VXP21/22/23 Series Pilot Operated 2 Port Solenoid Valve

VXP21/22/23 Series Pilot Operated 2 Port Solenoid Valve
Pilot Operated 2 Port Solenoid Valve
Series VXP21/22/23
For Air, Gas, Steam, Water and Oil
쐽 Wide variations of combination.
Able to control a wide variety of fluids.
VX2
VXD
Valve can be matched to particular application through selection of
body materials (Brass (C37)/BC6 or Stainless steel), seal material
(NBR, PTFE, EPDM or FKM) and solenoid coil (Class B or H).
VXZ
쐽 Easy to disassemble and reassemble in a short
time.
쐽 Flange for threaded ports available.
VXE
VXP
(32A to 50A)
N.C.
VXR
VXH
VXF
VX3
VXA
N.O.
VCH첸
Variations
VDW
VQ
Valve 앬
OUT
Normally closed
(N.C.)
IN
OUT
Normally open
(N.O.)
Rated voltage 앬
100 V, 200 V
48 V, 110 V, 220 V, 240 V
24 V
12 V
Material 앬
Body
Seal
VCA
VCB
VCL
Model
Model
Coil: Class B, Class H
Standard
Option
쏔DC
Standard
Option
LVM
• Grommet
• Conduit
• DIN terminal
• Conduit terminal
IN
Solenoid coil 앬
쏔AC
앬 Electrical entry
Brass (C37)/BC6, Stainless steel
NBR, FKM, EPDM, PTFE
Port size
Threaded type
VXP2130 Rc 1 4, 3 8, 1 2
VXP214 20 Rc 3 8, 1 2
VXP215 20
Rc 3 4
VXP226 20
Rc 1
VXP227 20
Rc 11 4
2
VXP238 0
Rc 11 2
2
VXP239 0
Rc 2
Flange type
VXP227 20
32A
VXP238 20
40A
VXP239 20
50A
Orifice dia.
(mmø)
VCS
VCW
10
15
20
25
35
40
50
35
40
50
145
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Applicable Fluids Check List
Pilot Operated 2 Port Solenoid Valve Series VXP21/22/23
Normally Closed (N.C.)
Refer to page 147 for specifications and models.
Option Symbol and Composition
Option symbol
Seal material
Standard
A
B
C Note 2)
D
E
F Note 1)
G
H
J
K Note 2)
L Note 1)
N
P
Q Note 2)
S Note 2)
T Note 1)
NBR
FKM
EPDM
PTFE
FKM
EPDM
FKM
NBR
FKM
EPDM
PTFE
FKM
FKM
EPDM
PTFE(FKM)
PTFE(FKM)
NBR
Fluid Name and Option
Coil insulation
type
Body, Shading
coil material
B
Brass (C37) or BC6, Copper
H
B
Stainless steel, Silver
(10 to 25 A)
Not available for 32 A to 50 A
H
Brass (C37) or BC6, Copper
B
Note 1) Non-lube type. For other options, “-X21” at the end of product number represents the
non-lube option.
Note 2) Available option for VXP2130.
Option symbol and body material
Brass (C37) or BC6 Stainless steel
Applicable valve
10A to 50A Note 1) 10A to 25A
Ethyl alcohol
F, B
L, J
Ethylene glycol
B
J
Caustic soda (25% ≥ )
—
J
Gas oil
A
H
Silicon oil
A
H
Fuel oil (up to 60°C)
A
H
Fuel oil (up to 100°C)
D
N
Steam system (Steam)
S
Q
Steam system (Boiler water)
—
G, J
Steam system (Condensate)
E
P
Insulation oil
A
H
Naphtha
A
H
Parachloroethylene
A
H
Brake oil
B
J
Water (up to 99°C)
D, E
N, P
Fluid (Application)
∗ lf using for other fluids, please contact SMC.
Note 1) 10A to 25A are Brass (C37) and 32A to 50A are
BC6.
Normally Open (N.O.)
Refer to page 149 for specifications and models.
Option Symbol and Composition
Option symbol Seal material
Standard Note 2)
A
B
C
D Note 2)
E
F Note 1)
G
H
J
K
L Note 1)
N
P
Q
S
T Note 1)
X Note 1)
NBR
FKM
EPDM
PTFE
FKM
EPDM
FKM
NBR
FKM
EPDM
PTFE
FKM
FKM
EPDM
PTFE(FKM)
PTFE(FKM)
NBR
FKM
Coil insulation
type
B
H
Body, Shading
coil material
Fluid Name and Option
Holder material
(in core assembly)
Polyacetal
Brass (C37)
or BC6,
Copper
Stainless steel
Polyacetal
B
Stainless steel, Silver
(15 to 25 A)
Not available for
32 A to 50 A
Stainless steel
H
B
H
Brass (C37)
or BC6, Copper
Option symbol and body material
Brass (C37) or BC6 Stainless steel
Applicable valve
15A to 50ANote 1) 15A to 25A
Caustic soda (25% ≥ )
—
J
Gas oil
A
H
Silicon oil
A
H
Fuel oil (up to 60°C)
A
H
Fuel oil (up to 100°C)
D
N
Steam system (Steam)
S
Q
Steam system (Boiler water)
—
G, J
Steam system (Condensate)
E
P
lnsulation oil
A
H
Parachloroethylene
A
H
Brake oil
B
J
Water (up to 99°C)
E
N, P
Fluid (Application)
∗ lf using for other fluids, please contact SMC.
Note 1) 15A to 25A are Brass (C37) and 32A to 50A are
BC6.
Polyacetal
Stainless steel
Note 1) Non-lube type. For other options, “-X21” at the end of product number represents the non-lube option.
Note 2) Grease has been applied to the core part.
146
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
7-2-12-VXP.qxd
10.2.15 11:27 AM
Page 1
Pilot Operated 2 Port Solenoid Valve
Series VXP21/22/23
For Air, Gas, Steam, Water and Oil
Normally Closed (N.C.)
Fluid
JIS Symbol
Water (Standard)
Turbine oil
Made to Order Note 2)
Option Note 1)
Standard specifications
OUT
Steam
High temperature water
High temperature oil
(S)
(D, E)
(D)
Air
X44
VX2
Note 1) Refer to page 146 “Applicable Fluids Check List” for details of special fluids outside of the
standard options and specifications.
Note 2) Please contact SMC for details.
IN
VXZ
Model/Valve Specifications <Normally Closed>
Min. operating
pressure
differential
(MPa)
Thread
Connection Orifice
dia.
Model
(mmø)
14
38
12
34
10
10
15
10
15
20
Thread
Flange
Connection
VXP2130-02
VXP2130-03
VXP2140-03
VXP2130-04
VXP2140-04
VXP2150-06
Orifice
diameter
(mmø)
1
—
—
—
—
32A
40A
50A
25
35
40
50
35
40
50
11 4
11 2
2
—
—
—
0.04
0.04
0.04
0.04
0.04
0.04
Flow characteristics
Steam
Oil
Water, Oil, Steam
AC DC AC Av x 10-6m2 Cv converted C [dm3/(s·bar)]
8.5
0.5 0.4 0.9
1.9
46
9.2
2.4
58
0.5 0.4 0.9
18
4.2
100
0.7 0.7 1.0
9.2
2.4
58
0.5 0.4 0.9
20
5.3
130
0.7 0.7 1.0
38
9.2
220
0.7 0.7 1.0
Maximum operating pressure differential (MPa)
Water
AC DC
0.7 0.5
0.7 0.5
1.0 1.0
0.7 0.5
1.0 1.0
1.0 1.0
Air
AC DC
0.9 0.7
0.9 0.7
1.0 1.0
0.9 0.7
1.0 1.0
1.0 1.0
Model
Min. operating
pressure
differential
(MPa)
VXP2260-10
VXP2270-12
VXP2380-14
VXP2390-20
VXP2270-32
VXP2380-40
VXP2390-50
0.04
0.03
0.03
0.03
0.03
0.03
0.03
Note)
Air
b
0.35
0.35
0.35
0.35
0.35
0.30
Flow characteristics
Steam
Oil
Water, Oil, Steam
Air
Cv converted Effective area (mm2)
AC DC AC Av x 10-6m2
0.7 0.7 1.0
290
12
215
0.7 0.7 1.0
550
23
415
0.7 0.7 1.0
740
31
560
0.7 0.7 1.0
1200
49
880
0.7 0.7 1.0
550
23
415
0.7 0.7 1.0
740
31
560
0.7 0.7 1.0
1200
49
880
Cv
2.0
2.4
5.0
2.4
5.5
9.2
Max. system Mass
pressure
(MPa) (g)
VXE
420
420
740
500
740
1300
VXP
Water,
Air, Oil
1.5
Steam
1.0
Maximum operating pressure differential (MPa)
Water
AC DC
1.0 1.0
1.0 1.0
1.0 1.0
1.0 1.0
1.0 1.0
1.0 1.0
1.0 1.0
Air
AC DC
1.0 1.0
1.0 1.0
1.0 1.0
1.0 1.0
1.0 1.0
1.0 1.0
1.0 1.0
VXD
Note)
Max. system
pressure
(MPa)
Mass
(g)
Water
Air Oil
1.5
Steam
1.0
1810
3300
4200
5400
5900
7300
9200
Note) Mass of grommet type. Add 10 g for conduit type, 30 g for DIN terminal type, 60 g for conduit terminal type respectively.
• Refer to “Glossary of Terms” on page 26 for detail of max. operating pressure differential and max. system pressure.
• VXP2130: Option “C”, “K”, “Q”, “S” only.
VXR
VXH
VXF
VX3
VXA
VCH첸
VDW
VQ
LVM
Solenoid Specifications
Model
VXP21
Power
source
AC
DC
VXP22
AC
DC
VXP23
AC
DC
Frequency
(Hz)
50
60
—
50
60
—
50
60
—
Apparent power (VA)
Inrush
Holding
20 (32)
11
17 (28)
7
—
—
40
18
35
12
—
—
50
21
45
17
—
—
Power consumption (W)
(Holding)
4.5
3.2
6
7.5
6
8
11
9.5
11.5
Be sure to read “Specific
Product Precautions.”
Temperature rise (°C)
(Rated voltage)
45
35
55
60
50
60
65
60
65
VCA
VCB
VCL
VCS
VCW
Note) • The return voltage is 20% or more of the rated voltage for AC and 2% or more for DC.
• The allowable voltage fluctuation rate is ±10% of the rated voltage value for both AC and DC.
• When the ambient temperature is 20°C ± 5°C and rated voltage is applied.
• For VXP2130, changing coils from AC to DC and vice versa is impossible, because of different
9
5
core shapes. VXP2140, 22 760, 23 8 0 are possible to exchange coil from AC to DC, but
impossible from DC to AC.
(Hum sound may generate because of no shading coil for DC.)
• ( ): VXP2130
Operating Fluid and Ambient Temperature
Temperature
conditions
Maximum
Minimum
Power
source
AC
DC
AC
DC
Water
(Standard)
60
40
1
Air
(Standard)
80
60
Operating fluid temperature (°C)
Note 3)
Note 3)
High temperature oil
High temperature water
Oil
(D)
(D, E)
(Standard)
99
100
60
—
40
—
–10 Note 1)
–5 Note 2)
—
—
Note 3)
Steam
(S)
183
—
—
Ambient
temperature
(°C)
60
40
–10
2
Note 1) Dew point: –10°C or less
Note 2) 50 mm /s or less
Note 3) “D”, “E” etc. in parentheses are option symbols.
Note 4) VXP2130: Option “C”, “K”, “Q”, “S” only.
147
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series VXP21/22/23
How to Order (Normally Closed)
VXP21
VXP22
VXP23
0
Bracket
Nil
B
Model
Thread connection sizes
are available from 02 to
10.
Body size
3
4
5
6
7
8
9
Electrical option
10A
15A
20A
25A
32A
40A
50A
Nil
S
L
Z
Electrical entry
G
C
D
T
Normally closed/Single unit
Standard Specifications
Rated voltage
1
2
3
4
5
6
7
8
9
Select an option mark in page 146 by "Applicable Fluids
Check List" for special fluids outside of the standard.
VXP2130: Option “C”, “K”, “Q”, “S” only.
Connection
Thread
Flange
02
03
04
06
10
12
14
20
32
40
50
14
38
12
34
1
11 4
11 2
2
For 32A
For 40A
For 50A
∗ Refer to the table (1) given below for availability.
Table(1)
Connection Size and Applicable Model
Connection
Size
14
38
Thread
Flange
12
34
1
11 4
11 2
2
32A
40A
50A
Applicable model
VXP2130-02
VXP2130-03, VXP2140-03
VXP2130-04, VXP2140-04
VXP2150-06
VXP2260-10
VXP2270-12
VXP2380-14
VXP2390-20
VXP2270-32
VXP2380-40
VXP2390-50
Ordering example
(Example) Series VXP22, Rc 1 1/4, 100 VAC
Grommet
(Part no.) VXP2270-12-1G
Grommet
Conduit
DIN terminal
Conduit terminal
∗ Refer to the table (2) given
below for availability.
Solenoid valve option
Nil
None
With surge voltage suppressor
With indicator light
With light/surge voltage suppressor
∗ Refer to the table (2) given below for availability.
Valve/Body
0
None
With bracket
Thread type
Nil
T
F
N
Rc
NPTF
G
NPT
100 VAC 50/60 Hz
200 VAC 50/60 Hz
110 VAC 50/60 Hz
220 VAC 50/60 Hz
24 VDC
12 VDC
240 VAC 50/60 Hz
48 VAC 50/60 Hz
Other (Please contact SMC separately.)
∗ Refer to the table (2) given below for availability.
Refer to page 156 for ordering coil
only.
Table(2)
Rated Voltage-Electrical Entry-Electrical Option
Insulation type
Electrical entry
Electrical option
1 (100 V)
2 (200 V)
3 (110 V)
AC
4 (220 V)
7 (240 V)
8 (48 V)
5 (24 V)
DC
6 (12 V)
G
S Note)
앬
앬
앬
앬
앬
앬
앬
앬
Class B
C
D, T
—
S
L, Z
앬
앬
앬
앬
앬
앬
앬
앬
앬
앬
앬
앬
—
앬
앬
—
앬
앬
앬
앬
앬
—
앬
앬
G, C
—
앬
앬
앬
앬
앬
—
—
—
Class H
T
S
L, Z
앬
앬
앬
앬
앬
앬
앬
앬
—
앬
—
앬
—
—
—
—
Note) Surge voltage suppressor is attached in the middle of lead wire.
Made to
Order
Made to Order Specifications
on JIS C 0920
Splashproof Specifications ( Based
Based on IEC529IP-X4 )
VXP Model — Port size — Electrical entry - X36
DIN terminal or class H coil not available.
148
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
7-2-12-VXP.qxd
10.2.15 11:27 AM
Page 2
Pilot Operated 2 Port Solenoid Valve
Series VXP21/22/23
For Air, Gas, Steam, Water and Oil
Normally Open (N.O.)
Fluid
Standard specifications
JIS Symbol
OUT
Water (Standard)
Turbine oil
Note 1)
Option
Steam
High temperature water
High temperature oil
Made to Order
Note 2)
(S) Air
(D, E)
(D)
X44
VX2
Note 1) Refer to page 146 “Applicable Fluids Check List” for details of special fluids outside of the
standard options and specifications.
Note 2) Please contact SMC for details.
IN
VXD
VXZ
Model/Valve Specifications <Normally Open>
Connection
Orifice
dia.
Thread Flange
(mmø)
38
—
15
12
—
15
34
—
20
Connection
Thread Flange
1
11 4
11 2
2
—
—
—
—
—
—
—
32A
40A
50A
Orifice
dia.
(mmø)
25
35
40
50
35
40
50
Model
Min. operating
pressure differential
(MPa)
VXP2142-03
VXP2142-04
VXP2152-06
0.04
0.04
0.04
Model
Min. operating
pressure differential
(MPa)
VXP2262-10
VXP2272-12
VXP2382-14
VXP2392-20
VXP2272-32
VXP2382-40
VXP2392-50
0.04
0.03
0.03
0.03
0.03
0.03
0.03
Max. operating pressure differential (MPa)
Water, Air Oil
Steam
AC/DC AC/DC AC
0.7
0.6
0.7
0.7
0.6
0.7
0.7
0.6
0.7
Max. operating pressure differential (MPa)
Water, Air Oil
Steam
AC/DC AC/DC AC
0.7
0.7
0.6
0.7
0.6
0.7
0.7
0.6
0.7
0.7
0.6
0.7
0.7
0.6
0.7
0.7
0.6
0.7
0.7
0.6
0.7
Flow characteristics
Water, Oil, Steam
Air
Av x 10-6m2 Cv converted C [dm3/(s·bar)]
b
100
4.2
18
0.35
130
5.3
20
0.35
220
9.2
38
0.30
Flow characteristics
Water, Oil, Steam
Air
Av x 10-6m2 Cv converted Effective area (mm2)
290
12
215
550
23
415
740
31
560
1200
49
880
550
23
415
740
31
560
1200
49
880
Cv
5.0
5.5
9.2
Note)
Max. system
pressure
(MPa)
Mass
(g)
Water,
Air, Oil
1.5
Steam
1.0
760
760
1320
VXE
VXP
VXR
VXH
Note)
Max. system
pressure
(MPa)
Mass
(g)
Water,
Air, Oil
1.5
Steam
1.0
1850
3300
4200
5400
5900
7300
9200
VXF
VX3
VXA
VCH첸
Note) Mass of grommet type. Add 10 g for conduit type, 30 g for DIN terminal type, 60 g for conduit terminal type respectively.
• Refer to “Glossary of Terms” on page 26 for details of max. operating pressure differential and max. system pressure.
VDW
VQ
Solenoid Specifications
Model
Power
source
AC
VXP21
DC
AC
VXP22
DC
AC
VXP23
DC
Frequency
(Hz)
50
60
—
50
60
—
50
60
—
Apparent power (VA)
Inrush
Holding
25
12
20
8
—
—
45
20
40
15
—
—
60
25
50
20
—
—
LVM
Be sure to read “Specific
Product Precautions.”
Power consumption (W) Temperature rise (°C )
(Holding)
(Rated voltage)
5
50
3.5
35
6
50
8
55
6.5
45
8
50
10.5
60
9.5
50
11.5
55
VCA
VCB
VCL
VCS
Note) • They are values in an ambient temperature of 20°C ±5°C and application of rated voltage.
• Changing coils from AC to DC and vice versa is impossible, because of different core shapes.
• Return voltage is 20% or more of the rated value at AC power and 5% or more at the DC power.
• The allowable voltage fluctuation rate is ±10% of the rated voltage value for both AC and DC.
VCW
Fluid and Ambient Temperature
Temperature
conditions
Maximum
Minimum
Power
source
AC
DC
AC
DC
Fluid temperature (°C )
Water
(Standard)
60
40
1
Air
(Standard)
80
60
–10
Oil
(Standard)
60
40
Note 1)
–5
Note 2)
High temperature water
(X, E)
Note 3)
High temperature oil
99
—
(D)
100
—
—
—
Note 3)
Note 3)
Steam
(S)
183
—
—
Ambient temperature
(°C )
60
40
–10
2
Note 1) Dew point: –10°C or less
Note 2) 50 mm /s or less
Note 3) “D”, “E” etc. in parentheses are option symbols.
149
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series VXP21/22/23
How to Order (Normally Open)
VXP21
VXP22
VXP23
2
Bracket
Nil
B
None
With bracket
Thread connection sizes
are available from 03 to
10.
Model
Electrical option
Body size
4
5
6
7
8
9
Nil
S
L
Z
15A
20A
25A
32A
40A
50A
∗ Refer to the table (2) given below for availability.
Electrical entry
G
C
D
T
Valve/Body
Normally open/Single unit
2
Rated voltage
Standard Specifications
1
2
3
4
5
6
7
8
9
Select an option mark in page 146 by "Applicable Fluids
Check List" for special fluids outside of the standard.
Connection
Thread
Flange
03
04
06
10
12
14
20
32
40
50
38
12
34
1
11 4
11 2
2
For 32A
For 40A
For 50A
Table (1)
Connection Size and Applicable Model
Size
38
12
34
Thread
Flange
1
114
112
2
32A
40A
50A
Applicable model
VXP2142-03
VXP2142-04
VXP2152-06
VXP2262-10
VXP2272-12
VXP2382-14
VXP2392-20
VXP2272-32
VXP2382-40
VXP2392-50
Ordering example
(Example) Series VXP22, 32A Flange, 200 VAC,
DIN terminal
(Part no.) VXP2272-32-2D
100 VAC 50/60 Hz
200 VAC 50/60 Hz
110 VAC 50/60 Hz
220 VAC 50/60 Hz
24 VDC
12 VDC
240 VAC 50/60 Hz
48 VAC 50/60 Hz
Other (Please contact SMC separately.)
∗ Refer to the table (2) given below for availability.
Refer to page 156 for ordering coil
only.
Thread type
Nil
∗ Refer to the table (1) given below for availability.
Connection
Grommet
Conduit
DIN terminal
Conduit terminal
∗ Refer to the table (2) given
below for availability.
Solenoid valve option
Nil
None
With surge voltage suppressor
With indicator light
With light/surge voltage suppressor
T
F
N
Rc
NPTF
G
NPT
Table (2)
Rated Voltage-Electrical Entry-Electrical Option
Insulation type
Electrical entry
Electrical option
1 (100 V)
2 (200 V)
3 (110 V)
AC
4 (220 V)
7 (240 V)
8 (48 V)
5 (24 V)
DC
6 (12 V)
G
S Note)
앬
앬
앬
앬
앬
앬
앬
앬
Class B
C
D, T
—
S
L, Z
앬
앬
앬
앬
앬
앬
앬
앬
앬
앬
앬
앬
—
앬
앬
—
앬
앬
앬
앬
앬
—
앬
앬
G, C
—
앬
앬
앬
앬
앬
—
—
—
Class H
T
S
L, Z
앬
앬
앬
앬
앬
앬
앬
앬
—
앬
—
앬
—
—
—
—
Note) Surge voltage suppressor is attached in the middle of lead wire.
Made to
Order
Made to Order Specifications
on JIS C 0920
Splashproof Specifications ( Based
Based on IEC529IP-X4 )
VXP Model — Port size — Electrical entry - X36
DIN terminal or class H coil not available.
150
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Pilot Operated 2 Port Solenoid Valve
Series VXP21/22/23
For Air, Gas, Steam, Water and Oil
Construction/Principle Parts Material
Normally Closed (N.C.)
Normally Open (N.O.)
VXP2130
VXP2142/2152/2262
VX2
VXD
VXZ
VXE
VXP2140/2150/2260
VXP
VXR
VXH
VXP2272/2382/2392
VXF
VX3
VXP2270/2380/2390
VXA
VCH첸
VDW
VQ
LVM
VCA
Operation
<Valve opened> When the coil o is energized, the armature assembly u is attracted into the core of the core assembly y and the
pilot valve A opens. Then the pressure in the pressure action
chamber B falls to open the main valve C.
<Valve closed> When the coil o is not energized, the pilot valve A
is closed and the pressure in the pressure action chamber B rises
and the main valve C closes.
Operation
<Valve closed> When the coil u is energized, the opened pilot A
closes, the pressure in pressure action chamber B rises and the
main valve C closes.
<Valve opened> When coil u is not energized, the closed pilot
valve A opens, the pressure in pressure action chamber B drops
and the main valve C opens.
VCB
VCL
VCS
VCW
No.
Description
1
Body
2
Bonnet
3
O-ring
4
Disk
assembly
5
Valve spring
6
Core assembly
7
8
9
Armature
assembly
Return spring
Coil assembly
Size
10A to 25A
32A to 50A
10A to 25A
32A to 50A
—
10A to 25A
32A to 50A
—
10A to 25A
32A to 50A
—
—
—
Material
Standard
Brass (C37)
BC6
Brass (C37)
BC6
NBR
Stainless steel,
Brass (C37),
NBR
Stainless steel
Stainless steel,
Copper
Stainless steel,
NBR
Stainless steel
Class B molded
Option
Stainless steel
—
Stainless steel
—
FKM/EPDM
Stainless steel, FKM
Stainless steel, EPDM
Stainless steel, Brass (C37)
FKM/EPDM
—
Stainless steel, Silver
—
Stainless steel, FKM
Stainless steel, EPDM
—
Class H molded
No.
Description
1
Body
2
Bonnet
3
O-ring
4
Disk
assembly
5
Valve spring
Size
15A to 25A
32A to 50A
15A to 25A
32A to 50A
—
15A to 25A
32A to 50A
—
15A to 25A
6
Core assembly
32A to 50A
7
Coil assembly
—
Material
Standard
Option
Brass (C37)
Stainless steel
BC6
—
Brass (C37)
Stainless steel
BC6
—
NBR
FKM/EPDM
Stainless steel, FKM
Stainless steel,
Stainless steel, EPDM
Brass (C37),
Stainless steel, Brass (C37)
NBR
FKM/EPDM
Stainless steel
—
Stainless steel, Stainless steel, Silver
FKM/EPDM, PTFE
Copper, NBR
Polyacetal
Stainless steel, Copper,
PTFE
FKM/EPDM, PTFE
Class B molded
Class H molded
151
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series VXP21/22/23
Dimensions (Orifice Diameter: 10 mmø)
Normally Closed: VXP2130
Conduit: C
(67)
(52)
290 ±10
20
24
26
50
Bracket
IN
OUT
(28)
2 x Rc 1/4, 3/8, 1/2
(2.3)
(5.5)
(7.5)
Bracket
G 1/2
11 14
11 14
IN
OUT
270 ±10
(27) 30
(33) 36
(5.5)
(27) 30
(7.5)
39
(2.3)
(33) 36
23
20
80 86
71 77
(67)
(52)
80 86
66.5 73.5
63 69
Grommet: G
26
24
50
22 28
40
2 x Rc 1/4, 3/8, 1/2
(28)
22 28
40
DIN terminal: D
59
47
Cable ø6 to ø12
Bracket
24
26
G 1/2
(28)
2 x Rc1 /4, 3/8, 1/2
50
(52)
(67)
(33) 36
11 14
22
Hexagon width
across flats
80 86
34.5
(44)
(5.5)
(27) 30
IN
OUT
63 69
(2.3)
(7.5)
22 28
40
Conduit terminal: T
26
24
2 x Rc 1/4, 3/8, 1/2
50
(52)
(67)
(33) 36
98 104
IN
OUT
Bracket
(2.3)
11 14
G 1/2
(27) 30
25
52 55
(7.5)
(27) 30
(5.5)
92 ±2
(28)
22 28
40
59 ±2
쏔: Port size Rc 1/2
152
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Pilot Operated 2 Port Solenoid Valve
Series VXP21/22/23
For Air, Gas, Steam, Water and Oil
Dimensions (Orifice Diameter: 15 mmø, 20 mmø, 25 mmø)
Normally closed: VXP2140/2150/2260 Normally open: VXP2142/2152/2262
Grommet: G
Conduit: C
VX2
VXD
VXZ
VXE
VXP
VXR
2xP
Port size
(2 x ø8.5)
VXH
Mounting hole
VXF
VX3
VXA
VCH첸
Conduit terminal: T
VDW
VQ
LVM
VCA
VCB
VCL
VCS
VCW
P
Port
size
Normally closed Normally open
Rc
3 8, 1 2
VXP2140
VXP2142
34
VXP2150
VXP2152
1
VXP2260
VXP2262
Model
A
B
C
D
E
63 104 (116) 26 71 28
80 118 (136) 32.5 87 35
90 133 (150) 36.5 97 40
Electrical entry
Grommet Conduit Conduit terminal
N
Q N Q
N
Q R
3 14 29 34 20 30 69 (76) 23 61 39 61 (68) 92 59
8 17.5 37 43 20 30 77 (84) 23 69 39 69 (76) 92 59
8 20 43 47 23 35 87 (97) 25.5 79 41.5 79 (89) 95 62
F
H
J
K
L
M
Bracket
a b c d e f
57 34 39 65 47 57
74 51 45.5 78 52 62
81 58 49.5 86 57 67
( ): N.O.
153
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series VXP21/22/23
Dimensions
Normally closed: VXP2270/2380/2390 Normally open: VXP2272/2382/2392
Grommet: G
2xP
Port size
Conduit: C
DIN terminal: D
Cable
ø6 to ø12
Conduit terminal: T
P
Applicable
thread
Normally closed Normally open
Pc
VXP2270
VXP2272
1 14
1 12
VXP2380
VXP2382
2
VXP2390
VXP2392
Model
Electrical entry
Grommet
Conduit
DIN terminal
Conduit terminal
M
N
M
N
M
N Q
M
N Q
125 128 (145) 26.5 43.5 51.5 53 67.5 57.5 23 35 92 (102) 25.5 84 (94 ) 41.5 84 (94) 60 48 84 (94) 95 62
132 144 (159) 30 46.5 54.5 60 72 60 25.5 40 103 (113) 28
95 (105) 44.5 95(105 ) 62 50 95(105) 97 64
150 160 (175) 35.5 52 59 71 81 69 25.5 40 114 (124) 28 106 (117 ) 44.5 106(117) 62 50 106(117) 97 64
A
B
C
D
E
F
H
J
K
L
( ): N.O.
154
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Pilot Operated 2 Port Solenoid Valve
Series VXP21/22/23
For Air, Gas, Steam, Water and Oil
Dimensions
Normally closed: VXP2270/2380/2390 Normally open: VXP2272/2382/2392
Grommet: G
VX2
VXD
VXZ
VXE
VXP
8 x ø18
VXR
Conduit: C
VXH
DIN terminal: D
VXF
VX3
VXA
VCH첸
Cable
ø6 to ø12
VDW
VQ
LVM
VCA
VCB
Conduit terminal: T
VCL
VCS
VCW
Model
Applicable
A B C
D
E F H J
Normally closed Normally open flange
VXP2270
VXP2272
32A 160 135 67.5 169 (186.5) 51.5 100 36 23
40A 170 140 70 184 (199) 54.5 105 42 25.5
VXP2380
VXP2382
50A 180 155 77.5 202.5(217.5) 59 120 52 25.5
VXP2390
VXP2392
Electrical entry
DIN terminal
Conduit terminal
Grommet
Conduit
M
N
M
N
M
N Q
M
N Q
35 12 92 (102) 25.5 84 (94) 41.5 84 (94) 60 48 84 (94) 95 62
95(105) 44.5 95(105) 62 50 95(105) 97 64
40 14 103 (113) 28
40 14 114 (124) 28 106(117) 44.5 106(117) 62 50 106(117) 97 64
K
L
( ): N.O.
155
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series VXP21/22/23
Solenoid Coil Assembly
How to Order Solenoid Coil Assemblies
VX021 001 C B
01
Rated voltage Note)
VX solenoid coil assembly
Electrical option
Application
Size part number
001
No.1 solenoid
002
No.2 solenoid
003
No.3 solenoid
Nil
Applicable series
Series VXP21
Series VXP22
Series VXP23
S
L
Z
None
With surge voltage suppressor
With indicator light
With light/surge voltage suppressor
Terminal box
Electrical entry
G
C
D
Nil
Grommet
Conduit
DIN terminal
T
None
With terminal box
Coil insulation type
B
H
Class B insulation
Class H insulation
∗ DIN terminal or DC
not available
Ordering example
(Example) Series VXP21, 100 VAC, class B insulation, grommet
(Part no.) VX021-001GB-01
(Example) Series VXP22, 220 VAC, class B insulation, DIN terminal (with terminal box)
(Part no.) VX021-002DBT-04
(Example) Series VXP23, 24 VDC, conduit terminal, with light/surge voltage suppressor
(Part no.) VX021-003CBTZ-05
01
02
03
04
05
06
07
08
13
23
51
53
55
56
100 VAC 50/60 Hz
200 VAC 50/60 Hz
110 VAC 50/60 Hz
220 VAC 50/60 Hz
24 VDC
12 VDC
240 VAC 50/60 Hz
48 VAC 50/60 Hz
24 VAC 50/60 Hz
440 VAC 50/60 Hz
6 VDC
48 VDC
100 VDC
110 VDC
Note) Voltage symbols 01
to 08 are the same
as the solenoid
valve model identification symbols if
the leading zero is
removed.
Coil Combination Table
(Electrical entry - Coil insulation type - Electrical option)
Without
Electrical entry electrical option
Grommet
Conduit
DIN terminal
GB
GH
CB
CH
CBT
CHT
DB
DBT
With electrical option
With
With surge
With light/surge
voltage suppressor indicator light voltage suppressor
GBS
—
—
—
CBTS
CHTS
—
DBTS
—
—
—
—
CBTL
CHTL
—
DBTL
—
—
—
—
CBTZ
CHTZ
—
DBTZ
∗ Applicable voltages for with indicator light or with light/surge voltage
suppressor are 100 VAC, 200 VAC, 110 VAC, 220 VAC and 24 VDC.
∗ Applicable voltages for CHTL or CHTZ are 100 VAC, 200 VAC, 110
VAC and 220 VAC.
156
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement