Altronix HUBSAT4D Installation manual

Add to my manuals
8 Pages

advertisement

Altronix HUBSAT4D Installation manual | Manualzz

Video • Data • Power

Passive UTP Transceiver Hub with Integral Camera Power

Installation Guide

Models Include:

HubSat4D

- Four (4) Channel Passive UTP Transceiver Hub with Integral Camera Power

HubSat42D

- Four (4) Channel Passive UTP Transceiver includes four (4) HubWayAv

Video Balun/Combiners

HubSat43D

- Four (4) Channel Passive UTP Transceiver includes four (4) HubWayDv

Video Balun/Combiners

More than just power.

TM Rev. 112408

Overview:

Altronix HubSat4D Passive UTP Transceiver Hub with Integral Camera Power transmits UTP video, RS422/RS485 data and power over a single CAT-5 or higher structured cable. Unit provides 4 camera channels in a wall mount enclosure. Video transmission range is up to 750 ft. max. per channel. Units are compatible with AC and/or DC fixed or PTZ cameras when utilizing Altronix HubWayAv, HubWayAv2, HubWayDv or HubWayDvi Video Balun/Combiners. In addition, the unit features individually selectable 24VAC or 28VAC PTC protected outputs with surge suppression. Optionally, the HubSat4D can be used as an accessory module to transmit video from up to 4 cameras over a single CAT-5 or higher structured cables back to the HubWay, HubWayLD or HubWayLDH Passive and Active UTP Transceiver Hubs. In addition, the HubSat4D provides power to these cameras locally to eliminate the possibility of voltage drop associated with long cable runs.

Specifica tions:

Agency Listings:

• UL Listed for Commercial CCTV Equipment (UL 2044).

CUL Listed - CSA Standard C22.2 No.1-04, Audio,

Video and Similar Equipment.

Input:

• 115VAC 60Hz, 1.25 amp.

• Primary in-line fuse is rated @ 3.5A/250V.

Video:

• Four (4) channels of quality video over twisted pair

up to a distance of 750 ft. per channel.

• Four (4) 75 ohm video outputs.

Data:

• RS422/RS485 data input.

Power:

• Individually selectable 24VAC or 28VAC power

outputs with OFF position.

Additional Models:

Power (cont’d):

• Unit provides up to 1 amp max. per channel not to

exceed a total of 4 amp maximum current.

• PTC protected outputs are rated @ 1 amp per channel.

• Surge suppression.

Visual Indicators:

• Four (4) power LED indicators.

Enclosure Dimensions (H x W x D approx.):

8.5” x 7.5” x 3.5” (215.9mm x 190.5mm x 88.9mm).

Optional Accessories:

• Video Balun/Combiners:

- HubWayAv - for use with 24VAC cameras.

- HubWayAv2 - for use with 24VAC cameras.

- HubWayDv - for use with 12VDC cameras.

- HubWayDvi - for use with non-isolated 12VDC cameras.

HubSat42D

• HubSat4D with four (4) HubWayAv

Video Balun/Combiners for 24VAC Cameras.

HubSat43D

• HubSat4D with four (4) HubWayDv

Video Balun/Combiners for 12VDC Cameras.

WARNING: To reduce the risk of fire or electric shock, do not expose the unit to rain or moisture.

This installation should be made by qualified service personnel and should conform to all local codes.

Installation Instructions:

HubSat4D Passive UTP Transceiver Hub with Integral Camera Power.

1. Mount unit in desired location. Mark and predrill holes in the wall to line up with the top two keyholes in the enclosure. Install two upper fasteners and screws in the wall with the screw heads protruding. Place the enclosure’s upper keyholes over the two upper screws; level and secure. Mark the position of the lower two holes. Remove the enclosure. Drill the lower holes and install the two fasteners. Place the enclosure’s upper keyholes over the two upper screws. Install the two lower screws and make sure to tighten all screws (Enclosure Dimensions, pg. 8).

Secure green wire lead to earth ground.

2. Set illuminated master power disconnect circuit breaker to the [OFF] position (Fig. 5a, pg. 6).

3. Connect 115VAC 60Hz to the black and white flying leads of open frame transformer. Secure ground wire (Green) to earth ground (Fig. 5, pg. 6).

4. S elect 24VAC or 28VAC power output for each of the Channels 1-4 on HubSat (Fig. 5, pg. 6) with the corresponding output voltage switches. Select OFF position when servicing or installing individual cameras

(Fig. 1d, pg. 4).

5. Connect the BNC video outputs marked [Video 1-4] on HubSat to the corresponding video inputs on the head end equipment (DVR) (Fig. 1a, pg. 4).

6. Connect terminals marked [+ DATA --- ] on HubSat (polarity must be observed) to the RS422/RS485 output of the head end equipment (DVR) (Fig. 1f, pg. 4). When using fixed cameras disregard this step.

7. Plug the RJ45 connector at one end of the CAT-5 or higher structured cable into the RJ45 jack marked [PVD1] on HubSat (Fig. 1i, pg. 4). Plug the RJ45 connector at the opposite end of the CAT-5 or higher structured cable into the RJ45 jack of the Video Balun/Combiner to be installed at camera 1.

- 2 - HubSat4D

• For 24VAC cameras use Altronix model HubWayAv/HubWayAv2 Video Balun/Combiner (Figs. 2a, 2b, 2e, pg. 5-6).

• For 12VDC cameras use Altronix model HubWayDv Video Balun/Combiner (Figs. 2c, 2d, pg. 6).

• For non-isolated 12VDC cameras use Altronix model HubWayDvi Video Balun/Combiner (Figs. 2c, 2d, pg. 5).

The total cable distance must not exceed 750 ft. for video transmission between the HubSat and each camera.

Repeat this step for all other camera channels [PVD2-4].

8. Set illuminated master power disconnect circuit breaker to the RESET (ON) position (Fig. 5a, pg. 6) power

LEDs (Green) of the HubSat will illuminate when AC power is present (Fig. 1e, pg. 4) and HubWayAv, HubWayDv or HubWayDvi Video Balun/Combiner LEDs will illuminate indicating power is present (Fig. 2b, 2d, pg. 6).

9. Measure the output voltage at each Video Balun/Combiner (Figs. 2b, 2d, pg. 5) before making connections to each camera to ensure proper operation and avoid possible damage.

10. Set illuminated master power disconnect circuit breaker to the [OFF] position (Fig. 5a, pg. 6).

11. Connect power outputs of HubWayAv, HubWayAv2, HubWayDv or HubWayDvi Video Balun/Combiners to power inputs of cameras (Figs. 2a-2e, pg. 5-6). Polarity must be observed.

• HubWayAv/HubWayAv2 - Terminals marked [AC POWER] (Figs. 2a, 2b, 2e, pg. 5-6).

• HubWayDv/HubWayDvi - Terminals marked [– 12VDC +] (Figs. 2c, 2d, pg. 5).

12. Connect the terminals marked [+ DATA -- ] of HubWayAv, HubWayAv2, HubWayDv or HubWayDvi Video

Balun/Combiners to data input terminals of cameras for PTZ control (Figs. 2b-2d, pg. 6). Polarity must be observed.

When using fixed cameras disregard this step.

13. Connect the BNC connector of HubWayAv, HubWayAv2, HubWayDv or HubWayDvi Video Balun/Combiners to the BNC video outputs of cameras (Figs. 2b-2d, pg. 5).

14. Set illuminated master power disconnect circuit breaker to the RESET (ON) position (Fig. 5a, pg. 6).

15. The power LEDs (Green) of the HubSat will illuminate when AC power is present (Fig. 1e, pg. 4).

Note: If any of the power LEDs are not illuminated the cause may be due to the following: a. AC mains fail.

b. Illuminated master power disconnect circuit breaker is tripped.

c. Primary in-line fuse is blown.

Note: Replace fuse with same type and rating:

Primary in-line fuse is rated @ 3.5A/250V (Fig. 5b, pg. 6).

Primary

In-line Fuse d. An individual power output voltage switch is set to the [OFF] position (Fig. 1d, pg. 4).

e. A PTC is tripped due to a short circuit or overload condition for one or more channels/power outputs.

To reset the PTC:

1. Set the voltage output selector switch for that corresponding channel to the OFF position. Switch must remain in the OFF position for approximately 2 minutes in order for the PTC to reset (Fig. 1d, pg. 4).

2. Eliminate the trouble condition (short circuit or overload).

3. Set the voltage output selector switch for either 24VAC or 28VAC (Fig. 1d, pg. 4).

HubSat4D for use as a Remote Accessory Module with HubWay/HubWayLD/HubWayLDH UTP Transceiver Hubs.

After completing steps 1-4 of Installation Instructions HubSat4D Passive UTP Transceiver Hub with Integral Camera

Power proceed with the following.

1. For fixed cameras run a single CAT-5 cable between HubSat and HubWay, HubWayLD or HubWayLDH to allow video transmission of up to four (4) cameras. For PTZs run two (2) CAT-5 cables between HubSat and

HubWay, HubWayLD or HubWayLDH (Fig. 7, pg. 7).

a. Connect one (1) of the CAT-5 cables to the RJ45 jack marked [Video 1-4] on HubSat. Connect the opposite end of this CAT-5 cable into the RJ45 jack marked [CH 1-4] of HubWay, HubWayLD or

HubWayLDH (Fig. 7, pg. 7).

b. For data (PTZ) connect the second CAT-5 cable to the RJ45 jack marked [Data 1-4] on HubSat. Connect the opposite end of this CAT-5 cable into any unused RJ45 jack marked [1-16] of HubWay, HubWayLD or

HubWayLDH (Fig. 7, pg. 7).

Note: Data inputs of HubWay, HubWayLD or HubWayLDH units must be wired in parallel for proper operation.

When using fixed cameras disregard this step.

2. Plug the RJ45 connector at one end of the CAT-5 or higher structured cable into the RJ45 jack marked [PVD1] on HubSat (Fig. 1i, pg. 4). Plug the RJ45 connector at the opposite end of the CAT-5 or higher structured cable into the RJ45 jack of the Video Balun/Combiner to be installed at camera 1.

• For 24VAC cameras use Altronix model HubWayAv/HubWayAv2 Video Balun/Combiner (Figs. 2a, 2b, 2e, pg. 5-6).

• For 12VDC cameras use Altronix model HubWayDv Video Balun/Combiner (Figs. 2c, 2d, pg. 5).

• For non-isolated 12VDC cameras use Altronix model HubWayDvi Video Balun/Combiner (Figs. 2c, 2d, pg. 5).

The total cable distance must not exceed 750 ft. for video transmission between the HubSat8D and each camera.

Repeat this step for all other camera channels [PVD2-4].

HubSat4D - 3 -

3. Set illuminated master power disconnect circuit breaker to the RESET (ON) position (Fig. 5a, pg. 6) power

LEDs (Green) of the HubSat will illuminate when AC power is present (Fig. 1e, pg. 4) and HubWayAv, HubWayDv or HubWayDvi Video Balun/Combiner LEDs will illuminate indicating power is present (Fig. 2b, 2d, pg. 6).

4. Measure the output voltage at each Video Balun/Combiner (Figs. 2b, 2d, pg. 6) before making connections to each camera to insure proper operation and avoid possible damage.

5. Set illuminated master power disconnect circuit breaker to the (OFF) position (Fig. 5a, pg. 6).

6. Connect power outputs of HubWayAv, HubWayAv2, HubWayDv or HubWayDvi Video Balun/Combiners to power inputs of cameras (Figs. 2a-2e, pg. 5-6). Polarity must be observed.

• HubWayAv/HubWayAv2 - Terminals marked [AC POWER] (Figs. 2a, 2b, 2e, pg. 5-6).

• HubWayDv/HubWayDvi - Terminals marked [– 12VDC +] (Figs. 2c, 2d, pg. 5).

7. Connect the terminals marked [+ DATA -- ] of HubWayAv, HubWayAv2, HubWayDv or HubWayDvi Video

Balun/Combiners to data input terminals of cameras for PTZ control (Figs. 2b-2d, pg. 5). Polarity must be observed.

When using fixed cameras disregard this step.

8. Connect the BNC connector of HubWayAv, HubWayAv2, HubWayDv or HubWayDvi Video Balun/Combiners to the BNC video outputs of cameras (Figs. 2a-2e, pg. 5-6).

9. Set illuminated master power disconnect circuit breaker to the RESET (ON) position (Fig. 5a, pg. 6).

10. The power LEDs (Green) of the HubSat will illuminate when AC power is present (Fig. 1e, pg. 4).

Note: If any of the power LEDs are not illuminated the cause may be due to the following: a. AC mains fail.

b. Illuminated master power disconnect circuit breaker is tripped.

Primary c. One or both primary in-line fuse(s) are blown.

Note: Replace fuse with same type and rating:

In-line Fuse

Primary in-line fuses are rated @ 3.5A/250V (Fig. 5b, pg. 6).

d. An individual power output voltage switch is set to the OFF position (Fig. 1d, pg. 4).

e. A PTC is tripped due to a short circuit or overload condition for one or more channels/power outputs.

To reset the PTC:

Fig. 1 - HubSat Circuit Board

1c 1c

1b 1d

28VAC AUX1 AUX2 28VAC 28VAC AUX3 AUX4 28VAC

24VAC

VIDEO1

24VAC 24VAC

VIDEO2 VIDEO3

24VAC

VIDEO4

1e

1a

1f

1i

PVD1 PVD2 DATA 1-4

1h

1a - BNC Connector: Video in from remote camera video out to DVR.

1b - Output PTCs: Protects each output.

1c - Power Terminals: 24VAC/28VAC power outputs.

1d - Output Voltage Switches: Selects 24VAC/28VAC/

OFF for each output.

1e - LED(s) 1-4: Power output indicators.

1f - Data: RS422/RS485 input from head end equipment

(DVR) for PTZ control.

- 4 -

VIDEO 1-4 PVD3 PVD4

1g

1g - Channels 1-4: Single CAT-5 or higher structured cable out to HubWay, HubWayLD or HubWayLDH enables transmission of up to four (4) video signals.

Pin out configuration (Fig. 4, pg. 6).

1h - Data: CAT-5 or higher structured cable to data port on HubWay, HubWayLD or HubWayLDH or head end equipment (DVR).

1i - Channels 1-4: CAT-5 or higher structured cable to cameras. Pin out configuration (Fig. 3, pg. 6).

HubSat4D

1. Set the voltage output selector switch for that corresponding channel to the OFF position. Switch must remain in the OFF position for approximately 2 minutes in order for the PTC to reset (Fig. 1d, pg. 4).

2. Eliminate the trouble condition (short circuit or overload).

3. Set the voltage output selector switch for either 24VAC or 28VAC (Fig. 1d, pg. 4).

Alternate 24VAC fixed camera hookup (Fig. 6a, pg. 7).

After completing steps 1-5 of Installation Instructions Remote Accessory Module for use with HubWay, HubWayLD or

HubWayLDH UTP Transceiver Hubs proceed with the following.

1. Set illuminated master power disconnect circuit breaker to the (OFF) position (Fig. 5a, pg. 6).

2. Connect one end of the coaxial cable to the BNC connector marked [Video1] on HubSat (Fig. 1a, pg. 4).

Connect the opposite end of the coaxial cable to the BNC video output of camera 1 (Fig. 7a, pg. 7).

3. Set illuminated master power disconnect circuit breaker to the RESET (ON) position (Fig. 5a, pg. 6) measure the output voltage at terminal pair marked [AUX1] on HubSat to insure proper operation and avoid possible

(Fig. 1b, pg. 4).

4. Connect the power output terminal pair marked [AUX1] on HubSat to the power inputs of camera 1

(Fig. 1c, pg. 4). Repeat steps 1-3 for each additional camera [AUX2-4].

HubWayAv, HubWayAv2, HubWayDv, and HubWayDvi Video Balun/Combiners:

Altronix

Model Number

Input Voltage from HubWay

Unit Output Voltage to Camera Camera Type Power LED

HubWayAv *24VAC/28VAC *24VAC/28VAC

HubWayAv2 *24VAC/28VAC *24VAC/28VAC

HubWayDv *24VAC/28VAC 12VDC

*24VAC/28VAC

*24VAC/28VAC

12VDC cameras

Green

N/A

Red

HubWayDvi *24VAC/28VAC 12VDC electronically isolated 12VDC cameras without isolation Red

*Based on camera load and structured cable length.

Fig. 2 - HubWayAv and HubWayDv/Dvi Video Balun/Combiners

Fig. 2a

VIDEO

Fig. 2c

VIDEO

HubWayAv

VIDEO BALUN/COMBINER

AC

CAT5 + DATA-- POWER

HubWayDv

VIDEO BALUN/COMBINER

CAT5 + DATA-- -- 12VDC+

* Also Available as:

HubWayDvi

Video Balun/

Combiner

for non-isolated

12VDC cameras

RJ45 Jack Wire Connectors RJ45 Jack Wire Connectors

Fig. 2b

Green

Power LED

To BNC

Connector of Camera

Structured

Cable from

HubSat4D

+ --

Data to

Camera

AC Power to Camera

HubWayAv passes AC voltage from pins

4, 5, 7, 8 to terminals marked [AC Power]

(Fig. 3, pg. 6).

Fig. 2e

HubWayAv2

Cat5 back to

HubWay or

HubSat

Fig. 2d

Red

Power LED

To BNC

Connector of Camera

Structured

Cable from

HubSat4D

+ --

Data to

Camera

+

--

12VDC Power to Camera

HubWayDv/HubWayDvi converts AC voltage to DC voltage from pins 4, 5, 7, 8 to terminals marked

[-- 12VDC +] (Fig. 3, pg. 6).

Power to Camera

Data to Camera

HubWayAv2 passes AC voltage from pins

4, 5, 7, 8 to terminals marked [AC Power]

(Fig. 3, pg. 6).

Video from Camera

HubSat4D - 5 -

Fig. 3 - CAT-5 Structured Cable Wiring Color

Codes and PIN Configurations PVD1-4 on HubSat4D and

Video Balun/Combiner

1 - White/Orange [VIDEO +]

2 - Orange [VIDEO -- ]

3 - White/Green [DATA +]

4 - Blue [AC 1]

5 - White/Blue [AC 2]

6 - Green [DATA -- ]

7 - White/Brown [AC 2]

8 - Brown [AC 1]

Fig. 4 - CAT-5 Structured Cable Wiring Color Codes for Video 1-4 Port on HubSat4D board

1 - White/Orange [VIDEO OUT 4]

2 - Orange [VIDEO OUT 4]

3 - White/Green [VIDEO OUT 3]

4 - Blue [VIDEO OUT 2]

5 - White/Blue [VIDEO OUT 2]

6 - Green [VIDEO OUT 3]

7 - White/Brown [VIDEO OUT 1]

8 - Brown [VIDEO OUT 1]

Fig. 5

Illuminated master power disconnect circuit breaker:

• OFF position: circuit breaker tripped –

Switch not illuminated.

• RESET (ON) position –

Switch illuminated.

Fig. 5a

(ON)

28VAC AUX1 AUX2 28VAC 28VAC AUX3 AUX4 28VAC

0 (Br)

24VAC 24VAC 24VAC 24VAC

VIDEO1 VIDEO2 VIDEO3

24(YL)

VIDEO4

Fig. 5b

Primary In-line fuse:

Rated @ 3.5A/250V

115VAC

Input

60 Hz.

PVD1 PVD2

Primary

In-line

Fuse

DATA 1-4 VIDEO 1-4 PVD3 non power-limited

PVD4

Black

Lead

White

Lead non power- limited

XFMR

Green Lead

(Ground)

- 6 - HubSat4D

Fig. 6

Typical Application Drawing

HubSat4D Passive UTP Transceiver Hub with Integral Camera Power:

Head End Equipment (DVR)

Monitor

RS485

Data

Data

Video

Power

12VDC PTZ

Camera

CAT-5

HubWayDv/Dvi

Video Balun

Combiner

Video

Power

CAT-5

HubWayDv/Dvi

Video Balun

Combiner

12VDC Fixed

Camera

BNC

CAT-5

HubWayAv

Video Balun

Combiner

Data

Video

Power

24VAC PTZ

Camera

115VAC Input,

60Hz

24VAC/28VAC

Camera Power

Provided by HubSat4D

CAT-5

HubWayAv

Video Balun

Combiner

Video

Power

24VAC Fixed

Camera

Fig. 7

Typical Application Drawing

HubSat4D Remote Accessory Module with HubWay UTP Transceiver Hubs:

Head End Equipment (DVR)

RS485

Monitor

Video

Data

Rear

8 7 6 5 4 3 2 1

PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN AC POWER

1 2 3 4 CH 1-4 5 6 7 8 CH 5-8

28VAC

OFF

24VAC

Front

Data

Video

Power

CAT-5

Data

(CAT-5)

Four (4) Video signals on a single CAT-5

CAT-5

Data

Video

Power

12VDC

PTZ

Camera

HubWayDv/Dvi

Video Balun

Combiner

CAT-5

Video

Power

12VDC

Fixed

Camera

HubWayDv/Dvi

Video Balun

Combiner

Power

Video (Coax)

Four (4) Video signals on a single CAT-5

Power

Video (Coax)

24VAC/28VAC

Camera Power

Provided by HubSat4D

115VAC

Input, 60Hz

HubWayAv

Video Balun

Combiner

24VAC

PTZ

Camera

CAT-5

Video

Power

HubWayAv

Video Balun

Combiner

24VAC

Fixed

Camera

24VAC

Fixed

Camera

24VAC

Fixed

Camera

Power

Video (Coax)

Power

Video (Coax)

24VAC/28VAC

Camera Power

Provided by HubSat4D

24VAC

Fixed

Camera

115VAC

Input, 60Hz

24VAC

Fixed

Camera

Fig. 7a - Alternate 24VAC fixed camera hookup.

HubSat4D - 7 -

The lightning flash with arrow head symbol within an equilateral triangle is intended to alert the user to the presence of an insulated DANGEROUS VOLTAGE within the product’s enclosure that may be of sufficient magnitude to constitute an electric shock.

The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance.

CAUTION: To reduce the risk of electric shock do not open enclosure. There are no user serviceable parts inside. Refer servicing to qualified service personnel.

Enclosure Dimensions

(H x W x D approximate)

:

8.5” x 7.5” x 3.5” (215.9mm x 190.5mm x 88.9mm)

7.25”

(184.15mm)

3.625”

(184.15mm)

1.25”

(31.75mm)

3.5”

(88.9mm)

2”

(50.8mm)

1.25”

(31.75mm)

0.6”

(15.24mm)

1.125”

(28.575mm)

6.05”

(153.67mm)

0.6”

(15.24mm)

1.125”

(28.575mm)

2”

(50.8mm)

8.125”

(206.375mm)

1”

(25.4mm)

0.6”

(15.24mm)

6.05”

(153.67mm)

1”

(25.4mm)

5.25”

(133.35mm)

Altronix is not responsible for any typographical errors.

140 58th Street, Brooklyn, New York 11220 USA, 718-567-8181, fax: 718-567-9056 website: www.altronix.com, e-mail: [email protected], Lifetime Warranty, Made in U.S.A.

IIHubSat4D D27O

- 8 -

1”

(25.4mm)

0.6”

(15.24mm)

3.5”

(88.9mm)

1”

(25.4mm)

1”

(25.4mm)

1.25”

(31.75mm)

MEMBER

HubSat4D

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement