2 © Siemens AG 2011 LOGO! logic module 2/2 2/2 Introduction LOGO! logic module 2/3 2/3 2/6 2/8 2/11 2/13 2/18 2/22 LOGO! modular LOGO! modular basic versions SIPLUS LOGO! modular basic versions LOGO! modular pure versions SIPLUS LOGO! modular pure versions LOGO! modular expansion modules SIPLUS LOGO! modular expansion modules LOGO! CM EIB/KNX communication module AS-Interface connection for LOGO! 2/23 2/23 2/33 LOGO!Power LOGO!Power SIPLUS LOGO!Power 2/35 LOGO!Contact 2/36 LOGO! software 2/21 Brochures For brochures serving as selection guides for SIMATIC products refer to: http://www.siemens.com/simatic/ printmaterial Siemens ST 70 · 2011 © Siemens AG 2011 LOGO! logic module Introduction LOGO! logic module ■ Overview ■ General technical data of the SIPLUS LOGO 2 Ambient temperature range -40/-25 ... +70 °C Conformal coating Coating of the printed circuit boards and the electronic components Technical data The technical data of the standard product applies except for the ambient conditions. Ambient conditions LOGO! logic module • The compact, easy-to-use and low-cost solution for simple control tasks • Compact, easy to operate, universally applicable without accessories • "All in one": Integrated display and operator panel • 36 different functions can be connected at the click of a button or by means of PC software; up to 130 times over • Functions are easily changed at the press of a key. No more time-consuming rewiring SIPLUS LOGO! • The controller for use in the toughest ambient conditions • With extended temperature range from -40/-25 °C to +70 °C • Suitable for medial exposure (harmful gas atmosphere) • Condensation permissible • With the proven PLC technology of LOGO! • Easy to handle, program, maintain, and service • Ideal for use in automotive engineering, environmental engineering, mining, chemical plants, conveying technology, food industry, etc. Accessories: • The front plate mounting set also allows simple and reliable installation of the logic modules in front plates; IP65 protection is thus possible. • In order to ensure dependable operation of SIPLUS devices supplied by the battery in conjunction with combustion engines, it is necessary to put in a SIPLUS upmiter upstream device between the battery and the SIPLUS LOGO!. For further information, please go to: www.siemens.com/siplus-extreme For brochures serving as selection guides for SIMATIC products refer to: www.siemens.com/simatic/printmaterial 2/2 Siemens ST 70 · 2011 Relative humidity 5 ... 100%, condensation allowed Biologically active substances Conformity with EN 60721-3-3, Class 3B2 mold and fungal spores (except fauna) Chemically active substances Conformity with EN 60721-3-3, Class 3C4 incl. salt mist and ISA– S71.04 severity level G1; G2; G3; GX 1)2) Mechanically active substances Conformity with EN 60721-3-3, Class 3S4 including conductive sand, dust 2) Air pressure (depending on the highest positive temperature range specified) 1080 ... 795 hPa (-1000 ... +2000 m) see ambient temperature range 795 ... 658 hPa (+2000 ... 3500 m) derating 10 K 658 ... 540 hPa (+3500 ... +5000 m) derating 20 K 1) 2) ISA-S71.04 severity level GX: Long-term load: SO2 < 4.8 ppm; H2S < 9.9 ppm; Cl < 0.2 ppm; HCl < 0.66 ppm; HF < 0.12 ppm; NH < 49 ppm; O3 < 0.1 ppm; NOX < 5.2 ppm Limit value (max. 30 min/d): SO2 < 17.8 ppm; H2S < 49.7 ppm; Cl < 1.0 ppm; HCl < 3.3 ppm; HF < 2.4 ppm; NH < 247 ppm; O3 < 1.0 ppm; NOX < 10.4 ppm The supplied plug covers must remain in place over the unused interface when operated in atmospheres containing corrosive gases! © Siemens AG 2011 LOGO! logic module LOGO! modular LOGO! modular basic versions ■ Overview • The space-saving basic versions • Interface for the connection of expansion modules, up to 24 digital inputs, 16 digital outputs, 8 analog inputs and 2 analog outputs can be addressed • With connection option for LOGO! TD text display (can be connected to all LOGO! 0BA6 basic versions) ■ Technical specifications Supply voltages Rated value • 12 V DC • 24 V DC • 115 V DC • 230 V DC • Permissible range, lower limit (DC) • Permissible range, upper limit (DC) • 24 V AC • 115 V AC • 230 V AC • Permissible range, lower limit (AC) • Permissible range, upper limit (AC) Time Time switching clocks • Power reserve 6ED1 052-1CC01-0BA6 6ED1 052-1MD00-0BA6 6ED1 052-1HB00-0BA6 Yes Yes Yes Yes 6ED1 052-1FB00-0BA6 20.4 V 10.8 V 20.4 V Yes Yes 100 V 28.8 V 28.8 V 28.8 V 253 V Yes 20.4 V Yes Yes 85 V 26.4 V 265 V 80 h 80 h 80 h 80 h 8; of which 4 can be used in analog mode (0 to 10 V) 8; of which 4 can be used in analog mode (0 to 10 V) 8 8 Digital outputs Number of digital outputs 4; Transistor 4; Relay 4; Relay 4; Relay Short-circuit protection Yes; electrical (1 A) No; external fusing necessary No; external fusing necessary No; external fusing necessary Output current • for signal "1" permissible range for 0 to 55 °C, max. 0.3 A 3A 10 A 3A 10 A 3A 10 A Yes Yes Yes Digital inputs Number of digital inputs Relay outputs Switching capacity of contacts • with inductive load, max. • with resistive load, max. EMC Emission of radio interference acc. to EN 55 011 • Emission of radio interference acc. to EN 55 011 (limit value class B) Yes; Radio interference suppression according to EN55011, limit value class B Siemens ST 70 · 2011 2/3 2 © Siemens AG 2011 LOGO! logic module LOGO! modular LOGO! modular basic versions ■ Technical specifications (continued) 2 6ED1 052-1CC01-0BA6 6ED1 052-1MD00-0BA6 6ED1 052-1HB00-0BA6 6ED1 052-1FB00-0BA6 Environmental requirements Operating temperature • Min. • Max. 0 °C 55 °C 0 °C 55 °C 0 °C 55 °C 0 °C 55 °C Degree of protection IP20 Yes Yes Yes Yes Standards, approvals, certificates CSA approval Yes Yes Yes Yes Developed according to IEC1131 Yes Yes Yes Yes FM approval Yes Yes Yes Yes According to VDE 0631 Yes Yes Yes Yes Marine approval Yes Yes Yes Yes UL approval Yes Yes Yes Yes on 35 mm DIN rail, 4 spacing units wide 72 mm 90 mm 55 mm on 35 mm DIN rail, 4 spacing units wide 72 mm 90 mm 55 mm on 35 mm DIN rail, 4 spacing units wide 72 mm 90 mm 55 mm on 35 mm DIN rail, 4 spacing units wide 72 mm 90 mm 55 mm Dimensions and weight Dimensions • Mounting • Width • Height • Depth ■ Ordering data LOGO! logic module 24C Order No. I 6ED1 052-1CC01-0BA6 SIPLUS LOGO! TD text display 6ED1 052-1MD00-0BA6 6AG1 055-4MH00-2BA0 (extended temperature range -10 ... +60 °C and medial exposure) 4-line text display, can be connected to all LOGO! 0BA6 Basic and Pure versions, including connecting cable LOGO! manual 6ED1 052-1HB00-0BA6 24 V AC/DC power supply, 8x 24 V AC/DC digital inputs, 4x 10 A relay outputs, integral time switch; 200 function blocks can be interlinked, modular expansion capability LOGO! logic module 230RC 6ED1 055-4MH00-0BA0 4-line text display, can be connected to all LOGO! 0BA6 Basic and Pure versions, including connecting cable 12/24 V DC power supply, 8 x 12/24 V DC digital inputs, of which 4 can be used in analog mode (0 to 10 V), 4 x 10 A relay outputs, integrated time switch; 200 function blocks can be interlinked, modular expansion capability LOGO! logic module 24RC Accessories LOGO! TD text display 12/24 V DC power supply, 8x 12/24 V DC digital inputs, of which 4 can be used in analog mode (0 to 10 V), 4x 10 A relay outputs, integral time switch; 200 function blocks can be interlinked, modular expansion capability LOGO! logic module 12/24RC Order No. German 6ED1 050-1AA00-0AE7 English 6ED1 050-1AA00-0BE7 French 6ED1 050-1AA00-0CE7 Spanish 6ED1 050-1AA00-0DE7 Italian 6ED1 050-1AA00-0EE7 Chinese 6ED1 050-1AA00-0KE7 6ED1 052-1FB00-0BA6 115/230 V AC/DC power supply, 8x 115/230 V AC/DC digital inputs, 4x 10 A relay outputs, integral time switch; 200 function blocks can be interlinked, modular expansion capability I: Subject to export regulations AL: N and ECCN: EAR99H 2/4 Siemens ST 70 · 2011 © Siemens AG 2011 LOGO! logic module LOGO! modular LOGO! modular basic versions ■ Ordering data Order No. LOGO! Memory Card 6ED1 056-1DA00-0BA0 Program module for copying, with know-how protection 6ED1 056-6XA00-0BA0 Battery module for backing up the integral real-time clock (not LOGO! 24) LOGO! memory/battery card 6ED1 056-7DA00-0BA0 Combined program and battery module, with know-how protection and for backing up the integral real-time clock (not LOGO! 24) 6AG1 057-1AA01-0BA6 J 6ED1 058-0BA02-0YA0 For programming on the PC in LAD/FBD; executes on Windows 98 SE and higher, Linux, MAC OSX; on CD-ROM LOGO!Soft Comfort V6.0 upgrade J LOGO! PC cable 6ED1 058-0CA02-0YE0 6ED1 057-1AA00-0BA0 For program transfer between LOGO! and the PC For transferring the program between LOGO! and PC, including driver on CD-ROM Width 4 modular spacings 6AG1 057-1AA00-0AA0 Width 4 modular spacings, with keys 6AG1 057-1AA00-0AA3 Width 8 modular spacings 6AG1 057-1AA00-0AA1 Width 8 modular spacings, with keys 6AG1 057-1AA00-0AA2 Contains LOGO! 12/24RC, LOGO! USB PC cable, LOGO!Soft Comfort V6.0, manual, screwdriver, information material German J 6ED1 057-3BA00-0AA5 English J 6ED1 057-3BA00-0BA5 German J 6ED1 057-3AA02-0AA0 English J 6ED1 057-3AA02-0BA0 German J 6ED1 057-3BA10-0AA0 English J 6ED1 057-3BA10-0BA0 LOGO! News Box, 230 V Upgrade from V1.0 to V6.0 LOGO! USB PC cable 2 Front plate mounting set LOGO! News Box, 12/24 V L Programming device used to simultaneously reproduce program module contents on up to 8 program modules LOGO!Soft Comfort V6.0 6ED1 057-1CA00-0BA0 Adapter cable for analog modem communication LOGO! battery card LOGO! PROM Order No. LOGO! modem cable J 6ED1 057-1AA01-0BA0 Contains LOGO! 230RC, LOGO! USB PC cable, LOGO!Soft Comfort V6.0, manual, screwdriver, information material LOGO! TD News Box, 12/24 V Contains LOGO! 12/24RCo, LOGO! TD, LOGO! USB PC cable, LOGO! Soft Comfort V6.0, manual, screwdriver, information material J: Subject to export regulations AL: N and ECCN: EAR99S L: Subject to export regulations AL: 9I999 and ECCN: N Siemens ST 70 · 2011 2/5 © Siemens AG 2011 LOGO! logic module LOGO! modular SIPLUS LOGO! modular basic versions ■ Overview • The space-saving basic versions • Interface for the connection of expansion modules, up to 24 digital inputs, 16 digital outputs, 8 analog inputs and 2 analog outputs can be addressed • With connection option for LOGO! text display TD (can be connected to all LOGO! 0BA6 basic versions) 2 Note: SIPLUS extreme products are based on Siemens Industry standard products. The contents listed here were taken from the respective standard products. SIPLUS extreme-specific information was added. SIPLUS LOGO! 24 SIPLUS LOGO! 12/24RC SIPLUS LOGO! 24RC SIPLUS LOGO! 230RC Order number 6AG1 052-1CC01-2BA6 6AG1 052-1FB00-2BA6 6AG1 052-1HB00-2BA6 6AG1 052-1MD00-2BA6 Order No. based on 6ED1 052-1CC01-0BA6 6ED1 052-1FB00-0BA6 6ED1 052-1HB00-0BA6 6ED1 052-1MD00-0BA6 Ambient temperature range -25°C to +70 °C Conformal coating Coating of the printed circuit boards and the electronic components Technical data The technical data of the standard product applies except for the ambient conditions. Ambient conditions Relative humidity 5 ... 100 % Condensation permissible Biologically active substances Conformity with EN 60721-3-3, Class 3B2 mold and fungal spores (except fauna) Chemically active substances Conformity with EN 60721-3-3, Class 3C4 incl. salt mist and ISA–S71.04 severity level G1; G2; G3; GX 1) 2) Mechanically active substances Conformity with EN 60721-3-3, Class 3S4 including conductive sand, dust 2) Air pressure (depending on 1080 ... 795 hPa (-1000 ... +2000 m) the highest positive temper- see ambient temperature range ature range specified) 795 ... 658 hPa (+2000 ... +3500 m) derating 10 K 658 ... 540 hPa (+3500 ... +5000 m) derating 20 K 1) 2) ISA-S71.04 severity level GX: Long-term load: SO2 < 4.8 ppm; H2S < 9.9 ppm; Cl < 0.2 ppm; HCl < 0.66 ppm; HF < 0.12 ppm; NH < 49 ppm; O3 < 0.1 ppm; NOX < 5.2 ppm Limit value (max. 30 min/d): SO2 < 17.8 ppm; H2S < 49.7 ppm; Cl < 1.0 ppm; HCl < 3.3 ppm; HF < 2.4 ppm; NH < 247 ppm; O3 < 1.0 ppm; NOX < 10.4 ppm The supplied plug covers must remain in place over the unused interface when operated in atmospheres containing corrosive gases! The technical documentation on SIPLUS can be found here: www.siemens.com/siplus-extreme 2/6 Siemens ST 70 · 2011 © Siemens AG 2011 LOGO! logic module LOGO! modular SIPLUS LOGO! modular basic versions ■ Ordering data SIPLUS LOGO! 24 Order No. I 6AG1 052-1CC01-2BA6 Order No. Accessories (extended temperature range and medial exposure) SIPLUS Upmiter upstream device 24 V DC power supply, 8x 24 V DC digital inputs, of which 4 can be used in analog mode (0 to 10 V), 4x 24 V DC digital outputs, 0.3 A; integrated time switch; 200 function blocks can be interlinked, modular expansion capability for reliable operation at the battery of combustion engines SIPLUS LOGO! 12/24RC Additional accessories L L 2 6AG1 053-1AA00-2AA0 See LOGO! modular basic versions 6AG1 052-1MD00-2BA6 (extended temperature range and medial exposure) 12/24 V DC power supply, 8x 12/24 V DC digital inputs, of which 4 can be used in analog mode (0 to 10 V), 4x 10 A relay outputs, integral time switch; 200 function blocks can be interlinked, modular expansion capability SIPLUS LOGO! 24RC 6AG1 052-1HB00-2BA6 (extended temperature range and medial exposure) 24 V AC/DC power supply, 8x 24 V AC/DC digital inputs, 4x 10 A relay outputs, integral time switch; 200 function blocks can be interlinked, modular expansion capability SIPLUS LOGO! 230RC 6AG1 052-1FB00-2BA6 (extended temperature range and medial exposure) 115/230 V AC/DC power supply, 8x 115/230 V AC/DC digital inputs, 4x 10 A relay outputs, integral time switch; 200 function blocks can be interlinked, modular expansion capability I: Subject to export regulations AL: N and ECCN: EAR99H L: Subject to export regulations AL: 9I999 and ECCN: N Siemens ST 70 · 2011 2/7 © Siemens AG 2011 LOGO! logic module LOGO! modular LOGO! modular pure versions ■ Overview • The cost-optimized basic versions • Interface for the connection of expansion modules, up to 24 digital inputs, 16 digital outputs, 8 analog inputs and 2 analog outputs can be addressed • With connection option for LOGO! TD text display (can be connected to all LOGO! 0BA6 basic versions) 2 ■ Technical specifications Supply voltages Rated value • 12 V DC • 24 V DC • 115 V DC • 230 V DC • permissible range, lower limit (DC) • permissible range, upper limit (DC) • 24 V AC • 115 V AC • 230 V AC • permissible range, lower limit (AC) • permissible range, upper limit (AC) Time of day Time switching clocks • Number • Power reserve 6ED1 052-2CC01-0BA6 6ED1 052-2MD00-0BA6 6ED1 052-2HB00-0BA6 Yes Yes Yes Yes 6ED1 052-2FB00-0BA6 20.4 V 10.8 V 20.4 V Yes Yes 100 V 28.8 V 28.8 V 28.8 V 253 V Yes 20.4 V Yes Yes 85 V 26.4 V 265 V 190 80 h 8 80 h 8 80 h 8 80 h 8; of which 4 can be used in analog mode (0 to 10 V) 8; of which 4 can be used in analog mode (0 to 10 V) 8 8 Digital outputs Number of digital outputs 4; Transistor 4; Relay 4; Relay 4; Relay Short-circuit protection Yes; electrical (1 A) No; external fusing necessary No; external fusing necessary No; external fusing necessary Output current • for signal "1" permissible range for 0 to 55 °C, max. 0.3 A 3A 10 A 3A 10 A 3A 10 A Digital inputs Number of digital inputs Relay outputs Switching capacity of contacts • with inductive load, max. • with resistive load, max. 2/8 Siemens ST 70 · 2011 © Siemens AG 2011 LOGO! logic module LOGO! modular LOGO! modular pure versions ■ Technical specifications (continued) 6ED1 052-2CC01-0BA6 EMC Emission of radio interference acc. to EN 55 011 • Emission of radio interference acc. to EN 55 011 (limit value class B) 6ED1 052-2MD00-0BA6 6ED1 052-2HB00-0BA6 6ED1 052-2FB00-0BA6 2 Yes; Radio interference suppression according to EN55011, limit value class B Yes Yes Yes Environmental requirements Operating temperature • Min. • Max. 0 °C 55 °C 0 °C 55 °C 0 °C 55 °C 0 °C 55 °C Degree of protection IP20 Yes Yes Yes Yes Standards, approvals, certificates CSA approval Yes Yes Yes Yes Developed according to IEC1131 Yes Yes Yes Yes FM approval Yes Yes Yes Yes According to VDE 0631 Yes Yes Yes Yes Marine approval Yes Yes Yes Yes UL approval Yes Yes Yes Yes on 35 mm DIN rail, 4 spacing units wide 72 mm 90 mm 55 mm on 35 mm DIN rail, 4 spacing units wide 72 mm 90 mm 55 mm on 35 mm DIN rail, 4 spacing units wide 72 mm 90 mm 55 mm on 35 mm DIN rail, 4 spacing units wide 72 mm 90 mm 55 mm Dimensions and weight Dimensions • Mounting • Width • Height • Depth ■ Ordering data LOGO! logic module 24Co Order No. I 6ED1 052-2CC01-0BA6 Order No. LOGO! logic module 24RCo 24 V DC power supply, 8 digital inputs 24 V DC, of which 4 can be used in analog mode (0 to 10 V), 4 digital outputs 24 V DC, 0.3 A, integrated time switch; without display and keyboard; 200 function blocks can be interlinked, modular expansion capability 24 V AC/DC power supply, 8 digital inputs 24 V AC/DC, 4 relay outputs 10 A, integral time switch; without display and keyboard; 200 function blocks can be interlinked, modular expansion capability LOGO! logic module 12/24RCo 115/230 V AC/DC power supply, 8 digital inputs 115/230 V AC/DC, 4 relay outputs 10 A, integral time clock; without display and keyboard; 200 function blocks can be interlinked, modular expansion capability 12/24 V DC power supply, 8 digital inputs 12/24 V DC, of which 4 can be used in analog mode (0 to 10 V), 4 relay outputs 10 A, integral time switch; without display and keyboard; 200 function blocks can be interlinked, modular expansion capability LOGO! logic module 230RCo 6ED1 052-2MD00-0BA6 6ED1 052-2HB00-0BA6 6ED1 052-2FB00-0BA6 I: Subject to export regulations AL: N and ECCN: EAR99H Siemens ST 70 · 2011 2/9 © Siemens AG 2011 LOGO! logic module LOGO! modular LOGO! modular pure versions ■ Ordering data Order No. Accessories 2 Order No. LOGO! memory/battery card LOGO! TD text display 6ED1 055-4MH00-0BA0 4-line text display, can be connected to all LOGO! 0BA6 Basic and Pure versions, including connecting cable SIPLUS LOGO! TD text display Combined program and battery module, with know-how protection and for backing up the integral real-time clock (not LOGO! 24o) LOGO! PROM 6AG1 055-4MH00-2BA0 (extended temperature range -10 ... +60 °C and medial exposure) German 6ED1 050-1AA00-0AE7 LOGO!Soft Comfort V6.0 upgrade English 6ED1 050-1AA00-0BE7 Upgrade from V1.0 to V6.0 French 6ED1 050-1AA00-0CE7 LOGO! PC cable Spanish 6ED1 050-1AA00-0DE7 Italian 6ED1 050-1AA00-0EE7 For program transfer between LOGO! and the PC Chinese 6ED1 050-1AA00-0KE7 LOGO! USB PC cable LOGO! Memory Card 6ED1 056-1DA00-0BA0 For transferring the program between LOGO! and PC, including driver on CD-ROM Program module for copying, with know-how protection Battery module for backing up the integral real-time clock (not LOGO! 24) 6AG1 057-1AA01-0BA6 J 6ED1 058-0BA02-0YA0 J 6ED1 058-0CA02-0YE0 For programming on the PC in LAD/FBD; executes on Windows 98 SE and higher, Linux, MAC OSX; on CD-ROM LOGO! manual LOGO! battery card L Programming device used to simultaneously reproduce program module contents on up to 8 program modules LOGO!Soft Comfort V6.0 4-line text display, can be connected to all LOGO! 0BA6 Basic and Pure versions, including connecting cable 6ED1 056-7DA00-0BA0 6ED1 056-6XA00-0BA0 LOGO! modem cable 6ED1 057-1AA00-0BA0 J 6ED1 057-1AA01-0BA0 6ED1 057-1CA00-0BA0 Adapter cable for analog modem communication J: Subject to export regulations AL: N and ECCN: EAR99S L: Subject to export regulations AL: 9I999 and ECCN: N 2/10 Siemens ST 70 · 2011 © Siemens AG 2011 LOGO! logic module LOGO! modular SIPLUS LOGO! modular pure versions ■ Overview • Basic versions optimized for costs • Interface for the connection of expansion modules, up to 24 digital inputs, 16 digital outputs, 8 analog inputs and 2 analog outputs can be addressed • With connection option for LOGO! text display TD (can be connected to all LOGO! 0BA6 basic versions) Note: SIPLUS extreme products are based on Siemens Industry standard products. The contents listed here were taken from the respective standard products. SIPLUS extreme-specific information was added. SIPLUS LOGO! 24o SIPLUS LOGO! 12/24RCo SIPLUS LOGO! 24RCo SIPLUS LOGO! 230RCo Order number 6AG1 052-2CC01-2BA6 6AG1 052-2MD00-2BA6 6AG1 052-2HB00-2BA6 6AG1 052-2FB00-2BA6 Order No. based on 6ED1 052-2CC01-0BA6 6ED1 052-2MD00-0BA6 6ED1 052-2HB00-0BA6 6ED1 052-2FB00-0BA6 Ambient temperature range -40 °C to +70 °C Conformal coating Coating of the printed circuit boards and the electronic components Technical data The technical data of the standard product applies except for the ambient conditions. Ambient conditions Relative humidity 5 ... 100 % Condensation permissible Biologically active substances Conformity with EN 60721-3-3, Class 3B2 mold and fungal spores (except fauna) Chemically active substances Conformity with EN 60721-3-3, Class 3C4 incl. salt mist and ISA–S71.04 severity level G1; G2; G3; GX 1) 2) Mechanically active substances Conformity with EN 60721-3-3, Class 3S4 including conductive sand, dust 2) Air pressure (depending on the highest positive temperature range specified) 1080 ... 795 hPa (-1000 ... +2000 m) see ambient temperature range 795 ... 658 hPa (+2000 ... +3500 m) derating 10 K 658 ... 540 hPa (+3500 ... +5000 m) derating 20 K 1) 2) ISA-S71.04 severity level GX: Long-term load: SO2 < 4.8 ppm; H2S < 9.9 ppm; Cl < 0.2 ppm; HCl < 0.66 ppm; HF < 0.12 ppm; NH < 49 ppm; O3 < 0.1 ppm; NOX < 5.2 ppm Limit value (max. 30 min/d): SO2 < 17.8 ppm; H2S < 49.7 ppm; Cl < 1.0 ppm; HCl < 3.3 ppm; HF < 2.4 ppm; NH < 247 ppm; O3 < 1.0 ppm; NOX < 10.4 ppm The supplied plug covers must remain in place over the unused interface when operated in atmospheres containing corrosive gases! The technical documentation on SIPLUS can be found here: www.siemens.com/siplus-extreme Siemens ST 70 · 2011 2/11 2 © Siemens AG 2011 LOGO! logic module LOGO! modular SIPLUS LOGO! modular pure versions ■ Ordering data 2 Order No. Order No. SIPLUS LOGO! 24o Accessories (extended temperature range and medial exposure) SIPLUS Upmiter upstream device I 24 V DC power supply, 8 digital inputs 24 V DC, of which 4 can be used in analog mode (0 to 10 V), 4 digital outputs 24 V DC, 0.3 A, integrated time switch; without display and keyboard; 200 function blocks can be interlinked, modular expansion capability 6AG1 052-2CC01-2BA6 L 6AG1 053-1AA00-2AA0 for reliable operation at the battery of combustion engines Additional accessories See LOGO! modular pure versions, page 2/10 SIPLUS LOGO! 12/24RCo (extended temperature range and medial exposure) 12/24 V DC power supply, 8 digital inputs 12/24 V DC, of which 4 can be used in analog mode (0 to 10 V), 4 relay outputs 10 A, integral time switch; without display and keyboard; 200 function blocks can be interlinked, modular expansion capability 6AG1 052-2MD00-2BA6 SIPLUS LOGO! 24RCo (extended temperature range and medial exposure) 24 V AC/DC power supply, 8 digital inputs 24 V AC/DC, 4 relay outputs 10 A, integral time switch; without display and keyboard; 200 function blocks can be interlinked, modular expansion capability 6AG1 052-2HB00-2BA6 SIPLUS LOGO! 230RCo (extended temperature range and medial exposure) 115/230 V AC/DC power supply, 8 digital inputs 115/230 V AC/DC, 4 relay outputs 10 A, integral time clock; without display and keyboard; 200 function blocks can be interlinked, modular expansion capability 6AG1 052-2FB00-2BA6 I: Subject to export regulations AL: N and ECCN: EAR99H L: Subject to export regulations AL: 9I999 and ECCN: N 2/12 Siemens ST 70 · 2011 © Siemens AG 2011 LOGO! logic module LOGO! modular LOGO! modular expansion modules ■ Overview • Expansion modules for the connection to LOGO! Modular • With digital inputs and outputs, analog inputs or analog outputs ■ Technical specifications Supply voltages Rated value • 12 V DC • 24 V DC • 115 V DC • 230 V DC • Permissible range, lower limit (DC) • Permissible range, upper limit (DC) • 24 V AC • 115 V AC • 230 V AC • Permissible range, lower limit (AC) • Permissible range, upper limit (AC) 6ED1 055-1CB00-0BA0 6ED1 055-1HB00-0BA0 6ED1 055-1MB00-0BA1 Yes Yes Yes Yes 6ED1 055-1FB00-0BA1 20.4 V 20.4 V 10.8 V Yes Yes 100 V 28.8 V 28.8 V 28.8 V 253 V Yes 20.4 V Yes Yes 85 V 26.4 V 265 V Digital inputs Number of digital inputs 4 4 4 4 Digital outputs Number of digital outputs 4 4; Relay 4; Relay 4; Relay Short-circuit protection Yes; electrical (1 A) No; external fusing necessary No; external fusing necessary No; external fusing necessary 3A 5A 3A 5A 3A 5A Yes Yes Yes Relay outputs Switching capacity of contacts • with inductive load, max. • with resistive load, max. • thermal continuous current, max. EMC Emission of radio interference acc. to EN 55 011 • Emission of radio interference acc. to EN 55 011 (limit value class B) 0.3 A Yes Siemens ST 70 · 2011 2/13 2 © Siemens AG 2011 LOGO! logic module LOGO! modular LOGO! modular expansion modules ■ Technical specifications (continued) 2 6ED1 055-1CB00-0BA0 6ED1 055-1HB00-0BA0 6ED1 055-1MB00-0BA1 6ED1 055-1FB00-0BA1 Environmental requirements Operating temperature • Min. • Max. 0 °C 55 °C 0 °C 55 °C 0 °C 55 °C 0 °C 55 °C Degree of protection IP20 Yes Yes Yes Yes Standards, approvals, certificates CSA approval Yes Yes Yes Yes Developed according to IEC1131 Yes Yes Yes Yes FM approval Yes Yes Yes Yes According to VDE 0631 Yes Yes Yes Yes Marine approval Yes Yes Yes Yes UL approval Yes Yes Yes Yes on 35 mm DIN rail, 2 spacing units wide 36 mm; 2 DU 90 mm 55 mm on 35 mm DIN rail, 2 spacing units wide 36 mm; 2 DU 90 mm 55 mm on 35 mm DIN rail, 2 spacing units wide 36 mm; 2 DU 90 mm 55 mm on 35 mm DIN rail, 2 spacing units wide 36 mm; 2 DU 90 mm 55 mm Dimensions and weight Dimensions • Mounting • Width • Height • Depth Supply voltages Rated value • 24 V DC • 115 V DC • 230 V DC • Permissible range, lower limit (DC) • Permissible range, upper limit (DC) • 115 V AC • 230 V AC • Permissible range, lower limit (AC) • Permissible range, upper limit (AC) • Permissible frequency range, lower limit • Permissible frequency range, upper limit 6ED1 055-1CB10-0BA0 6ED1 055-1NB10-0BA0 Yes Yes 20.4 V 28.8 V 20.4 V 28.8 V 6ED1 055-1FB10-0BA0 Yes Yes 100 V 253 V Yes Yes 85 V 265 V 47 Hz 63 Hz Digital inputs Number of digital inputs 8 8 8 Input voltage • for signal "0" • for signal "1" < 5 V DC > 12 V DC < 5 V DC > 12 V DC < 40 V AC; < 30 V DC > 79 V AC; > 79 V DC 1 mA 1 mA 0.03 mA 2 mA 2 mA 0.08 mA 1.5 ms 1.5 ms 1.5 ms 1.5 ms 50 ms 50 ms Input current • for signal "0", max. (permissible quiescent current) • for signal "1", typ. Input delay (for rated value of input voltage) • for standard inputs - at "0" to "1", max. - at "1" to "0", max. 2/14 Siemens ST 70 · 2011 © Siemens AG 2011 LOGO! logic module LOGO! modular LOGO! modular expansion modules ■ Technical specifications (continued) 6ED1 055-1CB10-0BA0 6ED1 055-1NB10-0BA0 6ED1 055-1FB10-0BA0 Digital outputs Number of digital outputs 8 8; Relay 8; Relay Short-circuit protection Yes; electrical (1 A) No; external fusing necessary external fusing necessary Lamp load, max. 2 1 000 W; 500 W at 115 V AC 1 000 W; 500 W at 115 V AC Controlling a digital input Yes Yes Yes Parallel switching of 2 outputs • for increased power No No No 10 Hz 0.5 Hz 2 Hz 0.5 Hz 10 Hz 2 Hz 0.5 Hz 10 Hz 3A 5A 3A 5A Yes Yes Yes Environmental requirements Operating temperature • Min. • Max. 0 °C 55 °C 0 °C 55 °C 0 °C 55 °C Degree of protection IP20 Yes Yes Yes Standards, approvals, certificates CSA approval Yes Yes Yes Developed according to IEC1131 Yes Yes Yes FM approval Yes Yes Yes According to VDE 0631 Yes Yes Yes Marine approval Yes Yes Yes UL approval Yes Yes Yes on 35 mm DIN rail, 4 spacing units wide 72 mm; 4 DU 90 mm 53 mm on 35 mm DIN rail, 4 spacing units wide 72 mm; 4 DU 90 mm 53 mm on DIN rail 25 mm, 4 module spaces wide 72 mm; 4 DU 90 mm 53 mm Switching frequency • with resistive load, max. • with inductive load, max. • mechanical, max. Relay outputs Switching capacity of contacts • with inductive load, max. • with resistive load, max. • thermal continuous current, max. EMC Emission of radio interference acc. to EN 55 011 • Emission of radio interference acc. to EN 55 011 (limit value class B) Dimensions and weight Dimensions • Mounting • Width • Height • Depth 0.3 A 6ED1 055-1MA00-0BA0 Supply voltages Rated value • 12 V DC • 24 V DC 6ED1 055-1MD00-0BA1 LOGO! AM2 RTD Product type designation Yes Yes Yes; 10,8 ... 28.8 V DC Yes; 10.8 ... 28.8 V DC Siemens ST 70 · 2011 2/15 © Siemens AG 2011 LOGO! logic module LOGO! modular LOGO! modular expansion modules ■ Technical specifications (continued) 2 Analog inputs Number of analog inputs Input ranges • Voltage • Current • Resistance thermometer 6ED1 055-1MA00-0BA0 6ED1 055-1MD00-0BA1 2 2; 2 or 3 wire connection Yes Yes Yes; for PT100/PT1000 sensors Input ranges (rated values), voltages • 0 to +10 V Yes Input ranges (rated values), currents • 0 to 20 mA Yes EMC Emission of radio interference acc. to EN 55 011 • Emission of radio interference acc. to EN 55 011 (limit value class B) Yes Yes; Radio interference suppression according to EN55011, limit value class B Environmental requirements Operating temperature • Min. • Max. 0 °C 55 °C 0 °C 55 °C Degree of protection IP20 Yes Yes Standards, approvals, certificates CSA approval Yes Yes; C22.2 Number 142 Developed according to IEC1131 Yes Yes; EN 61131-2 (IEC 1131-2) FM approval Yes Yes; FM-Standards No. 3611, 3600, 3810 Class I, Division 2, Group A, B, C, D According to VDE 0631 Yes Marine approval Yes Yes; ABS, BV, DNV, GL, LRS, Class NK UL approval Yes Yes; UL 508 Dimensions and weight Dimensions • Mounting • Width • Height • Depth on 35 mm DIN rail, 2 spacing units wide 36 mm 90 mm 55 mm 36 mm 90 mm 53 mm 6ED1 055-1MM00-0BA1 6ED1 055-1MM00-0BA1 Supply voltages Rated value • 12 V DC • 24 V DC No Yes Analog outputs Number of analog outputs 2 Output ranges, voltage • 0 to 10 V Yes EMC Emission of radio interference acc. to EN 55 011 • Emission of radio interference acc. to EN 55 011 (limit value class B) Environmental requirements Operating temperature • Min. • Max. 2/16 Siemens ST 70 · 2011 Yes; Radio interference suppression according to EN55011, limit value class B 0 °C 55 °C Degree of protection IP20 Yes Standards, approvals, certificates CSA approval Yes Developed according to IEC1131 Yes FM approval Yes According to VDE 0631 Yes Marine approval Yes UL approval Yes Dimensions and weight Dimensions • Mounting • Width • Height • Depth on 35 mm DIN rail, 2 spacing units wide 36 mm 90 mm 55 mm © Siemens AG 2011 LOGO! logic module LOGO! modular LOGO! modular expansion modules ■ Ordering data Order No. 6ED1 055-1CB00-0BA0 LOGO! DM8 24 Supply voltage 24 V DC, 4 digital inputs 24 V DC, 4 digital outputs 24 V DC, 0.3 A Order No. Accessories 2 LOGO! Manual LOGO! DM16 24 6ED1 055-1CB10-0BA0 Supply voltage 24 V DC, 8 digital inputs 24 V DC, 8 digital outputs 24 V DC, 0.3 A LOGO! DM8 12/24R 6ED1 055-1MB00-0BA1 Supply voltage 12/24 V DC, 4 digital inputs 12/24 V DC, 4 relay outputs 5 A LOGO! DM8 24R 6ED1 055-1HB00-0BA0 German 6ED1 050-1AA00-0AE7 English 6ED1 050-1AA00-0BE7 French 6ED1 050-1AA00-0CE7 Spanish 6ED1 050-1AA00-0DE7 Italian 6ED1 050-1AA00-0EE7 Chinese 6ED1 050-1AA00-0KE7 LOGO! memory card 6ED1 056-1DA00-0BA0 for copying, with know-how protection LOGO!Soft Comfort V6.0 Supply voltage24 V AC/DC, 4 digital inputs 24 V AC/DC, 4 relay outputs 5 A LOGO! DM16 24R 6ED1 055-1NB10-0BA0 Supply voltage 24 V DC, 8 digital inputs 24 V DC, 8 relay outputs 5 A LOGO!Soft Comfort V6.0 upgrade LOGO! DM8 230R 6ED1 055-1FB00-0BA1 6ED1 058-0BA02-0YA0 J 6ED1 058-0CA02-0YE0 Upgrade from V1.0 to V6.0 LOGO! PC cable Supply voltage 115/230 V AC/DC, 4 digital inputs 115/230 V AC/DC, 4 relay outputs 5 A J For programming on the PC in LAD/FBD; executes on Windows 98 SE and higher, Linux, MAC OSX; on CD-ROM 6ED1 057-1AA00-0BA0 For program transfer between LOGO! and PC LOGO! DM16 230R 6ED1 055-1FB10-0BA0 Supply voltage 115/230 V AC/DC, 8 digital inputs 115/230 V AC/DC, 8 relay outputs 5 A LOGO! AM2 6ED1 055-1MA00-0BA0 Supply voltage 12/24 V DC, two analog inputs 0 ... 10 V or 0 ... 20 mA, 10-bit resolution LOGO! AM2 PT 100 I 6ED1 055-1MD00-0BA1 I 6ED1 055-1MM00-0BA1 Supply voltage 12/24 V DC, 2 analog inputs Pt100, temperature range -50 °C ... 200 °C LOGO! AM2 AQ Supply voltage 24 V DC, 2 analog outputs 0 to 10 V, 0/4 to 20 mA I: Subject to export regulations AL: N and ECCN: EAR99H J: Subject to export regulations AL: N and ECCN: EAR99S Siemens ST 70 · 2011 2/17 © Siemens AG 2011 LOGO! logic module LOGO! modular SIPLUS LOGO! modular expansion modules ■ Overview • Expansion modules for connection to LOGO! Modular • With digital inputs and outputs, analog inputs, or analog outputs 2 Note: SIPLUS extreme products are based on Siemens Industry standard products. The contents listed here were taken from the respective standard products. SIPLUS extreme-specific information was added. SIPLUS LOGO! DM8 24 Order No. 6AG1 055-1CB00-2BY0 Order No. based on 6ED1 055-1CB00-0BA0 6AG1 055-1CB00-2XB0 Ambient temperature range -40 ... +70 °C Conformal coating Coating of the printed circuit boards and the electronic components Technical data The technical data of the standard product applies except for the ambient conditions. -25 ... +70 °C SIPLUS LOGO! DM8 24 Order No. 6AG1 055-1PB00-2BY0 Order No. based on 6ED1 055-1CB00-0BA0 6AG1 055-1PB00-2XB0 Ambient temperature range -40 ... +70 °C Conformal coating Coating of the printed circuit boards and the electronic components -25 ... +70 °C Technical data The technical data of the standard product applies except for the ambient conditions. SIPLUS LOGO! DM8 24 R Order Nor 6AG1 055-1HB00-2BY0 Order No. based on 6ED1 055-1HB00-0BA0 6AG1 055-1HB00-2XB0 Ambient temperature range -40 ... +70 °C Conformal coating Coating of the printed circuit boards and the electronic components Technical data The technical data of the standard product applies except for the ambient conditions. -25 ... +70 °C SIPLUS LOGO! DM8 12/24R Order No. 6AG1 055-1MB00-2BY1 Order No. based on 6ED1 055-1MB00-0BA1 Ambient temperature range -40 ... +70 °C Conformal coating Coating of the printed circuit boards and the electronic components Technical data The technical data of the standard product applies except for the ambient conditions. 2/18 Siemens ST 70 · 2011 6AG1 055-1MB00-2XB1 -25 ... +70 °C © Siemens AG 2011 LOGO! logic module LOGO! modular SIPLUS LOGO! modular expansion modules ■ Overview (continued) SIPLUS LOGO! DM8 230R Order No. 6AG1 055-1FB00-2BY1 Order No. based on 6ED1 055-1FB00-0BA1 Ambient temperature range -40 ... +70 °C Conformal coating Coating of the printed circuit boards and the electronic components Technical data The technical data of the standard product applies except for the ambient conditions. 2 6AG1 055-1FB00-2XB1 -25 ... +70 °C SIPLUS LOGO! AM2 Order number 6AG1 055-1MA00-2BY0 Order No. based on 6ED1 055-1MA00-0BA0 6AG1055-1MA00-2XB0 Ambient temperature range -40 ... +70 °C Conformal coating Coating of the printed circuit boards and the electronic components Technical data The technical data of the standard product applies except for the ambient conditions. -25 ... +70 °C SIPLUS LOGO! AM2 AQ SIPLUS LOGO! DM16 24R Order number 6AG1 055-1MM00-2BY1 6AG1 055-1NB10-2BA0 Order No. based on 6ED1 055-1MM00-0BA1 6ED1 055-1CB10-0BA0 Ambient temperature range -40 ... +70 °C -25 ... +70 °C Conformal coating Coating of the printed circuit boards and the electronic components Technical data The technical data of the standard product applies except for the ambient conditions. Ambient conditions Ambient conditions Relative humidity 5 ... 100 % Condensation permissible Biologically active substances Conformity with EN 60721-3-3, Class 3B2 mold and fungal spores (except fauna) Chemically active substances Conformity with EN 60721-3-3, Class 3C4 incl. salt mist and ISA– S71.04 severity level G1; G2; G3; GX 1 )2) Mechanically active substances Conformity with EN 60721-3-3, Class 3S4 including conductive sand, dust 2) Air pressure (depending on the highest positive temperature range specified) 1) 2) 1080 ... 795 hPa (-1000 ... +2000 m) see ambient temperature range 795 ... 658 hPa (+2000 ... +3500 m) derating 10 K 658 ... 540 hPa (+3500 ... +5000 m) derating 20 K ISA-S71.04 severity level GX: Long-term load: SO2 < 4.8 ppm; H2S < 9.9 ppm; Cl < 0.2 ppm; HCl < 0.66 ppm; HF < 0.12 ppm; NH < 49 ppm; O3 < 0.1 ppm; NOX < 5.2 ppm Limit value (max. 30 min/d): SO2 < 17.8 ppm; H2S < 49.7 ppm; Cl < 1.0 ppm; HCl < 3.3 ppm; HF < 2.4 ppm; NH < 247 ppm; O3 < 1.0 ppm; NOX < 10.4 ppm The supplied plug covers must remain in place over the unused interface when operated in atmospheres containing corrosive gases! The technical documentation on SIPLUS can be found here: www.siemens.com/siplus-extreme Siemens ST 70 · 2011 2/19 © Siemens AG 2011 LOGO! logic module LOGO! modular SIPLUS LOGO! modular expansion modules ■ Ordering data 2 Order No. Order No. SIPLUS LOGO! DM8 24 SIPLUS LOGO! AM2 (extended temperature range and medial exposure) (extended temperature range and medial exposure) 24 V DC power supply, four 24 V DC digital inputs, four 24 V DC digital outputs, 0.3 A 12/24 V DC power supply, two analog inputs 0 ... 10 V or 0 ... 20 mA, 10 bit resolution Temperature range -25 ... +70 °C H 6AG1 055-1CB00-2XB0 Temperature range -25 ... +70 °C H 6AG1 055-1MA00-2XB0 Temperature range -40 ... +70 °C L 6AG1 055-1CB00-2BY0 Temperature range -40 ... +70 °C L 6AG1 055-1MA00-2BY0 SIPLUS LOGO! DM8 12/24 SIPLUS LOGO! AM2 AQ (extended temperature range and medial exposure) (extended temperature range and medial exposure) 12/24 V DC power supply, four 12/24 V DC digital inputs, four 24 V DC digital outputs, 0.3 A 24 V DC power supply, 2x analog inputs 0 ... 10 V, 0/4 ... 20 mA, 10-bit resolution Temperature range -25 ... +70 °C L 6AG1 055-1PB00-2XB0 Temperature range -40 ... +70 °C L 6AG1 055-1MM00-2BY1 Temperature range -40 ... +70 °C L 6AG1 055-1PB00-2BY0 SIPLUS LOGO! DM16 24R SIPLUS LOGO! DM8 24R (extended temperature range and medial exposure) (extended temperature range and medial exposure) 24 V AC/DC power supply, four 24 V AC/DC digital inputs, four 5 A relay outputs Supply voltage 24 V DC, 8x digital outputs 24 V DC, 8x relay outputs 5 A Temperature range -25 ... +70 °C L 6AG1 055-1NB10-2BA0 Temperature range -25 ... +70 °C A 6AG1 055-1HB00-2XB0 Accessories Temperature range -40 ... +70 °C L 6AG1 055-1HB00-2BY0 SIPLUS Upmiter upstream device SIPLUS LOGO! DM8 12/24R (extended temperature range and medial exposure) 12/24 V DC power supply, four 12/24 V DC digital inputs, four 5 A relay outputs L 6AG1 053-1AA00-2AA0 for reliable operation at the battery of combustion engines Additional accessories See LOGO! modular pure versions, page 2/17 Temperature range -25 ... +70 °C H 6AG1 055-1MB00-2XB1 Temperature range -40 ... +70 °C L 6AG1 055-1MB00-2BY1 SIPLUS LOGO! DM8 230R (extended temperature range and medial exposure) 115/230 V AC/DC power supply, four 115/230 V AC/DC digital inputs, four 5 A relay outputs Temperature range -25 ... +70 °C A 6AG1 055-1FB00-2XB1 Temperature range -40 ... +70 °C L 6AG1 055-1FB00-2BY1 A: Subject to export regulations AL: 9I999 and ECCN: 4A994X H: Subject to export regulations AL: 9I999 and ECCN: EAR99H L: Subject to export regulations AL: 9I999 and ECCN: N 2/20 Siemens ST 70 · 2011 © Siemens AG 2011 LOGO! logic module LOGO! modular LOGO! CM EIB/KNX communication module ■ Overview ■ Technical specifications CM EIB/KNX • Expansion module for LOGO! basic versions • For communication between the LOGO! master and external EIB components through EIB 2 Supply voltage 24 V AC/DC Inputs, max. 16 DI/12 DO/8 AI/2 AO Outputs, max. 16 digital Continuous current 25 mA Short-circuit protection External fuse protection is required Integrated time switches/power reserve - Ambient temperature 0 … +55°C RI specification To EN 55 011 (limit value class B) Degree of protection IP20 Certification to VDE 0631, IEC61131-2, cULus, FM Mounting On DIN rail 35 mm, 2 module widths wide Dimensions (W x H x D) in mm 36 (2 MW) × 90 × 55 ■ Ordering data LOGO! CM EIB KNX communi- I cation module Order No. 6BK1 700-0BA00-0AA1 for connection to EIB, supply voltage 24 V DC Accessories LOGO! manual German 6ED1 050-1AA00-0AE7 English 6ED1 050-1AA00-0BE7 French 6ED1 050-1AA00-0CE7 Spanish 6ED1 050-1AA00-0DE7 Italian 6ED1 050-1AA00-0EE7 Chinese 6ED1 050-1AA00-0KE7 I: Subject to export regulations AL: N and ECCN: EAR99H Siemens ST 70 · 2011 2/21 © Siemens AG 2011 LOGO! logic module LOGO! modular AS-Interface connection for LOGO! ■ Overview 2 ■ Technical specifications Each LOGO! can now be connected to the AS-Interface system Supply oltage 24 V DC nputs outputs 4/4 (virtual inputs / outputs) AS-Interface according to specification us connection Ambient temperature 0 ... +55 °C egree of protection IP20 ounting Onto standard mounting rail imensions x x 36 x 90 x 58 mm ndications of the E s E • Green • Red • Flashes red/yellow Status No data traffic Zero address ■ Ordering data An intelligent slave can be integrated into the AS-Interface system with the AS-Interface for LOGO!. The modular interface allows the different basic units to be integrated into the system depending on the required functionality. In addition, the functionality can be quickly and simply adapted to changed requirements by replacing the basic unit. The interface provides four inputs and four outputs for the system. These I/Os, however, are not implemented in hardware, but are only virtually available via the interface. 2/22 Siemens ST 70 · 2011 AS-Interface connection for LOGO! Order No. F 3RK1 400-0CE10-0AA2 F: Subject to export regulations AL: N and ECCN: EAR99 © Siemens AG 2011 LOGO! logic module LOGO!Power LOGO!Power ■ Overview performance range are made possible by: wide-range input, radio interference class B, the extensive temperature range as well as numerous certificates. The LOGO!Power miniature power supply units from Siemens are the perfect solution for many applications – their flat, stepshaped profile makes them perfectly suited for distribution boards, for example. Even more fields of application in the lower Main product features: • 2 performance classes with 5 V, 12 V, and 15 V each • 3 performance classes with 24 V • Flat LOGO! design with an installation depth of only 55 mm • High efficiency across the entire load range • Low no-load loss • Wide-range input from 85 V to 264 V AC • Operation on DC voltage of 110 V to 300 V • Constant current for connection of loads with high inrush current • Adjustable output voltage • Green LED for "Output voltage OK" • Temperature range from -20 °C to +70 °C • Numerous certificates, such as CE, cULus, FM, GL and ATEX ■ Technical specifications LOGO!Power 5 V Power supply, type Order No. 5 V/3 A 6EP1 311-1SH03 5 V/6.3 A 6EP1 311-1SH13 Input 1-phase AC or DC 1-phase AC or DC Rated voltage Uin rated 100-240 V AC Wide-range input 100-240 V AC Wide-range input Voltage range 85 ... 264 V AC 110 … 300 V DC 85 ... 264 V AC 110 … 300 V DC Overvoltage strength 2.3 x Uin rated, 1.3 ms 2.3 x Uin rated, 1.3 ms Mains buffering at Iout rated > 40 ms at Uin = 187 V > 40 ms at Uin = 187 V Rated line frequency, rated line frequency range 50/60 Hz; 47 ... 63 Hz 50/60 Hz; 47 ... 63 Hz Rated current Iin rated 0.36-0.22 A 0.71-0.37 A Switch-on current limitation (+25 °C) < 26 A < 50 A I2 t < 0.8 A2s < 3 A2s Built-in incoming fuse Internal Internal Recommended miniature circuit breaker (IEC 898) in the mains power input 16 A or higher, Characteristic B or 10 A or higher, Characteristic C 16 A or higher, Characteristic B or 10 A or higher, Characteristic C Output Controlled, isolated DC voltage Controlled, isolated DC voltage Rated voltage Uout rated 5 V DC 5 V DC Total tolerance, static • Static line compensation • Static load compensation ±3 % Approx. 0.2% Approx. 1.5% ±3 % Approx. 0.1% Approx. 2% Residual ripple < 100 mVpp (typ. 10 mVpp) < 100 mVpp (typ. 15 mVpp) Spikes (bandwidth approx. 20 MHz) < 100 mVpp (typ. 20 mVpp) < 100 mVpp (typ. 70 mVpp) Adjustment range 4.6 ... 5.4 V 4.6 ... 5.4 V Status indicator 5 V OK = green LED 5 V OK = green LED On/Off behavior No overshoot of Uout (soft start) No overshoot of Uout (soft start) Startup delay / voltage rise < 0.5 s/typ. 15 ms < 0.5 s/typ. 10 ms Rated current Iout rated 3A 6.3 A Current range up to +55 °C • Derating 0 ... 3 A 0 ... 2.1 A (up to +70 °C) 0 ... 6.3 A 0 ... 4.4 A (up to +70 °C) Parallel switching for enhanced performance Yes, 2 units Yes, 2 units Siemens ST 70 · 2011 2/23 2 © Siemens AG 2011 LOGO! logic module LOGO!Power LOGO!Power ■ Technical specifications LOGO!Power 5 V (continued) 2 Power supply, type Order No. 5 V/3 A 6EP1 311-1SH03 5 V/6.3 A 6EP1 311-1SH13 Efficiency at Uout rated, Iout rated Approx. 77% Approx. 83% Power loss at Uout rated, Iout rated Approx. 4 W Approx. 6 W Dyn. line compensation (Uin rated ±15%) < 0.2 % Uout < 0.2 % Uout Dynamic load compensation (Iout: 10/90/10 %) Typ. ±3% Uout Typ. ±3% Uout Typ. 2 ms Typ. 2 ms Typ. 2 ms Typ. 2 ms Current limitation Typ. 3.8 A Typ. 8.2 A Short-circuit protection Constant current characteristic Constant current characteristic Sustained short-circuit current rms value <5A < 10 A Primary/secondary isolation Yes, safety extra low output voltage Uout according to EN 60950 and EN 50178 Yes, safety extra low output voltage Uout according to EN 60950 and EN 50178 Efficiency Closed-loop control Load step settling time • 10 to 90% • 90 to 10% Protection and monitoring Safety Safety class Class II (without protective conductor) Class II (without protective conductor) Safety test Yes; CB scheme Yes; CB scheme CE marking Yes Yes UL/cUL (CSA) approval cULus-listed (UL 508, CSA C22.2 No. 107.1), cURus-recognized (UL 60950, CSA C22.2 No. 60950) cULus-listed (UL 508, CSA C22.2 No. 107.1), cURus-recognized (UL 60950, CSA C22.2 No. 60950) Protection against explosion ATEX (available soon) ATEX (available soon) FM approval Class I Div. 2, Group A, B, C, D T4 Class I Div. 2, Group A, B, C, D T4 Marine approval GL (available soon) GL (available soon) Degree of protection (EN 60529) IP20 IP20 EMC Emitted interference EN 55022 Class B EN 55022 Class B Supply harmonics limitation Not applicable Not applicable Noise immunity EN 61000-6-2 EN 61000-6-2 Operating data Ambient temperature range -20 ... +70 °C with natural convection -20 ... +70 °C with natural convection Transport and storage temperature range -40 ... +85 °C -40 ... +85 °C Humidity class Climate class 3K3 according to EN 60721, no condensation Climate class 3K3 according to EN 60721, no condensation Solid/finely-stranded per screw-type terminal for 0.5 mm ... 2.5 mm2 2 screw terminals each for 0.5 ... 2.5 mm2 Solid/finely-stranded per screw-type terminal for 0.5 mm ... 2.5 mm2 2 screw terminals each for 0.5 ... 2.5 mm2 Mechanics Supply-input connections L1, N Connections • Output + • Output Dimensions (W x H x D) in mm 54 x 90 x 55 72 x 90 x 55 Weight, approx. 0.17 kg 0.25 kg Mounting Can be snapped onto standard mounting rail EN 60715 35x7.5/15 Can be snapped onto standard mounting rail EN 60715 35x7.5/15 2/24 Siemens ST 70 · 2011 © Siemens AG 2011 LOGO! logic module LOGO!Power LOGO!Power ■ Technical specifications LOGO!Power 12 V Power supply, type Order No. 12 V/1.9 A 6EP1 321-1SH03 12 V/4.5 A 6EP1 322-1SH03 Input 1-phase AC or DC 1-phase AC or DC Rated voltage value Uin rated 100-240 V AC Wide-range input 100-240 V AC Wide-range input Voltage range 85 ... 264 V AC 110 … 300 V DC 85 ... 264 V AC 110 … 300 V DC Overvoltage resistance 2.3 x Uin rated, 1.3 ms 2.3 x Uin rated, 1.3 ms Mains buffering at Iout rated > 40 ms at Uin = 187 V > 40 ms at Uin = 187 V Rated line frequency, rated line-frequency range 50/60 Hz; 47 ... 63 Hz 50/60 Hz; 47 ... 63 Hz Rated current value Iin rated 0.53-0.3 A 1.13-0.61 A Switch-on current limitation (+25 °C) < 26 A < 54 A I2 t < 0.8 A2s < 3 A2s 2 Built-in incoming fuse Internal Internal Recommended miniature circuit breaker (IEC 898) in the mains power input 16 A or higher, Characteristic B or 10 A or higher, Characteristic C 16 A or higher, Characteristic B or 10 A or higher, Characteristic C Output Controlled, isolated DC voltage Controlled, isolated DC voltage Rated voltage value Uout rated 12 V DC 12 V DC Total tolerance, static • Static mains compensation • Static load smoothing ±3 % Approx. 0.2 % Approx. 1.5 % ±3 % Approx. 0.1 % Approx. 1.5 % Residual ripple < 200 mVpp (typ. 10 mVpp) < 200 mVpp (typ. 10 mVpp) Spikes (bandwidth approx. 20 MHz) < 300 mVpp (typ. 20 mVpp) < 300 mVpp (typ. 70 mVpp) Adjustment range 10.5 ... 16.1 V 10.5 ... 16.1 V Status indicator Green LED for 12 V OK Green LED for 12 V OK On/Off behavior No overshoot of Uout (soft start) No overshoot of Uout (soft start) Startup delay / voltage rise < 0.5 s/typ. 15 ms < 0.5 s/typ. 15 ms Rated current value Iout rated 1.9 A 4.5 A Current range up to +55 °C • Derating 0 ... 1.9 A 0 ... 1.3 A (up to +70 °C) 0 ... 4.5 A 0 ... 3.1 A (up to +70 °C) Parallel switching for enhanced performance Yes, 2 units Yes, 2 units Efficiency at Uout rated, Iout rated Typ. 80 % Typ. 85 % Heat loss at Uout rated, Iout rated Typ. 5 W Typ. 10 W Dyn. mains compensation (Uin rated ±15 %) < 0.2 % Uout < 0.2 % Uout Dynamic load smoothing (Iout: 10/90/10%) Typ. ±3 % Uout Typ. ±4 % Uout Load step settling time • 10 to 90 % • 90 to 10 % Approx. 1 ms Approx. 1 ms Approx. 1 ms Approx. 1 ms Efficiency Closed-loop control Protection and monitoring Current limitation Typ. 2.8 A Typ. 5.8 A Short-circuit protection Constant current characteristic Constant current characteristic Sustained short-circuit current rms value <4A <8A Primary/secondary isolation Yes, safety extra low output voltage Uout according to EN 60950 and EN 50178 Yes, safety extra low output voltage Uout according to EN 60950 and EN 50178 Safety Protection class Class II (without protective conductor) Class II (without protective conductor) German Technical Inspectorate approval Yes; CB scheme Yes; CB scheme CE mark Yes Yes Siemens ST 70 · 2011 2/25 © Siemens AG 2011 LOGO! logic module LOGO!Power LOGO!Power ■ Technical specifications LOGO!Power 12 V (continued) 2 Power supply, type Order No. 12 V/1.9 A 6EP1 321-1SH03 12 V/4.5 A 6EP1 322-1SH03 UL/cUL (CSA) approval cULus-listed (UL 508, CSA C22.2 No. 107.1); cURus-recognized (UL 60950, CSA C22.2 No. 60950) cULus-listed (UL 508, CSA C22.2 No. 107.1); cURus-recognized (UL 60950, CSA C22.2 No. 60950) Explosion protection ATEX (available soon) ATEX (available soon) FM approval Class I Div. 2, Group A, B, C, D T4 Class I Div. 2, Group A, B, C, D T4 Marine approval GL, ABS (available soon) GL, ABS (available soon) Degree of protection (EN 60529) IP20 IP20 EMC Emitted interference EN 55022 Class B EN 55022 Class B Supply harmonics limitation Not applicable Not applicable Noise immunity EN 61000-6-2 EN 61000-6-2 Operating data Ambient temperature range -20 ... +70 °C with natural convection -20 ... +70 °C with natural convection Transport and storage temperature range -40 ... +85 °C -40 ... +85 °C Humidity class Climate class 3K3 according to EN 60721, no condensation Climate class 3K3 according to EN 60721, no condensation 1 screw terminal each for 0.5 mm ... 2.5 mm2 single-core/finely stranded 2 screw terminals each for 0.5 ... 2.5 mm2 1 screw terminal each for 0.5 mm ... 2.5 mm2 single-core/finely stranded 2 screw terminals each for 0.5 ... 2.5 mm2 Mechanics Supply-input connections L1, N Connections • Output + • Output Dimensions (W x H x D) in mm 54 x 90 x 55 72 x 90 x 55 Weight, approx. Approx. 0.17 kg Approx. 0.25 kg Installation Snaps onto standard mounting rail EN 60715 35x7.5/15 Snaps onto standard mounting rail EN 60715 35x7.5/15 Power supply, type Order No. 15 V/1.9 A 6EP1 351-1SH03 15 V/4 A 6EP1 352-1SH03 Input 1-phase AC or DC 1-phase AC or DC Rated voltage value Uin rated 100-240 V AC Wide-range input 100-240 V AC Wide-range input Voltage range 85 ... 264 V AC 110 … 300 V DC 85 ... 264 V AC 110 … 300 V DC Overvoltage resistance 2.3 x Uin rated, 1.3 ms 2.3 x Uin rated, 1.3 ms Mains buffering at Iout rated > 40 ms at Uin = 187 V > 40 ms at Uin = 187 V ■ Technical specifications LOGO!Power 15 V Rated line frequency, rated line-frequency range 50/60 Hz; 47 ... 63 Hz 50/60 Hz; 47 ... 63 Hz Rated current value Iin rated 0.63-0.33 A 1.24-0.68 A Switch-on current limit (+25 °C) < 26 A < 54 A I2 t < 0.8 A2s < 3 A2s Built-in incoming fuse Internal Internal Recommended miniature circuit breaker (IEC 898) in the mains power input 16 A or higher, Characteristic B or 10 A or higher, Characteristic C 16 A or higher, Characteristic B or 10 A or higher, Characteristic C Output Controlled, isolated DC voltage Controlled, isolated DC voltage Rated voltage Uout rated 15 V DC 15 V DC Total tolerance, static • Static mains compensation • Static load smoothing ±3 % Approx. 0.1 % Approx. 1.5 % ±3 % Approx. 0.1 % Approx. 1.5 % Residual ripple < 200 mVpp (typ. 10 mVpp) < 200 mVpp (typ. 10 mVpp) 2/26 Siemens ST 70 · 2011 © Siemens AG 2011 LOGO! logic module LOGO!Power LOGO!Power ■ Technical specifications LOGO!Power 15 V (continued) Power supply, type Order No. 15 V/1.9 A 6EP1 351-1SH03 15 V/4 A 6EP1 352-1SH03 Spikes (bandwidth approx. 20 MHz) < 300 mVpp (typ. 30 mVpp) < 300 mVpp (typ. 70 mVpp) Adjustment range 10.5 ... 16.1 V 10.5 ... 16.1 V Status indicator Green LED for 15 V OK Green LED for 15 V OK On/Off behavior No overshoot of Uout (soft start) No overshoot of Uout (soft start) Startup delay / voltage rise < 0.5 s/typ. 15 ms < 0.5 s/typ. 15 ms Rated current value Iin rated 1.9 A 4A Current range up to +55 °C • Derating 0 ... 1.9 A 0 ... 1.3 A (up to +70 °C) 0 ... 4 A 0 ... 2.8 A (up to +70 °C) Parallel switching for enhanced performance Yes, 2 units Yes, 2 units Efficiency at Uout rated, Iout rated Approx. 81 % Approx. 85 % Heat loss at Uout rated, Iout rated Approx. 7 W Approx. 11 W Dyn. mains compensation (Uin rated ±15%) < 0.2 % Uout < 0,2 % Uout Dynamic load smoothing (Iout: 10/90/10%) Typ. ±2.8 % Uout Typ. ±3 % Uout Typ. 1 ms Typ. 1 ms Typ. 1 ms Typ. 1 ms 2 Efficiency Closed-loop control Load step settling time • 10 to 90 % • 90 to 10 % Protection and monitoring Current limitation Typ. 2.7 A Typ. 5.7 A Short-circuit protection Constant current characteristic Constant current characteristic Sustained short-circuit current rms value <4A <8A Primary/secondary isolation Yes, safety extra low output voltage Uout according to EN 60950 and EN 50178 Yes, safety extra low output voltage Uout according to EN 60950 and EN 50178 Safety Protection class Class II (without protective conductor) Class II (without protective conductor) Safety test Yes; CB scheme Yes; CB scheme CE mark Yes Yes UL/cUL (CSA) approval cULus-listed (UL 508, CSA C22.2 No. 107.1); cURus-recognized (UL 60950, CSA C22.2 No. 60950) cULus-listed (UL 508, CSA C22.2 No. 107.1); cURus-recognized (UL 60950, CSA C22.2 No. 60950) Explosion protection ATEX (available soon) ATEX (available soon) FM approval Class I Div. 2, Group A, B, C, D T4 Class I Div. 2, Group A, B, C, D T4 Marine approval GL (available soon) GL (available soon) Degree of protection (EN 60529) IP20 IP20 Emitted interference EN 55022 Class B EN 55022 Class B Supply harmonics limitation Not applicable Not applicable Noise immunity EN 61000-6-2 EN 61000-6-2 EMC Operating data Ambient temperature range -20 ... +70 °C with natural convection -20 ... +70 °C with natural convection Transport and storage temperature range -40 ... +85 °C -40 ... +85 °C Humidity class Climate class 3K3 according to EN 60721, no condensation Climate class 3K3 according to EN 60721, no condensation Siemens ST 70 · 2011 2/27 © Siemens AG 2011 LOGO! logic module LOGO!Power LOGO!Power ■ Technical specifications LOGO!Power 15 V (continued) 2 Power supply, type Order No. 15 V/1.9 A 6EP1 351-1SH03 15 V/4 A 6EP1 352-1SH03 1 screw terminal each for 0.5 mm ... 2.5 mm2 single-core/finely stranded 2 screw terminals each for 0.5 ... 2.5 mm2 1 screw terminal each for 0.5 mm ... 2.5 mm2 single-core/finely stranded 2 screw terminals each for 0.5 ... 2.5 mm2 Mechanics Supply-input connections L1, N Connections • Output + • Output Dimensions (W x H x D) in mm 54 x 90 x 55 72 x 90 x 55 Weight, approx. Approx. 0.17 kg Approx. 0.25 kg Installation Snaps onto standard mounting rail EN 60715 35x7.5/15 Snaps onto standard mounting rail EN 60715 35x7.5/15 ■ Technical specifications LOGO!Power 24 V/1.3 A Power supply, type Order No. 24 V/1.3 A 6EP1 331-1SH03 Power supply, type Order No. 24 V/1.3 A 6EP1 331-1SH03 Input 1-phase AC or DC Closed-loop control Rated voltage Uin rated 100-240 V AC Wide-range input Dyn. mains compensation (Uin rated ±15%) < 0,2 % Uout Voltage range 85 ... 264 V AC 110 … 300 V DC Dynamic load smoothing (Iout: 50/100/50 %) Typ. ±1% Uout (Iout: 10/90/10 %) Overvoltage strength 2.3 x Uin rated, 1.3 ms Mains buffering at Iout rated > 40 ms at Uin = 187 V Load step settling time • 50 to 100% • 100 to 50% Typ. 1 ms (10 to 90%) Typ. 1 ms (90 to 10%) Rated line frequency, rated line-frequency range 50/60 Hz; 47 ... 63 Hz Rated current Iin rated 0.7-0.35 A Switch-on current limitation (+25 °C) I2 t Built-in incoming fuse Internal Recommended miniature circuit breaker (IEC 898) in the mains power input 16 A or higher, Characteristic B or 10 A or higher, Characteristic C Protection and monitoring Output overvoltage protection Yes, according to EN 60950 < 30 A Current limitation Typ. 1.7 A < 0.8 A2s Short-circuit protection Constant current characteristic Sustained short-circuit current rms value <4A Overload/short-circuit indicator - Output Controlled, isolated DC voltage Rated voltage Uout rated 24 V DC Total tolerance • Static mains compensation • Static load smoothing ±3 % Approx. 0.1% Approx. 1.5% Residual ripple < 200 mVpp (typ. 10 mVpp) Spikes (bandwidth approx. 20 MHz) Safety Primary/secondary isolation Yes, safety extra low output voltage Uout according to EN 60950-1 and EN 50178 Safety class Class II (without protective conductor) Leakage current - Safety test Yes; CB scheme < 300 mVpp (typ. 20 mVpp) CE marking Yes Adjustment range 22.2 ... 26.4 V UL/cUL (CSA) approval Status indicator 24 V OK = green LED On/Off behavior No overshoot of Uout (soft start) cULus-listed (UL 508, CSA C22.2 No. 107.1), cURusrecognized (UL 60950, CSA C22.2 No. 60950) Startup delay / voltage rise < 0.5 s/typ. 15 ms Protection against explosion ATEX EX II 3G Ex nA IIC T3 FM approval Rated current Iout rated 1.3 A Class I Div. 2, Group A, B, C, D T4 Marine approval GL, ABS 0 ... 1.3 A (up to +55°C) 0 ... 0.9 A (up to +70°C) Degree of protection (EN 60529) IP20 Yes, 2 units Emitted interference EN 55022 Class B Supply harmonics limitation Not applicable Noise immunity EN 61000-6-2 Current range • Current range up to +60 °C • Derating Parallel switching for enhanced performance Efficiency Efficiency at Uout rated, Iout rated Approx. 83% Power loss at Uout rated, Iout rated Approx. 6.3 W 2/28 Siemens ST 70 · 2011 EMC © Siemens AG 2011 LOGO! logic module LOGO!Power LOGO!Power ■ Technical specifications LOGO!Power 24 V/1.3 A (continued) Power supply, type Order No. 24 V/1.3 A 6EP1 331-1SH03 Operating data Ambient temperature range -20 ... +70 °C with natural convection Transport and storage temperature range -40 ... +85 °C Humidity class Climate class 3K3 according to EN 60721, no condensation Power supply, type Order No. 24 V/1.3 A 6EP1 331-1SH03 Dimensions (W x H x D) in mm 54 x 90 x 55 Weight, approx. Approx. 0.17 kg Mounting Can be snapped onto standard mounting rail EN 60715 35x7.5/15 Accessories - 24 V/2.5 A 6EP1 332-1SH43 2 Mechanics Connections • Supply input L, N, PE DC input: L+1, M1, PE • Output + • Output - Solid/finely-stranded per screw-type terminal (L, N) for 0.5 mm ... 2.5 mm2 2 screw-type terminals for 0.5 ... 2.5 mm2 2 screw-type terminals for 0.5 ... 2.5 mm2 ■ Technical specifications LOGO!Power 24 V/2.5 A Power supply, type Order No 24 V/2.5 A 6EP1 332-1SH43 Power supply, type Order No Input 1-phase AC or DC Efficiency Rated voltage Uin rated 100-240 V AC Wide-range input Efficiency at Uout rated, Iout rated Approx. 88% Power loss at Uout rated, Iout rated Approx. 8 W Voltage range 85 ... 264 V AC 110 … 300 V DC Closed-loop control Overvoltage strength 2.3 x Uin rated, 1.3 ms Mains buffering at Iout rated > 40 ms at Uin = 187 V Rated line frequency, rated line-frequency range 50/60 Hz; 47 ... 63 Hz Rated current Iin rated 1.22-0.66 A Switch-on current limitation (+25 °C) < 46 A I2 t < 3 A 2s Built-in incoming fuse Internal Recommended miniature circuit breaker (IEC 898) in the mains power input 16 A or higher, Characteristic B or 10 A or higher, Characteristic C Output Dyn. mains compensation (Uin rated ±15%) < 0,2 % Uout Dynamic load smoothing (Iout: 50/100/50 %) Typ. ±2% Uout (Iout: 10/90/10 %) Load step settling time • 50 to 100% • 100 to 50% Typ. 1 ms (10 to 90%) Typ. 1 ms (90 to 10%) Protection and monitoring Output overvoltage protection Yes, according to EN 60950 Current limitation Typ. 3.3 A Short-circuit protection Controlled, isolated DC voltage Constant current characteristic Sustained short-circuit current rms value Approx. 3.5 A Rated voltage Uout rated 24 V DC Safety Total tolerance • Static mains compensation • Static load smoothing ±3 % Approx. 0.1% Approx. 1.5% Primary/secondary isolation Yes, safety extra low output voltage Uout according to EN 60950-1 and EN 50178 Residual ripple < 200 mVpp (typ. 10 mVpp) Safety class Class II (without protective conductor) Spikes (bandwidth approx. 20 MHz) < 300 mVpp (typ. 50 mVpp) Leakage current - Adjustment range 22.2 ... 26.4 V Safety test Yes; CB scheme Status indicator 24 V OK = green LED CE marking Yes On/Off behavior No overshoot of Uout (soft start) UL/cUL (CSA) approval Startup delay / voltage rise < 0.5 s/typ. 10 ms cULus-listed (UL 508, CSA C22.2 No. 107.1), cURusrecognized (UL 60950, CSA C22.2 No. 60950) Rated current Iout rated 2.5 A Protection against explosion ATEX EX II 3G Ex nA IIC T3 FM approval 0 ... 2.5 A (up to +55°C) 0 ... 1.75 A (up to +70°C) Class I Div. 2, Group A, B, C, D T4 Marine approval GL, ABS Yes, 2 units Degree of protection (EN 60529) IP20 Current range • Current range up to +60 °C • Derating Parallel switching for enhanced performance Siemens ST 70 · 2011 2/29 © Siemens AG 2011 LOGO! logic module LOGO!Power LOGO!Power ■ Technical specifications LOGO!Power 24 V/2.5 A (continued) 2 Power supply, type Order No 24 V/2.5 A 6EP1 332-1SH43 EMC Power supply, type Order No 24 V/2.5 A 6EP1 332-1SH43 Mechanics Emitted interference EN 55022 Class B Supply harmonics limitation Not applicable Noise immunity EN 61000-6-2 Connections • Supply input L, N, PE DC input: L+1, M1, PE • Output + Operating data Solid/finely-stranded per screw-type terminal (L, N) for 0.5 mm ... 2.5 mm2 2 screw-type terminals for 0.5 ... 2.5 mm2 2 screw-type terminals for 0.5 ... 2.5 mm2 Ambient temperature range -20 ... +55 °C with natural convection • Output - Transport and storage temperature range -40 ... +70 °C Dimensions (W x H x D) in mm 72 x 90 x 55 Humidity class Climate class 3K3 according to EN 60721, no condensation Weight, approx. Approx. 0.25 kg Mounting Can be snapped onto standard mounting rail EN 60715 35x7.5/15 Accessories - ■ Technical specifications LOGO!Power 24 V/4 A Power supply, type Order No. 24 V/4 A 6EP1 332-1SH52 Power supply, type Order No. 24 V/4 A 6EP1 332-1SH52 Input 1-phase AC or DC Rated current Iout rated 4A Rated voltage Uin rated 100-240 V AC Wide-range input Voltage range 85 ... 264 V AC 110 … 300 V DC Current range • Current range up to +60 °C • Derating 0 ... 4 A (up to +55°C) 0 ... 2.8 A (up to +70°C) Overvoltage strength 2.3 x Uin rated, 1.3 ms Mains buffering at Iout rated > 40 ms at Uin = 187 V Rated line frequency, rated line-frequency range 50/60 Hz; 47 ... 63 Hz Parallel switching for enhanced performance Yes, 2 units Efficiency Efficiency at Uout rated, Iout rated Approx. 89% Power loss at Uout rated, Iout rated Approx. 12 W Rated current Iin rated 1.95 to 0.97 A Closed-loop control Switch-on current limitation (+25 °C) < 30 A Dyn. mains compensation (Uin rated ±15%) < 0,2 % Uout I 2t < 2.5 A 2s Built-in incoming fuse Internal Dynamic load smoothing (Iout: 50/100/50 %) Typ. ±1.5% Uout (Iout: 10/90/10 %) Recommended miniature circuit breaker (IEC 898) in the mains power input 16 A or higher, Characteristic B or 10 A or higher, Characteristic C Load step settling time • 50 to 100% • 100 to 50% Typ. 1 ms (10 to 90%) Typ. 1 ms (90 to 10%) Output Controlled, isolated DC voltage Protection and monitoring Rated voltage Uout rated 24 V DC Output overvoltage protection Yes, according to EN 60950 Total tolerance • Static mains compensation • Static load smoothing ±3 % Approx. 0.1% Approx. 1.5% Current limitation Typ. 5.2 A Short-circuit protection Constant current characteristic Sustained short-circuit current rms value < 10 A Overload/short-circuit indicator - Residual ripple < 200 mVpp (typ. 30 mVpp) Spikes (bandwidth approx. 20 MHz) < 300 mVpp (typ. 60 mVpp) Adjustment range 22.2 ... 26.4 V Status indicator 24 V OK = green LED On/Off behavior No overshoot of Uout (soft start) Startup delay / voltage rise < 0.5 s/typ. 15 ms 2/30 Siemens ST 70 · 2011 Safety Primary/secondary isolation Yes, safety extra low output voltage Uout according to EN 60950-1 and EN 50178 Safety class Class II (without protective conductor) © Siemens AG 2011 LOGO! logic module LOGO!Power LOGO!Power ■ Technical specifications LOGO!Power 24 V/4 A (continued) Power supply, type Order No. 24 V/4 A 6EP1 332-1SH52 Power supply, type Order No. Leakage current - Operating data Safety test Yes; CB scheme Ambient temperature range CE marking Yes -20 ... +70 °C with natural convection UL/cUL (CSA) approval cULus-listed (UL 508, CSA C22.2 No. 107.1), cURus-recognized (UL 60950, CSA C22.2 No. 60950) Transport and storage temperature range -40 ... +85 °C Humidity class Climate class 3K3 according to EN 60721, no condensation Protection against explosion ATEX EX II 3G Ex nA IIC T3 FM approval Class I Div. 2, Group A, B, C, D T4 Marine approval GL, ABS Degree of protection (EN 60529) IP20 Emitted interference EN 55022 Class B Supply harmonics limitation EN 61000-3-2 Noise immunity EN 61000-6-2 2 Mechanics Connections • Supply input L, N, PE DC input: L+1, M1, PE • Output + • Output - EMC 24 V/4 A 6EP1 332-1SH52 Solid/finely-stranded per screw-type terminal (L, N) for 0.5 mm ... 2.5 mm2 2 screw terminals each for 0.5 ... 2.5 mm2 2 screw terminals each for 0.5 ... 2.5 mm2 Dimensions (W x H x D) in mm 90 x 90 x 55 Weight, approx. Approx. 0.34 kg Mounting Can be snapped onto standard mounting rail EN 60715 35x7.5/15 Accessories - Siemens ST 70 · 2011 2/31 © Siemens AG 2011 LOGO! logic module LOGO!Power LOGO!Power ■ Ordering data 2 Order No. Order No. LOGO!Power 5 V LOGO!Power 24 V/1.3 A Stabilized power supply; Output: 5 V DC/3 A • Input: 110 … 300 V AC; extended operating temperature range: up to +70°C Stabilized power supply; Output: 24 V DC/1.3 A • Input: 110 … 300 V AC; extended operating temperature range: up to +70°C Stabilized power supply; Output: 5 V DC/6.3 A • Input: 110 … 300 V AC; extended operating temperature range: up to +70°C 6EP1 311-1SH03 LOGO!Power 24 V/2.5 A 6EP1 311-1SH13 LOGO!Power 12 V 6EP1 321-1SH03 Stabilized power supply; Output: 12 V DC/4.5 A • Input: 110 … 300 V AC; extended operating temperature range: up to +70°C 6EP1 322-1SH03 LOGO!Power 15 V Stabilized power supply; Output: 15 V DC/1.9 A • Input: 110 … 300 V AC; extended operating temperature range: up to +70°C 6EP1 351-1SH03 Stabilized power supply; Output: 15 V DC/4 A • Input: 110 … 300 V AC; extended operating temperature range: up to +70°C 6EP1 352-1SH03 ■ More information In addition to various power supply product lines, the perfectly coordinated complete SITOP range offers a unique range of add-on modules with which the 24 V power supply can be additionally protected against interference on the primary and secondary side – right up to all-round protection: • Redundancy module for setting up a redundant power supply • Uninterruptible 24 V power supplies with batteries or maintenance-free capacitors for continued operation in the event of a power failure • Selectivity modules for electronic protection of 24 V branches from overload and short-circuit You can find more information in Catalog KT 10.1 and in the Internet at www.siemens.com/sitop Siemens ST 70 · 2011 Stabilized power supply; Output: 24 V DC/2.5 A • Input: 110 … 300 V AC; extended operating temperature range: up to +70°C 6EP1 332-1SH43 LOGO!Power 24 V/4 A Stabilized power supply; Output: 12 V DC/1.9 A • Input: 110 … 300 V AC; extended operating temperature range: up to +70°C 2/32 6EP1 331-1SH03 Stabilized power supply; Output: 24 V DC/4 A • Input: 110 … 300 V AC; extended operating temperature range: up to +70°C 6EP1 332-1SH52 © Siemens AG 2011 LOGO! logic module LOGO!Power SIPLUS LOGO!Power ■ Overview ■ Technical specifications Note: Power supply, type 24 V/1.3 A SIPLUS extreme products are based on Siemens Industry standard products. The contents listed here were taken from the respective standard products. SIPLUS extreme-specific information was added. Order number 6EP1 331-1SH02 Input 1-phase AC Rated voltage Uin rated 100 ... 240 V AC Wide-range input Voltage range 85 ... 264 V AC Overvoltage strength 2.3 x Uin rated, 1.3 ms SIPLUS LOGO!Power 1.3 A Order number 6AG1 931-1SH02-2AA0 Mains buffering at Iout rated > 40 ms at Uin = 187 V Order No. based on 6EP1 331-1SH02 50/60 Hz; 47 ... 63 Hz Ambient temperature range -25 °C to +70 °C Rated line frequency, rated line frequency range Conformal coating Coating of the printed circuit boards and the electronic components Rated current Iin rated 0.7-0.35 A Technical data The technical data of the standard product applies except for the ambient conditions. Ambient conditions Relative humidity 5 ... 100 % Condensation permissible Biologically active substances Conformity with EN 60721-3-3, Class 3B2 mold and fungal spores (except fauna) Chemically active substances Mechanically active substances Air pressure (depending on the highest positive temperature range specified) 1) 2) Conformity with EN 60721-3-3, Class 3C4 incl. salt mist and ISA– S71.04 severity level G1; G2; G3; GX 1) 2) Conformity with EN 60721-3-3, Class 3S4 including conductive sand, dust 2) 1080 ... 795 hPa (-1000 ... +2000 m) see ambient temperature range 795 ... 658 hPa (+2000 ... +3500 m) derating 10 K 658 ... 540 hPa (+3500 ... +5000 m) derating 20 K ISA-S71.04 severity level GX: Long-term load: SO2 < 4.8 ppm; H2S < 9.9 ppm; Cl < 0.2 ppm; HCl < 0.66 ppm; HF < 0.12 ppm; NH < 49 ppm; O3 < 0.1 ppm; NOX < 5.2 ppm Threshold / limit value (max. 30 min/d): SO2 < 17.8 ppm; H2S < 49.7 ppm; Cl < 1.0 ppm; HCl < 3.3 ppm; HF < 2.4 ppm; NH < 247 ppm; O3 < 1.0 ppm; NOX < 10.4 ppm The supplied plug covers must remain in place over the unused interface when operated in atmospheres containing corrosive gases! 2 Switch-on current limitation (+25 °C) < 35 A I2t < 0.8 A2s Built-in incoming fuse Internal Recommended miniature circuit breaker (IEC 898) in the mains power input 16 A or higher, Characteristic B or 10 A or higher, Characteristic C Output Controlled, isolated DC voltage Rated voltage Uout rated 24 V DC Total tolerance • Static mains compensation • Static load smoothing ±3 % Approx. 0.1% Approx. 1.5% Residual ripple < 200 mVpp (typ. 10 mVpp) Spikes (bandwidth approx. 20 MHz) < 300 mVpp (typ. 20 mVpp) Setting range 22.2 ... 26.4 V Status indicator 24 V OK = green LED On/Off behavior No overshoot of Uout (soft start) Startup delay / voltage rise < 0.5 s/typ. 15 ms Rated current Iout rated 1.3 A Current range • Current range up to +60 °C • Derating 0 ... 1.3 A (up to 55 °C) - Parallel switching for enhanced performance Yes, 2 units Efficiency Efficiency at Uout rated, Iout rated Approx. 82% Heat loss at Uout rated, Iout rated Approx. 7 W Closed-loop control The technical documentation on SIPLUS can be found here: Dyn. mains compensation (Uin rated ±15%) < 0,2 % Uout www.siemens.com/siplus-extreme Dynamic load smoothing (Iout: 50/100/50 %) Typ. ±1.5 % Uout (Iout: 10/90/10 %) Load step settling time • 50 to 100% • 100 to 50% Typ. 20 ms (10 to 90%) Typ. 20 ms (90 to 10%) Protection and monitoring Output overvoltage protection Yes, according to EN 60950 Current limitation Typ. 2 A Short-circuit protection Constant current characteristic Sustained short-circuit current rms value <4A Overload/short-circuit indicator - Siemens ST 70 · 2011 2/33 © Siemens AG 2011 LOGO! logic module LOGO!Power SIPLUS LOGO!Power ■ Technical specifications (continued) Power supply, type 2 24 V/1.3 A Safety Primary/secondary isolation ■ Ordering data SIPLUS LOGO!Power 24 V 1.3 A L Order No. 6AG1 931-1SH02-2AA0 (extended temperature range and medial exposure) Yes, safety extra low output voltage Uout according to EN 60950 and EN 50178 Input 100 ... 240 V AC Output 24 V DC, 1.3 A Protection class Class II (without protective conductor) L: Subject to export regulations AL: 9I999 and ECCN: N Leakage current - Safety test Yes; CB scheme CE marking Yes UL/cUL (CSA) approval cULus-listed (UL 508, CSA C22.2 No. 107.1), File E197259; cURusrecognized (UL 60950, CSA C22.2 No. 60950), File E151273 Explosion protection ATEX EX II 3G Ex nA IIC T3 FM approval Class I Div. 2, Group A, B, C, D T4 Marine approval GL, ABS Degree of protection (EN 60529) IP20 EMC Emitted interference EN 55022 Class B Supply harmonics limitation Not applicable Noise immunity EN 61000-6-2 Operating data Range of ambient temperature -20 ... +55 °C with natural convection Transport and storage temperature range -40 ... +70 °C Humidity class Climate class 3K3 according to EN 60721, no condensation Mechanics Connections • Supply input L, N, PE DC input: L+1, M1, PE • Output + • Output - One solid/finely-stranded screwtype terminal each (L, N) for 0.5 mm ... 2.5 mm2 2 screw-type terminals for 0.5 ... 2.5 mm2 2 screw-type terminals for 0.5 ... 2.5 mm2 Dimensions (W x H x D) in mm 54 x 90 x 55 Weight, approx. Approx. 0.17 kg Installation Can be snapped onto standard mounting rail EN 60715 35x7.5/15 Accessories - 2/34 Siemens ST 70 · 2011 © Siemens AG 2011 LOGO! logic module LOGO!Contact LOGO!Contact ■ Overview ■ Technical specifications Dimensions and weight Weight • Weight, approx. 6ED1 057-4CA000AA0 6ED1 057-4EA000AA0 160 g 160 g ■ Ordering data Order No. LOGO!Contact Switching module for direct switching of resistive loads up to 20 A and motors up to 4 kW Switching voltage 24 V 6ED1 057-4CA00-0AA0 Switching voltage 230 V 6ED1 057-4EA00-0AA0 • Switching module for the direct switching of resistive loads and motors Siemens ST 70 · 2011 2/35 2 © Siemens AG 2011 LOGO! logic module LOGO! software LOGO! software ■ Overview ■ Ordering data LOGO!Soft Comfort V6.0 2 Order No. J 6ED1 058-0BA02-0YA0 J 6ED1 058-0CA02-0YE0 For programming on the PC in LAD/FBD; executes under Windows 98 SE and higher, Linux, MAC OSX; on CD-ROM LOGO!Soft Comfort V6.0 upgrade Upgrade from V1.0 to V6.0 J: Subject to export regulations AL: N and ECCN: EAR99S • The user-friendly software for creating control programs on a PC • Creation of control programs in Function Block Diagram (FBD) or Ladder Diagram (LAD) • Plus testing, simulation, online testing and archiving of control programs • Professional documentation via numerous comment and print functions The connection between LOGO! and the PC is made using the LOGO! PC cable (serial interface) or the LOGO! USB PC cable (USB interface). Minimum system requirements Windows 98 SE, NT 4.0, ME, 2000, XP or Vista (not 64 bit) • PC Pentium. • 90 MB free disk capacity. • 64 MB RAM. • SVGA graphics card with minimum resolution 800x600 (256 colors). Mac OS X • PowerMac G3, G4, G4 Cube, IMac, PowerBook G3, G4 or iBook. Linux (tested with Caldera OpenLinux 2.4) • Runs on all Linux distributions on which the Java 2 SDK Version 1.3.1 runs. • Please refer to your relevant Linux distribution for the necessary hardware requirements. ■ 2/36 Siemens ST 70 · 2011
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement