BatteryProtect 65A/100A/220A

BatteryProtect 65A/100A/220A
BatteryProtect 65A / 100A / 220A
www.victronenergy.com
With 7-segment LED display: easy to set up
The BatteryProtect disconnects the battery from non essential loads before it is completely discharged (which
would damage the battery) or before it has insufficient power left to crank the engine.
12/24V auto ranging
The BatteryProtect automatically detects system voltage
Programming made easy
The BatteryProtect can be set to engage / disengage at several different voltages.
The seven segment display will indicate which setting has been chosen.
BatteryProtect BP-65
A special setting for Li-ion batteries
In this mode the Battery Protect can be controlled by the VE.Bus BMS.
Ultra low current consumption
This is important in case of Li-ion batteries, especially after low voltage shutdown.
Please see our Li-ion battery datasheet and the VE.Bus BMS manual for more information.
Over voltage protection
To prevent damage to sensitive loads due to over voltage, the load is disconnected whenever the DC voltage
exceeds 16 V respectively 32 V.
BatteryProtect BP-100
Ignition proof
No relays but MOSFET switches, and therefore no sparks.
Delayed alarm output
The alarm output is activated if the battery voltage drops below the preset disconnect level during more than 12
seconds. Starting the engine will therefore not activate the alarm. The alarm output is a short circuit proof open
collector output to the negative (minus) rail, max. current 50 mA. The alarm output is typically used to activate a
buzzer, LED or relay.
Delayed load disconnect and delayed reconnect
The load will be disconnected 90 seconds after the alarm has been activated. If the battery voltage increases again
to the connect threshold within this time period (after the engine has been started for example), the load will not
be disconnected.
The load will be reconnected 30 seconds after the battery voltage has increased to more than the preset
reconnect voltage.
BatteryProtect BP-220
Connector with preassembled DC
minus cable (included)
BatteryProtect
BP-65
Maximum continuous load current
Peak current
Operating voltage range
Current consumption
Alarm output delay
Maximum load on alarm output
Load disconnect delay
Load reconnect delay
Default thresholds
Operating temperature range
Connection
Weight
65A
300A
Dimensions (hxwxd)
Victron Energy B.V. | De Paal 35 | 1351 JG Almere | The Netherlands
General phone: +31 (0)36 535 97 00 | Fax: +31 (0)36 535 97 40
E-mail: [email protected] | www.victronenergy.com
BP-100
BP-220
100A
220A
600A
600A
6 –35V
When on: 1,5 mA When off or low voltage shutdown : 0,6 mA
12 seconds
50 mA (short circuit proof)
90 seconds (immediate if triggered by the VE.Bus BMS)
30 seconds
Disengage: 10,5V or 21V Engage: 12V or 24V
Full load: -40°C to +40°C (up to 60% of nominal load at 50°C)
M6
M8
M8
0,2 kg 0.5 lbs
0,5 kg 0.6 lbs
0,8 kg 1.8 lbs
40 x 48 x 106 mm
1.6 x 1.9 x 4.2 inch
59 x 42 x 115 mm
2.4 x 1.7 x 4.6 inch
62 x 123 x 120 mm
2.5 x 4.9 x 4.8 inch