VMware 5.6 vCloud Director Installation and Upgrade Guide

VMware 5.6 vCloud Director Installation and Upgrade Guide

vCloud Director 5.6 helps you install or upgrade VMware vCloud Director software and configure it to work with VMware vCenter to provide VMware-ready VMware vCloud services.

advertisement

Assistant Bot

Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.

VMware vCloud Director 5.6 Installation and Upgrade Guide | Manualzz

vCloud Director Installation and

Upgrade Guide

vCloud Director 5.6

This document supports the version of each product listed and supports all subsequent versions until the document is replaced by a new edition. To check for more recent editions of this document, see http://www.vmware.com/support/pubs .

EN-001288-01

vCloud Director Installation and Upgrade Guide

You can find the most up-to-date technical documentation on the VMware Web site at: http://www.vmware.com/support/

The VMware Web site also provides the latest product updates.

If you have comments about this documentation, submit your feedback to: [email protected]

Copyright

©

2010–2014 VMware, Inc. All rights reserved.

Copyright and trademark information

.

VMware, Inc.

3401 Hillview Ave.

Palo Alto, CA 94304 www.vmware.com

2 VMware, Inc.

Contents

VMware vCloud Director Installation and Upgrade Guide 5

1

Overview of vCloud Director Installation, Configuration, and Upgrade 7

vCloud Director Architecture 7

Configuration Planning 8

vCloud Director Hardware and Software Requirements 9

2

Creating a vCloud Director Server Group 27

Install and Configure vCloud Director Software on the First Member of a Server Group 28

Configure Network and Database Connections 30

Install vCloud Director Software on Additional Members of a Server Group 34

Install Microsoft Sysprep Files on the Servers 35

Start or Stop vCloud Director Services 36

Uninstall vCloud Director Software 37

3

Upgrading vCloud Director 39

Use the Cell Management Tool to Quiesce and Shut Down a Server 41

Upgrade vCloud Director Software on Any Member of a Server Group 43

Upgrade the vCloud Director Database 45

Upgrade the Existing vShield Manager or NSX Manager That Is Associated with an Attached vCenter Server System 47

Upgrade vCenter Server Systems, Hosts, and vShield Edge Appliances 48

4

vCloud Director Setup 51

Review the License Agreement 52

Enter the License Key 52

Create the System Administrator Account 52

Specify System Settings 52

Ready to Log In to vCloud Director 53

5

Cell Management Tool Reference 55

Managing a Cell 56

Exporting Database Tables 57

Detecting and Repairing Corrupted Scheduler Data 60

Replacing SSL Certificates 60

Generating Self-Signed SSL Certificates 61

Managing the List of Allowed SSL Ciphers 62

Configuring the Metrics Database Connection 64

Recovering the System Administrator Password 65

Force Running Tasks to Complete 65

VMware, Inc. 3

vCloud Director Installation and Upgrade Guide

6

Install and Configure Optional Database Software to Store and Retrieve

Historic Virtual Machine Performance Metrics 67

Index 69

4 VMware, Inc.

VMware vCloud Director Installation and

Upgrade Guide

The VMware vCloud Director Installation and Upgrade Guide provides information about installing or upgrading VMware

®

vCloud Director

®

software and configuring it to work with VMware vCenter™ to provide VMware-ready VMware vCloud

®

services.

Intended Audience

The VMware vCloud Director Installation and Upgrade Guide is intended for anyone who wants to install or upgrade VMware vCloud Director software. The information in this book is written for experienced system administrators who are familiar with Linux, Windows, IP networks, and VMware vSphere

®

.

VMware, Inc. 5

vCloud Director Installation and Upgrade Guide

6 VMware, Inc.

Overview of vCloud Director

Installation, Configuration, and

Upgrade

1

A VMware vCloud

®

combines a vCloud Director server group with the vSphere platform. You create a vCloud Director server group by installing vCloud Director software on one or more servers, connecting the servers to a shared database, and integrating the vCloud Director server group with vSphere.

The initial configuration of vCloud Director, including database and network connection details, is established during installation. When you upgrade an existing installation to a new version of vCloud Director, you update the vCloud Director software and database schema, leaving the existing relationships between servers, the database, and vSphere in place.

This chapter includes the following topics: n

“vCloud Director Architecture,” on page 7

n n

“Configuration Planning,” on page 8

“vCloud Director Hardware and Software Requirements,” on page 9

vCloud Director Architecture

A vCloud Director server group consists of one or more vCloud Director servers. These servers share a common database, and are linked to an arbitrary number of vCenter Server systems and ESXi hosts.

Network services are provided to the vCenter Server systems and vCloud Director by the VMware vShield

Manager™ component from VMware vCloud

®

Networking and Security™ or by the VMware NSX

Manager™ component from VMware NSX™ for vSphere

®

.

A typical installation creates a vCloud Director server group comprising several servers. Each server in the group runs a collection of services called a vCloud Director cell. All members of the group share a single database. Each cell in the group connects to multiple vCenter Server systems, the hosts that they manage, and each vShield Manager or NSX Manager that is configured to support each connected vCenter Server system.

VMware, Inc. 7

vCloud Director Installation and Upgrade Guide

Figure 1

1. vCloud Director Architecture Diagram for an Installation That Uses vShield Manager vCloud Director Installation vCloud Director

Database vCloud Director

Server

Cell

ESX/ESXi

ESX/ESXi vCenter

VMware vCloud Director

VMware vSphere vShield

Manager

vCenter

Database

The vCloud Director installation and configuration process creates the cells, connects them to the shared database, and establishes the first connections to a vCenter Server system, that vCenter Server system's associated vShield Manager or NSX Manager, and its hosts. A system administrator can then use the vCloud Director Web Console to add vCenter Server systems, the vShield Manager or NSX Manager associated with the added vCenter Server system, and the added vCenter Server system's hosts to the vCloud Director server group at any time.

Configuration Planning

vSphere provides storage, compute, and networking capacity to vCloud Director. Before you begin installation, consider how much vSphere and vCloud Director capacity you need, and plan a configuration that can support it.

Configuration requirements depend on many factors, including the number of organizations in the cloud, the number of users in each organization, and the activity level of those users. The following guidelines can serve as a starting point for most configurations: n n n

Allocate one vCloud Director server (cell) for each vCenter Server system that you want to make accessible in your cloud.

Be sure that all vCloud Director servers meet at least the minimum requirements for memory and

storage detailed in “vCloud Director Hardware and Software Requirements,” on page 9.

Configure the vCloud Director database as described in

“Installing and Configuring a vCloud Director

Database,” on page 15.

8 VMware, Inc.

Chapter 1 Overview of vCloud Director Installation, Configuration, and Upgrade

vCloud Director Hardware and Software Requirements

Each server in a vCloud Director server group must meet certain hardware and software requirements. In addition, a supported database must be accessible to all members of the group. Each server group requires access to a vCenter server, a vShield Manager or NSX Manager, and one or more ESXi hosts.

Supported Platforms

Current information about the VMware platforms supported by this release of vCloud Director is available from the VMware Product Interoperability Matrixes located in VMware Partner Central. Log in to VMware

Partner Central using your VMware Partner account information.

vSphere Configuration Requirements

Servers and hosts intended for use with vCloud Director must meet specific configuration requirements.

n n n n vCenter networks intended for use as vCloud Director external networks or network pools must be available to all hosts in any cluster intended for vCloud Director to use. Making these networks available to all hosts in a datacenter simplifies the task of adding new vCenter servers to vCloud Director.

vSphere Distributed Switches must be used for cross-host fencing and network pool allocation.

vCenter clusters used with vCloud Director must configure storage DRS with an automation level of

Fully Automated. This configuration requires shared storage attached to all ESXi hosts in a DRS cluster.

vCloud Director can take full advantage of Storage DRS, including support for fast provisioning, with vCenter 5.1 or later.

vCenter servers must trust their hosts. All hosts in all clusters managed by vCloud Director must be configured to require verified host certificates. In particular, you must determine, compare, and select matching thumbprints for all hosts. See Configure SSL Settings in the vCenter Server and Host

Management documentation.

vSphere Licensing Requirements

vCloud Director requires the following vSphere licenses: n n

VMware DRS, licensed by vSphere Enterprise and Enterprise Plus.

VMware Distributed Switch and dvFilter, licensed by vSphere Enterprise Plus. This license enables creation and use of vCloud Director isolated networks.

VMware, Inc. 9

vCloud Director Installation and Upgrade Guide

Supported vCloud Director Server Operating Systems

Table 1

1. Supported vCloud Director Server Operating Systems

Operating System (64-bit only) Updates

CentOS 6

Red Hat Enterprise Linux 5

Red Hat Enterprise Linux 6

4

4-10

1-5

Disk Space

Requirements

Memory Requirements

Linux Software

Packages

Each vCloud Director server requires approximately 1350MB of free space for the installation and log files.

Each vCloud Director server must be provisioned with at least 4GB of memory.

Each vCloud Director server must include installations of several common

Linux software packages. These packages are typically installed by default with the operating system software. If any are missing, the installer fails with a diagnostic message.

Table 1

2. Required Software Packages

Package Name Package Name

alsa-lib bash chkconfig coreutils findutils glibc grep initscripts krb5-libs libgcc libICE libSM libstdc libX11 libXau libXdmcp libXext libXi libXt libXtst

Package Name

module-init-tools net-tools pciutils procps redhat-lsb sed tar which

N

OTE

Several procedures for configuring network connections and creating SSL certificates require the use of the Linux nslookup

command, which is available in the Linux bind-utils

package.

Supported vCloud Director Databases

vCloud Director supports Oracle and Microsoft SQL Server databases. The most current information about supported databases for this release of vCloud Director is available from the VMware Product Interoperability

Matrixes located in VMware Partner Central. Log in to VMware Partner Central using your VMware Partner account information.

For recommended database server configurations, see “Installing and Configuring a vCloud Director

Database,” on page 15.

10 VMware, Inc.

Chapter 1 Overview of vCloud Director Installation, Configuration, and Upgrade

Supported LDAP Servers

Table 1

3. Supported LDAP Servers

Platform LDAP Server

Windows Server 2003 Active Directory

Windows Server 2008 Active Directory

Windows 7 (2008 R2) Active Directory

Linux OpenLDAP

Authentication Methods

Simple, Simple SSL, Kerberos, Kerberos SSL

Simple

Simple, Simple SSL, Kerberos, Kerberos SSL

Simple, Simple SSL

Guest OS Support

See the vCloud Director User's Guide for a list of supported guest operating systems.

Supported Databases for Storing Historic Metric Data

You can configure your vCloud Director installation to store metrics that vCloud Director collects about virtual machine performance and resource consumption. Data for historic metrics is stored in a KairosDB

database backed by Cassandra. See Chapter 6, “Install and Configure Optional Database Software to Store and Retrieve Historic Virtual Machine Performance Metrics,” on page 67 for more information.

vCloud Director supports the following KairosDB and Cassandra versions.

n

KairosDB 0.9.1

n

Cassandra 1.2 and 2.0

Browsers That vCloud Director Supports

The vCloud Director Web Console is compatible with recent versions of Google Chrome, Mozilla Firefox, and Microsoft Internet Explorer.

N

OTE

The vCloud Director Web Console is compatible only with 32-bit browsers. When a browser is listed as supported on a 64-bit platform, use of a 32-bit browser on the 64-bit platform is implied.

Browser Support on Linux Platforms

On these Linux platforms, the vCloud Director Web Console is compatible with the most recent version of

Mozilla Firefox and Google Chrome, and with their immediate predecessor versions.

Table 1

4. Browser Support and Operating System Compatibility on Linux Platforms

Platform Google Chrome Mozilla Firefox

CentOS 6.x

Red Hat Enterprise Linux 6.x

Ubuntu 12.x

YES

YES

YES

YES

YES

YES

Browser Support on Windows Platforms

On Windows platforms, the vCloud Director Web Console is compatible with at least one version of

Microsoft Internet Explorer. Some Windows platforms are also compatible with the most recent version of

Mozilla Firefox and Google Chrome, and with their immediate predecessor versions.

VMware, Inc. 11

vCloud Director Installation and Upgrade Guide

Table 1

5. Browser Support and Operating System Compatibility on Microsoft Windows Platforms

Platform

Windows XP Pro

Windows Server 2003

Enterprise Edition

Windows Server 2008

Google

Chrome

YES

YES

YES

Windows Server 2008 R2 YES

Windows Vista YES

Windows 7 YES

Windows 8 YES

YES

YES

No

YES

YES

Mozilla

Firefox

YES

YES

Internet Explorer 8.x

YES

YES

YES

YES

YES

YES

No

YES

YES

YES

YES

No

Internet

Explorer 9.x

No

No

YES

YES

YES

YES

YES

Internet

Explorer

10.x

No

No

Browser Support on Macintosh Platforms

On Macintosh platforms, the vCloud Director Web Console is compatible with the most recent version of

Mozilla Firefox and Google Chrome, and with their immediate predecessor versions.

Supported Versions of Adobe Flash Player

The vCloud Director Web Console requires Adobe Flash Player 11.2 or later. Only the 32-bit version is supported.

Supported Versions of Java

vCloud Director clients must have JRE 1.6.0 update 10 or later installed and enabled. Only the 32-bit version is supported.

Supported TLS and SSL Protocol Versions and Cipher Suites

vCloud Director requires clients to use SSL. The following SSL server protocols are supported: n

TLS versions 1.0, 1.1, and 1.2

n

SSL version 3

Supported cipher suites include those with RSA, DSS, or Elliptic Curve signatures and DES3, AES-128, or

AES-256 ciphers.

12 VMware, Inc.

Chapter 1 Overview of vCloud Director Installation, Configuration, and Upgrade

Summary of Network Configuration Requirements for vCloud Director

Secure, reliable operation of vCloud Director depends on a secure, reliable network that supports forward and reverse lookup of hostnames, a network time service, and other services. Your network must meet these requirements before you begin installing vCloud Director.

The network that connects vCloud Director servers, the database server, vCenter servers, and the associated vCloud Networking and Security or NSX for vSphere components, must meet several requirements:

IP addresses

Console Proxy Address

Network Time Service

Server Time Zones

Hostname Resolution

Each vCloud Director server requires two IP addresses, so that it can support two different SSL connections. One connection is for the HTTP service. The other is for the console proxy service. You can use IP aliases or multiple network interfaces to create these addresses. You cannot use the Linux ip addr add

command to create the second address.

The IP address configured as the console proxy address must not be located behind an SSL-terminating load balancer or reverse proxy. All console proxy requests must be relayed directly to the console proxy IP address.

You must use a network time service such as NTP to synchronize the clocks of all vCloud Director servers, including the database server. The maximum allowable drift between the clocks of synchronized servers is 2 seconds.

All vCloud Director servers, including the database server, must be configured to be in the same time zone.

All host names that you specify during installation and configuration must be resolvable by DNS using forward and reverse lookup of the fully qualified domain name or the unqualified hostname. For example, for a host named vcloud.example.com

, both of the following commands must succeed on a vCloud Director host:

Transfer Server Storage

nslookup vcloud nslookup vcloud.example.com

In addition, if the host vcloud.example.com

has the IP address 192.168.1.1, the following command must return vcloud.example.com

: nslookup 192.168.1.1

To provide temporary storage for uploads, downloads, and catalog items that are published or subscribed externally, you must make an NFS or other shared storage volume accessible to all servers in a vCloud Director server group. This shared volume must have write permission for root. Each member of the server group must mount this volume at the same mountpoint, typically

/opt/vmware/vcloud-director/data/transfer

. Space on this volume is consumed in two ways: n n

Transfers (uploads and downloads) occupy this storage for as long as the transfer is in progress, and are removed when the transfer is complete. Transfers that make no progress for 60 minutes are marked as expired and cleaned up by the system. Because transferred images can be large, it is a good practice to allocate at least several hundred gigabytes for this use.

Catalog items in catalogs that are published externally and enable caching of published content occupy this storage for as long as they exist. (Items from catalogs that are published externally but do not enable caching do not occupy this storage.) If you enable organizations

VMware, Inc. 13

vCloud Director Installation and Upgrade Guide in your cloud to create catalogs that are published externally, it is safe to assume that hundreds or even thousands of catalog items will need space on this volume, and that each catalog item will be the size of a virtual machine in compressed OVF form.

N

OTE

If possible, the volume you use for transfer server storage should be one whose capacity can be easily expanded.

Network Security Recommendations

Secure operation of vCloud Director requires a secure network environment. Configure and test this network environment before you begin installing vCloud Director

Connect all vCloud Director servers to a network that is secured and monitored. vCloud Director network connections have several additional requirements: n

Do not connect vCloud Director directly to the public Internet. Always protect vCloud Director network connections with a firewall. Only port 443 (HTTPS) must be open to incoming connections.

Ports 22 (SSH) and 80 (HTTP) can also be opened for incoming connections if needed. All other incoming traffic from a public network must be rejected by the firewall.

Table 1

6. Ports That Must Allow Incoming Packets From vCloud Director Hosts

Port

111

920

61611

61616

Protocol

TCP, UDP

TCP, UDP

TCP

TCP

Comments

NFS portmapper used by transfer service

NFS rpc.statd used by transfer service

ActiveMQ

ActiveMQ n

Do not connect the ports used for outgoing connections to the public network.

Table 1

7. Ports That Must Allow Outgoing Packets From vCloud Director Hosts

Port Protocol Comments

514

902

903

920

1433

1521

5672

25

53

111

123

389

443

TCP, UDP

TCP, UDP

TCP, UDP

TCP, UDP

TCP, UDP

TCP

UDP

TCP

TCP

TCP, UDP

TCP

TCP

TCP, UDP

SMTP

DNS

NFS portmapper used by transfer service

NTP

LDAP vCenter, vShield Manager, NSX Manager, and ESX connections

Optional. Enables syslog use.

vCenter and ESX connections.

vCenter and ESX connections.

NFS rpc.statd used by transfer service.

Default Microsoft SQL Server database port.

Default Oracle database port.

Optional. AMQP messages for task extensions.

14 VMware, Inc.

Chapter 1 Overview of vCloud Director Installation, Configuration, and Upgrade

Table 1

7. Ports That Must Allow Outgoing Packets From vCloud Director Hosts (Continued)

Port

61611

61616

Protocol

TCP

TCP

Comments

ActiveMQ

ActiveMQ n n

Route traffic between vCloud Director servers and the vCloud Director database server over a dedicated private network if possible.

Virtual switches and distributed virtual switches that support provider networks must be isolated from each other. They cannot share the same level 2 physical network segment.

Installing and Configuring a vCloud Director Database

vCloud Director cells use a database to store shared information. This database must exist before you can complete installation and configuration of vCloud Director software.

N

OTE

Regardless of the database software you choose, you must create a separate, dedicated database schema for vCloud Director to use. vCloud Director cannot share a database schema with any other

VMware product.

Configure an Oracle Database

Oracle databases have specific configuration requirements when you use them with vCloud Director. Install and configure a database instance and create the vCloud Director database user account before you install vCloud Director.

Procedure

1 Configure the database server.

A database server configured with 16GB of memory, 100GB storage, and 4 CPUs should be adequate for most vCloud Director clusters.

2 Create the database instance.

Use a command of the following form to create a single CLOUD_DATA tablespace:

Create Tablespace CLOUD_DATA datafile '$ORACLE_HOME/oradata/cloud_data01.dbf' size 1500M autoextend on;

3 Create the vCloud Director database user account.

The following command creates database user name vcloud

with password vcloudpass

.

Create user $vcloud identified by $vcloudpass default tablespace CLOUD_DATA;

N

OTE

When you create the vCloud Director database user account, you must specify CLOUD_DATA as the default tablespace.

4 Configure database connection, process, and transaction parameters.

The database must be configured to allow at least 75 connections per vCloud Director cell plus about 50 for Oracle's own use. You can obtain values for other configuration parameters based on the number of connections, where C represents the number of cells in your vCloud Director cluster.

Oracle Configuration Parameter

CONNECTIONS

PROCESSES

SESSIONS

Value for C Cells

75*C+50

= CONNECTIONS

= PROCESSES*1.1+5

VMware, Inc. 15

vCloud Director Installation and Upgrade Guide

Oracle Configuration Parameter Value for C Cells

TRANSACTIONS

OPEN_CURSORS

= SESSIONS*1.1

= SESSIONS

5 Create the vCloud Director database user account.

Do not use the Oracle system account as the vCloud Director database user account. You must create a dedicated user account for this purpose. Grant the following system privileges to the account: n n n n

CONNECT

RESOURCE

CREATE TRIGGER

CREATE TYPE n n n n

CREATE VIEW

CREATE MATERIALIZED VIEW

CREATE PROCEDURE

CREATE SEQUENCE

6 Note the database service name so you can use it when you configure network and database connections.

To find the database service name, open the file

$ORACLE_HOME/network/admin/tnsnames.ora

on the database server and look for an entry of the following form:

(SERVICE_NAME = orcl.example.com)

Configure a Microsoft SQL Server Database

SQL Server databases have specific configuration requirements when you use them with vCloud Director.

Install and configure a database instance, and create the vCloud Director database user account before you install vCloud Director.

vCloud Director database performance is an important factor in overall vCloud Director performance and scalability. vCloud Director uses the SQL Server tmpdb

file when storing large result sets, sorting data, and managing data that is being concurrently read and modified. This file can grow significantly when vCloud Director is experiencing heavy concurrent load. It is a good practice to create the tmpdb

file on a dedicated volume that has fast read and write performance. For more information about the tmpdb

file and

SQL Server performance, see http://msdn.microsoft.com/en-us/library/ms175527.aspx

.

Prerequisites

n

You must be familiar with Microsoft SQL Server commands, scripting, and operation.

n

To configure Microsoft SQL Server, log on to the SQL Server host computer using administrator credentials. You can configure SQL server to run with the LOCAL_SYSTEM identity, or any identity with the privilege to run a Windows service.

Procedure

1 Configure the database server.

A database server configured with 16GB of memory, 100GB storage, and 4 CPUs should be adequate for most vCloud Director clusters.

2 Specify Mixed Mode authentication during SQL Server setup.

Windows Authentication is not supported when using SQL Server with vCloud Director.

16 VMware, Inc.

Chapter 1 Overview of vCloud Director Installation, Configuration, and Upgrade

3 Create the database instance.

The following script creates the database and log files, specifying the proper collation sequence.

USE [master]

GO

CREATE DATABASE [vcloud] ON PRIMARY

(NAME = N'vcloud', FILENAME = N'C:\vcloud.mdf', SIZE = 100MB, FILEGROWTH = 10% )

LOG ON

(NAME = N'vcdb_log', FILENAME = N'C:\vcloud.ldf', SIZE = 1MB, FILEGROWTH = 10%)

COLLATE Latin1_General_CS_AS

GO

The values shown for SIZE are suggestions. You might need to use larger values.

4 Set the transaction isolation level.

The following script sets the database isolation level to READ_COMMITTED_SNAPSHOT.

USE [vcloud]

GO

ALTER DATABASE [vcloud] SET SINGLE_USER WITH ROLLBACK IMMEDIATE;

ALTER DATABASE [vcloud] SET ALLOW_SNAPSHOT_ISOLATION ON;

ALTER DATABASE [vcloud] SET READ_COMMITTED_SNAPSHOT ON WITH NO_WAIT;

ALTER DATABASE [vcloud] SET MULTI_USER;

GO

For more about transaction isolation, see http://msdn.microsoft.com/en-us/library/ms173763.aspx

.

5 Create the vCloud Director database user account.

The following script creates database user name vcloud

with password vcloudpass

.

USE [vcloud]

GO

CREATE LOGIN [vcloud] WITH PASSWORD = 'vcloudpass', DEFAULT_DATABASE =[vcloud],

DEFAULT_LANGUAGE =[us_english], CHECK_POLICY=OFF

GO

CREATE USER [vcloud] for LOGIN [vcloud]

GO

6 Assign permissions to the vCloud Director database user account.

The following script assigns the db_owner

role to the database user created in

Step 5 .

USE [vcloud]

GO sp_addrolemember [db_owner], [vcloud]

GO

Create SSL Certificates

vCloud Director uses SSL to secure communications between clients and servers. Before you install and configure a vCloud Director server group, you must create two certificates for each member of the group and import the certificates into host keystores.

Each vCloud Director server requires two IP addresses, so that it can support two different SSL endpoints.

Each endpoint requires its own SSL certificate. Certificates for both endpoints must include both an X.500

distinguished name and X.509 Subject Alternative Name extension.

VMware, Inc. 17

vCloud Director Installation and Upgrade Guide

Procedure

1 List the IP addresses for this server.

Use a command like ifconfig

to discover this server's IP addresses.

2 For each IP address, run the following command to retrieve the fully qualified domain name to which the IP address is bound.

nslookup ip-address

3 Make a note of each IP address, the fully qualified domain name associated with it, and whether vCloud Director should use the address for the HTTP service or the console proxy service.

You need the fully qualified domain names when you create the certificates, and the IP addresses when you configure network and database connections. If the IP address can be reached by other DNS names, make a note of those too, since you will need to supply them when specifying a Subject Alternative

Name.

4 Create the certificates.

You can use certificates signed by a trusted certification authority, or self-signed certificates.

N

OTE

Signed certificates provide the highest level of trust.

Create and Import a Signed SSL Certificate

Signed certificates provide the highest level of trust for SSL communications.

Each vCloud Director server requires two SSL certificates, one for the HTTP service and one for the console proxy service, in a Java keystore file. You can use certificates signed by a trusted certification authority, or self-signed certificates. Signed certificates provide the highest level of trust.

I

MPORTANT

These examples specify a 2,048-bit key size, but you should evaluate your installation's security requirements before choosing an appropriate key size. Key sizes less than 1,024 bits are no longer supported per NIST Special Publication 800-131A.

To create and import self-signed certificates, see

“Create a Self-Signed SSL Certificate,” on page 21.

Prerequisites

n

Generate a list of fully-qualified domain names and their associated IP addresses on this server.

n n n

Choose an address to use for the HTTP service and an address to use for the console proxy service. See

“Create SSL Certificates,” on page 17.

Verify that you have access to a computer that has a Java version 7 runtime environment, so that you can use the keytool

command to create the certificate. The vCloud Director installer places a copy of keytool

in

/opt/vmware/vcloud-director/jre/bin/keytool

, but you can perform this procedure on any computer that has a Java version 7 runtime environment installed. Certificates created with a keytool from any other source are not supported for use with vCloud Director. Creating and importing the certificates before you install and configure vCloud Director software simplifies the installation and configuration process. These command-line examples assume that keytool

is in the user's path. The keystore password is represented in these examples as passwd.

Certificates for both endpoints must include both an X.500 distinguished name and X.509 Subject

Alternative Name extension. Familiarize yourself with the keytool

command, especially its

-dname

and

-ext

options.

18 VMware, Inc.

Chapter 1 Overview of vCloud Director Installation, Configuration, and Upgrade n

Gather the information required for the argument to the keytool

-dname

option.

Table 1

8. Information required by keytool

-dname

option

X.500 Distinguished

Name Subpart keytool keyword Description

commonName CN organizationalUnit organizationName localityName stateName country

OU

O

L

S

C

The fully qualified domain name associated with the IP address of this endpoint.

The name of an organizational unit, such as a department or division, within the organization with which this certificate is associated

The name of the organization with which this certificate is associated

The name of the city or town in which the organization is located.

The name of the state or province in which the organization is located.

The name of the country in which the organization is located.

Example

CN=vcd1.example.com

OU=Engineering

O=Example Corporation

L=Palo Alto

S=California

C=US

Procedure

1 Create an untrusted certificate for the HTTP service.

This example command creates an untrusted certificate in a keystore file named certificates.ks

. The keytool

options have been placed on separate lines for clarity. The X.500 distinguished name information supplied in the argument to the

-dname

option uses the values shown in the Prerequisites.

The DNS and IP values shown in the argument to the

-ext

option are typical. Be sure to include all the

DNS names at which this endpoint can be reached, including the one you specified for the commonName

(CN) value in the

-dname

option argument . You can also include IP addresses, as shown here.

keytool

-keystore certificates.ks

-alias http

-storepass passwd

-keypass passwd

-storetype JCEKS

-genkeypair

-keyalg RSA

-keysize 2048

-validity 365

-dname "CN=vcd1.example.com, OU=Engineering, O=Example Corp, L=Palo Alto S=California

C=US"

-ext "san=dns:vcd1.example.com,dns:vcd1,ip:10.100.101.9"

I

MPORTANT

The keystore file and the directory in which it is stored must be readable by the user vcloud.vcloud

. The vCloud Director installer creates this user and group.

VMware, Inc. 19

vCloud Director Installation and Upgrade Guide

2 Create an untrusted certificate for the console proxy service.

This command adds an untrusted certificate to the keystore file created in

Step 1

. The keytool

options have been placed on separate lines for clarity. The X.500 distinguished name information supplied in the argument to the

-dname

option uses the values shown in the Prerequisites. The DNS and IP values shown in the argument to the

-ext

option are typical. Be sure to include all the DNS names at which this endpoint can be reached, including the one you specified for the commonName

(CN) value in the

dname

option argument . You can also include IP addresses, as shown here.

keytool

-keystore certificates.ks

-alias consoleproxy

-storepass passwd

-keypass passwd

-storetype JCEKS

-genkeypair

-keyalg RSA

-keysize 2048

-validity 365

-dname "CN=vcd2.example.com, OU=Engineering, O=Example Corp, L=Palo Alto S=California

C=US"

-ext "san=dns:vcd2.example.com,dns:vcd2,ip:10.100.101.10"

3 Create a certificate signing request for the HTTP service.

This command creates a certificate signing request in the file http.csr

.

keytool -keystore certificates.ks -storetype JCEKS -storepass passwd -certreq -alias http file http.csr

4 Create a certificate signing request for the console proxy service.

This command creates a certificate signing request in the file consoleproxy.csr

.

keytool -keystore certificates.ks -storetype JCEKS -storepass passwd -certreq -alias consoleproxy -file consoleproxy.csr

5 Send the certificate signing requests to your Certification Authority.

If your certification authority requires you to specify a Web server type, use Jakarta Tomcat.

6 When you receive the signed certificates, import them into the keystore file.

a Import the Certification Authority's root certificate into the keystore file.

This command imports the root certificate from the root.cer

file to the certificates.ks

keystore file.

keytool -storetype JCEKS -storepass passwd -keystore certificates.ks -import -alias root

-file root.cer

b (Optional) If you received intermediate certificates, import them into the keystore file.

This command imports intermediate certificates from the intermediate.cer

file to the certificates.ks

keystore file.

keytool -storetype JCEKS -storepass passwd -keystore certificates.ks -import -alias intermediate -file intermediate.cer

20 VMware, Inc.

Chapter 1 Overview of vCloud Director Installation, Configuration, and Upgrade c Import the certificate for the HTTP service.

This command imports the certificate from the http.cer

file to the certificates.ks

keystore file.

keytool -storetype JCEKS -storepass passwd -keystore certificates.ks -import -alias http

-file http.cer

d Import the certificate for the console proxy service.

This command imports the certificate from the consoleproxy.cer

file to the certificates.ks

keystore file.

keytool -storetype JCEKS -storepass passwd -keystore certificates.ks -import -alias consoleproxy -file consoleproxy.cer

7 To verify that all the certificates are imported, list the contents of the keystore file.

keytool -storetype JCEKS -storepass passwd -keystore certificates.ks -list

8 Repeat this procedure on all vCloud Director servers in the server group.

What to do next

If you created the certificates.ks

keystore file on a computer other than the server on which you generated the list of fully qualified domain names and their associated IP addresses, copy the keystore file to that server now. You will need the keystore path name when you run the configuration script. See

“Configure Network and Database Connections,” on page 30.

Create a Self-Signed SSL Certificate

Self-signed certificates can provide a convenient way to configure SSL for vCloud Director in environments where trust concerns are minimal.

Each vCloud Director server requires two SSL certificates, one for the HTTP service and one for the console proxy service, in a Java keystore file. You can use certificates signed by a trusted certification authority, or self-signed certificates. Signed certificates provide the highest level of trust.

I

MPORTANT

These examples specify a 2,048-bit key size, but you should evaluate your installation's security requirements before choosing an appropriate key size. Key sizes less than 1,024 bits are no longer supported per NIST Special Publication 800-131A.

To create and import signed certificates, see

“Create and Import a Signed SSL Certificate,” on page 18.

Prerequisites

n

Generate a list of fully-qualified domain names and their associated IP addresses on this server.

n n n

Choose an address to use for the HTTP service and an address to use for the console proxy service. See

“Create SSL Certificates,” on page 17.

Verify that you have access to a computer that has a Java version 7 runtime environment, so that you can use the keytool

command to create the certificate. The vCloud Director installer places a copy of keytool

in

/opt/vmware/vcloud-director/jre/bin/keytool

, but you can perform this procedure on any computer that has a Java version 7 runtime environment installed. Certificates created with a keytool from any other source are not supported for use with vCloud Director. Creating and importing the certificates before you install and configure vCloud Director software simplifies the installation and configuration process. These command-line examples assume that keytool

is in the user's path. The keystore password is represented in these examples as passwd.

Certificates for both endpoints must include both an X.500 distinguished name and X.509 Subject

Alternative Name extension. Familiarize yourself with the keytool

command, especially its

-dname

and

-ext

options.

VMware, Inc. 21

vCloud Director Installation and Upgrade Guide n

Gather the information required for the argument to the keytool

-dname

option.

Table 1

9. Information required by keytool

-dname

option

X.500 Distinguished

Name Subpart keytool keyword Description

commonName CN organizationalUnit organizationName localityName stateName country

OU

O

L

S

C

The fully qualified domain name associated with the IP address of this endpoint.

The name of an organizational unit, such as a department or division, within the organization with which this certificate is associated

The name of the organization with which this certificate is associated

The name of the city or town in which the organization is located.

The name of the state or province in which the organization is located.

The name of the country in which the organization is located.

Example

CN=vcd1.example.com

OU=Engineering

O=Example Corporation

L=Palo Alto

S=California

C=US

Procedure

1 Create an untrusted certificate for the HTTP service.

This example command creates an untrusted certificate in a keystore file named certificates.ks

. The keytool

options have been placed on separate lines for clarity. The X.500 distinguished name information supplied in the argument to the

-dname

option uses the values shown in the Prerequisites.

The DNS and IP values shown in the argument to the

-ext

option are typical. Be sure to include all the

DNS names at which this endpoint can be reached, including the one you specified for the commonName

(CN) value in the

-dname

option argument . You can also include IP addresses, as shown here.

keytool

-keystore certificates.ks

-alias http

-storepass passwd

-keypass passwd

-storetype JCEKS

-genkeypair

-keyalg RSA

-keysize 2048

-validity 365

-dname "CN=vcd1.example.com, OU=Engineering, O=Example Corp, L=Palo Alto S=California

C=US"

-ext "san=dns:vcd1.example.com,dns:vcd1,ip:10.100.101.9"

I

MPORTANT

The keystore file and the directory in which it is stored must be readable by the user vcloud.vcloud

. The vCloud Director installer creates this user and group.

22 VMware, Inc.

Chapter 1 Overview of vCloud Director Installation, Configuration, and Upgrade

2 Create an untrusted certificate for the console proxy service.

This command adds an untrusted certificate to the keystore file created in

Step 1

. The keytool

options have been placed on separate lines for clarity. The X.500 distinguished name information supplied in the argument to the

-dname

option uses the values shown in the Prerequisites. The DNS and IP values shown in the argument to the

-ext

option are typical. Be sure to include all the DNS names at which this endpoint can be reached, including the one you specified for the commonName

(CN) value in the

dname

option argument . You can also include IP addresses, as shown here.

keytool

-keystore certificates.ks

-alias consoleproxy

-storepass passwd

-keypass passwd

-storetype JCEKS

-genkeypair

-keyalg RSA

-keysize 2048

-validity 365

-dname "CN=vcd2.example.com, OU=Engineering, O=Example Corp, L=Palo Alto S=California

C=US"

-ext "san=dns:vcd2.example.com,dns:vcd2,ip:10.100.101.10"

3 To verify that all the certificates are imported, list the contents of the keystore file.

keytool -storetype JCEKS -storepass passwd -keystore certificates.ks -list

4 Repeat this procedure on all vCloud Director servers in the server group.

What to do next

If you created the certificates.ks

keystore file on a computer other than the server on which you generated the list of fully qualified domain names and their associated IP addresses, copy the keystore file to that server now. You will need the keystore path name when you run the configuration script. See

“Configure Network and Database Connections,” on page 30.

Install and Configure vShield Manager for a New vCloud Director Installation

vCloud Director depends on having either vShield Manager or NSX Manager to provide network services to the cloud. Before you perform a new installation of vCloud Director, you must install and configure either vShield Manager or NSX Manager and associate a unique instance of vShield Manager or NSX Manager with each vCenter Server that you plan to include in your vCloud Director installation.

vShield Manager is included in the VMware vCloud Networking and Security download. Current information about supported versions of vShield Manager that are compatible with vCloud Director is available from the VMware Product Interoperability Matrixes located in VMware Partner Central. Log in to

VMware Partner Central using your VMware Partner account information. For information about the

network requirements, see “vCloud Director Hardware and Software Requirements,” on page 9.

I

MPORTANT

This procedure applies only when you are performing a new installation of vCloud Director. If

you are upgrading an existing installation of vCloud Director, see Chapter 3, “Upgrading vCloud Director,” on page 39.

Prerequisites

n

Verify that each of your vCenter Server systems meets the prerequisites for installing vShield Manager.

n

Perform the installation task for the vShield Manager virtual appliance described in the vShield

Installation and Upgrade Guide.

VMware, Inc. 23

vCloud Director Installation and Upgrade Guide

Procedure

1 Log in to the vShield Manager virtual appliance that you installed and confirm the settings that you specified during installation.

2 Associate the vShield Manager virtual appliance that you installed with the vCenter Server system that you plan to add to vCloud Director in your planned vCloud Director installation.

What to do next

Configure VXLAN support in the associated vShield Manager. vCloud Director creates VXLAN network pools to provide network resources to Provider VDCs. If VXLAN support is not configured in the associated vShield Manager, Provider VDCs show a network pool error, and you must create a different type of network pool and associate it with the Provider VDC. For details about how to configure VXLAN support, see the vShield Administration Guide.

Install and Configure NSX Manager for a New vCloud Director Installation

vCloud Director depends on having either vShield Manager or NSX Manager to provide network services to the cloud. Before you perform a new installation of vCloud Director, you must install and configure either vShield Manager or NSX Manager and associate a unique instance of vShield Manager or NSX Manager with each vCenter Server that you plan to include in your vCloud Director installation.

NSX is included in the VMware NSX for vSphere download. Current information about supported versions of NSX Manager that are compatible with vCloud Director is available from the VMware Product

Interoperability Matrixes located in VMware Partner Central. Log in to VMware Partner Central using your

VMware Partner account information. For information about the network requirements, see “vCloud

Director Hardware and Software Requirements,” on page 9.

I

MPORTANT

This procedure applies only when you are performing a new installation of vCloud Director. If

you are upgrading an existing installation of vCloud Director, see Chapter 3, “Upgrading vCloud Director,” on page 39.

Prerequisites

n

Verify that each of your vCenter Server systems meets the prerequisites for installing NSX Manager.

n

Perform the installation task for the NSX Manager virtual appliance described in the NSX Installation

and Upgrade Guide.

Procedure

1 Log in to the NSX Manager virtual appliance that you installed and confirm the settings that you specified during installation.

2 Associate the NSX Manager virtual appliance that you installed with the vCenter Server system that you plan to add to vCloud Director in your planned vCloud Director installation.

What to do next

Configure VXLAN support in the associated NSX Manager. vCloud Director creates VXLAN network pools to provide network resources to Provider VDCs. If VXLAN support is not configured in the associated NSX

Manager, Provider VDCs show a network pool error, and you must create a different type of network pool and associate it with the Provider VDC. For details about configuring VXLAN support, see the NSX

Administration Guide.

24 VMware, Inc.

Chapter 1 Overview of vCloud Director Installation, Configuration, and Upgrade

Installing and Configuring an AMQP Broker

AMQP, the Advanced Message Queuing Protocol, is an open standard for message queuing that supports flexible messaging for enterprise systems. vCloud Director includes an AMQP service that you can configure to work with an AMQP broker, such as RabbitMQ, to provide cloud operators with a stream of notifications about events in the cloud. If you want to use this service, you must install and configure an

AMQP broker.

While use of an AMQP broker with vCloud Director is optional, a number of integrations use AMQP to communicate with vCloud Director. Consult the installation and configuration documents for any integrations you plan to use.

Procedure

1 Download the RabbitMQ Server from http://info.vmware.com/content/12834_rabbitmq .

2 Follow the RabbitMQ installation instructions to install RabbitMQ on any convenient host.

The RabbitMQ server host must be reachable on the network by each vCloud Director cell.

3 During the RabbitMQ installation, make a note of the values that you will need to supply when configuring vCloud Director to work with this RabbitMQ installation.

n n n n

The fully-qualified domain name of the RabbitMQ server host, for example amqp.example.com

.

A username and password that are valid for authenticating with RabbitMQ.

The port at which the broker listens for messages. The default is

5672

.

The RabbitMQ virtual host. The default is "

/

".

What to do next

By default, the vCloud Director AMQP service sends unencrypted messages. If you configure it to encrypt these messages using SSL, it verifies the broker's certificate by using the default JCEKS trust store of the Java runtime environment on the vCloud Director server. The Java runtime environment is typically located in the

$JRE_HOME/lib/security/cacerts

directory.

To use SSL with the vCloud Director AMQP service, select Use SSL on the AMQP Broker Settings section of the Extensibility page of the vCloud Director Web console, and provide either of the following: n n an SSL certificate pathname a JCEKS trust store pathname and password

If you do not need to validate the AMQP broker's certificate, you can select Accept all certificates.

Download and Install the VMware Public Key

The installation file is digitally signed. To verify the signature, you must download and install the VMware public key.

You can use the Linux rpm

tool and the VMware public key to verify the digital signature of the vCloud Director installation file, or any other signed downloaded file from vmware.com

. If you install the public key on the computer where you plan to install vCloud Director, the verification happens as part of the installation or upgrade. You can also manually verify the signature before you begin the installation or upgrade procedure, then use the verified file for all installations or upgrades.

N

OTE

The download site also publishes a checksum value for the download. The checksum is published in two common forms. Verifying the checksum verifies that the file contents that you downloaded are the same as the contents that were posted. It does not verify the digital signature.

VMware, Inc. 25

vCloud Director Installation and Upgrade Guide

Procedure

1 Create a directory to store the VMware Packaging Public Keys.

2 Use a Web browser to download all of the VMware Public Packaging Public Keys from the http://packages.vmware.com/tools/keys directory.

3 Save the key files to the directory that you created.

4 For each key that you download, run the following command to import the key.

# rpm --import /key_path/key_name

key_path is the directory in which you saved the keys.

key_name is the filename of a key.

26 VMware, Inc.

Creating a vCloud Director Server

Group

2

A vCloud Director server group consists of one or more vCloud Director servers that share a common database and other configuration details. To create a server group, you install and configure vCloud Director software on the first member of the group. Installation and configuration of the first group member creates a response file that you use to configure additional members of the group.

Prerequisites for Creating a vCloud Director Server Group

I

MPORTANT

This procedure is for new installations only. If you are upgrading an existing vCloud Director

installation, see Chapter 3, “Upgrading vCloud Director,” on page 39

Before you begin installing and configuring vCloud Director, complete all of the following tasks.

1 Verify that a supported vCenter Server system is running and properly configured for use with vCloud Director. For supported versions and configuration requirements, see

“Supported Platforms,” on page 9.

2 Verify that a supported vShield Manager or NSX Manager is running, associated with the vCenter

Server system, and properly configured for use with vCloud Director. For supported versions, see

“Supported Platforms,” on page 9. For installation and configuration details, see

“Install and Configure vShield Manager for a New vCloud Director Installation,” on page 23 and

“Install and Configure NSX

Manager for a New vCloud Director Installation,” on page 24.

3 Verify that you have at least one server platform that is supported for running the vCloud Director software and that server platform is configured with an appropriate amount of memory and storage.

For supported platforms and configuration requirements, see

“Supported vCloud Director Server

Operating Systems,” on page 10.

n

Each member of a server group requires two IP addresses: one to support an SSL connection for the

HTTP service and another for the console proxy service.

n n n

Each server must have an SSL certificate for each IP address. All directories in the pathname to the

SSL certificates must be readable by any user. See

“Create SSL Certificates,” on page 17.

For the transfer service, each server must mount an NFS or other shared storage volume at

/opt/vmware/vcloud-director/data/transfer

. This volume must have write permission for root.

See

“Summary of Network Configuration Requirements for vCloud Director,” on page 13.

Each server should have access to a Microsoft Sysprep deployment package. See “Install Microsoft

Sysprep Files on the Servers,” on page 35.

VMware, Inc. 27

vCloud Director Installation and Upgrade Guide

4 Verify that you have created a vCloud Director database and that it is accessible to all servers in the group. For a list of supported database software, see

“Supported vCloud Director Databases,” on page 10.

n n

Verify that you have created a database account for the vCloud Director database user and that the

account has all required database privileges. See “Installing and Configuring a vCloud Director

Database,” on page 15.

Verify that the database service starts when the database server is rebooted.

5 Verify that all vCloud Director servers, the database server, all vCenter Server systems, and those vCenter Server systems' associated vShield Manager or NSX Manager components can resolve each

other's names as described in “Summary of Network Configuration Requirements for vCloud

Director,” on page 13.

6 Verify that all vCloud Director servers and the database server are synchronized to a network time

server with the tolerances noted in “Summary of Network Configuration Requirements for vCloud

Director,” on page 13.

7 If you plan to import users or groups from an LDAP service, verify that the service is accessible to each vCloud Director server.

8

Open firewall ports as shown in “Network Security Recommendations,” on page 14. Port 443 must be

open between vCloud Director and vCenter Server systems.

This chapter includes the following topics: n n n n n n

“Install and Configure vCloud Director Software on the First Member of a Server Group,” on page 28

“Configure Network and Database Connections,” on page 30

“Install vCloud Director Software on Additional Members of a Server Group,” on page 34

“Install Microsoft Sysprep Files on the Servers,” on page 35

“Start or Stop vCloud Director Services,” on page 36

“Uninstall vCloud Director Software,” on page 37

Install and Configure vCloud Director Software on the First Member of a Server Group

All members of a vCloud Director share database connection and other configuration details that you specify when installing and configuring the first member of the group. These details are captured in a response file that you must use when adding members to the group.

vCloud Director software is distributed as a digitally signed Linux executable file named vmware-vclouddirector-5.6.0-

nnnnnn

.bin

, where nnnnnn represents a build number.

The vCloud Director installer verifies that the target server meets all platform prerequisites and installs vCloud Director software on it. After the software is installed on the target server, you must run a script that configures the server's network and database connections. This script creates a response file that you must use when configuring addiitonal members of this server group.

Prerequisites

n n

Verify that the target server and the network it connects to meet the requirements specified in

“Summary of Network Configuration Requirements for vCloud Director,” on page 13.

Verify that you have superuser credentials for the target server.

n

Verify that the target server mounts the shared transfer service storage volume at

/opt/vmware/vclouddirector/data/transfer

.

28 VMware, Inc.

Chapter 2 Creating a vCloud Director Server Group n

To have the installer verify the digital signature of the installation file, download and install the

VMware public key on the target server. If you already verified the digital signature of the installation file, you do not need to verify it again during installation. See

“Download and Install the VMware

Public Key,” on page 25.

Procedure

1 Log in to the target server as root.

2 Download the installation file to the target server.

If you purchased the software on a CD or other media, copy the installation file to a location that is accessible to all target servers.

3 Verify that the checksum of the download matches the one posted on the download page.

Values for MD5 and SHA1 checksums are posted on the download page. Use the appropriate tool to verify that the checksum of the downloaded installation file matches the one shown on the download page. A Linux command of the following form displays the checksum for installation-file.

[root@cell1 /tmp]#

md5sum installation-file

checksum-value installation-file

Compare the checksum-value produced by this command with the MD5 checksum copied from the download page.

4 Ensure that the installation file is executable.

The installation file requires execute permission. To be sure that it has this permission, open a console, shell, or terminal window and run the following Linux command, where installation-file is the full pathname to the vCloud Director installation file.

[root@cell1 /tmp]#

chmod u+x installation-file

5 In a console, shell, or terminal window, run the installation file.

To run the installation file, type its full pathname, for example:

[root@cell1 /tmp]#

./installation-file

The file includes an installation script and an embedded RPM package.

N

OTE

You cannot run the installation file from a directory whose pathname includes any embedded space characters.

The installer prints a warning of the following form if you have not installed the VMware public key on the target server.

warning:installation-file.rpm: Header V3 RSA/SHA1 signature: NOKEY, key ID 66fd4949

When the installer runs, it takes these actions.

a Verifies that the host meets all requirements b Verifies the digital signature on the installation file c Creates the vcloud

user and group d Unpacks the vCloud Director RPM package e Installs the software

After the software is installed, the installer prompts you to run the configuration script, which configures the server's network and database connections.

VMware, Inc. 29

vCloud Director Installation and Upgrade Guide

What to do next

Decide whether to run the configuration script.

n n

If you have completed the prerequisites listed in

“Prerequisites for Creating a vCloud Director Server

Group,” on page 27, you can run the configuration script now. Type

y

and press Enter.

If you are not ready to run the configuration script now, type

n

and press Enter to exit to the shell.

For more information about running the configuration script, see “Configure Network and Database

Connections,” on page 30.

Configure Network and Database Connections

After vCloud Director software is installed on the server, the installer prompts you to run a script that configures the server's network and database connections.

You must install vCloud Director software on the server before you can run the configuration script. The installer prompts you to run the script after installation is complete, but you can choose to run it later.

To run the script after the vCloud Director software is installed, log in as root, open a console, shell, or terminal window, and type:

/opt/vmware/vcloud-director/bin/configure

The configuration script creates network and database connections for a single vCloud Director server. The script also creates a response file that preserves database connection information for use in subsequent server installations.

N

OTE

After you run the configuration script to configure the first member of the server group, you must use the -r option and specify the response file pathname when configuring additional members of the

group. See “Protecting and Reusing the Response File,” on page 33.

Prerequisites

n n

Verify that a database of a supported type is accessible from the vCloud Director server. See “Installing and Configuring a vCloud Director Database,” on page 15 and

“vCloud Director Hardware and

Software Requirements,” on page 9.

Have the following information available: n n n n n

Location and password of the keystore file that includes the SSL certificates for this server. See

“Create and Import a Signed SSL Certificate,” on page 18. The configuration script does not run

with a privileged identity, so the keystore file and the directory in which it is stored must be readable by any user.

Password for each SSL certificate.

Hostname or IP address of the database server.

Database name and connection port.

Database user credentials (user name and password). This user must have specific database privileges. See

“Installing and Configuring a vCloud Director Database,” on page 15.

30 VMware, Inc.

Chapter 2 Creating a vCloud Director Server Group

Procedure

1 Specify the IP addresses to use for the HTTP and console proxy services running on this host.

Each member of a server group requires two IP addresses, so that it can support two different SSL connections: one for the HTTP service and another for the console proxy service. To begin the configuration process, choose which of the IP addresses discovered by the script should be used for each service.

Please indicate which IP address available on this machine should be used for the HTTP service and which IP address should be used for the remote console proxy.

The HTTP service IP address is used for accessing the user interface and the REST API.

The remote console proxy IP address is used for all remote console (VMRC) connections and traffic.

Please enter your choice for the HTTP service IP address:

1: 10.17.118.158

2: 10.17.118.159

Choice [default=1]:

2

Please enter your choice for the remote console proxy IP address

1: 10.17.118.158

Choice [default=1]:

2 Specify the full path to the Java keystore file.

Please enter the path to the Java keystore containing your SSL certificates and private keys:

/opt/keystore/certificates.ks

3 Type the keystore and certificate passwords.

Please enter the password for the keystore:

Please enter the private key password for the 'http' SSL certificate:

Please enter the private key password for the 'consoleproxy' SSL certificate:

4 Configure audit message handling options.

Services in each vCloud Director cell log audit messages to the vCloud Director database, where they are preserved for 90 days. To preserve audit messages longer, you can configure vCloud Director services to send audit messages to the syslog

utility in addition to the vCloud Director database.

Option

To log audit messages to both syslog and the vCloud Director database.

To log audit messages only to the vCloud Director database

Action

Type the syslog hostname or IP address.

Press Enter.

If you would like to enable remote audit logging to a syslog host please enter the hostname or IP address of the syslog server. Audit logs are stored by vCloud Director for 90 days. Exporting logs via syslog will enable you to preserve them for as long as necessary.

Syslog host name or IP address [press Enter to skip]:

10.150.10.10

5 Specify the port on which the syslog

process monitors the specified server.

The default is port 514.

What UDP port is the remote syslog server listening on? The standard syslog port is 514. [default=514]:

Using default value "514" for syslog port.

VMware, Inc. 31

vCloud Director Installation and Upgrade Guide

6 Specify the database type, or press Enter to accept the default value.

The following database types are supported:

1. Oracle

2. Microsoft SQL Server

Enter the database type [default=1]:

Using default value "1" for database type.

7 Specify database connection information.

The information that the script requires depends on your choice of database type. This example shows the prompts that follow specification of an Oracle database. Prompts for other database types are similar.

a Type the hostname or IP address of the database server.

Enter the host (or IP address) for the database:

10.150.10.78

b Type the database port, or press Enter to accept the default value.

Enter the database port [default=1521]:

Using default value "1521" for port.

c Type the database service name.

Enter the database service name [default=oracle]:

orcl.example.com

If you press Enter, the configuration script uses a default value, which might not be correct for some installations. For information about how to find the database service name for an Oracle database, see

“Configure an Oracle Database,” on page 15.

d Type the database user name and password.

Enter the database username:

vcloud

Enter the database password:

The script validates the information you supplied, then continues with three more steps.

1 It initializes the database and connects this server to it.

2 It offers to start vCloud Director services on this host.

3 It displays a URL at which you can connect to the Setup wizard after vCloud Director service starts.

This fragment shows a typical completion of the script.

Connecting to the database: jdbc:oracle:thin:vcloud/[email protected]:1521/vcloud

...........

Database configuration complete.

Once the vCloud Director server has been started you will be able to access the first-time setup wizard at this URL:

http://vcloud.example.com

Would you like to start the vCloud Director service now? If you choose not to start it now, you can manually start it at any time using this command:

service vmware-vcd start

Start it now? [y/n]:

y

Starting the vCloud Director service (this may take a moment).

The service was started; it may be several minutes before it is ready for use.

Please check the logs for complete details.

vCloud Director configuration is now complete. Exiting...

32 VMware, Inc.

Chapter 2 Creating a vCloud Director Server Group

What to do next

N

OTE

Database connection information and other reusable responses you supplied during configuration are preserved in a file located at

/opt/vmware/vcloud-director/etc/responses.properties

on this server.

This file contains sensitive information that you must reuse when you add more servers to a server group.

Preserve the file in a secure location, and make it available only when needed.

To add more servers to this group, see “Install vCloud Director Software on Additional Members of a Server

Group,” on page 34.

After vCloud Director services are running on all servers, you can open the Setup wizard at the URL

displayed when the script completes. See Chapter 4, “vCloud Director Setup,” on page 51.

Protecting and Reusing the Response File

Network and database connection details that you supply when you configure the first vCloud Director server are saved in a response file. This file contains sensitive information that you must reuse when you add more servers to a server group. Preserve the file in a secure location, and make it available only when needed.

The response file is created at

/opt/vmware/vcloud-director/etc/responses.properties

on the first server for which you configure network and database connections. When you add more servers to the group, you must use a copy of the response file to supply configuration parameters that all servers share.

Procedure

1 Protect the response file.

Save a copy of the file in a secure location. Restrict access to it, and make sure it is backed up to a secure location. When you back up the file, avoid sending cleartext across a public network.

2 Reuse the response file.

a Copy the file to a location accessible to the server you are ready to configure.

N

OTE

You must install vCloud Director software on a server before you can reuse the response file to configure it. All directories in the pathname to the response file must be readable by the user vcloud.vcloud

, as shown in this example.

[root@cell1 /tmp]#

ls -l responses.properties

-rw------- 1 vcloud vcloud 418 Jun 8 13:42 responses.properties

The installer creates this user and group.

b Run the configuration script, using the -r option and specifying the response file pathname.

Log in as root, open a console, shell, or terminal window, and type:

[root@cell1 /tmp]#

/opt/vmware/vcloud-director/bin/configure -r /path-to-response-file

What to do next

After you configure the additional servers, delete the copy of the response file you used to configure them.

VMware, Inc. 33

vCloud Director Installation and Upgrade Guide

Install vCloud Director Software on Additional Members of a Server

Group

You can add servers to a vCloud Director server group at any time. Because all servers in a server group must be configured with the same database connection details, you must use the response file created when you configured the first member of the group to supply this information when you configure additional members.

Prerequisites

n n

Verify that you can access the response file that was created when you installed and configured the first member of this server group. See

“Protecting and Reusing the Response File,” on page 33.

Verify that the vCloud Director database is accessible from this server.

n n

Verify that the SSL certificates that you created for this server are installed in a location that the installer

can access. See “Create and Import a Signed SSL Certificate,” on page 18. The configuration script does

not run with a privileged identity, so the keystore file and the path in which it is stored must be readable by any user. Using the same keystore path (for example,

/tmp/certificates.ks

) on all members of a server group simplifies the installation process.

Have the following information available: n

The password of the keystore file that includes the SSL certificates for this server.

n

Password for each SSL certificate.

Procedure

1 Log in to the target server as root.

2 Download the installation file to the target server.

If you purchased the software on a CD or other media, copy the installation file to a location that is accessible to all target servers.

3 Ensure that the installation file is executable.

The installation file requires execute permission. To be sure that it has this permission, open a console, shell, or terminal window and run the following Linux command, where installation-file is the full pathname to the vCloud Director installation file.

[root@cell1 /tmp]#

chmod u+x installation-file

4 Copy the response file to a location accessible to this server.

All directories in the pathname to the response file must be readable by root.

5

In a console, shell, or terminal window, run the installation file using the -r option and specifying the response file pathname.

To run the installation file, type its full pathname, for example:

[root@cell1 /tmp]#

./installation-file -r /path-to-response-file

The file includes an installation script and an embedded RPM package.

N

OTE

You cannot run the installation file from a directory whose pathname includes any embedded space characters.

The installer prints a warning of the following form if you have not installed the VMware public key on the target server.

warning:installation-file.rpm: Header V3 RSA/SHA1 signature: NOKEY, key ID 66fd4949

34 VMware, Inc.

Chapter 2 Creating a vCloud Director Server Group

When the installer runs with the -r option, it takes these actions.

a Verifies that the host meets all requirements b Verifies the digital signature on the installation file c Creates the vcloud

user and group d Unpacks the vCloud Director RPM package e Installs the software f Copies the response file to a location readable by vcloud.vcloud

g Runs the configuration script using the response file as input

When the configuration script runs, it looks for the certificates in the path saved in the response file (for example,

/tmp/certificates.ks

) , then prompts you to supply the keystore and certificate passwords. If the configuration script does not find valid certificates in the pathname saved in the response file, it prompts you for a pathname to the certificates.

6 (Optional) Repeat this procedure to add more servers to this server group.

What to do next

If your cloud needs to support guest customization for certain older Microsoft operating systems, install

Sysprep files on all members of the server group. See

“Install Microsoft Sysprep Files on the Servers,” on page 35.

After the configuration script finishes and vCloud Director services are running on all servers, you can open

the Setup wizard at the URL that appears when the script completes. See Chapter 4, “vCloud Director

Setup,” on page 51.

Install Microsoft Sysprep Files on the Servers

Before vCloud Director can perform guest customization on virtual machines with certain older Windows guest operating systems, you must install the appropriate Microsoft Sysprep files on each member of the server group.

Sysprep files are required only for some older Microsoft operating systems. If your cloud does not need to support guest customization for those operating systems, you do not need to install Sysprep files.

To install the Sysprep binary files, you copy them to a specific location on the server. You must copy the files to each member of the server group.

Prerequisites

Verify that you have access to the 32- and 64-bit Sysprep binary files for Windows 2003 and Windows XP.

Procedure

1 Log in to the target server as root.

2 Change directory to

$VCLOUD_HOME/guestcustomization/default/windows

.

[root@cell1 /]#

cd /opt/vmware/vcloud-director/guestcustomization/default/windows

3 Create a directory named sysprep

.

[root@cell1 /opt/vmware/vcloud-director/guestcustomization/default/windows]#

mkdir sysprep

4 For each guest operating system that requires Sysprep binary files, create a subdirectory of

$VCLOUD_HOME/guestcustomization/default/windows/sysprep

.

Subdirectory names are specific to a guest operating system.

VMware, Inc. 35

vCloud Director Installation and Upgrade Guide

Table 2

1. Subdirectory Assignments for Sysprep Files

Guest OS

Subdirectory to Create Under

$VCLOUD_HOME/guestcustomization/default/windows/sysprep

Windows 2003 (32-bit)

Windows 2003 (64-bit)

Windows XP (32-bit)

Windows XP (64-bit) svr2003 svr2003-64 xp xp-64

For example, to create a subdirectory to hold Sysprep binary files for Windows XP, use the following

Linux command.

[root@cell1 /opt/vmware/vcloud-director/guestcustomization/default/windows]#

mkdir sysprep/xp

5 Copy the Sysprep binary files to the appropriate location on each vCloud Director server in the server group.

6 Ensure that the Sysprep files are readable by the user vcloud.vcloud

.

Use the Linux chown

command to do this.

[root@cell1 /]#

chown -R vcloud:vcloud $VCLOUD_HOME/guestcustomization

When the Sysprep files are copied to all members of the server group, you can perform guest customization on virtual machines in your cloud. You do not need to restart vCloud Director after the Sysprep files are copied.

Start or Stop vCloud Director Services

After you complete installation and database connection setup on a server, you can start vCloud Director services on it. You can also stop these services if they are running.

The configuration script prompts you to start vCloud Director services. You can let the script start these services for you, or you can start the services yourself later. These services must be running before you can complete and initialize the installation.

vCloud Director services start whenever you reboot a server.

I

MPORTANT

If you are stopping vCloud Director services as part of a vCloud Director software upgrade, you

must use the cell management tool, which allows you to quiesce the cell before stopping services. See “Use the Cell Management Tool to Quiesce and Shut Down a Server,” on page 41.

Procedure

1 Log in to the target server as root.

2 Start or stop services.

Option

Start services

Stop services when the cell is in use

Stop services when the cell is not in use

Action

Open a console, shell, or terminal window and run the following command.

service vmware-vcd start

Use the cell management tool.

Open a console, shell, or terminal window and run the following command.

service vmware-vcd stop

36 VMware, Inc.

Chapter 2 Creating a vCloud Director Server Group

Uninstall vCloud Director Software

Use the Linux rpm

command to uninstall vCloud Director software from an individual server.

Procedure

1 Log in to the target server as root.

2 Unmount the transfer service storage, typically mounted at

/opt/vmware/vclouddirector/data/transfer

.

3 Open a console, shell, or terminal window and run the rpm

command.

rpm -e vmware-vcloud-director

VMware, Inc. 37

vCloud Director Installation and Upgrade Guide

38 VMware, Inc.

Upgrading vCloud Director

3

To upgrade vCloud Director to a new version, install the new version on each server in the vCloud Director server group, upgrade the vCloud Director database, and restart vCloud Director services. You must also upgrade the vSphere components that support vCloud Director, including each vShield Manager or NSX

Manager that is associated with each vCenter Server system included in the vCloud Director server group.

After you upgrade a vCloud Director server, you must also upgrade its vCloud Director database. The database stores information about the runtime state of the server, including the state of all vCloud Director tasks it is running. To ensure that no invalid task information remains in the database after an upgrade, you must ensure that no tasks are active on the server before you begin the upgrade.

I

MPORTANT

The upgrade process requires you to upgrade vCloud Director, each associated vCenter Server system and its associated vShield Manager or NSX Manager, and all hosts. You must prevent users from accessing vCloud Director until the upgrade of the associated vShield Manager or NSX Manager is complete.

The upgrade preserves the following artifacts: n

Local and global properties files are copied to the new installation.

n

Microsoft sysprep files used for guest customization are copied to the new installation.

If you use a load balancer to distribute client requests across members of your vCloud Director server group, you can upgrade a subset of the server group while keeping existing services available on the others.

If you do not have a load balancer, the upgrade requires sufficient vCloud Director downtime to upgrade the database and at least one server. You might also have to upgrade registered vCenter Server systems if they are not running a compatible version of vCenter software. Upgrading vCenter Server systems and ESXi hosts can incur additional vCloud Director downtime, because virtual machines are inaccessible while their hosts or vCenter Server systems are being upgraded.

SSL Certificates Must Include an X.509 Subject Alternative Name

Extension

Beginning with this release, SSL certificates used by vCloud Director must include both an X.500

distinguished name and an X.509 Subject Alternative Name extension. Previous releases did not verify the

Subject Alternative Name during the SSL handshake. Unless your existing certificates include the X.509

Subject Alternative Name extension, the SSL handshake will fail in this release, and clients will not be able to connect with vCloud Director.

SSL certificates that include an X.509 Subject Alternative Name extension are compatible with all previous releases of vCloud Director. It is a good practice to create and install the new certificates on your existing vCloud Director release before proceeding with he upgrade. Doing so allows you verify that SSL connection can be completed using the new certificates before you begin the upgrade process.

VMware, Inc. 39

vCloud Director Installation and Upgrade Guide

“Create SSL Certificates,” on page 17 provides detailed information about creating and importing signed

and self-signed certificates.

“Generating Self-Signed SSL Certificates,” on page 61 and

“Replacing SSL

Certificates,” on page 60 explain how to use the

cell-management-tool

to create new certificates and replace existing ones.

Upgrading a vCloud Director Server Group

1 Disable user access to vCloud Director. You can also display a maintenance message while the upgrade

is underway. See “Displaying the Maintenance Message During an Upgrade,” on page 41.

2 Use the cell management tool to quiesce all cells in the server group and shut down vCloud Director

services on each server. See “Use the Cell Management Tool to Quiesce and Shut Down a Server,” on page 41.

3

Upgrade vCloud Director software on all members of the server group. See “Upgrade vCloud Director

Software on Any Member of a Server Group,” on page 43. You can upgrade the servers individually

or in parallel, but you must not restart vCloud Director services on any upgraded member of the group before you upgrade the vCloud Director database.

4 Upgrade the vCloud Director database. See

“Upgrade the vCloud Director Database,” on page 45.

5 Restart vCloud Director on the upgraded servers. See

“Start or Stop vCloud Director Services,” on page 36.

6 Upgrade each associated vShield Manager or NSX Manager. All vShield Manager or NSX Manager installations registered to this server group must be upgraded to a version of vShield Manager or NSX

Manager software that is compatible with the version of vCloud Director installed by the upgrade. If the upgrade program detects an incompatible version of vShield Manager or NSX Manager, upgrading is not allowed. You must upgrade to the latest version of vShield Manager or NSX Manager as described in

“Supported Platforms,” on page 9 to use networking features introduced in this release of

vCloud Director. See “Upgrade the Existing vShield Manager or NSX Manager That Is Associated with an Attached vCenter Server System,” on page 47.

7 Enable user access to vCloud Director.

8

Upgrade each associated vCenter Server system and hosts. See “Upgrade vCenter Server Systems,

Hosts, and vShield Edge Appliances,” on page 48. All vCenter Server systems registered to this server

group must be upgraded to a version of vCenter Server software that is compatible with the version of vCloud Director installed by the upgrade. Incompatible vCenter Server systems become inaccessible from vCloud Director after the upgrade is complete. See

“Supported Platforms,” on page 9.

Using a Load Balancer to Reduce Service Downtime

If you are using a load balancer or other tool that can force requests to go to specific servers, you can upgrade a subset of the server group while keeping existing services available on the remaining subset. This approach reduces vCloud Director service downtime to the length of time required to upgrade the vCloud Director database. Users might experience some degradation of performance during the upgrade, but in-progress tasks continue to run as long as any subset of the server group is operational. Console sessions might be interrupted, but you can restart them.

1 Use the load balancer to redirect vCloud Director requests to a subset of the servers in the group.

Follow the procedures recommended by your load balancer.

2 Use the cell management tool to quiesce the cells that are no longer handling requests and shut down vCloud Director services on those servers.

N

OTE

Console sessions routed through a server's console proxy are interrupted when the server shuts down. Clients can refresh the console window to recover.

See

“Use the Cell Management Tool to Quiesce and Shut Down a Server,” on page 41.

40 VMware, Inc.

Chapter 3 Upgrading vCloud Director

3 Upgrade vCloud Director software on the members of the server group on which you have stopped vCloud Director, but do not restart those services. See

“Upgrade vCloud Director Software on Any

Member of a Server Group,” on page 43.

4 Use the cell management tool to quiesce the cells that you have not yet upgraded and shut down vCloud Director services on those servers.

5 Upgrade the vCloud Director database. See

“Upgrade the vCloud Director Database,” on page 45.

6 Restart vCloud Director on the upgraded servers. See

“Start or Stop vCloud Director Services,” on page 36.

7 Upgrade each associated vShield Manager or NSX Manager. See

“Upgrade the Existing vShield

Manager or NSX Manager That Is Associated with an Attached vCenter Server System,” on page 47.

8

Upgrade each associated vCenter Server system and hosts. See “Upgrade vCenter Server Systems,

Hosts, and vShield Edge Appliances,” on page 48.

9 Use the load balancer to redirect vCloud Director requests to the upgraded servers.

10 Upgrade vCloud Director software on the remaining servers in the group, and restart vCloud Director on those servers as the upgrades complete. See

“Upgrade vCloud Director Software on Any Member of a Server Group,” on page 43.

Displaying the Maintenance Message During an Upgrade

If you anticipate a lengthy upgrade process and want to have the system display a maintenance message while the upgrade is underway, verify that at least one cell remains accessible while the others are being upgraded. Run the

/opt/vmware/vcloud-director/bin/vmware-vcd-cell

command on that cell to turn on the cell maintenance message.

[root@cell1 /opt/vmware/vcloud-director/bin]#

./vmware-vcd-cell maintenance

When you are ready to return an upgraded cell to service, run the following command on the cell to turn off the maintenance message.

[root@cell1 /opt/vmware/vcloud-director/bin]#

service vmware-vcd restart

This chapter includes the following topics: n n

“Use the Cell Management Tool to Quiesce and Shut Down a Server,” on page 41

“Upgrade vCloud Director Software on Any Member of a Server Group,” on page 43

n n n

“Upgrade the vCloud Director Database,” on page 45

“Upgrade the Existing vShield Manager or NSX Manager That Is Associated with an Attached vCenter

Server System,” on page 47

“Upgrade vCenter Server Systems, Hosts, and vShield Edge Appliances,” on page 48

Use the Cell Management Tool to Quiesce and Shut Down a Server

Before you upgrade a vCloud Director server, use the cell management tool to quiesce and shut down vCloud Director services on the server's cell.

vCloud Director creates a task object to track and manage each asynchronous operation that a user requests.

Information about all running and recently completed tasks is stored in the vCloud Director database.

Because a database upgrade invalidates this task information, you must be sure that no tasks are running when you begin the upgrade process.

VMware, Inc. 41

vCloud Director Installation and Upgrade Guide

With the cell management tool, you can suspend the task scheduler so that new tasks cannot be started, then check the status of all active tasks. You can wait for running tasks to finish or log in to vCloud Director as a

system administrator and cancel them. See Chapter 5, “Cell Management Tool Reference,” on page 55.

When no tasks are running, you can use the cell management tool to stop vCloud Director services.

Prerequisites

n

Verify that you have superuser credentials for the target server.

n n

Verify that you have vCloud Director system administrator credentials.

If this cell will be accessible to vCloud Director clients while it is being upgraded, use the

/opt/vmware/vcloud-director/bin/vmware-vcd-cell

command to turn on the cell maintenance message.

[root@cell1 /opt/vmware/vcloud-director/bin]#

./vmware-vcd-cell maintenance

This command causes the cell to respond to all requests with a maintenance message. If you use a load balancer or similar tool to make the cell inaccessible during the upgrade, you do not need to to turn on the cell maintenance message.

Procedure

1 Log in to the target server as root.

2 Use the cell management tool to gracefully shut down the cell.

a Retrieve the current job status.

The following cell-management-tool

command supplies system administrator credentials and returns the count of running jobs.

[root@cell1 /opt/vmware/vclouddirector/bin]#

./cell-management-tool -u administrator cell --status

Job count = 3

Is Active = true b Stop the task scheduler to quiesce the cell.

Use a cell-management-tool

command of the following form.

[root@cell1 /opt/vmware/vclouddirector/bin]#

./cell-management-tool -u administrator cell --quiesce true

This command prevents new jobs from being started. Existing jobs continue to run until they finish or are cancelled. To cancel a job, use the vCloud Director Web Console or the REST API.

c When the

Job count

value is

0

and the

Is Active

value is false

, it is safe to shut down the cell.

Use a cell-management-tool

command of the following form.

[root@cell1 /opt/vmware/vclouddirector/bin]#

./cell-management-tool -u administrator cell --shutdown

N

OTE

You can supply the vCloud Director system administrator password on the cellmanagement-tool

command line, but it is more secure to omit the password. This causes the cellmanagement-tool

to prompt for the password, which it does not display on the screen as you type.

Console sessions routed through a server's console proxy are interrupted when the server shuts down. If other members of the server group are still active, clients can refresh the console window to recover.

42 VMware, Inc.

Chapter 3 Upgrading vCloud Director

What to do next

After the cell management tool stops vCloud Director services on this server, you can upgrade the server's vCloud Director software or complete other maintenance that the server requires.

Upgrade vCloud Director Software on Any Member of a Server Group

The vCloud Director installer verifies that the target server meets all upgrade prerequisites and upgrades the vCloud Director software on the server.

vCloud Director software is distributed as a Linux executable file named vmware-vcloud-director-5.6.0-

nnnnnn

.bin

, where nnnnnn represents a build number. After the upgrade is installed on a member of a server group, you must run a tool that upgrades the vCloud Director database that the group uses before you can restart vCloud Director services on the upgraded server.

Prerequisites

n

Verify that you have superuser credentials for the target server.

n

To have the installer verify the digital signature of the installation file, download and install the

VMware public key on the target server. If you already verified the digital signature of the installation file, you do not need to verify it again during installation. See

“Download and Install the VMware

Public Key,” on page 25.

n n n

Create new SSL certificates for the target server. See

“SSL Certificates Must Include an X.509 Subject

Alternative Name Extension,” on page 39.

Use the cell management tool to quiesce and shut down vCloud Director services on the server's cell.

Verify that you have a valid license key to use the version of the vCloud Director software to which you are upgrading.

Procedure

1 Log in to the target server as root.

2 Download the installation file to the target server.

If you purchased the software on a CD or other media, copy the installation file to a location that is accessible to all target servers.

3 Verify that the checksum of the download matches the one posted on the download page.

Values for MD5 and SHA1 checksums are posted on the download page. Use the appropriate tool to verify that the checksum of the downloaded installation file matches the one shown on the download page. A Linux command of the following form displays the checksum for installation-file.

[root@cell1 /tmp]#

md5sum installation-file

checksum-value installation-file

Compare the checksum-value produced by this command with the MD5 checksum copied from the download page.

4 Ensure that the installation file is executable.

The installation file requires execute permission. To be sure that it has this permission, open a console, shell, or terminal window and run the following Linux command, where installation-file is the full pathname to the vCloud Director installation file.

[root@cell1 /tmp]#

chmod u+x installation-file

5 Use the cell management tool to quiesce the cell and shut down vCloud Director services on the server.

See

“Use the Cell Management Tool to Quiesce and Shut Down a Server,” on page 41.

VMware, Inc. 43

vCloud Director Installation and Upgrade Guide

6 In a console, shell, or terminal window, run the installation file.

To run the installation file, type its full pathname, for example

./installation-file

. The file includes an installation script and an embedded RPM package.

N

OTE

You cannot run the installation file from a directory whose pathname includes any embedded space characters.

If the installer detects a version of vCloud Director installed on this server that is equal to or later than the version in the installation file, it displays an error message and exits. Otherwise, it prompts you to confirm that you are ready to proceed to upgrade this server.

Checking architecture...done

Checking for a supported Linux distribution...done

Checking for necessary RPM prerequisites...done

Checking free disk space...done

An older version of VMware vCloud Director has been detected

7 Respond to the upgrade prompt.

Option Action

Continue the upgrade.

Type y.

Exit to the shell without making any changes in the current installation.

Type n.

After you confirm that you are ready to upgrade the server, the installer verifies that the host meets all requirements, unpacks the vCloud Director RPM package, stops vCloud Director services on the server, and upgrades the installed vCloud Director software.

Do you wish to proceed with the upgrade? (y/n)? y

Extracting vmware-vcloud-director ......done

Upgrading VMware vCloud Director...

Installing the VMware vCloud Director

Preparing... ################################################## vmware-vcloud-director ##################################################

Migrating settings and files from previous release...done

Migrating in-progress file transfers to /opt/vmware/vcloud-director/data/transfer...done

Uninstalling previous release...done

The installer displays a warning of the following form if you did not install the VMware public key on the target server.

warning:installation-file.rpm: Header V3 RSA/SHA1 signature: NOKEY, key ID 66fd4949

The installer displays a warning of the following form when it makes changes to the existing global.properties

file on the target server.

warning: /opt/vmware/vcloud-director/etc/global.properties created as /opt/vmware/vclouddirector/etc/global.properties.rpmnew

Most upgrades require this sort of change, and display this warning. If you have made any changes to the existing global.properties

file, you can retrieve them from global.properties.rpmnew

.

44 VMware, Inc.

Chapter 3 Upgrading vCloud Director

8 (Optional) Update logging properties.

After an upgrade, new logging properties are written to the file

/opt/vmware/vclouddirector/etc/log4j.properties.rpmnew

.

Option

If you did not change existing logging properties

If you changed logging properties

Action

Copy this file to /opt/vmware/vclouddirector/etc/log4j.properties

.

Merge /opt/vmware/vclouddirector/etc/log4j.properties.rpmnew

file with the existing /opt/vmware/vcloud-director/etc/log4j.properties.

Merging these files preserves your changes.

When the vCloud Director software upgrade is complete, the installer displays a message indicating where the old configuration files are stored, then reminds you to run the database upgrade tool.

What to do next

n

If you have not already done so, upgrade the vCloud Director database that this server uses.

n

If you already upgraded the vCloud Director database that this server group uses, you can restart the upgraded server. See

“Start or Stop vCloud Director Services,” on page 36.

Upgrade the vCloud Director Database

After you upgrade a server in your vCloud Director server group, you must upgrade the group's vCloud Director database before you restart vCloud Director services on the server.

All servers in a vCloud Director server group share the same database, so regardless of how many servers you are upgrading, you need to upgrade the database only once. After the database is upgraded, vCloud Director servers cannot connect to it until they, too, are upgraded.

Prerequisites

I

MPORTANT

Back up your existing database before you upgrade it. Use the procedures that your database software vendor recommends.

Verify that all vCloud Director cells are inactive. See “Use the Cell Management Tool to Quiesce and Shut

Down a Server,” on page 41

Procedure

1 Open a console, shell, or terminal window, and type the following command to run the database upgrade script.

/opt/vmware/vcloud-director/bin/upgrade

I

MPORTANT

If the database upgrade script detects that an incompatible version of vShield Manager or

NSX Manager is registered to this installation of vCloud Director, it displays a warning message and cancels the upgrade.

One or more vShield Manager servers registered to this vCloud

Director installation are not supported by the version of vCloud Director you are upgrading to. Upgrade canceled, please follow the procedures in the vShield Manager Upgrade Guide to upgrade those unsupported vShield

Manager servers.

VMware, Inc. 45

vCloud Director Installation and Upgrade Guide

2 Respond to the database upgrade prompts.

a Confirm that you want to continue with the database upgrade.

Welcome to the vCloud Director upgrade utility

This product is intended for use only by service providers under the terms and conditions of the VMware Service Provider Partner (VSPP)

Program. If you are a member of the VSPP Program, please locate your license key before proceeding. If you are not a member of this program, do not proceed with this upgrade. Upgrading without a proper key will invalidate your support contract.

This utility will apply several updates to the database. Please ensure you have created a backup of your database prior to continuing.

Do you wish to upgrade the product now? [Y/N]:

Take one of the following actions:

Option Action

Continue the upgrade.

Type y.

Exit to the shell without making any changes in the current vCloud Director database.

Type n.

b (Optional) Wait for cells to become inactive, if necessary.

If the database upgrade tool detects that any cells are still active, it prompts you to continue with the upgrade or exit.

Found active cell. Name: "cell-01", IP Address: 10.150.151.190, Identifier: a2eb...

Do you wish to upgrade the database while cells are still active? [Y/N]

If you see this prompt, type n

to exit to the shell, then wait five minutes and restart the database upgrade tool. If the database upgrade tool continues to warn you about cells that are still active, return to the procedure in

“Use the Cell Management Tool to Quiesce and Shut Down a Server,” on page 41 and ensure that all cells have become inactive.

After you have responded to all prompts, the database upgrade tool runs and displays progress messages.

Executing upgrade task: Start UpdateStatementManager

...[3]

Successfully ran upgrade task

Executing upgrade task: ...

.......... Successfully ran upgrade task

...

Executing upgrade task: Stop UpdateStatementManager

...[3]

...

Successfully ran upgrade task

46 VMware, Inc.

Chapter 3 Upgrading vCloud Director

3 (Optional) Rebuild the database indexes and update the database statistics.

These procedures can lead to better database performance after the upgrade.

Do you wish to rebuild the database indexes? This may take several minutes. [Y/N]

y

Rebuilding database indexes

...

Do you wish to update the database statistics? This may take several minutes. [Y/N]

y

Updating database statistics

...

After the database is upgraded, the upgrade script offers to start vCloud Director services on this host.

Would you like to start the vCloud Director service now? If you choose not to start it now, you can manually start it at any time using this command:

service vmware-vcd start

Start it now? [y/n]:

y

Starting the vCloud Director service (this may take a moment).

Upgrade the Existing vShield Manager or NSX Manager That Is

Associated with an Attached vCenter Server System

Before you upgrade a vCenter Server system and hosts attached to vCloud Director, you must upgrade the vShield Manager or NSX Manager that is associated with that vCenter Server system.

Upgrading vShield Manager or NSX Manager interrupts access to the administrative functions of vShield

Manager or NSX Manager, but does not interrupt network services.

Prerequisites

n n

Verify that at least one upgraded cell in your vCloud Director installation is running before you begin the upgrade. The cell writes data about the upgraded vShield Manager or NSX Manager to the vCloud Director database.

Verify that you have the items that are required for upgrading vShield Manager or NSX Manager, depending on which one you are upgrading.

vShield Manager

See the upgrade information available from the VMware vCloud Networking and Security Documentation Center at https://www.vmware.com/support/pubs/vshield_pubs.html.

NSX Manager

See the upgrade information available from the NSX for vSphere Documentation Center at https://www.vmware.com/support/pubs/nsx_pubs.html.

VMware, Inc. 47

vCloud Director Installation and Upgrade Guide

Procedure

1 Upgrade the associated vShield Manager or NSX Manager installation by following the upgrade procedure that is appropriate for the product and version to which you are upgrading.

C

AUTION

When you upgrade to a version of NSX Manager, do not upgrade the existing associated vShield Edge appliances to NSX Edge appliances. vCloud Director does not support NSX Edge appliances. When you use NSX Manager with vCloud Director, vCloud Director uses NSX Manager to create vShield Edge appliances.

Option Action

Upgrade an associated vShield

Manager to a later version of vShield Manager.

See the Upgrade vShield Manager information in the vShield Installation

and Upgrade Guide at https://www.vmware.com/support/pubs/vshield_pubs.html. Upgrade only vShield Manager, and no other vShield components. Do not upgrade the existing associated vShield Edge appliances.

Upgrade an associated vShield

Manager to NSX Manager, or upgrade an associated NSX

Manager to a later version of NSX

Manager.

See the Upgrade to NSX Manager information in the NSX Installation and

Upgrade Guide at https://www.vmware.com/support/pubs/nsx_pubs.html.

Upgrade only vShield Manager or NSX Manager, and no other vShield or

NSX for vSphere components. Do not upgrade the existing associated vShield Edge appliances.

2

Repeat Step 1

for each vShield Manager or NSX Manager associated with the other vCenter Server systems registered to your cloud.

After the upgrade finishes, the now upgraded vShield Manager or NSX Manager notifies vCloud Director that the software is at a new version. It can take several minutes before the notification is sent and vCloud Director processes it.

What to do next

After you upgrade each associated vShield Manager or NSX Manager, you must upgrade all of the registered vCenter Server systems and hosts before you use vCloud Director to upgrade the associated vShield Edge appliances. See

“Upgrade vCenter Server Systems, Hosts, and vShield Edge Appliances,” on page 48.

Upgrade vCenter Server Systems, Hosts, and vShield Edge

Appliances

After you have upgraded vCloud Director and vShield Manager or NSX Manager, you must upgrade the vCenter Server systems and hosts attached to your cloud. After all of the attached vCenter Server systems and hosts are upgraded, then you must use vCloud Director to upgrade the associated vShield Edge appliances by redeploying edge gateways or resetting the vApp networks.

Prerequisites

Verify that you have already upgraded each vShield Manager or NSX Manager that is associated with the vCenter Server systems that are attached to your cloud. See

“Upgrade the Existing vShield Manager or NSX

Manager That Is Associated with an Attached vCenter Server System,” on page 47.

Procedure

1 Upgrade the attached vCenter Server system.

See the vSphere Installation and Setup Guide.

2 Verify all vCloud Director public URLs and certificate chains.

On the Administration tab of the vCloud Director Web console, click Public Addresses in the left pane.

Enter values for all fields

48 VMware, Inc.

Chapter 3 Upgrading vCloud Director

3 (Optional) If you have configured vCloud Director to use vCenter Single Sign On, you must unregister and re-register vCloud Director with the vCenter Lookup Service.

a Log in to vCloud Director as a system administrator using a local or LDAP account. Do not use vCenter Single Sign On for this log in.

b Unregister vCloud Director with the vCenter Lookup Service.

On the Administration tab of the vCloud Director Web console, click Federation in the left pane, and click Unregister. You must provide the appropriate vCenter administrator credentials to complete this action.

c Register vCloud Director with the vCenter Lookup Service.

See "Configure vCloud Director to use vCenter Single Sign On" in thevCloud Director

Administrator's Guide

4 Refresh the vCenter Server system's registration with vCloud Director.

a In the vCloud Director Web console, click the Manage & Monitor tab and click vCenters in the left pane.

b Right-click the vCenter Server name and select Refresh.

c Click Yes.

5 Upgrade each host that the upgraded vCenter Server system supports.

See the vSphere Installation and Setup Guide. For each host, the upgrade requires the following steps: a In the vCloud Director Web console, disable the host.

On the Manage and Monitor page, click Hosts, then right-click the host and select Disable Host.

b Use the vCenter Server system to put the host into maintenance mode and allow all the virtual machines on that host to migrate to another host.

c Upgrade the host.

To ensure that you have enough upgraded host capacity to support the virtual machines in your cloud, upgrade hosts in small batches. When you do this, host agent upgrades can complete in time to allow virtual machines to migrate back to the upgraded host.

d Use the vCenter Server system to reconnect the host.

e Upgrade the vCloud Director host agent on the host.

See "Upgrade an ESX/ESXi Host Agent" in the vCloud Director Administrator's Guide.

f In the vCloud Director Web console, enable the host.

On the Manage and Monitor page, click Hosts, then right-click the host and select Enable Host.

g Use the vCenter Server system to take the host out of maintenance mode.

6 Use your upgraded vCloud Director to upgrade all vShield Edge appliances managed by the upgraded vShield Manager or NSX Manager associated with the upgraded vCenter Server system.

C

AUTION

If the upgraded vCenter Server system is associated with NSX Manager instead of vShield

Manager, only use the methods described in this step to automatically upgrade the vShield Edge appliances using vCloud Director. Do not use any other methods to upgrade the associated vShield

Edge appliances to NSX Edge appliances. vCloud Director does not support NSX Edge appliances.

When you use NSX Manager with vCloud Director, vCloud Director uses NSX Manager to create vShield Edge appliances.

VMware, Inc. 49

vCloud Director Installation and Upgrade Guide

An appropriate upgrade of a vShield Edge appliance occurs automatically when you use either the vCloud Director Web console or REST API to reset a network that vShield Edge protects.

n

For an edge gateway, redeploying the edge gateway upgrades the vShield Edge appliance associated with that edge gateway.

n

For vApp networks that the virtual machines connect to, such as routed vApp networks, isolated vApp networks, or fenced organization virtual datacenter networks, resetting the vApp network from within the context of the vApp upgrades the vShield Edge appliance associated with that network. To use vCloud Director Web console to reset a vApp network from within the context of a vApp, navigate to the Networking tab for the vApp, display its networking details, right-click the vApp network, and select Reset Network.

For more information on how to redeploy edge gateways and reset vApp networks, see the vCloud Director Web console online help or the vCloud API Programming Guide, depending on which method you want to use.

What to do next

Repeat this procedure for the other vCenter Server systems registered to your cloud.

50 VMware, Inc.

vCloud Director Setup

4

After you configure all servers in the vCloud Director server group and connect them to the database, you can initialize the server group's database with a license key, system administrator account, and related information. When this process is complete, you can use the vCloud Director Web Console to complete the initial provisioning of your cloud.

Before you can run the vCloud Director Web Console, you must run the Setup wizard, which gathers the information that the Web Console requires before it can start. After the wizard is finished, the Web Console starts and displays the login screen. The vCloud Director Web Console provides a set of tools for provisioning and managing a cloud. It includes a Quickstart feature that guides you through steps like attaching vCloud Director to vCenter and creating an organization.

Prerequisites

n n

Complete the installation of all vCloud Director servers, and verify that vCloud Director services have started on all servers.

Verify that you have the URL that the configuration script displays when it completes.

N

OTE

To discover the URL of the Setup wizard after the script exits, look up the fully qualified domain name associated with the IP address you specified for the HTTP service during installation of the first server and use it to construct a URL of the form https://fully-qualified-domain-name, for example, https://mycloud.example.com. You can connect to the wizard at that URL.

Complete the installation of all vCloud Director servers, and verify that vCloud Director services have started on all servers.

Procedure

1 Open a Web browser and connect to the URL that the configuration script displays when it completes.

2 Follow the prompts to complete the setup.

This chapter includes the following topics: n n n n n

“Review the License Agreement,” on page 52

“Enter the License Key,” on page 52

“Create the System Administrator Account,” on page 52

“Specify System Settings,” on page 52

“Ready to Log In to vCloud Director,” on page 53

VMware, Inc. 51

vCloud Director Installation and Upgrade Guide

Review the License Agreement

Before you can configure a vCloud Director server group, you must review and accept the end user license agreement.

Procedure

1 Review the license agreement.

2 Accept or reject the agreement.

Option

To accept the license agreement.

Action

Click Yes, I accept the terms in the license agreement.

To reject the license agreement

No, I do not accept the terms in the license agreement.

If you reject the license agreement, you cannot proceed with vCloud Director configuration.

Enter the License Key

Each vCloud Director cluster requires a license to run. The license is specified as a product serial number.

The product serial number is stored in the vCloud Director database.

The vCloud Director product serial number is not the same as the vCenter server license key. To operate a vCloud, you must have a vCloud Director product serial number and a vCenter server license key. You can obtain both types of license keys from the VMware License Portal.

Procedure

1 Obtain a vCloud Director product serial number from the VMware License Portal.

2 Type the product serial number in the Product serial number text box.

Create the System Administrator Account

Specify the user name, password, and contact information for the vCloud Director system administrator.

The vCloud Director system administrator has superuser privileges throughout the cloud. You create the initial system administrator account during vCloud Director setup. After installation and configuration is complete, this system administrator can create additional system administrator accounts as needed.

Procedure

1 Type the system administrator's user name.

2 Type the system administrator's password and confirm it.

3 Type the system administrator's full name.

4 Type the system administrator's email address.

Specify System Settings

You can specify the system settings that control how vCloud Director interacts with vSphere and vShield

Manager or NSX Manager.

The configuration process creates a folder in the attached vCenter Server system for vCloud Director to use and specifies an installation ID to use when you create MAC addresses for virtual NICs.

Procedure

1 Type a name for the vCloud Director vCenter Server folder in the System name field.

52 VMware, Inc.

Chapter 4 vCloud Director Setup

2 Use the Installation ID field to specify the installation ID for this installation of vCloud Director.

If a datacenter includes multiple installations of vCloud Director, each installation must specify a unique installation ID.

Ready to Log In to vCloud Director

After you provide all of the information that the Setup Wizard requires, you can confirm your settings and complete the wizard. After the wizard finishes, the login screen of the vCloud Director Web Console appears.

The Ready to Log In page lists all the settings you have provided to the wizard. Review the settings carefully.

Prerequisites

Verify that you have access to the vCenter Server system that you want to use with your cloud, and to that vCenter Server system's associated vShield Manager or NSX Manager. The vCloud Director Web Console requires access to the installations of vCenter Server and vShield Manager or NSX Manager that you want to configure as part of this vCloud Director installation. These installations must be running and configured to work with each other before you finish this task. For more information about the configuration requirements, see

“vCloud Director Hardware and Software Requirements,” on page 9.

Procedure

n

To change a setting, click Back until you get to the page where the setting originated.

n

To confirm all settings and complete the configuration process, click Finish.

When you click Finish, the wizard applies the settings you specified, then starts the vCloud Director Web

Console and displays its login screen.

What to do next

Use the displayed login screen to log in to the vCloud Director Web Console using the user name and password you provided for the system administrator account. After you have logged in, the console displays a set of Quickstart steps that you must complete before you can use this cloud. When the steps are complete, the Guided Tasks are enabled, and your cloud is ready for use.

VMware, Inc. 53

vCloud Director Installation and Upgrade Guide

54 VMware, Inc.

Cell Management Tool Reference

5

The cell management tool is a command-line utility that you can use to manage a cell and its SSL certificates, and to export tables from the vCloud Director database. Superuser or system administrator credentials are required for some operations.

The cell management tool is installed in

/opt/vmware/vcloud-director/bin/cell-management-tool

.

Listing Available Commands

To list the available cell management tool commands, use the following command line.

cell-management-tool -h

Example: Cell Management Tool Usage Help

[root@cell1 /opt/vmware/vcloud-director/bin]#

./cell-management-tool -h

usage: cell-management-tool

-h,--help print this message

Available commands: cell - Manipulates the Cell and core components certificates - Reconfigures the SSL certificates for the cell ciphers - Reconfigure the list of disallowed SSL ciphers for the cell configure-metrics - Collects and stores properties necessary for collecting and querying metrics data dbextract - Exports the data from the given set of tables fix-scheduler-data - Scan database for corrupt scheduler data. Fix scheduler job data if corrupt.

generate-certs - Generates self-signed SSL certificates for use with vCD cell.

recover-password - Change a forgotten System Administrator password. Database credentials are required.

fail-tasks - Fail all tasks running on this cell and set a custom failure message.

For command specific help:

cell-management-tool <commandName> -h n

Managing a Cell on page 56

Use the cell command of the cell management tool to suspend the task scheduler so that new tasks cannot be started, to check the status of active tasks, to control cell maintenance mode, and to shut down the cell gracefully.

VMware, Inc. 55

vCloud Director Installation and Upgrade Guide n n n n n n n n

Exporting Database Tables on page 57

Use the dbextract command of the cell management tool to export data from the vCloud Director database.

Detecting and Repairing Corrupted Scheduler Data on page 60

If you know the vCloud Director database username and password, you can use the fix-scheduler-data

command of the cell management tool to scan the database for corrupt scheduler data and repair that data as needed.

Replacing SSL Certificates on page 60

Use the certificates command of the cell management tool to replace the cell's SSL certificates.

Generating Self-Signed SSL Certificates on page 61

Use the generate-certs command of the cell management tool to generate new self-signed SSL certificates for the cell.

Managing the List of Allowed SSL Ciphers on page 62

Use the ciphers command of the cell management tool to configure the set of cipher suites that the cell offers to use during the SSL handshake process.

Configuring the Metrics Database Connection on page 64

Use the configure-metrics command of the cell management tool to connect the cell to the optional metrics database.

Recovering the System Administrator Password on page 65

If you know the vCloud Director database username and password, you can use the recover-password

command of the cell management tool to recover the vCloud Director system administrator password.

Force Running Tasks to Complete on page 65

Use the fail-tasks command of the cell management tool to generate a list of tasks running on a quiesced cell that you can force to complete immediately with a status of failure.

Managing a Cell

Use the cell command of the cell management tool to suspend the task scheduler so that new tasks cannot be started, to check the status of active tasks, to control cell maintenance mode, and to shut down the cell gracefully.

To manage a cell, use a command line with the following form: cell-management-tool -u sysadmin-username -p sysadmin-password cell command

sysadmin-username sysadmin-password

Username of a vCloud Director system administrator.

Password of the vCloud Director system administrator.

N

OTE

You can supply the vCloud Director system administrator password on the cell-management-tool

command line, but it is more secure to omit the password. This causes the cell-management-tool

to prompt for the password, which it does not display on the screen as you type.

command

cell

subcommand.

56 VMware, Inc.

Chapter 5 Cell Management Tool Reference

Table 5

1. Cell Management Tool Options and Arguments, cell Subcommand

Command Argument Description

--help

(-h) None

--maintenance

(-m)

--quiesce

(-q)

--shutdown

(-s)

--status

(-t)

--status-verbose

(-tt) true

or false true

or false

None

None

None

Provides a summary of available commands in this category.

Controls cell maintenance mode.

The argument true puts the cell into maintenance mode. (You must quiesce the cell first.) The argument false releases the cell from maintenance mode.

Quiesces activity on the cell. The argument true suspends the scheduler. The argument false restarts the scheduler.

Shuts down vCloud Director services on the server.

Displays information about the number of tasks running on the cell and the status of the cell.

Displays verbose information about the tasks running on the cell and the status of the cell.

Example: Getting Task Status

The following cell-management-tool

command line supplies system administrator credentials and returns the count of running tasks. When the

Job count

value is

0

and the

Is Active

value is false

, you can safely shut down the cell.

[root@cell1 /opt/vmware/vclouddirector/bin]#

./cell-management-tool -u administrator cell --status

Job count = 3

Is Active = true

Exporting Database Tables

Use the dbextract command of the cell management tool to export data from the vCloud Director database.

To export database tables, use a command line with the following form: cell-management-tool dbextract options

Table 5

2. Cell Management Tool Options and Arguments, dbextract Subcommand

Option Argument Description

--help

(-h)

None

-categories

-dataFile

A comma-separated list of table categories to export.

An absolute path to a file describing the data to export.

Provides a summary of available commands in this category.

Optional. NETWORKING is the only supported category

Optional. If not supplied, the command uses

$VCLOUD_HOME/etc/data_to_exp ort.properties

. See “Specifying

Tables and Columns to Export,” on page 58.

VMware, Inc. 57

vCloud Director Installation and Upgrade Guide

Table 5

2. Cell Management Tool Options and Arguments, dbextract Subcommand (Continued)

Option

-dumpFolder

-exportSettingsFile

Argument

An absolute path to the folder in which to create the dump. The folder must exist and be writable by vcloud.vcloud.

An absolute path to a data export settings properties file.

Description

All data will be exported to a file in this folder.

-properties

-tables

An absolute path to a database connection properties file.

A comma-separated list of tables.

Optional. If not supplied, the command uses

$VCLOUD_HOME/etc/data_export

_settings.ini

. See

“Limiting and Ordering Exported Rows,” on page 59.

Optional. If not supplied, the command uses the database connection properties in

$VCLOUD_HOME/etc/global.prop

erties

. See

“Specifying a

Properties File,” on page 58.

Optional. Export all tables to see individual table names.

Specifying a Properties File

By default, the dbextract

command extracts data from the vCloud Director database using the database connection information in the current cell's

$VCLOUD_HOME/etc/global.properties

file. To extract data from a different vCloud Director database, specify the database connection properties in a file and use the

-properties

option to provide the pathname to that file on the command line. The properties file is a

UTF-8 file that has the following format.

username=username password=password servicename=db_service_name port=db_connection_port database-ip=db_server_ip_address db-type=db_type

username password db_service_name db_connection_port db_server_ip_address db_type

The vCloud Director database user name.

The vCloud Director database password.

The database service name. For example, orcl.example.com

.

The database port.

The IP address of the database server.

The database type. Must be

Oracle

or

MS_SQL

.

Specifying Tables and Columns to Export

To restrict the set of data exported, use the

-exportSettingsFile

option and create a data_to_export.properties

file that specifies individual tables and, optionally, columns to export. This file is a UTF-8 file that contains zero or more lines of the form TABLE_NAME:COLUMN_NAME.

TABLE_NAME

COLUMN_NAME

The name of a table in the database. To see a list of table names, export all tables.

The name of a column in the specified TABLE_NAME.

58 VMware, Inc.

Chapter 5 Cell Management Tool Reference

This example data_to_export.properties

file exports columns from the

ACL

and

ADDRESS_TRANSLATION tables.

ACL:ORG_MEMBER_ID

ACL:SHARABLE_ID

ACL:SHARABLE_TYPE

ACL:SHARING_ROLE_ID

ADDRESS_TRANSLATION:EXTERNAL_ADDRESS

ADDRESS_TRANSLATION:EXTERNAL_PORTS

ADDRESS_TRANSLATION:ID

ADDRESS_TRANSLATION:INTERNAL_PORTS

ADDRESS_TRANSLATION:NIC_ID

The command expects to find this file in

$VCLOUD_HOME/etc/data_to_export.properties

, but you can specify another path.

Limiting and Ordering Exported Rows

For any table, you can specify how many rows to export and how to order the exported rows. Use the

exportSettingsFile

option and create a data_export_settings.ini

file that specifies individual tables. This file is a UTF-8 file that contains zero or more entries of the following form:

[TABLE_NAME] rowlimit=int orderby=COLUMN_NAME

TABLE_NAME

COLUMN_NAME

The name of a table in the database. To see a list of table names, export all tables.

The name of a column in the specified TABLE_NAME.

This example data_export_settings.ini

restricts data exported from the

AUDIT_EVENT

table to the first 10000 rows and orders the rows by the value in the event_time

column

[AUDIT_EVENT] rowlimit=100000 orderby=event_time

The command expects to find this file in

$VCLOUD_HOME/etc/data_export_settings.ini

, but you can specify another path.

Example: Exporting All Tables From the Current vCloud Director Database.

This example exports all tables of the current vCloud Director database to the file

/tmp/dbdump

.

[root@cell1 /opt/vmware/vclouddirector/bin]#

./cell-management-tool dbextract -dumpFolder /tmp/dbdump

This utility outputs data from your vCloud Director system that may contain sensitive data.

Do you want to continue and output the data (y/n)?

y

Exporting data now. Please wait for the process to finish

Exported 144 of 145 tables.

VMware, Inc. 59

vCloud Director Installation and Upgrade Guide

Detecting and Repairing Corrupted Scheduler Data

If you know the vCloud Director database username and password, you can use the fix-scheduler-data command of the cell management tool to scan the database for corrupt scheduler data and repair that data as needed.

To scan database for corrupt scheduler data, use a command line with the following form: cell-management-tool fix-scheduler-data options

Table 5

3. Cell Management Tool Options and Arguments, fix-scheduler-data Subcommand

Option Argument Description

--help

(-h)

--dbuser

--dbpassword

None

The user name of the vCloud Director database user.

The password of the vCloud Director database user.

Provides a summary of available commands in this category.

Must be supplied on the command line.

Prompted for if not supplied.

Replacing SSL Certificates

Use the certificates command of the cell management tool to replace the cell's SSL certificates.

The certificates command of the cell management tool automates the process of replacing a cell's existing certificates with new ones stored in a JCEKS keystore. The certificates command helps you replace self-signed certificates with signed ones. To create a JCEKS keystore containing signed certificates, see

“Create and Import a Signed SSL Certificate,” on page 18 .

To replace the cell's SSL certificates, use a command with the following form: cell-management-tool certificates options

Table 5

4. Cell Management Tool Options and Arguments, certificates Subcommand

Option Argument Description

--help

(-h)

None

--config

(-c)

--httpks

(-j)

--consoleproxyks

(-p)

--responses

(-r) full pathname to the cell's global.properties

file

None

None full pathname to the cell's responses.properties

file

Provides a summary of available commands in this category.

Defaults to

$VCLOUD_HOME/etc/global.prop

erties

.

Generate a keystore file named certificates

for use by the http endpoint.

Generate a keystore file named proxycertificates

for use by the console proxy endpoint.

Defaults to

$VCLOUD_HOME/etc/responses.p

roperties

.

60 VMware, Inc.

Chapter 5 Cell Management Tool Reference

Table 5

4. Cell Management Tool Options and Arguments, certificates Subcommand (Continued)

Option

--keystore

(-s)

--keystore-pwd

(-w)

Argument

keystore-pathname keystore-password

Description

Full pathname to a JCEKS keystore containing the signed certificates.

Password for the JCEKS keystore referenced by the --keystore option.

Example: Replacing Certificates

You can omit the --config and --responses options unless those files were moved from their default locations. In this example, a keystore at

/tmp/my-new-certs.ks

has the password kspw

. This example replaces the cell's existing http endpoint certificate with the one found in

/tmp/my-new-certs.ks

[root@cell1 /opt/vmware/vcloud– director/bin]#

./cell-management-tool certificates -j -s /tmp/my-new-certs.ks -w kspw

Certificate replaced by user specified keystore at /tmp/new.ks.

You will need to restart the cell for changes to take effect.

N

OTE

You must restart the cell after you replace the certificates.

Generating Self-Signed SSL Certificates

Use the generate-certs command of the cell management tool to generate new self-signed SSL certificates for the cell.

The generate-certs command of the cell management tool automates the procedure shown in

“Create a

Self-Signed SSL Certificate,” on page 21.

To generate new self-signed SSL certificates and add them to a new or existing keystore, use a command line with the following form: cell-management-tool generate-certs options

Table 5

5. Cell Management Tool Options and Arguments, generate-certs Subcommand

Option Argument Description

--help

(-h)

None

--expiration

(-x)

--issuer

(-i)

--httpcert

(-j)

days-until-expiration

name=value [,

name=value, ...]

None

Provides a summary of available commands in this category.

Number of days until the certificates expire. Defaults to 365

X.509 distinguished name of the certificate issuer. Defaults to

CN=FQDN

. where FQDN is the fullyqualified domain name of the cell or its IP address if no fullyqualified domain name is available. If you specify multiple attribute and value pairs, separate them with commas and enclose the entire argument in quotation marks.

Generate a certificate for the http endpoint.

VMware, Inc. 61

vCloud Director Installation and Upgrade Guide

Table 5

5. Cell Management Tool Options and Arguments, generate-certs Subcommand (Continued)

Option

--key-size

(-s)

--keystore-pwd

(-w)

--out

(-o)

--consoleproxycert

(-p)

Argument

key-size keystore-password keystore-pathname

None

Description

Size of key pair expressed as an integer number of bits. Defaults to

2048. Note that key sizes smaller than 1024 are no longer supported per NIST Special Publication

800-131A.

Password for the keystore on this host.

Full pathname to the keystore on this host.

Generate a certificate for the console proxy endpoint.

N

OTE

To maintain compatibility with previous releases of this subcommand, omitting both -j and -p has the same result as supplying both -j and -p.

Example: Creating Self-Signed Certificates

Both of these examples assume a keystore at

/tmp/cell.ks

that has the password kspw

. This keystore is created if it does not already exist.

This example creates the new certificates using the defaults. The issuer name is set to

CN=Unknown

. The certificate uses the default 2048-bit key length and expires one year after creation.

[root@cell1 /opt/vmware/vclouddirector/bin]#

./cell-management-tool generate-certs -j -p -o /tmp/cell.ks -w kspw

New keystore created and written to /tmp/cell.ks.

This example creates a new certificate for the http endpoint only. It also specifies custom values for key size and issuer name. The issuer name is set to

CN=Test, L=London, C=GB

. The new certificate for the http connection has a 4096 bit key and expires 90 days after creation. The existing certificate for the console proxy endpoint is unaffected.

[root@cell1 /opt/vmware/vclouddirector/bin]#

./cell-management-tool generate-certs -j -o /tmp/cell.ks -w kspw

-i "CN=Test, L=London, C=GB" -s 4096 -x 90

New keystore created and written to /tmp/cell.ks.

Managing the List of Allowed SSL Ciphers

Use the ciphers command of the cell management tool to configure the set of cipher suites that the cell offers to use during the SSL handshake process.

When a client makes an SSL connection to a vCloud Director cell, the cell offers to use only those ciphers that are configured on its default list of allowed ciphers. Several ciphers are not on this list, either because they are not strong enough to secure the connection, or because they are known to contribute to SSL connection failures. When you install or upgrade vCloud Director, the installation or upgrade script examines the cell's certificates. If any of the certificates are encrypted using a cipher that is not on the list of allowed ciphers, the script modifies the cell's configuration to allow use of that cipher and displays a warning. You can continue using the existing certificates despite their dependence on these ciphers, or you can take the following steps to replace the certificates and reconfigure the list of allowed ciphers:

1 Create new certificates that do not use any of the disallowed ciphers. You can use cell-managementtool ciphers -a

as shown in “Example: List All Allowed Ciphers,” on page 63 to list all the ciphers

that are allowed in the default configuration.

62 VMware, Inc.

Chapter 5 Cell Management Tool Reference

2 Use the cell-management-tool certificates

command to replace the cell's existing certificates with the new ones.

3 Use the cell-management-tool ciphers

command to reconfigure the list of allowed ciphers to exclude any ciphers not used by the new certificates. Excluding these ciphers can make it faster to establish an

SSL connection to the cell, since the number of ciphers offered during the handshake is reduced to the practical minimum.

I

MPORTANT

Because the VMRC console requires the use of the AES256-SHA and AES128-SHA ciphers, you cannot disallow them if your vCloud Director clients use the VMRC console.

To manage the list of allowed SSL ciphers, use a command line with the following form: cell-management-tool ciphers options

Table 5

6. Cell Management Tool Options and Arguments, ciphers Subcommand

Option Argument Description

--help

(-h)

None

--all-allowed

(-a)

--compatible-reset

(-c)

--disallow

(-d)

None

None

Provides a summary of available commands in this category.

List all allowed ciphers.

Reset to default list of allowed ciphers, and also allow ciphers used by this cell's certificates.

Disallow the ciphers in specified comma-separated list.

--list

(-l)

--reset

(-r)

Comma-separated list of cipher names, as published at http://www.openssl.o

rg/docs/apps/ciphers.

html

None

None

List currently configured ciphers.

Reset to default list of allowed ciphers. If this cell's certificates use disallowed ciphers, you will not be able to make an SSL connection to the cell until you install new certificates that use an allowed cipher.

Example: List All Allowed Ciphers

Use the --all-allowed (-a) option to list all the ciphers that the cell is currently allowed to offer during an

SSL handshake.

[root@cell1 /opt/vmware/vcloud-director/bin]#

./cell-management-tool ciphers –a

* TLS_DHE_DSS_WITH_AES_256_CBC_SHA

* TLS_DHE_DSS_WITH_AES_128_CBC_SHA

* TLS_DHE_DSS_WITH_3DES_EDE_CBC_SHA

* TLS_DHE_RSA_WITH_AES_256_CBC_SHA

* TLS_DHE_RSA_WITH_AES_128_CBC_SHA

* TLS_DHE_RSA_WITH_3DES_EDE_CBC_SHA

* TLS_RSA_WITH_AES_256_CBC_SHA

* TLS_RSA_WITH_AES_128_CBC_SHA

* TLS_RSA_WITH_3DES_EDE_CBC_SHA

* TLS_ECDHE_ECDSA_WITH_AES_256_CBC_SHA

* TLS_ECDHE_ECDSA_WITH_AES_128_CBC_SHA

VMware, Inc. 63

vCloud Director Installation and Upgrade Guide

* TLS_ECDHE_ECDSA_WITH_3DES_EDE_CBC_SHA

* TLS_ECDHE_RSA_WITH_AES_256_CBC_SHA

* TLS_ECDHE_RSA_WITH_AES_128_CBC_SHA

* TLS_ECDHE_RSA_WITH_3DES_EDE_CBC_SHA

* TLS_ECDH_ECDSA_WITH_AES_256_CBC_SHA

* TLS_ECDH_ECDSA_WITH_AES_128_CBC_SHA

* TLS_ECDH_ECDSA_WITH_3DES_EDE_CBC_SHA

* TLS_ECDH_RSA_WITH_AES_256_CBC_SHA

* TLS_ECDH_RSA_WITH_AES_128_CBC_SHA

* TLS_ECDH_RSA_WITH_3DES_EDE_CBC_SHA

* SSL_RSA_WITH_3DES_EDE_CBC_SHA

* SSL_DHE_DSS_WITH_3DES_EDE_CBC_SHA

Example: Disallow Two Ciphers

Use the --disallow (-d) option to remove one or more ciphers from the list of allowed ciphers. This option requires at least one cipher name. You can supply multiple cipher names in a comma-separated list. You can obtain names for this list from the output of ciphers –a

. This example removes two ciphers listed in the previous example.

[root@cell1 /opt/vmware/vclouddirector/bin]#

./cell-management-tool ciphers –d

SSL_DHE_RSA_WITH_3DES_EDE_CBC_SHA,SSL_DHE_DSS_WITH_3DES_EDE_CBC_SHA

Configuring the Metrics Database Connection

Use the configure-metrics command of the cell management tool to connect the cell to the optional metrics database.

vCloud Director can collect metrics that provide current and historic information about virtual machine performance and resource consumption. Data for historic metrics is stored in a KairosDB database backed by Cassandra. See

Chapter 6, “Install and Configure Optional Database Software to Store and Retrieve

Historic Virtual Machine Performance Metrics,” on page 67.

To create a connection from KairosDB to a vCloud Director, use a command line with the following form: cell-management-tool configure-metrics options

Table 5

7. Cell Management Tool Options and Arguments, configure-metrics Subcommand

Command Argument Description

--help

(-h)

None

--repository-host

--repository-port

Host name or IP address of

KairosDB host

KairosDB port to use.

Provides a summary of available commands in this category.

If you have multiple installations of KairosDB, you must supply the load-balancer address here.

By default, KairosDB listens on port 8080.

64 VMware, Inc.

Chapter 5 Cell Management Tool Reference

Example: Configuring a Metrics Database Connection

This example configures system to use a KairosDB instance hosted at IP address 10.0.0.1 at the default port.

The address can be either the address of a single machine running a single instance of KairosDB, or the address of a load balancer that distributes requests to multiple installations of KairosDB.

[root@cell1 /opt/vmware/vclouddirector/bin]#

./cell-management-tool configure-metrics --repository-host 10.0.0.1 --repository-port 8080

Recovering the System Administrator Password

If you know the vCloud Director database username and password, you can use the recover-password command of the cell management tool to recover the vCloud Director system administrator password.

With the recover-password command of the cell management tool, a user who knows the vCloud Director database username and password can recover the vCloud Director system administrator password.

To recover the system administrator password, use a command line with the following form: cell-management-tool recover-password options

Table 5

8. Cell Management Tool Options and Arguments, recover-password Subcommand

Option Argument Description

--help

(-h)

None

--dbuser

--dbpassword

The user name of the vCloud Director database user.

The password of the vCloud Director database user.

Provides a summary of available commands in this category.

Must be supplied on the command line.

Prompted for if not supplied.

Force Running Tasks to Complete

Use the fail-tasks command of the cell management tool to generate a list of tasks running on a quiesced cell that you can force to complete immediately with a status of failure.

When you quiesce a cell using the cell-management-tool -q

command, running tasks should terminate gracefully within a few minutes. If tasks continue to run on a cell that has been quiesced, the superuser can force those tasks to exit with failure so that system maintenance can begin.

To generate a list of running tasks that can be forced to fail, use a command line with the following form: cell-management-tool fail-tasks -m "message"

Table 5

9. Cell Management Tool Options and Arguments, fail-tasks Subcommand

Command Argument Description

--help

(-h)

None

--message

(-m) Message text.

Provides a summary of available commands in this category.

Message text to place in task completion status.

VMware, Inc. 65

vCloud Director Installation and Upgrade Guide

Example: Fail Tasks Running on the Cell

This example generates a list of tasks running on this cell that are candidates for forced failure and requests confirmation that the tasks should be forced to fail.

[root@cell1 /opt/vmware/vclouddirector/bin]#

./cell-management-tool fail-tasks -m "administrative shutdown"

Operation: IMPORT_SINGLETON_VAPP, Start time: 12/16/13 6:41 PM, Username: system, Organization: org1

Would you like to fail the tasks listed above?

Type

y

to fail the task with a failure status of administrative shutdown. Type

n

to allow the task to continue running.

N

OTE

If multiple tasks are returned in the response, you must decide to fail all of them or take no action.

You cannot choose a subset of tasks to fail.

66 VMware, Inc.

Install and Configure Optional

Database Software to Store and

Retrieve Historic Virtual Machine

Performance Metrics

6

vCloud Director can collect metrics that provide current and historic information about virtual machine performance and resource consumption for the virtual machines that are in your cloud. Data for historic metrics is stored in a KairosDB database backed by a Cassandra cluster.

Cassandra and KairosDB are open source databases that, when deployed together, provide a scalable, highperformance solution for collecting time series data like virtual machine metrics. If you want your cloud to support retrieval of historic metrics from virtual machines, you must install and configure Cassandra and

KairosDB, then use the cell-management-tool

utility to connect vCloud Director to KairosDB. Retrieval of current metrics does not require optional database software.

To support retrieval of historic metrics, vCloud Director requires a Cassandra cluster. A Cassandra cluster consists of one or more machines on which you have installed Cassandra and are running the Cassandra service. For a typical vCloud Director installation, you should have at least three machines in the Cassandra cluster. Because the vCloud Director metrics monitoring feature uses a replication factor of two, having three machines, the nodes, in the Cassandra cluster ensures that a node is always available to handle a transaction. You can use a single Cassandra cluster for your vCloud Director installation.

You also need at least one instance of KairosDB configured to work with your Cassandra cluster. If your cloud collects historic metrics from many virtual machines, additional instances of KairosDB might be needed. You can either install and configure KairosDB on one of the Cassandra nodes and point the cell management tool to that endpoint, or install and configure KairosDB on each Cassandra node, add a load balancer in front of the configuration, and point the cell management tool at the load balancer endpoint.

Because vCloud Director expects to communicate with KairosDB at a single IP address, installations that include multiple instances of KairosDB must use a load balancer to provide that address and distribute vCloud Director requests to the KairosDB instances.

Prerequisites

n n n n n

Verify that vCloud Director is installed and running before you configure the optional database software.

If you are not already familiar with Cassandra and KairosDB, review the material available at http://cassandra.apache.org/ and https://code.google.com/p/kairosdb/ .

Obtain either Cassandra 1.2.x or Cassandra 2.0.x from http://cassandra.apache.org/download/ .

Obtain KairosDB 0.9.1 from https://code.google.com/p/kairosdb/ .

Complete the installation and configuration of the Cassandra cluster that you plan to use with your vCloud Director installation, according to this configuration: n

Cassandra 1.2.x or Cassandra 2.0.x is installed on at least three machines that are connected to the same network that your vCloud Director cells use.

n

The machines are configured to have their own physical storage, and not shared storage.

VMware, Inc. 67

vCloud Director Installation and Upgrade Guide n n n n n

The machines are configured as a Cassandra cluster.

Java Native Access (JNA) version 3.2.7 or later is enabled for the Cassandra cluster, to improve performance of memory usage and disk access.

Complete the installation and configuration of at least one instance of KairosDB 0.9.1 on one of the

Cassandra nodes, to use your Cassandra cluster as its database. You can also install and configure

KairosDB on each Cassandra node if you add a load balancer in front of that configuration.

Verify that KairosDB and Cassandra are configured correctly. Use a Web browser to browse to http://KairosDB-IP:8080/api/v1/metricnames

. If the page opens without an error, KairosDB and

Cassandra are configured correctly.

Verify that you can run the service

command of the cell-management-tool

utility. For details about the service

command, see “Start or Stop vCloud Director Services,” on page 36.

Procedure

1 Use the cell-management-tool

utility to configure a connection between vCloud Director and KairosDB.

Use a command like this, where KairosDB-IP is the IP address of the machine on which you installed

KairosDB, or the IP address of the load balancer you are using to distribute requests to multiple instances of KairosDB.

[root@cell1 /opt/vmware/vcloud-director/bin]#

./cell-management-tool configure-metrics

--repository-host KairosDB-IP --repository-port 8080

2 Restart each vCloud Director cell using the service

command of the cell-management-tool

utility.

68 VMware, Inc.

Index

A

AMQP broker, to install and configure 25

architecture diagram 7

B

browsers, supported 11

C

cell management tool

cell command 56

certificates command 60

ciphers command 62

configure-metrics command 64

dbextract command 57

fail-tasks command 65

generate-certs command 61

options 55

certificate

self-signed 21

signed 18

configuration, confirm settings and complete 53

D

database

about 15

connection details 30

corrupted scheduler data 60

Oracle 15

SQL Server 16

supported platforms 9

to upgrade 45

databases, optional 67

F

firewall, ports and protocols 14

G

guest customization, preparing 35

H

host, to upgrade 48

I

installation

about 5

and capacity planning 8

architecture diagram 7

VMware, Inc.

creating a server group 27

of first server 28

of more servers 34

overview of 7

to configure 51

uninstalling 37

Installation ID, to specify 52

J

Java, required JRE version 11

K

keystore 17

L

license agreement 52

M

Microsoft Sysprep 35

N

network

configuration requirements 13

security of 14

NSX Manager

installing and configuring 24

supported releases 9

to upgrade 47

P

product serial number

to enter 52 to obtain 52

R

RPM file, to verify digital signature 25

S

services, to start 36

System Administrator account

to create 52

to recover password 65

System Name, to specify 52

69

vCloud Director Installation and Upgrade Guide

U

upgrade

database 45

of first server 43

upgrading, workflows for 39

V

vCenter, supported releases 9

vCenter Server, to upgrade 48

vShield Manager

installing and configuring 23

supported releases 9

to upgrade 47

70 VMware, Inc.

advertisement

Key Features

  • vCloud Director Installation
  • vCloud Director Upgrade
  • vCloud Director Configuration
  • Integration with VMware vCenter
  • vCloud Director Server Group
  • Database Configuration
  • SSL Certificate Creation
  • Network and Database Connection Configuration

Frequently Answers and Questions

What is vCloud Director?
VMware vCloud Director is a software platform that enables the creation, management and automation of private and hybrid clouds. It provides a centralized point of control for managing virtual machines, networks, storage and other cloud resources.
What are the system requirements for vCloud Director 5.6?
The system requirements for vCloud Director 5.6 are outlined in the document. They include specific requirements for the operating system, memory, disk space, database, and network configuration. Refer to the document for detailed information.