CoreSenseProtectionForCopelandDiscusCompressors presentation01092011
Copeland Discus™ With CoreSense ™ Protection
Jan 2011
Value
Copeland Discus with CoreSense Technology
Provides Higher Value
Copeland
Copeland
Discus With CoreSense Protection
 Basic Protection And Diagnostics
- Oil & Standard Motor Protection
 Communication On Every Discus
Discus With CoreSense Diagnostics
 Applied Cost Savings
- Integration Of Traditional Accessories
- Reduced Wiring
- Reduced Assembly Labor
 Advanced Diagnostics
 Improved Reliability
- Reduced Warranty Costs
 Communications
All 2D, 3D, 4D & 6D Copeland Discus Compressors Have CoreSense Technology On Board
Filename/Presenter-Topic: 1/9/2012
Copeland Discus With CoreSense Protection
vs. CoreSense Diagnostics Feature Comparison
Additional Functionality
Available With
CoreSense Diagnostics
Integrated
I/O Board
Integrated
HPCO / LPCO
Digital Control
Adv. Motor Prot
& Measurement
Optional Field
Retrofit
DLT Protection
DLT Protection
Comm. &
Diagnostics
Comm. &
Diagnostics
Oil
Protection
Oil
Protection
Motor
Protection
Motor
Protection
CoreSense
Protection
CoreSense
Diagnostics
Standard
Filename/Presenter-Topic: 1/9/2012
Copeland Discus With CoreSense Protection Features
1.1
2.2
3.3
4.4
5.5
6.6
7.7
8.8
9.9
10
10.
11
11.
12
12.
13
13.
14
14.
Oil Protection
Motor Protection
Low Oil Pressure Warning
Manual Reset
Compressor “Jog” Feature
External Alarm Relay Contact
Oil Warning & Lockout Notification
Motor Trip Notification (4D/6D Only)
Modbus Communication
Remote Reset
Compressor Run Status (Proofing)
Asset Information
Fault And Run History
Optional Feature
– Discharge Line Temp Protection
CoreSense Protection Functionality Comes Standard On All Copeland Discus Compressors
Filename/Presenter-Topic: 1/9/2012
Copeland Discus With CoreSense Protection Features
1
Oil Protection

Functionality
- Module Will Shut Down The Compressor When Oil Pressure Falls Below 7-9 PSID
For 2 Minutes

Features
- Precise Electronic Control Module To Monitor Oil Pump Differential Pressure Switch
- Oil Trip Triggered By 2 Minutes Of No Positive Oil Pressure
- Provides Alarm Indication Via LED Status Display
- Communications
- External Alarms
2
Motor Protection

Functionality
- Temperature Based PTC Sensors Provide Protection Against High Motor Temps
- Temperature And Low Voltage Conditions

Features:
- PTC Temperature Sensor Based Motor Protection
- Communications
- External Alarms
Filename/Presenter-Topic: 1/9/2012
Copeland Discus With CoreSense Protection Features
3
Low Oil Pressure Warning

CoreSense Protection Will Issue A Warning When Oil Pressure Falls Below 79 PSID
- Green LED Will Flash Once As Warning
4
Manual Reset


5
Compressor Jog Feature




6
Red Button On Bottom Of Module Can Be Pressed To Reset The Module
Alternately, Power To The Module Can Be Cycled
The Compressor Will Stop As Long As The Reset Button On The Bottom of
The CoreSense Protection Module Is Held In.
This Can Be Used For Clearing Liquid During A Start-up.
After The CoreSense Protection Re-boots (Approx 3 Seconds) The
Compressor Will Resume Operation If Demand Is Still Present.
The Reset Button May Be Pushed As Necessary To Stop The Compressor.
External Alarm Relay Contact

CoreSense Protection Provides a N.C. Auxiliary Alarm Contact
Filename/Presenter-Topic: 1/9/2012
Copeland Discus With CoreSense Protection Features
7
Oil Warning & Lockout Notification



8
Motor Trip Notification


9
New Communication Feature
CoreSense Protection Module Will Shut Down The Compressor When Oil
Pressure Falls Below 7-9 PSID For 2 Minutes
The Oil Pressure Lockout May Be Reset Through The E2, Remotely Through
Ultrasite™, Or Other Software If The Reset Option Is Enabled.
New Communication Feature
When A Motor Trip Occurs It Is Communicated to the E2 or 3rd Party Rack
Controller If Equipped.
Modbus Communication


Open MODBUS Communication Protocol
Modbus Protocol Is A Messaging Structure Used To Establish Client-Server
Communication Between Intelligent Devices
Filename/Presenter-Topic: 1/9/2012
Copeland Discus With CoreSense Protection Features
10
Remote Reset



11
Enables Restart of Compressors Without
Traveling To The Site By Using Ultrasite™ or
Other Software If The Remote Reset Option Is
Enabled
Enables Restart Of Compressors
The Service Contractor And End User Policies
Need To Be Considered When Deciding
Whether To Enable Or Disable The Oil Pressure
Remote Reset Feature
Compressor Run Status (Proofing)

Proofing Verifies That The Compressors Is
Running As Commanded By The Suction
Group Requirements
Filename/Presenter-Topic: 1/9/2012
Copeland Discus With CoreSense Protection Features
12
Compressor Asset Information



13
The Commissioning Process Uploads Compressor Asset Information
(Model And Serial Number) Into The Rack Controller For Future
Reference
Useful For Asset Tracking And Service Documentation
Remotely Check The “Name Plate” For Service Replacements
Compressor Fault History


Compressor Events Are Recorded Within The CoreSense Protection
Module
- Last 10 Alarm Codes
- 7 Day Alarm Table
- Total Count Of Each Alarm Code
E2 7 Day Alarm Table For CoreSense
Protection Shown Below
Filename/Presenter-Topic: 1/9/2012
Copeland Discus With CoreSense Protection Features
14
Compressor Run History

Compressor Run History Is Recorded Within The
CoreSense Protection Module Displayed on E2
- Accumulated Runtime Hours
- Runtime Without Good Oil Pressure
- Number of Compressor Starts
15
Discharge Temperature Protection (Optional)

Provide (3) Additional Alarms
- DLT Lockout
- DLT Trip
- DLT Thermistor Fault



Discharge Temperature Protection Related Alarms are
Enabled/Disabled Using A Dip Switch #10
Uses NTC Sensor Probe To Monitor Discharge
Temperature
Default Settings:
- Trip Value ≥ 310F For 2 Sec
- Reset Value ≤ 267F For 2 Sec
- Alarm : No Reset Required
Discharge Temperature
Protection Thermistor
Filename/Presenter-Topic: 1/9/2012
CoreSense Protection
Compressor Warning Condition
#
Flashes
Green LED - Warning Condition
(The Compressor May Run With These Conditions)
1
Low oil pressure - Indicates that the device has detected low oil pressure for longer
than 2 seconds. The compressor is able to run, because not enough time has elapsed
without oil pressure to cause a shutdown. The warning will clear if 2 seconds of good
oil pressure is detected.
2
Not used
3
Discharge Temperature Probe Open Or Disconnected - The system is not reading
temperature data from the discharge temperature sensor input. The compressor is able
to run when this condition is present. The condition will clear if the system reads valid
temperature data from the probe for
more than 2 seconds.
4
Current Sensor Disconnected - The current sensor is not connected to the system. The
compressor continues to run. The condition will clear when the current sensor is
connected to the module for more than two seconds.
5
Communication Error Between CoreSense Protection Module And E2 –
A. The rack controller is not communicating with the CoreSense module. The
compressor continues to run. The condition will clear when a valid message is
received from the rack controller.
B. If the E2 is configured to expect a Sensor Module and none is supplied, the module
will flash Code “5”
Filename/Presenter-Topic: 1/9/2012
CoreSense Protection
Compressor Trip Condition
#
Flashes
Yellow LED - Trip Condition
(Compressor Stops until Condition Clear and/or
Time Delay has Expired)
1
Not used
2
Motor Protector Trip - The motor temperature as
measured by the PTC sensors have exceeded
their trip limit. The compressor will remain off for
at least 2 minutes and until the motor
temperature is below the reset limit.
3
Discharge Temperature - The head temperature
probe has detected a temperature greater than
310 F. The compressor will remain off for at least
2 minutes and until the compressor head is
below the reset limit.
4
Not used
5
Not used
Filename/Presenter-Topic: 1/9/2012
CoreSense Protection
Compressor Lockout Condition
#
Flashes
Red LED - Lockout Condition (RESET
Required)
1
Low Oil Pressure Lockout - The compressor
has accumulated 2 minutes of run time
without sufficient oil.
2
Not used
3
Discharge Temperature - The head
temperature probe has detected a
temperature greater than 310 F and
Discharge Temperature Lockout has been
enabled in the rack controller.
4
Not used
5
Not used
Filename/Presenter-Topic: 1/9/2012
Copeland Discus with CoreSense Protection
Benefits Summary
LED Indicators
for Alerts, Trips, &
Lockouts
Remote Reset
Alarm History
Greater
Refrigeration
Uptime
Lower Maintenance
Costs
Filename/Presenter-Topic: 1/9/2012
Copeland Discus With CoreSense Protection
Support Materials
AE Bulletin – AE1367
Marketing Bulletin
Brochure
www.EmersonClimate.com/CopelandDiscus
Filename/Presenter-Topic: 1/9/2012