MODEL: AC A8: Specify voltage (Input resistance 100 kΩ min.) ( 0 % input must be 0 V.) Plug-in Signal Conditioners M-UNIT AC TRANSMITTER Functions & Features • Converting an alternating current/voltage into a standard process signal • True RMS sensing • Isolation up to 2000 V AC • LCD meter (engineering unit display selectable) • Simple loop test output (0 % and 100 %) • High-density mounting Typical Applications • Converting a large AC current in combination with a shunt resistor, or a narrow span AC voltage 50 (1.97) 80 (3.15) 127 (5) mm (inch) ORDERING INFORMATION •Code number: AC-[1][2]-[3][4] Specify a code from below for each [1] through [4]. (e.g. AC-A1A-B/E2) •Special input and output ranges for codes AZ, A8, Z & 0 Current AA: 0 – 10 mA AC (Input resistance 100 Ω) AB: 0 – 50 mA AC (Input resistance 20 Ω) AC: 0 – 100 mA AC (Input resistance 10 Ω) AD: 0 – 500 mA AC (Input resistance 1 Ω) AZ: Specify current (See INPUT SPECIFICATIONS) ( 0 % input must be 0 mA.) Voltage A1: 0 – 100 mV AC (Input resistance 100 kΩ min.) A2: 0 – 500 mV AC (Input resistance 100 kΩ min.) A3: 0 – 1 V AC (Input resistance 100 kΩ min.) A4: 0 – 5 V AC (Input resistance 100 kΩ min.) A5: 0 – 10 V AC (Input resistance 100 kΩ min.) A6: 0 – 120 V AC (Input resistance 100 kΩ min.) A7: 0 – 150 V AC (Input resistance 100 kΩ min.) http://www.m-system.co.jp/ Current A: 4 – 20 mA DC (Load resistance 750 Ω max.) B: 2 – 10 mA DC (Load resistance 1500 Ω max.) C: 1 – 5 mA DC (Load resistance 3000 Ω max.) D: 0 – 20 mA DC (Load resistance 750 Ω max.) E: 0 – 16 mA DC (Load resistance 900 Ω max.) F: 0 – 10 mA DC (Load resistance 1500 Ω max.) G: 0 – 1 mA DC (Load resistance 15 kΩ max.) Z: Specify current (See OUTPUT SPECIFICATIONS) Voltage 1: 0 – 10 mV DC (Load resistance 10 kΩ min.) 2: 0 – 100 mV DC (Load resistance 100 kΩ min.) 3: 0 – 1 V DC (Load resistance 100 Ω min.) 4: 0 – 10 V DC (Load resistance 1000 Ω min.) 5: 0 – 5 V DC (Load resistance 500 Ω min.) 6: 1 – 5 V DC (Load resistance 500 Ω min.) 4W: -10 – +10 V DC (Load resistance 2000 Ω min.) 5W: -5 – +5 V DC (Load resistance 1000 Ω min.) 0: Specify voltage (See OUTPUT SPECIFICATIONS) [3] POWER INPUT MODEL: AC–[1][2]–[3][4] [1] INPUT [2] OUTPUT AC Power B: 100 V AC C: 110 V AC D: 115 V AC F: 120 V AC G: 200 V AC H: 220 V AC J: 240 V AC DC Power S: 12 V DC R: 24 V DC V: 48 V DC P: 110 V DC (Not selectable with Option /E2) [4] OPTIONS Input Signal Indicator blank: Without /E: With (0.0 - 100.0 % display) /E2: With (in engineering unit with backlight and the simple loop test output) GENERAL SPECIFICATIONS Construction: Plug-in Connection: M3.5 screw terminals Housing material: Flame-resistant resin (black) AC SPECIFICATIONS ES-1361 Rev.7 Page 1/3 MODEL: AC Isolation: Input to output to power Input waveform RMS sensing: Up to 15 % of 3rd harmonic content Overrange output: 0 to 120 % at 1 – 5 V Zero adjustment: -5 to +5 % (front) Span adjustment: 95 to 105 % (front) Display scaling: -10000 – +10000; ex-factory set to 0.00 – 100.00 (%) Engineering unit: %, μV, mV, V, mA, A, °C, °F, Ω or DEG K, mHz, Hz, kHz, VAC, AAC, mg, g, kg, t, rpm, rps selectable Simple loop test output: 0 % and 100 % signal simulated by selecting the front switch positions. INPUT SPECIFICATIONS Frequency: 40 Hz min., 1 kHz max. with 100% input • AC Current: 0 – 1 A AC; input resistor incorporated Minimum span: 1 mA Input resistance Span 1 mA: 1 kΩ Span ≤ 2 mA: 500 Ω Span ≤ 5 mA: 200 Ω Span ≤ 10 mA: 100 Ω Span ≤ 20 mA: 50 Ω Span ≤ 50 mA: 20 Ω Span ≤ 100 mA: 10 Ω Span ≤ 500 mA: 1 Ω Span ≤ 1 A: 0.5 Ω • AC Voltage: 0 – 250 V AC Minimum span: 50 mV Input resistance: 100 kΩ min. Operating humidity: 30 to 90 %RH (non-condensing) Mounting: Surface or DIN rail Weight: 400 g (0.88 lbs) PERFORMANCE in percentage of span Accuracy: ±0.4 % Display accuracy: ±(0.4 % of FS + 1 digit) Simple loop test output setting accuracy: ±0.5 % Temp. coefficient: ±0.05 %/°C (±0.03 %/°F) Response time: ≤ 0.7 sec. (0 – 90 %) Ripple: 0.5 %p-p max. Line voltage effect: ±0.1 % over voltage range Insulation resistance: ≥ 100 MΩ with 500 V DC Dielectric strength: 2000 V AC @1 minute (input to output to power to ground) OUTPUT SPECIFICATIONS • DC Current: 0 – 20 mA DC Minimum span: 1 mA Offset: Max. 1.5 times span Load resistance: Output drive 15 V max. • DC Voltage: -10 – +12 V DC Minimum span: 5 mV Offset: Max. 1.5 times span Load resistance: Output drive 10 mA max.; 5 mA for negative voltage output; at ≥ 0.5 V INSTALLATION Power input •AC: Operational voltage range: rating ±10 %, 50/60 ±2 Hz, approx. 2 VA (approx. 3 VA with Option /E2) •DC: Operational voltage range: rating ±10 %, or 85 – 150 V for 110 V rating (ripple 10 % p-p max.) approx. 2 W (80 mA at 24 V; approx. 3 W with Option /E2) Operating temperature: -5 to +60°C (23 to 140°F) http://www.m-system.co.jp/ AC SPECIFICATIONS ES-1361 Rev.7 Page 2/3 MODEL: AC EXTERNAL VIEW ■ OPTION/E ■ OPTION/E2 Zero Adj. Span Adj. Zero Adj. Span Adj. NEXT Key Loop Test Selector ENTER Key Top : 0% fixed Middle : 100% fixed Bottom : Cancel (normal operating mode) DIMENSIONS unit: mm (inch) CLAMP (top & bottom) 20 (.79) 7.8 (.31) 5 4 3 7 8 1 2 2–4.5 (.18) dia. MTG HOLE 15 (.59) deep 8–M3.5 SCREW 50 (1.97) 6 80 (3.15) 80 (3.15) 35.4 (1.39) DIN RAIL 35mm wide 107 (4.21) 40 (1.57) 127 (5) [3.3 (.13)] 50 (1.97) • When mounting, no extra space is needed between units. SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM ** Isolation 3 INPUT * AC Amplifier R.M.S. Operation Z S Output Driver 4 LOOP TEST SELECTOR 5 1 + OUTPUT *** 2 – 7 U(+) 6 POWER 8 V(–) Base Socket * Input shunt resistor incorporated for current input. ** Option /E, E2 *** Option /E2 Specifications are subject to change without notice. http://www.m-system.co.jp/ AC SPECIFICATIONS ES-1361 Rev.7 Page 3/3
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement