4 Power Supplies
Power Supplies
4
Sola/Hevi-Duty has a broad range of standard power
supplies to suit almost any industrial application. Updated
approvals and user friendly features make power system
design easy. The product line includes one of the
broadest ranges of DIN Rail and linear-based power
supplies in the marketplace. The DIN Rail products feature
full CE compliance (including all the elements of CE design
engineers need to worry about: safety/LVD, EMC, and
ingress protection). UL 508 approvals eliminate derating in
UL 508 listed panel systems. Global inputs are available
for installations around the world.
Sola/Hevi-Duty also offers a three phase input option on
many of the SDN DIN Rail products that convert 380/480
three phase directly to 24 VDC. They provide extremely
stable, regulated low voltage without the need for a step
down transformer saving space and money. For the
popular SL linear line, Sola/Hevi-Duty leads the market
by replacing the time consuming solder connections with
screw terminals. Ease-of-use is now combined with the
economy and extremely low noise.
Linear vs. Switcher
Sola/Hevi-Duty has provided both linear and switching
technology products for many years. As a leading
supplier of power products to the industrial market, both
technologies are still important. Switching technology
(most of Sola’s DIN Rail line) is the predominant method of
AC-DC conversion for almost any type of electronic system
sold today in the world, from PLC’s to desktop PC’s.
Linear Power Supplies for a broad range of applications.
The small size, lightweight and high efficiency of the
switching products give them significant advantages over
the linear technology products (Sola’s SL and 83 series).
Sola/Hevi-Duty switching products provide well filtered and
regulated DC of typically less than 1% deviation from the
nominal output voltage.
Linears are about 50% efficient while their switching
counterparts are typically over 80% efficient. Switchers
are light enough to mount on a DIN Rail, while only the
smallest linears are capable of being securely mounted to
a DIN Rail. Linears are still popular today because they
do provide very tight regulation (<.01% typically), almost
perfectly clean DC, fast transient response and their low
component count helps provide a lower material cost for
its user. Linears are typically open frame because of the
excessive heat dissipation from their low efficiency.
Sola/Hevi-Duty’s industry standard linears, however, are
available with optional covers for safety. Most linears are
recognized to UL 60950 and cannot meet the stricter
temperature requirements of the UL 508 Listing, such as
with Sola/Hevi-Duty’s DIN Rail power supplies.
Linear vs. Switcher
Visit our website at www.solaheviduty.com or
Contact Technical Services at (800) 377-4384 with any questions.
83
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
4
Power Supplies
DC Power Supply Selection Process
Power supplies can be selected online by visiting our
website. Enter your power requirements and a list of
matching power supplies will list. You can also manually
select a power supply by following the directions below:
1) Gather the required information.
• Input voltage and frequency?
• Wattage needed?
• Number of outputs?
• Voltage of each output?
• Amperage of each output?
• Don’t forget to take into account the peak
loading of each output.
2) Calculate the power (wattage) of the DC power
supply you need. If more than one output is required,
do the following calculation:
• Multiply the Voltage times the amperage of
each output to calculate the wattage of each
output. Next, add together the wattage of
each output to get the total wattage for the
supply.
Selection Worksheet
Input: ________ V ________ Hz
Output:
_______ VDC x _______ Amps = ________ Watts
_______ VDC x _______ Amps = ________ Watts
_______ VDC x _______ Amps = ________ Watts
_______ VDC x _______ Amps = ________ Watts
_______ VDC x _______ Amps = ________ Watts
_______ VDC x _______ Amps = ________ Watts
_______ VDC x _______ Amps = ________ Watts
_______ VDC x _______ Amps = ________ Watts
(Add Watts from each output to calculate)
Total Watts = ________
Physical Dimensions:
_______H x _______W x _______D
3) Determine which models from the Power Supply
Selection Chart (on the next page) meet all of the
required specifications.
Mounting:
_______ DIN Rail
_______ Chassis
_______ Other
4) Download the specifications sheets from our web
site (www.solaheviduty.com).
Other required features or options:
5) Check the mounting style, connections and physical
size of the power supply to ensure its suitability for the
intended application.
6) Check for applicable safety approvals for the country
and application the power supply will be used in.
Try our online product selector at
www.solaheviduty.com/psselect.
Enter your power requirements and a
list of matching power supplies will list.
It’s fast and easy.
84
If you have filled out this form and cannot find the
appropriate power supply, please fax (800-367-4384) or
e-mail ([email protected]) this information to the
Technical Services group.
Visit our website at www.solaheviduty.com or
contact Technical Services at (800) 377-4384 with any questions.
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
4
Power Supplies
Power Supply Selection Table
This chart is intended only as a guide for selecting a series of DC power supply, some of the
series listed may not work in all applications.
Input Voltage
Series
Output Voltage
DC
115
VAC
230
VAC
380/480
VAC
SDN™
X
X
X
X
SDP™
X
X
X
SCP
X
X
X
SCD
3.3 V
5V
12 V
15 V
24 V
48 V
X
X
X
Power
Range
(Total
Watts)
Number of Outputs
Single
- Din Rail mount compact
98
- Din Rail mount/Chassis
103
- Din Rail mount/Chassis
- DC input
105
- Din Rail mount/Chassis
101
- Din Rail mount
- Adjustable Pot, Red or UPS
option
107
- 40 - 110 Watt, open frame,
molex type connections.
- 200 Watt, enclosed with
connected screw terminals
116
X
15 - 100
X
X
X
X
X
X
30
X
X
X
X
X
X
X
30
X
X
4 - 10
X
X
75 - 600
X
40 - 200
X
X
X
X
SCL
X
X
SFL
X
X
GL
OEM
Switchers
X
X
X
X
X
X
SMP
X
X
X
X
X
X
X
250-1000
X
X
X
X
SHP
X
X
X
X
X
X
X
15002000
X
X
X
X
Silver Line
Linears
X
X
X
X
X
X
15 - 244
X
X
X
X
X
X
X
Page
86
X
X
Notes
- DIN Rail mount
- 3 Phase input available.
- Redundant options.
- NEC Class 2/DeviceNetTM
X
X
>4
X
X
X
Triple
60 - 960
X
X
Dual
X
- Modular design
- Screw Terminals (OEM) supply
- Configurable Voltage
Output
- Industry standard footprint.
Screw terminals and optional
covers.
119
124
110
DIN Rail Selection Guide
Output Voltages
1
2.5
3
48
24
SDP1-48-100T
SDP06-24-100T
SDP1-24-100T
SFL1.5-48-100
SFL3-48-100
5
12
SCP30S15-DN
±12
5/24
5/12/12
SCL4D15-DN
SCL4D12-DN
SCP30D524-DN
SCP30S524B-DN
SCL10T512-DN
SDP2-12-100T
SCL10D15-DN
SCL10D12-DN
SCP30S12B-DN
SCP30D15-DN
SCP30D12-DN
SDP3-15-100T
10
5
±15
SCP30T512-DN
SDP2-12-100T
SDN4-24-100LP
SDP4-24-100LT
4
A
M
P
S
SDN2.5-24-100P
SDP2-24-100T
15
SFL6-48-100
SDN5-24-100P
SDN5-24-480 (3Ø)
SFL6-12-100
SDP5-5-100T
SCP30S5B-DN
7.2
SDN10-24-100P
SDN10-24-480 (3Ø)
10
12
20
SFL12-48-100
SFL12-24-100
SDN20-24-100P
SDN20-24-480C (3Ø)
25
SFL24-24-100
30
SDN30-24-480 (3Ø)
40
SDN40-24-480 (3Ø)
Visit our website at www.solaheviduty.com or
Contact Technical Services at (800) 377-4384 with any questions.
85
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
4
Power Supplies
SDN™ Performance DIN Rail Series
The SDN DIN Rail power supplies provide industry
leading performance. Sag immunity, transient suppression
and noise tolerant, the SDN series ensures compatibility in
demanding applications. Power factor correction to meet
European directive, hazardous location approvals and
optional redundant accessories allow the SDN series to
be used in a wide variety of applications. Wide operation
temperature range, high tolerance to shock and vibration
and reliable design make the SDN series the definition of
DC power quality.
Features
• Power Factor Correction (per EN61000-3-2)
UL 508 Listed
IND. CONT. EQ.
E61379
• Auto Select 115/230 VAC, 50/60 Hz Input
UL 60950
E137632
CUL/CSA-C22.2
No. 234-M90
EMC and
Low Volt.
Directive
• Single Phase models meet SEMI F47 Sag Immunity
• Class 1, Div 2 Hazardous Locations
• ATEX approval on 2.5 through 10A Single Phase
Models
• Improved metal mounting clip
• DC OK Signal
Related Products
•
•
•
•
SDP™ Series
SFL Series
SCP Series
SCL Series
• Adjustable Voltage
• SDN10-24-100P New Compact width (3.26”)
• Parallel Capability standard on all units
• Industrial grade design
• -10°C to 60°C operation without derating.
Indefinite short circuit, overvoltage and
overtemperature protection.
• Powers high inrush loads without shutdown
or foldback
• Rugged metal case and DIN connector
• SDN2.5-24-100P and SDN4-24-100LP meet NEC
Class 2
• Narrow width on rail for space critical applications
• User-friendly front panel
• Large, rugged, accessible, multiple connection
screw terminations
• Easy installation
• Broad range of product to fit almost any
application – 2.5 A through 40 A
• Single and three phase inputs available
• Highly efficient >90% switching technology
• High MTBF and reliability
86
Applications
•
•
•
•
•
•
•
•
•
Industrial/Machine control
Process control
Conveying Equipment
Material Handling
Vending Machines
Packaging Equipment
DeviceNetTM
Amusement Park Equipment
Semiconductor Fabrication Equipment
Accessories
• Chassis Mount Bracket (SDN-PMBRK2)
Visit our website at www.solaheviduty.com or
contact Technical Services at (800) 377-4384 with any questions.
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
4
Power Supplies
The Sola Difference
Strong all metal
DIN connector
for horizontal or
vertical mounting
Rugged metal packaging
Large, heavy-duty screw
terminals for #10 AWG/4 mm2,
for quick, easy installation
Multiple output
connections
for ease of wiring
multiple devices
DC OK Signal
Single or parallel use
selectable by user
Easy to use, clearly
labeled front panel
Adjustable
output voltage
No internal fan, no extra
cooling required in any
power level
UL508 listing
means no derating
in UL 508 systems
Full CE compliance for
safety, emissions and
ingress protection
Automatically adjusts for
either 115 or 230V, 50 or
60 Hz Input. No manual
intervention required.
Narrow width for minimal
panel space required
Visit our website at www.solaheviduty.com or
Contact Technical Services at (800) 377-4384 with any questions.
87
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
4
Power Supplies
SDNTM Specifications (Single Phase)
Description
Catalog Number
SDN 2.5-24-100P
SDN 4-24-100LP
SDN 5-24-100P
SDN 10-24-100P
SDN 20-24-100P
Input
Nominal Voltage
115/230 VAC auto select
-AC Range
85-132/176-264 VAC
-DC Range6
90-375 VDC
210-375 VDC
-Frequency
N/A
47 - 63 Hz
Nominal Current1
-Inrush current max.
Efficiency (Losses2)
1.3 A. / 0.7 A
2.1 A / 1.0 A
typ. < 25 A
2.2 A / 1.0 A
5 A / 2 A typ.
typ. < 20 A
> 87.5% typ (8.6 W)
> 88% typ (13.1 W)
> 88% typ (16.4 W)
Power Factor Correction
9 A/ 3.9 A
typ. < 40 A
> 88% typ (32.7 W)
> 90% typ (48 W)
Units Fulfill EN61000-3-2
Output
Nominal Voltage
24 VDC (22.5 - 28.5 VDC adj.)
-Tolerance
24 VDC (22.5 - 28.5 VDC adj.)
24 VDC (22.5 - 25.5 VDC adj.)
< ±2% overall (combination Line, load, time and temperature related changes)
-Ripple3
< 50 mVpp
Nominal Current
2.5 A (60 W)
-Peak Current
1.6x Nominal Current
< 2 sec.
4
-Current Limit
Holdup Time5
Parallel Operation
3.8 A (92 W)
5 A (120 W)
10 A (240 W)
20 A (480 W)
4.2 A max at 23.8V
6 A 2x Nominal Current
< 2 sec.
12 A 2x Nominal Current
< 2 sec.
25 A 2x Nominal Current
< 2 sec.
Fold Forward (Current rises, voltage drops to maintain constant power during overload up to max peak current)
> 50 ms
> 100 ms
> 100 ms
> 20 ms
Single or Parallel use is selectable via Front Panel Switch (SDN4 should not be used in parallel as Class 2 rating would be violated.)
General
EMC:
-Emissions
EN61000-6-3, -4; Class B EN55011, EN55022 Radiated and Conducted including Annex A.
-Immunity
EN61000-6-1, -2; EN61000-4-2 Level 4, EN61000-4-3 Level 3; EN61000-4-6 Level 3; EN61000-4-4 Level 4 input and Level 3 output; EN61000-4-5 Isolation Class
4, EN61000-4-11; Transient resistance according to VDE 0160/W2 over entire load range.
Approvals
Temperature
MTBF:
EN60950; EN50178; EN60204; UL508 Listed, cULus; UL60950, cRUus, CE (LVD 73/23 & 93/68/EEC). EN61000-3-2, IEC60079-15 (Class 1, Zone 2, Hazardous
Location, Groups A, B, C, D w/ T3A temp class up to 60°C Ambient.) SEMI F47 Sag Immunity. SDN2.5 & SDN4 - UL60950 testing to include approval as
Class 2 power supply.
Storage: -25oC...+85oC Operation. -10o-60oC full power with operation to 70oC possible with a linear derating to half power from 60oC to 70oC (Convection cooling,
no forced air required). Operation up to 50% load permissable with sideways or front side up mounting orientation. The relative humidity is < 90% RH,
noncondensing; IEC 68-2-2, 68-2-3. For operation below -10oC, contact Technical Services.
> 820,000 hours
- Standard
> 640,000 hours
Warranty
General Protection/Safety
> 600,000 hours
Bellcore Issue 6 Method 1 Case 3 @ 40C
> 510,000 hours
MIL217F @ 30C
5 years
Protected against continuous short-circuit, overload, open-circuit. Protection class 1 (IEC536), degree of protection IP20 (IEC 529)
Safe low voltage: SELV (acc.EN60950)
Status Indicators
Green LED and DC OK signal (N.O. Solid State Contact rated 200 mA / 60 VDC)
Installation
Fusing
-Input
Internally fused. External 10 A slow acting fusing for the input is recommended to protect input wiring.
-Output
Outputs are capable of providing high currents for short periods of time for inductive load startup or switching. Fusing may be required for wire/loads if 2x Nominal
O/P current rating cannot be tolerated. Continuous current overload allows for reliable fuse tripping.
Mounting
Connections
Simple snap-on system for DIN Rail TS35/7.5 or TS35/15 or chassis-mounted (optional screw mounting set SDN-PMBRK2 required).
Input: IP20-rated screw terminals, connector size range: 16-10 AWG (1.5-6 mm2) for solid conductors. 16-12 AWG (0.5-4 mm2) for flexible conductors.
Output: Two connectors per output, connector size range: 16-10 AWG (1.5 - 6 mm2) for solid conductors.
Case
-Free Space
H x W x D (inches/mm)
Weight (lbs/g)
1
2
3
88
Fully enclosed metal housing with fine ventilation grid to keep out small parts.
25 mm above and below, 25 mm left and right,
10 mm in front
25 mm above and below, 25 mm
left and right, 15 mm in front
70 mm above and below, 25 mm left and right,
15 mm in front
4.88 in. x 1.97 in. x 4.55 in.
(124 mm x 50 mm x 116 mm)
4.88 in. x 2.56 in. x 4.55 in.
(124 mm x 65 mm x 116 mm)
4.88 in. x 3.26 in. x 4.55 in.
(124 mm x 83 mm x 116 mm)
4.88 in. x 6.88 in. x 4.55 in.
(124 mm x 175 mm x 116 mm)
1 lb (460g)
1.5 lbs (620g)
2.2 lbs (1100g)
3 lbs (1520g)
Input current ratings are conservatively specified with low input, worst case efficiency and power factor.
Losses are heat dissipation in watts at full load, nominal input line.
Ripple/noise is stated as typical values when measured with a 20 MHz, bandwidth scope and 50 Ohm resistor.
4
5
6
All peak current is calculated at 24 Volt levels.
Full load, 100 VAC Input @ Tamb = +25°C
Not UL listed for DC input.
Visit our website at www.solaheviduty.com or
contact Technical Services at (800) 377-4384 with any questions.
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
4
Power Supplies
SDNTM Specifications (Three Phase)
Description
Catalog Number
SDN 5-24-480
SDN 10-24-480
SDN 20-24-480C
SDN 30-24-480
SDN 40-24-480
Input
Nominal Voltage
1Ø or 3Ø 380-480 VAC
1Ø or 3Ø 380 - 480 VAC1
-AC Range
340 - 576 VAC
-DC Range
450 - 820 VDC
-Frequency
Nominal Current
47 - 63 Hz
0.5 A
0.8 A
-Inrush current max.
Efficiency (Losses) 3
3Ø 380 - 480 VAC
1.5 A
2.0 A
typ. < 18 A
> 90% typ (12 W)
3.0 A
typ. < 30 A
> 90% typ (48 W)
> 90% typ (72 W)
> 90% typ (96 W)
Units Fulfill EN61000-3-2
Power Factor Correction
Output
Nominal Voltage
24 VDC (22.5 - 28.5 VDC adj.)
-Tolerance
< ±2% overall (combination Line, load, time and temperature related changes)
-Ripple4
< 50 mVpp
Nominal Current
5 A (120 W)
10 A (240 W)
20 A (480 W)
30 A (720 W)
40 A (960 W)
-Peak Current
6 A 2x Nominal Current <2sec.
12 A 2x Nominal Current <2 sec.
25 A 2x Nominal Current <2sec.
35 A 2x Nominal Current < 2 sec.
45 A 2x Nominal Current<2 sec
-Current Limit
Fold Forward (Current rises, voltage drops to maintain constant power during overload up to max peak current)
Holdup Time
Parallel Operation
> 40 ms
> 28 ms
> 20 ms
5A through 30A units may be passively paralleled by selecting the “P” position of the switch on the unit. The SDN40 contains active current balancing.
General
EMC
- Emissions
-Immunity
Approvals
Temperature
MTBF
EN61000-6-3, -4; Class B EN55011, EN55022 Radiated and Conducted including Annex A.
EN61000-6-1, -2; EN61000-4-2 Level 4, EN61000-4-3 Level 3; EN61000-4-6 Level 3; EN61000-4-4 Level 4 input and Level 3 output; EN61000-4-5 Isolation Class 4,
EN61000-4-11; Transient resistance according to VDE 0160/W2 over entire load range.
CB Scheme, EN60950; EN50178; EN60204; UL508 Listed, cULus; UL60950, cRUus, CE (LVD 73/23 & 93/68/EEC). EN61000-3-2, IEC 60079-15 (Class 1, Zone 2
hazardous location, Groups IIA, IIB, IIC w/T3 temp class up to 60°C Ambient.
Storage: -25oC...+85oC Operation. -10oC -60oC full power with operation to 70oC possible with a linear derating to half power from 60oC to 70oC (Convection cooling, no
forced air required). Operation up to 50% load permissable with sideways or front side up mounting orientation. The relative humidity is < 90% RH, noncondensing; IEC
68-2-2, 68-2-3.
> 1,110,000 hours
> 940,000 hours
> 550,000 hours
-Standard
MIL217F @ 30C
Warranty
5 years
> 620,000 hours
> 490,000 hours
General Protection/
Safety
Protected against continuous short-circuit, overload, open-circuit. Protection class 1 (IEC536), degree of protection IP20 (IEC 529) Safe low voltage: SELV (acc.EN60950)
Status Indicators
Green LED on when Vout = 18V or greater.
Installation
Fusing
-Input
-Output
Mounting
Connections
Internally fused.
Outputs are capable of providing high currents for short periods of time for inductive load startup or switching.
Fusing may be required for wire/loads if 2x Nominal O/P current rating cannot be tolerated. Continuous current overload allows for reliable fuse tripping.
Simple snap-on system for DIN Rail TS35/7.5 or TS35/15 or chassis-mounted (optional screw mounting set SDN-PMBRK2 required).
Input: IP20-rated screw terminals, connector size range: 16-10 AWG (1.5-6 mm2) for solid conductors. 16-12 AWG (0.5-4 mm2) for flexible conductors. Output: Two connectors per output, connector size range: 16-10 AWG (1.5-6 mm2) for solid conductors.5
Case
-Free Space
HxWxD
(inches/mm)
Weight (lbs/g)
1
2
3
4
5
Fully enclosed metal housing with fine ventilation grid to keep out small parts.
25 mm above and below, 25 mm left and right, 15 mm in front
70 mm above and below, 25 mm left and right , 15 mm in front
4.88 in. x 2.91 in. x 4.55 in.
(124 mm x 73 mm x 116 mm)
4.88 in. x 3.5 in. x 4.55 in.
(124 mm x 89 mm x 116 mm)
4.88 in. x 5.9 in. x 4.55 in.
(124 mm x 150 mm x 116 mm)
4.88 in. x 9.72 in. x 4.55 in.
(124 mm x 247 mm x 116 mm)
4.88 in. x 11.1 in. x 4.55 in.
(124 mm x 282 mmx 116 mm)
1.7 lbs (730g)
2.16 lbs (980g)
3.97 lbs (1800g)
4 lbs (2000g)
6.6 lbs (3300g)
For the SDN 20-24-480C, single phase input is permissable, but output is derated to 75% (15 Amps @ 24 VDC).
Input current ratings are conservatively specified with low input, worst case efficiency and power factor.
Losses are heat dissipation in watts at full load, nominal input line.
Ripple/noise is stated as typical values when measured with a 20 MHz, bandwidth scope and 50 Ohm resistor.
For the SDN 40-24-480, output: one (+) two (-) connectors, size range 16-5 AWG (1.5016 mm2) solid conductor.
Visit our website at www.solaheviduty.com or
Contact Technical Services at (800) 377-4384 with any questions.
89
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
4
Power Supplies
SDN™ Series Dimensions
D
W
+ +
OK
OK
Single
Parallel
H
S O LA
Power Supply
SDN 2.5-24-100P
U
L
H
W
D
SDN 2.5-24-100P
4.88 (124)
1.97 (50)
4.55 (116)
SDN 4-24-100LP
4.88 (124)
2.56 (65)
4.55 (116)
SDN 5-24-100P
4.88 (124)
2.56 (65)
4.55 (116)
SDN 5-24-480
4.88 (124)
2.91 (73)
4.55 (116)
SDN 10-24-100P
4.88 (124)
3.26 (83)
4.55 (116)
NEC Class 2
Power Supply
24-28 V
C
Dimensions - inches (mm)
Catalog Number
-
-
24 VDC / 2.5 A
���� ���� ��
����
US LISTED
115/230 VAC 1.3-0.7 A 50/60 HZ
N
L
W
D
S O LA
H
Power Supply
SDN 20-24-480C
���� ���� ��
����
Overload
Output:
24 VDC / 20 A
Electronically protected
Catalog Number
90
2428V
+ + - -
OK
Single Use
L1 L2 L3
Parallel Use
Input:
3PH 380/500 VAC
1.7/1.5A/Phase 50/60 Hz
Reset fuse mode
US LISTED
Fuse Mode
U
L
Continuous Mode
C
Dimensions - inches (mm)
H
W
D
SDN 20-24-100P
4.88 (124)
6.88 (175)
4.55 (116)
SDN 10-24-480
4.88 (124)
3.50 (89)
4.55 (116)
SDN 20-24-480C
4.88 (124)
5.90 (150)
4.55 (116)
SDN 30-24-480
4.88 (124)
9.72 (247)
4.55 (116)
SDN 40-24-480
4.88 (124)
11.10 (282)
4.55 (116)
Visit our website at www.solaheviduty.com or
contact Technical Services at (800) 377-4384 with any questions.
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
Power Supplies
4
SDN™ Series Mounting
DIN Rail Mounting
Snap on the DIN Rail:
1. Tilt unit slightly backwards
2. Put it onto the DIN Rail
3. Push downwards until stopped
4. Push at the lower front edge to lock
5. Shake the unit slightly to ensure that the retainer
has locked
Alternative Panel Mount: Using the optional SDN-PMBRK2
accessory, the unit can be screw mounted to a panel.
Detachment from DIN Rail:
Press button downwards (to unlock) and remove the unit
from the DIN Rail.
Chassis Mounting
Dimensions
Instead of snapping a Sola SDN™ unit on the DIN Rail,
you can also attach it using the screw mounting set
SDN-PMBRK2.
This set consists of two metal brackets, which replace the
existing two aluminum profiles.
Visit our website at www.solaheviduty.com or
Contact Technical Services at (800) 377-4384 with any questions.
91
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
4
Power Supplies
SDN™ DeviceNetTM Series
As a member of the Open DeviceNetTM Vendors
Association (ODVA), Sola/Hevi-Duty has designed two
power supplies specifically for DeviceNetTM applications.
Sola’s SDN DeviceNetTM models meet ODVA specifications
for power supplies for either Thin or Thick cable
applications.
The SDN4-24-100LP has the highest output current
possible while still meeting the requirements for NEC Class
2 and UL 1310. This is necessary for installations to meet
the National Electrical Code (NEC) or the Canadian Electric Code (CE code) without the need for secondary fusing.
The SDN10-24-100P is designed for installations that
utilize the Full 8A capability of the Thick Cable system.
Note – local codes may prohibit the use of the full capacity
of the power supply.
Features (General)
• Class 1, Div 2 Hazardous Locations
• DC Okay Signal
• Industrial Grade design
•
•
•
•
•
92
UL 60950
E137632
CUL/CSA-C22.2
No. 234-M90
EMC and
Low Volt.
Directive
Features (SDN4-24-100LP only)
• Power Factor Correction
• SEMI F47 Sag Immunity
•
•
UL 508 Listed
IND. CONT. EQ.
E61379
• Indefinite short-circuit, overvoltage and
overtemperature protection
• Rugged metal case and DIN connector
Narrow width on rail for space critical applications
User-friendly front panel
• Large, rugged, accessible multiple connection
screw terminations
• Easy installation
High efficiency for cooler operation and less
heat losses
High MTBF & reliability
High grade and low stress design components
No fans used or required
Five year warranty
• Meets the requirements of NEC Class 2 & UL 1310
• No derating from -10°C to 60°C, operation to 70°C
possible with a linear derating to half power from
60°C to 70°C.
Related Products
•
•
•
•
SDP™ Series
SCD Series
SCP Series
SCL Series
Applications
•
•
•
•
Industrial control
Process control
Building Automation
DeviceNetTM
Visit our website at www.solaheviduty.com or
contact Technical Services at (800) 377-4384 with any questions.
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
4
Power Supplies
SDN™ DeviceNetTM Specifications
Catalog Number
Description
SDN4-24-100LP
SDN 10-24-100P
Input
Nominal Voltage
115/230 VAC auto select (no manual required)
- AC Range
85-132/176-264 VAC
- DC Range
210-375 VDC
6
- Frequency
47 - 63 Hz
Nominal Current1
2.1 A / 1.0 A typ.
- Inrush current max.
Efficiency (Losses2)
5 A / 2 A typ.
typ. < 20 A
typ. < 30 A
> 88% typ (13.1 W)
> 88% typ (32.7 W)
Power Factor Correction
Units Fulfill EN61000-3-2
Output
Nominal Voltage
24 VDC (22.5 - 25.5 VDC adj.)
- Tolerance
24 VDC (22.5 - 28.5 VDC adj.)
< ±2% overall (combination Line, load, time and temperature related changes)
- Ripple3
< 50 mVpp
Nominal Current
3.8 A (92 W)
10 A (240 W)
- Peak Current4
4.2 A max at 23.8V
12 A
2x Nominal Current
< 2 sec.
-Current Limit
Fold Forward (Current rises, voltage drops to maintain constant power during overload up to max peak current)
Holdup Time5
> 100 ms
Parallel Operation
The SDN4 should not be used in parallel as Class 2 rating would be violated.
General
EMC
-Emissions
EN61000-6-3, -4; Class B EN55011, EN55022 Radiated and Conducted including Annex A.
-Immunity
EN61000-6-1, -2; EN61000-4-2 Level 4, EN61000-4-3 Level 3; EN61000-4-6 Level 3; EN61000-4-4 Level 4 input and Level 3 output; EN61000-4-5 Isolation Class 4,
EN61000-4-11; Transient resistance according to VDE 0160/W2 over entire load range.
Approvals
EN60950; EN50178; EN60204; UL508 Listed, cULus; UL60950, cRUus, CE (LVD 73/23 & 93/68/EEC).
EN61000-3-2, IEC60079-15 (Class 1, Zone 2, Hazardous Location, Groups A, B, C, D w/ T3A temp class up to 60°C Ambient.) SEMI F47 Sag Immunity.
SDN4 - UL60950 testing to include approval as NEC Class 2 power supply acc. to NFPA 70 art. 725-41 (a)(2).
Temperature
Storage: -25°C...+85°C Operation. -10°C...60°C full power with operation to 70°C possible with a linear derating to half power from 60°C to 70°C (Convection cooling, no
forced air required). Operation up to 50% load permissable with sideways or front side up mounting orientation. The relative humidity is < 90% RH, noncondensing;
IEC 68-2-2, 68-2-3. For operation below -10°C, contact Technical Services.
MTBF:
> 640,000 hours
- Standard
> 600,000 hours
Bellcore Issue 6 Method 1 Case 3 @ 40C
Warranty
5 years
General Protection/
Safety
Protected against continuous short-circuit, overload, open-circuit. Protection class 1 (IEC536), degree of protection IP20 (IEC 529)
Safe low voltage: SELV (acc.EN60950)
Status Indicators
Green LED and DC OK signal (N.O. Contact rated 200 mA @ <60 VDC only)
Installation
Fusing
Internally fused. External 10 A slow acting fusing for the input is recommended.
-Input
-Output
Class 2 Current Limited
Mounting
Connections
Class 1 Current Limited
Simple snap-on system for DIN Rail TS35/7.5 or TS35/15 or chassis-mounted (optional screw mounting set SDN-PMBRK2 required).
Input: IP20-rated screw terminals, connector size range: 16-10 AWG (1.5-6 mm2) for solid conductors. 16-12 AWG (0.5-4 mm2) for stranded conductors.
Output: Two connectors per output, connector size range: 16-10 AWG (1.5 - 6 mm2) for solid conductors.
Case
Fully enclosed metal housing with fine ventilation grid to keep out small parts.
-Free Space
25 mm above and below 25 mm left and right 10 mm in front
70 mm above and below 25 mm left and right 15 mm in front
HxWxD
(inches/mm)
4.88 in x 2.56 in x 4.55 in
(124 mm x 65 mm x 116 mm)
4.88 in x 3.26 in x 4.55 in
(124 mm x 83 mm x 116 mm)
1.5 lbs (620g)
2.2 lbs (1100g)
Weight (lbs/g)
1
Input current ratings are conservatively specified with low input, line conditions, worst case efficiency values and power factor spikes.
Input current at nominal input line settings will be typically half these values.
2
Losses are heat dissipation in watts at full load, nominal input line.
3
Ripple/noise is stated as typical values when measured with a 20 MHz, bandwidth scope and 50 Ohm resistor.
4
All peak current is calculated at 24 Volt levels.
5
Full load, 100 VAC Input @ Tamb = +25°C
6
Not UL listed for DC input.
Visit our website at www.solaheviduty.com or
Contact Technical Services at (800) 377-4384 with any questions.
93
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
4
Power Supplies
SDN™ Series Redundant Options
The SDN Series standard options allow for operation in
a wide variety of applications. With the addition of an
external redundancy module the SDN can also be used
for true redundant operation including 2N and
N+x configurations.
All SDN™ units include built in current sharing for parallel
and redundant operation. All models ending in P also
include a DC OK status relay contact. The external
modules SDN2.5-20RED and SDN30/40RED increase the
reliability by isolating the supplies and adding more signal
options. Paralleling for increased power does not require
the use of these modules.
EMC and
Low Volt.
Directive
Module Compatibility
Two separate modules are available to provide the
maximum flexibility in size, cost and signaling capability.
Refer to the chart below for information on which module
can be used for each SDN power supply.
Features
•
•
•
•
Power Rating – A simple yes or no indication that this
module can or cannot handle the power rating of that
power supply.
Input / Output Signals – Yes indicates that each power
supply would have an independent relay contact to
provide power supply status, and the DC bus output from
the redundant module has it’s own DC OK relay contact.
Output only indicates that only the output of the redundant
module would have a DC OK relay contact.
Smart power “DC OK Relay Contact”
True Isolation
High availability
SDN features and quality
Applications
• Process Control
• Remote Location
• Critical production
Redundancy Module Compatibility Chart
Single Phase SDN™ Series
SDN2.5-24-100P* SDN4-24-100LP*
SDN2.5-20RED
SDN30/40RED
SDN5-24-100P
SDN10-24-100P SDN20-24-100P
Power Rating
Yes
Yes
Yes
Yes
Yes
Input / Output Signals
Yes
Yes
Yes
Yes
Yes
Power Rating
Yes
Yes
Yes
Yes
Yes
Input / Output Signals
Yes
Yes
Yes
Yes
Yes
SDN5-24-480
SDN10-24-480
SDN20-24-480C
SDN30-24-480
SDN40-24-480
Three Phase SDN™ Series
SDN2.5-20RED
SDN30/40RED
Power Rating
Input / Output Signals
Yes
Yes
Yes
No
No
Output Only
Output Only
Output Only
N/A
N/A
Power Rating
Yes
Yes
Yes
Yes
Yes
Input / Output Signals
Yes
Yes
Yes
Yes
Yes
* Paralleling will violate Class 2 current limits.
94
Visit our website at www.solaheviduty.com or
contact Technical Services at (800) 377-4384 with any questions.
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
4
Power Supplies
SDN™ Redundant Series Specifications for SDN2.5-20RED and SDN30/40RED
Catalog Number
Description
SDN2.5-20RED
SDN30/40RED
Concept
By means of a separate redundancy module, you can interconnect several identical SDN power supply units in a N+1 redundant mode. These external
modules decouple the power supply outputs from each other so that, in case of failure, one power supply unit cannot overload the other units. The modules
incorporate DC OK relay contacts.
Electrical Characteristics
Voltage
24 VDC
-Nominal Value
-Max. Rated
35 V
Voltage Drop
-Vin -> Vout
Typ. 0.6 V
Current Handling Capacity
-Maximum Nominal Value
20 A
40 A
Inverse Battery Protection
Yes
Connection
-Connector size range
Via captive screw terminals
Solid: 16-10 AWG (1.5 - 6 mm2)
Stranded: 16-12 AWG (1.5 - 4 mm2)
Solid: 16-5 AWG (1.5 - 16 mm2)
Stranded: 16-8 AWG (1.5 - 10 mm2)
Note: GND must be connected to module for voltage monitor to operate properly. See Connectors and Wiring diagrams.
Relay Contacts
DC Okay Contacts
(qty) description
(1) Vout "OK" - N.O. Contact
(2) Vin "OK" - N.O. Contact
(1) Vout "OK" - N.O. & N.C. Contact
-Voltage Set Point
> 18 VDC ±5%
-Contact Rating
30 Vdc @ 2A / 250 V @ 2A
DC OK LED
Vout "OK" Green LED
> 18 VDC ±5%
-Voltage Set Point
Dimensions
(H x W x D) (in/mm)
Free Space for Ventilation
inches (mm)
Weight (lbs/g)
4.88 in x 1.97in x 4.55 in
(124 mm x 50 mm x 116 mm)
4.88 in x 2.56 in x 4.55 in
(124 mm x 65 mm x 116 mm)
Above/below: 0.39 in. (10 mm) recommended
Left/Right: 0.39 in. (10 mm) recommended
1.38 lbs (625 g)
1.43 lb (646 g)
General
Ambient Temperature
Storage: -25°C...+85°C Operation. -10°C...+60°C full power with operation to 70°C possible with a linear derating to half
power from 60°C to 70°C (Convection cooling, no forced air required). Operation up to 50% load permissable with
sideways or front side up mounting orientation. The relative humidity is < 90% RH, noncondensing; IEC 68-2-2, 68-2-3.
For operation below -10°C, contact Technical Services.
Visit our website at www.solaheviduty.com or
Contact Technical Services at (800) 377-4384 with any questions.
95
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
4
Power Supplies
Wiring Diagram for SDN2.5-20RED
Notes:
1. The Common (marked "COM - ") connection to the module is required for voltage monitoring (DC OK Contacts), and is not meant to be part of the current path from the
power supply to the load.
2. Protective earth connection only provides protective ground to the metal case of the module. This connection is isolated from the positive and common connections
96
Visit our website at www.solaheviduty.com or
contact Technical Services at (800) 377-4384 with any questions.
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
Power Supplies
4
Wiring Diagram for SDN30/40RED
Notes:
1. The Common (marked "COM - ") connection to the module is required for voltage monitoring (DC OK Contacts), and is not meant to be part of the current path from the
power supply to the load.
2. Protective earth connection only provides protective ground to the metal case of the module. This connection is isolated from the positive and common connections
Visit our website at www.solaheviduty.com or
Contact Technical Services at (800) 377-4384 with any questions.
97
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
4
Power Supplies
SDP™ Low Power DIN Rail Series
The compact, lightweight DIN Rail power supplies come in
output voltages from 5 to 48 VDC and power ratings of up
to 100 Watts. These extra small, efficient units are
designed specifically for the industrial environment. Each
unit is rated from -10ºC to 70ºC, with no derating
necessary until above 60ºC.
Many extra “industrial” features are standard for the
SDP™ PowerBoostTM overload circuitry can start up
industrial loads (i.e. motors, relays, solenoids and DC-DC
converters), that can cause ordinary power supplies to
foldback or shutdown. Each unit contains a DC indicator
and front panel adjustment potentiometer. With the Sola
SDP™ series, you can count on a high grade design.
UL 508 Listed
IND. CONT. EQ.
E6I379
Features
•
•
•
•
•
•
•
•
UL 60950
E137632
CUL/CSA-C22.2
No. 234-M90
EMC and
Low Volt.
Directive
Related Products
Ultra slim 15W footprint
No tools required for mounting
Adjustable output
PowerBoostTM industrial overload design
Overvoltage, short circuit protection
NEC Class 2 current limited
Continuous short circuit protection
Low output noise
• SDN™ Series
• SCP Series
• SCL Series
Applications
•
•
•
•
•
• Screw terminal connections
• Three year warranty
Industrial control
Process control
Machine control
Building Automation
Instrumentation
Selection Table
Catalog Number
DC Output Voltage
Output Current
SDP5-5-100T
5-6V
5A
SDP2-12-100T
10 - 12 V
3 - 2.5 A
SDP3-15-100T
12 - 15 V
4.2 - 3.4 A
SDP1-48-100T
48 - 56 V
1A
SDP06-24-100T
0.6 A
SDP1-24-100T
1.3 A
SDP2-24-100T
24-28 VDC
Ripple / Noise
2.95 in x 1.77 in x 3.58 in
(75 mm x 45 mm x 91 mm)
<50 mVpp
2.1 A
SDP4-24-100LT
3.8 A
SDP4-24-100RT*
4.2 A
Size (H x W x D)
2.95 in x 0.9 in x 3.8 in
(75mm x 22.8 mm x 96.7 mm)
2.95 in x 1.77 in x 3.58 in
(75 mm x 45 mm x 91 mm)
2.95 in x 2.85 in x 3.8 in
(75 mm x 72.5 mm x 96.7 mm)
* NEC Class 1
98
Visit our website at www.solaheviduty.com or
contact Technical Services at (800) 377-4384 with any questions.
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
4
Power Supplies
SDP™ Series Specifications (24 V models)
Description
Catalog Number
SDP06-24-100T
SDP1-24-100T
SDP2-24-100T
SDP4-24-100RT
SDP4-24-100LT
Input
Input Voltage
Input Frequency
Input Current
47-63 Hz
0.4 A / 0.25 A
0.7 A / 0.4 A
External Fusing
1.1 A / 0.7 A
Losses
2.2 A / 1.2 A
1.8 A / 1.0 A
Not required. Unit provides internal fuse (T3A, not accessible)
Hold-Up Time
Efficiency
85-132 / 176-264 VAC
210-375 VDC
85-264 VAC, 90-375 VDC
3
> 25 ms
> 80% typ.
> 83% typ.
> 86% typ.
> 88% typ.
< 3.75 W typ.
< 6.1 W typ.
< 8.1 W typ.
< 12 W typ.
Output
Output Voltage
24 V (22.5 - 28.5 VDC Adj.)
Voltage Regulation
Static 0.5% Vout, dynamic + 2% Vout overall
Ripple/Noise1
< 50 mVpp
Overvoltage Protection (OVP)
> 30 VDC, but < 33 VDC, auto recovery
Output Noise Suppression
Rated Continuous Loading
Radiated EMI values below EN61000-6-2
0.63 A @ 24 VAC /
0.54 A @ 28 VAC
Overload Behavior
1.3 A @ 24 VDC /
1.1 A @ 28 VDC
2.1 A @ 24 VDC /
1.8 A @ 28 VDC
4.2 A @ 24.5 VDC /
3.6 A @ 28 VDC
3.8 A @ 24.5 VDC
Continuous operation at overload/short-circuit: up to 1.5 x Nominal Current Continuous
Protection
Unit is continuously protected against short-circuit, overload and open-circuit.
Power Back Immunity
35 V
Installation
Status Indicators
Green LED on, when Vout “OK”.
Case & Mounting
Molded plastic housing using UL 94 approved flameproof material rating 94V-2. Simple snap-on to DIN TS35/7.5 or TS35/15 rail system.
Dimensions
(H x W x D) (in/mm)
Weight
Mounting Orientation
2.95 in x 0.9 in x 3.8 in
(75 mm x 22.8 mm x 96.7 mm)
2.95 in x 1.77 in x 3.58 in
(75 mm x 45 mm x 91 mm)
2.95 in x 2.85 in x 3.8 in
(75 mm x 72.5 mm x 96.7 mm)
0.35 lbs (150 g)
0.5 lbs (240 g)
0.7 lbs (320 g)
Standard: Vertical; Optional: Horizontal or On Top (Contact Technical Services).
Ventilation/Cooling
•Free space for cooling
Normal convection, no fan required; Above/below: 25 mm recommended.
Connection
•Connector size range
Input: screw terminals, connector size range: 20-12AWG (1.5 - 6 mm2) for solid or stranded conductors.
General
Temperature
MTBF
Humidity
Electromagnetic Emissions (EME)
Electromagnetic Immunity (EMI)
Storage: -25°C...+85°C Operation. -10°-60°C full power with linear derating to half power from 60°C to 70°C.
(Convection cooling, no forced air required).
> 500,000 hours according to Telcordia/Bellcore Document SR-332, Issue 1.
Up to 90% RH, noncondensing; IEC 68-2-2, 68-2-3
EN61000-6-3 (Includes EN61000-6-4) Class B (EN 55022) incl. Annex A
EN61000-6-2 (Includes EN61000-6-1) (EN55024) Criterion A: no derogation of performance
Safe Low Voltage
Protection Class/Voltage
SELV (acc. EN60950)
IP20 (IEC529), Protection Class 1 (IEC536)
Warranty
3 years
Safety
CB Scheme, EN60950, EN50178, EN60204, EN60079-15 (Class 1, Zone 2 Hazardous Locations, Temp Class T3), UL508 Listed, cULus, UL 60950, cURus, CE (LVD 73/23 & 93/68/
EEC). (EMC 89/336 & 93/68/EEC). EN61000-3-2, NEC Class 2 power supply acc. To NFPA 70 art. 725-41 (a)(2).2
Notes:
1
Ripple/noise is stated as typical values when measured with a 20 MHz, bandwidth scope and 50 Ohm resistor.
2
For models less than 100W.
3
Not UL listed for DC input.
Visit our website at www.solaheviduty.com or
Contact Technical Services at (800) 377-4384 with any questions.
99
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
4
Power Supplies
SDP™ Series Specifications (Other Voltages)
Description
Catalog Number
SDP5-5-100T
SDP2-12-100T
SDP3-15-100T
SDP1-48-100T
Input
Input Voltage3
85-264 VAC, 90-375 VDC
Input Frequency
47-63 Hz
0.6 A @ 102 VAC;
0.33 A @196 VAC
Input Current
External Fusing
1.0 A @ 102 VAC;
0.6 A @ 196 VAC
<1.0 A @ 100 VAC;
<0.6 A @ 196 VAC
Not required. Unit provides internal fuse (T3A, not accessible)
Hold-Up Time
> 25 ms
Efficiency
> 80% typ
Losses
7.5 W typ.
> 86% typ.
90% typ.
8.1 W typ.
Output
Output Voltage
5 - 5.5 VDC (5 - 6 min adj.)
Voltage Regulation
12 VDC (9.9 - 12.1 min adj. )
Ripple/Noise1
Overvoltage Protection (OVP)
> 6.7 VDC
> 18 VDC
> 20 VDC
> 60 VDC
Radiated EMI values below EN61000-6-2
lout = 5 A @ Vout = 5.1V
Overload Behavior
3 A @ 10 VDC
2.5 A @12 VDC
4.2 A @ 12 VDC
3.4 A @ 15 VDC
Up to 1.05 A @ 48 V
0.9 A @ 56 V
Continuous operation at overload/short-circuit: up to 1.5 x Nominal Current Continuous.
Protection
Power Back Immunity
48 VDC (48 - 56 min adj.)
< 50 mVpp
Output Noise Suppression
Rated Continuous Loading
15 VDC (11.9 - 15.1 min adj.)
< 2% Dynamic; < 0.5% Static
Unit is continuously protected against short-circuit, overload and open-circuit.
10 V
22 V
80 V
Installation
Status Indicators
Green LED on, when Vout “OK”.
Case & Mounting
Molded platic housing using UL 94 approved flameproof material rating 94V-2. Simple snap-on to DIN TS35/7.5 or TS35/15 rail system.
Dimensions
Dimensions
(H x W x D) (in/mm)
2.95 in x 1.77 in. x 3.58 in
(75 mm x 45 mm x 91 mm)
Weight
Mounting Orientation
0.5 lbs (240 g)
Standard: Vertical; Optional: Horizontal or On Top (Contact Technical Services).
Ventilation/Cooling
•Free space for cooling
Normal convection, no fan required; Above/below: 25 mm recommended.
Connection
•Connector size range
Input: screw terminals, connector size range: 20-12 AWG (1.5 - 6 mm2) for solid or stranded conductors.
General
Temperature
MTBF
Humidity
Storage: -25°C...+85°C Operation. -10°-60°C full power with linear derating to half power from 60°C to 70°C.
(Convection cooling, no forced air required).
> 500,000 hours according to Telcordia/Bellcore Document SR-332, Issue 1.
Up to 90% RH, noncondensing; IEC 68-2-2, 68-2-3
Electromagnetic Emissions
(EME)
EN61000-6-3 (includes EN61000-6-4) Class B (EN55022) incl. Annex A
Electromagnetic Immunity
(EMI)
EN61000-6-2 (Includes EN61000-6-1) (EN55024) Criterion A: no degradation of performance
Safe Low Voltage
Protection Class/Voltage
SELV (acc. EN60950)
IP20 (IEC529), Protection Class 1 (IEC536)
Warranty
3 years
Safety
CB Scheme, EN60950, EN50178, EN60204, EN60079-15 (Class 1, Zone 2 Hazardous Locations, Temp Class T3), UL508 Listed, cULus, UL 60950, cURus, CE (LVD 73/23
& 93/68/EEC), (EMC 89/336 & 93/68/EEC). EN61000-3-2, NEC Class 2 power supply acc. To NFPA 70 art. 725-41 (a)(2).
Notes:
1
Ripple/noise is stated as typical values when measured with a 20 MHz, bandwidth scope and 50 Ohm resistor.
2
Not to exceed 30 watts total.
3
Not UL listed for DC input.
100
Visit our website at www.solaheviduty.com or
contact Technical Services at (800) 377-4384 with any questions.
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
4
Power Supplies
SCL Series, 4 and 10 Watt CE Linears
Selection Table
Catalog
Number
Output Voltages
V1
Description
VDC
V2
A
V3
VDC
A
VDC
A
4 Watt; Linear DC Power Supply; DIN Rail Mount
SCL4D12-DN
Dual O/P ±12 V
12
0.13
-12
0.13
-
-
SCL4D15-DN
Dual O/P ±15 V
15
0.1
-15
0.1
-
-
10 Watt; Linear DC Power Supply; DIN Rail Mount
SCL10D12-DN
Dual O/P ±12 V
12
0.35
-12
0.35
-
SCL10D15-DN
Dual O/P ±15 V
15
0.3
-15
0.3
-
-
SCL10T512-DN
Triple O/P, 5 V ±12 V
5
0.2
12
0.3
-12
0.3
SCL10T515-DN
Triple O/P, 5 V ±15 V
5
0.2
15
0.25
-15
0.25
Note: Dual output units can be series connected for 24V or 30V applications.
UL 508 Listed
IND. CONT. EQ.
E201985
UL 60950
E137632
CUL/CSA-C22.2 EMC and
No. 234-M90 Low Volt.
Directive
Standards
The 4 and 10 Watt encapsulated linears are available in
dual and triple outputs for applications with sensitive
electronics and analog circuitry. The rugged enclosed
encapsulated package, with screw terminals and DIN Rail
clips, make for easy installation and maintenance.
These low-noise modules are capable of being DIN Rail
or Chassis mounted.
Features
•
•
•
•
•
Quiet, low noise DC Linear technology
DIN Rail or Chassis mount for easy installation
Rugged encapsulated design
Global specifications including CE and UL 508
Two year warranty
Packaging and Mounting Specifications
•
•
•
•
•
•
•
•
CE Certified
UL 508 Listed
EN55011/13, 55022/B
ENV 50140, 10 V/m
EN61000-4-2, Level 4
EN61000-4-4, Level 4
EN61000-4-5, Level 2
EN60950
Dimensions (H x W x D)
• 4 watt:
4.31 x 2.0 x 0.90 inches
110 x 51 x 23 mm
• 10 watt: 4.71 x 2.55 x 1.29 inches
120 x 65 x 33 mm
• Simple snap-on for DIN Rail TS35/7.5 or TS35/15
• M3 screw clamp terminations
• Chassis mounting possible on -DN Low-Profile
versions by removing DIN clips
(simply unscrew at the back of the unit).
Visit our website at www.solaheviduty.com or
Contact Technical Services at (800) 377-4384 with any questions.
101
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
4
Power Supplies
SCL Series
Specifications
Parameter
Dimensions – mm (inches)
Condition
Value
SCL 4 Watt Linear
Input
D =
4.5(.18)
115/230 ±10% VAC
Field Selectable
Vin: AC Input Voltage
fin: Input Frequency
47-63 Hz
1
10 Watt: 0.2 A/0.1 A max
4 Watt: 0.1 A/0.05 A max
Iin: Input Current 115/230 V
Efficiency
Vout: Trimming
95(3.73)
110(4.31)
Side View
Output
Front View
Vin=min, Iout=max, 25°C
<5 mVpp
100...50%, 25°C
<0.05%
10...90...10%, 25°C
100 ms
TA = -25...+65°C
0.01%/K typ.
th: Holdup Time
min. 20 ms
Pover: Overload/
Short Circuit
Continuous
General
Conducted Emissions
EN 55 011, Level B
ESD
HF
Burst
V = 230 VAC, 50 Hz
>100 MOhm
2 cm side, middle case
SCL-4
1
3
5
6
7
8
Dual
12 / 15V
COM 12 / 15V
-12 / -15V
IN
IN
IN
SCL 10 Watt Linear
D =
4.2(.16)
<0.05 mA
1
2
3
4
5
10 W: -20...+70°C
4 W: -25...+70°C
TA > 50°C
3%/K
TS: Storage Temperature
-40...+85°C
Cooling
Convection
10 Watt: 1.2 lbs (550 g)
4 Watt: 0.44 lbs (200 g)
Weight (lbs/g)
Case Material/Potting
Front View
106(4.16)
TA: Operating Temperature
Derating
Pin-Out
120(4.71)
Llea: Leakage Current
3.0kVAC, EN 60 950
51(2.0)
115(4.51)
Risol: Isolation Resistance
TA = 25°C
39(1.53)
6
(.24)
4.5
Visol p/s: Isolation Voltage
(input/output)
EN 61 000-4-2, Level 4
ENV 50 140 (10 V/m)
EN 61 000-4-4, Level 4
23(.90)
(.18)
ε: Temperature Coefficient
115V 230V
UL94-VO
CSA Power Supply Class
57.5(2.26)
tR: Load Regulation
Timing
0
Side View
Regulation Accuracy
7.5
<5 mVpp
ΔVHF: Noise
(.29)
Vin=min, Iout=max, 25°C
55(2.16)
Fixed, preset
ΔVNF: Ripple
SELV
5
Typ. 50%
10 Watt Only:
VDE 0871/B
Filtering
Inducted Noise
3
Level
Protection Class
Class 2
0 115V
33(1.29)
230V
53(2.08)
65(2.55)
6
(.24)
Pin-Out
102
SCL 10
1
Dual
-12/15V
Triple
-12/15V
2
3
4
GND 12/15V
5V
GND 12/15V
COM 5V
5
6
7
8
12/15V
IN
IN
IN
12/15V
IN
IN
IN
Visit our website at www.solaheviduty.com or
contact Technical Services at (800) 377-4384 with any questions.
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
4
Power Supplies
SCP Series, 30 Watt; Single, Dual and Triple
Selection Table
Output Voltages
Low Profile
Catalog
Number
Description
V1
V2
V3
VDC
A
VDC
A
VDC
A
Min
Load
V1
A
Efficiency
%
30 Watts; Switching DC Power Supply
UL 60950
E137632
CUL/CSA-C22.2 EMC and
No. 234-M90 Low Volt.
Directive
SCP30S3.3-DN
3.3 V
3.3
6.0
-
-
-
-
0
≥ 62
SCP30S5-DN
5V
5
6.0
-
-
-
-
0
≥ 70
SCP30S12-DN
12 V
12
2.5
-
-
-
-
0
≥ 75
SCP30S15-DN
15 V
15
2.0
-
-
-
-
0
≥ 75
SCP30S24-DN
24 V
24
1.3
-
-
-
-
0
≥ 77
SCP30S48-DN
48 V
48
0.6
-
-
-
-
0
≥ 77
SCP30D12-DN
Dual O/P +/- 12 V
12
1.2
-12
1.2
-
-
0.12
≥ 68
SCP30D15-DN
Dual O/P +/- 15 V
15
1.0
-15
1.0
-
-
0.15
≥ 68
SCP30D512-DN
Dual O/P 5 V & 12 V
5
3.0
12
1.2
-
-
0.3
≥ 68
SCP30D524-DN
Dual O/P 5 V & 24 V
5
3.0
24
0.6
-
-
0.3
≥ 68
SCP30T512-DN
Triple O/P 5/12/12 V
5
3.0
-12
0.6
12
0.6
0.3
≥ 68
SCP30T515-DN
Triple O/P 5/15/15 V
5
3.0
-15
0.5
15
0.5
0.3
≥ 68
Please order using the following model number suffixes:
These switchers are compact, rugged power supplies
designed to power many of your industrial control and
instrumentation devices and equipment, with high reliability
and tight regulation through the most difficult factory-floor
conditions around the globe. “User friendly” applies to
these unique power supplies that feature easy-to-install
DIN Rail and chassis mounting. Terminations are also easy
to access (AC and DC terminations are well separated)
and simple to wire. Safety is another aspect where the
SCP distinguishes itself. The encapsulated design meets
IP20 specifications, and the wide range of voltages will
reliably support almost any low-power device in your
cabinet or system for years to come.
Low Profile – DIN Rail or Chassis Mount (ie: SCP30S3.3-DN).
B-DN: Slim Line – DIN Rail Mount Availability Only (ie: SCP30S3.3B-DN).
Note: Slim line version not available on SCP30D512-DN
Packaging and Mounting Specifications
• Simple snap-on for DIN Rail TS35/7.5 or TS35/15
• M3 screw clamp terminations
• Chassis mounting possible on -DN Low-Profile
versions by removing DIN clips (simply unscrew
at the back of the unit).
Options and Accessories
Features
•
•
•
•
•
•
-DN:
International approvals for global use
DIN Rail or Chassis Mount
Rugged, encapsulated design to resist environment
IP20 protection
Many output voltages, 3.3-48 Volts; single, dual, triple
5-year warranty
• SCP-MDC – Pair of metal DIN clips
• SCP-PDC – 1 plastic DIN clip with lever for
removal from rail
Standards
• UL60950, E137632
• EN60950
• CE and IP20
Visit our website at www.solaheviduty.com or
Contact Technical Services at (800) 377-4384 with any questions.
103
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
4
Power Supplies
SCP Series
Specifications
Parameter
Dimensions – mm (inches)
Condition
Value
Low Profile DIN Rail (-DN) or Chassis Mount*
Input
Vin: AC Input Voltage
85…264 VAC
Vin: DC Input Voltage
100…375 VDC
fin: Input Frequency
50/60 HZ
Filtering EMI/RFI
EN 55011/B, 55022/B
fsw: Switching Frequency
Typ. 100 kHz
Input Fusing Required
Use 2.0 A Slow Fuse
D = 4.2(.16)
5 4 3
2 1
≤2%, Vout
Line Regulation
Vin=min/max 25°C
Iout = max, 25°C
≤+0.5%, Vout
Load Regulation
Iout = 10…90…10%, 25°C
Vin = 230VAC, 25°C
≤+0.5%, Vout
IMAX: Overcurrent Protection
Front View
105…130% Inom
10...90...10%, 25°C
<4 ms
Temperature Coefficient
TA = -25...+65°C
0.01%/K
Overload/Short Circuit
Continuous
Derating Single/Dual/Triple
TA >50°C
6
33(.1.29)
2/3/5%/K max
6
(.24)
Vin =230 VAC
>50 ms
TA: Operating Temperature
-25…+65°C
TA = 25°C
-45...+85°C
Case Temperature Rise
at Full Load
Slim Line DIN Rail Mount only (B-DN)
45 K max
800,000 hrs
Transient Protection
EN61000-4-2, 3, 4, 5
Cooling
Convection
Weight (lbs/g)
0.75 lbs (340g)
0.84 lbs (380g)
Case Material/Potting
UL94-VO
CSA Power Supply Class
Level 3
Protection
IP20
Visual Indicators
Green LED indicates
DC OK for B-DN Slim
Line versions only
1 2 3 4 5
Front View
Side View
113 (4.43)
acc. MIL-HDBK-217F
102 (4.0)
MTBF at 25°C (input/output)
* Unscrew DIN connector for chassis mounting.
90 (3.53)
TS: Storage Temperature
53(2.08)
65(2.55)
General
th: Holdup Time
7
4.5
tR: Load Regulation Timing
120(4.71)
Vin=min, Iout=max, 25°C
106(4.16)
≤1%, Vout
ΔVNF: Noise
115(4.51)
V1≤ ±1%, V2/3 ≤ ±3%
Vin=min, Iout=max, 25°C
(.18)
Vin = 230V, Iout = max, 25°C
ΔVNF: Ripple
57.5(2.26)
ΔVout: Output Voltage Accuracy
Side View
Output
Dimensions (H x W x D)
• Low Profile “-DN”
4.72 x 2.55 x 1.29 inches
120 x 65 x 33 mm
(Takes up 2.55 inches or 65 mm on DIN Rail)
• Slim Line “B-DN”
4.72 x 1.29 x 2.68 inches
120 x 33 x 68 mm
(Takes up 1.29 inches or 33 mm on DIN Rail)
6 7
68(2.67)
Pin-Out
SCP 30
1
2
3
Single
Dual sym
Dual asym
Triple
104
35(1.37)
-V2
4
5
6
7
RETURN
+V1
IN
IN
-V2
COM
+V1
IN
IN
COM (V1)
+V1
COM V3
+V3
IN
IN
COM (V1)
COM (V2/3)
+V1
+V3
IN
IN
Visit our website at www.solaheviduty.com or
contact Technical Services at (800) 377-4384 with any questions.
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
4
Power Supplies
SCD Series, Encapsulated, Industrial DC to DC Converter
These compact, rugged DC to DC converters are
power supplies designed to power industrial control
instrumentation devices and equipment where AC power
is not convenient or accessible. With high reliability and
wide input range, these units can operate through the most
difficult factory-floor conditions around the globe. “User
friendly” applies to these unique power supplies that
feature easy-to-install DIN Rail and chassis mounting.
Terminations are also easy to access and simple to wire.
Encapsulated design meets IP20 specifications for use
in harsh environments.
Features
•
•
•
•
•
•
•
•
DIN Rail or Chassis mount by removing DIN clips
Rugged, encapsulated design to resist environment
IP20 protection
Wide 20 to 72 VDC input range
5-year warranty
Simple snap-on for DIN Rail TS35/7.5 or TS35/15
M3 screw clamp terminations
Galvanic isolation
Options and Accessories
• SCP-MDC – Pair of metal DIN clips
• SCP-PDC – 1 plastic DIN clip with lever for
removal from rail
Standards
• UL60950, C22.2 (CRU) & UL508
• CE and IP20
UL 508 Listed
IND. CONT. EQ.
UL 60950
E137632
CUL/CSA-C22.2 EMC and
No. 234-M90 Low Volt.
Directive
Applications
These easy-to-mount and install units can be used to
regulate voltage for sensitive electronic equipment run
from battery power. A good example would be a 24 VDC
battery system. The battery voltage can be 30 volts, sometimes higher during charging, and dip below 22 volts under
heavy load. The SCD can be used to stabilize the voltage
for those devices not designed to handle wider voltage
swings.
They are also a convenient and inexpensive alternative to
running AC power through a large industrial machine. The
SCD can use 24 VDC commonly available on many parts
of the machine to create other voltages needed to run
sensors, transducers and other devices that the machine
requires to work properly.
• Industrial
- Encoders, special sensors, communications
and instrumentation
• Telecommunications systems
• Remote Site/Harsh Environment
Visit our website at www.solaheviduty.com or
Contact Technical Services at (800) 377-4384 with any questions.
105
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
4
Power Supplies
SCD Series, Encapsulated, Industrial DC to DC Converter
Specifications
Selection Table
Output Voltages
Low Profile
Catalog Number
Description
V1
VDC
V2
A
VDC
A
Min
Load
V1 A
30 Watts; Switching DC Power Supply
SCD30S5-DN
5V
5
5
-
-
0
SCD30S12-DN
12 V
12
2.5
-
-
0
SCD30S15-DN
15 V
15
2
-
-
0
SCD30S24-DN
24 V
24
1.3
-
-
0
SCD30S48-DN
48 V
48
0.6
-
-
0
SCD30D15-DN
Dual O/P+15 V
15
0.8
-15
0.8
0.15
Dimensions
Parameter
Condition
Value
Input
Input Voltage
20…72 VDC
Filtering EMI/RFI
EN 55011/B,
55022/B
fsw: Switching Frequency
Typ. 100 kHz
Output
ΔVout: Output Voltage
Accuracy
Vin = 48V,
Iout = max, 25°C
V1≤+1%, V2 ≤+4%
ΔVNF: Ripple
Vin= min,
Iout=max, 25°C
≤1%, Vout
ΔVNF: Noise
Vin= min,
Iout= max, 25°C
≤2%, Vout
Line Regulation
Vin= min/max 25°C
Iout = max, 25°C
≤+0.5%,
0.5%, Vout
Load Regulation
Iout = 10…90…10%,
25°C Vin = 48 V, 25°C
≤+0.5%,
0.5%, Vout
IMAX: Overcurrent Protection
105…130% Inom
tR: Load Regulation Timing
10...90...10%, 25°C
<4 ms
Temperature Coefficient
TA = -25...+65°C
0.01%/K
Overload/Short Circuit
Continuous
Derating
TA >50°C
th: Holdup Time
Vin = 48 V
5%/K max
General
TA: Operating Temperature
TS: Storage Temperature
-25…+65°C
TA = 25°C
Case Temperature Rise at
Full Load
MTBF at 25°C (input/output)
* Unscrew DIN connector for chassis mounting.
>10 ms
-45...+85°C
45 K max
acc. MIL-HDBK-217F
800,000 hrs
Transient Protection
EN61000-4-2, 3,
4, 5
Cooling
Convection
Weight (lbs/g)
0.86 lbs (390g)
Case Material/Potting
UL94-VO
CSA Power Supply Class
Level 3
Protection
IP20
Note: No input protection against reverse voltage.
Pin-Out
SCD 30
1
Single
+V1
-V1
Dual
V1
COM
106
2
3
V2
6
7
+IN
-IN
+IN
-IN
Visit our website at www.solaheviduty.com or
contact Technical Services at (800) 377-4384 with any questions.
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
4
Power Supplies
SFL Series, 75–600 Watt
The SFL series is a DIN Rail switching power supply
series that complements the Sola SDN™ products with
more input voltage, output voltage and power levels to
give an even broader range of industrial DC power
solutions. These products are available in 12, 24 and 48
VDC output and 115/230 VAC Input. They feature
pluggable screw connectors* (mating connectors are
included in each box sold) for easy installation and
service. The products feature a DIN Rail connection,
front panel DC OK indicators, and easily accessible AC
and DC connections.
For parallel operation with power sharing, a redundant
version is available for the 300 W (24 V/12 A) and 600 W
(24 V/24 A) models.
Features
• DIN Rail Mount regulated switch mode
power supplies
• 12 V, 24 V, and 48 V outputs available from 1.5-24 A
• Easy-to-wire pluggable* and screw terminal
connectors
• Output voltage adjustable
• Selectable input: 115/230 VAC
• UL1604 Listed for Class 1, Division 2 hazardous
locations (except -RED versions)
• UL 508 Listed (except -RED versions). No derating
necessary.
Listed
Ind. Cont.
EQ. Haz. Loc.
E196762
Listed
Ind. Cont.
EQ. E61379
UL 60950
E137632
CUL/CSA-C22.2 EMC and
No. 234-M90 Low Volt.
Directive
• Fully Integrated Redundant models available:
- RED (For SFL24-24-100 and SFL12-24-100 only)
Designed for N + 1 redundant power supply systems,
these units provide active current sharing and allow
up to 5 power supplies to be paralleled. Decoupling
diodes and an alarm output to signal a unit failure
are included in this option. Multiple units are required
for redundancy.
• Models with optional battery back-up available:
• Two year warranty
- UDS (For SFL24-24-100 and SFL12-24-100 only)
Contact Technical Services for details.
* Except 600 watt models.
Selection Table
Input Voltage
Selectable
Output Power
Maximum
Output Voltage
Nominal
Output Current
Maximum
SFL6-12-100
SFL1.5-48-100
115/230 VAC
75 Watt
12 VDC
48 VDC
6A
1.5 A
SFL3-48-100
115/230 VAC
150 Watt
48 VDC
3A
SFL12-24-100
SFL6-48-100
115/230 VAC
300 Watt
24 VDC
48 VDC
12 A
6A
SFL24-24-100
SFL12-48-100
115/230 VAC
600 Watt
24 VDC
48 VDC
24 A
12 A
115/230 VAC
300 Watt
600 Watt
24 VDC
12 A
24 A
Catalog Number
Redundant Models
SFL12-24-100RED
SFL24-24-100RED
Visit our website at www.solaheviduty.com or
Contact Technical Services at (800) 377-4384 with any questions.
107
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
4
Power Supplies
SFL Specifications
Parameter
Value
Parameter
Input
Input voltages nominal (user selectable)
93-132 VAC / 187-264 VAC
fin: Input Frequency
47-63 Hz
Input current at full load (typical)
- 75 W (12 V/6 A, 24 V/3 A, 48 V/1.5 A)
- 150 W (24 V/6 A, 48 V/3 A)
- 300 W (24 V/12 A, 48 V/6 A)
- 600 W (24 V/24 A, 48 V/12 A)
115 VAC
1.7A
3.0A
5.4A
10.5A
230 VAC
0.9 A
1.7 A
3.3 A
6.4 A
Inrush current (max.)
- 75 W
- 150 W
- 300 W
- 600 W
115 VAC
16.5 A
35.0 A
35.0 A
70.0 A
230 VAC
33.0 A
70.0 A
70.0 A
80.0 A
Internal fuse (slow blow) not accessible
- 75 W / 150 W
- 300 W
- 600 W
4.0 A
6.3 A
12.0 A
Output Regulation
- Line voltage variation
- Load variation 10–90%
75W, 150W models
300W, 600W models
Ripple and noise (20 MHz bandwidth)
Electronic short circuit protection /
current limitation
Parallel Operation
- SFL12-24-100RED
- SFL24-24-100RED
IMAX: Overvoltage Protection,
trigger point at
th: Holdup Time
TA: Operating Temperature Range
Derating above 50°C
TS: Storage Temperature
-25°C...+70°C 2%/°C
-25°C...+85°C
Humidity (non condensing)
95% rel H max.
Switching Frequency
- 75 W
- 150 W/300 W/600 W
100 kHz typical
67 kHz typical
Efficiency
Operation Indication
Isolation Voltage
- Input/output
- Input/case
- Output/case
>85%
LED, DC OK
3,000 VAC (1 minute)
2,000 VAC (1 minute)
500 VAC (1 minute)
Safety Class (IEC536)
Class 1
12 – 14 VDC
24 – 28 VDC
48 – 52 VDC
Safety Standards Met
IEC950,EN60950,CE marked for
LVD, UL60950 recognized
and UL 508.
±0.2% max.
Electromagnetic Susceptibility
- Electrostatic discharge ESD.
- RF field susceptibility.
- Electrical fast transients/
bursts on mainsline.
- Immunity to conducted radio
frequency disturbances above 9 kHz.
- Mains frequency field
Output
Voltage Adjustment Range
- 12 V models
- 24 V models
- 48 V models
Value
General
±1.0% max.
±0.5% max.
< 50 mVpp
110 % typ. (constant current)
Up to 5 units
140% typical out nominal
min. 20 mS
Conducted EMI according to:
EN55022 Class B, EN55011
Class B, FCC-B
EN61000-4-2
EN61000-4-3
EN61000-4-4
4 kV/8 kV
10 V/m
2 kV
EN61000-4-6
10 V
EN61000-4-8
30 A/m
Case protection according to IEC529
IP20
Case material
Steel
Mounting
Snap-on 35 mm DIN Rail as per
EN50022 or Chassis mounting
option available
Mounting Brackets
For easy conversion to panel or chassis mounting.
108
Catalog Number
Output Power Maximum
SFL75-PMBRK
SFL150-PMBRK
SFL300-PMBRK
SFL600-PMBRK
75 Watt
150 Watt
300 Watt
600 Watt
Visit our website at www.solaheviduty.com or
contact Technical Services at (800) 377-4384 with any questions.
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
4
Power Supplies
SFL Series Dimensions (inches/mm)
SFL 150 Watt (SFL 3-48-100)
SFL 75 Watt (12 V/6 A, 48 V/1.5 A)
SOLA
SFL 6-12-100
Clip for
35 mm DIN-rail
LED
4.51 (114.6)
SOLA
LED
SFL3-48-100
4.51 (114.6)
2.25
(57.3)
2.25 (57.3)
1.77
(45)
2.23
(56.7)
.27 (7)
Weight: 1.06 lbs/480 g approx.
S O LA
SFL 12-24-100
SFL 600 Watt (SFL 12-48-100, SFL 24-24-100[RED])
S O LA
3.25
(82.6)
1.06
(27.1)
LED
.60 (15.3)
2.24
(57.0)
SFL 24-24-100
3.26
(83)
8.14 (207)
5.11 (130)
Vout
adi
NP
LED
2.25
(57.3)
1.51
(38.5)
.27 (7)
Weight: 1.6 lbs/800 g approx.
SFL 300 Watt (SFL12-24-100 [RED], SFL6-48-100)
4.51 (114.6)
3.14 (80)
50V
2.23 (56.7)
2.23
(56.7)
6.18 (157)
1.51
(38.5)
50V
2.23 (56.7)
3.54
(90)
6.97 (177.2)
.13
(3.4)
6.97 (177.2)
.27 (7)
50V
9.56 (243)
3.26 (83)
1.83
(46.5)
5.90 (150)
.27 (7)
3.25 (82.8)
Weight: 3.09 lbs/1400 g approx.
Weight: 4 lbs/2000 g approx.
Visit our website at www.solaheviduty.com or
Contact Technical Services at (800) 377-4384 with any questions.
109
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
4
Power Supplies
Silver Line Series – Single & Multi-Output Linears
Specifications
Parameter
Condition
Limit
Input
100/120/220/230/240
VAC Selectable
Input Voltage
Input Frequency
47-63 Hz
Output
Line Regulation
for 10% change
Load Regulation
for 50% change
The Silver Line series follows the industry accepted
footprint for open frame, linear power supplies. Sola
improves on this design by offering standard screw
terminal connections and optional covers for safety
considerations.
Features
•
•
•
•
•
•
•
•
•
•
Easy-to-install screw terminal connections
Cover options
Industry standard footprint
Universal input and approvals (115/230 VAC)
Low noise, extremely quiet DC output. For noise
sensitive or analog circuitry.
Fast transient response. Ideal for test applications.
Built-in OVP on 5 V models and optional on
12, 15 and 24 V models
Automatic resetting overload protection
Short circuit protected
Two year warranty
Applications
•
•
•
•
•
•
•
•
110
Industrial control circuits and components
Instrumentation
Drives
CNC machinery
Equipment for food industry
Microprocessor circuits
Analog circuits
Noise sensitive circuitry and sensors
LVD
DC Output
Adjustment Range
±5% Minimum
All 5-Volt outputs
include build-in OVP
as standard (setting is
6.2 V ±0.4 V) OVP is
optionally available on
other types
Overvoltage
Protection
Transient
Response Time
at 50% Load Changes
Overload
Protection
Remote Sensing
0.05%
3.0 mV maximum
Peak-to-Peak
Ripple
UL 60950
E137632
0.05%
50 msec.
Automatic current limit
foldback
Available to
compensate for output
voltage drop on
selected models.
0.5 VDC
General
Operating
Temperature Range
Derate to 40% at
+70°C
0 to +50°C
Storage
Temperature Range
-25°C to +85°C
Temperature
Coefficient (Typical)
0.01% 0°C
Stability
After warm-up
±.5%
Vibration
Method 514
Per MIL-STD-810C
Shock
Method 516
Per MIL-STD-810C
Linear power supplies
have inherently low
conducted and radiate
noise levels
For most system
applications they will
meet requirements of
FCC Class B and VDE
0871 for class B
EMI/RFI
Cover Option
Cooling
Derate power by an additional 15%
Forced air. 20 CFM required for full rating
Derate 30% without cooling
Specifications are typical. Load Regulation on outputs without Remote
Sense, .1% typical.
Visit our website at www.solaheviduty.com or
contact Technical Services at (800) 377-4384 with any questions.
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
4
Power Supplies
SL Series Selection Table
Catalog Number
Dimensions - inches (mm)
Output 1
Output 2
Output 3
Case
SLS-05-030-1T
5 V @ 3 A*#
–
–
A
SLS-05-060-1T
5 V @ 6 A*#
–
–
B1
SLS-05-090-1T
5 V @ 9 A*#
–
–
C
SLS-05-120-1T
5 V @ 12 A*#
–
–
I2
SLS-12-017T1
12 V @ 1.7 A# or
15 V @ 1.5 A
–
–
A
SLS-12-034T
12 V @ 3.4 A#
–
–
B1
SLS-12-051T
12 V @ 5.1 A#
–
–
C
SLS-12-068T
12 V @ 6.8 A#
–
–
I2
SLS-15-045T
15 V @ 4.5 A#
–
–
C
SLS-15-060T
15 V @ 6 A#
–
–
I2
SLS-24-012T
24 V @ 1.2 A#
–
–
A
SLS-24-024T
24 V @ 2.4 A#
–
–
B2
SLS-24-036T
24 V @ 3.6 A#
–
–
C
SLS-24-048T
24 V @ 4.8 A#
–
–
I2
SLS-24-072T
24 V @ 7.2 A#
–
–
K
SLS-24-120T
24 V @ 12.0 A#
–
–
L
SLD-12-1010-12T1
12 V @ 1 A or 15
V @ .8 A
-12 V @ 1 A or
-15 V @ .8
–
H1
SLD-12-1818-12T1
12 V @ 1.8 A or
15 V @ 1.5 A
-12 V @ 1.8
A or -15 V @
1.5 A
–
D
SLD-12-3434-12T
12 V @ 3.4 A#
-12 V @ 3.4 A#
–
I3
SLD-15-3030-15T
15 V @ 3 A#
-15 V @ 3 A#
–
I3
SLD-12-6034-05T
5 V @ 6 A*#
12 V @ 3.4 A#
–
I1
SLD-12-3015-05T
5 V @ 3 A*#
12 [email protected] 1.5 A
–
C1
SLT12-20404-12T1
5 V @ 2 A*#
12 V @ .4 A or
15 V @ .4 A
-12 V @ .4 A or
-15 V @ .4 A
H2
SLT12-31010-12T1
5 V @ 3 A*#
12 V @ 1 A# or
15 V @ .8 A
-12 V @ 1 A#
or -15 V @ .8 A
F
SLT12-61010-12T1
5V @ 6 A*#
12 V @ 1 A or
15 V @ 1 A
-12 V @ 1 A or
-15 V @ 1 A
I4
SLT12-61818-12T1
5V @ 6A*#
12 V @1.8 A or
15 V @1.5 A
-12 V @ 1.8
A or -15 V @
1.5 A
G2
SLT24-30530-05T
5V @ 3A*
-5 V @ .5 A*
24 V @ 3 A
G1
Over Voltage Protector (OVP)
SLO-12-000-1
SLO-12-000-TB
6.2 V to 34 V
Adjustable @ 8 A
6.2 V to 34 V
Adjustable @ 8 A
For Cases B through K
For Case A or Cases B through K
(when used with a cover)
J1
J2
Case A
Case B
Cover Options
Catalog
Number
Description
Catalog
Number
Description
SLCASA-CVR
Cover for Case A
SLCASG-CVR
Cover for Cases G1 and G2
SLCASB-CVR
Cover for Case B
SLCASH-CVR
Cover for Cases H1 and H2
SLCASC-CVR
Cover for Case C
SLCASI-CVR
Cover for Cases I1, I2, I3 and I4
SLCASC1-CVR
Cover for Case C1
SLCASK-CVR
Cover for Case K
SLCASD-CVR
Cover for Case D
SLCASL-CVR
Cover for Case L
SLCASF-CVR
Cover for Case F
Note:
Covers are sold separately. When used, derate the power supply by 15% of its
rated value.
Notes:
* With Built-In OVP
# With Remote Sense (R.S.)
1
12/15 Volt models are factory set for 12 Volt operation. 15 Volt operation is field
adjustable.
Visit our website at www.solaheviduty.com or
Contact Technical Services at (800) 377-4384 with any questions.
111
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
4
Power Supplies
Silver Line Dimensions (inches/mm)
Case F
Cases C and C1
Cases G1 and G2
Case D
AC Input Jumper Connections
AC Input Jumper Connections
For use at:
100 VAC
120 VAC
220 VAC
230/240 VAC
Connect:
1-3, 2-4
1-3, 2-4
2-3
2-3
Apply AC:
1&5
1&4
1&5
1&4
Cases H1 and H2
112
Visit our website at www.solaheviduty.com or
contact Technical Services at (800) 377-4384 with any questions.
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
4
Power Supplies
Silver Line Dimensions (inches/mm)
Case J1
Case J2
��� ����������
�� �������� ������
������ �����
���� ������
������ �����
������ ����
���� ����
���� ����
���� ������
����� �����
������ �����
���
� ����
���� ������
����� �����
����� ����
������ ����
� ���
Cases I1, I2, I3 and I4
� � �� �
� ���
��
��
� ��� ����� ��� �������
�� �����
������� ��� ����
���� ���
���� ����
��� ��� �����
���� ��� �� �������
Case K
Notes:
All dimensions in inches (mm). Dimensions may change and should not be used for
construction purposes.
Be sure to specify the complete part number when ordering. Orders may be placed
with your local Sola/Hevi-Duty distributor.
������� �� ����
����� ���
�� �������� ������
������ �����
������ �����
����� � ����
����� �����
� ���� ������
����� ����
� ����
� ���� ����
��� ����������
� ����
� ��� ����� ��� �������
�����
� ��� ����
� ���
��
��
� ���
����� ����
� ��� ���� �� ��
����� ����
� ��� ����
����� ����
� � � ��
�� �����
���� ����
Case L
Visit our website at www.solaheviduty.com or
Contact Technical Services at (800) 377-4384 with any questions.
113
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
4
Power Supplies
Linear OEM – Single Output
Applications
•
•
•
•
Microprocessor circuits
Process controls
Control circuits
Noise sensitive circuits
• Instrumentation
• CNC machinery
• Analog circuits
Specifications
Parameter
Condition
Limit
Input
UL 1950
E137632
Input Frequency
Features
50-60 Hz
Output
• Low noise output
• 115/230 VAC input
• Remote sensing
• Designed for both bench and rack use
• Completely protected short circuit proof; automatic
foldback.
• Current limiting – automatic reset
• Isolated floating output
• UL Recognized, CSA Certified
• Built-in OVP on 5 Volt models
• Terminal block on Case D models (24 V/6 A)
• One year warranty
Selection Table
114
104-127 VAC
208-254 VAC
Input Voltage
Catalog Number
Output 1
Case
83-05-230-3
5 V @ 3.0 A
B
83-12-218-3
12 V @ 1.8 A
B
83-24-212-3
24 V @ 1.2 A
B
83-05-260-3
[email protected]
C
83-12-250-3
12 V @ 5 A
C
83-24-225-3
24 V @ 2.5 A
C
83-05-312-3
5 V @ 12 A
D
83-12-310-3
12 V @ 10 A
D
83-24-260-3
24 V @ 6 A
D
Regulation Line & Load
±0.1%
Pard (Ripple and Noise)
0.1% pk/pk
Periodic Deviations
(Ripple)
10mv rms
Output Voltage Adjustment
Transient Recovery Time
±5% Minimum
50%-100% Load
Less than 50 msec
General
Storage Ambient Temp.
Operating Ambient Temp.
Temp. Effect Coefficient
-40°C to +85°C
0°C to +50°C
0.03% °C
Polarity
May be used
positive or negative
Short Circuit Protection
Protected with
Automatic Recovery
Maximum Allowable Lead
Drop for Remote Sensing
5%
Maximum Output Current
120% Rated Current
Maximum Short Circui
Current
30% Rated Current
Input/Output Isolation
1000 Megohms
D.C., 2500 VAC
Cooling
Forced air. 20 CFM required for full
rating Derate 30% without cooling
Visit our website at www.solaheviduty.com or
contact Technical Services at (800) 377-4384 with any questions.
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
Power Supplies
4
Linear OEM Cases and Dimensions
Case D
Notes:
All dimensions in inches (mm). Dimensions may change and should not be used for
construction purposes.
Case B
When ordering, be sure to specify the complete part number. Orders may be placed
with your local Sola/Hevi-Duty distributor.
Case C
Visit our website at www.solaheviduty.com or
Contact Technical Services at (800) 377-4384 with any questions.
115
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
4
Power Supplies
GL Series: Single & Multi Output Switchers
Specifications
Parameter
Condition
Limit
Input
Input Voltage
85 to 264 VAC
Frequency
47 to 63 Hz
Protection
Line Fuse on board
Inrush Current
Cold Start
15 to 60 A Max
Output
Line Regulation
200 Watt model
40, 65, 100 Watt models
These compact, low profile, AC/DC switching power
supplies offer universal input voltage with no switches or
jumpers, ideal for higher volume worldwide applications.
40 watt through 110 watt are printed circuit board design
with pin and socket connections, 200 watt models are
enclosed with internal DC brushless fan and screw
terminal connections.
Features
•
•
•
•
•
•
•
•
•
•
•
Load Regulation
Full Rated Load
Cross Regulation
Full Rated Load
5% Typical
Minimum Loading
Main Output
Temp. Coefficient
Industrial computers
Control
Instrumentation
Scanners
•
•
•
•
10%
±0.04%/ °C
Hold up Time
10 mS min.
Overvoltage
Protection
112 to 132%
of Nominal
#1 Output
Output Ripple
2% peak to peak max.
General
Full Rated Load
Storage Temperature
Efficiency
MTBF
0 to 50°C
-20 to +85°C
Full Rated Load
Per MIL-HDBK-217E
65% min.
100,000 hour
Designed to meet
MIL-STD 810C
Shock & Vibration
FCC20780 Level B &
VDE 0871 Level A
EMI
Safety
All Models
UL 1950, CSA C22.2
No. 234, EN 60950
Cooling
Full Load
Convection Cooling
200 W units have an
internal fan
Mating Connector Kits
Applications
• Can be ordered separately for units with Molex
connection (40, 65 and 110 watt units only).
• Kits include mating housing and pins for input and
output connection.
Drive circuits
CNC machinery
Printers
Peripherals
Auxiliary Signal Connector - 200 watt units only
Connector Kits
Catalog
Number
Applicable
Models
Input/Output
Mating Connector
Signal
Connector
GL40-KIT
40 Watt
X
N/A
GL65-KIT
65 Watt
X
N/A
GL110-KIT
110 Watt
X
N/A
GL200-KIT
200 Watt
N/A
X
116
±0.5%
±1% Single Output
±2% Main Output
Operating Temperature
Universal input
Compact size
Industry standard size (3 x 5”, 40 Watt)
On board input fuse
Automatic overload protection
OVP on Output #1
UL Recognized, CSA Certified, CE, LVD
100% Burn-In
One year warranty
Power fail signal on 110 and 200 Watt model
200 Watt enclosed with screw terminals
•
•
•
•
Full Rated Load
Model
Pin 1
Pin 2
Pin 3
Pin 4
All 200 Watt Models
Fan
Common
Common
Power Fail
Auxiliary Mating Connector Kit for 200 watt units
Kit is for auxiliary signal connection only. Not required for
input and output connection which are screw terminal.
Visit our website at www.solaheviduty.com or
contact Technical Services at (800) 377-4384 with any questions.
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
4
Power Supplies
Output 1
Output 2
Output 3
Maximum
Output
GLS-01-040
5 V, 6A
-
-
30 W
GLS-02-040
12 V, 3.5 A
-
-
40 W
GLS-03-040
15 V, 3A
-
-
40 W
GLS-04-040
24 V, 2 A
-
-
40 W
GLD-01-040
5 V, 3 A
12 V, 2 A
-
40 W
GLD-02-040
5 V, 3 A
15 V, 2 A
-
40 W
GLD-03-040
5 V, 3 A
24 V, 1 A
-
40 W
GLT-01-040
5 V, 3 A
12 V, 2 A
-5 V, 0.3 A
40 W
GLT-02-040
5 V, 3 A
12 V, 2 A
-12 V, 0.3 A
40 W
GLT-03-040
5 V, 3 A
15 V, 2 A
-15 V, 0.3 A
40 W
GLT-04-040
5 V, 3 A
15 V, 2 A
-12 V, 0.3 A
40 W
GLT-05-040
5 V, 3 A
24 V, 1 A
-12 V, 0.3 A
40 W
0.157 (4.0) MOUNTING HOLE (4 PL)
1
DC
OUTPUT
AC
INPUT
P1
N
6
3.00 (76.2)
Catalog
Number
Dimensions for 40 Watt, GL Series
2.55 (64.8)
Selection Table for 40 Watt, GL Series
L
0.20 (5.0)
0.20 (5.0)
4.55 (115.6)
5.00 (127.0)
1.18 (30.0) 1.36 (34.5)
Notes:
1. Tolerance 0.02/0.5 maximum.
2. Input connector Molex # 09-50-3031 and Molex series 2578 # 08-50-0105 crimp
terminal using Molex # 63811-2200 hand applicator.
Output Connector
Model
Pin 1
Pin 2
Pin 3
Pin 4
Pin 5
Pin 6
GLS
Output 1
Output 1
Output 1
Return
Return
Return
GLD
Output 2
Output 1
Output 1
Common
Common
N/A
GLT
Output 2
Output 1
Output 1
Common
Common
Output 3
Selection Table for 65 Watt, GL Series
3. Output connector Molex# 09-50-3061 and Molex series 2578 # 08-50-0105 crimp
terminal using Molex # 63811-2200 hand applicator.
4. Weight: 10.6 oz. (300 grams) approx.
5. Input/Output Mating Connector kit available. Catalog number GL40-KIT.
6. All dimensions in inches (mm).
Dimensions for 65 Watt, GL Series
Output 4
Maximum
Output
GLS-01-065
5 V, 10 A
-
-
-
50 W
GLS-02-065
12 V, 5.5 A
-
-
-
65 W
GLS-03-065
15 V, 4.5 A
-
-
-
65 W
GLS-04-065
24 V, 3 A
-
-
-
65 W
GLD-01-065
5 V, 6 A
12 V, 3 A
-
-
65 W
GLD-02-065
5 V, 6 A
15 V, 3 A
-
-
65 W
GLD-03-065
5 V, 6 A
24 V, 2 A
-
-
65 W
GLT-01-065
5 V, 6 A
12 V, 3 A
-5 V, 0.5 A
-
65 W
GLT-02-065
5 V, 6 A
12 V, 3 A
-12 V, 0.5 A
-
65 W
GLT-03-065
5 V, 6 A
15 V, 3 A
-15 V, 0.5 A
-
65 W
GLT-04-065
5 V, 6 A
15 V, 3 A
-12 V, 0.5 A
-
65 W
GLT-05-065
5 V, 6 A
24 V, 2 A
-12 V, 0.5 A
-
65 W
GLQ-01-065
5 V, 6 A
12 V, 3 A
-12 V, 0.5 A
-5 V, 0.5 A
65 W
0.157 (4.0) DIA. MOUNTING HOLD (4PL)
L
N
P1
AC
INPUT
0.18 (4.5)
Output 3
8
DC
OUTPUT
P2
1
0.59 (15.0)
4.80 (122.0)
6.00 (152.6)
1.77 (45.0)
0.10 (2.5)
Output 2
3.50 (89.0)
Output 1
3.15 (80.0)
Catalog
Number
Notes:
1. Tolerance 0.02/0.5 maximum.
2. Input connector Molex # 09-50-3031 and Molex series 2578 # 08-50-0105 crimp
terminal using Molex # 63811-2200 hand applicator.
Output Connector
Model
Pin 1
Pin 2
Pin 3
Pin 4
Pin 5
Pin 6
Pin 7
Pin 8
GLS
Output 1
Output 1
Output 1
Output 1
Return
Return
Return
Return
GLD
Output 1
Output 1
Common
Common
Output 2
Output 2
N/A
N/A
GLT
Output 1
Output 1
Common
Common
Output 2
Output 2
Output 3
N/A
GLQ
Output 1
Output 1
Common
Common
Output 2
Output 2
Output 3
Output 4
3. Output connector Molex # 09-50-3081 and Molex series 2578 # 08-50-0105 crimp
terminal using Molex # 63811-2200 hand applicator.
4. Weight: 13.4 oz. (380 grams) approx.
5. Input/Output Mating Connector kit available. Catalog number GL65-KIT.
6. All dimensions in inches (mm).
Visit our website at www.solaheviduty.com or
Contact Technical Services at (800) 377-4384 with any questions.
117
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
4
Power Supplies
GL Series: Single & Multi Output Switchers – continued
Dimensions for 110 Watt, GL Series
Selection Table for 110 Watt, GL Series
Catalog
Number
Output 1
Output 2
Output 3
Output 4
Maximum
Output*
GLS-01-110
5 V, 22 A
-
-
-
110 W
GLS-02-110
12 V, 9 A
-
-
-
110 W
GLS-03-110
15 V, 7.5 A
-
-
-
110 W
GLS-04-110
24 V, 4.5 A
-
-
-
110 W
GLD-01-110
5 V, 10 A
12 V, 5 A
-
-
110 W
GLT-01-110
5 V, 10 A
12 V, 3 A
-12 V, 1 A
-
110 W
GLT-02-110
5 V, 10 A
15 V, 4 A
-15 V, 1 A
-
110 W
GLQ-01-110
5 V, 10 A
12 V, 5 A
-12 V, 1 A
-5 V, 1 A
110 W
GLQ-02-110
5 V, 10 A
12 V, 5 A
-12 V, 1 A
+12 V, 1 A
110 W
GLQ-03-110
5 V, 10 A
12 V, 5 A
-12 V, 1 A
+24 V, 1 A
110 W
GLQ-04-110
5 V, 10 A
15 V, 4 A
-15 V, 1 A
-5 V, 1 A
110 W
* With 25 CFM airflow, 80 W with convention cooling.
Output Connector
Model
Pin 1-2-3
Pin 4-5
Pin 6-7
Pin 8-9
Pin 10
Pin 11
Pin 12
Pin 13
GLS
Output 1
Return
Return
Output 1
Power Fail
N/A
Key
N/A
GLD
Output 1
Common
Common
Output 2
Power Fail
N/A
Key
N/A
GLT
Output 1
Common
Common
Output 2
Power Fail
Output 3
Key
N/A
GLQ
Output 1
Common
Common
Output 2
Power Fail
Output 3
Key
Output 4
Output 1
Output 2
Output 3
Output 4
Maximum
Output
GLS-01-200
5 V, 40 A
-
-
-
200 W
GLS-02-200
12 V, 16.7 A
-
-
-
200 W
GLS-03-200
15 V, 13.4 A
-
-
-
200 W
GLS-04-200
24 V, 8.4 A
-
-
-
200 W
GLD-01-200
5 V, 30 A
12 V, 8 A
-
-
200 W
GLD-02-200
5 V, 30 A
15 V, 6 A
-
-
200 W
GLD-03-200
5 V, 30 A
24 V, 4 A
-
-
200 W
GLT-01-200
5 V, 30 A
12 V, 8 A
-5 V, 6 A
-
200 W
GLT-02-200
5 V, 30 A
12 V, 8 A
-12 V, 4 A
-
200 W
GLT-03-200
5 V, 30 A
15 V, 6 A
-15 V, 4 A
-
200 W
GLT-04-200
5 V, 30 A
15 V, 6 A
-12 V, 4 A
-
200 W
GLQ-01-200
5 V, 30 A
12 V, 8 A
-12 V, 4 A
5 V, 6 A
200 W
GLQ-02-200
5 V, 30 A
15 V, 6 A
-15 V, 4 A
24 V, 4 A
200 W
GLQ-03-200
5 V, 30 A
12 V, 8 A
-12 V, 4 A
12 V, 4 A
200 W
GLQ-04-200
5 V, 30 A
12 V, 8 A
-15 V, 4 A
15 V, 4 A
200 W
GLQ-05-200
5 V, 30 A
12 V, 8 A
-12 V, 4 A
24 V, 4 A
200 W
Output Connector (Terminal Block)
Model
Pin 1-2
Pin 3-4-5
Pin 6
Pin 7
Pin 8
Pin 9
GLS
- Sense
Return
Output 1
Output 1
Output 1
+Sense
GLD
Output 1
Common
Output 2
N/A
N/A
N/A
GLT
Output 1
Common
Output 2
Output 3
N/A
N/A
GLQ
Output 1
Common
Output 2
Output 3
Output 4 Return
Output 4
118
6. All dimensions in inches (mm).
Dimensions for 200 Watt, GL Series
Selection Table for 200 Watt, GL Series
Catalog
Number
Notes:
1. Tolerance 0.02 (0.5) maximum.
2. Input connector Molex # 09-50-3051 and Molex series 2578 # 08-50-0105 crimp
terminal using Molex # 63811-2200 hand applicator.
3. Output connector Molex # 09-50-3131 and Molex series 2578 # 08-50-0105 crimp
terminal using Molex # 63811-2200 hand applicator.
4. Weight: 1.32 lbs. (600 grams) approx.
5. Input/Output Mating Connector kit available. Catalog number GL110-KIT.
Notes:
1. Tolerance 0.02 (0.5) maximum.
2. Connector Molex # 22-01-2041 and Molex series 2759 # 08-50-0113 crimp
terminal using Molex # 11-01-0185 hand applicator.
3. Connectors P3 mates with Molex housing 22-01-1043 and Molex 4809 series
crimp terminal.
4. Weight: 3.9 lbs. (1,750 grams) approx.
5. All dimensions in inches (mm).
Visit our website at www.solaheviduty.com or
contact Technical Services at (800) 377-4384 with any questions.
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
4
Power Supplies
SMP Series: Super Slim Modular Power Supplies
These medium power, modular power supplies, from 250
through 1000 watts, are capable of up to 12 independent
outputs. Modular design makes these units easy to
customize for unusual voltage and power combinations.
All units have power factor corrected inputs, an end
mounted fan for cooling and a variety of built-in signals and
controls. High reliability and a flexible design make these
an excellent choice for process control and
semiconductor fabrication applications.
Features
• Worldwide safety agency approval
(UL, CSA and CE)
• 250, 350, 450, 600 & 1000 Watt Power Platforms
• Meets IEC1000-3-2
• Power Factor Corrections (0.99)
• Universal AC Input (90-264V)
• Single wire current share
• Power fail TTL signal
• Cover and End mounted fan
• Capable of up to 12 independent outputs
• Highly accelerated life tested (HALT)
• Fully isolated outputs
• Two year warranty
• Thermal overload protection
• MTBF demonstrated >500,000 hours
UL 60950
E137632
Applications
• Process Control
• Semiconductor Fabrication
• Low Profile Chassis Mount
• Service Automation
Related Products
• GL Series
• SHP Series
Visit our website at www.solaheviduty.com or
Contact Technical Services at (800) 377-4384 with any questions.
119
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
4
Power Supplies
Specifications
Description
Catalog Number
SM2
SM3
SM4
SM6
SM9
Input
AC Input
90-264 VAC, 47-63 Hz single phase
Inrush Current
Less than 20 A peak
Less than 40 A peak
PFC and Harmonic
Correction
Compliant with EN61000-3-2.
Input Transient and
ESD, AC
Compliant with EN61000-4-2,3,4,5,6 (Level 3 minimum)
Output
Line Regulation
AC input
Less than 0.1% for line variations from 90-264 VAC Less than 0.3% for dual and triple output modules
Load Regulation
Less than 1.0% no load to full load and full load to no load, mains. Less than 2.0% for dual and triple output modules
Cross Regulation
Less than 0.1% between single output modules. Less than 2% between dual outputs with 25% step load change on main output.
Current Share
Output Adjustment
Range
Single wire on all main outputs, droop on secondary outputs
Single wire parallel current share
±10% of nominal on all Main outputs 5 -15 volts
on U and T module Auxiliary outputs
±5% min on all outputs
Current Limit
Overvoltage
Protection
Minimum Load
Dynamic Response
140% nominal rating.
OVP is standard on all Main Output Modules and low voltage
secondary outputs. 120-130% of nominal.
OVP is standard on all Main Output Modules and low
voltage secondary outputs. 115-130% of nominal.
No preload is required on any Single, Dual output module. A min 1A, max 10% preload is required on main output of
Triple and Slim-Line Dual (U) outputs in order to achieve specified regulation.
±25% load change from a steady state 75% of nominal at a rate of 1A/µsec will result in an output deviation no greater than 2% or 100mV peak.
125mV for outputs 4V or less. Outputs should recover to within 1% of nominal voltage within 350µsec.
General
Efficiency
EMC
75% typical at nominal line. 24 V+ single outputs 80%
75% typical at nominal line.
Radiated and Conducted per CISPR 11 level B, CE compliant.
EN55022 Class B, EN61000-4-2, 3, 4, 5 & 6 Level 3
Temperature
Coefficient
Holdup Time,
AC Input
Remote Sense
0.02 - 0.03%/°C
All AC Input units will maintain regulation within specifications for a period of not less than
16 msec for 60Hz, (20msec for 50Hz) at full rated load from nominal 115/230 line voltage.
All AC Input units will maintain regulation within
specifications for a period of not less than 16msec for
60Hz, (20msec for 50Hz) at full rated load
from nominal 230 line voltage.
All main outputs incorporate remote sense and are able to
compensate for a total cable drop up to 0.5V DC.
All single output, main output on triple outputs and dual
output “D” modules incorporate remote sense and are able
to compensate for a total cable drop up to 0.5V DC. Dual
output “G” modules do not have remote sense.
Cooling
Temperature performance curves are available. Contact Technical Services.
Operating
Temperature Range
0 to +70°C (full power to 50°C, derate linearly to 50% at 70°C).
Storage
Temperature
-40° to +85°C
Operating Altitude
-350 to 7,500 feet with no derating
Shock and Vibration
Commercial transportation ratings, suitable for International Air and Ground transport
Dimensions
Mounting
HxWxD
(inches/mm)
Weight (lbs/g)
120
All platforms - two surfaces, bottom and one side
Chassis mount via threaded M4 holes on two surfaces.
1.56 in x 5 in x 9.5 in
(40 mm x 127 mm x 241 mm)
1.56 in x 5 in x 10.5 in
(40 mm x 127 mm x 266 mm)
1.68 in x 5 in x 10.5 in
(43 mm x 127 mm x 266 mm)
2.5 in x 5 in x 11 in
(64 mm x 127 mm x 280 mm)
2.5 in x 7 in x 11 in
(64 mm x 178 mm x 280 mm)
2.3 lbs (1200 g), Unit
3.5 lbs (1588 g) Shipping
2.9 lbs (1315 g), Unit
4.0 lbs (1814 g), Shipping
3.0 lbs (1360 g), Unit
4.5 lbs (2041 g), Shipping
3.2 lbs (1451g), Unit
4.8 lbs (2177g), Shipping
4.4 lbs (1996 g), Unit
6.6 lbs (2994 g), Shipping
Visit our website at www.solaheviduty.com or
contact Technical Services at (800) 377-4384 with any questions.
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
4
Power Supplies
Selection Tables
350 Watt, SM3 Series
250 Watt, SM2 Series
Catalog
Number
Output 1
Output 2
Output 3
Maximum
Output
Catalog
Number
Output 1
Output 2
Output 3
Output 4
Maximum
Output
SM2-S3
5 V, 50 A
250 W
SM3-S3R1
5 V, 50 A
12 V, 6 A
12 V, 6 A
350 W
SM2-S4
12 V, 20 A
250 W
SM3-S3R2
5 V, 50 A
15 V, 5 A
15 V, 5 A
350 W
SM2-S5
15 V, 16.6 A
250 W
SM3-U4R1
5 V, 40 A
12 V, 6 A
12 V, 6 A
24 V, 2.5 A
350 W
SM2-S6
24 V, 10 A
250 W
SM3-U4R2
5 V, 40 A
15 V, 5 A
15 V, 5 A
24 V, 2.5 A
350 W
SM2-S7
28 V, 9 A
250 W
SM3-U2R6
5 V, 40 A
12 V, 6 A
12 V, 4A
5 V, 8 A
350 W
SM2-S9
48 V, 5 A
SM2-R2
15 V, 5 A
15 V, 5 A
250 W
SM2-U4
5 V, 40 A
24 V, 2.5 A
250 W
SM2-T1
5 V, 20 A
12 V, 4 A
12 V, 4 A
250 W
SM2-T2
5 V, 20 A
15 V, 3 A
15 V, 3 A
250 W
250 W
450 Watt, SM4 Series
Catalog Number
Output 1
Output 2
5 V, 50 A
5 V, 50 A
450 W
SM4-S3S6
5 V, 50 A
24 V, 10 A
450 W
SM4-S6S6
24 V, 10 A
24 V, 10 A
SM4-U2S3
5 V, 40 A
5 V, 50 A
12 V, 4 A
SM4-T6S3
5 V, 50 A
12 V, 10 A
12 V, 4 A
5 V, 4 A
SM4-U4T6
5 V, 40 A
12 V, 10 A
12 V, 4 A
5 V, 4 A
Output 3
Output 4
SM4-S3S3
Output 3
Output 4
Output 5
Maximum Output
450 W
450 W
450 W
24 V, 2.5 A
450 W
600 Watt, SM6 Series
Catalog Number
Output 1
Output 2
Maximum Output
SM6-C3
5 V, 100 A
600 W
SM6-C6
24 V, 21 A
600 W
SM6-C7
28 V, 18 A
600 W
SM6-C9
48 V, 10.5 A
600 W
SM6-B3B3
5 V, 60 A
5 V, 60 A
SM6-G3C3A4
5 V, 100 A
12 V, 10 A
12 V, 4 A
5 V, 8 A
600 W
600 W
SM6-B3A3A4A4
5 V, 60 A
12 V, 10 A
12 V, 10 A
5 V, 20 A
600 W
SM6-B3A3A5A5
5 V, 60 A
15 V, 8 A
15 V, 8 A
5 V, 20 A
600 W
SM6-A3A5A5A6
5 V, 20 A
15 V, 8 A
15 V, 8 A
24 V, 6 A
600 W
1000 Watt, SM9 Series
Catalog Number
Output 1
Output 2
Output 3
Output 4
Output 5
Maximum Output
SM9-C6C6
24 V, 42 A
1000 W
SM9-C3C3
5 V, 100 A
5 V, 100 A
SM9-D1C3B4
5 V, 100 A
12 V, 25 A
12 V, 10 A
5 V, 10 A
1000 W
SM9-B3B4A4A6
5 V, 60 A
12 V, 25 A
12 V, 10 A
24 V, 6 A
1000 W
SM9-B3B5A5A6
5 V, 60 A
15 V, 20 A
15 V, 8 A
24 V, 6 A
SM9-E3C3B4
5 V, 100 A
12 V, 25 A
12 V, 10 A
15 V, 2 A
-15 V, 2 A
1000 W
SM9-D3B3B4B4
5 V, 60 A
12 V, 25 A
12 V, 25 A
5 V, 10 A
24 V, 5 A
1000 W
SM9-D3B3B5B5
5 V, 60 A
15 V, 20 A
15 V, 20 A
5 V, 10 A
24 V, 5 A
1000 W
SM9-E1C3A6
5 V, 100 A
5 V, 20 A
12 V, 2 A
-12 V, 2 A
24 V, 6 A
1000 W
1000 W
1000 W
More models available online. Visit http://www.solaheviduty.com/psselect/ and use our modular power supply selector.
Visit our website at www.solaheviduty.com or
Contact Technical Services at (800) 377-4384 with any questions.
121
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
4
Power Supplies
Mechanical Dimensions
M3-0.5 THD
Additional Mtg. Hole if required
0.15 Max. Screw Penetration
8.30
1.50
9.50
1.56
5.500
.75
2.50
3.500
5.00
4X M4-0.7 THD
0.15 Max. Screw Penetration
1.50
Air Flow
Power Supply
Output Termination Area
2X M4-0.7 THD
0.15 Max. Screw Penetration
5.500
ACL
ACN
ACG
.75
AC Input
3 Position Terminal Block
SM2
M3-0.5 THD
Additional Mtg. Hole if required
0.15 Max. Screw Penetration
9.30
1.50
10.50
1.56
6.000
.75
2.50
5.00
3.500
4X M4-0.7 THD
0.15 Max. Screw Penetration
1.50
Power Supply
Output Termination Area
2X M4-0.7 THD
0.15 Max. Screw Penetration
6.000
ACL
ACN
ACG
.75
Air Flow
AC Input
3 Position Terminal Block
SM3
1.50
1.68
1.56
6.000
10.50
.75
3.500
Air Flow
5.00
ACL
ACN
ACG
4X M4-0.7 THD
0.15 Max. Screw Penetration
1.56
2X M4-0.7 THD
0.15 Max. Screw Penetration
AC Input
3 Position Terminal Block
Power Supply
Output Termination Area
8.000
.75
SM4
122
Visit our website at www.solaheviduty.com or
contact Technical Services at (800) 377-4384 with any questions.
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
4
Power Supplies
Mechanical Dimensions - continued
.33 Max Before Adding Terminal Lugs
2X M4 x 0.7 THD 0.15 Max.
Screw Penetration
10.200
.40
M4 x 0.7 THD Output
Hardware, Typ.
1.250
Optional Output Connectors
(Consult Technical Service)
Voltage Adjust, Typ.
11.00
-
2.50
10.200
+
.40
5.00
+
-
.40
Multi Output Connector
Molex PN 39-30-1080
Air Flow
4.200
2X M4 x 0.7 THD
0.15 Max.
Screw Penetration
Logic Connector, Typ
AMP PN 102617-3
AC Input Terminal Block
Number 6 Hardware, 0.375 Centers
Optional Input Connector
SM6
.33 Max Before Adding Terminal Lugs
2X M4 x 0.7 THD
0.15 Max. Screw Penetration
9.250
.40
1.250
M4 x 0.7 THD Output
Hardware, Typ.
Optional Output Connectors
(Consult Technical Service)
Voltage Adjust, Typ.
11.00
.40
2.50
9.250
-
+
-
+
.40
Air Flow
-
+
7.00 6.200
Multi Output Connector
Molex PN 39-30-1080
Logic Connector, Typ
AMP PN 102617-3
2X M4 x 0.7 THD
0.15 Max. Screw Penetration
AC Input Terminal Block
Number 6 Hardware, 0.375 Centers
Optional Input Connector
SM9
Visit our website at www.solaheviduty.com or
Contact Technical Services at (800) 377-4384 with any questions.
123
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
4
Power Supplies
SHP Series: Heavy Duty Modular Power Supplies
These high power, modular power supplies, from 1500
through 2000 watts, are capable of up to 12 independent
outputs. Modular design makes these units easy to
customize for unusual voltage and power combinations.
All units have power factor corrected inputs, an end
mounted fan for cooling and a variety of built-in signals and
controls. High reliability and a flexible design make these
an excellent choice for process control and
semiconductor fabrication applications.
Features
•
•
•
•
•
•
•
•
•
•
•
•
•
Capable of up to 12 outputs
Single output 24 V up to 87.4 A
IEC 801 immunity standards
Current Share on all outputs
End mounted fan
Voltage adjustment on all outputs
Overload protection on all outputs
Two year warranty
Power factor correction (.99 typ.)
Margining on all outputs
Modular Construction
Global and individual module inhibits/enable
Single phase and three phase inputs
Applications
• Process Controls
• Semi-conductor Fabrication
• Automated Service Equipment
UL 60950
E137632
Specifications
Parameter
Condition
Input
Input Voltage
SH Series
86 to 264 VAC (1Ø)
S3H Series
180 to 264 (3Ø)
Frequency
47 to 440 Hz
Protection
Internally Fused
Inrush Current
40A Max
Output
Line Regulation
Full Rated Load
0.2% or 5mV max
Load Regulation
Full Rated Load
0.2% or 5mV max
Minimum Loading
Where indicated
Temp. Coefficient
Hold up Time
±0.02%/ °C
Full Rated Load
Overvoltage Protection
Related Products
Short-Circuit Protection
• SMP Medium Power Modular Power Supplies
• Surge Suppression
• SCD DC to DC Converters
Output Ripple
No less than 20ms
2-5 V 122% to 134%
Continuous
Protected for shortcircuit, auto-recovery
0.1% or 10mV RMS
General
Operating Temperature
Full Rated Load
Storage Temperature
Efficiency
Full Rated Load
75% to 82%
>500,000 hours
Shock & Vibration
MIL-HDBK 810E
CISPR 22, EN55022
Level B
EMI
Safety
-10 to 50°C
-55 to +85°C
MTBF
All Models
Cooling
124
Limit
UL, CE and CSA
Internal DC fan 24
Visit our website at www.solaheviduty.com or
contact Technical Services at (800) 377-4384 with any questions.
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
4
Power Supplies
Selection Tables
Single Phase 1500 Watt, SH15 Series
Catalog
Number
Output 1
SH15-Q2
3.3 V, 300 A
1500 W
SH15-Q3
5 V, 300 A
1500 W
SH15-Q4
12 V, 125 A
1500 W
SH15-Q5
15 V, 100 A
1500 W
SH15-Q6
24 V, 62.4 A
1500 W
SH15-Q7
28 V, 53.4 A
1500 W
SH15-Q8
36 V, 41.6 A
1500 W
SH15-Q9
48 V, 31.2 A
1500 W
SH20-P3T53J4
5 V, 150 A
24 V, 10.5 A
12 V, 25 A
12 V, 20 A
1500 W
SH20-P3T54J5
5 V, 150 A
24 V, 10.5 A
15 V, 20 A
15 V, 20 A
1500 W
Output 2
Output 3
Output 4
Maximum Output
Single Phase 2000 Watt, SH20 Series
Catalog
Number
Output 1
SH20-Q3K3-7
5 V, 420 A
2000 W
SH20-Q6K6-7
24 V, 87.4 A
2000 W
SH20-Q9K9-7
48 V, 43.7 A
2000 W
Output 2
SH20-M3K2
5 V, 240 A
3.3 V, 120 A
SH20-Z6Z7M3
5 V, 240 A
12 V, 21 A
Output 3
Output 4
Output 5
Output 6
Maximum
Output
2000 W
12 V, 20 A
5 V, 50 A
15 V, 10 A
24 V, 5 A
2000 W
Three Phase 1500 Watt, S3H15 Series
Catalog
Number
Output 1
S3H15-Q2
3.3 V, 300 A
1500 W
S3H15-Q3
5 V, 300 A
1500 W
S3H15-Q4
12 V, 125 A
1500 W
S3H15-Q5
15 V, 100 A
1500 W
S3H15-Q6
24 V, 62.4 A
1500 W
S3H15-Q7
28 V, 53.4 A
1500 W
S3H15-Q8
36 V, 41.6 A
1500 W
Output 2
Output 3
Output 4
Maximum Output
S3H15-Q9
48 V, 31.2 A
S3H20-P3T53J4
5 V, 150 A
24 V, 10.5 A
12 V, 25 A
12 V, 20 A
1500 W
1500 W
S3H20-P3T54J5
5 V, 150 A
24 V, 10.5 A
15 V, 20 A
15 V, 20 A
1500 W
Three Phase 2000 Watt, S3H20 Series
Catalog
Number
Output 1
Output 2
Output 3
Output 4
Output 5
Output 6
Maximum
Output
S3H20-Q3K3-7
5 V, 420 A
2000 W
S3H20-Q6K6-7
24 V, 87.4 A
2000 W
S3H20-Q9K9-7
48 V, 43.7 A
2000 W
S3H20-M3K2
5 V, 240 A
3.3 V, 120 A
S3H20-Z6Z7M3
5 V, 240 A
12 V, 21 A
2000 W
12 V, 20 A
5 V, 50 A
15 V, 10 A
Visit our website at www.solaheviduty.com or
Contact Technical Services at (800) 377-4384 with any questions.
24 V, 5 A
2000 W
125
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
4
Power Supplies
SH15 & S3H15 Dimensions
SH20 & S3H20 Dimensions
8-inch Case Size (5” x 8” x 11”)
(18 lbs. / 8.2 kg. Maximum)
.94
23.80
SH20
11.00
(279.31
MAX
SLOT 1
SLOT 2
SLOT 3
SLOT 4
AC High
Neutral
Ground
1.2
8-32 UNC-2B
STD AIR FLOW
7.90 0.05
(200.66 1.27)
Input
Module
.05
1.27)
5.00
(127.03)
MAX
4.000 .020
(101.60 .50)
Side
J1
2.04 .05
(51.82 1.27)
.500 .050
(12.70 1.27)
3.49 10
(88.65 2.54)
4.94 10
(125.48 2.54)
6.750 .020
(171.45 .50)
.27
(6.86
6.39 10
(162.31 2.54)
.05
1.27)
.750 .050
(19.05 1.27)
AC Main Input
Bottom
Back
1.2
6.750 .020
(171.450 .50)
8-32 UNC-2B
Threaded
Insert, 4 Places
Max penetration:
0.150 (3.81)
.750 .050
(19.05 1.27)
1.067
(27.099
.050
1.270)
5.750 .020
(146.050 .508)
126
Visit our website at www.solaheviduty.com or
contact Technical Services at (800) 377-4384 with any questions.
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
4
Power Supplies
CVDC Power Supplies - 28 Series
Rackmount Regulated DC for industrial and telecommunication applications
Specifications
Parameter
Condition
Limit
Input
Input Voltage
100 to 130 VAC 60 Hz
Output
Actual variation is
approximately 1.4 %
voltage change for a 1%
frequency increase or
decrease
Source
Frequency Effect
Features
•
•
•
•
•
•
•
•
•
Line Regulation
±1%
Load Regulation
±5% (1/2 FL to FL)
Periodic
Deviations (Ripple)
1% RMS of Output
Ripple
Isolated output
Short circuit protected
Rack-mount
Highly reliable, convection cooled design
(no fan used or required)
Operating temperature at 50°C
MTBF greater than 300,000 hours
High efficiency
One year warranty
UL Recognized
Applications
• Process controls
• Drives
• Telecommunications and cellular applications
Telecommunications
Models
35 dbrn C (15 mv RMS)
Response Time
25 msec
General
Efficiency
Full Load
80% to 90%
Operating Ambient
Temperature
0°C to 50°C
Current Limit
250% Rated Current
Selection Table
Catalog Number
Output
Case
28-2233*
48 V @ 10 A
C-1
28-2234*
48 V @ 20 A
C-2
28-1024-1†
24 V @ 6 A
C-1
28-2126-1†
24 V @ 10 A
C-5
28-1203-2†
24 V @ 15 A
C-6
28-2127-1†
24 V @ 25 A
C-2
*Telecommunications models 115/230 V selectable and UL only.
†UL tested to CSA standards.
Dimensions (inches) Standard 19” Rackmounting
Case C
W
M
H
C-5
5 1/4
2 1/4
8 3/4
C-1
5 1/4
2 1/4
9 3/4
C-6
7
4
7 1/4
C-2
8 3/4
5 3/4
9 3/4
Visit our website at www.solaheviduty.com or
Contact Technical Services at (800) 377-4384 with any questions.
125
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
4
Power Supplies
Copper Line Series
Specifications
Parameter
Conditions
Limit
Input
105-130/210-260 VAC
(user selectable)
Input Voltage
Input Frequency
47-63 Hz
Input Protection
Ext. Slow- blow fuse
required
Output
Line Regulation
0.1% or 50 mV
Load Regulation
0.1% or 50 mV
Ripple
Full Rated Load
<1% RMS
Controls
Current Limit Adjust
Features
0-100%
10-100% Coarse Adjust
(may be mounted remotely).
Fine adjust fine tunes output
for no loads and full load
conditions.
Output Volt Adjust
• Full range adjustable output voltage and current
• Universal 120/240 VAC, 50/60 Hz input
• Single supply for multiple applications
• Parallel operation for increased power output
• UL Recognized
General
Applications
• Engineering bench supply
• Test equipment
• Manufacturing test applications
• Automotive product testing
Operating Temperature
Full Rated Load
0° to 50°C
Storage Temperature
Full Rated Load
-20° to 70°C
Efficiency
Full Rated Load
75%
Vibration
Designed to meet MILSTD-810D, Method 514.3,
Category Procedure 1.
Shock
Designed to meet MILSTD-810D, Method 516.3,
Category Procedure 3.
Dimensions
Selection Table
Maximum Current
Shipping
Weight
lbs (kg)
Power
Watts
Catalog
Number
Amps* @25
VDC (Adj. 2.525 VDC)
300
39-407
12 A
6A
23 (10.4)
600
39-408
24 A
12 A
30 (13.6)
1200
39-409
48 A
24 A
73 (33.1)
Amps* @50
VDC (Adj. 5-50
VDC)
* Current listed is the maximum at any voltage in that range.
Model
A
B
B1
C
D
E
F
F1
G
G1
39-407
10.4
-
7.7
6.8
3.8
5.3
-
3.5
-
3.6
39-408
11.4
-
7.7
6.8
3.8
5.3
-
3.5
-
4.6
39-409
14
11.1
-
10
6
8
8.3
-
3.5
Visit our website at www.solaheviduty.com or
Contact Technical Services at (800) 377-4384 with any questions.
127
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
4
Power Supplies
SCP-X Series
Selection Table
Catalog Number
Output
Current
Output
Voltage
Output
Power
SCP 100S24X-CM
3.8 A
24 Vdc
95 W
Mechanical Diagrams
9HAO
IND. CONT. EQ.
Also listed I.T.E.
Power Supply
E234790
Class 1 Zone 2
AEx nA IICT4
Ex nA IICT4 U
�� ��
SOLA
DEMK0 06 ATEX 05 21715U
EEX nA IIC T4 U
-40ºC ≤ Tam ≤ +60ºC
The SCP-X is a rugged power supply designed for use in
extreme environments. The metal case reduces costs by
eliminating separate enclosures and the quick change connectors simplify connectivity for distributed I/O devices on
industrial machinery. This model provides 24 Vdc output
with limited power to meet Class 2 requirements.
Features
• IP66/67 Versatile / NEMA 4X Rated
• Listed power supply for stand alone applications
• Can be mounted in any orientation without limitation
• Universal input
o
• High ambient temperature up to 60 C without derating
Electrical Connections
AC Input - EN175301-803 (formerly DIN 43650)
• DC OK Green LED
1. L1 (Line)
• Worldwide approvals
3
1
2. Ground
Accessory
3. L2 (Neutral)
Catalog
Number
Description
Approx. Ship
Weight lbs (kg)
SCP-DINBKT
Mounting bracket to secure
SCP-X to DIN Rail
1 (.45)
Related Products
2
DC Output - EN175301-803 (formerly DIN 43650)
1. V+
2
3
1
4
2. Ground*
• SDN Series
3. V-**
• SCP Series
4. V+
* Ground is isolated from V-.
** V- is isolated from ground. V- is a separately derived source so it is
permissible to bond to ground if required in the application.
76
Visit our website at www.solaheviduty.com or
contact Technical Services at (800) 377-4384 with any questions.
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
Power Supplies
4
SCP-X Specifications
Input
Nominal Voltage
Any voltage from 100 to 240 Vac Input
-AC Range
85-264 Vac Universal Input
-DC Range
100-353 Vdc
Nominal Current1
1.6A/0.7A
-Inrush current max.
Typ. <25A
Power Factor Correction2
0.95
Frequency
50/60/400 Hz
Output
Power Back Immunity
35V
Overvoltage Protection
25-25.5 Vdc, autorecovery
Nominal Voltage
Tolerance
24 Vdc
< +/-2% overall (combination line, load, time and temperature related changes).
- Line Regulation
< 0.5%
- Load Regulation
< 0.5%
- Time & Temp. Drift
Ripple
< 1%
< 50mVpp
3
Nominal Current
Holdup Time
3.8A
> 25ms (Full load, 100Vac Input @ Tamb=+25o) to 95% output voltage
General
Case
Min. Required Free Space
H x W x D (inches/mm)
IP66/67 versatile ingress protection; also meets UL50 Type 4X enclosure.
1 in. (25 mm) all sides but mounted base (permissible to mount in any orientation)
4.7 in. x 7 in. x 1.8 in.(119 mm x 178 mm x 46 mm)
Weight (lbs/kg)
2.6 lbs (1.16 kg)
EMC
Emissions
EN61000-6-3, EN61204-3, EN55022 Class B, EN61000-3-2, EN61000-3-3
Immunity
EN61000-6-2, EN61204-3, EN55024, IEC61000-4-2, IEC61000-4-3, IEC61000-4-4, IEC61000-4-5, IEC61000-4-6, IEC61000-4-8, IEC610004-11
Approvals
UL508, cULus; UL60950, cULus; UL60079-15 cRUus; IEC60950; CE (LVD 73/23 & 93/68/EEC). (EMC 89/336 & 93/68/EEC). EN61000-3-2,
EN50021 (Class 1, Division 2 Hazardous Location, EEX nA IIC T4 U up to 60°C Ambient.)4
Temperature
Storage: -40o to +85oC, Operation: -40o to +60oC full power with linear derating to half power from 60o to 70oC (Convection cooling, no forced
air required). Operation up to 100% load permissible with sideways or front side up mounting orientation.
Humidity
Up to 100% RH with condensation.
Altitude
0 to 3,000 meters (0 to 10,000 feet)
Vibration
Shock
0.15 gravity (g) peak, 5-500 Hz (swept sine); 5-500 Hz (random)
3g peak, 11 milliseconds half-sine pulse - IEC 68-2-27
Warranty
MTBF
5 years
>500,000 hours according to Telcoredia/Bellcore SR-332 Issue 1, (Vin 120Vac, Tamb=40oC)
General Protection/Safety
Protected against continuous short-circuit, continuous overload, continuous open circuit. Protection class 1 (IEC536), degree of protection
IP66/67 versatile (IEC 529). Safe low voltage: SELV (acc. IEC60950)
Status Indicators - Visual
DC OK LED
Installation
Fusing
-Input
Internally fused, fuses not replaceable
-Output
Inherently limited current to meet Class 2 requirements per UL1310
Mounting
Chassis mounted via built in mounting tabs. Removal and replacement of the unit shall be possible from front of panel.
Connections
Input: 3 pin IP67 molded plug (quick disconnect). Output: 4 pin IP67 molded receptacle (quick disconnect).
1 Input current ratings are specified with low input, line conditions, worst case efficiency values and power factor.
2 Power factor correction at 50/60 Hz only.
3 Ripple/noise is stated as typical AC values when measured with a 20 MHZ, bandwidth scope and 50 Ohm termination.
4 Additional installation requirements apply when used in hazardous locations (refer to user manual).
Visit our website at www.solaheviduty.com or
Contact Technical Services at (800) 377-4384 with any questions.
77
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project