the transport vehicle bed is more than 12 in. (305
mm) higher or lower than the dock floor.
*service height may vary with design specifications
DO NOT overload the dock leveler.
DO NOT use a broken or damaged dock leveler.
Make sure proper service and maintenance
procedures have been performed on leveler before
using.
Transport vehicle wheels must be chocked unless
the transport vehicle restraint is used. Never
remove the wheel chocks until loading/unloading is
finished and transport vehicle driver has been given
permission to leave.
DO NOT operate any equipment while under the
influence of alcohol or drugs.
DO NOT leave equipment or material unattended on
the dock leveler.
Failure to follow these instructions may result in
personal injury and/or damage to equipment.
Make sure platform lip rests on the transport vehicle
bed with at least 4 in. (102 mm) of overlap.
The dock leveler operating instructions are
divided into the two methods of loading and
unloading:
Maintain a safe distance from side edges of leveler
during the loading/unloading process.
•For ramp loading and unloading, see Ramp
Loading/Unloading Instructions on page 21.
Failure to follow these instructions may result in
serious personal injury or death.
•For end loading and unloading, see End
Loading/Unloading Instructions on page 22.
20
4111-0018 — May 2015
OPERATION
Operating Instructions—Continued
Ramp Loading/Unloading Instructions
NOTE:
If end unloading is required, see End
Loading/Unloading Instructions on page 21.
For ramp loading or unloading, the HP/H dock
leveler can be operated by using the RAISE button
on the control panel.
5. Proceed with loading or unloading the transport
vehicle.
1. Check to make sure transport vehicle is positioned
squarely against dock bumpers.
6. if end loading is necessary, see End Loading/
2. Instruct driver to remain at the dock until the
loading or unloading process has been completed.
3. Chock the transport vehicle wheels or use the A
transport vehicle restraint if available.
C
B
A—RAISE Button
B—ARTD Switch
C-LIP OUT
A
A—RAISE Button
Unloading instructions page 22.
4. Extend the platform lip onto transport vehicle as
follows:
a. Raise the platform by depressing and holding
RAISE button .
b. Hold the RAISE button until the lip is fully
extended, then release the RAISE button. The
platform will lower until the lip is resting on the
transport vehicle bed.
c. Make sure that the lip is fully extended and
supported on the transport vehicle along the
entire width of the platform with at least 4
in. (102 mm) of lip overlapping the transport
vehicle bed.
4111-0018 — May 2015
7. When loading or unloading is finished, raise the
platform by depressing and holding RAISE button
(A)
Hold the RAISE button until the lip folds enough
to clear the transport vehicle bed, then release the
RAISE button. The lip will fold and the platform will
return to the cross‑traffic position.
8. Remove chocks from transport vehicle wheels or
release the transport vehicle restraint if used.
9. Indicate to driver that transport vehicle may leave
the dock.
21
OPERATION
Operating Instructions—Continued
End Loading/Unloading Instructions
NOTE: If ramp loading is required, see Ramp
Loading/Unloading Instructions on page 19.
B
C
End loading or unloading can be done with the
A
dock at the cross-traffic position or below‑dock
position, depending on the height of the transport
vehicle bed.
1. Check to make sure transport vehicle is positioned
squarely against dock bumpers.
2. Instruct driver to remain at the dock until the
loading or unloading process has been completed.
3. Chock the transport vehicle wheels or use the
transport vehicle restraint if available.
A—ARTD Switch
6. Turn the ARTD switch (A) on the control panel to
the BELOW DOCK position, if equipped.
7. Depress the Raise button (B) to the platform just
enough to clear the lip keepers.
8. When the platform lip clears the lip keepers,
depress the Lip-Out button (C) just long enough
to clear the lip keepers. Release Lip-Out button.
The platform will drift down to the full below-dock
position.
9. Proceed with loading or unloading.
End Loading/Unloading — Platform at Cross-Traffic Position.
4. If transport vehicle bed is at or above dock floor
level, leave leveler at the cross-traffic position and
proceed with loading or unloading.
NOTE: When end unloading is finished and
access to the rest of the transport vehicle is still
required, the platform lip will need to be extended.
See Ramp Loading/Unloading Instructions on
page 19 for further instructions.
10. When the loading or unloading is finished, return
the dock leveler platform to the cross‑traffic (stored)
position by performing one of the following:
• Turn the ARTD switch (A) to the NORMAL
position, if equipped. The platform will
automatically rise to the cross-traffic position.
End Loading/Unloading — Platform at Below-Dock Position.
5. If transport vehicle bed is below the dock floor
level, and the dock is equipped with the optional
lip-out button, perform steps 6 –12.
OR
• Depress the Raise button (B) until the lip clears
the lip keepers. Release Raise button, leveler
will return to the stored or cross traffic position.
11. Remove chocks from transport vehicle wheels or
release the transport vehicle restraint if used.
Whenever end loading or unloading with the
platform in the below-dock position, make sure
the ARTD switch is in the OFF position. DO NOT
turn the ARTD switch to the ON position until end
loading or unloading is finished.
22
12. Indicate to the driver that the transport vehicle
may leave the dock.
4111-0018 — May 2015
MAINTENANCE
Service Dock Leveler Safely
Side View
D
B
A
B
A— Tagout Device
B— Lockout Device
B —Maintenance
Prop
C — Prop Pin
and Clip
D — Header Plate Note: Lockout & Tagout Devices are not supplied with leveler. They are to be supplied by others.
When service under the dock leveler is required,
always lock all electrical disconnects in the OFF
position after raising the platform and engaging the
maintenance prop. Failure to do this may result in
serious personal injury or death.
Always stand clear of the dock leveler lip when
working in front of the dock leveler.
The maintenance prop MUST be in the service
position when working under the dock leveler.
For maximum protection, use an OSHA approved
locking device to lock the maintenance prop in
the service position. Only the person servicing
the equipment should have the key to unlock the
maintenance prop.
Unless the dock leveler is equipped with a tethered
remote, two people are required to engage the
maintenance prop: one person to operate the unit,
the other person to engage the maintenance prop.
Failure to follow these instructions may result in
serious personal injury or death.
4111-0018 — May 2015
Always post safety warnings and barricade the
work area at dock level and ground level to prevent
unauthorized use of the dock leveler before
maintenance is complete. Failure to do this may
result in serious personal injury or death.
Whenever maintenance is to be performed under
the dock leveler platform, support the platform with
maintenance prop (B). Position the maintenance prop
behind front header plate (D) while staying clear of the
lip. Lock the maintenance prop in the service (upright)
position using an OSHA approved lockout device* (B)
and tagout device* (A).
Whenever servicing the dock leveler, lock the electrical
power disconnect in the OFF position. Use only an
OSHA approved lockout device* (B) and tagout device
(A).
Only the person servicing the equipment should have
the capability to remove the lockout devices. The
tagout devices* must inform that repairs are in process
and clearly state who is responsible for the lockout
condition.
* Refer to OSHA regulation 1910.146.
* Refer to OSHA regulation 1910.147.
23
MAINTENANCE
Periodic Maintenance
A
C
F
D
B
A— Lip Hinge Area
B— Power Unit and Reservoir
E
C— Platform Hinge Area
E— Platform Cylinder Pins
D— Platform Cylinder Trunnion F— Lip Cylinder Pins
Before performing any maintenance under the
dock leveler, lock the electrical power source in
OFF position and lock the maintenance prop in the
service position using an approved locking device.
(See Service Dock Leveler Safely in this section.)
Failure to follow these instructions may result in
serious personal injury or death.
NOTICE
Use of fluids that do not have equivalent
specifications to those in the following list will result
in abnormal operation of the dock leveler and
voiding of warranty.
24
To ensure normal operation of the dock leveler,
use only aircraft hydraulic fluid designed to meet
or exceed military specification MIL-H-5606G. It is
recommended that the following hydraulic fluids be
used:
•ULTRA-VIS-HVI-15
• Aero Shell Fluid 4 or Fluid 41
• Mobile Aero HFA Mil-HS606A or Aero HF
• Texaco Aircraft Hydraulic Oil 15 or 5606
• Exxon Univis J13
These fluid brands can be mixed together. Mixing
with fluids that do not meet or exceed MIL-H-5606G
may damage the equipment and WILL void warranty.
Use of hydraulic fluids with equivalent specifications
to those listed here are acceptable.
4111-0018 — May 2015
MAINTENANCE
Regular maintenance must be performed on a weekly
and quarterly schedule. Follow all safety precautions
P
N
Q
Weekly Maintenance
• Operate the dock leveler through the complete
operating cycle to maintain lubrication.
NOTE: To thoroughly inspect the platform hinge area,
put the platform in the full below‑dock­­­­­­­­­­­­­­­­­­­­­­ position.
• Inspect the platform hinge and the lip hinge areas.
The hinge areas must be kept free of dirt and
debris. Build-up of foreign material in the hinge
areas will cause abnormal operation.
M
M -- Reservoir
P - Breather Cap
N- 3 in. (76.5mm)
From Top of Reservoir
Q - Fluid Level
Quarterly Maintenance
NOTICE
Failure to properly lubricate the dock leveler will
cause abnormal operation of the leveler.
• Lubricate the following areas with light weight
machine oil:
(A)— Lip hinge area unless equipped with grease
fittings (apply oil to the top of the entire length
of lip hinge when platform is at the full belowdock position and lip is folded)
(C)— Platform hinge area (apply oil to top of all
platform hinges when platform is at the full
below-dock position)
(E)— Platform cylinder-to-platform frame pin
(F)— Lip cylinder-to-platform frame pin
• Lubricate the following areas with white lithium
grease:
NOTE:Apply grease to lip hinge grease fittings if
equipped.
NOTICE
A low fluid level or the use of hydraulic fluids not
equivalent to the fluid types recommended, will
cause abnormal operation of the leveler and WILL
void warranty.
A maintenance prop permanently attached and
hinged to the unit with means for lock out/tag out
requirements (per OSHA 1910.147) is included
with each pit style dock leveler. In addition, it is
recommended and good safety practice to use an
additional means to support the dock platform and
lip anytime when physically working in front of or
under the dock leveler. This additional means may
include, but not limited to a boom truck, fork truck,
stabilizing bar or equivalent.
• Check reservoir fluid level (Q)(see note 3):
Put the dock leveler platform at the full above‑dock
position and the lip extended.
1. Turn OFF all electrical power to the leveler.
2. Measure fluid level. The fluid level should be
approximately 3 in. (76.5 mm) (N) from top
of reservoir (M) with platform raised on the
maintenance prop.
3. Add hydraulic fluid if necessary. Use only
recommended fluid. See page 24.
4. Turn ON electrical power to the leveler.
5. Return the platform to the cross-traffic position.
4111-0018 — May 2015
25
ADJUSTMENTS
HYDRAULIC PUMP SCHEMATIC
26
4111-0018 — May 2015
ADJUSTMENTS
Adjust Main Pressure Relief
When service under the dock leveler is required,
always lock all electrical disconnects in the OFF
position after raising the platform and engaging the
maintenance prop. Failure to do this may result in
serious personal injury or death.
Always post safety warnings and barricade the
work area at dock level and ground level to prevent
unauthorized use of the dock leveler before
maintenance is complete. Failure to do this may
result in serious personal injury or death.
Always stand clear of the dock leveler lip when
working in front of the dock leveler.
The maintenance prop MUST be in the service
position when working under the dock leveler.
For maximum protection, use an OSHA approved
locking device to lock the maintenance prop in
the service position. Only the person servicing
the equipment should have the key to unlock the
maintenance prop.
Unless the dock leveler is equipped with a tethered
remote, two people are required to engage the
maintenance prop: one person to operate the unit,
the other person to engage the maintenance prop.
Failure to follow these instructions may result in
serious personal injury or death.
NOTE:The main pressure relief may need to be
increased if the platform does not rise or rises
slowly and the system operates in pressure
relief mode. See Troubleshooting section.
The main pressure relief may need to be
decreased if the pump motor loads down
when platform reaches the full raised position.
See Troubleshooting section.
G
F
A
E
B
C
D
A— Shuttle Valve, Ramp
Speed, Lowering
B— Lip Check Relief
C—System P.O. Check
A/E MAIN ADJUSTMENT VALVES
D—Reservoir
E—Sequence Valve, Lip
Extension
F—Main System Relief Valve
G—Lip Float Valve
To adjust the main pressure relief:
1. Raise the platform fully and engage the maintenance
prop in the service position.
2. Turn OFF all electrical power to the dock leveler.
Attach safety lockout and tagout devices.
3. Loose nut on valve (F)
4. Adjust hex adjusting screw (F) in small 1/4 turn
increments as follows:
• Turn clockwise to increase pressure relief.
• Turn counterclockwise to decrease pressure
relief.
5. Tighten the jam nut.
6. Turn ON electrical power to the dock leveler.
7. Disengage the maintenance prop.
8. Check leveler operation.
9. Repeat steps 1– 8 as necessary.
4111-0018 — May 2015
27
ADJUSTMENTS
Adjust Auto Return To Dock (ARTD)
C
When service under the dock leveler is required,
always lock all electrical disconnects in the OFF
position after raising the platform and engaging the
maintenance prop. Failure to do this may result in
serious personal injury or death.
B
A
D
A— ARTD ACTIVATE
B— ARTD DE-ACTIVATE
C— ARTD LIMIT SWITCH
D— ARTD SWITCH ARM
HP/H levelers are equipped with the optional Auto
Return To Dock (ARTD) if leveler not interlocked with
a transport vehicle restraint.
The ARTD allows the platform to automatically return
to the cross-traffic (stored) position after the transport
vehicle departs.
Adjust the ARTD as Follows:
NOTE: Placement of (A, B and C) are typical factory
settings. ATRD is set to engage approximately
one(1) inch before the front header hits the
header stops.
1. Raise platform fully and engage the maintenance
prop in the service position.
2. Turn OFF all electrical power to the dock leveler.
Attach safety lockout and tagout devices. (Supplied
by others)
3. Loosen nuts (A). Slide bolt up to engage ARTD
higher below dock or slide down to engage ARTD
lower below dock. Tighten nuts.
Always post safety warnings and barricade the
work area at dock level and ground level to prevent
unauthorized use of the dock leveler before
maintenance is complete. Failure to do this may
result in serious personal injury or death.
Always stand clear of the dock leveler lip when
working in front of the dock leveler.
The maintenance prop MUST be in the service
position when working under the dock leveler.
For maximum protection, use an OSHA approved
locking device to lock the maintenance prop in
the service position. Only the person servicing
the equipment should have the key to unlock the
maintenance prop.
Unless the dock leveler is equipped with a tethered
remote, two people are required to engage the
maintenance prop: one person to operate the unit,
the other person to engage the maintenance prop.
Failure to follow these instructions may result in
serious personal injury or death.
NOTE: The unit must raise enough to allow the lip to
fully retract to have the lip rest in to the lip keepers.
NOTE: The ARTD Switch arm (D) must be between
both (A) and (B) to work properly.
4. Turn power back on and run the unit through a full
cycle and repeat if necessary.
5. Loosen nut (B) and slide bolt up to shut ARTD
higher above dock or slide the bolt down to shut
off the ARTD less above dock.
28
4111-0018 — May 2015
ADJUSTMENTS
Full Below-Dock Position
The Below Dock End Load Switch (E), controls the
lip when end loading below dock. To activate turn the
selector switch (F) to BELOW DOCK position.
This will DE-ACTIVATE the Auto Return to Dock feature.
Depress and hold the RAISE button until the platform is
fully open. The lip will extend until the switch opens up
and stops the pump.
D
A
B
The lip will be extended only 2 - 3 inches to stay with in
the bumper spacing.
The platform will float to the full below dock position and
the transport vehicle and be loaded/unloaded.
In the full below dock position the switch arm (D) will
be activated by the front bolt (A) and trapped under
the back bolt (B). The switch will active approximately
1 inch before the front header is fully below dock.
When complete, turn the Selector Switch(F) back to the
NORMAL position and the platform will start to Auto
Recycle to the cross traffic position.
As the platform starts to recycle the lip will pull in
first and then the platform will start to raise. Once the
platform is high enough to have the lip clear the lip
keepers the back bolt (B) will de-activate the switch
and turn off the pump and the platform will float down
to rest in the lip keepers in the cross traffic position.
NOTE:
When servicing transport vehicles that are lower
than dock height it is recommended the BELOW
DOCK selector switch (F) be in the BELOW DOCK
mode AFTER the lip is in the bed of the transport
vehicle to prevent the Auto Return feature to activate
inadvertently.
Below Dock End Load Switch
Whenever end loading or unloading with the platform
in the below-dock position, make sure the ARTD
switch is in the BELOW DOCK position. DO NOT turn
the ARTD switch to the NORMAL position until end
loading or unloading is finished.
E
ARTD Switch Parts:
112-253 Limit Switch
112-176 Lever Arm
F
4111-0018 — May 2015
Below Dock Parts
112-356 Limit Switch
112-015 Actuator Rod Holder
521-264 Rod
29
ADJUSTMENTS
McGuire Hydraulic Pump Adjustments
30
4111-0018 — May 2015
ADJUSTMENTS
ELECTRICAL OVERVIEW
Motor: 1.25HP TENV, 3, No.56 frame, 15 minute duty cycle
Return Switch: Maintain-contact type oil-type enclosure, spring-arm actuation with adjustable
tripper arrangement.
Lip Control Switch: Momentary contact, oil-tight enclosure. Actuated by lip cylinder.
Fluid Content: ULTRA-VIS-HVI-15
Replacement hydraulic Fluid: We strongly recommend using the MIL-5606 or equivalent.
Mixing any other fluid with the MIL-5606 or equivalent will cause the fluid to break down!
Tank Capacity
25K-75K Levelers (single main cylinders)...................................................................4 quarts
100K (any dual main cylinder).....................................................................................5 quarts
MOTOR ELECTRICAL SPECIFICATIONS
Motor
Elect. Service
Voltage
RPM
HZ
Phase
FLA
Req.
115/120
3450
60
1
14.4
30*
208
3450
60
1
7.1
20
220/240
3450
60
1
7.2
20
208
3450
60
3
3.6
10
220/240
3450
60
3
3.7
10
440/480
3480
60
3
1.8
10
575
3450
60
3
1.7
10
120/208/1hp
240/1hp
220/240/3hp
460/3hp
575/3hp
0-25
#10
#12
#12
#12
#12
25-45
#8
#12
#12
#12
#12
45-75
#6
#8
#10
#10
#10
75-120
#6
#8
#10
#10
#10
120-150
#4
#6
#8
#8
#8
150-220
NR
NR
NR
NR
NR
GUIDE TO WIRE SIZE
Length of Run
CAUTION: Sufficient voltage must reach the Leveler Control box to operate the 1.25HP motor.
Voltage drop caused by long wire runs or undersized wire increase the AMP draw and will cause
the breaker to trip and/or more serious damage to occur. Therefore, it is important for installation
to be done to meet all codes and done by a licensed electrician.
IMPORTANT NOTE: The values given are intended to be ONLY a guide. Be sure to check all
electrical code, local and national before installation. This chart indicates the length of branch
circuit having a 2% voltage drop at full load amps(FLA) current, at start up, in feet.
VALUES are for THIN copper wire only.
4111-0018 — May 2015
31
ELECTRICAL 1 PHASE
32
4111-0018 — May 2015
ELECTRICAL 3 PHASE
4111-0018 — May 2015
33
ELECTRICAL 1 PHASE
34
4111-0018 — May 2015
ELECTRICAL 1 PHASE
4111-0018 — May 2015
35
ELECTRICAL 3 PHASE
208 V | 3.8A |
36
4111-0018 — May 2015
ELECTRICAL 3 PHASE
4111-0018 — May 2015
37
CONTROL PANEL
3.50
6.50
4.50
8.30
6.00
10.75 Hole Centers
10.25
6.30
38
4111-0018 — May 2015
CONTROL PANEL
Typical 3PH panel layout (Nema 12)
* Provide dock leveler serial number, voltage, phase, and options when calling or faxing controller orders.
4111-0018 — May 2015
39
CONTROL BOX PARTS SINGLE PHASE
40
4111-0018 — May 2015
CONTROL BOX PARTS SINGLE PHASE
4111-0018 — May 2015
41
CONTROL BOX PARTS THREE PHASE
42
4111-0018 — May 2015
CONTROL BOX PARTS THREE PHASE
4111-0018 — May 2015
43
TROUBLESHOOTING
Troubleshooting
When service under the dock leveler is required,
always lock all electrical disconnects in the OFF
position after raising the platform and engaging the
maintenance prop. Failure to do this may result in
serious personal injury or death.
Always post safety warnings and barricade the
work area at dock level and ground level to prevent
unauthorized use of the dock leveler before
maintenance is complete. Failure to do this may
result in serious personal injury or death.
Always stand clear of the dock leveler lip when
working in front of the dock leveler.
The maintenance prop MUST be in the service
position when working under the dock leveler.
For maximum protection, use an OSHA approved
locking device to lock the maintenance prop in
the service position. Only the person servicing
the equipment should have the key to unlock the
maintenance prop.
Unless the dock leveler is equipped with a tethered
remote, two people are required to engage the
maintenance prop: one person to operate the unit,
the other person to engage the maintenance prop.
Failure to follow these instructions may result in
serious personal injury or death.
Before performing the detailed troubleshooting procedures, check the following items first:
• Check all fuses inside the control panel(s). Replace
any blown fuse(s) with a fuse of equal specification.
• Make sure to pull the fuses out of the circuit to test.
• Make sure the correct voltages are present at the
proper locations inside the control panel(s).
Symptom
Possible Cause
Solution
Platform does not rise.
Motor does not energize.
Motor overload device
tripped or fuse blown.
Reset overload relay (three-phase) or replace fuse(s)
(single-phase). Determine cause of overload.
NOTE: When replacing fuse(s), the new fuse must
have the same specification as the old fuse.
Motor starter (three-phase) Check voltage at starter or relay coil.
or motor relay (single‑phase)
not energizing.
• If voltage is present and starter or relay does not
energize, replace starter or relay.
• If voltage is not present, check all components in
series with the starter or relay coil.
44
4111-0018 — May 2015
TROUBLESHOOTING
Symptom
Three-phase units only:
Platform does not rise.
Motor hums, but does
not run.
Possible Cause
Solution
No voltage is present on
one line.
Check for blown fuses at branch circuit disconnect.
Replace fuse. Determine cause of blown fuse.
NOTE: A motor that is
Check motor starter as follows:
missing voltage on one line 1. Disconnect wires at load side of starter.
is said to be single-phased. 2. Energize the starter.
3. Measure line-to-line voltage at line side of starter.
4. Measure line-to-line voltage at load side of starter.
5. Line-side and load-side voltages should be
approximately the same. Replace starter if
voltage values are considerably different from
one another.
Check all wiring to motor for high resistance or no
connection.
Three-phase units only:
Platform does not rise.
Motor runs in reverse
Phase reversed.
Reverse any two legs at the branch circuit disconnect.
Single-phase units only:
Platform does not rise.
Motor energizes, but
does not run.
Line voltage too low.
Check wiring to motor for high resistance. Check for
loose or corroded connections. Check if gauge of
wires to motor are of correct size and specification for
load requirement. Replace if necessary.
Dock leveler equipped
with ARTD: Platform
does not automatically
return to the cross-traffic
position or operates
abnormally.
Defective motor centrifugal
switch.
Replace motor.
Defective motor capacitor.
Replace motor.
The auto return limit switch Adjust the bolts as needed. See Adjust Auto Return
not activating correctly.
To Dock (ARTD) in the Adjustment section.
Defective limit switch.
Replace switch.
Broken wire. Loose or
Repair or replace wires and connections as necessary.
corroded wire connections.
4111-0018 — May 2015
45
TROUBLESHOOTING
Symptom
Platform does not
rise. Pump operates in
pressure relief mode.
Possible Cause
Solution
Heavy object(s) on platform. Remove object(s) from platform.
NOTE:For safety reasons, the dock leveler is
designed to lift only the platform’s own weight. The
motor will continue to run which will result in melting
the reservoir.
Dock leveler binds.
Check for visible obstructions that could cause
binding. Remove obstructions. If no obstructions
found, call Systems, Inc. Technical Services. See
inside back cover for phone number and address.
Pressure relief set too low.
Increase pressure relief. See Adjust Main Pressure
Relief in the Adjustment section.
NOTE: The pressure relief valve must not be set at
a level that causes the motor operating current to
exceed the full load amp value* at any time, including
when operating in pressure relief.
*The full load amp value can be found on the inside cover of the
control panel.
Platform rises slowly.
Low hydraulic fluid.
Add fluid as needed. See Periodic Maintenance in the
Maintenance section.
Contaminated hydraulic
system.
Clean and inspect valves. Flush contaminated oil
from hydraulic system. Fill system with new oil. See
Periodic Maintenance in the Maintenance section.
Damaged or restricted
hydraulic hose(s).
Replace damaged hose(s). Remove restriction.
Pressure relief set too low.
Increase pressure relief. See Adjust Main Pressure
Relief in the Adjustment section.
NOTE: The pressure relief valve must not be set at
a level that causes the motor operating current to
exceed the full load amp value* at any time, including
when operating in pressure relief.
*The full load amp value can be found on the inside cover of the
control panel.
Pump motor loads down
when platform reaches
the full raised position.
Pressure relief set too high. Decrease pressure relief. See Adjust Main Pressure
Relief in the Adjustment section.
NOTE: The pressure relief valve must not be set at
a level that causes the motor operating current to
exceed the full load amp value* at any time, including
when operating in pressure relief.
*The full load amp value can be found on the inside cover of the
control panel.
46
4111-0018 — May 2015
TROUBLESHOOTING
Symptom
Possible Cause
Solution
Platform does not rise to
full height.
Low hydraulic fluid.
Add fluid as needed. See Periodic Maintenance in the
Maintenance section.
Platform DOES rise to
full height, but lip DOES
NOT extend or extend
fully.
Low hydraulic fluid.
Add fluid as needed. See Periodic Maintenance in the
Maintenance section.
The BELOW DOCK switch
is in the BELOW DOCK
position
Turn the switch to the NORMAL position.
Lip does not extend.
Sequence valve out of
adjustment
Adjust the sequence valve out( counter clock wise) to
get the lip to swing out sooner.
Lip extends almost
immediately when
the RAISE button is
depressed.
Sequence valve out of
adjustment
Adjust the sequence value in( clock wise) to keep the
lip from swinging out too soon.
4111-0018 — May 2015
47
PARTS
Frame - Platform - Lip
A
B
D
F
G
E
H
C
L
J
K
48
4111-0018 — May 2015
PARTS
Lip and Platform
ITEM
LIPS
QTY
6.0 FOOT
1
A
1
1
25K
30K
35K
40/45K
55K
75K
100K
16
0595-5045
0595-5054
0595-5063
0595-5072
0595-5081
0595-5090
0595-5099
18
0595-5046
0595-5055
0595-5064
0595-5073
0595-5082
0595-5091
0595-5100
20
0595-5047
0595-5056
0595-5065
0595-5074
6.5 FOOT
0595-5083
0595-5092
0595-5101
16
0595-5048
0595-5057
0595-5066
0595-5075
0595-5084
0595-5093
0595-5102
18
0595-5049
0595-5058
0595-5067
0595-5076
0595-5085
0595-5094
0595-5103
20
0595-5050
0595-5059
0595-5068
0595-5077
7.0 FOOT
0595-5086
0595-5095
0595-5104
16
0595-5051
0595-5060
0595-5069
0595-5078
0595-5087
0595-5096
0595-5105
18
0595-5052
0595-5061
0595-5070
0595-5079
0595-5088
0595-5097
0595-5106
20
0595-5053
0595-5062
0595-5071
0595-5080
0595-5089
0595-5098
0595-5107
PLATFORMS
ITEM
B
ITEM
1
8 FOOT
6.0 FOOT
6.5 FOOT
7.0 FOOT
6.0 FOOT
6.5 FOOT
7.0 FOOT
25K
9515-5054
9515-5058
9515-5062
25K
9515-5066
9515-5070
9515-5074
30K
9515-5055
9515-5059
9515-5063
30K
9515-5067
9515-5071
9515-5075
35K
9515-5056
9515-5060
9515-5064
35K
9515-5068
9515-5072
9515-5076
40K
9515-5057
9515-5061
9515-5065
40K
9515-5069
9515-5073
9515-5077
45K
9515-5102
9515-5106
9515-5110
45K
9515-5114
9515-5118
9515-5122
55K
9515-5103
9515-5107
9515-5111
55K
9515-5115
9515-5119
9515-5123
75K
9515-5104
9515-5108
9515-5112
75K
9515-5116
9515-5120
9515-5124
100K
9515-5105
9515-5109
9515-5113
100K
9515-5117
9515-5121
9515-5125
10 FOOT
QTY
12 FOOT
6.0 FOOT
6.5 FOOT
7.0 FOOT
25K
9515-5090
9515-5094
9515-5098
9515-5087
30K
9515-5091
9515-5095
9515-5099
9515-5084
9515-5088
35K
9515-5092
9515-5096
9515-5100
9515-5081
9515-5085
9515-5089
40K
9515-5093
9515-5097
9515-5101
45K
9515-5126
9515-5130
9515-5134
45K
9515-5138
9515-5142
9515-5146
55K
9515-5127
9515-5131
9515-5135
55K
9515-5139
9515-5143
9515-5147
75K
9515-5128
9515-5132
9515-5136
75K
9515-5140
9515-5144
9515-5148
100K
9515-5129
9515-5133
9515-5137
100K
9515-5141
Provide dock leveler serial number, platform size, and lip size when calling or faxing orders.
9515-5145
9515-5149
B
1
6 FOOT
QTY
1
6.0 FOOT
6.5 FOOT
7.0 FOOT
25K
9515-5078
9515-5082
9515-5086
30K
9515-5079
9515-5083
35K
9515-5080
40K
* For left/right orientation of dock leveler, see inside back cover of this manual.
4111-0018 — May 2015
49
PARTS
ITEM
QTY
BASE FRAMES
6 FOOT
10 FOOT
24 INCH PIT
8 FOOT
12 FOOT
24 INCH PIT
25K/55K
6.0 FOOT
16
1
8435-5027
16
8435-5030
16
5435-5033
16
8435-5036
18
8435-5028
18
8435-5031
18
8435-5034
18
8435-5037
20
8435-5029
20
8435-5032
20
8435-5035
20
8435-5038
16
8435-5039
16
8435-5042
16
8435-5045
16
8435-8048
18
8435-5040
18
8435-5043
18
8435-5046
18
8435-5049
20
8435-5041
20
8435-5044
20
8435-5047
20
8435-5050
6.5 FOOT
1
7.0 FOOT
1
16
8435-5051
16
8435-5054
16
8435-5057
16
8435-5060
18
8435-5052
18
8435-5055
18
8435-5058
18
8435-5061
20
8435-5053
20
8435-5056
20
8435-5059
20
8735-5062
8435-5069
16
8435-5072
75K(24 INCH PIT)
6.0 FOOT
16
1
L
8435-5063
16
8435-5066
16
18
8435-5064
18
8435-5037
18
8435-5070
18
8435-5073
20
8435-5065
20
8435-5068
20
8435-5071
20
8435-5074
16
8435-5075
16
8435-5078
16
8435-5081
16
8435-5084
6.5 FOOT
1
18
8435-5076
18
8435-5079
18
8435-5082
18
8435-5085
20
8435-5077
20
8435-5080
20
8435-5083
20
8435-5086
16
8435-5087
16
8435-5090
16
8435-5093
16
8435-5096
7.0 FOOT
1
18
8435-5088
18
8435-5091
18
8435-5094
18
8435-5097
20
8435-5089
20
8435-5092
20
8435-5095
20
8435-5098
100K (24 INCH PIT)
6.0 FOOT
1
16
8435-5099
16
8435-5102
16
8435-5105
16
8435-5108
18
8435-5100
18
8435-5103
18
8435-5106
18
8435-5109
20
8435-5101
20
8435-5104
20
8435-5107
20
8435-5110
6.5 FOOT
1
16
8435-5111
16
8435-5114
16
8435-5117
16
8435-5120
18
8435-5112
18
8435-5115
18
8435-5118
18
8435-5121
20
8435-5113
20
8435-5116
20
8435-5119
20
8435-5122
16
8435-5123
16
8435-5129
16
8435-5129
16
8435-5132
7.0 FOOT
1
50
18
8435-5124
18
8435-5127
18
8435-5130
18
8435-5133
20
8435-5125
20
8435-5128
20
8435-5131
20
8435-5134
4111-0018 — May 2015
PARTS
LIP SHAFTS 25K-100K
6.0 FOOT
DPLA-2101
6.5 FOOT
DPLA-2102
7.0 FOOT
DPLA-2103
C
2
ITEM
QTY
PART NUMBER
D
4
DOTH-2355
PIN, CLEVIS
E
4
DOTH-2373
PIN, COTTER
F
2
DOTH-2160
NUT, HEX 5/8-11 UNC
G
2
DOTH-2074
BOLT, 5/8-11 UNC X 2.00 INCH
H
2
DOTH-2382
PIN, COTTER 1/4 X 2
J
1
9201-0006
PROP PIN AND CLIP
8432-1129
KEEPER LIP 16
8432-1130
KEEPER LIP 18
8432-1131
KEEPER LIP 20
8432-1132
KEEPER LIP 16 (24 PIT)
8432-1133
KEEPER LIP 18 (24 PIT)
8432-1134
KEEPER LIP 20 (24 PIT)
K
2
4111-0018 — May 2015
DESCRIPTION
51
PARTS
Hydraulic Components
52
4111-0018 — May 2015
PARTS
Hydraulic Components
Item
0525-0111
MAIN CYLINDER 3 x 18”
1
0525-0112
MAIN CYLINDER 4 x 18” ( 75K and 100K)
1
111-275
SEAL KIT MAIN CYL.3 x 18”
1
111-274
SEAL KIT MAIN CYL. 4 x 18”
3
1
0525-0113
4
1
111-094
SEAL KIT LIP CYLINDER
5
1
1
111-374
111-375
MOTOR PUMP ASSY. 1PH
MOTOR PUMP ASSY. 3PH
5A
1
9391-0055
9391-0051
6
1
111-077
HOSE ASSEMBLE MAIN
1
111-075
HOSE ASSEMBLY LIP 6 FOOT LONG
1
111-078
HOSE ASSEMBLY LIP 8 FOOT LONG
1
111-078
HOSE ASSEMBLY LIP 10 FOOT LONG
1
111-074
HOSE ASSEMBLY MAIN TO LIP 6-8 FOOT LONG
1
111-079
HOSE ASSEMBLY MAIN TO LIP 10 FOOT LONG
9
1
111-212
HOSE ASSEMBLY BOTTOM OF MAIN TO TOP
10
1
111-170
FITTING, ELBOW SWIVEL
11
1
111-071
FITTING, ELBOW
11A
1
111-206
VALVE, SOLENOID (OPTIONAL) REPLACES ITEM #11
FOR E-STOP OR INDEPENDENT LIP
12
1
111-220
FUSE, VELOCITY
12A
1
111-366
FUSE, VELOCITY WITH E-STOP OR LIP OUT
13
1
111-208
FITTING, TEE
14
1
111-210
FITTING, TEE
15
2
111-070
FITTING, ELBOW
16
2
17
4
19
4
2
7
8
2
Part Number Description
1
1
1
QTY
LIP CYLINDER
MOTOR PUMP ASSY. 1PH DUAL MAIN CYL
MOTOR PUMP ASSY. 3PH DUAL MAIN CYL
DOTH-2738 FITTING, ELBOW SWIVEL
113-264
PIN, CLEVIS LIP
DOTH-2382 PIN COTTER
Provide length and diameter of hose when calling or faxing orders.
Provide dock leveler serial number, voltage, and phase when calling or faxing orders.
4111-0018 — May 2015
53
PARTS
Weather Seal, Rubber Style and Toe Guards
9
10
11
12
5
1
3
6
7
4
*
2
6 FOOT
8 FOOT
10 FOOT
1
1
0014-0062 TOE GUARD LH MIDDLE
0014-0070 TOE GUARD LH MIDDLE
0014-0078 TOE GUARD LH MIDDLE
2
1
0014-0066 TOE GUARD LH LOWER
0014-0074 TOE GUARD LH LOWER
0014-0082 TOE GUARD LH LOWER
3
1
0014-0064 TOE GUARD RH MIDDLE
0014-0072 TOE GUARD RH MIDDLE
0014-0080 TOE GUARD RH MIDDLE
4
1
0014-0068 TOE GUARD RH LOWER
0014-0076 TOE GUARD RH LOWER
0014-0084 TOE GUARD RH LOWER
5
2
OTH-2043 SCREW CAP
OTH-2043 SCREW CAP
OTH-2043 SCREW CAP
6
6
OTH-2207 WASHER
OTH-2207 WASHER
OTH-2207 WASHER
OTH-2131 LOCK NUT
OTH-2131 LOCK NUT
OTH-2131 LOCK NUT
7
2
9
2
DOTH-2841 CHANNEL WEATHER SEAL DOTH-2818 CHANNEL WEATHER SEAL DOTH-2843 CHANNEL WEATHER SEAL
10
2
DOTH-2824 T-RUBBER WEATHER SEAL DOTH-2824 T-RUBBER WEATHER SEAL CONSULT FACTORY
11
2
DOTH-2822 BRUSH WEATHER SEAL
DOTH-2822 BRUSH WEATHER SEAL
CONSULT FACTORY
12
2
DOTH-2820 EXTRUSION ALUM.
DOTH-2820 EXTRUSION ALUM.
CONSULT FACTORY
*
1
DKIT-9179 FRTG. COMPLETE R&L
DKIT-9180 FRTG. COMPLETE R&L
DKIT-9181 FRTG. COMPLETE R&L
54
4111-0018 — May 2015
PARTS Motor and Pump
1
2
111-374
RESERVOIR, PUMP WITH MOTOR DRIVE PLATE SINGLE PHASE
111-375
RESERVOIR, PUMP WITH MOTOR DRIVE PLATE THREE PHASE
Provide dock leveler serial number and type of installation when calling or faxing orders.
Provide dock leveler serial number, voltage, and phase when calling or faxing orders.
4111-0018 — May 2015
55
MISCELLANEOUS
NOTES
56
4111-0018 — May 2015
MISCELLANEOUS
Customer Information
A
NOTE: Refer to illustration for left/right orientation of
dock leveler.
The model/serial number decal (A) is located
on the left platform joist near the front (lip) of
dock leveler.
When you receive your HP/H dock leveler, write down
the dock leveler model and serial number in the form
provided. This will help ensure safe keeping of the
numbers in the event the model/serial number decal
(A) becomes lost or damaged.
Also, write down McGuire’s job number, the company
that installed the dock leveler, and the original owner’s
name. This will all help to identify the specific dock
leveler if more information is required.
When ordering, use part numbers and description
to help identify the item ordered. Do not use “item”
numbers. These are only for locating the position of
the parts. Always give dock leveler MODEL NUMBER
and/or SERIAL NUMBER.
For service, call or contact:
Dock Leveler Information
Model ___________________________________
Serial No._________________________________
Systems Job No.___________________________
Original Owner Information
Name ___________________________________
Address _________________________________
_________________________________
Installer Information
Name ___________________________________
Address _________________________________
_________________________________
Date of Installation _________________________
Systems, Inc.
P.O. Box 309
Germantown, WI 53022
Phone:(800) 624-8473
Fax: (262) 255-9399
4111-0018 — May 2015
57
STANDARD PRODUCT WARRANTY
SYSTEMS, INC. warrants that its products will be free from defects in design, materials and
workmanship for a period of one (1) year from the date of shipment. All claims for breach of this
warranty must be made within 30 days after the defect is or can with reasonable care, be detected.
In no event shall any claim be made more than 30 days after this warranty has expired. In order to
be entitled to the benefits of this warranty, the product must have been properly installed, maintained
and operated in accordance with all manufacturer’s recommendations and/or specified design
parameters and not otherwise have been subject to abuse, misuse, misapplication, acts of nature,
overloading, unauthorized repair or modification, application in a corrosive environment or lack of
maintenance. Periodic lubrication, adjustment and inspection in accordance with all manufacturers’
recommendations are the sole responsibility of the Owner/User.
In the event of a defect, as determined by SYSTEMS INC., covered by this warranty, SYSTEMS
INC. shall remedy such defect by repairing or replacing any defective equipment or parts, bearing
the cost for the parts, labor and transportation. This shall be exclusive remedy for all claims whether
based on contract, negligence or strict liability.
WARRANTY LIMITATIONS
THE ABOVE WARRANTIES ARE IN LIEU OF ANY OTHER WARRANTIES, WHETHER
EXPRESSED OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY
OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SYSTEMS INC. AND
ITS SUBSIDIARIES SHALL NOT IN ANY EVENT BE LIABLE TO ANYONE, INCLUDING THIRD
PARTIES, FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES OF ANY KIND
INCLUDING BUT NOT LIMITED TO, BREACH OF WARRANTY, LOSS OF USE, LOSS OF
PROFIT, INTERRUPTION OF BUSINESS OR LOSS OF GOODWILL.
PRODUCT SPECIFIC WARRANTY
“HP-H” SERIES LEVELER
In addition to the “Standard Product Warranty” provided with all McGuire Products,
Systems Inc., guarantees materials, components and workmanship to be free of defects for
the following extended periods:
• Structural Warranty (HP) – For a period of five (5) years from the date of shipment,
product will carry a prorated structural warranty. This warranty specifically applies to;
the deck section, lip section, frame, rear hinge assembly and front hinge assembly only.
• Hydraulic Warranty (HP) – For a period of five (5) years from date of shipment, product
will carry a prorated warranty this warranty specifically applies to; the hydraulic pump
and motor, all hydraulic cylinders, hydraulic pressure lines and fittings only.
• Structural Warranty (H) – For a period of five (5) years from the date of shipment,
this warranty specifically applies to; the deck section, lip section, frame, rear hinge
assembly and front hinge assembly only.
• Hydraulic Warranty (H) – For a period of five (5) years from date of shipment, this
warranty specifically applies to; the hydraulic pump and motor, all hydraulic cylinders,
hydraulic pressure lines and fittings only.

advertisement

Key Features

  • Hydraulic operation
  • One-button operation
  • Automatic return to dock
  • Compensates for height difference
  • Easy maintenance

Frequently Answers and Questions

What is the maximum height difference the HP-H dock leveler can compensate for?
The HP-H dock leveler can compensate for a maximum of ± 12 inches of height difference between the loading dock and the transport vehicle bed.
How do I operate the HP-H dock leveler?
The HP-H dock leveler is operated with a single button. Depress and hold the RAISE button to raise the platform. Release the button to lower the platform.
What kind of maintenance does the HP-H dock leveler require?
The HP-H dock leveler requires a simple program of preventive maintenance to ensure optimal performance.

Related manuals

Download PDF

advertisement