Instruction Manual commercial gas water heaters MODELS BTP 139(A) Thru 370(A) SERIES 104/105 INSTALLATION - OPERATION - SERVICE - MAINTENANCE - LIMITED WARRANTY 500 Tennessee Waltz Parkway Ashland City, TN 37015 Low Lead Content WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or death. Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. WHAT TO DO IF YOU SMELL GAS: • Do not try to light any appliance. • Do not touch any electrical switch; not use any phone in your building. do • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. • If you cannot reach your gas supplier, call the fire department. Installation and service must be performed by a qualified installer, service agency or the gas supplier. Thank you for buying this energy efficient water heater. We appreciate your confidence in our products. Read and understand this instruction manual and the safety messages herein before installing, operating or servicing this water heater. Failure to follow these instructions and safety messages could result in death or serious injury. This manual must remain with the water heater. place these instructions adjacent to heater and notify owner to keep for future reference. PRINTED 1212 194186-002 Table Of Contents Safe Installation, Use and Service���������������������������������������� 3 Air From Other Indoor Spaces�������������������������������������������������������� 18 Approvals������������������������������������������������������������������������������������������ 3 Vent Connection������������������������������������������������������������������������������ 19 General Safety Information�������������������������������������������������4-5 Water Heater Installation�������������������������������������������������19-22 Precautions��������������������������������������������������������������������������������������� 5 Water Line Connections������������������������������������������������������������������ 19 Grounding Instructions���������������������������������������������������������������������� 5 T&P Valve Discharge Pipe�������������������������������������������������������������� 19 Hydrogen Gas Flammable���������������������������������������������������������������� 5 Installation Diagrams - Top Inlet/Outlet Usage������������������������������� 20 Introduction����������������������������������������������������������������������������������� 6 Burner Installation��������������������������������������������������������������������������� 20 Abbreviations Used��������������������������������������������������������������������������� 6 Heater Wiring���������������������������������������������������������������������������������� 21 Qualifications������������������������������������������������������������������������������������ 6 Gas Piping��������������������������������������������������������������������������������������� 22 Start Up Requirements��������������������������������������������������������������������� 6 Gas Line Leak Testing�������������������������������������������������������������������� 22 Preparing for the Installation������������������������������������������������������������� 6 Purging�������������������������������������������������������������������������������������������� 22 Features And Components�������������������������������������������������������� 7 Startup and OPERATION������������������������������������������������������������� 23 High Limit Switch������������������������������������������������������������������������������� 7 Prior to Start Up������������������������������������������������������������������������������ 23 Electronic Ignition Control����������������������������������������������������������������� 7 Sequence of operation�������������������������������������������������������23-27 Barometric Draft Control������������������������������������������������������������������� 7 Sequence of Operation Flow Chart������������������������������������������������ 24 Combustion Chamber Observation Port������������������������������������������ 7 Lighting & Operation Label������������������������������������������������������������� 25 Uncrating������������������������������������������������������������������������������������������� 7 Adjustments������������������������������������������������������������������������������������ 26 Installation Considerations����������������������������������������������� 8-12 Checking Venting���������������������������������������������������������������������������� 26 Rough In Dimensions������������������������������������������������������������������������ 8 Checking the Input�������������������������������������������������������������������������� 26 Locating The Water Heater������������������������������������������������������������� 10 Setting Burner Operation���������������������������������������������������������������� 27 Clearances�������������������������������������������������������������������������������������� 10 maintenance������������������������������������������������������������������������������28-32 Insulation Blanket�����������������������������������������������������������������������������11 Venting System and Barometric Draft Control������������������������������� 28 Hard Water���������������������������������������������������������������������������������������11 General�������������������������������������������������������������������������������������������� 28 Circulation Pumps�����������������������������������������������������������������������11-12 Remote Storage Tank Temperature Control����������������������������������� 28 High Altitude Installations................................................................ 12 Temperature-Pressure Relief Valve Test���������������������������������������� 28 Installation Requirements������������������������������������������������ 13-16 Anode Rod Inspection�������������������������������������������������������������������� 29 Gas Supply Systems........................................................................ 13 Draining and Flushing��������������������������������������������������������������������� 29 Supply Gas Regulator��������������������������������������������������������������������� 13 Recommended Procedure for Periodic Removal or Lime Deposits from the Tank Type Commercial Water Heaters���������������������������� 29 Power Supply���������������������������������������������������������������������������������� 13 Water Temperature Control and Mixing Valves������������������������������ 13 DeLiming Solvents�������������������������������������������������������������������������� 30 Dishwashing Machines������������������������������������������������������������������� 14 Tank Cleanout Procedure��������������������������������������������������������������� 30 Closed Water Systems�������������������������������������������������������������������� 14 Deliming Using Flo-Jug Method.................................................30-31 Thermal Expansion������������������������������������������������������������������������� 14 Power Burner.............................................................................. 31-32 Temperature-Pressure Relief Valve������������������������������������������ 14-15 Gas Control Valve............................................................................ 32 Contaminated Air���������������������������������������������������������������������������� 15 service��������������������������������������������������������������������������������������������� 32 Air Requirements���������������������������������������������������������������������������� 15 Electrical Servicing������������������������������������������������������������������������� 32 Unconfined Space��������������������������������������������������������������������������� 16 Troubleshooting checklist��������������������������������������������������� 33 Confined Space������������������������������������������������������������������������������� 16 Venting Installation������������������������������������������������������������� 16-19 For your information���������������������������������������������������������������� 34 Venting�������������������������������������������������������������������������������������������� 16 Start up Conditions������������������������������������������������������������������������� 34 Barometric Draft Control Assembly������������������������������������������������ 16 Operational Conditions������������������������������������������������������������������� 34 Fresh Air Opening for Confined Spaces����������������������������������������� 17 Water Piping Diagrams����������������������������������������������������������35-49 Outdoor Air Through Two Openings����������������������������������������������� 17 MANIFOLD KITS��������������������������������������������������������������������������������� 50 Outdoor Air Through One Opening������������������������������������������������ 17 replacement parts list������������������������������������������������������� 51-52 Outdoor Air Through Two Horizontal Ducts������������������������������������ 17 Notes.............................................................................................53-54 Outdoor Air Through Two Vertical Ducts���������������������������������������� 18 Warranty���������������������������������������������������������������������������������������� 55 2 Safe Installation, Use and Service The proper installation, use and servicing of this water heater is extremely important to your safety and the safety of others. Many safety-related messages and instructions have been provided in this manual and on your own water heater to warn you and others of a potential injury hazard. Read and obey all safety messages and instructions throughout this manual. It is very important that the meaning of each safety message is understood by you and others who install, use, or service this water heater. This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death. DANGER DANGER indicates an imminently hazardous situation which, if not avoided, will result in injury or death. WARNING WARNING indicates a potentially hazardous situation which, if not avoided, could result in injury or death. CAUTION CAUTION indicates a potentially hazardous situation which, if not avoided, could result in minor or moderate injury. CAUTION CAUTION used without the safety alert symbol indicates a potentially hazardous situation which, if not avoided, could result in property damage. All safety messages will generally tell you about the type of hazard, what can happen if you do not follow the safety message, and how to avoid the risk of injury. The California Safe Drinking Water and Toxic Enforcement Act requires the Governor of California to publish a list of substances known to the State of California to cause cancer, birth defects, or other reproductive harm, and requires businesses to warn of potential exposure to such substances. WARNING: This product contains a chemical known to the State of California to cause cancer, birth defects, or other reproductive harm. This appliance can cause low level exposure to some of the substances listed in the Act. APPROVALS Low Lead Content Note: ASME construction is optional on the water heaters covered in this manual. 3 General Safety Information Fire or Explosion Hazard Fire Hazard Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. For continued protection against risk of fire: Avoid all ignition sources if you smell gas. Do not expose water heater controls to excessive gas pressure. Do not install water heater on carpeted floor. Do not operate water heater if flood damaged. Use only the gas shown on the water heater rating label. Maintain required clearances to combustibles. Keep ignition sources away from faucets after extended periods of non-use. Fire and Explosion Hazard Use joint compound or Teflon tape compatible with propane gas. Read instruction manual before installing, using or servicing water heater. Leak test before placing the water heater in operation. Disconnect gas piping and main gas shutoff valve before leak testing. Install sediment trap in accordance with NFPA 54. Fire and Explosion Hazard Do not use water heater with any gas other than the gas shown on the rating label. Excessive gas pressure to gas valve can cause serious injury or death. Turn off gas lines during installation. Contact a qualified installer or service agency for installation and service. CAUTION Property Damage Hazard • All water heaters eventually leak. Jumping out control circuits or components can result in property damage, personal injury or death. • Do not install without adequate drainage. • • Electrical Shock Hazard • Turn off power to the water heater before performing any service. • Label all wires prior to disconnecting when performing service. Wiring errors can cause improper and dangerous operation. • • Verify proper operation after servicing. • Service should only be performed by a qualified service agent using proper test equipment. Altering the water heater controls and/or wiring in any way could result in permanent damage to the controls or water heater and is not covered under the limited warranty. Altering the water heater controls and/or wiring in any way could result in altering the ignition sequence allowing gas to flow to the main burner before the hot surface igniter is at ignition temperature causing delayed ignition which can cause a fire or explosion. Any bypass or alteration of the water heater controls and/or wiring will result in voiding the water heater warranty. Failure to follow these instructions can result in personal injury or death. 4 General Safety Information Read and understand this instruction manual and the safety messages herein before installing, operating or servicing this water heater. Explosion Hazard Overheated water can cause water tank explosion. Failure to follow these instructions and safety messages could result in death or serious injury. Properly sized temperature and pressure relief valve must be installed in the opening provided. This manual must remain with the water heater. CAUTION Water temperature over 125°F (52°C) can cause severe burns instantly resulting in severe injury or death. Improper installation, use and service may result in property damage. Children, the elderly and the physically or mentally disabled are at highest risk for scald injury. • • • • • Feel water before bathing or showering. Temperature limiting devices such as mixing valves must be installed when required by codes and to ensure safe temperatures at fixtures. Do not operate water heater if flood damaged. Inspect anode rods regularly, replace if damaged. Install in location with drainage. Fill tank with water before operation. Properly sized thermal expansion tanks are required on all closed water systems. Refer to this manual for installation and service. Verify the power to the water heater is turned off before performing any service procedures. General Safety Information Precautions Hydrogen Gas Flammable DO NOT USE THIS water heater IF ANY PART HAS BEEN UNDER WATER. Immediately call a qualified service agency to inspect the water heater and to make a determination on what steps should be taken next. Explosion Hazard If the unit is exposed to the following, do not operate heater until all corrective steps have been made by a qualified service agency. Flammable hydrogen gases may be present. 1. External fire. Keep all ignition sources away from faucet when turning on hot water. 2. Damage. 3. Firing without water. Hydrogen gas can be produced in a hot water system served by this water heater that has not been used for a long period of time (generally two weeks or more). Hydrogen gas is extremely flammable. To reduce the risk of injury under these conditions, it is recommended that a hot water faucet served by this water heater be opened for several minutes before using any electrical appliance connected to the hot water system. If hydrogen is present there will probably be an unusual sound such as air escaping through the pipe as the water begins to flow. There should be no smoking or open flame near the faucet at the time it is open. GROUNDING INSTRUCTIONS This water heater must be grounded in accordance with the National Electrical Code and/or local codes. These must be followed in all cases. This water heater must be connected to a grounded, permanent wiring system; or an equipment grounding conductor must be run with the circuit conductors and connected to the equipment grounding terminal or lead on the water heater, see Figure 19. 5 Introduction Thank You for purchasing this water heater. Properly installed and maintained, it should give you years of trouble free service. Abbreviations Used Warranty on this product is limited and could be void in the event the unit is not installed per the instructions in this manual and/or not started up by an authorized factory trained service/ start-up provider. Abbreviations found in this Instruction Manual include : Preparing For The Installation • • • • • • • ANSI - American National Standards Institute ASME - American Society of Mechanical Engineers AHRI - Air-Conditioning, Heating and Refrigeration Institute NEC - National Electrical Code NFPA - National Fire Protection Association UL - Underwriters Laboratory CSA - Canadian Standards Association 1. Read the “General Safety” section, page 4-5 of this manual first and then the entire manual carefully. If you don’t follow the safety rules, the water heater will not operate properly. It could cause DEATH, SERIOUS BODILY INJURY AND/OR PROPERTY DAMAGE. Qualifications Qualified Installer or Service Agency Installation and service of this water heater requires ability equivalent to that of a Qualified Agency (as defined by ANSI below) in the field involved. Installation skills such as plumbing, air supply, venting, gas supply and electrical supply are required in addition to electrical testing skills when performing service. This manual contains instructions for the installation, operation, and maintenance of the gas-fired water heater. It also contains warnings throughout the manual that you must read and be aware of. All warnings and all instructions are essential to the proper operation of the water heater and your safety. Since we cannot put everything on the first few pages, READ THE ENTIRE MANUAL BEFORE ATTEMPTING TO INSTALL OR OPERATE THE WATER HEATER. 2. The installation must conform with these instructions and the local code authority having jurisdiction. In the absence of local codes, the installation must comply with the current editions of the National Fuel Gas Code, ANSI Z223.1/NFPA 54 or CAN/ CSA-B149.1 the Natural Gas and Propane Installation Code. All documents are available from the Canadian Standards Association, 8501 East Pleasant Valley Road, Cleveland, OH 44131. NFPA documents are also available from the National Fire Protection Association, 1 Batterymarch Park, Quincy, MA 02269. ANSI Z223.1 2006 Sec. 3.3.83: “Qualified Agency” - “Any individual, firm, corporation or company that either in person or through a representative is engaged in and is responsible for (a) the installation, testing or replacement of gas piping or (b) the connection, installation, testing, repair or servicing of appliances and equipment; that is experienced in such work; that is familiar with all precautions required; and that has complied with all the requirements of the authority having jurisdiction.” 3. If after reading this manual you have any questions or do not understand any portion of the instructions, call the local gas utility or the manufacturer whose name appears on the rating plate. If you are not qualified (as defined by ANSI above) and licensed or certified as required by the authority having jurisdiction to perform a given task do not attempt to perform any of the procedures described in this manual. If you do not understand the instructions given in this manual do not attempt to perform any procedures outlined in this manual. 4. Carefully plan the place where you are going to put the water heater. Correct combustion, vent action, and vent pipe installation are very important in preventing death from possible carbon monoxide poisoning and fires. START UP REQUIREMENTS This product requires a formal Start-Up by an authorized service/ Examine the location to ensure the water heater complies with the “Locating the New Water Heater” section in this manual. 5. For California installation this water heater must be braced, anchored, or strapped to avoid falling or moving during an earthquake. See instructions for correct installation procedures. Instructions may be obtained from California Office of the State Architect, 400 P Street, Sacramento, CA 95814. start-up provider that has been approved by the manufacturer for this specific product. Call 1-800-527-1953 to locate the nearest authorized start-up provider and arrange a factory start-up. Please provide as much notice as possible, preferably 2 weeks. Please have the model and serial number ready when you call. 6. Massachusetts Code requires this water heater to be installed in accordance with Massachusetts 248-CMR 2.00: State Plumbing Code and 248-CMR 5.00. This start-up is required to activate the warranty and ensure safe, efficient operation. 6 FEATURES AND COMPONENTS high limit switch BAROMETRIC DRAFT CONTROL The dual bulb controller (fig. 1) contains the high limit (energy cutoff) sensor. The high limit switch interrupts main burner gas flow should the water temperature reach 205°F (96°C). The heater is equipped with a double acting barometric draft control. This control assembly is factory adjusted to automatically regulate the chimney draft imposed on the unit. In the event of high limit switch operation, the appliance cannot be restarted unless the water temperature is reduced by at least 20°F (11°C) and the high limit reset button on front of limit control (fig.1) is depressed. Continued manual resetting of high limit control, preceded by higher than usual water temperature is evidence of high limit switch operation. The following is a possible reason for high limit switch operation: • A malfunction in the thermostatic controls would allow the gas control valve to remain open causing water temperature to exceed the thermostat setting. The water temperature would continue to rise until high limit switch operation. Contact your dealer or service agent if continued high limit switch operation occurs. BAROMETRIC DRAFT CONTROL FIGURE 3. COMBUSTION CHAMBER OBSERVATION PORT The combustion chamber observation access panel is located above and to the left of the burner. A plug located under the panel, see fig. 5, is inserted into the combustion chamber wall. This plug should not be removed except, in rare cases, when the combustion chamber requires cleaning or replacement. DIGITAL THERMOSTAT FIGURE 1. electronic ignition control Each heater is equipped with a Honeywell ignition module. The Direct Spark Ignition Control Module controls the ignition sequence and gas control operation of the water heater. FIGURE 4. uncrating Uncrate the heater by removing the outside mat and top locator. The shipping pallet must be removed from the unit. It may be possible to simply unbolt the base from the pallet and, with the help of 2 or more persons, work the unit off the pallet. Some units will be too heavy and will require the use of jacks or lifting equipment to safely remove the pallet and move the unit into position. Be careful when moving this heater. It will tip over easily. The heater is shipped with a burner and draft control. The burner and draft control are shipped in separate cartons. They should be installed as received without any alterations. Discard the shipping crate and packaging cartons in an appropriate manner. IGNITION MODULE FIGURE 2. 7 installation considerations Rough In Dimensions FIGURE 5. TABLE 1 . Models BTP-139(A) Through BTP-370(A) APPROX. SHIP. WT. MODELS A B C D E G H J (LBS.) GAS ASME IN OUT STD. BTP-139/A 74 3/4" 65" 26 3/4" 6" 21 3/8" 27 3/4" 38" 85 1/4" 1/2 658 556 1 1/2" 1 1/2" BTP-199/A BTP-270/A 74 3/4" 74 3/4" 65" 65" 26 3/4" 26 3/4" 6" 8" 21 3/8" 21 3/8" 27 3/4" 27 3/4" 38" 38" 85 1/4" 85 1/4" 1/2 3/4 635 632 545 547 1 1/2" 1 1/2" 1 1/2" 1 1/2" BTP-370/A 74 3/4" 65" 26 3/4" 8" 21 3/8" 27 3/4" 38" 85 1/4" 3/4 731 634 1 1/2" 1 1/2" 8 installation considerations TABLE 2. HEATER PERFORMANCE DATA BTP MODELS STORAGE CAPACITY U.S. GALLONS MODELS IMPUT RATING BTU/HR. RECOVERY RATE [email protected]°F RISE RECOVERY RATE [email protected]°F RISE MAXIMUM AMPERES 120V, 60Hz, 10 BTP-139/A 81 140,000 136 97 5 BTP-199/A 81 199,000 193 138 5 BTP-270/A 81 270,000 262 187 5 BTP-370/A 81 370,000 359 256 5 Models with letter “A” following the model number have the optional ASME tank construction. **The BTP-370 is available in natural gas only. TABLE 3. GAS AND ELECTRICAL CHARACTERISTICS Gas Supply Pressure Model Type of Gas Minimum Maximum Gas Manifold Pressure Volts/Hz Amperes All Models Natural 4.5" W.C. (1.12 kPa) 14" W.C. (3.48 kPa) 3.5" W.C. (0.87 kPa) 120/60 <5 All Models * Propane 4.5" W.C. (1.12 kPa) 14" W.C. (3.48kPa) 3.5" W.C. (0.87 kPa) 120/60 <5 * Model BTP-370(A) is not available in Propane 9 Installation Considerations locating the water heater The heater must not be located in an area where it will be subject to freezing. CAUTION Locate it near a floor drain. The heater should be located in an area where leakage from heater or connections will not result in damage to adjacent area or to lower floors of the structure. Property Damage Hazard • All water heaters eventually leak. When such locations cannot be avoided, a suitable metal drain pan should be installed under heater. Such pans should be fabricated with sides at least 2” deep, with length and width at least 2” greater than diameter of heater and must be piped to an adequate drain. Pan must not restrict combustion air flow. • Do not install without adequate drainage. When installing the heater, consideration must be given to proper location. Location selected should be as close to the stack or chimney as practicable, with adequate air supply and as centralized with the piping system as possible. clearances These heaters are approved for installation on non-combustible flooring in an alcove when the minimum clearance from combustion or non-combustible construction are followed as indicated in Figure 7 and Table 5. Fire or Explosion Hazard Units which are to be installed on combustible flooring must be supported by a full layer of hollow concrete blocks, from 8" to 12" Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. thick and extending 12" (minimum) beyond the heater in all directions. The concrete blocks must provide an unbroken concrete surface under the heater with the hollows running continuously and horizontally. A 3/16 inch steel plate must cover the concrete blocks. See Figure 5. Avoid all ignition sources if you smell gas. Do not expose water heater controls to excessive gas pressure. Use only the gas shown on the water heater rating label. Maintain required clearances to combustibles. Keep ignition sources away from faucets after extended periods of non-use. Read instruction manual before installing, using or servicing water heater. PROPER INSTALLATION ON COMBUSTIBLE FLOORING There is a risk in using fuel burning appliances such as gas water heaters in rooms, garages or other areas where gasoline, other flammable liquids or engine driven equipment or vehicles are stored, operated or repaired. Flammable vapors are heavy and travel along the floor and may be ignited by the heater’s igniter or main burner flames causing fire or explosion. Some local codes permit operation of gas appliances in such areas if they are installed 18” or more above the floor. This may reduce the risk if location in such an area cannot be avoided. In all installations the minimum combustible clearances from barometric draft control surface or vent piping shall be 6” (152mm). Vent piping passing through a combustible wall or ceiling must be a continuous run (no joints) and retain 6” (152mm) clearance unless an approved reducing thimble is used. Do not install this water heater directly on a carpeted floor. A fire hazard may result. Instead the water heater must be placed on a metal or wood panel extending beyond the full width and depth by at least 3 inches in any direction. If the heater is installed in a carpeted alcove, the entire floor shall be covered by the panel. Also, see the DRAINING requirements in MAINTENANCE Section. TABLE 5. Installation Clearances FIGURE 6. A service clearance of 24” (610mm) should be maintained from serviceable parts, such as relief valves, baffles, thermostats, cleanout openings or drain valves. The heater shall be located or protected so it is not subject to physical damage by a moving vehicle. Flammable items, pressurized containers or any other potential fire hazardous articles must never be placed on or adjacent to the heater. Open containers or flammable material should not be stored or used in the same room with the heater. 10 A B C D (RIGHT SIDE) (LEFTSIDE) (BACK) (CEILING) BTP-139(A) 6" (15.24 cm) 6" (15.24 cm) 6" (15.24 cm) 21" (53.34 cm) BTP-199(A) 6" (15.24 cm) 6" (15.24 cm) 6" (15.24 cm) 21" (53.34 cm) BTP-270(A) 6" (15.24 cm) 6" (15.24 cm) 6" (15.24 cm) 21" (53.34 cm) BTP-370(A) 6" (15.24 cm) 6" (15.24 cm) 6" (15.24 cm) 24" (60.96 cm) is to reduce the standby heat loss encountered with storage tank heaters. The water heaters covered by this manual meet or exceed the Energy Policy Act standards with respect to insulation and standby heat loss requirements, making an insulation blanket unnecessary. Should you choose to apply an insulation blanket to this heater, you should follow these instructions. See the Features and Components section of this manual for identification of components mentioned below. Failure to follow these instructions can restrict the air flow required for proper combustion, potentially resulting in fire, asphyxiation, serious personal injury or death. • • • • • • DO NOT apply insulation to the top of the water heater, as this will interfere with safe operation of the draft control. DO NOT cover the gas control valve, thermostat or the Temperature-Pressure Relief Valve. DO NOT allow insulation to come within 2” (5 cm) of the burners, to prevent blockage of combustion air flow to the burners. DO NOT cover the instruction manual. Keep it on the side of the water heater or nearby for future reference. DO obtain new warning and instruction labels from the manufacturer for placement on the blanket directly over the existing labels. DO inspect the insulation blanket frequently to make certain it does not sag, thereby obstructing combustion air flow. HARD WATER Where hard water conditions exist, water softening or the threshold type of water treatment is recommended. This will protect the dishwashers, coffee urns, water heaters, water piping and other equipment. See the Maintenance Section in this manual for sediment and lime scale removal procedures. Figure 7. INSULATION BLANKET Circulation pumps A circulating pump is used when a system requires a circulating loop or there is a storage tank used in conjunction with the water heater. See Water Piping Diagrams in this manual for installation location of circulating pumps. Breathing Hazard - Carbon Monoxide Gas Do not obstruct water heater air intake with insulating blanket. See the Circulation Pump Wiring Diagrams in this manual for electrical hookup information. Install in accordance with the current edition of the National Electrical Code, NFPA 70 or the Canadian Electrical Code, CSA C22.1. Gas and carbon monoxide detectors are available. Install water heater in accordance with the instruction manual. All-bronze circulating pumps are recommended for used with commercial water heaters. Breathing carbon monoxide can cause brain damage or death. Always read and understand instruction manual. Some circulating pumps are manufactured with sealed bearings and do not require further lubrication. Some circulating pumps must be periodically oiled. Refer to the pump manufacturer’s instructions for lubrication requirements. Insulation blankets are available to the general public for external use on gas water heaters but are not necessary with these products. The purpose of an insulation blanket 11 CIRCULATING PUMP WIRING DIAGRAM DISHWASHER LOOP WITH TOGGLE SWITCH CIRCULATING PUMP WIRING DIAGRAM STORAGE TANK OR BUILDING RECIRCULATION FIELD SUPPLIED TEMPERATURE CONTROL INSTALLED IN THE STORAGE TANK OR CIRCULATING LOOP RETURN LINE DISHWASHER FIELD SUPPLIED TEMPERATURE SWITCH CIRCULATING LOOP RETURN LINE BreathingTOGGLE Hazard - Carbon Gas CONTROL Monoxide INSTALLED IN THE NOTE: USE SEPARATE 120 VAC POWER SUPPLY FOR PUMP CIRCUIT. DO NOT SHARE POWER WITH WATER HEATER AS THIS MAY CAUSE ELECTRICAL LINE NOISE AND LEAD TO ERRATIC CONTROL SYSTEM OPERATION. Under no circumstances should NOTE: USE SEPARATE 120 VAC POWER the input exceed the rate shown SUPPLY FOR PUMP CIRCUIT. DO NOT SHARE POWER WITH WATER HEATER AS THIS MAY on the water heater’s rating label. CAUSE ELECTRICAL LINE NOISE AND LEAD TO ERRATIC CONTROL SYSTEM OPERATION. L1 HOT Overfiring could result in damage to the water heater and sooting. L1 HOT 120 VAC POWER CIRC PUMP MOTOR 120 VAC POWER MOTOR L2 NEUTRAL Breathing carbon monoxide can cause brain damage or L2 NEUTRAL death. Always read and understand instruction manual. FIGURE 8. CIRCULATING PUMP WIRING DIAGRAM DISHWASHER LOOP WITH TOGGLE SWITCH ONTROL DISHWASHER TOGGLE SWITCH NE Gas and carbon monoxide detectors CIRC are available. PUMP Installations above 2000 feet (610 meters) require replacement of burner orifices in accordance with current edition of the National Fuel Gas Code (ansi z223.1). For Canadian installations consult Canadian Installations Code can/csa b149.1. Failure to replace orifices will result in improper and inefficient operation of the water heater resulting in the production of increased levels of carbon monoxide gas in excess of safe limits which could result in serious personal injury or death. FIELD SUPPLIED TEMPERATURE CONTROL INSTALLED IN THE CIRCULATING LOOP RETURN LINE NOTE: USE SEPARATE 120 VAC POWER SUPPLY FOR PUMP CIRCUIT. DO NOT SHARE POWER WITH WATER HEATER AS THIS MAY CAUSE ELECTRICAL LINE NOISE AND LEAD TO ERRATIC CONTROL SYSTEM OPERATION. L1 HOT 120 VAC POWER You should contact your gas supplier for any specific changes which may be required in your area. CIRC PUMP MOTOR As the elevation above sea level is increased, there is less oxygen per cubic foot of air. Therefore, the heater input rate should be reduced at high altitudes for satisfactory operation with the reduced oxygen supply. Failure to make this reduction would result in an over firing of the heater causing sooting, poor combustion and/or unsatisfactory heater performance. L2 NEUTRAL FIGURE 9. HIGH ALTITUDE INSTALLATIONS Ratings specified by manufacturers for most appliances apply for elevations up to 2000 feet (610m). For elevations above 2000 feet (610), ratings must be reduced at the rate of 4% for each 1000 feet (305m) above sea level. For example, if a heater is rated at 78,000 Btuh (22.9 Kwh) at sea level, to rate the heater at 4000 feet (1219m), you subtract 4 (once for each thousand feet) x.04 (4% input reduction) x 78,000 (original rating) from the original rating. Fire and Explosion Hazard Under no circumstances should the input exceed the rate shown on the water heater’s rating label. Overfiring could result in fire or explosion. Gas and carbon monoxide detectors are available. Therefore, to calculate the input rating at 4,000 feet (1219m): 4 x .04 x 78,000 = 12,480 Btuh (3.7 Kwh), 78,000 (22.9 Kwh) 12,480 (3.7 Kwh) = 65,520 Btuh (19.2 Kwh). At 6000 feet (1829m) the correct input rating should be 59,280 Btuh (17.4 Kwh). 12 Installation Requirements 4. When installing multiple water heaters in the same gas supply system it is recommended that individual positive lock-up gas pressure regulators be installed at each unit. Gas supply Systems Low pressure building gas supply systems are defined as those systems that cannot under any circumstances exceed 14” W.C. (1/2 PSI Gauge). These systems do not require pressure regulation. Measurements should be taken to insure that gas pressures are stable and fall within the requirements stated on the water heater rating plate. Readings should be taken with all gas burning equipment off (static pressure) and with all gas burning equipment running at maximum rate (dynamic pressure). The gas supply pressure must be stable within 1.5” W.C. from static to dynamic pressure to provide good performance. Pressure drops that exceed 1.5” W.C. may cause rough starting, noisy combustion or nuisance outages. Increases or spikes in static pressure during off cycles may cause failure to ignite or in severe cases damage to appliance gas valves. If your low pressure system does NOT meet these requirements, the installer is responsible for the corrections. Power Supply The water heaters covered in this manual require a 120 VAC, 1Ø (single phase), 60Hz, 15 amp power supply and must also be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/ NFPA 70 or the Canadian Electrical Code, CSA C22.1. WATER TEMPERATURE CONTROL AND Mixing Valves Water temperature over 125°F (52°C) can cause severe burns instantly resulting in severe injury or death. Children, the elderly and the physically or mentally disabled are at highest risk for scald injury. High Pressure building supply systems use pressures that exceed 14” W.C. (1/2 PSI Gauge). These systems must use field supplied regulators to lower the gas pressure to less than 14” W.C. (1/2 PSI Gauge). Water heaters require gas regulators that are properly sized for the water heater input and deliver the rating plate specified pressures. Gas supply systems where pressure exceeds 5 PSI often require multiple regulators to achieve desired pressures. Systems in excess of 5 PSI building pressure should be designed by gas delivery professionals for best performance. Water heaters connected to gas supply systems that exceed 14” W.C. (1/2 PSI Gauge) at any time must be equipped with a gas supply regulator. Feel water before bathing or showering. Temperature limiting devices such as mixing valves must be installed when required by codes and to ensure safe temperatures at fixtures. Water heated to a temperature which will satisfy clothes washing, dish washing, and other sanitizing needs can scald and cause permanent injury upon contact. Short repeated heating cycles caused by small hot water uses can cause temperatures at the point of use to exceed the water heater’s temperature setting by up to 20°F (11°C). All models require a minimum gas supply pressure of 4.5" W.C. for natural gas and propane gas. The minimum supply pressure is measured while gas is flowing (dynamic pressure). The supply pressure should never fall below 4.5" W.C. for natural gas and propane gas. The supply pressure should be measured with all gas fired appliances connected to the common main firing at full capacity. If the supply pressure drops more than 1.5” W.C. as gas begins to flow to the water heater then the supply gas system including the gas line and/or the gas regulator may be restricted or undersized. See Supply Gas Regulator section and Gas Piping section of this manual. The gas valve on all models has a maximum gas supply pressure limit of 14” W.C. The maximum supply pressure is measured while gas is not flowing (static pressure). Some people are more likely to be permanently injured by hot water than others. These include the elderly, children, the infirm and the physically/mentally disabled. Table 6 shows approximate time-to-burn relationship for normal adult skin. If anyone using hot water provided by the water heater being installed fits into one of these groups or if there is a local code or state law requiring a certain water temperature at the point of use, then special precautions must be taken. In addition to using the lowest possible temperature setting that satisfies the demand of the application a Mixing Valve should be installed at the water heater (see Figure 10) or at the hot water taps to further reduce system water temperature. Mixing valves are available at plumbing supply stores. Consult a Qualified Installer or Service Agency. Follow mixing valve manufacturer’s instructions for installation of the valves. SUPPLY GAS REGULATOR The maximum allowable gas supply pressure for this water heater is 14" W.C. (3.48 kPa). Install a positive lock-up gas pressure regulator in the gas supply line if inlet gas pressure can exceed 14" W.C. (3.48 kPa) at any time. Regulators must be sized/used according to manufacturer’s specifications. If a positive lock-up regulator is required follow these instructions: 1. Positive lock-up gas pressure regulators must be rated at or above the input Btu/hr rating of the water heater they supply. 2. Positive lock-up gas pressure regulator(s) should be installed no closer than 3 equivalent feet (1 meter) and no farther than 8 equivalent feet (2.4 meters) from water heater’s inlet gas connection. 3. After installing the positive lock-up gas pressure regulator(s), an initial nominal supply pressure setting of 7" W.C. (1.74 kPa) while water heater is operating is recommended and will generally provide good water heater operation. Some additional adjustment maybe required later to maintain a steady gas supply pressure. Table 6. Water Temperature °F Time for 1st Degree Burn (Less Severe Burns) 110 116 116 122 131 140 149 154 (normal shower temp.) (pain threshold) 35 minutes 1 minute 5 seconds 2 seconds 1 second instantaneous Time for Permanent Burns 2nd & 3rd Degree (Most Severe Burns) 45 minutes 5 minutes 25 seconds 5 seconds 2 seconds 1 second (U.S. Government Memorandum, C.P.S.C., Peter L. Armstrong, Sept. 15,1978) 13 A properly sized thermal expansion tank must be installed on all closed systems to control the harmful effects of thermal expansion. Contact a local plumbing service agency to have a thermal expansion tank installed. HOT WATER OUTLET See Water Line Connections on page 19 and the Water Piping Diagrams beginning on page 35. 12” TO 15” (30-38 cm) TEMPERED WATER OUTLET Temperature-pressure relief valve CHECK VALVE COLD WATER INLET CHECK VALVE Explosion Hazard MIXING VALVE Temperature-Pressure Relief Valve must comply with ANSI Z21.22CSA 4.4 and ASME code. TO TANK INLET Properly sized temperaturepressure relief valve must be installed in opening provided. FIGURE 10. Dishwashing Machines Can result in overheating and excessive tank pressure. All dishwashing machines meeting the National Sanitation Foundation requirements are designed to operate with water flow pressures between 15 and 25 pounds per square inch (103 kPa and 173 kPa). Flow pressures above 25 pounds per square inch (173 kPa), or below 15 pounds per square inch (103 kPa), will result in improperly sanitized dishes. Where pressures are high, a water pressure reducing or flow regulating control valve should be used in the 180°F (82°C) line to the dishwashing machine and should be adjusted to deliver water pressure between these limits. Can cause serious injury or death. This water heater is provided with a properly rated/sized and certified combination Temperature-Pressure Relief Valve (T&P valve) by the manufacturer. The valve is certified by a nationally recognized testing laboratory that maintains periodic inspection of production of listed equipment of materials as meeting the requirements for Pressure Relief Valves for Hot Water Supply Systems, ANSI Z21.22 • CSA 4.4, and the code requirements of ASME. The National Sanitation Foundation also recommends circulation of 180°F (82°C) water. The circulation flow rate should be just enough to provide 180°F (82°C) water at the point of take-off to the dishwashing machine. If replaced, the new T&P valve must meet the requirements of local codes, but not less than a combination TemperaturePressure Relief Valve rated/sized and certified as indicated in the above paragraph. The new valve must be marked with a maximum set pressure not to exceed the marked hydrostatic working pressure of the water heater (150 psi = 1,035 kPa) and a discharge capacity not less than the water heater Btu/hr or kW input rate as shown on the water heater’s model rating label. Adjust flow by throttling a full port ball valve installed in the circulating line on the outlet side of the pump. Never throttle flow on the suction side of a pump. See Water Piping Diagrams in this manual. Closed Water Systems NOTE: In addition to the factory installed Temperature-Pressure Relief Valve on the water heater, each remote storage tank that may be installed and piped to a water heating appliance must also have its own properly sized, rated and approved TemperaturePressure Relief Valve installed. Call the toll free technical support phone number listed on the back cover of this manual for technical assistance in sizing a Temperature-Pressure Relief Valve for remote storage tanks. Water supply systems may, because of code requirements or such conditions as high line pressure, among others, have installed devices such as pressure reducing valves, check valves, and back flow preventers. Devices such as these cause the water system to be a closed system. Thermal Expansion For safe operation of the water heater, the Temperature-Pressure Relief Valve must not be removed from its designated opening nor plugged. The Temperature-Pressure Relief Valve must be installed directly into the fitting of the water heater designed for the pressure relief valve . Install discharge piping so that any discharge will exit the pipe within 6 inches (15.2 cm) above an adequate floor drain, or external to the building. In cold climates it is recommended that it be terminated at an adequate drain inside the building. Be certain that no contact is made with any live electrical part. The discharge opening must not be blocked or reduced in size under any circumstances. Excessive length, over 30 feet (9.14 m), or use of more than four elbows can cause restriction and reduce the discharge capacity of the valve. As water is heated, it expands (thermal expansion). In a closed system the volume of water will grow when it is heated. As the volume of water grows there will be a corresponding increase in water pressure due to thermal expansion. Thermal expansion can cause premature tank failure (leakage). This type of failure is not covered under the limited warranty. Thermal expansion can also cause intermittent TemperaturePressure Relief Valve operation: water discharged from the valve due to excessive pressure build up. This condition is not covered under the limited warranty. The TemperaturePressure Relief Valve is not intended for the constant relief of thermal expansion. 14 Contaminated Air No valve or other obstruction is to be placed between the Temperature-Pressure Relief Valve and the tank. Do not connect discharge piping directly to the drain unless a 6” (15.2 cm) air gap is provided. To prevent bodily injury, hazard to life, or property damage, the relief valve must be allowed to discharge water in adequate quantities should circumstances demand. If the discharge pipe is not connected to a drain or other suitable means, the water flow may cause property damage. Breathing Hazard - Carbon Monoxide Gas Install water heater in accordance with the Instruction Manual and NFPA 54 or CAN/CSA-B149.1. To avoid injury, combustion and ventilation air must be taken from outdoors. Do not place chemical vapor emitting products near water heater. CAUTION Water Damage Hazard • Temperature-Pressure Relief Valve discharge Breathing carbon monoxide can cause brain damage or death. Always read and understand instruction manual. pipe must terminate at adequate drain. Corrosion of the flue ways and vent system may occur if air for combustion contains certain chemical vapors. Such corrosion may result in failure and risk of asphyxiation. T&P Valve Discharge Pipe Requirements: • Shall not be smaller in size than the outlet pipe size of the valve, or have any reducing couplings or other restrictions. • Shall not be plugged or blocked. • Shall not be exposed to freezing temperatures. • Shall be of material listed for hot water distribution. • Shall be installed so as to allow complete drainage of both the Temperature-Pressure Relief Valve and the discharge pipe. • Must terminate a maximum of six inches above a floor drain or external to the building. In cold climates, it is recommended that the discharge pipe be terminated at an adequate drain inside the building. • Shall not have any valve or other obstruction between the pressure relief valve and the drain. Combustion air that is contaminated can greatly diminish the life span of the water heater and water heater components such as hot surface igniters and burners. Propellants of aerosol sprays, beauty shop supplies, water softener chemicals and chemicals used in dry cleaning processes that are present in the combustion, ventilation or ambient air can cause such damage. Do not store products of this sort near the water heater. Air which is brought in contact with the water heater should not contain any of these chemicals. If necessary, uncontaminated air should be obtained from remote or outdoor sources. The limited warranty is voided when failure of water heater is due to a corrosive atmosphere. (See limited warranty for complete terms and conditions). Air requirements Burn hazard. Hot water discharge. Breathing Hazard - Carbon Monoxide Gas Install water heater in accordance with the Instruction Manual and NFPA 54 or CAN/CSA-B149.1. To avoid injury, combustion and ventilation air must be taken from outdoors. Do not place chemical vapor emitting products near water heater. Keep clear of TemperaturePressure Relief Valve discharge outlet. The Temperature-Pressure Relief Valve must be manually operated at least twice a year. Caution should be taken to ensure that (1) no one is in front of or around the outlet of the Temperature-Pressure Relief Valve discharge line, and (2) the water manually discharged will not cause any bodily injury or property damage because the water may be extremely hot. If after manually operating the valve, it fails to completely reset and continues to release water, immediately close the cold water inlet to the water heater, follow the draining instructions in this manual, and replace the TemperaturePressure Relief Valve with a properly rated/sized new one. Breathing carbon monoxide can cause brain damage or death. Always read and understand instruction manual. For safe operation an adequate supply of fresh uncontaminated air for combustion and ventilation must be provided. An insufficient supply of air can cause recirculation of combustion products resulting in contamination that may be hazardous to life. Such a condition often will result in a yellow, luminous burner flame, causing sooting of the combustion chamber, burners and flue tubes and creates a risk of asphyxiation. NOTE: The purpose of a Temperature-Pressure Relief Valve is to prevent excessive temperatures and pressures in the storage tank. The T&P valve is not intended for the constant relief of thermal expansion. A properly sized thermal expansion tank must be installed on all closed systems to control thermal expansion, see Closed Water Systems and Thermal Expansion on page 14. Do not install the water heater in a confined space unless an adequate supply of air for combustion and ventilation is brought in to that space using the methods described in the Confined Space section that follows. If you do not understand these instructions or have any questions regarding the Temperature-Pressure Relief Valve call the toll free number listed on the back cover of this manual for technical assistance. Never obstruct the flow of ventilation air. If you have any doubts or questions at all, call your gas supplier. Failure to provide the proper amount of combustion air can result in a fire or explosion and cause property damage, serious bodily injury or death. 15 Unconfined Space Direct Vent Appliances An Unconfined Space is one whose volume IS NOT LESS THAN 50 cubic feet per 1,000 Btu/hr (4.8 cubic meters per kW) of the total input rating of all appliances installed in the space. Rooms communicating directly with the space, in which the appliances are installed, through openings not furnished with doors, are considered a part of the unconfined space. Appliances installed in a Direct Vent configuration that derive all air for combustion from the outdoor atmosphere through sealed intake air piping are not factored in the total appliance input Btu/ hr calculations used to determine the size of openings providing fresh air into confined spaces. Makeup air requirements for the operation of exhaust fans, kitchen ventilation systems, clothes dryers and fireplaces shall also be considered in determining the adequacy of a space to provide combustion, ventilation and dilution air. Where exhaust fans are installed, additional air shall be provided to replace the exhausted air. When an exhaust fan is installed in the same space with a water heater, sufficient openings to provide fresh air must be provided that accommodate the requirements for all appliances in the room and the exhaust fan. Undersized openings will cause air to be drawn into the room through the water heater’s vent system causing poor combustion. Sooting, serious damage to the water heater and the risk of fire or explosion may result. It can also create a risk of asphyxiation. Exhaust Fans Unusually Tight Construction In unconfined spaces in buildings, infiltration may be adequate to provide air for combustion, ventilation and dilution of flue gases. However, in buildings of unusually tight construction (for example, weather stripping, heavily insulated, caulked, vapor barrier, etc.) additional air must be provided using the methods described in the Confined Space section that follows. Louvers and Grilles The free areas of the fresh air openings in the instructions that follow do not take in to account the presence of louvers, grilles or screens in the openings. Confined Space The required size of openings for combustion, ventilation and dilution air shall be based on the “net free area” of each opening. Where the free area through a design of louver or grille or screen is known, it shall be used in calculating the size of opening required to provide the free area specified. Where the louver and grille design and free area are not known, it shall be assumed that wood louvers will have 25% free area and metal louvers and grilles will have 75% free area. Non motorized louvers and grilles shall be fixed in the open position. A Confined Space is one whose volume is less than 50 cubic feet per 1,000 Btu/hr (4.8 cubic meters per kW) of the total input rating of all appliances installed in the space. Openings must be installed to provide fresh air for combustion, ventilation and dilution in confined spaces. The required size for the openings is dependent on the method used to provide fresh air to the confined space and the total Btu/hr input rating of all appliances installed in the space. VENTING INSTALLATION venting to face in direction needed. The assembly must be fitted to the jacket cover such that it is plumb and level to the ground. Fasten the draft control assembly to the top cover using sheet metal screws at three locations, or more, as required. THE INSTRUCTIONS IN THIS SECTION ON VENTING MUST BE FOLLOWED TO AVOID CHOKED COMBUSTION OR RECIRCULATION OF FLUE GASES. SUCH CONDITIONS CAUSE SOOTING OR RISKS OF FIRE AND ASPHYXIATION. Dampers or other obstructions must not be installed between the heater and the barometric draft control assembly. Heater must be protected from freezing downdrafts. Do not adjust settings on gate. Counterweight washers are factory adjusted and should result in breeching pressure measurements at the combustion test hole (Figure 11) within the range shown in Table 10. Remove all soot or other obstructions from the chimney that will retard a free draft. Type B venting is recommended with these heaters. NOTE: A negative draft must be maintained in the vent piping. When installed, the damper gate must pivot freely in the ring guides. This gate will automatically adjust to regulate the chimney draft imposed on the heater. This water heater must be vented in compliance with all local codes, the current revision of the National Fuel Gas Code (ANSI-Z223.1) and with the Category I Venting Tables. If any part of the vent system is exposed to ambient temperatures below 40°F (4.4°C) it must be insulated to prevent condensation. • Do not connect the heater to a common vent or chimney with solid fuel burning equipment. This practice is prohibited by many local building codes as is the practice of venting gas fired equipment to the duct work of ventilation systems. • Where a separate vent connection is not available and the vent pipe from the heater must be connected to a common vent with an oil burning furnace, the vent pipe should enter the smaller common vent or chimney at a point above the large vent pipe. BAROMETRIC DRAFT CONTROL ASSEMBLY A double-acting barometric draft control assembly is provided with each unit. The draft control assembly must be installed without alteration. This assembly is factory adjusted for horizontal application only and must be attached to the heater as shown in Figure 11. The outlet of the draft control assembly may be rotated PROPER DRAFT CONTROLLER AND VENT PIPE INSTALLATION FIGURE 11. 16 Fresh Air Openings For Confined Spaces Alternatively a single permanent opening, commencing within 12 inches (300 mm) of the top of the enclosure, shall be provided. See Figure 12. The water heater shall have clearances of at least 1 inch (25 mm) from the sides and back and 6 inches (l50 mm) from the front of the water heater. The opening shall directly communicate with the outdoors or shall communicate through a vertical or horizontal duct to the outdoors or spaces that freely communicate with the outdoors and shall have a minimum free area of the following: The following instructions shall be used to calculate the size, number and placement of openings providing fresh air for combustion, ventilation and dilution in confined spaces. The illustrations shown in this section of the manual are a reference for the openings that provide fresh air into confined spaces only. DO NOT refer to these illustrations for the purpose of vent installation. See Venting Installation on page 16 for complete venting installation instructions. 1. 1 square inch per 3000 Btu/hr (733 mm 2 per kW) of the total input rating of all appliances located in the enclosure, and Outdoor Air Through Two Openings 2. Not less than the sum of the areas of all vent connectors in the space. Outdoor Air Through Two Horizontal Ducts Figure 12. The confined space shall be provided with two permanent openings, one commencing within 12 inches (300 mm) of the top and one commencing within 12 inches (300 mm) of the bottom of the enclosure. The openings shall communicate directly with the outdoors. See Figure 12. Each opening shall have a minimum free area of 1 square inch per 4,000 Btu/hr (550 mm2 per kW) of the aggregate input rating of all appliances installed in the enclosure. Each opening shall not be less than 100 square inches (645 cm2). Figure 14. The confined space shall be provided with two permanent horizontal ducts, one commencing within 12 inches (300 mm) of the top and one commencing within 12 inches (300 mm) of the bottom of the enclosure. The horizontal ducts shall communicate directly with the outdoors. See Figure 14. Outdoor Air Through One Opening Each duct opening shall have a minimum free area of 1 square inch per 2,000 Btu/hr (1100 mm2 per kW) of the aggregate input rating of all appliances installed in the enclosure. When ducts are used, they shall be of the same cross sectional area as the free area of the openings to which they connect. The minimum dimension of rectangular air ducts shall be not less than 3 inches. Figure 13. 17 Outdoor Air Through Two Vertical Ducts When ducts are used, they shall be of the same cross sectional area as the free area of the openings to which they connect. The minimum dimension of rectangular air ducts shall be not less than 3" (76.2 mm). The illustrations shown in this section of the manual are a reference for the openings that provide fresh air into confined spaces only. Air From Other Indoor Spaces Do not refer to these illustrations for the purpose of vent installation. See Venting Installation on page 14 for complete venting installation instructions. Figure 16. The confined space shall be provided with two permanent openings, one commencing within 12 inches (300 mm) of the top and one commencing within 12 inches (300 mm) of the bottom of the enclosure. See Figure 16. Figure 15. The confined space shall be provided with two permanent vertical ducts, one commencing within 12 inches (300 mm) of the top and one commencing within 12 inches (300 mm) of the bottom of the enclosure. The vertical ducts shall communicate directly with the outdoors. See Figure 15. Each opening shall communicate directly with an additional room(s) of sufficient volume so that the combined volume of all spaces meets the criteria for an Unconfined Space. Each opening shall have a minimum free area of 1 square inch per 1,000 Btu/hr (2200 mm2 per kW) of the aggregate input rating of all appliances installed in the enclosure. Each opening shall not be less than 100 square inches (645 cm2). Each duct opening shall have a minimum free area of 1 square inch per 4,000 Btu/hr (550 mm2 per kW) of the aggregate input rating of all appliances installed in the enclosure. 18 VENT CONNECTION Where an existing chimney or vent is to be used, be sure that the chimney or vent has adequate capacity for the number and sizes of gas appliances being vented through it. Inspect the chimney or vent and remove all soot or other obstructions which will retard free draft. Vent connections must be made to an adequate stack or chimney. Refer to the National Fuel Gas Code (current edition) or to the vent pipe manufacturer’s gas vent and chimney sizing table to properly design and size the venting system. Refer to Table 7 for the vent pipe size required for installation to the barometric draft control assembly outlet. Vent connectors making horizontal runs must have a minimum upward slope toward the chimney or vent of 1/4 inch per foot. Vent connector length should be kept as short as possible. Be sure that the vent pipe does not extend beyond the inside wall of a chimney. TABLE 7. BAROMETRIC DRAFT CONTROL ASSEMBLY OUTLET SIZE MODEL DRAFT CONTROL OUTLET DIAMETER BTP-139/A 6” BTP-199/A 6” BTP-270/A 8” BTP-370/A 8” In venting systems where a continuous or intermittent back (positive) draft is found to exist, the cause must be determined and corrected. In some cases, a special vent cap may be required. Do not install this unit on the positive draft side of a venting system being served by a power exhauster. water heater installation Water Line Connections Water Piping Diagrams This manual provides detailed water piping diagrams for typical methods of application for the water heaters, see Water Piping Diagrams beginning on page 35. The water piping installation must conform to these instructions and to all local code authority having jurisdiction. Good practice requires that all heavy piping be supported. The water heater may be installed by itself, or with a separate storage tank. When used with a separate storage tank, the circulation may be either by gravity or by means of circulating pump. Adjust flow by throttling a full port ball valve installed in the circulating line on the outlet side of the pump. Never throttle flow on the suction side of a pump. See the Water Piping Diagrams beginning on page 35. Read and observe all requirements in the following sections before installation of the water piping begins: 1. Water Temperature Control and Mixing Valves on page 13. 2. Dishwashing Machines on page 14. 3. Temperature-Pressure Relief Valve on page 14-15. 4. Closed Systems and Thermal Expansion on page 14. Note: In addition to the factory installed Temperature-Pressure Relief Valve (T&P valve) on the water heater, each remote storage tank that may be installed and piped to a water heating appliance must also have its own properly sized, rated and approved Temperature-Pressure Relief Valve installed. 5. For multiple water heater installations see Water Piping Diagrams beginning on page 35. Water (potable) Heating And Space Heating Call the toll free technical support phone number listed on the back cover of this manual for further assistance in sizing a T&P valve for remote storage tanks. 1. All piping components connected to this unit for space heating applications shall be suitable for use with potable water. T&P Valve Discharge Pipe 2. Toxic chemicals, such as those used for boiler treatment, shall NEVER be introduced into this system. 3. This unit may NEVER be connected to any existing heating system or component(s) previously used with a non-potable water heating appliance. Explosion Hazard 4. When the system requires water for space heating at temperatures higher than required for domestic water purposes, a tempering valve must be installed. Please refer to installation diagrams beginning on page 35 of this manual for suggested piping arrangements. Temperature-Pressure Relief Valve must comply with ANSI Z21.22CSA 4.4 and ASME code. 5. These water heaters cannot be used in space heating applications only Properly sized temperaturepressure relief valve must be installed in opening provided. Thermometers (not Supplied) Can result in overheating and excessive tank pressure. Thermometers should be obtained and field installed as shown in the installation diagrams. Can cause serious injury or death. Thermometers are installed in the system as a means of detecting the temperature of the outlet water supply. 19 Tube Inlet Installation This water heater is provided with a properly rated/sized and certified combination temperature - pressure (T&P) relief valve by the manufacturer. See Temperature-Pressure Relief Valve on pages 14-15 for information on replacement and other requirements. CAUTION Water Damage Hazard Figure 17. • Temperature-Pressure Relief Valve discharge pipe must terminate at adequate drain. BURNER INSTALLATION Remove the factory-installed insulation covering the combustion chamber opening. (A utility knife is useful for cutting out the insulation). Cut the insulation back even with the jacket opening. Install the flange gasket (which is usually taped to the heater jacket) over the three bolts protruding from the tank at the combustion chamber opening. Install a discharge pipe between the T&P valve discharge opening and a suitable floor drain. Do not connect discharge piping directly to the drain unless a 6” (15.2 cm) air gap is provided. To prevent bodily injury, hazard to life, or property damage, the relief valve must be allowed to discharge water in adequate quantities should circumstances demand. If the discharge pipe is not connected to a drain or other suitable means, the water flow may cause property damage. Remove hardware (3 hex nuts, 3 flat washers, and 3 lock washers) from the shipping bag attached to the heater’s electrical conduit. Begin assembling the power burner to the tank by placing the power burner nozzle in the combustion chamber opening. Slide the nozzle into the tank and rotate the mounting flange to engage the mounting bolts, refer to Figure 18. Then, place the flat washers followed by the lock washers, and finally the hex nuts on the mounting bolts. Hand tighten the nuts. Then gradually tighten each nut alternating between the 3 mounting bolts. Do not over tighten as damage to the flange gasket or to the tank may result. Refer to Figure 18. T&P Valve Discharge Pipe Requirements: • Shall not be smaller in size than the outlet pipe size of the valve, or have any reducing couplings or other restrictions. • Shall not be plugged or blocked. • Shall not be exposed to freezing temperatures. • Shall be of material listed for hot water distribution. • Shall be installed so as to allow complete drainage of both Temperature-Pressure Relief Valve and the discharge pipe. • Must terminate a maximum of six inches above a floor drain or external to the building. In cold climates, it is recommended that the discharge pipe be terminated at an adequate drain inside the building. • Shall not have any valve or other obstruction between the relief valve and the drain. Installation Diagrams - Top Inlet/Outlet Usage Use of the top inlet water connection requires an inlet dip tube (refer to Figure 17). The tube is supplied in the heater. Follow caution labels if applying heat to this fitting. Do not allow pipe dope to contact the plastic tube during installation. POWER BURNER INSTALLATION FIGURE 18. 20 heater wiring All electrical work must be installed in accordance with the current edition of the National Electrical Code ANSI/NFPA No. 70 or Canadian Electrical Code CSA C22.1 and must conform to all local code authority having jurisdiction. AN ELECTRICAL GROUND IS REQUIRED TO REDUCE RISK OF ELECTRICAL SHOCK OR POSSIBLE ELECTROCUTION. If any of the original wire as supplied with the water heater must be replaced, use only type 105°C thermoplastic or equivalent 2500C type F must be used for the flame sensor and igniter leads. The controls of this water heater are polarity sensitive. Be certain to properly wire the hot and neutral connections. Figure 19. 21 GAS PIPING Apply joint compounds (pipe dope) sparingly and only to the male threads of pipe joints. Do not apply compounds to the first two threads. Use compounds resistant to the action of liquefied petroleum gases. Contact your local gas service company to ensure that adequate gas service is available and to review applicable installation codes for your area. Gas Meter Size – Natural Gases Only Be sure the gas meter has sufficient capacity to supply the full rated gas input of the water heater as well as the requirements of all other gas fired equipment supplied by the meter. If gas meter is too small, ask the gas company to install a larger meter having adequate capacity. Size the main gas line in accordance with Table 8. The figures shown are for straight lengths of pipe at 0.5 in. W.C. pressure drop, which is considered normal for low pressure systems. Note: Fittings such as elbows, tees and line regulators will add to the pipe pressure drop. Also refer to the latest version of the National Fuel Gas Code. GAS PIPING AND SEDIMENT TRAP INSTALLATION Schedule 40 Steel or Wrought Iron Pipe is the preferred material for the gas line of this water heater. It is imperative to follow the sizing recommendations in the latest version of the National Fuel Gas Code if Corrugated Stainless Steel Tubing (CSST) is used as the gas line for this water heater. The heater is not intended for operation at higher than 14.0" W.C.natural gas, (1/2 pound per square inch gage) supply gas pressure. Exposure to higher supply pressure may cause damage to the gas valve which could result in fire or explosion. If overpressure has occurred such as through improper testing of gas lines or emergency malfunction of the supply system, the gas valve must be checked for safe operation. Make sure that the outside vents on the supply regulators and the safety vent valves are protected against blockage. These are parts of the gas supply system, not the heater. Vent blockage may occur during ice storms. Figure 20. Table 8. MAXIMUM CAPACITY OF PIPE IN CUBIC FEET OF GAS PER HOUR (Based upon a Pressure Drop of 0.5 inch Water Column and 0.6 Specific Gravity Gas and max. gas pressure of .5 psig) Gas Line Leak Testing NOMINAL IRON PIPE SIZE (INCHES) LENGTH IN FEET 1/2 3/4 1 10 175 360 680 20 120 250 465 30 97 200 40 82 170 1 1/4 1 1/2 2 2 1/2 3 4 Fire and Explosion Hazard 1,400 2,100 3,950 6,300 11,000 23,000 950 1,460 2,750 4,350 7,700 375 770 1,180 2,200 3,520 6.250 12.800 320 660 5,300 10,900 990 1,900 3,000 Use joint compound or Teflon tape compatible with propane gas. Leak test before placing the water heater in operation. Disconnect gas piping and main gas shutoff valve before leak testing. Install sediment trap in accordance with NFPA 54. 15,800 50 73 151 285 580 900 1,680 2,650 4,750 9,700 60 66 138 260 530 810 1,520 2,400 4,300 8,800 70 61 125 240 490 750 1,400 2,250 3,900 8,100 80 57 118 220 460 690 1,300 2,050 3,700 7,500 90 53 110 205 430 650 1,220 1,950 3,450 7,200 100 50 103 195 400 620 1,150 1,850 3,250 6,700 125 44 93 175 360 550 1,020 1,650 2,950 6,000 150 40 84 160 325 500 950 1,500 2,650 5,500 175 37 77 145 300 460 850 1,370 2,450 5,000 200 35 72 135 280 430 800 1,280 2,280 4,600 Any time work is done on the gas supply system perform a leak test to avoid the possibility of fire or explosion. 1.For test pressures exceeding 1/2 psi (3.45 kPa) disconnect the water heater and its Main Gas Shutoff Valve from the gas supply piping system during testing, see Figure 20. The gas supply line must be capped when disconnected from the water heater. 2.For test pressures of 1/2 psi (3.45 kpa) or less, the water heater need not be disconnected, but must be isolated from the supply gas line by closing the Main Gas Shutoff Valve during testing. It is important to guard against gas valve fouling from contaminants in gas ways. Such fouling may cause improper operation, fire or explosion. 3.Coat all supply gas line joints and connections upstream of the water heater with a non-corrosive soap and water solution to test for leaks. Bubbles indicate a gas leak. Do not use matches, candles, flame or other sources of ignition for this purpose. If copper supply lines are used they must be internally tinned and certified for gas service. Before attaching the gas line, be sure that all gas pipe is clean on the inside. 4.Repair any leaks before placing the water heater in operation. To trap any dirt or foreign material in the gas supply line, a sediment trap must be incorporated in the piping (see Figure 20). The sediment trap must be readily accessible and not subject to freezing conditions. Install in accordance with recommendations of serving gas suppliers. Refer to the latest version of the National Fuel Gas Code. Purging Gas line purging is required with new piping or systems in which air has entered. To prevent damage, care must be taken not to apply too much torque when attaching gas supply pipe to gas valve inlet. Purging should be performed per the current edition of NFPA 54 the National Fuel Gas Code. 22 START-UP and OPERATION • • • • • Fire or Explosion Hazard Gas line purging is required with new piping or systems in which air has entered. To avoid risk of fire or explosion purge discharge must not enter into confined areas or spaces where ignition can occur. The area must be well ventilated and all sources of ignition must be deactivated or removed. Attach a gas pressure gauge or manometer to upstream side of main gas cock and a gas pressure gauge or manometer to the manifold pressure tapping. Check voltage at disconnect switch to make certain that it matches that shown on the burner label. Apply a few drops of No. 20 SAE non-detergent oil to the motor bearings. Drill max. 5/16" hole in breeching as close as possible to flue connection on heater to install stack thermometer and combustion analyzing equipment. (See Figure 11). You are now ready to begin the burner start up procedure. Installation and start up of this water heater requires abilities and skills equivalent to that of a licensed tradesman in the field involved, see Qualifications on page 6. Do not place the water heater in operation if any part has been under water. Immediately call a qualified service technician to inspect the water heater and to replace any part of the control system and any gas control which has been under water. Read instruction manual before installing, using or servicing water heater. Light the water heater in accordance with the Lighting and Operation Instruction label on the water heater and in this manual on pages 25. Prior to Start Up Before attempting start up, thoroughly study and know the exact Sequence Of Operation. See written Sequence Of Operation on page 23 and Sequence Of Operation Flow Chart on page 24. This product requires a formal Start-Up by an authorized service/ start-up provider that has been approved by the manufacturer for this specific product. Call 1-800-527-1953 to locate the nearest authorized start-up provider and arrange a factory start-up. Please provide as much notice as possible, preferably 2 weeks. Please have the model and serial number ready when you call. This start-up is required to activate the warranty and ensure safe, efficient operation. Warranty on this product is limited and could be void in the event the unit is not installed per the instructions in this manual and/or not started up by an authorized factory trained service/start-up provider. The following test equipment should be on hand: (all test equipment must be acclimated to ambient temperature before calibration and use.) 1. CO2 indicator (Fyrite or similar) or O2 analyzer 2. CO indicator (Monoxor or similar) 3. Stack thermometer 4. Draft Gauge or inclined manometer 5. Two U-tube manometers or calibrated 0-10" and 0-35" w.c. pressure gauges. 6. Combination volt/ammeter. Be certain that the water heater is full of water, that air is purged from the gas and water lines and that there are no leaks in the gas and water lines. Ensure all inlet water valves are open. Filling The Water Heater Follow these steps to fill the water heater prior to start up. 1. Close the heater drain valve. 2. Open a nearby hot water faucet to permit air in system to escape. 3. Fully open the cold water inlet valve allowing the piping and water heater to fill with water. 4. Close hot water faucet opened in Step 2 as water starts to flow. Read SEQUENCE OF OPERATION section of this manual prior to lighting and operating this water heater. With above conditions satisfied, start the unit in accordance with the instructions on the operating label attached to the heater. For your convenience a copy of the instructions are shown on pages 25. SEQUENCE OF OPERATION 7. The following information will describe the Sequence of Operation for this water heater. 1. Switch power on to unit. 2. Thermostat calls for heat. 3. On a call for heat, 24V is applied to motor start relay and air switch. Once the fan motor reaches operating rpm combustion air pressure is sensed by the air proving switch and closes the switch contacts energizing the S89 ignition module. The ignition module performs diagnostic self check on system components. If the Ignition Control does not sense the flame during the 4 second ignition trial period, the Ignition Control shuts the Gas Valve and turns off the Spark Igniter. The control is locked out, the power to the unit must be cycled to restart the Ignition Control. 8. If the ignition control senses flame during the 4 seconds trial for ignition period, the gas control remains open and the burner on until the call for heat ends. 9. The Ignition Control monitors the Flame Sensor during the heating cycle. If the flame signal is lost, the Ignition Control shuts the Main Gas Valve and re-starts the ignition process at step 4. 4. The Ignition Control begins the trial for ignition after 30 seconds prepurge is completed. 5. The Ignition Control turns on the Spark Igniter and opens the Pilot Gas Valve. 10.Once the unit is satisfied, the Ignition Control will shut off the Main Gas Valve and the unit will be in standby mode until another call for heat is initiated by the thermostat. 6. The Ignition Control monitors the Flame Sensor during the ignition trial period. See the flow chart on page 26 for more information. 23 SEQUENCE OF OPERATION FLOW CHART Description of this flow chart can be found in the “SEQUENCE OF OPERATION” section found on page 25. START THERMOSTAT CALLS FOR HEAT. SAFE START CHECK POWER INTERUPTION. SYSTEM SHUTS OFF. RESTARTS WHEN POWER IS RESTORED. SAFE START CHECK IF FLAME SIMULATION CONDITION IS PRESENT, SYSTEM WILL NOT START. VALVE-ON DELAY (S89F ONLY) TRIAL FOR IGNITION BURNER OPERATION END VALVE-ON DELAY 30S PREPURGE COMBUSTION AIR BLOWER STARTS. SPARK GENERATOR POWERED, IGNITION BEGINS AND GAS CONTROL OPENS. IF NO SPARK, S89 LOCKS OUT AND SHUTS DOWN SYSTEM. MUST BE RESET. BURNER LIGHTS. IGNITION STOPS AND FLAME CURRENT IS SENSED. IF FLAME CURRENT IS ABSENT, WEAK, OR UNSTEADY, S89 LOCKS OUT AND SHUTS DOWN SYSTEM. MUST BE RESET. BURNER RUNS S89 MONITORS FLAME CURRENT. IF FLAME IS LOST, S89 CLOSES GAS CONTROL, THEN RESTARTS SAFE START CHECK AND TRIAL FOR IGNITION. THERMOSTAT SATISFIED. GAS CONTROL CLOSES, BURNER GOES OFF. FLOWCHART 1. 24 LIGHTING & OPERATION LABEL Figure 21. Label for Natural AND LP Gas Models 25 Adjustments time required for the heater to consume 5 cubic feet of gas. The actual rate may then be estimated by using the formula below: 1. Check gas line pressure and manifold pressure (table 10) and adjust as required. (3600/T) x H = Btuh 2. Check barometric damper for proper operation. Parts must move freely. T = Time in seconds to burn one cubic foot of gas. 3. Allow the unit to operate for 15 minutes. Drain hot water from the heater or storage tank to continue main burner operation. H = Btu’s per cubic foot of gas. Btuh = Actual heater input. Example: CHECKING VENTING T = 15.1 seconds The following steps shall be followed with each appliance connected to the venting system placed in operation, while any other appliances connected to the venting system are not in operation. H = 1050 Btu Btuh = ? (3600/15.1) x 1050 = 250,000 4. Determine heat input rate (see CHECKING THE INPUT section below). 1. Seal any unused openings in the venting system. 2. Inspect the venting system for proper size and horizontal pitch, as required in the National Fuel Gas Code, ANSI Z223.1or the CAN/CGA B149 Installation Codes and these instructions. Determine that there is no blockage or restriction, leakage, corrosion and other deficiencies which could cause an unsafe condition. The input may be adjusted by adjusting the pressure regulator. Remove the top cap to expose the adjustment screw. Turning the screw in increases the gas pressure and backing the screw out decreases the pressure. Do not turn the adjusting screw in past the point where no further increase in pressure is noted. 3. So far as is practical, close all building doors and windows and all doors between the space in which the water heater(s) connected to the venting system are located and other spaces of the building. Turn on all appliances not connected to the venting system. Turn on all exhaust fans, such as range hoods and bathroom exhausts, so they shall operate at maximum speed. Close fireplace dampers. The manifold pressure is measured at the manifold pressure tap, see figure 7, and should be used as a reference point for making pressure regulator adjustments. Table 6 gives the design manifold pressures for each model. Increase or reduce the pressure as required to obtain the rated input. If an acceptable rate cannot be achieved by adjusting the pressure regulator (manifold pressure), first check to be certain that the gas supply pressure to the unit is adequate. If the supply pressure is inadequate, a different burner orifice may be required. Obtain from the utility the heating value and specific gravity of the gas at the site. Provide this information and the altitude of the site to obtain a larger orifice size. 4. Follow the lighting instruction. Place the water heater in operation. Adjust thermostat so water heater shall operate continuously. 5. After it has been determined that each appliance connected to the venting system properly vents when tested as outlined above, return doors, windows, exhaust fans, fireplace dampers and any other gas burning appliance to their previous conditions of use. UNDER NO CIRCUMSTANCES SHOULD THE GAS INPUT EXCEED THE INPUT SHOWN ON THE HEATER MODEL AND RATING PLATE. OVERFIRING COULD RESULT IN DAMAGE OR SOOTING OF THE HEATER. 6. If improper venting is observed during any of the above tests, the venting system must be corrected. FAILURE TO CORRECT BACK DRAFTS MAY CAUSE AIR CONTAMINATION AND UNSAFE CONDITIONS. TABLE 9. APPROXIMATE TIME REQUIRED TO CONSUME 1 CU. FT. OF GAS AT FULL CAPACITY • If the back draft cannot be corrected by the normal method or if a suitable draft cannot be obtained, a blower type flue gas exhauster must be employed to assure proper venting and correct combustion. INPUT RATE (BTUH) INPUT BTUH PER CU. FT. TIMES (for Natural gas in Sec.) TIMES (for LP gas in Sec.) BTP-139 139000 1050 2500 27. 2 64.7 BTP-199 199000 1050 2500 19.0 45.2 The input rate can be estimated by timing the meter, if no other appliances are operating. BTP-270 270000 1050 2500 14.0 33.3 With a stopwatch, or a wristwatch, which can display the time in seconds, read the gas meter and measure the amount of BTP-370 370000 1050 2500 10.2. 24.3 CHECKING THE INPUT For installation locations with elevations above 2000 feet, refer to HIGH ALTITUDE INSTALLATIONS section of this manual for input reduction procedure. 26 SETTING BURNER OPERATION TABLE 10. NOMINAL START-UP SPECIFICATIONS Make combustion measurements and corresponding air shutter adjustments per table 10. Combustion results from table 10 are for natural gas models. MODEL Max. Gas Line Press.(W.C.) Manifold Press. (W.C.) Natural Gas Propane Gas Orifice Natural Gas Propane Gas Air Shutter Setting No. Natural Gas Propane Gas CO% CO Parts Per Million Gross Stack Temp. (°F) Breeching Press.(inches W.C.) • Proceed with CO2 test of the flue gases with an Orsat or other similar combustion test equipment. If the CO2 content is within range (see table 6) no adjustment of the air shutter is required. Flue gas temperature and CO2 measurements should be repeated 3 times to ensure accurate readings. • Check the flue gas temperature ahead of the barometric damper. See table 10 (net temp. = gross temp. = ambient temp.) • Check breeching pressure and the barometric damper control to make sure it operates freely and there is no discharge of flue products into the room. BTP BTP BTP BTP 139/A 199/A 270/A 370/A Nat. Gas - 10.5” W.C./Prop. Gas -13.0” 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 0.24 0.209 0.308 0.257 0.386 0.302 0.532 0.368 2.5 4.5 9.2% <200 305 5.75 10 9.8% <200 338 4 4 7.5% <200 405 3 8.5 8.0% <200 488 Ranges from - 0.02 to - 0.07 Inches Water Column • Check main burner operation by cycling on and off the thermostat dial several times. Wait 1 minute between cycles for regulators and sequencing to reset. When all adjustments are satisfactory: • Fill in part no. 196793 “Start-up” form. • Adjust thermostat temperature dial to deliver desired water temperature at point of use. • For subsequent normal starting and shutoff procedure, see LIGHTING and OPERATION LABEL on page 25. Figure 22. 27 mAINTENANCE venting system and BAROMETRIC DRAFT CONTROL heater where the thermostat senses the drop in water temperature and activates main burner operation of the water heater. The heater is equipped with a double acting barometric draft control. This control assembly is factory adjusted to automatically regulate the chimney draft imposed on the unit. The damper gate must pivot freely in the ring guides. See Figure 23. If the storage tank temperature control is out of calibration, replace with new control. SHOULD OVERHEATING OCCUR OR THE GAS SUPPLY FAIL TO SHUT OFF, TURN OFF THE MANUAL GAS CONTROL VALVE TO THE Water heater. temperature-Pressure relief Valve test Burn hazard. Hot water discharge. Keep clear of TemperaturePressure Relief Valve discharge outlet. BAROMETRIC DRAFT CONTROL FIGURE 23. Examine the venting system every six months for obstructions and/or deterioration of the vent piping. Remove all soot or other obstructions from chimney which will retard free draft. It is recommended that the Temperature-Pressure Relief Valve should be checked to ensure that it is in operating condition every 6 months. GENERAL When checking the Temperature-Pressure Relief Valve operation, make sure that (1) no one is in front of or around outlet of TemperaturePressure Relief Valve discharge line, and (2) that water discharge will not cause any property damage, as water may be extremely hot. Use care when operating valve as valve may be hot. Water heater maintenance includes periodic tank flushing and cleaning, and removal of lime scale. The power burner should be inspected and adjusted to maintain proper combustion. Refer to Table 10. A periodic inspection of the venting system and barometric damper should be made. Where used, the water heating system circulating pump should be oiled per manufacturer's instructions. To check the pressure relief valve, lift lever at the end of valve several times, see Figure 24. The valve should seat properly and operate freely. If after manually operating the valve, it fails to completely reset and continues to release water, immediately close the cold water inlet to the water heater and drain the water heater, see Draining And Flushing on page 32. Replace the Temperature-Pressure Relief Following are the instructions for performing some of the recommended maintenance. Power burner inspection and adjustment should be performed by a competent technician. TABLE 11. Valve with a properly rated/sized new one, see Temperature-Pressure Relief Valve on pages 12-13 for instructions on replacement. RECOMMENDED MAINTENANCE SCHEDULE FOR THE BTP HEATER COMPONENTS OPERATION INTERNAL Flushing Monthly Tank Sediments Removal Semi-Annually Lime Scale Removal As Required REQUIRED Un»l_ime Delimer Relief Valve Inspect Semi-Annually Circulating Pump and Power Burner Motor(1) Oiling Quarterly SAE No. 20 Non-Detergent Motor Oil Power Burner and Ignition Device (2) Inspection and Adjustment Semi-Annually Combustion Test Kit and Test Specifications Main Burner Vent System and Inspect Semi-Annually Barometric Damper Inspect Semi-Annually Anode(s) Inspect Annually Figure 24. If the Temperature-Pressure Relief Valve on water heater weeps or discharges periodically, this may be due to thermal expansion. NOTE: Excessive water pressure is the most common cause of Temperature-Pressure Relief Valve leakage. Excessive water system pressure is most often caused by "thermal expansion" in a "closed system." See Closed Water Systems and Thermal Expansion on page 12. The Temperature-Pressure Relief Valve is not intended for the constant relief of thermal expansion. Draft Gauge remote storage tank temperature control Water temperature in remote storage tank (if used) is controlled by the storage tank temperature control. The sensing element is mounted in the hot water storage tank, see Water Piping Diagram section. Temperature-Pressure Relief Valve leakage due to pressure build up in a closed system that does not have a thermal expansion tank installed is not covered under the limited warranty. Thermal expansion tanks must be installed on all closed water systems. A change in water temperature in the storage tank lower than the tank temperature control setting will cause the sensor to activate the circulating pump. The pump then circulates the water through the DO NOT PLUG THE TEMPERATURE-PRESSURE RELIEF VALVE OPENING. THIS CAN CAUSE PROPERTY DAMAGE, SERIOUS INJURY OR DEATH. 28 It is recommended that the water heater storage tank be drained and flushed every 6 months to reduce sediment buildup. The water heater should be drained if being shut down during freezing temperatures. See Features And Components in this manual for the location of the water heater components described below. TO DRAIN THE WATER HEATER STORAGE TANK: 1. Turn off the electrical supply to the water heater. 2. Turn off the gas supply at the Main Gas Shutoff Valve if the water heater is going to be shut down for an extended period. 3. Ensure the cold water inlet valve is open. 4. Open a nearby hot water faucet and let the water run until the water is no longer hot. 5. Close the cold water inlet valve to the water heater. 6. Connect a hose to the water heater drain valve and terminate it to an adequate drain. 7. Open the water heater drain valve and allow all the water to drain from the storage tank. 8. Close the water heater drain valve when all water in the storage tank has drained. 9. Close the hot water faucet opened in Step 4. 10.If the water heater is going to be shut down for an extended period, the drain valve should be left open. Explosion Hazard Temperature-Pressure Relief Valve must comply with ANSI Z21.22CSA 4.4 and ASME code. Properly sized temperaturepressure relief valve must be installed in opening provided. Can result in overheating and excessive tank pressure. Can cause serious injury or death. anode rod inspection CAUTION Property Damage Hazard TO FLUSH THE WATER HEATER STORAGE TANK: 1. Turn off the electrical supply to the water heater. 2. Ensure the cold water inlet valve is open. 3. Open a nearby hot water faucet and let the water run until the water is no longer hot. Then close the hot water faucet. 4. Connect a hose to the drain valve and terminate it to an adequate drain. 5. Ensure the drain hose is secured before and during the entire flushing procedure. Flushing is performed with system water pressure applied to the water heater. 6. Open the water heater drain valve to flush the storage tank. 7. Flush the water heater storage tank to remove sediment and allow the water to flow until it runs clean. 8. Close the water heater drain valve when flushing is completed. 9. Remove the drain hose. 10.Fill the water heater - see Filling The Water Heater in this manual. 11. Turn on electrical supply to place water heater back in operation. 12.Allow the water heater to complete several heating cycles to ensure it is operating properly. • Avoid water heater damage. • Inspection and replacement of anode rod required. The anode rod is used to protect the tank from corrosion. Most hot water tanks are equipped with an anode rod. The submerged rod sacrifices itself to protect the tank. Instead of corroding tank, water ions attack and eat away the anode rod. This does not affect water’s taste or color. The rod must be maintained to keep tank in operating condition. Anode rod deterioration depends on water conductivity, not necessarily water condition. A corroded or pitted anode rod indicates high water conductivity and should be checked and/or replaced more often than an anode rod that appears to be intact. Replacement of a depleted anode rod can extend the life of your water heater. Inspection should be conducted by a qualified technician, and at a minimum should be checked annually after warranty period. Artificially softened water is exceedingly corrosive because the process substitutes sodium ions for magnesium and calcium ions. Use of a water softener may decrease the life of water heater tank. recommended procedure for periodic removal of lime deposits from tank type commercial water heaters The anode rod should be inspected after a maximum of three years and annually thereafter until condition of anode rod dictates its replacement. Anode replacement is not covered by warranty. NOTE: artificially softened water requires the anode rod to be inspected annually. The amount of calcium carbonate (lime) released from water is in direct proportion to water temperature and usage, see chart. The higher the water temperature or water usage, the more lime deposits are dropped out of the water. This is the lime scale which forms in pipes, heaters and on cooking utensils. Lime accumulation not only reduces the life of equipment but also reduces efficiency of the heater and increases fuel consumption. The usage of water softening equipment greatly reduces the hardness of the water. However, this equipment does not always remove all of the hardness (lime). For this reason it is recommended that a regular schedule for deliming be maintained. The time between cleaning will vary from weeks to months depending upon water conditions and usage. The depth of lime buildup should be measured periodically. Heaters equipped with cleanouts will have about 2" of lime buildup when the level of lime has reached the bottom of the cleanout opening. A schedule for deliming should then be set up,based on the amount of time it would take for a 1" buildup of lime. It is recommended that the water heater initially be inspected after 6 months. Example 1: Initial inspection after 6 months shows 1/2" of lime accumulation. Therefore, the heater should be delimed once a year. Example 2: Initial inspection after 6 months shows 2" of lime accumulation. Therefore, the heater should be delimed every 3 months. Draining and flushing Burn harzard. Hot water discharge. Keep hands clear of drain valve discharge. 29 Prepare the Water Heater To delime the water heater using the Flo-Jug method, first prepare the heater for deliming. Explosion Hazard Flammable hydrogen gases may be present. Keep all ignition sources away from faucet when turning on hot water. Do not smoke or have open flame or sparks in vicinity of heater. Do not mix UN•LIME with other chemicals. Do not allow contact with magnesium, aluminum or galvanized metals. Figure 25. Chemical Hazard deliming solvents UN•LIME is recommended for deliming. UN•LIME is a patented food grade acid which is safe to handle and does not create the harmful fumes which are associated with other products. • Product contains phosphoric acid. • Keep out of reach of children. UN•LIME may be obtained from your dealer, distributor or water heater manufacturer. Order Part Number 9005416105, 1 gallon, packed 4 gallons per case or Part Number 9005417105, 5 gallon container. • Use rubber or neoprene gloves. Contains phosphoric acid. In case of external contact, flush with cool water. If irritation persists, get medical attention. If swallowed, give 1 or 2 glasses of water or milk and call physician. NOTE: Un•Lime is not available for use in Canada. Hydrochloric base acids are not recommended for use on glass lined tanks. Get immediate medical attention for eyes. Keep out of reach of children. Observe handling instructions on label of product being used. NOTE: THE USE OF RUBBER OR NEOPRENE GLOVES IS RECOMMENDED, ESPECIALLY IF YOU HAVE ANY OPEN SORES OR CUTS TO AVOID UNNECESSARY IRRITATION OR DISCOMFORT. tank Cleanout Procedure The following practices will ensure longer life and enable the unit to operate at its designed efficiency: 1. Once a month the heater should be flushed. Open drain valve and allow two gallons of water to drain from heater. Inlet water valve should remain open to maintain pressure in tank. 2. A cleanout opening is provided for periodic cleaning of the tank. Gas must be shut off and heater drained before opening cleanout. 1. Turn off fuel and/or power supply to heater. Also, turn off power to any electrical device or equipment, which is attached, or part of the system. 2. Open hot water side of faucet closest to heater and allow water to run until it is cool enough to handle safely. 3. Close cold water inlet valve to heater. 4. Connect hose to drain valve at bottom of heater and start draining heater into suitable floor drain area. 5. Remove pressure relief valve while heater is draining. NOTE: Do not replace pressure relief valve until deliming is completed. Pressure relief valve opening will also act as a vent in case of possible contact between the delimer and the anode rod(s), which may produce flammable hydrogen-air mixtures. 6. If pressure relief valve appears to be limed-up, place it in a clean glass or plastic container adequate in size so that you can pour enough UN•LIME® into container to cover the valve and allow space for foaming. When foaming stops, run fresh cool water into the container and rinse the pressure relief valve for a few minutes. 7. If heater does not drain completely after a reasonable length of time, turn off the main water supply valve to stop water from entering the tank due to a by-pass problem or defective cold water inlet valve. Also, check for clogged drain valve opening. Heater must be completely drained before introducing UN•LIME. 8. Remove the cleanout cover and place a clean plastic bucket next to the cleanout opening. Partially open the cold water inlet valve to allow time to accomplish the following and then close the valve. To clean heater through cleanout opening, proceed as follows: 3. Drain heater. 4. Remove outer cover plate from lower side of heater jacket. 5. Remove six (6) hex head screws securing tank cleanout plate and remove plate. 6. Remove lime, scale, or sediment using care not to damage the glass lining. 7. Inspect cleanout plate gasket, if new gasket is required, replace with part no. 9004099215. 8. Install cleanout plate. Be sure to draw plate up tight by tightening screws securely. 9. Replace outer jacket cover plate. In some water areas the sediment might not be removed by this method and may result in the water heater making rumbling or boiling noises. To dissolve and remove these more stubborn mineral deposits, UN•LIME Professional Delimer should be used. DELIMING USING FLO-JUG METHOD UN•LIME in the 5 gallon size is recommended for deliming of all models. Contact your local dealer, distributor or, water heater manufacturer: 30 While the water is being run through the tank, insert a stiff wire, copper tube flattened at one end or an opened wire coat hanger through the cleanout opening and scrape out any loose deposits of scale or sediment. This is an economical way to avoid unnecessary usage of the deliming solution. Normally, lime removal will be completed within one hour. Severe build-up of lime may take longer than an hour to complete descaling. Note: To check UN•LIME for continued use, place some scale or white chalk in a glass with a small amount of UN•LIME. If the material is vigorously dissolved by the UN•LIME, it can be reused; if not, the UN•LIME should be replaced. Repeat the opening and closing of the cold water inlet valve as necessary but be sure the heater is completely drained when ready to introduce the UN•LIME. Upon completion, reinstall the cleanout cover and use a new cleanout cover gasket (part number 9004099215). Remove the drain valve. 9. Install the long plastic male adapter insert fitting into the drain valve opening of heater after applying Teflon tape or paste to threads. Tighten firmly by hand and use wrench or adjustable pliers to check for secure connection. Do not over tighten to avoid damage to threads and fittings. Prepare the Up-N-Down Transfer Kit The next step is the preparation on the Up-N-Down Transfer Kit, if you have not already done so: 1. With the 5 gallon Up-N-Down container in the vertical position, unscrew the plastic vent cap in the handle and pierce the plastic membrane over the vent boss under the cap to allow the container to vent. Figure 26. power Burner Keep the area around the burner clear and free of combustible materials, gasoline or other flammable liquids or vapors. Do not obstruct burner air openings or ventilation grilles for combustion air. Note: If your container does not have the vent cap and vent boss, drill a 3/16” hole in the handle. When you have finished deliming you will be able to plug this drilled vent with the stainless steel screw that is supplied with the kit. 2. Remove the container’s cap and cut the plastic membrane located in the 3/4” IPT opening in the cap. Take care to not damage the threads. 3. Find the 3/4” male adapter, apply teflon tape to the threaded end and screw it into the 3/4” IPT opening in the cap. 4. Put cap with male adapter back on the container and slide 3/4” hose over end of male adapter and fasten in place using hose clamp provided. Delime using Flo-Jug Method 5. Slide the hose clamp over end of hose and slide hose over the male adapter in the water heater drain opening and secure in place using hose clamp. TYPICAL MAIN BURNER FLAME FIGURE 27. The main burner flames (Figure 27) should be visually checked once a year for proper operation. This can be observed through the observation port on the burner housing. Burner flame should be blue. DO NOT use the observation port on the side of the tank to inspect the burner flame. 6. Lift container to the “Pour” Position, see Figure 26, being careful to keep the vent in the handle above the liquid level and pour the UN•LIME into the heater. 7. Lower container, you may have to place the container on its empty carton to prevent the UN•LIME from flowing back into the container. 1. Add a few drops of no. 20 non-detergent oil (BTP-139/A thru 370/A) into the oil tubes once every three months. 2. At least annually, contact a qualified service agency for a burner readjustment, cleaning and other than routine maintenance. Should the main burner or burner air openings require cleaning, remove the burner and clean with a soft brush. Clean main burner orifice with a suitable soft material. 8. Let UN•LIME remain in the heater for 5 minutes and then lower the container to the “Drain” Position, see Figure 26. 9. Deliming activity is indicated by foaming on the surface of the UN•LIME. If there is deliming activity, repeat steps 6 thru 8. 31 Gas Control Valve Figure 30 shows the combination gas control valves used on these heaters. If gas control valve becomes defective, repairs should not be attempted. A new valve should be installed in place of defective one. Figure 30. SERVICE ELECTRICAL SERVICING The installer may be able to observe and correct certain problems which may arise when the unit is put into operation. HOWEVER, it is recommended that only a qualified service technician or qualified agencies, using appropriate test equipment, be allowed to service the heater. As preliminary step, check wiring against diagram, check for grounded, broken or loose wires. Check all wire ends to be sure that they are making good contact. LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICING CONTROLS. WIRING ERRORS CAN CAUSE IMPROPER AND DANGEROUS OPERATION. VERIFY PROPER OPERATION AFTER SERVICING. 32 Troubleshooting checklist COMPLAINT Water not hot enough. Insufficient hot water CAUSE USER REMEDY QUALIFIED SERVICE AGENCY Thermostat set too low. Set thermostat dial to a higher temperature. Upper and/or lower temperature probe out of calibration. Call qualified service agency. Thermostat set too low. Set thermostat dial to a higher temperature. Upper and/or lower temperature probe out of calibration. Call qualified service agency. Main manual gas shutoff valve partially closed. Open main manual gas shutoff valve to fullest extent. Heater too small for demand. Space usage to give heater time to restore water temperature. Heater recovery is slower. Call qualified service agency. Water temperature too hot. Thermostat set too high. Set thermostat to a lower setting. Heater makes sounds: sizzling. Condensation on outside of tank - normal. Rumbling. Sediment accumulation on bottom of tank. Ticking or metallic sounds. Expansion and contractionnormal. Pounding / water hammer. Air chambers in piping have become waterlogged. Thermal expansion tank damaged, improperly charged, or improperly sized. Combustion noises. Too much primary air. Overtired heater. Incorrect burners or orifice for types of gas used. Water leaks. Gas odors. Check continuity and resistance (Ohms) of upper and lower thermostat probes. Replace probes if out of specification. Check continuity and resistance (Ohms) of upper and lower thermostat probes. Replace probes if out of specification.. Check gas input. If incorrect, adjust gas pressure or replace main burner orifice. Drain a quantity of water through drain valve. If rumbling persists, call a qualified service agency. Delime heater. Drain piping system and refill. Heater must be off while this is being done. Check thermal expansion tank charge pressure when the water system pressure is zero. Follow the manufacturer's instructions for proper charging of the thermal expansion tank. Call qualified service agency. Call qualified service agency. Check and correct as necessary. Drain valve not closed tightly. If drain valve cannot be closed tightly, replace. If leakage source cannot be corrected or identified, call qualified service agency. Shut off gas supply to heater and close cold water inlet valve to heater. Repair or in case of suspected tank leakage, be certain to confirm before replacing heater. Heater is over fired. Shut off gas supply to heater and call qualified service agency. Check for sooted flue passage. Check for obstructed vent line. Check backdraft or lack of draft. Draft hood may be improperly installed or not sized properly. Possible gas leaks. Shut off gas supply to heater and call gas company at once. 33 For Your Information c. A sulfate reducing bacteria which has accumulated within the water heater (this harmless bacteria is nontoxic to humans). start up conditions SMOKE/ODOR d. An excess of active hydrogen in the tank. This is caused by the corrosion protective action of the anode rod. It is not uncommon to experience a small amount of smoke and odor during the initial start-up. This is due to burning off of oil from metal parts, and will disappear in a short while. Smelly water may be eliminated or reduced in some water heater models by replacing the anode rod(s) with one of less active material, and then chlorinating water heater tank and all water lines. STRANGE SOUNDS Possible noises due to expansion and contraction of some metal parts during periods of heat-up and cool-down do not necessarily represent harmful or dangerous conditions. Contact the local water heater supplier or service agency for further information concerning an Anode Rod Replacement Kit and this chlorination treatment. Condensation causes sizzling and popping within the burner area during heating and cooling periods and should be considered normal. See “Condensation" section in this manual. If smelly water persists after anode rod replacement and chlorination treatment, we can only suggest that chlorination or aeration of the water supply be considered to eliminate the water problem. CONDENSATION Whenever the water heater is filled with cold water, some condensate will form while the burner is on. A water heater may appear to be leaking when in fact the water is condensation. This usually happens when: Do not remove the anode rod leaving the tank unprotected. By doing so, all warranty on the water heater tank is voided. a. A new water heater is filled with cold water for the first time. HYDROGEN GAS: Hydrogen gas can be produced in a hot water system that has not been used for a long period of time (generally two weeks or more). Hydrogen gas is extremely flammable and explosive. To prevent the possibility of injury under these conditions, we recommend the hot water faucet, located farthest away, be opened for several minutes before any electrical appliances which are connected to the hot water system are used (such as a dishwasher or washing machine). If hydrogen gas is present, there will probably be an unusual sound similar to air escaping through the pipe as the hot water faucet is opened. There must be no smoking or open flame near the faucet at the time it is open. “AIR” IN HOT WATER FAUCETS b. Burning gas produces water vapor in water heaters, particularly high efficiency models where flue temperatures are lower. c. Large amounts of hot water are used in a short time and the refill water in the tank is very cold. Moisture from the products of combustion condense on the cooler tank surfaces and form drops of water which may fall onto the burner or other hot surfaces to produce a “sizzling” or “frying” noise. operational conditions HIGH WATER TEMPERATURE SHUT OFF SYSTEM HOT WATER ODOR This water heater is equipped with a manual reset type high limit (Energy Cutout) switch. The high limit switch interrupts the main burner gas flow should water temperature reach 203°F (95°C). In each water heater there is installed at least one anode rod for corrosion protection of the tank. Certain water conditions will cause a reaction between this rod and the water. The most common complaint associated with the anode rod is one of a “rotten egg smell” in the hot water. The smell is a result of four factors which must all be present for the odor to develop: In the event of high limit switch operation, the water heater cannot be restarted unless the water temperature is reduced to approximately 120F (49C). The high limit reset button on the front of the thermostat then needs to be depressed. See Figure 2 for the location of the reset button. a. A concentration of sulfate in the supply water. b. Little or no dissolved oxygen in the water. 34 35 ALT. COLD WATER CONNECTION HOT WATER TO FIXTURES NOTES: 1. Preferred piping diagram. 2. The temperature and pressure relief valve setting shall not exceed pressure rating of any component in the system. 3. Service valves are shown for servicing unit. However, local codes shall govern their usage. 4. The Tank Temperature Control should be wired to and control the pump between the water heater(s) and the storage tank(s). 5. The water heater’s operating thermostat should be set 5 degrees F higher than the Tank Temperature Control. FINISHED FLOOR PIPE T&P TO OPEN DRAIN WARNING: THIS DRAWING SHOWS SUGGESTED PIPING CONFIGURATION AND OTHER DEVICES; CHECK WITH LOCAL CODES AND ORDINANCES FOR ADDITIONAL REQUIREMENTS. MULTI FLUE - (1 UNIT) WITH VERTICAL STORAGE TANK COLD WATER SUPPLY EXPANSION TANK DRAIN WATER FLOW SWITCH TEMPERATURE GAGE CHECK VALVE FULL PORT BALL VALVE HOT WATER RETURN FROM FIXTURES TANK TEMPERATURE CONTROL CIRCULATING PUMP PRESSURE RELIEF VALVE TEMPERATURE & PRESSURE RELIEF VALVE LEGEND water Piping Diagrams 36 HOT WATER TO FIXTURES ALTERNATE LOCATION NOTES: 1. Preferred piping diagram. 2. The temperature and pressure relief valve setting shall not exceed pressure rating of any component in the system. 3. Service valves are shown for servicing unit. However, local codes shall govern their usage. 4. The Tank Temperature Control should be wired to and control the pump between the water heater(s) and the storage tank(s). 5. The water heater’s operating thermostat should be set 5 degrees F higher than the Tank Temperature Control. FINISHED FLOOR PIPE T&P TO OPEN DRAIN WARNING: THIS DRAWING SHOWS SUGGESTED PIPING CONFIGURATION AND OTHER DEVICES; CHECK WITH LOCAL CODES AND ORDINANCES FOR ADDITIONAL REQUIREMENTS. MULTI FLUE - (1 UNIT) WITH HORIZONTAL STORAGE TANK DRAIN WATER FLOW SWITCH TEMPERATURE GAGE CHECK VALVE FULL PORT BALL VALVE EXPANSION TANK COLD WATER SUPPLY HOT WATER RETURN FROM FIXTURES CIRCULATING PUMP TANK TEMPERATURE CONTROL CIRCULATING PUMP PRESSURE RELIEF VALVE TEMPERATURE & PRESSURE RELIEF VALVE LEGEND 37 HOT WATER RETURN TEMPERED WATER OUTLET COLD HOT HOT WATER OUTLET NOTES: 1. Preferred piping diagram. 2. The temperature and pressure relief valve setting shall not exceed pressure rating of any component in the system. 3. Service valves are shown for servicing unit. However, local codes shall govern their usage. 4. The Tank Temperature Control should be wired to and control the pump between the water heater(s) and the storage tank(s). EXPANSION TANK COLD WATER SUPPLY TEMPERED WATER RETURN WARNING: THIS DRAWING SHOWS SUGGESTED PIPING CONFIGURATION AND OTHER DEVICES; CHECK WITH LOCAL CODES AND ORDINANCES FOR ADDITIONAL REQUIREMENTS. MULTI FLUE - (1 UNIT) WITH MIXING VALVE TWO TEMPERATURE DRAIN PIPE T&P TO OPEN DRAIN TANK TEMPERATURE CONTROL CIRCULATING PUMP PRESSURE RELIEF VALVE TEMPERATURE & PRESSURE RELIEF VALVE LEGEND WATER FLOW SWITCH TEMPERATURE GAGE CHECK VALVE FULL PORT BALL VALVE 38 PIPE T&P TO OPEN DRAIN NOTES: 1. Preferred piping diagram. 2. The temperature and pressure relief valve setting shall not exceed pressure rating of any component in the system. 3. Service valves are shown for servicing unit. However, local codes shall govern their usage. 4. The Tank Temperature Control should be wired to and control the pump between the water heater(s) and the storage tank(s). PIPE T&P TO OPEN DRAIN HOT WATER TO FIXTURES WARNING: THIS DRAWING SHOWS SUGGESTED PIPING CONFIGURATION AND OTHER DEVICES; CHECK WITH LOCAL CODES AND ORDINANCES FOR ADDITIONAL REQUIREMENTS. MULTI FLUE - (2 UNITS) COLD WATER SUPPLY EXPANSION TANK DRAIN TANK TEMPERATURE CONTROL CIRCULATING PUMP PRESSURE RELIEF VALVE TEMPERATURE & PRESSURE RELIEF VALVE WATER FLOW SWITCH TEMPERATURE GAGE CHECK VALVE FULL PORT BALL VALVE HOT WATER RETURN LEGEND 39 PIPE T&P TO OPEN DRAIN NOTES: 1. Preferred piping diagram. 2. The temperature and pressure relief valve setting shall not exceed pressure rating of any component in the system. 3. Service valves are shown for servicing unit. However, local codes shall govern their usage. 4. The Tank Temperature Control should be wired to and control the pump between the water heater(s) and the storage tank(s). 5. The water heater’s operating thermostat should be set 5 degrees F higher than the Tank Temperature Control. FINISHED FLOOR PIPE T&P TO OPEN DRAIN WARNING: THIS DRAWING SHOWS SUGGESTED PIPING CONFIGURATION AND OTHER DEVICES; CHECK WITH LOCAL CODES AND ORDINANCES FOR ADDITIONAL REQUIREMENTS. MULTI FLUE - (2 UNITS) WITH VERTICAL STORAGE TANK ALTERNATE COLD WATER CONNECTION HOT WATER TO FIXTURES DRAIN TANK TEMPERATURE CONTROL CIRCULATING PUMP PRESSURE RELIEF VALVE TEMPERATURE & PRESSURE RELIEF VALVE COLD WATER SUPPLY HOT WATER RETURN WATER FLOW SWITCH TEMPERATURE GAGE CHECK VALVE FULL PORT BALL VALVE EXPANSION TANK LEGEND 40 PIPE T&P TO OPEN DRAIN NOTES: 1. Preferred piping diagram. 2. The temperature and pressure relief valve setting shall not exceed pressure rating of any component in the system. 3. Service valves are shown for servicing unit. However, local codes shall govern their usage. 4. The Tank Temperature Control should be wired to and control the pump between the water heater(s) and the storage tank(s). 5. The water heater’s operating thermostat should be set 5 degrees F higher than the Tank Temperature Control. FINISHED FLOOR PIPE T&P TO OPEN DRAIN WARNING: THIS DRAWING SHOWS SUGGESTED PIPING CONFIGURATION AND OTHER DEVICES; CHECK WITH LOCAL CODES AND ORDINANCES FOR ADDITIONAL REQUIREMENTS. MULTI FLUE - (2 UNITS) WITH VERTICAL STORAGE TANK ALTERNATE COLD WATER CONNECTION HOT WATER TO FIXTURES DRAIN TANK TEMPERATURE CONTROL CIRCULATING PUMP PRESSURE RELIEF VALVE TEMPERATURE & PRESSURE RELIEF VALVE COLD WATER SUPPLY HOT WATER RETURN WATER FLOW SWITCH TEMPERATURE GAGE CHECK VALVE FULL PORT BALL VALVE EXPANSION TANK LEGEND 41 PIPE T&P TO OPEN DRAIN HOT WATER TO FIXTURES DRAIN EXPANSION TANK COLD WATER SUPPLY TANK TEMPERATURE CONTROL CIRCULATING PUMP PRESSURE RELIEF VALVE TEMPERATURE & PRESSURE RELIEF VALVE ALTERNATE LOCATION NOTES: 1. Preferred piping diagram. 2. The temperature and pressure relief valve setting shall not exceed pressure rating of any component in the system. 3. Service valves are shown for servicing unit. However, local codes shall govern their usage. 4. The Tank Temperature Control should be wired to and control the pump between the water heater(s) and the storage tank(s). 5. The water heater’s operating thermostat should be set 5 degrees F higher than the Tank Temperature Control. FINISHED FLOOR PIPE T&P TO OPEN DRAIN WARNING: THIS DRAWING SHOWS SUGGESTED PIPING CONFIGURATION AND OTHER DEVICES; CHECK WITH LOCAL CODES AND ORDINANCES FOR ADDITIONAL REQUIREMENTS. MULTI FLUE - (2 UNITS) WITH HORIZONTAL STORAGE TANK LEGEND HOT WATER RETURN FROM FIXTURES WATER FLOW SWITCH TEMPERATURE GAGE CHECK VALVE FULL PORT BALL VALVE 42 EXPANSION TANK COLD WATER SUPPLY HOT WATER RETURN HOT WATER TO FIXTURES PRE-HEATED WATER TO BOOSTER DRAIN BOOSTER HEATER WATER FLOW SWITCH TEMPERATURE GAGE CHECK VALVE FULL PORT BALL VALVE BOOSTER WATER RETURN TANK TEMPERATURE CONTROL CIRCULATING PUMP PRESSURE RELIEF VALVE TEMPERATURE & PRESSURE RELIEF VALVE BOOSTER WATER TO FIXTURES NOTES: 1. Preferred piping diagram. 2. The temperature and pressure relief valve setting shall not exceed pressure rating of any component in the system. 3. Service valves are shown for servicing unit. However, local codes shall govern their usage. 1st HEATER WARNING: THIS DRAWING SHOWS SUGGESTED PIPING CONFIGURATION AND OTHER DEVICES; CHECK WITH LOCAL CODES AND ORDINANCES FOR ADDITIONAL REQUIREMENTS. MULTI FLUE (2 UNITS) TWO TEMPERATURE LEGEND 43 PRE-HEATER PRE-HEATER MUST BE IDENTICAL HEATERS PIPE T&P TO OPEN DRAIN DRAIN BOOSTER RETURN (IF USED) EXPANSION TANK COLD WATER SUPPLY TANK TEMPERATURE CONTROL CIRCULATING PUMP PRESSURE RELIEF VALVE TEMPERATURE & PRESSURE RELIEF VALVE HOT OUTLET AT STORED TEMPERATURE BOOSTED WATER OUTLET TYPICAL BOOSTER HEATER PIPE T&P TO OPEN DRAIN NOTES: 1. Preferred piping diagram. 2. The temperature and pressure relief valve setting shall not exceed pressure rating of any component in the system. 3. Service valves are shown for servicing unit. However, local codes shall govern their usage. FINISHED FLOOR PIPE T&P TO OPEN DRAIN WARNING: THIS DRAWING SHOWS SUGGESTED PIPING CONFIGURATION AND OTHER DEVICES; CHECK WITH LOCAL CODES AND ORDINANCES FOR ADDITIONAL REQUIREMENTS. MULTI FLUE (2 UNITS) WITH BOOSTER TWO TEMPERATURE LEGEND HOT WATER RETURN WATER FLOW SWITCH TEMPERATURE GAGE CHECK VALVE FULL PORT BALL VALVE 44 PIPE T&P TO OPEN DRAIN PIPE T&P TO OPEN DRAIN NOTES: 1. Preferred piping diagram. 2. The temperature and pressure relief valve setting shall not exceed pressure rating of any component in the system. 3. Service valves are shown for servicing unit. However, local codes shall govern their usage. PIPE T&P TO OPEN DRAIN HOT WATER TO FIXTURES WARNING: THIS DRAWING SHOWS SUGGESTED PIPING CONFIGURATION AND OTHER DEVICES; CHECK WITH LOCAL CODES AND ORDINANCES FOR ADDITIONAL REQUIREMENTS. MULTI-FLUE (3 UNITS) DRAIN EXPANSION TANK COLD WATER SUPPLY TANK TEMPERATURE CONTROL CIRCULATING PUMP PRESSURE RELIEF VALVE TEMPERATURE & PRESSURE RELIEF VALVE LEGEND HOT WATER RETURN WATER FLOW SWITCH TEMPERATURE GAGE CHECK VALVE FULL PORT BALL VALVE 45 PIPE T&P TO OPEN DRAIN HEATER PIPE T&P TO OPEN DRAIN HEATER PIPE T&P TO OPEN DRAIN DRAIN TANK TEMPERATURE CONTROL CIRCULATING PUMP PRESSURE RELIEF VALVE ALT. COLD WATER CONNECTION EXPANSION TANK HOT WATER RETURN WATER FLOW SWITCH TEMPERATURE GAGE CHECK VALVE FULL PORT BALL VALVE COLD WATER SUPPLY LEGEND TEMPERATURE & PRESSURE RELIEF VALVE HOT WATER TO FIXTURES NOTES: 1. Preferred piping diagram. 2. The temperature and pressure relief valve setting shall not exceed pressure rating of any component in the system. 3. Service valves are shown for servicing unit. However, local codes shall govern their usage. 4. The Tank Temperature Control should be wired to and control the pump between the water heater(s) and the storage tank(s). 5. The water heater’s operating thermostat should be set 5 degrees F higher than the Tank Temperature Control. FINISHED FLOOR PIPE T&P TO OPEN DRAIN HEATER WARNING: THIS DRAWING SHOWS SUGGESTED PIPING CONFIGURATION AND OTHER DEVICES; CHECK WITH LOCAL CODES AND ORDINANCES FOR ADDITIONAL REQUIREMENTS. MULTI-FLUE (3 UNITS) WITH VERTICAL STORAGE TANK AOS STORAGE TANK 46 HEATER PIPE T&P TO OPEN DRAIN HEATER PIPE T&P TO OPEN DRAIN HEATER AOS STORAGE TANK HOT WATER TO FIXTURES NOTES: 1. Preferred piping diagram. 2. The temperature and pressure relief valve setting shall not exceed pressure rating of any component in the system. 3. Service valves are shown for servicing unit. However, local codes shall govern their usage. 4. The Tank Temperature Control should be wired to and control the pump between the water heater(s) and the storage tank(s). 5. The water heater’s operating thermostat should be set 5 degrees F higher than the Tank Temperature Control. FINISHED FLOOR PIPE T&P TO OPEN DRAIN WARNING: THIS DRAWING SHOWS SUGGESTED PIPING CONFIGURATION AND OTHER DEVICES; CHECK WITH LOCAL CODES AND ORDINANCES FOR ADDITIONAL REQUIREMENTS. MULTI-FLUE (3 UNITS) WITH HORIZONTAL STORAGE TANK ALTERNATE LOCATION PIPE T&P TO OPEN DRAIN DRAIN TANK TEMPERATURE CONTROL CIRCULATING PUMP PRESSURE RELIEF VALVE TEMPERATURE & PRESSURE RELIEF VALVE LEGEND EXPANSION TANK COLD WATER SUPPLY HOT WATER RETURN WATER FLOW SWITCH TEMPERATURE GAGE CHECK VALVE FULL PORT BALL VALVE 47 PIPE T&P TO OPEN DRAIN PIPE T&P TO OPEN DRAIN PIPE T&P TO OPEN DRAIN NOTES: 1. Preferred piping diagram. 2. The temperature and pressure relief valve setting shall not exceed pressure rating of any component in the system. 3. Service valves are shown for servicing unit. However, local codes shall govern their usage. FINISHED FLOOR HOT WATER TO FIXTURES WARNING: THIS DRAWING SHOWS SUGGESTED PIPING CONFIGURATION AND OTHER DEVICES; CHECK WITH LOCAL CODES AND ORDINANCES FOR ADDITIONAL REQUIREMENTS. MULTI FLUE FLUE (4 UNITS) PIPE T&P TO OPEN DRAIN DRAIN HOT WATER RETURN WATER FLOW SWITCH TEMPERATURE GAGE CHECK VALVE FULL PORT BALL VALVE COLD WATER SUPPLY EXPANSION TANK TANK TEMPERATURE CONTROL CIRCULATING PUMP PRESSURE RELIEF VALVE TEMPERATURE & PRESSURE RELIEF VALVE LEGEND 48 HEATER HEATER PIPE T&P TO OPEN DRAIN HEATER PIPE T&P TO OPEN DRAIN PIPE T&P TO OPEN DRAIN NOTES: 1. Preferred piping diagram. 2. The temperature and pressure relief valve setting shall not exceed pressure rating of any component in the system. 3. Service valves are shown for servicing unit. However, local codes shall govern their usage. 4. The Tank Temperature Control should be wired to and control the pump between the water heater(s) and the storage tank(s). 5. The water heater’s operating thermostat should be set 5 degrees F higher than the Tank Temperature Control. FINISHED FLOOR PIPE T&P TO OPEN DRAIN HEATER PIPE T&P TO OPEN DRAIN WARNING: THIS DRAWING SHOWS SUGGESTED PIPING CONFIGURATION AND OTHER DEVICES; CHECK WITH LOCAL CODES AND ORDINANCES FOR ADDITIONAL REQUIREMENTS. MULTI-FLUE (4 UNITS) WITH VERTICAL STORAGE TANK AOS STORAGE TANK ALT. COLD WATER CONNECTION HOT WATER TO FIXTURES DRAIN WATER FLOW SWITCH TEMPERATURE GAGE CHECK VALVE FULL PORT BALL VALVE EXPANSION TANK COLD WATER SUPPLY HOT WATER RETURN TANK TEMPERATURE CONTROL CIRCULATING PUMP PRESSURE RELIEF VALVE TEMPERATURE & PRESSURE RELIEF VALVE LEGEND 49 HEATER HEATER PIPE T&P TO OPEN DRAIN HEATER PIPE T&P TO OPEN DRAIN DRAIN AOS STORAGE TANK ALTERNATE LOCATION PIPE T&P TO OPEN DRAIN TANK TEMPERATURE CONTROL CIRCULATING PUMP PRESSURE RELIEF VALVE TEMPERATURE & PRESSURE RELIEF VALVE HOT WATER TO FIXTURES NOTES: 1. Preferred piping diagram. 2. The temperature and pressure relief valve setting shall not exceed pressure rating of any component in the system. 3. Service valves are shown for servicing unit. However, local codes shall govern their usage. 4. The Tank Temperature Control should be wired to and control the pump between the water heater(s) and the storage tank(s). 5. The water heater’s operating thermostat should be set 5 degrees F higher than the Tank Temperature Control. FINISHED FLOOR PIPE T&P TO OPEN DRAIN HEATER PIPE T&P TO OPEN DRAIN WARNING: THIS DRAWING SHOWS SUGGESTED PIPING CONFIGURATION AND OTHER DEVICES; CHECK WITH LOCAL CODES AND ORDINANCES FOR ADDITIONAL REQUIREMENTS. MULTI-FLUE (4 UNITS) WITH HORIZONTAL STORAGE TANK LEGEND EXPANSION TANK COLD WATER SUPPLY HOT WATER RETURN WATER FLOW SWITCH TEMPERATURE GAGE CHECK VALVE FULL PORT BALL VALVE manifold kits Dimensions shown are for minimum space occupied by the water heaters assemblies. Space for the barometric draft control assemblies, combustion clearances and servicing must be added. PRIOR TO START UP IMPORTANT Factory Start-Up is required for activating warranty and assuring maximum operating performance. Contact your local sales representatives or Authorized Start-Up Agent to arrange a FREE Certified Start-Up. 50 COMMERCIAL GAS Glass Lined Tank Type Water Heater REPLACEMENT PARTS LIST MAIN BURNER ORIFICE CHART Natural Gas Propane Gas BurnerWayne C.S.Wayne C.S. ModelsNumber Part No. (Decimal) Part No. (Decimal) BTP-139 HSG-200 62459-001 0.24 62459-001 0.209 BTP-199 HSG-200 62459-001 0.38 62459-001 0.257 BTP-270(A) HSG-400 62459-002 0.368 62459-002 0.302 BTP-370(A) HSG-400 62459-002 0.532 62459-002 0.386 51 ItemDescription BTP-139 BTP-199 BTP-270, 270A BTP-370, 370A 1..... Anode........................................................9003892005(2)........ 9003892005(2).......9003892005(2)...........9003892005(2) 2..... Baffle, Flue.................................................9005293205(7)........ 9005293205(7).......9005293205(7)...........9005293205(7) 3..... Barometric Draft Control w Tee Assy.........9500007199............ 9500007199............9500007200...............9500007200 Cleanout Assembly: 4..... Gasket.......................................................9004099215............ 9004099215............9004099215...............9004099215 5..... Pressure Plate...........................................9005797205............ 9005797205............9005797205...............9005797205 6..... Screw, Self Tapping (Req’d)......................9004100215............ 9004100215............9004100215...............9004100215 7..... Cover, Cleanout Opening..........................181260.................... 181260....................181260.......................181260 8..... Thermostat with ECO................................9004529005............ 9004529005............9004529005...............9004529005 9..... Valve, Drain...............................................9003906015............ 9003906015............9003906015...............9003906015 10.... Valve, T & P...............................................9005903205............ 9005903205............9005903205...............9005903205 11.... Reducer, Flue............................................76707-0................... 76707-0...................76707-4......................76707-4 * Items not illustrated. ( ) Reflects quantities. All information such as model and series number, type of gas and specifications must tobe supplied to State Water Heaters. 52 notes 53 notes 54 Model BTP Limited Warranty Factory Start-Up is required for activating warranty and assuring maximum operating performance. Contact your local sales representatives or Authorized StartUp Agent to arrange a FREE Certified Start-Up. A. O. Smith Corporation, the warrantor, extends the following LIMITED WARRANTY to the owner of this water heater. 1.THE TANK If the glass-lined tank in this water heater shall prove upon examination by the warrantor to have leaked due to natural corrosion from potable water therein, during the first THREE years after initial installation, the warrantor will supply a complete new A. O. Smith water heater of equivalent size and current model. Some government agencies are requiring energy efficient standards for water heaters. In the event regulations prohibit sale of a model of equivalent size and construction, A. O. Smith will provide a model which complies with the regulations of your area, in which case the consumer will be charged the difference in price between the like replacement and the energy efficient model required. The warranty on the replacement water heater will be limited to the unexpired term of the original warranty. 2.ALL OTHER PARTS If within ONE year after initial installation of this water heater, any part or portion shall prove upon examination by the warrantor to be defective in material or workmanship, the warrantor will repair or replace such part or portion at its option. 3.CONDITIONS AND EXCEPTIONS This warranty shall apply only when the water heater is installed in accordance with local plumbing and building codes, ordinances and regulations, the printed instructions provided with it and good industry practices. In addition, a temperature and pressure relief valve, certified by A.G.A. and approved by the American Society of Mechanical Engineers, must have been installed. a. This warranty shall apply only when the heater is used: (1) at temperatures not exceeding the maximum setting of its thermostat; (2) at water pressure not exceeding the working pressure shown on the water heater; (3)when operated free of the damaging effects of uncontrolled water hammer; (4) when filled with potable water, free to circulate at all times; (5) in a non-corrosive and non-contaminated atmosphere; (6) in its original installation location; (7) with factory approved anode(s) installed; (8) in the United States, its territories or possessions, and Canada. b. Any accident to the water heater, any misuse, abuse (including freezing) or alteration of it, any operation of it in a modified form, or any attempt to repair tank leaks will void this warranty. c. This warranty is void if a device acting as a backflow prevention device (check valves etc.) is installed in the cold water supply the heater is connected to, unless an effective method of controlling thermal expansion is also installed at the heater(s) and operational at all times. The relief valve installed on the heater is not an acceptable method. 4.SERVICE AND REPAIR EXPENSES Under the limited warranty the warrantor will provide only a replacement water heater or part thereof. The owner is responsible for all other costs. Such costs may include but are not limited to: a. Labor charges for service removal, repair or reinstallation of the water heater or any component part; b. Shipping, delivery, handling, and administrative charges for forwarding the new heater or replacement part from the nearest distributor and returning the claimed defective heater or part to such distributor. c. All cost necessary or incidental for any material and/or permits required for installation of the replacement heater or part. 5.LIMITATIONS ON IMPLIED WARRANTIES Implied warranties, including the warranty of merchantability imposed on the sale of this heater under state law are limited to one (1) year duration for the heater or any of its parts. Some states do not allow limitation on how long an implied warranty lasts, so the above limitation may not apply to you. 6.CLAIM PROCEDURE Any claim under the warranty should be initiated with the dealer who sold the heater, or with any other dealer handling the warrantor’s products. If this is not practicable, the owner should contact: U.S. Customers Canadian Customers A. O. Smith Corporation A. O. Smith Enterprises Ltd. 500 Tennessee Waltz Parkway P. O. Box, 310 - 768 Erie Street Ashland City, TN 37015Stratford, Ontario N5A 6T3 Telephone: 1-(800) 527-1953 Telephone: 1-(800) 265-8520 a. The warrantor will only honor replacement with identical or similar water heater or parts thereof which are manufactured or distributed by the warrantor. b. Dealer replacements are made subject to in-warranty validation by warrantor. 7.DISCLAIMERS NO OTHER EXPRESS WARRANTY HAS BEEN OR WILL BE MADE IN BEHALF OF THE WARRANTOR WITH RESPECT TO THE HEATER OR THE INSTALLATION, OPERATION, REPAIR OR REPLACEMENT OF THE HEATER. THE WARRANTOR SHALL NOT BE RESPONSIBLE FOR WATER DAMAGE, LOSS OF USE OF THE UNIT, INCONVENIENCE, LOSS OR DAMAGE TO PERSONAL PROPERTY OR OTHER CONSEQUENTIAL DAMAGE. THE WARRANTOR SHALL NOT BE LIABLE BY VIRTUE OF THIS WARRANTY OR OTHERWISE FOR DAMAGE TO ANY PERSONS OR PROPERTY, WHETHER DIRECT OR INDIRECT, AND WHETHER ARISING IN CONTRACT OR IN TORT. a. Some states do not allow the exclusion or limitation of the incidental or consequential damage, so the above limitations or exclusions may not apply to you. b. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. Fill in the following for your own reference. Keep it. Registration is not a condition of warranty. The model and serial number are found on the heater’s rating plate. Model No.______________________ Serial No.________________________________________________ Date Installed___________________________ Dealer’s Name_________________________________________________________________________________________________________________ Dealer’s Address______________________________________________________________________________ Phone No._________________________ City and State__________________________________________________________________________________ Zip____________________________ KEEP THIS WARRANTY POSTED ADJACENT TO THE HEATER FOR FUTURE REFERENCE. 55 500 Tennessee Waltz Parkway, Ashland City, TN 37015 Technical Support: 800-527-1953 • Parts: 800-433-2545 www.hotwater.com Copyright © 2012 A. O. Smith, All rights reserved.
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement