DLL2020
DLL2020
Software Configuration Manual
90ACC1620
DLL2020
SOFTWARE CONFIGURATION MANUAL
DATALOGIC S.p.A.
Via Candini 2
40012 - Lippo di Calderara di Reno
Bologna - Italia
DLL2020 Software Configuration Manual
Ed.:02/2003
This manual refers to software version S80E0709 and later
ALL RIGHTS RESERVED
Datalogic reserves the right to make modifications and improvements without prior notification.
Datalogic shall not be liable for technical or editorial errors or omissions contained herein, nor for incidental or
consequential damages resulting from the use of this material.
Product names mentioned herein are for identification purposes only and may be trademarks and or
registered trademarks of their respective companies.
Datalogic S.p.A. 2000 - 2003
(Rev. B)
CONTENTS
1
INTRODUCTION .......................................................................................... 1
2
CONFIGURATION PARAMETERS.............................................................. 2
Interface Selection ........................................................................................ 2
RS232 ........................................................................................................... 3
RS232 Presets.............................................................................................. 3
Baudrate ....................................................................................................... 5
Parity............................................................................................................. 6
DataBits ........................................................................................................ 7
StopBits......................................................................................................... 7
RTS/CTS....................................................................................................... 8
KEYBOARD WEDGE ................................................................................... 9
PC/Terminal Type ......................................................................................... 9
Keyboard Nationality................................................................................... 10
Caps Lock ................................................................................................... 11
Inter Character Delay .................................................................................. 12
OPERATING PARAMETERS..................................................................... 15
Scanning Mode ........................................................................................... 15
Freeze Frame Mode.................................................................................... 16
Single Line Mode (DLL2021 model only) .................................................... 16
Beeper On / Off........................................................................................... 17
Beeper Tone ............................................................................................... 17
LED/Beeper Management........................................................................... 18
Sleep Mode................................................................................................. 18
Same Code Delay....................................................................................... 19
Code Sample Period................................................................................... 22
Buffersize of Scanner.................................................................................. 23
CODE SELECTION .................................................................................... 24
EAN/UPC .................................................................................................... 24
Code 128/EAN 128 ..................................................................................... 31
Code 39 ...................................................................................................... 32
Codabar ...................................................................................................... 34
Interleaved 2/5 ............................................................................................ 37
CODE LENGTH.......................................................................................... 39
Set Minimum Length ................................................................................... 39
Set Fixed Length......................................................................................... 40
Length ......................................................................................................... 42
iii
DATA FORMATTING ................................................................................. 49
Transmit Printable Characters .................................................................... 49
Headers ...................................................................................................... 50
Terminators................................................................................................. 51
Pre-defined Terminators ............................................................................. 52
Code Identifiers........................................................................................... 53
Set Custom Code Identifier ......................................................................... 54
3
LOCAL MODE PROGRAMMING............................................................... 58
A
ASCII CHARACTERS ................................................................................ 65
B
KEYBOARD WEDGE EXTENDED CHARACTERS................................... 97
C
EDITING COMMANDS ............................................................................. 105
iv
HOW TO USE THIS MANUAL
The DLL2020 scanners can be setup with the Default parameters through the User's
Manual or this Software Configuration Manual. Refer to Appendix C for initial
configuration in order to set the default values and to select the interface for your
application. These parameters can be changed to meet different application needs.
In this manual, the configuration parameters are divided into logical groups making it
easy to find the desired function based on its reference group.
In order to change the scanner settings please follow the sequence below:
1)
Open the folded page in Appendix C "Editing Commands" so that the Enter/Exit
and Save Programming Mode code remains visible.
2)
Read the Enter/Exit and Save Programming Mode code to Enter programming
mode; the scanner responds with a double tone beep (Low High)
3)
Change desired scanner settings by scanning the codes in one or more sections
following the procedures given; the scanner responds with a high tone beep
when a valid programming barcode is read or a low tone beep if an unexpected
code is read.
4)
Read the Enter/Exit and Save Programming Mode code to Exit and Save the
new configuration.
Example:
To change the baudrate to 4800, the following codes must be scanned successively:
1. "Enter Programming Mode"
2. "Baudrate 4800"
3. "Exit and Save Programming Mode"
At any time (in Programming Mode) you can scan the "Exit Programming Mode
without Saving" code to cancel the current configuration or the "Restore Factory
Default" code to return to the default settings. Both of these codes Exit programming
mode.
v
To correctly configure the reader using the barcodes provided in this manual, it is
important to aim it onto the desired code without reading the adjacent codes. Since
each page contains three to four barcodes, and the raster scanning pattern is large,
you can use several methods to avoid selecting an adjacent code:
-
Use the Freeze Frame Scanning Mode (see page 16)
-
Use the Single Line Scanning Mode (for DLL2021 models only - see page 16)
-
Cover the adjacent codes with your hand or piece of paper so they cannot be
read
In general, it is advisable to move the reader close to the desired barcode by aligning
the laser pattern on the lateral margin a few centimeters away before moving it over
the desired code.
vi
INTRODUCTION
1
1
INTRODUCTION
This manual provides a detailed description of the software configuration options
available on the DLL2020 scanner. This manual contains three chapters and three
appendices.
The first chapter outlines the manual structure.
The second chapter describes all the configuration parameters that can be set by
reading the barcode labels in each relative section.
The third chapter describes the same programming parameters that can be set in
RS232 by sending the configuration strings to the scanner.
Appendix A provides the list of bar code labels to be read in order to obtain the
desired ASCII characters for Headers, Terminators and Code ID characters.
Appendix B, for Keyboard Wedge interface users, shows the complete list of the
extended Header and Terminator special keys.
Appendix C includes the barcode labels to be read any time it is necessary to
Enter/Exit Programming Mode or to return to default settings.
1
DLL2020
2
2
CONFIGURATION PARAMETERS
The DLL2020 scanners can be configured according to the parameters listed in the
following groups:
• INTERFACE SELECTION
• RS232
• KEYBOARD WEDGE
• OPERATING PARAMETERS
• CODE SELECTION
• CODE LENGTH
• DATA FORMATTING
INTERFACE SELECTION
To select the scanner interface scan the following codes:
1.
Read the "Enter/Exit and Save Programming Mode" code in Appendix C;
2.
Scan either the "RS232 Default" code or the "Keyboard Wedge Default" code.
RS232 is the factory default interface.
RS232 default
8 712345 100100
Programming Mode is exited after scanning this code.
Keyboard Wedge default
8 712345 100131
Programming Mode is exited after scanning this code.
2
CONFIGURATION PARAMETERS - RS232
2
RS232
RS232 PRESETS
Each of the following barcode selections enable a complete preset parameter configuration for
correct use with the respective POS Terminal.
However, specific parameters can always be modified by selecting them from their respective
group in this manual.
The scanner must first be set with the RS232 interface selection. Read the "RS232 default"
scanner interface code.
Wincor Nixdorf Beetle Mode A1
8 712345 190101
Wincor Nixdorf Beetle Mode A2
8 712345 190118
Wincor Nixdorf Beetle Mode B1
8 712345 190125
3
DLL2020
2
Wincor Nixdorf Beetle Mode B2
8 712345 190132
Wincor Nixdorf Beetle Mode B3
8 712345 190149
ICL Mode
8 712345 200008
Fortronic (UK) Mode
8 712345 200107
4
CONFIGURATION PARAMETERS - RS232
2
BAUDRATE
300
8 712345 110000
1200
8 712345 110017
2400
8 712345 110024
4800
8 712345 110031
5
DLL2020
2
9600
8 712345 110048
19200
8 712345 110055
PARITY
None
8 712345 110109
Even
8 712345 110116
6
CONFIGURATION PARAMETERS - RS232
2
Odd
8 712345 110123
DATABITS
7 databits
8 712345 110307
8 databits
8 712345 110314
STOPBITS
1 Stop Bit
8 712345 110208
7
DLL2020
2
2 Stop Bits
8 712345 110215
RTS/CTS
On
8 712345 110536
Off
8 712345 110529
8
CONFIGURATION PARAMETERS - KEYBOARD WEDGE
2
KEYBOARD WEDGE
PC/TERMINAL TYPE
PC XT
8 712345 400002
PC AT
8 712345 400019
PC PS2
8 712345 400026
IBM 347x terminals
8 712345 400033
9
DLL2020
2
IBM 3179 terminal
8 712345 400040
KEYBOARD NATIONALITY
International Keyboard (ALT Method)
8 712345 400200
US
8 712345 400217
UK
8 712345 400224
10
CONFIGURATION PARAMETERS - KEYBOARD WEDGE
2
French
8 712345 400231
German
8 712345 400248
Spanish
8 712345 400255
CAPS LOCK
Off
8 712345 400507
11
DLL2020
2
On
8 712345 400514
INTER CHARACTER DELAY
0 msec
8 712345 130404
1 msec
8 712345 130411
2 msec
8 712345 130428
12
CONFIGURATION PARAMETERS - KEYBOARD WEDGE
2
5 msec
8 712345 130435
10 msec
8 712345 130442
20 msec
8 712345 130459
50 msec
8 712345 130466
13
DLL2020
2
100 msec
8 712345 130473
200 msec
8 712345 130480
500 msec
8 712345 130497
14
CONFIGURATION PARAMETERS – OPERATING PARAMETERS
2
OPERATING PARAMETERS
SCANNING MODE
Two different scanning mode options are available to help prevent adjacent barcode reading in
applications where more than one barcode is present in the DLL2020 laser pattern (i.e. this
manual). These options are:
- Freeze Frame Mode
- Single Line Mode (DLL2021 only).
- the Freeze Frame mode is a special trigger mode allowing to aim the laser pattern onto the
specific code before reading.
To use this mode:
1. Press and hold the scanner trigger. The laser pattern starts blinking but the scanner does
not read the code;
2. Move the scanner towards the barcode (zoom-in);
3. Release the trigger to read the barcode.
- the Single Line mode is a special trigger mode which temporarily switches the full scan pattern
to a single scan line which can then be aimed onto the specific code before reading.
To use this mode:
1. Press and hold the DLL2021 trigger to switch from the full scan pattern to a single scan line;
2. Aim the single scan line onto the barcode to be scanned making sure the line completely
crosses the barcode;
3. Release the trigger to read the barcode.
Both these scanning modes are in addition to the normal omni-directional scanning pattern
which is always available for barcode reading.
CONFIGURATION PROCEDURE
1)
Read the "Enter/Exit and Save Programming Mode" code in Appendix C;
2)
Read the Scanning Mode code;
3)
Read either the Freeze Frame Mode code or the Single Line Mode code;
4)
Read the "Enter/Exit and Save Programming Mode" code again.
Scanning mode
8 712345 150020
15
DLL2020
2
Freeze Frame Mode
Freeze Frame ON
8 712345 150044
Single Line Mode (DLL2021 model only)
Single Line ON
8 712345 150051
16
CONFIGURATION PARAMETERS – OPERATING PARAMETERS
2
BEEPER ON / OFF
The DLL2020 beeper can be enabled or disabled using this code. When DLL2020's
beeper is off, it is possible to check correct reading by monitoring the green good
read LED on top of the scanner. The default setting is "Beeper ON".
To enable or disable the beeper:
1)
Read the "Enter/Exit and Save Programming Mode" Code in Appendix C;
2)
Scan the "Beeper ON/OFF" code to turn the beeper ON or OFF;
3)
Read "Enter/Exit and Save Programming Mode" code again.
Beeper ON/OFF
8 712345 150006
BEEPER TONE
DLL2020 provides four different beeper tones. To change from one tone to another
follow the procedure:
1)
Read the "Enter/Exit and Save Programming Mode" code in Appendix C;
2)
Repeatedly scan the "Beeper Tone" code until the desired tone is heard;
3)
Read "Enter/Exit and Save Programming Mode" code again.
Beeper Tone
8 712345 150013
17
DLL2020
2
LED/BEEPER MANAGEMENT
After decoding
8 712345 151010
After transmission
8 712345 151027
SLEEP MODE
Off
8 712345 130305
After 10 min
8 712345 130312
18
CONFIGURATION PARAMETERS – OPERATING PARAMETERS
2
After 30 min
8 712345 130329
After 60 min
8 712345 130336
SAME CODE DELAY
This function enables a series of programmable timeouts to prevent same code consecutive
reading. The scanner must be completely removed from the code for at least the time specified.
50 msec
8 712345 130107
100 msec
8 712345 130114
19
DLL2020
2
200 msec
8 712345 130121
300 msec
8 712345 130138
400 msec
8 712345 130145
500 msec
8 712345 130152
20
CONFIGURATION PARAMETERS – OPERATING PARAMETERS
2
600 msec
8 712345 130169
700 msec
8 712345 130176
800 msec
8 712345 130183
21
DLL2020
2
CODE SAMPLE PERIOD
50 msec
8 712345 130008
100 msec
8 712345 130015
150 msec
8 712345 130022
200 msec
8 712345 130039
22
CONFIGURATION PARAMETERS – OPERATING PARAMETERS
2
BUFFERSIZE OF SCANNER
Buffersize of scanner > 1
8 712345 110581
Buffersize of scanner = 1
8 712345 110598
23
DLL2020
2
CODE SELECTION
EAN/UPC
All EAN/UPC (ADD ON not sent)
8 712345 141011
EAN/UPC with and without ADD ON
8 712345 141028
All EAN/UPC Off
8 712345 141004
EAN/UPC/ADD ON only
8 712345 141042
24
CONFIGURATION PARAMETERS - CODE SELECTION
NOTE
2
When scanning the following code, barcodes starting with 379, 434,
439, 529 or 977 will only be accepted including ADD ON. If no ADD
ON has been found, the barcode will not be accepted. Barcodes
starting with different characters are accepted with or without ADD
ON.
EAN/UPC/ADD ON only for 379/434/439/529/977,
optional for others
8 712345 141035
EAN/UPC/ADD ON only for 379/434/439/529/977,
not sent for others
8 712345 141073
ADD ON 5 only (ADD ONs must be selected)
8 712345 141059
25
DLL2020
2
ADD ON 2 and 5 only (ADD ONs must be selected)
8 712345 141066
Price check digit verify Off (EAN 13)
8 712345 110765
Price check digit verify, 4 digits price field (EAN 13/UPC A)
8 712345 110789
Price check digit verify, 5 digits price field (EAN 13/UPC A)
8 712345 110772
26
CONFIGURATION PARAMETERS - CODE SELECTION
2
ADD ON with separator
8 712345 110499
ADD ON without separator
8 712345 110482
EAN/UPC Conversions
UPC A without conversion
8 712345 110567
UPC A to EAN 13 conversion
8 712345 110574
27
DLL2020
2
EAN 8 to UPC A conversion
8 712345 110888
NSC to UPC A conversion
8 712345 110918
NSC without conversion
8 712345 110901
UPC E to UPC A conversion
8 712345 110550
28
CONFIGURATION PARAMETERS - CODE SELECTION
2
No UPC E conversion
8 712345 110543
UPC E format with leading zero
8 712345 110437
UPC E format without leading zero
8 712345 110420
Check Digit Options
Transmit UPC A Check digit: OFF
8 712345 110871
29
DLL2020
2
Transmit UPC A Check Digit: ON
8 712345 110864
Transmit UPC E Check Digit: ON
8 712345 110451
Transmit UPC E Check Digit: OFF
8 712345 110444
Transmit EAN 13 Check digit: OFF
8 712345 110857
30
CONFIGURATION PARAMETERS - CODE SELECTION
2
Transmit EAN 13 Check digit: ON
8 712345 110840
Transmit EAN 8 Check digit: OFF
8 712345 110826
Transmit EAN 8 Check digit: ON
8 712345 110833
CODE 128/EAN 128
On
8 712345 143107
31
DLL2020
2
Off
8 712345 143114
Code 128 Options
Code 128/EAN 128 send FNC1 as ]C1
8 712345 143121
Code 128/EAN 128 do not send FNC1 as ]C1
8 712345 143138
CODE 39
On
8 712345 143015
32
CONFIGURATION PARAMETERS - CODE SELECTION
2
Full ASCII On
8 712345 143046
Code 32 On
8 712345 143039
All Code 39 family Off
8 712345 143053
Code 39 Check Digit Options
Transmit CHECK character CODE39:OFF
8 712345 146009
33
DLL2020
2
Transmit CHECK character CODE39:ON
8 712345 146016
Verify CHECK character CODE39: OFF
8 712345 146023
Verify CHECK character CODE39: ON
8 712345 146030
CODABAR
On
8 712345 143022
34
CONFIGURATION PARAMETERS - CODE SELECTION
2
Off
8 712345 143060
CODABAR Start/Stop and Check Digit Options
Transmit start/stop characters in upper case
8 712345 145736
Transmit start/stop characters in lower case
8 712345 145743
No start/stop character transmission
8 712345 145729
35
DLL2020
2
No check digit transmission
8 712345 146047
Transmit check digit
8 712345 146054
Verify CHECK character CODABAR: OFF
8 712345 146061
Verify CHECK character CODABAR: ON
8 712345 146078
36
CONFIGURATION PARAMETERS - CODE SELECTION
2
INTERLEAVED 2/5
On
8 712345 142025
Off
8 712345 142001
Interleaved 2/5 Check Digit Options
Transmit Check character INT 2/5: OFF
8 712345 146085
Transmit CHECK character INT 2/5: ON
8 712345 146092
37
DLL2020
2
Verify CHECK character INT 2/5: OFF
8 712345 146108
Verify CHECK character INT 2/5: ON
8 712345 146115
38
CONFIGURATION PARAMETERS - CODE LENGTH
2
CODE LENGTH
SET MINIMUM LENGTH
To define the desired minimum code length proceed as follows:
1)
If not working in Programming Mode, scan the "Enter/Exit and Save Programming Mode"
code in Appendix C;
2)
Read the "Set Minimum Length" code of the desired barcode type;
3)
Define the minimum length value by reading the corresponding code in the "Length"
section
Code 128, minimum length
8 712345 144135
Code 39, minimum length
8 712345 144142
Codabar, minimum length
8 712345 144159
39
DLL2020
2
Interleaved 2/5, minimum length
8 712345 144111
SET FIXED LENGTH
You can set up to 2 fixed length codes for the following code types. To define the desired code
length proceed as follows:
1)
If not working in Programming Mode, scan the "Enter/Exit and Save Programming Mode"
code in Appendix C;
2)
Read the "Set Fixed Length" code of the desired barcode type;
3)
Define the fixed length value by reading the corresponding code in the "Length" section.
Code 128, fixed length 1
8 712345 144319
Code 128, fixed length 2
8 712345 144357
40
CONFIGURATION PARAMETERS - CODE LENGTH
2
Code 39, fixed length 1
8 712345 144326
Code 39, fixed length 2
8 712345 144364
Codabar, fixed length 1
8 712345 144333
Codabar, fixed length 2
8 712345 144371
41
DLL2020
2
Interleaved 2/5, fixed length 1
8 712345 144302
Interleaved 2/5, fixed length 2
8 712345 144340
LENGTH
Length = 1
8 712345 131012
Length = 2
8 712345 131029
42
CONFIGURATION PARAMETERS - CODE LENGTH
2
Length = 3
8 712345 131036
Length = 4
8 712345 131043
Length = 5
8 712345 131050
Length = 6
8 712345 131067
43
DLL2020
2
Length = 7
8 712345 131074
Length = 8
8 712345 131081
Length = 9
8 712345 131098
Length = 10
8 712345 131104
44
CONFIGURATION PARAMETERS - CODE LENGTH
2
Length = 11
8 712345 131111
Length = 12
8 712345 131128
Length = 13
8 712345 131135
Length = 14
8 712345 131142
45
DLL2020
2
Length = 15
8 712345 131159
Length = 16
8 712345 131166
Length = 17
8 712345 131173
Length = 18
8 712345 131180
46
CONFIGURATION PARAMETERS - CODE LENGTH
2
Length = 19
8 712345 131197
Length = 20
8 712345 131203
Length = 22
8 712345 131227
Length = 24
8 712345 131241
47
DLL2020
2
Length = 26
8 712345 131265
Length = 28
8 712345 131289
Length = 30
8 712345 131302
Length = 32
8 712345 131326
48
CONFIGURATION PARAMETERS – DATA FORMATTING
2
DATA FORMATTING
TRANSMIT PRINTABLE CHARACTERS
Transmit printable characters only
8 712345 143305
Transmit printable and non-printable characters
8 712345 143312
49
DLL2020
2
HEADERS
The scanner can be programmed to output barcode data according to the following format:
[HEADER STRING] [CODE ID] [BARCODE DATA] [TERMINATOR STRING]
The header string is limited to a maximum length of 3 characters.
To program the header string follow the given procedure:
1)
If not working in Programming Mode, scan the "Enter/Exit and Save Programming Mode"
code;
2)
Scan the "Enter Header Programming" code;
3)
Select up to 3 header characters; such characters are available in Appendix A (ASCII
characters) or for Wedge Interface Users in Appendix B (Extended Wedge
Header/Terminator Keys).
4)
Scan the "Exit and Save Headers" code;
5)
Scan the "Enter/Exit and Save Programming Mode" code again OR configure other
parameters
To disable the headers, follow the above procedure omitting Step 3.
Enter Header Programming
8 712345 144203
Exit and Save Headers
8 712345 131005
50
CONFIGURATION PARAMETERS – DATA FORMATTING
2
TERMINATORS
The scanner can be programmed to output barcode data according to the following format:
[HEADER STRING] [CODE ID] [BARCODE DATA] [TERMINATOR STRING]
The terminator string is limited to a maximum length of 3 characters.
To program the terminator string follow the given procedure:
1)
If not working in Programming Mode, scan the "Enter/Exit and Save Programming Mode"
code;
2)
Scan the "Enter Terminator Programming" code;
3)
Select up to 3 header characters; such characters are available in Appendix A (ASCII
characters) or for Wedge Interface Users in Appendix B (Extended Wedge
Header/Terminator Keys).
4)
Scan the "Exit and Save Terminators " code;
5)
Scan the "Enter/Exit and Save Programming Mode" code again OR configure other
parameters
To disable the terminators, follow the above procedure omitting Step 3.
Enter Terminator Programming
8 712345 144210
Exit and Save Terminators
8 712345 131005
51
DLL2020
2
PRE-DEFINED TERMINATORS
To program the terminator string follow the given procedure:
1)
If not working in Programming Mode, scan the "Enter/Exit and Save Programming Mode"
code;
2)
Choose the desired pre-defined terminator from the list below
3)
Scan the "Enter/Exit and Save Programming Mode" code OR configure other parameters.
Terminator = CR
8 712345 110505
Terminator = LF
8 712345 110611
Terminator = CR + LF
8 712345 110512
52
CONFIGURATION PARAMETERS – DATA FORMATTING
2
CODE IDENTIFIERS
A code identifier is a data string, giving information to the host system concerning the barcode
type that has been read.
After scanning the "Enable Default Code Identifiers" code, the scanner is programmed to
transmit data according to the following format:
Code Type
EAN 13
EAN 8
UPC A
UPC E
Code 128
EAN 128
Code 39
Code 32
Codabar
Interleaved 2/5
Code Identifier
F
FF
A
E
#
P
*
*
%
i
Barcode Data
D1 D2 D3 D4 D5 D6 D7 D8 D9 D10 D11 D12 D13
D1 D2 D3 D4 D5 D6 D7 D8
D1 D2 D3 D4 D5 D6 D7 D8 D9 D10 D11 D12
0 D1 D2 D3 D4 D5 D6
D1 Dx
]C1 D1 Dx
D1 Dx
D1 Dx
D1 Dx
D1 Dx
*Enable Default Code Identifiers
8 712345 110475
Disable Code Identifiers
8 712345 110468
* This command cancels Custom Code Identifiers.
53
DLL2020
2
Enable Custom Code Identifiers
8 712345 110413
SET CUSTOM CODE IDENTIFIER
To set a custom code identifier:
1)
If not working in Programming Mode, scan the "Enter/Exit and Save Programming Mode"
code;
2)
Scan the desired "Set Code ID" code;
3)
Select up to 3 Code ID characters; such characters are available in Appendix A (ASCII
characters).
4)
Scan the "Exit and Save Custom Code ID" code at the end of this group;
5)
Scan the " Enter /Exit and Save Programming Mode" code OR configure other parameters.
Set EAN 13 Code ID
8 712345 144005
54
CONFIGURATION PARAMETERS – DATA FORMATTING
2
Set EAN 8 Code ID
8 712345 144012
Set UPC A Code ID
8 712345 144029
Set UPC E Code ID
8 712345 144036
Set EAN128 Code ID
8 712345 144043
55
DLL2020
2
Set Code 128 Code ID
8 712345 144074
Set Code 39 Code ID
8 712345 144081
Set Code 32 Code ID
8 712345 144067
Set Codabar Code ID
8 712345 144098
56
CONFIGURATION PARAMETERS – DATA FORMATTING
2
Set Interleaved 2/5 Code ID
8 712345 144050
Exit and Save Custom Code Identifier
8 712345 131005
57
DLL2020
3
3
3.1
LOCAL MODE PROGRAMMING
ENTER LOCAL MODE
Local Mode Programming allows controlling and configuring the DLL2020 scanners
using the RS232 interface. To use this mode:
1.
Verify that the serial parameters between the DLL2020 and the PC are aligned.
The default parameters on the DLL2020 are: 9600,8,N,2.
2.
Enter Local Mode by sending the following character sequence with at least a
one-second pause between each character:
Ctrl-E + Ctrl-O + ‘!’
When the reader is in LOCAL MODE the ‘>’ character appears on the PC screen. In
this mode the following commands can be sent to the scanner:
KEYBOARD COMMAND
progmode
Tsleep
mm 0e04 50
3.2
DESCRIPTION
Scanner enters programming
mode, scanner responds with
"#" prompt
Show the sleep timeout value
Disable EAN/UPC overflow;
scanner responds : 0E04 54 -> 50
PROGRAMMING MODE
To enter Programming Mode send the "progmode" command from Local Mode (see
par 3.1 above).
When the reader is in PROGRAMMING MODE the ‘#’ character appears on the PC
screen. In this mode it is possible to send any programming command to the
scanner. A complete list of the Programming Mode commands is given in par. 3.3.
To exit Programming Mode and Save the new configuration send the following
commands:
exit
the scanner returns to Local Mode = ">"
save -m=stack the scanner acknowledges the save command = ">"
Ctrl-E
exit Local Mode
58
LOCAL MODE PROGRAMMING
3
Example::
COMMAND
Prompt
Ctrl+E + Ctrl+O + ‘!’
progmode
10008
15000
14310
exit
save -m=stack
Ctrl+E
>
#
#
#
#
>
>
DESCRIPTION
ENTER LOCAL MODE
ENTER PROGRAMMING MODE
Restore factory default
Set Beeper on
(Code128/Ean128 On)
EXIT PROG. MODE
SAVE CONFIGURATION
EXIT LOCAL MODE
59
DLL2020
3
3.3
PROGRAMMING COMMAND STRINGS
INTERFACE SELECTION
DESCRIPTION
RS232 default
Keyboard Wedge default
STRING
10010
10013
RS232
DESCRIPTION
RS232 Presets
Baud Rate
Parity
Databits
Stopbits
RTS/CTS
Wincor Nixdorf Beetle Mode A1
Wincor Nixdorf Beetle Mode A2
Wincor Nixdorf Beetle Mode B1
Wincor Nixdorf Beetle Mode B2
Wincor Nixdorf Beetle Mode B3
ICL Mode
Fortronic (UK) Mode
300
1200
2400
4800
9600
19200
None
Even
Odd
7 databits
8 databits
1
2
RTS/CTS ON
RTS/CTS OFF
STRING
19010
19011
19012
19013
19014
20000
20010
11000
10017
11002
11003
11004
11005
11010
11011
11012
11030
11031
11020
11021
11053
11052
KEYBOARD WEDGE
DESCRIPTION
PC/Terminal Type
Select
Keyboard nationality
60
PC XT
PC AT
PC PS2
IBM 347 x terminals
IBM 3179 terminal
International Keyboard (ALT Method)
US
UK
French
German
Spanish
STRING
40000
40001
40002
40003
40004
40020
40021
40022
40023
40024
40025
LOCAL MODE PROGRAMMING
Caps Lock
Caps Lock
Inter Character Delay
3
KEYBOARD WEDGE (continued)
OFF
ON
0 msec
1 msec
2 msec
5 msec
10 msec
20 msec
50 msec
100 msec
200 msec
500 msec
40050
40051
13040
13041
13042
13043
13044
13045
13046
13047
13048
13049
OPERATING PARAMETERS
DESCRIPTION
Select Scanning Mode
Freeze Frame Mode
Single Line Mode
Beeper
LED/Beeper Management
Sleep Mode
Same Code Delay
Code Sample Period
Buffersize of Scanner
Scanning Mode
Freeze Frame ON
Single Line ON
Beeper ON/OFF
Beeper Tone
After decoding
After transmission
Off
After 10 min.
After 30 min.
After 60 min.
50 msec
100 msec
200 msec
300 msec
400 msec
500 msec
600 msec
700 msec
800 msec
50 msec
100 msec
150 msec
200 msec
Buffersize of Scanner > 1
Buffersize of Scanner = 1
STRING
15002
15004
15005
15000
15001
15101
15102
13030
13031
13032
13033
13010
13011
13012
13013
13014
13015
13016
13017
13018
13000
13001
13002
13003
11058
11059
61
DLL2020
3
EAN/UPC
EAN/UPC
Conversions
CODE 128/
EAN 128
CODE 39
62
CODE SELECTION
All EAN/UPC (ADD ON not sent)
EAN/UPC with and without ADD ON
All EAN/UPC Off
EAN/UPC + ADD ON only
EAN/UPC + ADD ON only for 379/434/439/529/977,
optional for others
EAN/UPC + ADD ON only for 379/434/439/529/977, not
sent for others
ADD ON 5 only (ADD ONs must be selected)
ADD ON 2 and 5 only (ADD ONs must be selected)
Price check digit verify Off (EAN 13)
Price check digit verify, 4 digits price field (EAN 13/UPC A)
Price check digit verify, 5 digits price field (EAN 13/UPC A)
ADD ON Format with Separator
ADD ON Format without Separator
UPC A without conversion
UPC A to EAN 13 conversion
EAN 8 to UPC A conversion
NSC to UPC A conversion
NSC without conversion
UPC E to UPC A conversion
No UPC E conversion
UPC E format with leading zero
UPC E format without leading zero
Transmit UPC A Check digit: OFF
Transmit UPC A Check digit: ON
Transmit UPC E Check Digit: ON
Transmit UPC E Check Digit: OFF
Transmit EAN 13 Check digit: OFF
Transmit EAN 13 Check digit: ON
Transmit EAN 8 Check digit: OFF
Transmit EAN 8 Check digit: ON
Code 128/EAN 128 ON
Code 128/EAN 128 OFF
Code 128/EAN 128 send FNC1 as ]C1
Code 128/EAN 128 do not send FNC1 as ]C1
ON
Full ASCII ON
Code 32 ON
All Code 39 family OFF
Transmit CHECK character CODE39:OFF
Transmit CHECK character CODE39:ON
Verify CHECK character CODE39: OFF
Verify CHECK character CODE39: ON
14101
14102
14100
14104
14103
14107
14105
14106
11076
11078
11077
11049
11048
11056
11057
11088
11091
11090
11055
11054
11043
11042
11087
11086
11045
11044
11085
11084
11082
11083
14310
14311
14312
14313
14301
14304
14303
14305
14600
14601
14602
14603
LOCAL MODE PROGRAMMING
CODABAR
Interleaved 2/5
3
CODE SELECTION
CODABAR ON
CODABAR OFF
Transmit start/stop characters in upper case
Transmit start/stop characters in lower case
No start/stop character transmission
No check digit transmission
Transmit check digit
Verify CHECK character CODABAR: OFF
Verify CHECK character CODABAR: ON
Interleaved 2/5 ON
Interleaved 2/5 OFF
Transmit Check character INT 2/5: OFF
Transmit CHECK character INT 2/5: ON
Verify CHECK character INT 2/5: OFF
Verify CHECK character INT 2/5: ON
14302
14306
14573
14574
14572
14604
14605
14606
14607
14202
14200
14608
14609
14610
14611
CODE LENGTH
DESCRIPTION
Set Minimum Length*
Set Fixed Length*
Length
Code 128
Code 39
CODABAR
Interleaved 2/5
Code 128, Fixed Length 1
Code 128, Fixed Length 2
Code 39, Fixed Length 1
Code 39, Fixed Length 2
CODABAR, Fixed Length 1
CODABAR, Fixed Length 2
Interleaved 2/5, Fixed Length 1
Interleaved 2/5, Fixed Length 2
Length = 1
Length = 2
Length = 3
Length = 4
Length = 5
Length = 6
Length = 7
Length = 8
Length = 9
Length = 10
Length = 11
Length = 12
Length = 13
Length = 14
Length = 15
Length = 16
STRING
14413
14414
14415
14411
14431
14435
14432
14436
14433
14437
14430
14434
13101
13102
13103
13104
13105
13106
13107
13108
13109
13110
13111
13112
13113
13114
13115
13116
63
DLL2020
3
Length
CODE LENGTH (continued)
Length = 17
Length = 18
Length = 19
Length = 20
Length = 22
Length = 24
Length = 26
Length = 28
Length = 30
Length = 32
13117
13118
13119
13120
13122
13124
13126
13128
13130
13132
* Every single "Set Code Length" string must be followed by a Length value
string.
64
ASCII CHARACTERS
A
A ASCII CHARACTERS
'NUL'
8 712345 131005
'SOH'
8 712345 131012
'STX'
8 712345 131029
'ETX'
8 712345 131036
65
DLL2020
A
'EOT'
8 712345 131043
'ENQ'
8 712345 131050
'ACK'
8 712345 131067
'BEL'
8 712345 131074
66
ASCII CHARACTERS
A
'BS'
8 712345 131081
'HT'
8 712345 131098
'LF'
8 712345 131104
'VT'
8 712345 131111
67
DLL2020
A
'FF'
8 712345 131128
'CR'
8 712345 131135
'SO'
8 712345 131142
'SI'
8 712345 131159
68
ASCII CHARACTERS
A
'DLE'
8 712345 131166
'DC1'
8 712345 131173
'DC2'
8 712345 131180
'DC3'
8 712345 131197
69
DLL2020
A
'DC4'
8 712345 131203
'NAK'
8 712345 131210
'SYN'
8 712345 131227
'ETB'
8 712345 131234
70
ASCII CHARACTERS
A
'CAN'
8 712345 131241
'EM'
8 712345 131258
'SUB'
8 712345 131265
'ESC'
8 712345 131272
71
DLL2020
A
'FS'
8 712345 131289
'GS'
8 712345 131296
'RS'
8 712345 131302
'US'
8 712345 131319
72
ASCII CHARACTERS
A
SPACE
8 712345 131326
'!'
8 712345 131333
'"'
8 712345 131340
'#'
8 712345 131357
73
DLL2020
A
'$'
8 712345 131364
'%'
8 712345 131371
'&'
8 712345 131388
'''
8 712345 131395
74
ASCII CHARACTERS
A
'('
8 712345 131401
')'
8 712345 131418
'*'
8 712345 131425
'+'
8 712345 131432
75
DLL2020
A
','
8 712345 131449
'-'
8 712345 131456
'.'
8 712345 131463
'/'
8 712345 131470
76
ASCII CHARACTERS
A
'0'
8 712345 131487
'1'
8 712345 131494
'2'
8 712345 131500
'3'
8 712345 131517
77
DLL2020
A
'4'
8 712345 131524
'5'
8 712345 131531
'6'
8 712345 131548
'7'
8 712345 131555
78
ASCII CHARACTERS
A
'8'
8 712345 131562
'9'
8 712345 131579
':'
8 712345 131586
';'
8 712345 131593
79
DLL2020
A
'<'
8 712345 131609
'='
8 712345 131616
'>'
8 712345 131623
'?'
8 712345 131630
80
ASCII CHARACTERS
A
'@'
8 712345 131647
'A'
8 712345 131654
'B'
8 712345 131661
'C'
8 712345 131678
81
DLL2020
A
'D'
8 712345 131685
'E'
8 712345 131692
'F'
8 712345 131708
'G'
8 712345 131715
82
ASCII CHARACTERS
A
'H'
8 712345 131722
'I'
8 712345 131739
'J'
8 712345 131746
'K'
8 712345 131753
83
DLL2020
A
'L'
8 712345 131760
'M'
8 712345 131777
'N'
8 712345 131784
'O'
8 712345 131791
84
ASCII CHARACTERS
A
'P'
8 712345 131807
'Q'
8 712345 131814
'R'
8 712345 131821
'S'
8 712345 131838
85
DLL2020
A
'T'
8 712345 131845
'U'
8 712345 131852
'V'
8 712345 131869
'W'
8 712345 131876
86
ASCII CHARACTERS
A
'X'
8 712345 131883
'Y'
8 712345 131890
'Z'
8 712345 131906
'['
8 712345 131913
87
DLL2020
A
'\'
8 712345 131920
']'
8 712345 131937
'^'
8 712345 131944
'_'
8 712345 131951
88
ASCII CHARACTERS
A
'`'
8 712345 131968
'a'
8 712345 131975
'b'
8 712345 131982
'c'
8 712345 131999
89
DLL2020
A
'd'
8 712345 132002
'e'
8 712345 132019
'f'
8 712345 132026
'g'
8 712345 132033
90
ASCII CHARACTERS
A
'h'
8 712345 132040
i'
8 712345 132057
'j'
8 712345 132064
'k'
8 712345 132071
91
DLL2020
A
'l'
8 712345 132088
'm'
8 712345 132095
'n'
8 712345 132101
'o'
8 712345 132118
92
ASCII CHARACTERS
A
'p'
8 712345 132125
'q'
8 712345 132132
'r'
8 712345 132149
's'
8 712345 132156
93
DLL2020
A
't'
8 712345 132163
'u'
8 712345 132170
'v'
8 712345 132187
'w'
8 712345 132194
94
ASCII CHARACTERS
A
'x'
8 712345 132200
'y'
8 712345 132217
'z'
8 712345 132224
'{'
8 712345 132231
95
DLL2020
A
'|'
8 712345 132248
'}'
8 712345 132255
'~''
8 712345 132262
'DEL'
8 712345 132279
96
KEYBOARD WEDGE EXTENDED CHARACTERS
B
B KEYBOARD WEDGE EXTENDED CHARACTERS
F1
8 712345 400606
F2
8 712345 400613
F3
8 712345 400620
F4
8 712345 400637
97
DLL2020
B
F5
8 712345 400644
F6
8 712345 400651
F7
8 712345 400668
F8
8 712345 400675
98
KEYBOARD WEDGE EXTENDED CHARACTERS
B
F9
8 712345 400682
F10
8 712345 400699
F11
8 712345 400705
F12
8 712345 400712
99
DLL2020
B
Tab
8 712345 400804
Enter (alpha)
8 712345 400811
Enter (numpad)
8 712345 400828
Backspace
8 712345 400835
100
KEYBOARD WEDGE EXTENDED CHARACTERS
B
Delete
8 712345 400842
Esc
8 712345 400859
Left Arrow
8 712345 400866
Right Arrow
8 712345 400873
101
DLL2020
B
Up Arrow
8 712345 400880
Down Arrow
8 712345 400897
Page Up
8 712345 400903
Page Down
8 712345 400910
102
KEYBOARD WEDGE EXTENDED CHARACTERS
B
Home
8 712345 400927
End
8 712345 400934
103
B
104
DLL2020
EDITING COMMANDS
C
C EDITING COMMANDS
OPEN THIS PAGE TO READ THE DESIRED EDITING
COMMANDS
105
EDITING COMMANDS
C
RESTORE DEFAULT
ENTER AND EXIT
Restore Factory Default
Enter/Exit and Save Programming Mode
8
712345
100087
8 712345 100001
‹ RS232 Default
8 712345 100100
Keyboard Wedge Default
8 712345 100131
Programming Mode is exited after scanning any of these codes.
Exit Programming Mode without Saving
8 712345 100094
DLL2020
Software Configuration Manual
90ACC1620
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement