Technical parameters
Wireless switch unit RFSA-61M , RFSA-66M
1M
EXTERNAL ANTENNA AN-E
3M
RFSA-61M
RFSA-66M
Technical parameters
Supply voltage:
Apparent input:
Dissipated power:
Supply voltage tolerance:
Output
Number of contacts:
• RFSA-61M: the switching unit with 1 output channel is used for controlling appliances, sockets or lights.
- the one-module design of the unit into a switchboard enables connection of a switched load up to 16A (4.000 W).
- the switching unit may be controlled by up to 32 channels (1 channel represents 1 button on the controller).
• RFSA-66M: the switching unit with 6 output channels is used for independent control of up to 6 appliances,
sockets or lights. It is possible to assign any function to each output relay.
- the three-module design of the unit into a switchboard enables connection of a switched load 6 x 8A (6 x 2000W).
- it is just right for creating scenes, where with one push of the controller, you can switch on or off all 6 channels
simultaneously.
- each of the channels may be controlled by up to 32 channels (1 channel represents one button on the controller).
• It can be combined with Control or System units iNELS RF Control.
• The integrated switching contact enables connection, where the controlled appliance may be switched on or off
by command.
• Function: button, impulse relay and time function of delayed start or return with time setting range of 2s-60 min.
• The programming button on the unit is also used for manual control of the output.
• The package includes an internal antenna AN-I, in case of locating the element in a metal switchboard, you can
use the external antenna AN-E for better signal reception.
• Range up to 200 m (in open space), if the signal is insufficient between the controller and unit, use the signal
repeater RFRP-20.
• Communication frequency with bidirectional protocol iNELS RF Control.
RFSA-61M/230V RFSA-61M/24V RFSA-66M/230V RFSA-66M/24V
110-230VAC/50-60Hz 12-24 V AC/DC SELV 110-230VAC/50-60Hz 12-24 V AC/DC SELV
min. 2VA /max. 5VA
2.7 VA / cos φ = 0.6
1.62 W
0.8 W
min.0.5W/max.2.5W max. 1.8 W
+10% / -25 %
3x switching (AgSnO2)
3x switching (AgSnO2)
8 A / AC1
2000 VA / AC1
10 A / <3 s
250 V AC1
500 mW
1x107
1x105
1x switching (AgSnO2)
16 A / AC1
4000 VA / AC1, 384 W / DC
30 A / <3 s
250 V AC1 / 24 V DC
500 mW
3x107
0.7x105
Rated current:
Switching power:
Peak current:
Switching voltage:
Max. DC switching power:
Mechanical service life:
Electrical service life (AC1):
Control
RF, by command from transmitter:
Manual control:
Range in free space:
Output for antenna:
Other data
Operating temperature:
Operating position:
Mounting:
Protection:
Overvoltage category:
Contamination degree:
Function
For more information, see p. 56.
Device description
Power supply terminals
Power supply indication
IDevice status
indicator
Antenna connector
868 MHz, 915 MHz, 916 MHz
PROG (ON/OFF) button
up to 200 m
SMA connector*
Program button
(manual control)
-15 °C to + 50 °C
any
DIN rail EN 60715
IP20 from the front panel
III.
2
max. 1x2.5, max. 2x1.5 / with a hollow max. 1x2.5
90 x 17.6 x 64 mm
90 x 52 x 65 mm
74 g
137 g
264 g
310 g
EN 60669, EN 300 220, EN 301 489
R&TTE Directive, Order. No 426/2000 Coll. (Directive 1999/EC)
Connecting conductor cross-section (mm2):
Dimensions:
Weight:
Related standards:
Output relay contacts
* Max Tightening Torque for antenna connector is 0.56 Nm.
Connection
RFSA-61M/230V
RFSA-61M/24V
RFSA-66M/230V
Un
A1
A2
15 16 18
28
RFSA-66M/24V
L
N
12-24 V
AC/DC
A1 A2
18 15 28 25 38 35
45 46 48 55 56 58 65 66 68
A1 A2
18 15 28 25 38 35
45 46 48 55 56 58 65 66 68
Switches
Single function RFSA-11B
Function button ON/OFF
The output contact closes by pressing one button position, and opens by pressing the other button position.
Multi function RFSA-61B, RFSA-62B, RFSA-61M, RFSA-66M, RFSAI-61B, RFSC-61, RFUS-61
Function 1 - button
Function 2 - switch on
Function 3 - switch off
The output contact will be closed by pressing the button and
opened by releasing the button.
The output contact will be closed by pressing the button.
The output contact will be opened by pressing the button.
Function 4 - impulse relay
Funcion 5 - delayed off
Function 6 - delayed on
The output contact will be switched to the opposite position
by each press of the button. If the contact was closed, it will be
opened and vice versa.
The output contact will be closed by pressing the button and
opened after the set time interval has elapsed.
t = 2s...60min.
The output contact will be opened by pressing the button and
closed after the set time interval has elapsed.
t = 2s...60min.
Loadability products
RFJA-12B; RFSA-62B; RFSA-66M; RFSTI-11/G; RFGSM-220M
Load type
Contact material AgSnO2
Contact 8A
cos φ ≥ 0.95
M
AC1
AC2
250V / 8A
250V / 5A
HAL.230V
AC3
AC5a without
compensation
AC5a with compensation
AC5b
AC6a
AC7b
AC12
250V / 4A
x
x
250W
250V / 4A
250V / 1A
250V / 1A
M
M
K
Load type
Contact material AgSnO2
Contact 8A
M
AC13
AC14
AC15
DC1
DC3
DC5
DC12
DC13
DC14
x
250V / 4A
250V / 3A
30V / 8A
24V /3A
30V / 2A
30V / 8A
30V / 2A
x
AC5a with compensation
230V / 3A (690VA)
up to max input C=14uF
AC5b
AC6a
AC7b
AC12
1000W
x
250V / 3A
x
M
M
RFUS-61
Load type
Contact material AgSnO2
Contact 14A
cos φ ≥ 0.95
M
M
AC1
AC2
AC3
AC5a without
compensation
250V / 14A
250V / 5A
250V / 3A
230V / 3A (690VA)
K
Load type
Contact material AgSnO2
Contact 14A
HAL.230V
AC13
AC14
AC15
DC1
DC3
DC5
DC12
DC13
DC14
x
250V / 6A
250V / 6A
24V / 10A
24V / 3A
24V / 2A
24V / 6A
24V / 2A
x
RFSA-11B; RFSA-61B; RFSA-61M; RFSTI-11B; RFDAC-71B , RFSC-61, RFSAI-61B
Load type
Contact material AgSnO2
Contact 16A
cos φ ≥ 0.95
M
56
HAL.230V
AC1
AC2
AC3
AC5a without
compensation
250V / 16A
250V / 5A
250V / 3A
230V / 3A (690VA)
K
Load type
Contact material AgSnO2
Contact 16A
M
AC5a with compensation
230V / 3A (690VA)
up to max input C=14uF
AC5b
AC6a
AC7b
AC12
1000W
x
250V / 3A
250V / 10A
M
M
AC13
AC14
AC15
DC1
DC3
DC5
DC12
DC13
DC14
x
250V / 6A
250V / 6A
24V 10A
24V /3A
24V /2A
24V / 6A
24V / 2A
x