Instruction Manual
Model 284-19
RF Splitter
January 2012, Rev. C
C
ROSS
T
ECHNOLOGIES, INC.
284 SPLITTER
LNB VOLTAGE POWER
RF MONITOR ON GND +DC ON
DC
J12
LNB FUSE F1
C
ROSS
T
ECHNOLOGIES, INC.
IN J9
OUT J1 OUT J2 OUT J3 OUT J4
OUT J8 OUT J7 OUT J6 OUT J5
Data, drawings, and other material contained herein are proprietary to Cross Technologies, Inc., but may be reproduced or duplicated without the prior permission of Cross Technologies, Inc. for purposes of operating the equipment. Printed in USA.
When ordering parts from Cross Technologies, Inc., be sure to include the equipment model number, equipment serial number, and a description of the part.
C ROSS T ECHNOLOGIES, INC.
6170 Shiloh Road
Alpharetta, Georgia 30005
(770) 886-8005
FAX (770) 886-7964
Toll Free 888-900-5588
WEB: www.crosstechnologies.com
E-MAIL: [email protected]
INSTRUCTION MANUAL
MODEL 284-19 RF Splitter
TABLE OF CONTENTS
Warranty
1.0 General
1.1 Equipment Description
1.2 Technical Characteristics
2.0 Installation
2.1 Mechanical
2.2 Rear Panel Input/Output Connectors
2.3 Front Panel Monitors and Indicators
2.4 Operation
2.5 Rack Mounting
3.0 Environmental Use Information
6
7
7
5
5
6
8
PAGE
2
3
3
4
WARRANTY - The following warranty applies to all Cross Technologies, Inc. products.
All Cross Technologies, Inc. products are warranted against defective materials and workmanship for a period of one year after shipment to customer. Cross Technologies,
Inc.’s obligation under this warranty is limited to repairing or, at Cross Technologies, Inc.’s option, replacing parts, subassemblies, or entire assemblies. Cross Technologies, Inc. shall not be liable for any special, indirect, or consequential damages. This warranty does not cover parts or equipment which have been subject to misuse, negligence, or accident by the customer during use. All shipping costs for warranty repairs will be prepaid by the customer. There are not other warranties, express or implied, except as stated herein.
284-19 Manual, Rev C
C ROSS T ECHNOLOGIES, INC.
6170 Shiloh Road
Alpharetta, Georgia 30005
(770) 886-8005
FAX (770) 886-7964
Toll Free 888-900-5588
WEB: www.crosstechnologies.com
E-MAIL: [email protected]
Page 2 01/18/12
MODEL 284-19 RF Splitter
1.0 General
1.1 Equipment Description - The Model 284-19 is a nine way, 0.95 - 2.1 GHz, 0 dB gain splitter in a 4.7”W x
1.75”H x 6.5”D bench top chassis (or mounted on an optional 1 Rack Unit panel) with a 115 VAC wall power supply. The splitter provides fused DC power insertion on the RF input connector center pin, surge protection, and excellent RF characteristics. The splitter has a monitor connector on the front panel and eight outputs on the back panel. The 115 VAC wall power supply provides a +18 VDC voltage for internal amplifiers and for DC to power an external amplifier (often Low Noise Block converters or LNBs) through a DC power inserter. The
LNB power line is separately fused. A surge suppressor on the splitter input protects against high voltage transients. All splitter outputs are AC coupled so no DC appears on their center conductors. On the front panel, a green LED indicates the presence of +18 VDC at the LNB power supply output and DC voltage test points allow monitoring this voltage with a voltmeter. Presence of power from the +18 VDC wall power supply is shown by the green AC Power LED. Up to three 284’s can be mounted on an optional 1 3/4”x 19” rack mount panel (option R1, R2, or R3).
C
ROSS
T
ECHNOLOGIES, INC.
284 SPLITTER
LNB VOLTAGE POWER
RF MONITOR ON ON GND +DC
FRONT
DC
J12
LNB FUSE F1
C
ROSS
T
ECHNOLOGIES, INC.
IN J9
OUT J1 OUT J2 OUT J3 OUT J4
OUT J8 OUT J7 OUT J6 OUT J5
REAR
FIGURE 1.1 MODEL 284-19 Front and Rear Panels
C
ROSS
T
ECHNOLOGIES, INC.
284 SPLITTER
LNB VOLTAGE POWER
RF MONITOR ON GND +DC ON
C
ROSS
T
ECHNOLOGIES, INC.
284 SPLITTER
LNB VOLTAGE POWER
RF MONITOR ON GND +DC ON
C
ROSS
T
ECHNOLOGIES, INC.
284 SPLITTER
LNB VOLTAGE POWER
RF MONITOR ON GND +DC ON
FIGURE 1.2 Three 284s Mounted on Optional -R3 Rack Panel
1 - 2
GHz
IN
SURGE
SUP-
PRESOR
DC
INS
FUSE
AMP
9 WAY
SPLIT
1 - 2 GHz OUT
OUT 1
OUT 2
:OUT3
OUT 8
MON
LNB PWR LED
LNB PWR TP
284-19 Manual, Rev C
FIGURE 1.3 Model 284-19 RF Splitter Block Diagram
Page 3 01/18/12
1.2 Technical Characteristics
TABLE 1.1 284-15 RF SPLITTER SPECIFICATIONS
Characteristics
Input Characteristics
Input Impedance/RL
Specifications*
Input Level
75 Ω /10dB, min, 0.95-2.05 GHz
12dB min.,14dB typical, 0.95-1.75 GHz
-20 dBm total maximum
Output Characteristics
Impedance/RL 75 Ω /10dB, min, 0.95-2.05 GHz
12dB min., 14 dB, typical 0.95-1.75 GHz
In-Band Characteristics
Gain
Frequency Response
Port to Port Isolation
Indicators
Power
LNB DC Voltage
+0 dB ± 1.0 dB
± 1.0 dB, 0.95 - 2.05 GHz; ± 0.5 dB, any 20 MHz increment
> 18 dB, min., 20 dB typical
Green LEDs indicate DC voltage prior to diode OR
Green LED indicates LNB power insertion on splitter input (J9)
Other
LNB DC Voltage
Output LNB Current
Surge Suppressor
RF Connectors
AC Power
Size, Bench Top
Size, Rack Mount (-R)
Options
-R1, -R2, or -R3
-C
-P2
-B
-D
-W9
Models
284-15
284-19
18 ±2 VDC
300 ma, max.
SiDACTOR
Type F (female)
115 VAC, 60 Hz, 10W max., wall power supply
4.7”W x 1.75”H x 6.5”D
19 inch standard chassis, 1.75” high X 7.0” deep
Rack Mounting (1RU)
No Wall Mount Power Supply (use Model 2000-02 Power Supply)
100-240 ±10% Vac Wall Mount Power Supply
75 Ω BNC RF Connectors
50 Ω BNC RF Connectors
10MHz pass through (J9 to J8)
One 5-way splitter
One 9-way splitter
*+10˚C to +40˚C; Specifications subject to change without notice.
284-19 Manual, Rev C Page 4 01/18/12
2.0 Installation
2.1 Mechanical - The 284-19 consists of one RF printed circuit board (PCB) housed in a 4.7”W x 1.75”H x
6.5”D bench top chassis. A 115 VAC, 60Hz wall power supply provides +18VDC power for the internal and external amplifiers and LEDs. RF connectors are type F, female. The 284-19 can also be secured to a rack using the four holes on the optional 1 RU chassis front panel. Figure 2.1 shows how the 284-19 is assembled. J11 connects DC Power to the fuses as shown and J12 connects the DC voltage from the power supply to the PCB as shown.
FIGURE 2.1 284-19 Mechanical Assembly
WALL POWER
SUPPLY
PIN 1, +18VDC
PIN 2, GROUND
POWER SUPPLY J12
2 1
1
2
FUSE
J11
PIN 1, LNB SIDE
PIN 2, +18VDC SIDE
284-19 Manual, Rev C Page 5 01/18/12
2.2 Rear Panel Input/Output Connectors
The input and output connectors on the rear panel are shown in Figure 2.2.
CAUTION! IF A FUSE IS INSTALLED IN THE LNB FUSE F1 HOLDER, +18 VDC WILL APPEAR ON
THE CENTER PIN OF THE SPLITTER INPUT CONNECTOR.
J12 - DC INPUT
+18VDC from wall power supply
LNB FUSE F1
F1 - LNB FUSE
1 Amp, Fast Blo, 1/4” Fuse
C
ROSS
T
ECHNOLOGIES, INC.
DC
J12
IN J9
OUT J1
OUT J8
OUT J2 OUT J3 OUT J4
OUT J7 OUT J6 OUT J5
J9 - SPLITTER INPUT
Type F, 75 Ω
CAUTION! +18 VDC ON
CENTER PIN WHEN FUSE F1
INSTALLED
10MHZ
Pass Through
(Option W9)
J1 to J8 - SPLITTER OUTPUTS
Type F, 75 Ω
Terminate when not used
FIGURE 2.2 284-19 Rear Panel
2.3 Front Panel Monitors and Indicators
Figure 2.3 shows the front panel monitors and indicators.
J10 - SPLITTER MONITOR
Type F, 75 Ω
Terminate when not used
TP2 - GROUND
Ground Test Point
TP1 - LNB VOLTAGE
Test Point which allows monitoring of the 18 ± 2 VDC present on J9.
C
ROSS
T
ECHNOLOGIES, INC.
RF MONITOR
284 SPLITTER
LNB VOLTAGE
ON GND +DC
POWER
ON
DS1 - LNB VOLTAGE LED
Green LED lights when LNB voltage is present on splitter input, J9.
DS2 - POWER LED
Green LED lights when power is applied to unit
FIGURE 2.3 284-19 Front Panel
284-19 Manual, Rev C Page 6 01/18/12
2.4 Operation
1.) Connect RF cables to the 284-19 (See Sections 2.2 and 2.3).
2.) IF DC VOLTAGE IS REQUIRED ON THE SPLITTER RF INPUT CENTER
CONDUCTOR, install a 1/4”, 1 amp fast blo fuse in LNB FUSE F1 holder.
CAUTION! IF A FUSE IS INSTALLED IN THE LNB FUSE F1 HOLDER, +18 VDC WILL APPEAR ON
THE CENTER PIN OF THE SPLITTER INPUT CONNECTOR.
3.) Connect the wall power supply to the DC J12 connector on the rear panel of the 284-19 and then to a 115 VAC, 60Hz power outlet, and observe that the POWER LED is lit on the front panel.
4.) Monitor the RF signal on the front panel monitor and DC voltage to the external amplifiers (Front panel Green LNB VOLTAGE LED should be lit if a LNB fuse is installed in the rear panel fuse holder) to insure proper signal and voltage.
NOTE: FOR OPTIMUM PERFORMANCE, THE MONITOR PORT AND SPLITTER OUTPUT PORTS
SHOULD BE TERMINATED WITH 75 Ω TYPE F TERMINATIONS WHEN NOT USED.
2.5 Rack Mounting - The 284-19 is packaged in an aluminum extrusion. The -R option is mounted on a 1
3/4” x 19” rack panel that can be mounted to a rack using the four holes at the ends. To mount a 284-19 unit to a rack panel, remove the four screws attaching the front panel to the extrusion, and then (using the same screws) reattach the front panel to the front of the rack panel with the extrusion (containing the PCB) on the other side of the rack panel (see Figure 2.5).
EXTRUSION
FRONT PANEL
C
ROSS
T
ECHNOLOGIES, INC.
284 SPLITTER
LNB VOLTAGE POWER
RF MONITOR ON GND +DC ON
RACK MOUNT PANEL (FOR -R MODELS ONLY)
FRONT SCREWS (4EA)
FIGURE 2.5 Rack Mounting The 284-19
284-19 Manual, Rev C Page 7 01/18/12
3.0 Environmental Use Information
A. Rack-Mounting - To mount this equipment in a rack, please refer to the installation instructions located in the user manual furnished by the manufacturer of your equipment rack. (See figure 2.5)
B. Mechanical Loading - Mounting of equipment in a rack should be such that a hazardous condition does not exist due to uneven weight distribution.
C. Elevated Operating Ambient Temperature - If installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack may be greater than room ambient temperature.
Therefore, consideration should be given to Tmra.
D. Reduced Air Flow - Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised. Additional space between unit may be required.
E. Circuit Overloading - Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of circuits could have on over current protection and supply wiring.
Appropriate consideration of equipment name plate rating should be used, when addressing this concern.
F. Reliable Earthing - Reliable earthing of rack-mounted equipment should be maintained.
Particular attention should be given to supply connections other than direct connection to the
Branch (use of power strips).
G. Top Cover - There are no serviceable parts inside the product so, the Top Cover should not be removed.
If the Top Cover is removed the ground strap and associated screw MUST BE REINSTALLED prior to Top Cover screw replacement. FAILURE TO DO this may cause INGRESS and/or EGRESS emission problems.
284-19 Manual, Rev C Page 8 01/18/12
C ROSS T ECHNOLOGIES, INC.
6170 Shiloh Road
Alpharetta, Georgia 30005
(770) 886-8005
FAX (770) 886-7964
Toll Free 888-900-5588
WEB: www.crosstechnologies.com
E-MAIL: [email protected]
Printed in USA
284-19 Manual, Rev C Page 9 01/18/12