General catalogue Panasonic AQUAREA 2014 EN

General catalogue Panasonic AQUAREA 2014 EN
NEW
AQUAREA RANGE
HIGH-EFFICIENCY HEAT
PUMP TECHNOLOGY
2014 - 2015
NEW AQUAREA AIR TO WATER HEAT PUMP 2014 - 2015
NEW 2014 / 2015
AQUAREA AIR TO WATER HEAT PUMP
Summary
HISTORY OF AIR CONDITIONING GROUP ........................................................................................................................6
PANASONIC – LEADING THE WAY IN HEATING & COOLING .............................................................................................7
100% PANASONIC: WE CONTROL THE PROCESS ............................................................................................................7
RELIABILITY FACTS:RELIABLE COMFORT COMES FROM RELIABLE TECHNOLOGIES ...........................................................8
PANASONIC EUROPE ANNOUNCES SUSTAINABILITY DECLARATION ................................................................................10
EXEMPLARY SUSTAINABLE PROJECTS .........................................................................................................................11
PRO CLUB: THE PROFESSIONAL WEBSITE OF PANASONIC ............................................................................................12
AQUAREA DESIGNER ..................................................................................................................................................14
NEW AQUAREA AIR TO WATER HEAT PUMP ..................................................................................................................15
AQUAREA THE BEST SEASONAL EFFICIENCY ................................................................................................................16
PANASONIC HAS DESIGNED A COMPLETELY NEW LINE-UP TO OFFER THE BEST TO OUR CUSTOMERS .............................18
THREE AQUAREA SOLUTIONS ......................................................................................................................................19
NEW HIGH PERFORMANCE FOR LOW CONSUMPTION HOMES. ......................................................................................20
NEW HIGH PERFORMANCE HELPS YOU TO MEET STRICT BUILDING REQUIREMENTS AND REDUCE BUILDING COSTS ........20
NEW T-CAP FOR EXTREMELY LOW TEMPERATURES. INSTALL A CLASS PUMP: INDUSTRY TOP CLASS ENERGY-SAVING! ...22
AQUAREA HT IDEAL FOR RETROFIT: GREEN ENERGY SOURCE WORKS WITH EXISTING RADIATORS ..................................24
PANASONIC AQUAREA HT IS SUPER EFFICIENT EVEN AT LOW TEMPERATURE ................................................................25
AQUAREA COMMERCIAL SOLUTIONS FOR BEST SAVINGS .............................................................................................26
BY FLEXIBLE WITH YOUR WATER SYSTEM ....................................................................................................................27
NEW ALL IN ONE ........................................................................................................................................................28
NEW REMOTE CONTROL. NEW FEATURES ....................................................................................................................30
NEW INDOOR UNIT DESIGN ........................................................................................................................................31
HEAT AND PRODUCE DOMESTIC HOT WATER FOR FREE ................................................................................................32
CONTROL & CONNECTIVITY.........................................................................................................................................34
CONTROL YOUR HEAT PUMP FROM WHEREVER YOU ARE ..............................................................................................36
CONNECTIVITY: GREAT FLEXIBILITY FOR INTEGRATION INTO YOUR KNX / ZIG BEE / MODBUS PROJECTS ..........................37
AQUAREA LINE-UP! ....................................................................................................................................................38
AQUAREA ALL IN ONE HIGH PERFORMANCE BI-BLOC SINGLE PHASE HEATING AND COOLING .........................................40
AQUAREA ALL IN ONE T-CAP BI-BLOC SINGLE PHASE / THREE PHASE HEATING AND COOLING .......................................41
AQUAREA HIGH PERFORMANCE BI-BLOC SINGLE PHASE HEATING ONLY - SDF /
HEATING AND COOLING - SDC 3 AND 5KW ...................................................................................................................42
AQUAREA HIGH PERFORMANCE BI-BLOC SINGLE PHASE / THREE PHASE HEATING AND COOLING - SDC .........................43
AQUAREA T-CAP BI-BLOC SINGLE PHASE / THREE PHASE HEATING AND COOLING - SXC ................................................44
AQUAREA HT BI-BLOC SINGLE PHASE / THREE PHASE HEATING ONLY - SHF ..................................................................45
AQUAREA HIGH PERFORMANCE MONO-BLOC SINGLE PHASE HEATING ONLY - MDF / HEATING AND COOLING - MDC .......46
AQUAREA HIGH PERFORMANCE MONO-BLOC SINGLE PHASE / THREE PHASE HEATING AND COOLING - MDC ..................47
AQUAREA T-CAP MONO-BLOC SINGLE PHASE / THREE PHASE HEATING AND COOLING - MXC .........................................48
AQUAREA HT MONO-BLOC SINGLE PHASE / THREE PHASE HEATING ONLY - MHF ...........................................................49
AQUAREA AIR RADIATORS...........................................................................................................................................50
ACCESSORIES ............................................................................................................................................................52
EXAMPLES OF INSTALLATIONS WITH AQUAREA MANAGER ............................................................................................54
A TYPICAL EXAMPLE OF SAVINGS AND EFFICIENCIES THAT AQUAREA CAN OFFER TO YOU ..............................................56
HEATING CAPACITY TABLE BASED ON OUTLET TEMPERATURE AND OUTSIDE TEMPERATURE ...........................................58
ERROR CODES ...........................................................................................................................................................67
DIMENSIONS .............................................................................................................................................................68
Quality Management System Certificate
Environmental Management System Certificate
Certified to ISO 9001: 2008
Certified to ISO 14001: 2004
Panasonic Appliances Air-Conditioning
Malaysia. Sdn.Bhd.
Cert. No.: MY-AR 1010
Panasonic Appliances Air-Conditioning
Malaysia Sdn.Bhd.
Cert. No.: MY-ER0112
Certified to ISO 9001: 2008
Certified to ISO 14001: 2004
Panasonic Appliances Air-Conditioning
(GuangZhou) Co., Ltd.
Registration Number: 01209Q20645R5L
Panasonic Appliances Air-Conditioning
(GuangZhou) Co., Ltd.
Registration Number: 02110E10562R4L
NEW
A
class pump
New All in One solution from 3 to 16kW with 200l tank, A class
pump and small foot print. Ideal for new and retrofit homes.
PG 32
NEW
5.08 COP
high efficiency
AQUAREA
HIGH PERFORMANCE
New 5kW Monobloc, the most efficient solution of the market
with a COP of 5.08! Ideal for low consumption homes.
PG 22
NEW
100%
capacity
at -15 ºC
AQUAREA T-CAP
New 16kW T-Cap Bi-Bloc, ideal for retrofit and commercial
applications.
PG 26
NEW
100%
capacity
at -15 ºC
AQUAREA T-CAP
New 9 and 12kW T-Cap Bi-Bloc, with A class pump, higher
efficiency, and energy consumption.
PG 26
NEW
New remote control to improve performance, comfort and to
deliver maximum energy savings.
PG 34
NEW
New, square-chassis hot water tank, with integral 80-litre buffer
tank.
PG 60
3
As we move towards our Centenary in 2018, our
new brand slogan encapsulates Panasonic’s
vision of expanding and pursuing a better life for
each of our customers. Working with our many
partners, we operate in a wide range of fields
such as the home, community, business, travel,
realising a better world globally through its
contribution to the environment and other
activities, in both its B2C and B2B businesses.
4
EDITORIAL
5
History of Air Conditioning Group
Panasonic starts with a desire to create things of value. As hard
work and dedication results in one innovative product after another,
the fledgling company takes its first steps towards becoming the
electronics giant of today.
1936
First electric Fan
with Automatic
Oscillation (36 cm
table top model).
6
1958
First room air
conditioner launched
for domestic
installation.
Prior to this date, air
conditioners were
large and only for
commercial use.
Panasonic developed
the first compact air
conditioner for
windows; it was
lightweight and easy
to install, improving
the quality of life in
Japanese homes.
1,100 units were sold
in Japan in the first
year, and just two
years later, in 1960,
this figure rose to
230,000.
1973
Panasonic launches
the first highly
efficient air-to-water
heat pump in Japan.
1975
Panasonic becomes
the first Japanese air
conditioner
manufacturer in
Europe.
2008
Etherea new concept
of air conditioning
systems: high
efficiency and high
performances with a
great design. Etherea
also includes a very
innovative air quality
sensor and air
purifier in order to
enjoy healthy air at
home at all times.
2010
New Aquarea.
Panasonic has created
Aquarea, an innovative
new, low-energy
system, designed to
help you enjoy ideal
temperatures and hot
water in your home,
even with extreme
outdoor temperatures.
Aquarea cools or
heats to ensure
maximum comfort.
Aquarea is far cleaner,
safer, cheaper and
environmentally
friendly than
alternatives
using gas, oil and
other electrical
systems.
2011
New Eco i VRF
solution.
The new Panasonic
VRF solution for big
buildings is the most
efficient in the
industry in more
than 74% of
combinations. ECO i
satisfies the most
demanding standards
required by design
offices, architects,
owners and
installers.
2012
New GHP units.
Pansonic’s gasdriven VRF systems
are ideal for projects
where power
restrictions apply. In
2012, Panasonic
extends the Gas Heat
Pump range with a
new GHP line-up,
new GHP G Power
(electricity
production) and the
new Chiller Units.
2013
New ECOi 3-pipes.
The best efficiency
for your building.
Our New 6 Series
3-pipes is achieving
a COP of 4.77 at full
load, and even more
when recovering heat
from the building.
There is no doubt,
Panasonic is
reducing
environmental
impact!
2014
New Aquarea 16kW
T-CAP. Improvements
deliver impressive,
high efficiencies at
low ambient
temperatures. T-CAP
stands for Total
Capacity and is
capable of maintaining
the same nominal
capacity even at -15°C
without the help of an
electric booster heater.
Ideal for retrofit and
commercial
applications.
EDITORIAL
100%
ANASONIC
N 100% P
PRODUCTIO UALIT Y ASSURANCE
SIGN
ND Q
TESTING A ELOPMENT AND DE
V
E
D
&
H
C
RESEAR
ROVIDER
SERVICE P
Panasonic – leading the way in Heating
& Cooling
With more than 30 years of experience, selling to more than 120 countries
around the world, Panasonic is unquestionably one of the leaders in the
heating and cooling sector.
With a diverse network of production and R&D facilities, Panasonic delivers
innovative products incorporating cutting-edge technologies that set the
standard for air conditioners worldwide.
Expanding globally, Panasonic provides superior international products
transcending borders.
100% Panasonic: we control the process
The company is also a world leader in innovation as it has filed more than
91,539 patents to improve its customers’ lives. Moreover, Panasonic is
determined to remain at the forefront of its market. In all, the company has
produced more than 200 million compressors and its products are
manufactured in 294 plants which are located all over the world. You can
be assured of the extremely high quality of Panasonic’s heat pumps.
This wish to excel has made Panasonic the international leader in heating
and turn-key air conditioning solutions for homes, medium-sized buildings
such as offices and restaurants, and large-scale buildings. These offer
maximum effectiveness, comply with the strictest environmental standards
and meet the most avant-garde construction requirements of our time.
At Panasonic we know what a great responsibility it is to install heating
and cooling systems. Because offering you the best solutions in heating
and cooling matters
7
RELIABILITY
FACTS
Reliable comfort comes from reliable technologies
Today, Panasonic air conditioners have earned widespread acclaim throughout the world.
A rugged design ensures that the air conditioner will continue to keep the room comfortable, and operate troublefree for many years. Panasonic believes this is the true value of an air conditioner. And this is why we subject them
to a wide range of stringent tests.
Durability. Long Time Continuous Operation Simulation.
Long-term Durability Test
The air conditioner’s main mission is to provide a level
of durability that allows it to operate stably for years. In
order to achieve this, we conduct an accelerated test
for 10,000 hours of continuous operation. The results of
this test, which is conducted under conditions that are
much more severe than actual operating conditions,
prove the rugged strength of Panasonic air conditioners.
Compressor Disassembly Test
After a test with 10,000 hours of continuous operation,
we remove the compressor from a randomly selected
outdoor unit, disassemble it, then examine the internal
mechanisms and parts for possible failure. Panasonic
air conditioners continue to provide their designed
performance for many years even after prolonged
operation under harsh conditions.
Operating Test in Harsh Conditions
In addition to normal operating conditions, an operating
durability test is conducted in a high-temperature, high
humidity test chamber at a temperature of 55 °C. For
use in cold climates, the test is also conducted in a low
temperature test chamber at -20 °C. This test assures
that the oil inside the compressor will not freeze during
use and interrupt operation.
Checking the oil inside the
compressor under
extremely cold conditions.
8
Waterproof Test
The outdoor unit, which is subject to rain and wind, is
provided with IPX4 waterproof compliance.
Contact sections on printed circuit boards are also
resin-potted to prevent adverse effects caused by an
unlikely exposure to droplets of water.
A resin-potted circuit board.
EDITORIAL
No Breaking. When Dropped onto Sides or Corners.
Shock Resistance
Panasonic simulates impacts, vibrations and other
environmental conditions that air conditioners might be
subjected to during transport. We promise that the quality
and performance at the time of the final product inspection
are unchanged when the product reaches the user’s home.
Drop Test
Even with the large impacts that may occur due to improper handling during
transportation, the product packaging has been strengthened to prevent it
from being damaged. In addition to conventional vertical dropping, more
severe conditions in which the sides or corners hit the floor first are carefully
tested to ensure that the product’s rigidity and shock-absorbing materials
work to prevent problems.
Vibration Test
Preventing damage that would
hinder the product’s performance
due to vibration during transport is
a major role of the packaging.
Panasonic confirms that the
product operates properly even
after applying vibrations in both
horizontal and vertical directions.
Warehouse Storage Test
During distribution, products may
be subjected to extended
warehouse storage under
unfavourable conditions. To
simulate these conditions, we
place a weight equal to a stack of
five product packages on top of the
test package, and leave it in that
condition in a room at a
temperature of 27°C and a
humidity level of 85%. Then, the
product is checked for proper
operation.
Silence. That Does Not Disturb You.
Comfort
Air conditioners should keep each person in the room
comfortable without making their presence known.
They should work totally in the background, using their
strength to create and maintain a relaxing environment. We
build this hidden strength into our air conditioners, and test
them repeatedly from this viewpoint.
Noise Test
The operating noise of the indoor
and outdoor units is measured in
an echo-free chamber. The noise
test verifies that the operating
noise is low enough so that the
product operation will not disturb
daily activities including
conversations and sleep.
Sunshine simulation.
Amenity Test
An actual air conditioner is
operated in a test room that
simulates an ordinary living room.
Conditions such as the amount of
sunlight entering the room from
outside are changed while
measuring a variety of parameters,
such as cooling speed, cooling
efficiency, and temperature and
humidity differences throughout the
room. This makes it possible to
confirm whether the air conditioner
is operating at its designed
performance level under ordinary
conditions.
EMC (Electromagnetic
Compatibility) Test
This test determines whether
electromagnetic waves emitted
during operation are sufficiently
low to prevent adverse effects, i.e.,
electrical noise, on signals such as
TV and radio broadcasts.
Remote Control Dropping Test
Because the remote control is the
main interface between people and
the air conditioner, it is naturally
subjected to frequent impacts such as drops and bumps - when it
is passed from person to person
during normal operation. Panasonic
drops the remote control from a
height of 1.5 metres at various
angles to ensure that no problems
in basic performance will result
from accidental dropping.
Quality. Is at the Core of All Our Manufacturing.
World Standard Quality
Over the years, Panasonic air conditioners have continued to
offer the highest possible quality with the lowest
environmental impact worldwide. Naturally, the fundamental
production principles that are common to all Panasonic
products apply to air conditioners as well. The fact that these
principles actively support every product, rather than simply
serving as slogans, is the result of the endless repetition of
challenges and trial-and-error efforts that are conducted at
our production bases all over the world.
Reliable Parts with Major
Standards Approval
Panasonic air conditioners comply
with all of the major standards that
maintain high reliability in the
countries and regions where they
are marketed. To ensure this, we
conduct a variety of tests to
examine the quality of materials
used in parts.
The strength of the
resin material used in
the propeller fan is
confirmed by the
tension test.
RoHS/REACH Compliant Parts
All parts and materials comply with
RoHS/REACH, Europe’s worldleading environmental regulations.
Stringent inspections of more than
100 materials are conducted to
ensure that no hazardous
substances are included during
parts development.
Sophisticated Production
Process
The air conditioner production line
uses advanced, state-of-the-art
factory automation technologies to
produce products with higher
reliability. Products are efficiently
manufactured with high and
uniform quality.
Eco Activities
Panasonic has set up eco ideas
factories around the globe. While
developing and manufacturing
energy-saving products based on
original environmental
technologies, these factories
reduce CO2 emissions from
manufacturing processes and
conduct regional-based
environmental communication
activities to contribute to both the
global environment and the local
communities that they serve.
9
Panasonic Europe announces Sustainability Declaration
Panasonic establishes new targets for the business’ environmental performance and CSR initiatives
Best Global Green Brand 2013
We were recently awarded Interbrand’s 4th Best Global Green Brand 2013 – the highest of any
consumer electronics brands. This is the result of our commitment to energy efficient products,
reduction in CO2 emissions, kids school ‘eco learning’ programme and much more.
Sustainability Declaration. Berlin, Germany, 4th September 2013
Panasonic Europe announces today its new Sustainability Declaration for Europe and CIS, extending its current initiatives to
ensure all business activities lead to a more sustainable society.
The Sustainability Declaration unites Panasonic’s new brand direction towards ‘A Better Life, A Better World’ with a series of
environment and CSR initiatives contributing to the progress and development of society. Recognising the impact on the
environment and society through its products and practices, Panasonic aims to deliver on specified targets by March 2016.
The European Sustainability Declaration is in accordance with Panasonic’s Global Sustainability Policy, which has been rolled
out globally in recent weeks.
We aim to realize a lifestyle with virtually zero
CO2 emissions throughout the entire home
Solar Power Generator
HIT solar cells achieve maximum output
even on smaller roofs. These solar
modules are 100% emission free, have
no moving parts and produce no noise.
Home AV
Panasonic offers a wide range of
energy saving home equipment to
fulfil a sustainable and comfortable
lifestyle.
Heat Pump
The Aquarea Heat Pump is part
of a new generation of heating
systems that use a renewable,
free energy source: air, to heat
or cool the home and to
produce hot water.
Fuel Cell
The Panasonic Fuel Cell is an energy-creating
device, which generates electricity and heat at
the same time with chemical reaction between
hydrogen extracted from natural gas and
oxygen.
Solar Power Generator
Our mobility space can be connected
to our HIT solar panels – with help of
our storage batteries.
LED Lamps
Expertise gathered over years of
research and development has enabled
Panasonic to provide a renaissance in
energysaving home LED lighting – with
our LED Nostalgic Clear lamp.
Home Appliances
Panasonic is globally committed to develop products
which are environmentally friendly. Panasonic delivers
home appliances such as refrigerators and washing
machines that incorporate the latest energy-efficient
technology.
10
Storage Battery
The battery stores the energy
generated by a combination of
solar power and fuel cells to
ensure a constant supply of
electricity on demand.
EDITORIAL
Exemplary sustainable projects
Fujisawa Sustainable Smart Town
Homes will employ the full range of Panasonic’s
most advanced systems for energy production,
storage and management.
In this project, a new concept and process will be
adopted to build the town by designing spaces
first with a primary focus on services based on
people’s lifestyles and creating an optimal smart
infrastructure. In Fujisawa SST, Panasonic will
offer its unique solutions from an Eco & Smart
perspective. With bringing energy to life for
residents as the town concept, we will provide
services that enhance people’s lives with
photovoltaic power, security, mobility, community,
and healthcare.
The unparalleled town building, where as many as
1,000 families will live, will serve as a new
business model both within Japan and overseas.
Panasonic will provide the project with a variety
of its energy efficient heating and cooling
products, including the Aquarea Air Source Heat
Pump – a super-efficient system for providing
heating and / or cooling facilities, as well as the
production of domestic hot water. These heat
Panasonic joins Smart Electric Lyon
pumps are especially equipped with connectivity
consortium
solutions from Panasonic to ensure the systems
What is Smart Electric Lyon?
are easy to use, and collect the vital, accurate
Smart Electric Lyon is a project that looks at
data. The company will also integrate other home
electricity consumption as a key part of the
building energy solutions of tomorrow. The project equipment solutions such as LED white lighting
products to optimize the overall energy
aims to develop a wide range of innovative
management of the project’s properties.
facilities and services through real-life
This project is particularly apt for Panasonic, as
experiments to test energy saving technologies
heating and hot water occupy a prominent place
and to measure how consumers can control
in household energy consumption. Panasonic
energy consumption.
plans to make its European and French resources
This experiment, unprecedented in scale in
Europe, will be conducted for four years in more available for Smart Electric Lyon. The company
than 25,000 homes, businesses and communities has involved for the project a dedicated and
experienced R&D team from Panasonic’s European
of Grand Lyon. It is intended to test innovative
technical centre in Frankfurt.
solutions that will consume less and better.
The connected home of the future
11
PRO Club: the professional website of Panasonic
Panasonic has an impressive range of support services for
designers, specifiers, engineers and distributors working in the
heating and cooling markets.
Panasonic announces a new initiative for all professionals involved in the
heating and cooling business - the Panasonic PRO Club
(www.panasonicproclub.com). Panasonic PRO Club is the online tool which
makes your life easier! You just have to register and a lot of functionalities
are freely available to you, where ever you are, from your computer or
smart phone!
· Print catalogues with your logo and your address
· Download the latest Aquarea designer to define your system and
select the good Aquarea Heat pump.
· Calculate the specs of the Aquarea Air fan coil based on the
parameters of your system
· Get Documents of conformity and all other documents you may
need
· Download all the service manuals, end user manuals and
installation manuals
· Know what to do with error codes
· Find out about the latest news first
· Register for training and take part in online training
www.panasonicproclub.com
or connect simply with your smartphone to the proclub using
this QR:
12
Highlighted Features
· Extensive library of resources
· Tools & Apps for end users. Check availability in your country:
- My Home: sizing wizard for domestic and A2W range
- My Project: Contact form to Panasonic team
- iFinder: Lists of installers displayed by postcode
· Special offers & promotions
· Training PRO Academy
· Catalogues (Commercial documentation)
· Marketing (Images in high resolution, advertisements, deco guidelines)
· Tools (Professional software, sizing tools...)
NEW Highlighted Features
· NEW! Installers customize leaflets in PDF format with their logo &
contact details
· NEW! Energy label generator. Download energy labels of any device in PDF
format
· NEW! Heating calculator demand
· NEW! Noise calculator for outdoor unit
· NEW! Aquarea Radiator calculator
· NEW! Error Code Search by error code or unit ref. Compatible with
smartphone and tablet computer
· NEW! Revit / CAD Images / Spec texts
· NEW! Access to Pananet, online library of technical documentation
· NEW! Download Documents of Conformity and other Certifications
· NEW! Commissioning online
EDITORIAL
NEW! Easy download Panasonic service documentation and brochures
Panasonic PRO Club is fully compatible with Tablet computer and
smartphone
NEW! Customize leaflets with your logo & contact details. Save and print the PDF
NEW! Energy label generator. Download Energy labels of any device in PDF format
NEW! Error Code on your smartphone and your PC: Search by error code or model
reference. Online version + downloadable version for offline use
The Panasonic PRO Academy opens its doors
Panasonic takes its responsibility to its distributors, specifiers and
installers seriously and has developed a comprehensive Training
Programme. The Panasonic Pro-Academy encompasses the traditional
hands-on approach, as well as embracing today’s technology to offer an
eLearning facility available 24 hours, 7 days a week!
New training courses cover three levels. Design, installation, and
commissioning & trouble-shooting. Training courses include:
· Domestic applications Air to Air
· Aquarea air source heat pumps
· VRF ECOi
The courses are offered on site at Panasonic’s premises across Europe as
well as via the Panasonic ProClub eLearning site. The Training Centres
display Panasonic’s latest product range and give delegates an opportunity
to get hands-on experience with the latest controllers, indoor and outdoor
units from the VRF ECOi, Etherea, GHP and Aquarea ranges.
13
Aquarea Designer
Panasonic provides bespoke software helping system designers,
installers and dealers to very quickly design and size systems,
create wiring diagrams and issue bills of quantities at the push of a
button.
This program allows HVAC designers, installers and distributors to identify
the correct heat pump for a particular application from Panasonic’s Aquarea
range, calculate the savings compared to other heat sources and very
quickly calculate CO2 emissions.
Using Panasonic’s Aquarea Designer, projects can be developed simply and
easily, by either using the Quick Design or Expert Design options. Each
allows the user to build up the project data in a simple step-by-step
process and choose to output reports (in either Quick or Large formats) as
HTML files or as print-outs. To create these useful reports, project data is
input, including:
· Heated area
· Heating requirement
· Heating flow and return temperatures
· Climate data (from a simple drop-down menu) including outdoor
temperature
· Type of hot water tank, storage capacity and hot water target
temperature.
14
AQUAREA
Aquarea Designer also means saving
Aquarea Designer will calculate the project’s energy costs in terms of hot
water, heating and pumping. It will show the equipment running times and
calculate the COP (coefficient of performance). It then allows the designer to
show clients a comparison with other equipment options such as heating by
conventional gas-fired boilers, oil systems, wood, standard electric heating
and electric night storage heaters. This compares running costs, initial
investment costs and maintenance costs. The comparison can also be made
for CO2 emissions and savings.
PRO Club: the professional website of Panasonic
Panasonic announces a new initiative for all professionals involved in the
heating and cooling business - the Panasonic PRO Club
(www.panasonicproclub.com). This exciting new portal provides
distributors, installers, engineers and specifiers with a direct
communication channel with one of the industry’s major manufacturers.
The website contains a wealth of information from the latest versions of
Panasonic’s Aquarea and Etherea Design Software, to Technical
Documentation, Catalogues and Images for the company’s wide range of
heating and cooling systems - all in an easy to navigate and use website.
Also, registered users will be able to access news regarding special
promotions and take advantage of these offers, as well as access helpful
business advice such as ideas and guidelines for showroom decoration or
van livery featuring Panasonic logos and display material.
Donwload on www.panasonicproclub.com
or connect simply with your smartphone to the proclub using this QR:
15
Inverter+ System.
The A Inverter+ system provides energy
savings of up to 30% compared to non
Inverter models. Both you, and nature,
wins!
High
efficiency
heating
Environmentally
friendly
refrigerant
R410A / R407C
Down to
-20 ºC in
heating mode
OUTDOOR
TEMPERATURE
Up to -20°C In Heating Mode.
The Heat Pumps works in heat pump mode
with an outdoor temperature as low as
-20°C.
Renovation.
Our Aquarea heat pumps can be connected
to an existing or new boiler for optimum
comfort even at very low outdoor
temperatures.
Boiler
connection
RETROFIT
Solar Kit.
For even greater efficiency, our Aquarea
heat pumps can be connected to
photovoltaic solar panels with an optional
kit.
Solar
panels
connection
SOLAR KIT
DHW
With Aquarea you can also heat your
domestic hot water at a very low cost with
the optional hot water cylinder.
Domestic
hot water
DHW
Connectivity.
The communication port is integrated into
the indoor unit and provides easy
connection to, and control of, your
Panasonic heat pump to your home or
building management system.
Easy
control
by BMS
CONNECTIVITY
OP
TIO
N
AL
Internet
Control
Ready
Refrigerant R410A / R407C.
R410A / R407C offers optimal performance
and involves no environmental cost since
it does not harm the ozone layer.
INTERNET CONTROL
5 year
compressor
warranty
Internet Control is a next generation
system providing a user-friendly remote
control of air conditioning or heat pump
units from everywhere, using a simple
Android or iOS smartphone, tablet or PC
via internet.
Aquarea’s new Air To Water Heat Pump for residential applications
Offering capacities from 3kW all the way through to 16kW, the Aquarea Heat Pump Range is the
widest on the market, ensuring a system is available, whatever your heating and cooling needs.
Suitable for new build and refurbishment projects, the systems are cost-effective and
environmentally friendly.
5 Years Warranty.
We guarantee the compressors in the
entire range for five years.
* Not all products certified. As the certification process is on-going and the list
of certified products constantly changing, please check for latest details on
the official websites.
ehpa
16
NEW
AQUAREA
SEASONAL
EFFICIENCY
NEW AQUAREA
AIR TO WATER HEAT PUMP
Panasonic’s new Aquarea Air To Water system can work in outdoor temperature even at -20°C
Panasonic’s new Aquarea system, based on high-efficiency heat pump technology, not only heats your home
and hot water, but also cools your home in summer with incredible operating performance. This creates
perfect comfort whatever the weather conditions, even at outdoor temperatures as low as -20°C.
Panasonic new heat pumps are designed in response to the new demand for low consumption housing, with
high efficiency and low running costs.
17
SEASONAL
EFFICIENCY
A
class pump
Aquarea the best seasonal efficiency
Panasonic’s new Aquarea air to water system can work in outdoor
temperature even at -20°C
Panasonic’s new Aquarea system, based on high-efficiency heat pump
technology, not only heats your home and hot water, but also cools your
home in summer with incredible operating performance. This creates
perfect comfort whatever the weather conditions, even at outdoor
temperatures as low as -20°C. Panasonic new heat pumps are designed in
response to the new demand for low consumption housing, with high
efficiency and low running costs.
Impressive Energy Savings
Panasonic’s Aquarea Heat Pump provides savings of up to 80% on heating
expenses compared to electrical heaters.
A
class pump
18
The Panasonic Aquarea Heat Pumps are designed and
produced by Panasonic and not by other companies.
AQUAREA
Up to 80% energy savings*
“We expect to save around 1,000 € a year on fuel costs
and we’ve been able to get rid of a large ugly oil tank
in the garden thanks to the new Aquarea.”
Aquarea Customer, Surrey¹
At the forefront of energy innovation, Aquarea is resolutely positioned as a
“green” heating and air-conditioning system. Aquarea is part of a new
generation of heating and air-conditioning systems that use a renewable,
free energy source – the air – to heat or cool the home and to produce hot
water. The Aquarea heat pump is a much more flexible and cost-effective
alternative to a traditional fossil fuel boiler.
1) Information provided by Aquarea customer, August 2012.
Air source heat pumps – Quick facts
· Provides sustainable heating, cooling and hot water for your home
· 30%-40% reduction in annual energy bills
· Ideal for properties without access to mains gas
· Operates even in freezing temperatures (-20°C).
· Externally positioned saving valuable internal living space
· Proven technology from Panasonic and already well established in other
EU countries
Why air source heat pumps?
· Reduced heating bills and maintenance costs
· Savings of up to Euro 1,000 a year are possible
· Reduce your carbon footprint
· Simple to integrate into most heating systems
· Energy efficient alternative to oil, LPG and electric systems
· Highly compatible with other energy efficient energy sources eg solar
panels
“Green” High-efficiency heating with Panasonic’s new Air to Water
Heat Pump Systems
Panasonic’s Aquarea Heat Pump provides savings of up to 80% on heating
expenses compared to electrical heaters. For example, the Aquarea 5kW
system has a COP of 5,08. This is 4,08 more than a conventional electrical
heating system which has a maximum COP of 1. This is equivalent to an
80%* saving. Consumption can be further reduced by connecting
photovoltaic solar panels to the Aquarea system.
GAS
BOILER
OIL
BOILER
AQUAREA
UP TO 80%
ENERGY SAVINGS*
ELECTRICAL
HEATING
80%
0,803
kW
1kW
0,9kW
1kW
0,9kW
1kW
1kW
RENEWABLE
ENERGY
GAS
HEAT
OIL
HEAT
ELECTRICITY
HEAT
0,197kW
Other heating systems
POWER INPUT / ENERGY CONSUMPTION
POWER OUTPUT / HEATING CAPACITY (kW)
ELECTRICITY
OUTDOOR
ENERGY
1kW
HEAT
20%
ELECTRICITY
Aquarea
* Up to 80% of the heat produced by a heat pump is free, since it comes from the outdoor air. Rating conditions: Heating: Inside air temperature: 20°C Dry Bulb /
Outside air temperature: 7°C Dry Bulb / 6°C Wet Bulb. Conditions : Water input temperature: 30°C Water output temperature: 35°C
19
Panasonic has designed a
completely new line-up to
offer the best to our
customers
6
There are several types of heat pump
available:
· The Mono-Bloc system: This only has an
outdoor unit. The installation doesn’t require a
refrigerated connection and is only connected
to the heating and/or hot water.
· The Bi-Bloc system: The system, separate
indoor and outdoor units, connects to the
heating and/or hot water system.
A wide range from 3 to 16kW, Single and Three
Phase, Mono-Bloc and Bi-Bloc. 3 Versions:
· Aquarea High Performance: From 3 to 16kW
· Aquarea T-CAP: From 9 to 16kW
· Aquarea HT: From 9 to 12kW
5
2
3
1a
1b
Aquarea outdoor
Bi-Bloc option
20
4
AQUAREA
Three Aquarea solutions
A
5.08 COP
A
class pump
high efficiency
class pump
1
AQUAREA
HIGH PERFORMANCE
Aquarea High Performance for low
consumption houses. From 3 to 16kW
For a house with low temperature radiators or
under-floor heating, our high performance
Aquarea HP is a good solution. This solution
can work as a stand-alone unit or can be
combined with an existing gas- or oil-fired
heating system depending on requirements.
This new solution is ideal for low consumption
homes.
1) For WH-MDC05F3E5.
1b
100%
Output water
65 ºC
capacity
at -15 ºC
HIGH TEMP
HEAT PUMP
AQUAREA T-CAP
Aquarea T-CAP. From 9 to 16kW
If the most important aspect is to maintain
nominal heating capacities even at
temperatures as low as -7°C or -15°C, select
the Aquarea T-CAP. This ensures that there is
always enough capacity to heat the house
without help from an external boiler – even at
extremely low temperatures.
Aquarea T-CAP always has high efficiency and
high heating capacity even at extremely low
temperatures. With Aquarea T-CAP, you can
always enjoy high savings.
Aquarea HT. From 9 to 12kW
For a house with traditional high-temperature
radiators (such as cast iron radiators), the
Aquarea HT Solution is the most appropriate as
the Aquarea HT can work in output water
temperatures of 65°C even at outdoor
temperatures as low as -20°C.
Aquarea HT is able to deliver hot water to 65°C
with the Heat Pump alone.
2
3
Optional
Optional
1a
Aquarea outdoor air source heat pumps
Panasonic has developed an extensive range of air-to-water heat
pumps designed to efficiently convert free air into sustainable
heating and hot water. Fitted externally to your home and
designed to operate in all year round weather conditions (-20°C),
it’s the smart alternative to oil, LPG and electric heating systems.
Aquarea Heat Pump Manager
This new generation of smart controllers for eco-efficient heating,
features our versatile stand-alone controller not only for our heat
pump systems, but also your gas, oil boiler and all other devices
installed on your heating system.
Heating control App for smart phone, tablet or computer
The heating control App allows you to control the heating and hot
water system via your smart phone, tablet or computer with ease,
whether at home or away.
The heat pump can be also connected to house management
system using KNX, Modbus or Zig Bee interfaces.
4
5
6
Optional
Optional
Optional
Super High Efficiency: PAW-TE20/30/50E3HI
· High efficient tank solution: specially designed to improve the
efficiency of the sanitary hot water production.
· HI lineup:
- low energy losses
- high exchange surface for high efficiency and short time to heat
up the water
High efficient radiators for heating and cooling
· High efficient radiators working with water at 35°C.
· No need for two kits if both floor heating and radiators are required.
· As the product is efficient, it opens the possibility to also
provide cooling while still meeting construction requirements.
Panasonic offers a cooling mode within its heat pump range
for low consumption homes
Heat Pump + HIT Photovoltaic solar panel
Photovoltaic solar panels: the best solution for big savings.
Combining photovoltaic solar panels with your heat pump can help
to further reduce your electrical consumption and CO2 emissions.
Additionally, with the unique HIT photovoltaic solar panel technology
from Panasonic, you can produce more electricity per square metre,
helping you to increase your energy savings still further.
21
For new s
ation
l
l
a
t
s
n
i
and low
tion
p
m
u
s
n
co
homes
5.08 COP
high efficiency
AQUAREA
HIGH PERFORMANCE
area 5kW
New Aqu -Bloc
Mono
New High Performance for low consumption homes.
Maximum savings, maximum efficiency, minimum CO2 emissions, minimum of space.
Panasonic has designed the new Aquarea Bi-Bloc and Mono-Bloc heat pumps for homes which have
high performance requirements.
Whatever the weather, Aquarea can work even at -20 °C! The New Aquarea is easy to install on new or
existing installations, in all types of properties.
New High Performance helps you to meet strict building
requirements and reduce building costs
The heating and production of hot water have a very important impact on the energy consumption of a
house. Efficient Panasonic heat pumps can help to significantly reduce the energy consumption of the
house.
Total energy consumption of a conventional house, compared to the energy consumption with Panasonic heat pumps
Total energy consumption of a
conventional house¹
Energy consumption with
Panasonic heat pumps²
Heating
26%
26%
47%
27%
22
38%
SAVINGS
24%
Sanitary Hot Water
Domestic Appliances³
12%
1. Source: IDEA, European values 2010. Consumption
of a conventional house of 80 kWh/(m².year).
2. Source: Panasonic, RT2012 simulation, house of 50
kWh/(m².year) per year, equipped by Panasonic
heat pump. 3. Eg. Fridge telephone, oven,…
NEW
AQUAREA
Key points of the line-up
· A-Class pump significantly reduces the energy consumption
Equivalent to
100 €/year
saving*
· A Class pump adapts water pressure according to demand, reducing
energy consumption, noise on the valves, and makes installation easy.
· No Backup heater needed to maintain the capacity at -15°C, high
efficiency guaranteed even at -15°C
· Many new remote control functions added:
Auto mode, holiday mode, show power consumption
HIGH PERFORMANCE PUMPS ARE ALSO HIGHLY EFFICIENT
COP
75 W
Standard
pumps
47 W
A class pump
New A class pump with Constant water flow (Dynamic pump
control) for 5kW Mono-Bloc
Comparison of energy consumption - Standard pumps vs A class pump
* Based on German market: Assuming Standard pump may vary depending on consumption and energy cost.
HEATING CAPACITY
6
6
5
5
4
4
3
3
2
2
1
1
0
0
WH-MDC05F3E5
At -15°C*
-5 db(A)²
50
city n
-15°C
30
20
NORMAL MODE
QUIET MODE²
1. Sound pressure measured at 1 m from
the outdoor unit and at 1.5 m height.
2. At standard condition working at
heating capacity at +7°C (heating water
at 35°C) for two fans outdoor units. For
one fan outdoor units, night mode
reduction is 3dB(A).
5,0kW
eede
d to h
· High flexibility with
Panasonic Inverter
compressors
· High performance
even at part load
eat t
he ho
use
-7°C
+2°C
+7°C
Outdoor temperature
8,0kW
5,0kW
Panasonic heat pump does
not need heater as the
capacity is maintained
Capacity of other heat pumps need to be
higher than the Panasonic heat pumps
5kW WH-MDC05F3E5
p
t pum
r hea
Othe
Other Heat pumps needs
electrical heater to cover
the needs of the house
40
* (heating water at 35°C)
Capacity is stable even
at -15°C, no need to
oversize the heat pump
Capa
Capacity inkW
NOISE LEVEL
At +7°C*
5kW WH-MDC05F3E5
Special attention has been given to noise levels - Panasonic created
a night mode to reduce the noise when it’s needed.
db(A)¹
At +2°C*
5,0kW
Capacity inkW
With a Panasonic heat pump, there is no need to oversize the heat
pump to reach the required capacity at low temperatures.
· Dedicated software for low consumption houses which allows the heat
pump to produce hot water at 20°C. This is needed during the seasons,
when a little heating is required
· No need for an additional expansion vessel, as the unit already has a 6l
expansion vessel
· No buffer tank required as the Panasonic heat pump has an inverter
compressor which can regulate the capacity. (Please check on the service
manual the minimum volume of water needed on the circuit)
· 3kW electrical heater is included on the heat pump
· Panasonic heat pumps can work in outdoor temperatures as low as -20°C
and guarantee the capacity without backup heating down to -15°C
· Panasonic heat pumps are very quiet and have a night mode program for
even lower noise. See noise calculator on www.panasonicproclub.com
WH-MDC05F3E5
At -7°C*
-15°C
Capa
city n
eede
d to h
Bad performance
to big capacity
5,0kW
· High flexibility with
Panasonic Inverter
compressors
· High performance
even at part load
eat t
he ho
-7°C
use
+2°C
+7°C
Outdoor temperature
23
AP FOR
C
T
w
e
N
ly low
e
m
e
tr
x
e
ures
rat
e
p
m
te
100%
capacity
at -15 ºC
AQUAREA T-CAP
area
New Aqu loc
B
16kW BI-
New T-CAP for extremely low temperatures. Install
A Class pump: Industry top class energy-saving!
The whole T-CAP line-up can replace old gas or oil boilers, and in a new application
with under floor heating, low temperature radiators or even fan-coil heaters. This
range can also be connected to a solar kit in order to increase efficiency and
minimize the impact on the ecosystem. Finally, it is possible to connect a thermostat
for even better heating or cooling control and management.
· T-CAP stands for Total Capacity. This line-up is able to maintain the same nominal
capacity even at -15°C without the help of an electrical booster heater.
· High heating capacity even at low ambient temperatures.
· Maintains capacity of 16 kW until -15°C outdoor temperature. Adding many new
functions: Auto mode, Holiday mode, power consumption display.
The New T-CAP range has extended with the addition of the 16kW pump
The new 16kW maintains full capacity of 16kW even at outdoor temperatures down
to -15°C.
The 16kW fits perfectly to retrofit houses, as well as to commercial applications to
heat and cool the applications and also to provide sanitary hot water.
24
NEW
AQUAREA
New Aquarea T-CAP. High capacity improvement at low
ambient & high efficiency
Best efficiency compared to other heating Efficiency
systems
Enhance larger capacity (16kW)
More Energy saving with A Class pump.
Adding new functions
Auto mode, Holiday mode, Displays power consumption, New de-ice control,
Concrete Dry mode, Lock cooling mode and Pump speed control.
Panasonic heat pumps have a maximum COP of 4.85 at + 7 °C which
makes them much more efficient than fossil fuel fired boilers, gas boilers
and electrical heaters.
5
Water 35 ºC
4.85
Applications
4
3.07
For commercial
applications
For heating and
cooling mode
For heating and
sanitary hot water
Wide range of capacities
now covered - from 9kW to
45kW with the Heat Pump
Manager. Also you are able
to connect up to five heat
pumps on cascade with the
Heat Pump Manager.
The 16kW model is able to
heat the water at 55°C and
can work even when the
temperature is as low as
-20°C. Cooling operation
can be activated on the
remote control to cool
water up to +5°C.
Efficient domestic hot
water tanks allow large
storage for high
consumption of hot water
(for example Jacuzzi or
bathtub). All our tanks
have an anti-legionella
protection with a backup
heater of 3kW.
2
1
0
Fuel fired boiler
Aquarea T-CAP maintains the nominal capacity until -15°C
The T-CAP line-up is able to maintain the same nominal capacity even at
-15°C without the help of an electrical booster heater. T-CAP is also able
to provide extremely high efficiencies, whatever the outside or the water
temperature. Panasonic has now extended the range with the new three
phase 16kW.
kW
Heating capacity
Gas boiler
Panasonic T-CAP 9 kW
at +7°C
Panasonic T-CAP 9 kW
at -7°C
· Backup heater capacity can be selected (3/6/9kW)
· Cooling mode activation possible by software*
* This activation can only be done by service partner or installer
PANASONIC T-CAP
Capacity is stable even at
-15°C, no need to oversize
the heat pump
16kW
16kW
16kW T-CAP
Capacity in kW
A Class pump. More Energy saving
2.11
Water 55 ºC
Replace easily expensive
gas or oil boilers for high
efficient 16kW T-CAP or
manage bivalent
installations (heat pump
and existing gas or oil
boiler) with the Heat Pump
Manager.
Further information on:
www.panasonicproclub.
com
2.85
Water 35 ºC
For retrofit houses
Water 55 ºC
3
Capa
city n
18
· High flexibility with
Panasonic Inverter
compressors
· High performance
even at part load
eede
d to h
eat th
e hou
16
14
-15°C
se
-7°C
+2°C
+7°C
Outdoor temperature
12
COMPARISON WITH COMPETITORS
18kW
10
8
16kW
Panasonic heat pump does
not need heater as the
capacity is maintained
4
p
t pum
r hea
Othe
Other Heat pumps need
electrical heater to cover
the demand of the house
2
Bad performance to
big capacity
16kW T-CAP
Capacity in kW
6
Capacity of other heat pumps need to be
higher than the Panasonic heat pumps
Capa
city n
eede
d to h
0
+7°C
+2°C
-7°C
eat th
-15°C
e hou
se
Outdoor temperature (heating water at 35°C)
T-CAP 16kW
High connectivity 16kW
-15°C
-7°C
+2°C
+7°C
Outdoor temperature
25
HT
AQUAREA R
FO
SOLUTION °C
65
RETROFIT
Output water
65 ºC
HIGH TEMP
HEAT PUMP
Aquarea HT ideal for retrofit: green energy
source works with existing radiators
Replace a traditional heating source (such as oil or gas) with Aquarea HT,
but keep existing old style radiators for minimum disruption to the home.
From 9 to 12kW. For a house with traditional high-temperature radiators
(such as cast iron radiators), the Aquarea HT Solution is the most
appropriate as the Aquarea HT provides output water temperatures of 65°C
even at outdoor temperatures as low as -15°C. Aquarea HT is able to
deliver hot water to 65°C with the Heat Pump alone.
Panasonic Aquarea HT is super efficient even at low temperature.
Heating Capacity of a 9 kW HT (WH-SHF09F3E5)
COP Coefficient of Performance
kW
COP
9
5
8
4
7
6
3
5
4
2
3
2
1
1
0
0
+7°C
+2°C
-7°C
-15°C
+7°C
Heating capacity of a 9 kW HT
Water 35 ºC
26
Water 55 ºC
+2°C
-7°C
-15°C
Heating capacity of a 9 kW HT
Water 65 ºC
Water 35 ºC
Water 55 ºC
Water 65 ºC
AQUAREA
Panasonic Aquarea HT is super
efficient even at low temperature
Aquarea HT: High savings and low CO2
The results of replacing traditional heating systems with Aquarea HT are
clear: lowest running cost and lowest CO2 emissions. Panasonic heat
pumps are much more efficient than gas boilers and help you to reach your
house energy targets easier.
Yearly savings with Aquarea HT
Euro/Year
Running Costs*
2000
1500
Smart Bivalent operation
Thanks to Aquarea HPM (Heat Pump
Manager), it is possible to combine
different heat sources and use the most
appropriate source, depending on user’s
preferences. This smart control will
decide which is the best source to use anytime.
Thus, if it is necessary to combine gas heater, oil with heat pump, Aquarea
HPM is simply the best solution.
Heat Pump + Boiler Management with DHW with
PAW-HPM12ZONELCD-U
1000
500
0
Panasonic Heat Pump
Oil
Gas
* For a 170 m² house and 40 W/m² energy losses in central Europe Conditions, outside minimum conditions -10°C.
Easy installation
Air source heat pumps are simple to install. They do not require a chimney,
gas connection nor oil tank. All that is required is a standard power supply
connection. Aquarea heat pumps are also quick to start up.
New DHW Tank with buffer Tank PAW-TD20B8E3-NDS
Designed for retrofit applications, the new DHW 200l tank with a 80l buffer
tank is particularly suitable for fast integration on an existing installation.
Panasonic has developed a New tank with 80l Buffer tank and 200l Sanitary
hot water cylinder. This tank includes a 3-way valve and an A Class pump.
Easy to install, nice looking, high efficiency for DHW production and for
heating.
27
L
OR RETAI
F
N
O
I
T
U
SOL
TAURANT
S
E
R
D
N
A
PACIT Y
A
C
W
K
0
8
Aquarea commercial solutions for best savings
AREA
NEW AQU LOC
B
16KW BI-
Efficient Panasonic heat pumps can help to significantly reduce the energy consumption of your
business.
Recent improvements to air source heat pump technology, including compact single unit systems,
can provide an ideal housing and commercial solution. They offer space saving, energy-efficient
heating and can be easily adapted for installation in flats, houses and commercial premises.
And for businesses producing heat, such as restaurants, installing an Aquarea heat pump system
can also use this wasted heat to improve energy efficiency further.
“Green” High-efficiency heating with Panasonic’s new Air to Water Heat Pump Systems
Panasonic’s Aquarea Heat Pump provides savings of up to 80% on heating expenses compared to
electrical heaters. For example, the Aquarea 5kW system has a COP of 5,08. This is 4,08 more
than a conventional electrical heating system which has a maximum COP of 1. This is equivalent
to a 80%* saving. Consumption can be further reduced by connecting photovoltaic solar panels to
the Aquarea system.
AQUAREA
UP TO 80%
ENERGY SAVINGS*
GAS
BOILER
OIL
BOILER
ELECTRICAL
HEATING
80%
0,803
kW
1kW
0,9kW
1kW
0,9kW
1kW
1kW
RENEWABLE
ENERGY
GAS
HEAT
OIL
HEAT
ELECTRICITY
HEAT
0,197kW
Other heating systems
POWER INPUT / ENERGY CONSUMPTION
POWER OUTPUT / HEATING CAPACITY (kW)
28
ELECTRICITY
OUTDOOR
ENERGY
1kW
HEAT
20%
ELECTRICITY
Aquarea
* Up to 80% of the heat produced by a heat pump is free, since it comes from the outdoor air. Rating conditions: Heating: Inside air temperature: 20°C Dry Bulb / Outside air temperature: 7°C Dry Bulb / 6°C
Wet Bulb. Conditions : Water input temperature: 30°C Water output temperature: 35°C
AQUAREA
By flexible with your water
system
Easy connection to existing system
· Fan Coils
· Floor Heating
· 4 way and 2 way convectors
· Domestic hot water tanks
Air Curtain
Convectors
HPM to control the 4
heat pumps on cascade
mode*
Key points:
· High efficiency
· Very good part load management
· Cascade management for higher
durability of the system
High Efficiency
Aquarea Hidrokit
Supermarket with Aquarea
Heat pump technology is scalable, meaning that it can be
installed in buildings of varying sizes, offering both small- and
large-scale heating solutions. The technology is also
environmentally friendly when compared to existing
technologies, offering demonstrable energy-use and emissions
savings and in most cases; will deliver operational cost
savings when compared with fossil fuel alternatives.
4 Aquarea T-Cap
Heat Pump 16kW
on cascade mode
Super High Efficiency Tanks
From 200L to 500L for domestic
hot water
Buffer Tank of 1000 l
* 1 HPM can control 3 HP, on this case 2 HPM are needed
Key points:
· Produce hot water efficiency
· Fast return of investment
· Easy control
· Cascade management for higher durability
of the system
High Efficiency Aquarea Air
Radiators
32% more efficient than
standard radiators
HPM to control the 5
heat pumps on cascade
mode*
Air Curtain
High Efficiency
Aquarea Hidrokit
Restaurant with Aquarea
If you look for savings on you business, Aquarea is the right choice!
Ideal for heating, cooling and for production of big quantities of hot
water at 65 degres, Aquarea have a extremely quick return on
investment and a low CO2 footprint.
5 Aquarea T-Cap
Heat Pump 16kW on
cascade mode
Buffer Tank of 1000 l
Super High Efficiency Tanks
From 200L to 500L for domestic hot water
* 1 HPM can control 3 HP, on this case 2 HPM are needed
29
N ONE
I
L
L
A
W
NE
AND
COMPACT STALL
IN
EASY TO
1
New All in one*
Highly efficient solution
2
Easy installation
3
A class pump
4
200l Tank included
5
Easy integration of the
HPM remote control
10 YEARS OF
TY
A
W RRAN LESS
IN
A
T
S
THE
NK
STEEL TA
New All in One hydromodule + 200l tank
Panasonic has developed a highly efficient solution, easy to
install.
Furthermore, Panasonic has developed a range of controllers
which allows the control of 2 heating zones, bivalent and
cascade systems.
Line up
3, 5, 7, 9kW with 12, 14, 16 kW Single Phase and 9, 12, 14,
16kW Three Phase.
*Preliminary design. Significant changes may occur.
Aquarea All in One Bi-Bloc (Inverter)
HIGH PERFORMANCE 3kW
T-CAP
30
5kW
7kW
9kW
9kW
12kW
12kW
14kW
16kW
16kW
AQUAREA
High efficiency solution
The best of Panasonic:
· Best stainless steel tank with high insulation to reduce energy losses
· High exchange surface to increase efficiency
· Best performing Aquarea hydraulic module to heat the water.
Connectivity Possibilities
3 Remote controls can be installed:
· New Remote control. New function for customer:
- Auto Mode for Heating and Cooling mode
- How to show Energy Consumption
- How to set Holiday Mode
· Heat pump Manager for more then 600 installations possible (as 2 zone
control, Bivalent, etc.)
· Heat pump Manager with touch screen LCD.
All In One Tank+indoor unit
WH-ADC0309G3E5
Outdoor unit connection
WH-UD03EE5
WH-UD05EE5
WH-UD07FE5
WH-UD09FE5
WH-UD12FE5
WH-UD14FE5
WH-UD16FE5
WH-UX09FE5
WH-UX12FE5
WH-UD09FE8
WH-UD12FE8
WH-UD14FE8
WH-UD16FE8
WH-UX09FE8
WH-UX12FE8
WH-UX16FE8
WH-ADC1216G6E5
WH-ADC0916G9E8
3 Remote controls can be installed*
New
Remote
control
External touch Heat Pump
display available Manager
with HPM
(HPM)
Pressure relief valve
Purge
Pressure gauge
Expansion
vessel 10l
Electrical heater
A class pump
with 7 speeds
Electrical box with
RCCB
200l tank with
high insultation
Pipings to the heating
system and tank
15cm reserved to
install pipings
* Preliminary design. Significant changes may occur.
Easy installation
The pipings are sited on the bottom of the heat pump to make the
installation easy and invisible.
A 15cm gap under the unit provides space to connect the pipes.
To make the installation even easier, a piping kit is available in order to pre
mount the guide and fix it on the wall during the construction phase of the
house.
Pippings
Protection to
cover the
space for a
nice
integration
7cm
separation
cover to hide
the pipings.
Flexible
pipes as
accessories
1 Flexible piping +
Flexible
pipes as
accessories
2 Wall separation
Accessories
Flexible piping kit with pre mounted element. PAW-FP-WMP-1: Flexible
pipings and wall mounting plate for all in one.
1” for heating x2
5/8” for water x2
Mounting system
31
AQUAREA
NEW REM
MOTE
CONTROL
New remote control. New features
New Remocon changing point
For 2014, Panasonic has introduced a new remote controller to improve
performance, enhance comfort and deliver maximum savings.
Better user interface:
1. Adding Holiday Mode
2. Adding Power Consumption
· Floor heating concrete dry mode
· How to Lock Cool Mode
· Class A Pump management with 7 speeds
Floor heating concrete dry mode: Allows slow increase in temperature
of floor heating via software.
3
1
2
4
LCD display:
1. Expand LCD display to show mode on
left and right side
2. Adding AUTO mode and remove
defrost display (using heat blink)
3. Change not available into EXT SW OFF
4. Adding kWh and Hr
New function for installer
Temperature
1
6
5
6
Button:
5. Adding holiday button
6. Change force and error reset position
New function for end user
· Auto Mode for Heating and Cooling mode
· Show Energy Consumption
· Set Holiday Mode
· 1 stage for 1 day (maximum 99 stages)
· Min 25°C to 55°C
Day
Heating and Cooling Mode: Authorized service partner or Authorized
installer can enable the cooling mode through a special operation via the
remote controller on site.
Pump with 7 speeds: Pump speed can be selected on the remote control.
Auto Mode: Automatically changes from
heating to cooling depending on outdoor
temperature.
Energy Consumption: Displays the heat
pump’s energy consumption, split by heating,
cooling and domestic hot water, and shows
total consumption figure.
Holiday Mode: Enables the system to
resume at the preset temperature after your
holiday.
32
AQUAREA
Heating feed R1 1/4
New indoor unit design
· New A-class pump with 7 speeds
· Expansion vessel of 10L
· Selectable back-up heater (3/6/9kW)
Wire inlet
Heating return R1 1/4
Drainage
Gas refrigerant connection 5/8
Liquid refrigerant
connection 1/4 -3/8
Pressure relief valve
Flow switch
ANSION
· 10l EXP EL
VESS
ELECTRIC
· 3/6/9KW ENT
ELEM
S PUMP
· A CL AS
Automatic air purge
Water plate heat
exchanger
Expansion vessel 10l1)
Heater assembly 3/6/9kW
selectable on the remote
control2)
Water pump
High efficiency pump
1) 6 l for the 3kW, 5kW and 6kW.
2) 3kW for 7 and 9kW, 6kW for 12, 14, 16kW Single Phase, 9kW for 12, 14, 16kW Three Phase.
Inverter+ compressor for even greater efficiency
Panasonic has clearly demonstrated it status as leaders in this field with
over 200 million compressors supplied and the excellent quality and
reliability of its heat pumps. With a Panasonic Inverter+ compressor, you
can save up to 30% energy compared to a traditional system with no
inverter. With a Panasonic Inverter compressor, the heat pump is always
producing heat with the maximum of efficiency and adapting the capacity
to the element.
The advantages of inverter heat pumps. Comparing Inverter and non-Inverter heat pumps.
HEAT IN THE
LIVING ROOM
(UNCOMFORTABLE)
COMFORT THE
LIVING ROOM
COLD IN THE
LIVING ROOM
(UNCOMFORTABLE)
NO INVERTER
Slow to start. Takes
longer to reach the
temperature set point.
INVERTER
Rapidly reaches
the desired
temperature.
NO INVERTER
The temperature
oscillates between the
two extremes and never
stabilises. The
temperature falls
and then rises quickly,
leading to a
consumption peak.
INVERTER
Adjusts the
temperature: more
comfort and greater
savings. Keeps the
temperature
comfortable all the
time.
33
Y 120%
B
E
S
A
E
R
INC
OF FREE
E
G
A
S
U
THE
IT Y*
ELECTRIC
Heat and produce Domestic Hot Water for free
Panasonic has developed an innovative algorithm for its HPM (Heat Pump Manager) which
drastically improves the Heat Pump’s use of self-generated electricity from connected
Photovoltaic panels. The Heat Pump will take the electricity generation by the solar system
into consideration for the heating system and the domestic hot water production, without
reducing confort in the house.
The HPM (Heat Pump Manager) activates the heat pump based on:
· Energy produced by the photovoltaic system.
· The consumption requirement of the house, eg if a washing machine is working, the heat
pump will not draw electricity from the photovoltaic system to avoid net increases on overall
energy consumption and hence maximise efficiency.
· Heating demand of the house (in case of high electricity production, the house can be
overheated by 1 or 2 degrees, or reduced by 1 or 2 degrees if low production of electricity).
As the production of domestic hot water is linked to the level of electricity generated by the
solar system, if this was too low, the heat pump would start a normal process to maintain
maximum comfort in the house for a given set time (defined by the user).
Key points
+
· Increases the amount of self-consumed electricity from the solar system up to 120%.
· Control the heat pump’s energy consumption according to the output of electricity from the
PV considering the electric energy consumtion requirement of the house.
· Innovative algorithm balancing the consumption of the heat pump and the comfort in the
house based on the outside temperature and the energy demand of the building.
· Easy configuration of the Heat Pump manager system with the PV system.
HPM
34
*Results of simulations for new housing (see next page)
AQUAREA
Comparison on New housing
Increase usage of self production by: 120%
Comparison on Old housing
Increase usage of self production by: 71%
The HPM could increase the energy consumption of the heat pump coming
from the Photovoltaic from 352 kWh to 775 kWh a year. Results of
simulations:
The HPM could increase the energy consumption of the heat pump coming
from the Photovoltaic from 526 kWh to 898 kWh a year. Results of
simulations:
New building Frankfurt (non-optimized)
Old building Frankfurt (non-optimized)
New building Frankfurt (optimized-eco)
PV Production (5,630 kWh/a)
73% (4,129 kWh/a)
27% (1,502 kWh/a)
(Energy)
To Grid
(4,129 kWh)
33% (1,149 kWh)
14% (352 kWh)
67% (2,351 kWh)
86% (2,116 kWh)
Consumption of the
House
(Energy)
To Grid
(3,706 kWh)
33% (1,149 kWh)
Consumption of the HP
Consumption of the
House
33% (1,149 kWh)
Consumption of the HP
Consumption of the
House
Usage of energy in the house
Conditions:
Installed PV Capacity: 5.64 kWp
Household Consumer Demand: 3,500 kWh/a
Hotwater Demand: 200 l/day @ 45 °C
Insulation Standard (Heat demand): 35 kWh/m2
Controller: Non-Intelligent
(Energy)
From Grid
(4,012 kWh)
Conditions:
Installed PV Capacity: 5.64 kWp
Household Consumer Demand: 3,500 kWh/a
Hotwater Demand: 200 l/day @ 40 °C
Insulation Standard (Heat demand): 35 kWh/m2
Controller: ECO
Conditions:
Installed PV Capacity: 5.64 kWp
Household Consumer Demand: 3,500 kWh/a
Hotwater Demand: 200 l/day @ 45 °C
Insulation Standard (Heat demand): 80 kWh/m2
Controller: Non-Intelligent
PV: Production of energy
From Grid
(5,627 kWh)
Conditions:
Installed PV Capacity: 5.64 kWp
Household Consumer Demand: 3,500 kWh/a
Hotwater Demand: 200 l/day @ 40 °C
Insulation Standard (Heat demand): 80 kWh/m2
Controller: ECO
PV: Production of energy
How to create added value of the
combination PV+HP?
· Optimize the HP considering the
PV production
· When the PV is producing enough
to cover the HP consumption,
then Tank mode will be forced to
heat up the DHW to 55 or 65
degrees
· If buffer tank on the installation,
temperature on the buffer tank
will increase 1-to 5 degrees or up
to 55°C.
Grid
HPM*
Home appliances and Lighting
78% (3,276 kWh)
Consumption of the HP
PV + HP control
Electrical meter*
Electrical panel
Consumption of the
House
Usage of energy in the house
Electrical meter*
Photovoltaic
solar panels
22% (898 kWh)
67% (2,351 kWh)
Consumption of the HP
Electrical panel
Inverter
33% (1,149 kWh)
88% (3,709 kWh)
Usage of energy in the house
From Grid
(6,060 kWh)
PV Production (5,630 kWh/a)
64% (3,583 kWh/a)
36% (2,047 kWh/a)
(Energy)
To Grid
(3,583 kWh)
12% (526 kWh)
67% (2,351 kWh)
62% (1,661 kWh)
Old building Frankfurt (optimized-eco)
PV Production (5,630 kWh/a)
70% (3,955 kWh/a)
30% (1,675 kWh/a)
(Energy)
To Grid
(3,955 kWh)
32% (775 kWh)
67% (2,351 kWh)
Usage of energy in the house
(Energy)
From Grid
(4,467 kWh)
PV Production (5,630 kWh/a)
66% (3,706 kWh/a)
34% (1,924 kWh/a)
Heating and DHW
*Device supply by Panasonic-PAW-HPM-Solar
(HPM + 2 Electrical Retors)
Standard combination PV+HP. Why the Panasonic HPM can increase by 120% the performance of the combination PV+HP
Typical Electricity consumption and production profile WITHOUT Panasonic HPM
Typical Electricity consumption and production profile optimize by the Panasonic HPM
Temperature in the house : 21 °C +/- 2 °C
Temperature in the house : 21 °C +/- 2 °C
-4,0 kW
-4,0 kW
-3,0 kW
-3,0 kW
-2,0 kW
-2,0 kW
-1,0 kW
-1,0 kW
0 kW
0 kW
1,0 kW
1,0 kW
2,0 kW
2,0 kW
3,0 kW
3,0 kW
4,0 kW
4,0 kW
5,0 kW
5,0 kW
6,0 kW
6,0 kW
0:00
12:00
Total electricity used in the house and by the HP
PV production used in the house and by the HP
PV production send to the grid
Electricity used by the HP
24:00
No optimization of the consumption of
the HP, production and consumption
only match on 13%
0:00
12:00
By forcing the HP to run when there is production.
The Panasonic HPM increases the consumption of
free electricity coming from the PV by 56%
The HP does not have to work when there is high demand of electricity
during the evening for example
24:00
The house temperature is
maintained, to ensure comfort.
A variation of 1 to 2 degrees can
be programmed in order to
increase the performance of the
system
35
HPM
TROL
NEW CON ON
FUNCTI
Control & connectivity
Aware of the importance of both control and connectivity in offering the best
comfort at the lowest price, Panasonic offers its customers cutting-edge
technology, specially designed to ensure our Aquarea heat pump systems deliver
maximum performance. You can properly manage the heat pump and perform
comprehensive monitoring and control, with all of the features the remote control
provides at home, from anywhere in the world thanks to the internet applications
Panasonic has created for you.
New
Connected to a router, all information of the heating system controlled by
the HPM is available from internet. Installers, service companies and end
user can monitor the installation remotely.
Panasonic has developed a new easy start up mode for the HPM.
Start your bivalent system in just 10 minutes!
36
AQUAREA
OPTIONAL
With or without built-in display
The next generation of Aquarea Manager
This new generation of smart controllers for eco-efficient heating features
our versatile stand-alone controller for heating and domestic hot water.
Panasonic offers:
Trends. Statistics. Consumption Energy Management-Optimization. Alarm.
Handling + Maintenance. Complete documentation etc.
READY STEADY GO
Easy Installation & Easy Configuration
Ready: Pre-programmed with up to 610
applications/system diagrams
Steady: At start up - state the number of
application/system diagram
Go: The controller starts working according
to selected diagram
External touch display with the Heat Pump Manager
Key points
· Easy selection with the “ready to go” system
· Up to 610 preconfiguration installations available on
www.panasonicproclub.com
· Cascade system possible for big installations.
· Bivalent control in order to also manage gas boilers
· Able to control 2 mixed heated zones
· Smart grid ready
· Solar panel mode in order to produce heat when the PV is generating
electricity
· Online access with control of all parameters.
· Easy installation and needs less than 3 minutes to configure a complex
system
Technical Specification
· New function: Smart Setup
· Control of 2 x Mixed Heating Circuits
· Floor screed dry program
· Cascade/bivalent controller
· Automatic switch from heating to cooling mode
· Night shift: - Internal Energy Manager
· Solar collector control
· Domestic hot water priority
· Easy to startup – easy to operate
· 7 output relays
· 0-10 V In/Output Signal
· 8 Sensor inputs (PT1000)
· USB interface (upload, service, remote control, trend)
· RS485 interface (com. with additional heat pump)
· RS485 interface (for external display)
· Built-in backlit text display
Easy mounting
Simple mounting without screws in the cabinet/door or on DIN-rail. Also
possible to mount directly on to the wall.
37
Control your heat pump from wherever you are. Control your comfort and efficiency with the
lowest energy consumption
M
NEW ROO RE
TU
TEMPERA R
SENSO
Take control from wherever you are!
COMPUTER SMARTPHONE
TABLET
HOME
OFFICE
STREET
WORK
GYM
Home or Office
Internet
Control
Ready
INTERNET
service in the cloud*
INTERFACE
WIFI
AIR
CONDITIONING
OP
TI
ON
AL
CONTROL YOUR
HEAT PUMP FROM
EVERYWHERE
WIRED ROOM
TEMPERATURE SENSOR
PAW-AW-WIFI-1TE FOR
INTESISHOMES
INTERNET CONTROL
PAW-AW-WIFI-1 IntesisHome for web control
PAW-AW-WIFI-1TE IntesisHome for web control with Wired room
temperature sensor to display the temperature of the room
ROUTER WIFI
* Functionalities depend on the license. The information indicated above is subject to changes and updates.
What’s Internet Control?
Internet Control is a next generation system providing user-friendly remote
control of air conditioning or heat pump units from anywhere, using a
simple Android or iOS smartphone, tablet or PC via internet with the
optional Wired Room temperature sensor, the temperature be display (only
with PAW-AW-WIFI-1A.
Simple Installation
Just connect the Internet Control device to the air conditioner or heat pump with the supplied wire and
then link it to your WIFI Access point.
Internet Control. Easy to install. Maximum benefit
Internet Control is underlined with the slogan “Your home in the cloud”,
meaning a simple and easy to handle solution has been considered for
every user to manage the device, not requiring any communication or
computer skills.
No servers. No adaptors. No wires. Just a small box needs to be connected
and placed close to the air conditioning indoor unit… and your smartphone,
tablet or PC.
Your existing WiFi connection does the rest when you are at home. Start
the App from your smartphone device, your tablet or your computer, and
enjoy a new experience in comfort. And if you are out of home, just launch
the App, and manage the air conditioning of your home from the cloud. An
intuitive and user-friendly application on the screen of your smartphone or
PC that lets you manage the air conditioning unit in the same way you do
with the remote controller at home.
Internet Control can be downloaded in Apple’s AppStore and Android’s
PlayStore.
Control your air conditioning with the smart internet control device
via smartphones, tablet, PC and smart desktop phone via internet
Offering the same functions as if you were at home or office: start/stop,
Mode Operation, Set Temperature, Room Temperature etc as well as the
new, advanced functionality provided by Internet Control to achieve the
best comfort and efficiency with the lowest energy consumption.
38
Case Study: Helen, Panasonic customer
“I was sick of heating my house in the mountains on the weekends when I
couldn’t go. It was a pointless and annoying expense.
But now, with Internet Control, I’ve managed to put the rigidity of weekly
programming behind me. If I go then I just put my Panasonic Aquarea
heating system on. And if I don’t go then I go to the cinema or the theatre
with the money I’ve saved.”
AQUAREA
Connectivity: Great flexibility for integration into your KNX / Zig Bee / Modbus projects allows
fully bi-directional monitoring and control of all the functioning parameters
Panasonic works with partners to ensure the
optimum solutions for our clients. Our partner
has designed a range of interfaces specifically
for Panasonic to provide complete monitoring,
control and full functionality of the entire
Aquarea line-up from KNX, Zig Bee and Modbus
installations.
This connectivity solution is made by a third
party company, please contact Panasonic for
more information.
Easy
control
by BMS
CONNECTIVITY
Interface to connect Aquarea to KNX
Reference: PAW-AW-KNX-1i
This new Aquarea-KNX interface allows full
monitoring and control, bi-directionally, of all
the functioning parameters of Aquarea control
from KNX installations.
· Small dimensions. / Quick installation and
possibility of hidden installation.
· External power not required.
· Direct connection to the unit.
· Fully KNX interoperable. Control and
monitoring, from sensors or gateways, of the
internal variables of the indoor unit and error
codes and indication.
· Aquarea unit can be controlled simultaneously
by the remote control of the Aquarea unit and
by KNX devices.
Interface to connect Aquarea to Zig Bee
Reference: PAW-ZIG-A2W
This new Aquarea-Zig Bee home automation
interface allows full monitoring and control,
bi-directionally, of all the functioning
parameters of the Aquarea control from Zig Bee
installations.
· Small dimensions. / Quick installation.
· External power not required.
· Direct connection to the Aquarea unit using
the same parameters as on the control.
· Fully Zig Bee interoperable. Control and
monitoring, from sensors or gateways, of the
internal variables of the indoor unit and error
codes and indication.
· Aquarea unit can be controlled simultaneously
by the remote control of the Aquarea unit and
by Zig Bee devices.
Interface to connect Aquarea to Modbus
Reference: PAW-AW-MBS-1
This new Aquarea-Modbus RTU Slave interface
allows monitoring and control, fully
bi-directionally, all the functioning parameters
of Aquarea control from Modbus installations.
· Small dimensions. / Quick installation and
possibility of hidden installation.
· External power not required.
· Direct connection to the unit.
· Fully Modbus interoperable. Control and
monitoring, from any BMS or PLC Modbus
Master, of internal variables of the indoor unit
and error codes and indication.
· Aquarea unit can be controlled simultaneously
by the remote control of the Aquarea unit and
by Modbus Master device.
4 x binary inputs
INTERFACE
INTERFACE
Any standard KNX device
Model name
PAW-AW-KNX-1i
PAW-ZIG-A2W
PAW-AW-MBS-1
PAW-AW-WIFI-1
PAW-AW-WIFI-1TE
Interface
KNX
Zig Bee
Modbus RTU
IntesisHome for web control
IntesisHome for web control with Wired room
temperature sensor to display the temperature
of a room
MODBUS
Building
Management
System
39
Aquarea Line-Up!
Three Phase
Heating only Heating only Heating only Heating only Heating and Heating and Heating and Heating and Heating and Heating and Heating only Heating and Heating and Heating only Heating and Heating and Heating and Heating and
cooling
cooling
cooling
cooling
cooling
cooling
cooling
cooling
cooling
cooling
cooling
cooling
Single
Phase
Bi-Bloc High performance
Three Phase
Single
Phase
Three Phase
Bi-Bloc T-CAP
Bi-Bloc
Single Phase
Aquarea High Performance for well insulated houses
Mono-Bloc
Single Phase
Three Phase
Bi-Bloc
Three Phase Single
Phase
Aquarea T-CAP for cold areas
Mono-Bloc
Three Phase Single
Phase
Bi-Bloc
Three Phase Single
Phase
Aquarea HT for retrofit
FIGURE 2 (F2)
Mono-Bloc
Three Phase Single
Phase
All in One
FIGURE 1 (F1)
FIGURE 3 (F3)
3kW
5kW
WH-ADC0309G3E5
WH-UD03EE5
A
(F1)
class pump
WH-ADC0309G3E5
WH-UD05EE5
A
(F1)
class pump
FIGURE 4 (F4)
6kW
FIGURE 5 (F5)
7kW
9kW
FIGURE 6 (F6)
12kW
14kW
16kW
WH-ADC0309G3E5
WH-ADC0309G3E5
WH-ADC1216G6E5
WH-ADC1216G6E5
WH-ADC1216G6E5
WH-UD07FE5
WH-UD09FE5
WH-UD12FE5 (F1)
WH-UD14FE5 (F1)
WH-UD16FE5 (F1)
A
A
A
A
A
(F1)
(F1)
class pump
class pump
class pump
class pump
class pump
WH-ADC0916G9E8
WH-ADC0916G9E8
WH-ADC0916G9E8
WH-ADC0916G9E8
WH-UD09FE8
WH-UD12FE8 (F1)
WH-UD14FE8 (F1)
WH-UD16FE8 (F1)
A
A
A
A
(F1)
class pump
class pump
class pump
class pump
WH-ADC1216G6E5
WH-ADC1216G6E5
WH-UX09FE5
WH-UX12FE5 (F1)
A
A
(F1)
class pump
class pump
WH-ADC0916G9E8
WH-ADC0916G9E8
WH-UX09FE8
WH-UX12FE8 (F1)
A
A
(F1)
class pump
class pump
WH-SDF03E3E5
WH-UD03EE5
(F2)
WH-SDC03E3E5
WH-UD03EE5
(F2)
A
class pump
A
class pump
WH-SDF05E3E5
WH-UD05EE5
(F2)
WH-SDC05E3E5
WH-UD05EE5
(F2)
A
class pump
A
class pump
WH-SDC07F3E5
WH-UD07FE5
(F4)
A
class pump
A
class pump
WH-SDC09F3E5
WH-UD09FE5
(F4)
WH-SDC09F3E8
WH-UD09FE8
(F5)
WH-MDF06E3E5
(F3)
WH-MDC05F3E5
(F3)
WH-ADC0916G9E8
WH-UX16FE8 (F1)
A
class pump
WH-MDC06E3E5
(F3)
A
class pump
A
class pump
WH-SDC12F6E5
WH-UD12FE5
(F5)
WH-SDC12F9E8
WH-UD12FE8
(F5)
A
class pump
A
class pump
WH-SDC14F6E5
WH-UD14FE5
(F5)
WH-SDC14F9E8
WH-UD14FE8
(F5)
A
class pump
A
class pump
class pump
WH-SDC16F9E8
WH-UD16FE8
(F5)
class pump
A
A
class pump
WH-MDF09E3E5
(F3)
WH-MDC09E3E5
(F3)
WH-MDC12C6E5 (F6)
WH-MDC14C6E5 (F6)
WH-MDC16C6E5 (F6)
A
WH-MDC09C3E8 (F6)
WH-MDC12C9E8 (F6)
WH-MDC14C9E8 (F6)
WH-MDC16C9E8 (F6)
WH-SXC09F3E5
WH-UX09FE5
(F5)
WH-SXC12F6E5
WH-UX12FE5
(F5)
A
class pump
WH-SXC09F3E8
WH-UX09FE8
(F5)
A
class pump
A
class pump
WH-SXC12F9E8
WH-UX12FE8
(F5)
A
class pump
A
class pump
WH-MXC09D3E5
(F6)
WH-MXC12D6E5
(F6)
WH-MXC09D3E8 (F6)
WH-MXC12D9E8 (F6)
WH-SHF09F3E5
WH-UH09FE5
(F5)
WH-SHF12F6E5
WH-UH12FE5
(F5)
WH-SHF09F3E8
WH-UH09FE8
(F5)
A
class pump
A
class pump
WH-SHF12F9E8
WH-UH12FE8
(F5)
A
class pump
A
class pump
WH-MHF09D3E5
(F6)
WH-MHF12D6E5
(F6)
WH-MHF09D3E8 (F6)
WH-MHF12D9E8 (F6)
Low connectivity : control of 3 way valve, tank heater On/Off signal, tank thermostat signal reception, On/Off from external control, weekly timer. High connectivity : Low connectivity + solar panels connection, room thermostat connection.
* Cooling mode activation possible by software. This activation can only be done by service partner.
40
WH-SDC16F6E5
WH-UD16CE5
(F5)
WH-SXC16F9E8
WH-UX16FE8
(F5)
A
class pump
NEW
AQUAREA
A
class pump
SEASONAL
EFFICIENCY
Aquarea All in One Bi-Bloc (Inverter)
High performance
3kW
5kW
7kW
T-CAP (High Capacity for cold areas)
9kW
12kW
9kW
12kW
14kW
16kW
16kW
Aquarea Bi-Bloc (Inverter)
High performance 3kW
9kW
12kW
T-CAP (High Capacity for cold areas)
5kW
7kW
9kW
12kW
AQUAREA HT
9kW
12kW
14kW
16kW
16kW
Aquarea Mono-Bloc (Inverter)
High performance
9kW
12kW
T-CAP (High Capacity for cold areas)
5kW
6kW
9kW
12kW
AQUAREA HT
9kW
12kW
14kW
16kW
* Not all products have A class pump.
Bi-Bloc
Mono-Bloc
Aquarea High Performance
Aquarea T-CAP
Aquarea HT
Aquarea High Performance
Aquarea T-CAP
Aquarea HT
5.00 COP
100%
Output water
65 ºC
5.08 COP
Output water
high efficiency
100%
AQUAREA T-CAP
HIGH TEMP
HEAT PUMP
AQUAREA
HIGH PERFORMANCE
AQUAREA T-CAP
HIGH TEMP
HEAT PUMP
capacity
at -15 ºC
high efficiency
AQUAREA
HIGH PERFORMANCE
capacity
at -15 ºC
65 ºC
Heating only
Heating and cooling
Heating only
Heating only
Heating and cooling
Heating only
Single Phase / Three Phase
Single Phase / Three Phase
Single Phase / Three Phase
Single Phase / Three Phase
41
NEW
*
Aquarea
All in One High
performance
Bi-Bloc Single Phase
Heating and Cooling
SEASONAL
EFFICIENCY
Panasonic has developed a highly efficient solution, easy to install.
Technical focus
· Space saving: 1827 x 600 x 720 (H x W x D)
· Reduce installation costs
· Piping on the bottom of the All in One (easy to install)
· Reduce timing and minimize installation errors
WH-UD03EE5
WH-UD05EE5
A
class pump
· Easy remote control to set up
· Electrical connections on the front
· Reduce installation spaces
· All piping connections at bottom of the indoor unit
· Easier installation and maintenance
· New remote control functions
* Cooling mode activation possible by software. This activation can only be done by service
partner.
Optional Controllers
WH-UD07FE5
WH-UD09FE5
WH-UD12FE5
WH-UD14FE5
WH-UD16FE5
WH-UD09FE8
WH-UD12FE8
WH-UD14FE8
WH-UD16FE8
Aquarea Manager with LCD.
PAW-HPM1
Aquarea Manager touch screen.
PAW-HPMED for HPM
Wireless LCD room thermostat
with weekly timer.
PAW-A2W-RTWIRELESS
Tank in the indoor unit
Hidrokit in the indoor unit
Single Phase (Power to indoor)
Three Phase (Power to indoor)
Kit
KIT-ADC3GE5 KIT-ADC5GE5 KIT-ADC7GE5 KIT-ADC9GE5 KIT-ADC12GE5 KIT-ADC14GE5 KIT-ADC16GE5 KIT-ADC9GE8 KIT-ADC12GE8 KIT-ADC14GE8
WH-ADC0309G3E5
WH-ADC1216G6E5
WH-ADC0916G9E8
Indoor unit
Outdoor unit
WH-UD03EE5 WH-UD05EE5 WH-UD07FE5 WH-UD09FE5 WH-UD12FE5 WH-UD14FE5 WH-UD16FE5 WH-UD09FE8 WH-UD12FE8 WH-UD14FE8
Heating capacity at +7°C
kW
3,20
5,00
7,00
9,00
12,00
14,00
16,00
9,00
12,00
14,00
COP at +7°C (heating water at 35°C)
5,00
4,63
4,46
4,13
4,75
4,57
4,28
4,85
4,75
4,57
Heating capacity at +2°C (heating water at 35°C) kW
3,20
4,20
6,55
6,70
11,40
12,40
13,00
9,00
11,40
12,40
COP at +2°C (heating water at 35°C)
3,56
3,11
3,34
3,13
3,45
3,36
3,29
3,59
3,45
3,36
Heating capacity at -7°C
kW
3,20
4,20
5,15
5,90
10,00
10,70
11,40
9,00
10,00
10,70
COP at -7°C
2,69
2,59
2,68
2,52
2,74
2,71
2,68
2,85
2,74
2,71
Cooling capacity at 35°C
kW
3,20
4,50
6,00
7,00
10,00
11,50
12,20
7,00
10,00
11,50
EER at 35°C (cooling water at 7/12°C)
3,08
2,69
2,63
2,43
2,81
2,64
2,57
3,17
2,81
2,64
Indoor unit
Dimensions
HxWxD
mm
1.827x600x720 1.827x600x720 1.827x600x720 1.827x600x720 1.827x600x720 1.827x600x720 1.827x600x720 1.827x600x720 1.827x600x720 1.827x600x720
Weight
kg
Water pipe connector
mm
R1 1/4
R1 1/4
R1 1/4
R1 1/4
R1 1/4
R1 1/4
R1 1/4
R1 1/4
R1 1/4
R1 1/4
A class Pump
No. of Speed
7
7
7
7
7
7
7
7
7
7
Input power (Min/Max.) W
Min: 21 W at 10l/min / Max: 135 W at 53.8l/min
Heating water flow (∆T=5 K. 35°C)
l/min 9,2
14,3
20,1
25,8
34,4
40,1
45,9
25,8
34,4
40,1
Capacity of integrated electric heater
kW
3
3
3
3
6
6
6
3
9
9
Input Power
Heating / Cooling
kW
0,64 / 1,04
1,08 / 1,67
1,59 / 2,30
2,20 / 2,90
2,57 / 3,60
3,11 / 4,40
3,78 / 4,80
1,90 / 2,25
2,57 / 3,55
3,11 / 4,40
Running current Heating / Cooling
A
3,00 / 4,8
5,00 / 7,6
7,30 / 10,40 10,10 / 13,10 11,70 / 16,10 14,10 / 19,70 17,10 / 21,50 2,90 / 3,40
3,90 / 5,30
4,70 / 6,60
Current 1 / Current 2
A
21,0 / 26,0
22,9 / 26,0
24,0 / 26,0
25,0 / 26,0
26,0 / 26,0
11,8 / 13,0
8,8 / 13,0
9,4 / 13,0
Recommended Fuse
A
30 / 15
30 / 15
30 / 30
30 / 30
30 / 30
30 / 30
30 / 30
16 / 16
16 / 16
16 / 16
Recommended power cable section
mm² 4,0 / 2,5
4,0 / 2,5
4,0 / 4,0
4,0 / 4,0
4,0 / 4,0
4,0 / 4,0
4,0 / 4,0
2,5 / 2,5
2,5 / 2,5
2,5 / 2,5
Water volume
L
200
200
200
200
200
200
200
200
200
200
Maximum water temperature
°C
65
65
65
65
65
65
65
65
65
65
Material inside tank
Stainless steel Stainless steel Stainless steel Stainless steel Stainless steel Stainless steel Stainless steel Stainless steel Stainless steel Stainless steel
Exchange surface
m²
2,1
2,1
2,1
2,1
2,1
2,1
2,1
2,1
2,1
2,1
Warranty of the stainless steel tank
10 years
10 years
10 years
10 years
10 years
10 years
10 years
10 years
10 years
10 years
Maintenance required on the tank
No
No
No
No
No
No
No
No
No
No
Outdoor unit
dB(A) / dB 47 / 65
48 / 66
48 / 66
49 / 67
50 / 67
51 / 68
53 / 70
49 / 65
50 / 66
51 / 71
Sound pressure level / Sound power level
mm / kg
622 x 824 x 298 / 39
795 x 900 x 320 / 66
1.340 x 900 x 320 / 106
Dimensions / Weight H x W x D
mm (Inch)
6,35 (1/4) / 12,7 (1/2)
6,35 (1/4) / 15,88 (5/8)
9,52 (3/8) / 15,88 (5/8)
Pipe diameter
Liquid / Gas
1,20 / 20
1,45 / 30
1,45 / 30
2,75 / 50
2,75 / 50
2,75 / 50
2,75 / 50
2,75 / 50
2,75 / 50
Refrigerant / Additional gas amount (R410A) kg / g/m 1,20 / 20
Pipe length range
m
3-15
3-15
3 – 30
3 – 30
3 – 30
3 – 30
3 – 30
3 – 30
3 – 30
3 – 30
7 / 10
7 / 10
7 / 10
7 / 10
7 / 10
7 / 10
7 / 10
7 / 10
7 / 10
7 / 10
Pipe length for nominal capacity / additional gas m
Elevation dif. (in/out)
m
5
5
20
20
20
20
20
20
20
20
Operation range
Outdoor ambient
°C
-20 to 35
-20 to 35
-20 to 35
-20 to 35
-20 to 35
-20 to 35
-20 to 35
-20 to 35
-20 to 35
-20 to 35
Water outlet at -2/-7/-15
°C
20 - 55 / 5 – 20 20 - 55 / 5 – 20 20 – 55 / 5 – 20 20 – 55 / 5 – 20 25 – 55 / 5 – 20 25 – 55 / 5 – 20 25 – 55 / 5 – 20 25 – 55 / 5 – 20 25 – 55 / 5 – 20 25 – 55 / 5 – 20
5.00 COP
high efficiency
IO
N
OP
T
Control
Ready
AL
Internet
INTERNET CONTROL
AQUAREA
HIGH PERFORMANCE
INTERNET CONTROL READY: Optional.
42
High
efficiency
heating
Environmentally
friendly
Down to
Boiler
Solar
Domestic
Easy
refrigerant
-20 ºC in
heating mode
connection
panels
connection
hot water
control
by BMS
R410A
OUTDOOR
TEMPERATURE
RETROFIT
SOLAR KIT
DHW
CONNECTIVITY
5 year
compressor
warranty
KIT-ADC16GE8
WH-UD16FE8
16,00
4,28
13,00
3,29
11,40
2,68
12,20
2,57
1.827x600x720
R1 1/4
7
45,9
9
3,78 / 4,80
5,70 / 7,20
9,9 / 13,0
16 / 16
2,5 / 2,5
200
65
Stainless steel
2,1
10 years
No
53 / 68
2,75 / 50
3 – 30
7 / 10
20
-20 to 35
25 – 55 / 5 – 20
COP classification is at 230 V only in accordance with EU
directive 2003/32/EC. Sound pressure measured at 1 m from
the outdoor unit and at 1.5 m height. Performance in
agreement with EN14511. 1) Insulated tested under
EN12897.
* Preliminary design. Significant changes may occur.
NEW
AQUAREA
*
Aquarea
All in One T-CAP
Bi-Bloc Single Phase /
Three Phase
Heating And Cooling
SEASONAL
EFFICIENCY
All the benefits of the T-CAP All in ONE unit!
Panasonic has developed a highly efficient solution, easy to install.
A
class pump
· Easy remote control to set up
· Electrical connections on the front
· Reduce installation spaces
· All piping connections at bottom of the indoor unit
· Easier installation and maintenance
· 1 phase and 3 phase
· New remote control functions
Technical focus
· Space saving: 1827 x 600 x 720 (H x W x D)
· Reduce installation costs
· Piping on the bottom of the All in One (easy to install)
· Reduce timing and minimize installation errors
Optional Controllers
WH-UX09FE5
WH-UX12FE5
WH-UX16FE8
WH-UX09FE8
WH-UX12FE8
Aquarea Manager with LCD.
PAW-HPM1
Tank in the indoor unit
Hidrokit in the indoor unit
Kit
Indoor unit
Outdoor unit
Heating capacity at +7°C
COP at +7°C (heating water at 35°C)
Heating capacity at +2°C (heating water at 35°C)
COP at +2°C (heating water at 35°C)
Heating capacity at -7°C
COP at -7°C
Cooling capacity at 35°C
EER at 35°C (cooling water at 7/12°C)
Indoor unit
Dimensions
HxWxD
Weight
Water pipe connector
A class Pump
No. of Speed
Input power (Min/Max.)
Heating water flow (∆T=5 K. 35°C)
Capacity of integrated electric heater
Input Power
Heating / Cooling
Running current
Heating / Cooling
Current 1 / Current 2
Recommended Fuse
Recommended power cable section
Water volume
Maximum water temperature
Material inside tank
Exchange surface
Warranty of the Stainless steel tank
Maintenance required on the tank
Outdoor unit
Sound pressure level / Sound power level
Dimensions / Weight H x W x D
Pipe diameter
Liquid / Gas
Refrigerant / Additional gas amount (R410A)
Pipe length range
Pipe length for nominal capacity / additional gas
Elevation dif. (in/out)
Operation range
Outdoor ambient
Water outlet at -2/-7/-15
4.85 COP
high efficiency
IO
N
OP
T
Control
Ready
AL
Internet
INTERNET CONTROL
AQUAREA
HIGH PERFORMANCE
INTERNET CONTROL READY: Optional.
High
efficiency
heating
kW
kW
kW
kW
mm
kg
W
l/min
kW
kW
A
A
A
mm²
L
°C
m²
dB(A) / dB
mm / kg
mm (Inch)
kg / g/m
m
m
m
°C
°C
Wireless LCD room thermostat
with weekly timer.
PAW-A2W-RTWIRELESS
Aquarea Manager touch screen.
PAW-HPMED for HPM
Single Phase (Power to indoor)
KIT-AXC9FE5
WH-ADC1216G6E5
WH-UX09FE5
9,00
4,85
9,00
3,59
9,00
2,85
7,00
3,17
KIT-AXC12FE5
WH-ADC1216G6E5
WH-UX12FE5
12,00
4,75
12,00
3,44
12,00
2,72
10,00
2,81
Three Phase (Power to indoor)
KIT-AXC9FE8
WH-ADC0916G9E8
WH-UX09FE8
9,00
4,85
9,00
3,59
9,00
2,85
7,00
3,17
KIT-AXC12FE8
WH-ADC0916G9E8
WH-UX12FE8
12,00
4,75
12,00
3,44
12,00
2,72
10,00
2,81
KIT-AXC16FE8
WH-ADC0916G9E8
WH-UX16FE8
16,00
4,28
16,00
3,10
16,00
2,49
12,20
2,57
1.827 x 600 x 720
1.827 x 600 x 720
1.827 x 600 x 720
1.827 x 600 x 720
1.827 x 600 x 720
R1¼
7
R1¼
7
25,8
6
1,90
8,8 (10,4)
25,0 / 26,0
30 / 30
4,0 / 4,0
200
65
Stainless steel
2,1
10 years
No
34,4
6
2,57
11,9 (16,7)
29,0 / 26,0
30 / 30
4,0 / 4,0
200
65
Stainless steel
2,1
10 years
No
49 / 66
1.340 x 900 x 320 / 107
9,52 (3/8) / 15,88 (5/8)
3,10 / 50
3 – 30
7 / 10
20
-20 to 35
25 – 55 / 5 – 20
50 / 67
1.340 x 900 x 320 / 107
9,52 (3/8) / 15,88 (5/8)
3,10 / 50
3 – 30
7 / 10
20
-20 to 35
25 – 55 / 5 – 20
Environmentally
friendly
Down to
Boiler
R1¼
R1¼
7
7
Min: 21 W at 10l/min / Max: 135 W at 53.8l/min
25,8
34,4
9
9
1,90
2,57
2,9 (3,4)
3,9 (5,4)
14,7 / 13,0
11,9 / 13,0
16 / 16
16 / 16 / 16
2,5 / 2,5
2,5 / 2,5
200
200
65
65
Stainless steel
Stainless steel
2,1
2,1
10 years
10 years
No
No
Solar
49 / 66
1.340 x 900 x 320 / 110
9,52 (3/8) / 15,88 (5/8)
3,10 / 50
3 – 30
7 / 10
20
-20 to 35
25 – 55 / 5 – 20
Domestic
Easy
refrigerant
-20 ºC in
heating mode
connection
panels
connection
hot water
control
by BMS
R410A
OUTDOOR
TEMPERATURE
RETROFIT
SOLAR KIT
DHW
CONNECTIVITY
R1¼
7
45,9
9
2,57
7,2
15,5 / 13,0
16 / 16
2,5 / 2,5
200
65
Stainless steel
2,1
10 years
No
50 / 67
1.340 x 900 x 320 / 110
9,52 (3/8) / 15,88 (5/8)
3,10 / 50
3 – 30
7 / 10
20
-20 to 35
25 – 55 / 5 – 20
5 year
compressor
warranty
50 / 67
1.340 x 900 x 320 / 110
9,52 (3/8) / 15,88 (5/8)
2,90 / 50
3 – 30
7 / 10
20
-20 to 35
25 – 55 / 5 – 20
COP classification is at 230 V only in accordance with EU
directive 2003/32/EC. Sound pressure measured at 1 m from
the outdoor unit and at 1.5 m height. Performance in
agreement with EN14511. 1) Insulated tested under
EN12897.
* Preliminary design. Significant changes may occur.
43
AQUAREA
HIGH PERFORMANCE
BI-BLOC SINGLE PHASE
HEATING ONLY - SDF
HEATING AND COOLING - SDC
3 AND 5KW
A
DESIGNED FOR LOW
CONSUMPTION
HOMES
The 3 and 5kW is specially designed for low energy homes and
achieves an impressive COP of 5 (on the 3.2kW).
Thanks to the system’s high degree of technology and advanced control, it
is able to maintain a high capacity and efficiency even at -7°C and -15°C.
The Aquarea’s software is optimised to the requirements of low
consumption homes in order to maximise energy efficiency. Whatever the
weather, Aquarea can work even at -20°C. The compact design of the
outdoor unit makes installation very easy.
class pump
· Efficient control of room temperature based on the outdoor
temperature, indoor temperature using the Aquarea Manager.
· Super efficient: COP of 5 in the 3.2kW!
· A Class Pump
· Special software for low consumption homes with minimum output
temperature: 20°C
· Works down to -20°C
· Automatic Air purge valve
· Display of the compressor frequency
Technical focus
Optional Controllers
WH-UD03EE5
WH-UD05EE5
Aquarea Manager with LCD.
PAW-HPM1
Kit
Indoor unit
Outdoor unit
Heating capacity at +7°C
COP at +7°C (heating water at 35°C)
Heating capacity at +2°C (heating water at 35°C)
COP at +2°C (heating water at 35°C)
Heating capacity at -7°C
COP at -7°C
Cooling capacity at 35°C
EER at 35°C (cooling water at 7/12°C)
Indoor unit
Dimensions
HxWxD
Weight
Water pipe connector
A class Pump
No. of Speed
Input power (Min/Max.)
Heating water flow (ΔT=5 K. 35°C)
Capacity of integrated electric heater
Input Power
H/C
Running and Starting current H / C
Current 1 / Current 2
Recommended Fuse
Recommended power cable section
Outdoor unit
Sound pressure level
Sound power level
Dimensions
HxWxD
Weight
Pipe diameter
Liquid
Gas
Refrigerant (R410A)
Pipe length range
Pipe length for nominal capacity
Pipe length for additional gas
Additional gas amount (R410A)
Elevation difference (in/out)
Operation range
Outdoor ambient
Water outlet at -2/-7/-15
Single Phase Heating Only
KIT-WF03C3E5
WH-SDF03E3E5
WH-UD03EE5
3,20
5,00
3,20
3,56
3,20
2,69
-
KIT-WF05C3E5
WH-SDF05E3E5
WH-UD05EE5
5,00
4,63
4,20
3,11
4,20
2,59
-
892 x 502 x 353
43
28
Variable Speed
892 x 502 x 353
43
28
Variable Speed
W
l/min
kW
kW
A
A
A
mm²
9,2
3
0,64 / 1,04
3 / 4,8
11,0 / 26,0
15 / 30
2,5 / 4,0
14,3
3
1,08 / 1,67
5 / 7,6
12,0 / 26,0
15 / 30
2,5 / 4,0
dB(A)
dB
mm
kg
mm (Inch)
mm (Inch)
kg
m
m
m
g/m
m
°C
°C
47
65
622 x 824 x 298
39
6,35 (1/4)
12,7 (1/2)
1,20
3-15
7
10
20
5
-20 to 35
20 - 55
48
66
622 x 824 x 298
39
6,35 (1/4)
12,7 (1/2)
1,20
3-15
7
10
20
5
-20 to 35
20 - 55
kW
kW
kW
kW
mm
kg
mm
Single Phase Heating and Cooling
KIT-WC03C3E5
WH-SDC03E3E5
WH-UD03EE5
3,20
5,00
3,20
3,56
3,20
2,69
3,20
3,08
892 x 502 x 353
44
28
Variable Speed
Min: 21 W at 10l/min / Max: 135 W at 53.8l/min
9,2
3
0,64 / 1,04
3 / 4,8
11,0 / 26,0
15 / 30
2,5 / 4,0
47
65
622 x 824 x 298
39
6,35 (1/4)
12,7 (1/2)
1,20
3-15
7
10
20
5
-20 to 35
20 - 55
COP classification is at 230 V only in accordance with EU directive 2003/32/EC. Sound pressure measured at 1 m from the outdoor unit and at 1.5 m height. Performance in agreement with EN14511.
5.00 COP
high efficiency
IO
OP
T
Control
Ready
N
AL
Internet
INTERNET CONTROL
AQUAREA
HIGH PERFORMANCE
INTERNET CONTROL READY: Optional.
44
High
efficiency
heating
Easy
Boiler
Solar
connection
heating mode
panels
connection
hot water
refrigerant
-20 ºC in
control
by BMS
R410A
OUTDOOR
TEMPERATURE
RETROFIT
SOLAR KIT
DHW
CONNECTIVITY
Environmentally
friendly
Down to
Wireless LCD room thermostat
with weekly timer.
PAW-A2W-RTWIRELESS
Aquarea Manager touch screen.
PAW-HPMED for HPM
Domestic
5 year
compressor
warranty
KIT-WC05C3E5
WH-SDC05E3E5
WH-UD05EE5
5,00
4,63
4,20
3,11
4,20
2,59
4,50
2,69
892 x 502 x 353
44
28
Variable Speed
14,3
3
1,08 / 1,67
5 / 7,6
12,0 / 26,0
15 / 30
2,5 / 4,0
48
66
622 x 824 x 298
39
6,35 (1/4)
12,7 (1/2)
1,20
3-15
7
10
20
5
-20 to 35
20 - 55
AQUAREA
Aquarea
High Performance
Bi-Bloc Single Phase /
Three Phase
Heating And Cooling - SDC
A
SEASONAL
EFFICIENCY
The Aquarea SDC range adapts well in an existing install with a
boiler backup, and in a new application with underfloor heating,
low temperature radiators or even fan-coil heaters.
This range can also be connected to a solar kit in order to increase
efficiency and minimize the impact on the ecosystem. Finally, it is
possible to connect a thermostat for better heating and cooling control
and management.
class pump
Technical focus
· NEW! New remote control functions
· Efficient control of room temperature based on the outdoor
temperature, indoor temperature using the Aquarea Manager.
· Optional Smartphone control
· Range from 7 to 16kW, Single and Three Phase
· Maximum hydraulic module output temperature: 55°C
· Works down to -20°C
· Maximum 30 m rise between the outdoor unit and the hydraulic module
· Cooling temperature range 5–20°C
Optional Controllers
WH-UD07FE5
WH-UD09FE5
WH-UD12FE5
WH-UD14FE5
WH-UD16FE5
WH-UD09FE8
WH-UD12FE8
WH-UD14FE8
WH-UD16FE8
Kit
Indoor unit
Outdoor unit
Heating capacity at +7°C
COP at +7°C (heating water at 35°C)
Heating capacity at +2°C
COP at +2°C (heating water at 35°C)
Heating capacity at -7°C
COP at -7°C (heating water at 35°C)
Cooling capacity at 35°C (cooling water at 7°C)
EER at 35°C (cooling water at 7°C)
Indoor unit
Dimensions
HxWxD
Weight
Water pipe connector
Pump
No. of Speed
Input power (Min/Max.)
Heating water flow (∆T=5 K. 35°C)
Capacity of integrated electric heater
Input Power
Heating / Cooling
Running and Starting current Heating / Cooling
Current 1 / Current 2
Recommended Fuse
Recommended power cable section
Outdoor unit
Sound pressure level
Sound power level
Dimensions / Weight
HxWxD
Pipe diameter
Liquid / Gas
Refrigerant (R410A)
Pipe length range
Pipe length for nominal capacity
Pipe length for additional gas
Additional gas amount (R410A)
Elevation difference (in/out)
Operation range
Outdoor ambient
Water outlet at -2/-7/-15
Heating / Cooling
Aquarea Manager with LCD.
PAW-HPM1
Single Phase (Power to indoor)
KIT-WC07F3E5¹ KIT-WC09F3E5¹
WH-SDC07F3E5 WH-SDC09F3E5
WH-UD07FE5 WH-UD09FE5
7,00
9,00
4,46
4,13
6,55
6,70
3,34
3,13
5,15
5,90
2,68
5,52
6,00
7,00
2,61
2,41
KIT-WC12F6E5²
WH-SDC12F6E5
WH-UD12FE5
12,0
4,74
11,40
3,44
10,00
2,73
10,00
2,81
KIT-WC14F6E5²
WH-SDC14F6E5
WH-UD14FE5
14,00
4,56
12,40
3,36
10,70
2,70
11,50
2,64
892 x 502 x 353
43
R1 1/4
7
892 x 502 x 353
43
R1 1/4
7
892 x 502 x 353
45
R1 1/4
7
20,1
3
1,59 / 2,30
7,30 / 10,40
21,0 / 26,0
30 / 30
4,0 / 4,0
25,8
3
2,20 / 2,90
10,10 / 13,10
22,9 / 26,0
30 / 30
4,0 / 4,0
34,4
6
2,53 / 3,56
11,50 / 16,00
24,0 / 26,0
30 / 30
4,0 / 4,0
892 x 502 x 353 892 x 502 x 353 892 x 502 x 353
46
46
46
R1 1/4
R1 1/4
R1 1/4
7
7
7
Min: 21 W at 10l/min / Max: 135 W at 53.8l/min
40,1
45,9
25,8
6
6
3
3,07 / 4,36
3,74 / 4,76
1,86 / 2,21
13,90 / 19,50
16,90 / 21,30
2,90 / 3,40
25,0 / 26,0
26,0 / 26,0
11,8 / 13,0
30 / 30
30 / 30
16 / 16
4,0 / 4,0
4,0 / 4,0
2,5 / 2,5
50
67
51
68
kW
kW
kW
kW
mm
kg
W
l/min
kW
kW
A
A
A
mm²
dB(A)
dB
mm / kg
mm (Inch)
kg
m
m
m
g/m
m
°C
°C
48
66
49
67
795 x 900 x 320 / 66
6,35 (1/4) / 15,88 (5/8)
1,45
1,45
3 – 30
3 – 30
7
7
10
10
30
30
20
20
-20 to 35
-20 to 35
25 – 55 / 5 – 20 25 – 55 / 5 – 20
Wireless LCD room thermostat
with weekly timer.
PAW-A2W-RTWIRELESS
Aquarea Manager touch screen.
PAW-HPMED for HPM
KIT-WC16F6E5²
WH-SDC16F6E5
WH-UD16FE5
16,00
4,28
13,00
3,28
11,40
2,68
12,20
2,56
Three Phase (Power to indoor)
KIT-WC09F3E8³ KIT-WC12F9E8³
WH-SDC09F3E8 WH-SDC12F9E8
WH-UD09FE8 WH-UD12FE8
9,00
12,00
4,84
4,14
9,00
11,40
3,59
3,44
9,00
10,00
2,85
2,23
7,00
10,00
3,17
2,81
53
70
KIT-WC14F9E8³
WH-SDC14F9E8
WH-UD14FE8
14,00
4,56
12,40
3,36
10,70
2,70
11,50
2,64
KIT-WC16F9E8³
WH-SDC16F9E8
WH-UD16FE8
16,00
4,28
16,00
3,28
11,40
2,68
12,20
2,56
892 x 502 x 353
46
R1 1/4
7
892 x 502 x 353
47
R1 1/4
7
892 x 502 x 353
47
R1 1/4
7
34,4
9
2,53 / 3,56
3,90 / 5,30
8,8 / 13,0
16 / 16
2,5 / 2,5
40,1
9
3,07 / 4,36
4,70 / 6,60
9,4 / 13,0
16 / 16
2,5 / 2,5
45,9
9
3,74 / 4,76
5,70 / 7,20
9,9 / 13,0 / 16 / 16
2,5 / 2,5
51
68
53
70
2,55
3 – 30
7
10
50
20
-20 to 35
25 – 55 / 5 – 20
2,55
3 – 30
7
10
50
20
-20 to 35
25 – 55 / 5 – 20
49
50
66
67
1.340 x 900 x 320 / 101
9,52 (3/8) / 15,88 (5/8)
2,55
2,55
2,55
2,55
2,55
3 – 30
3 – 30
3 – 30
3 – 30
3 – 30
7
7
7
7
7
10
10
10
10
10
50
50
50
50
50
20
20
20
20
20
-20 to 35
-20 to 35
-20 to 35
-20 to 35
-20 to 35
25 – 55 / 5 – 20 25 – 55 / 5 – 20 25 – 55 / 5 – 20 25 – 55 / 5 – 20 25 – 55 / 5 – 20
COP classification is at 230 V only in accordance with EU directive 2003/32/EC. Sound pressure measured at 1 m from the outdoor unit and at 1.5 m height. Performance in agreement with EN14511.
1) Available from September 2014. 2) Available from May 2014. 3) Available from June 2014.
4.84 COP
high efficiency
IO
N
OP
T
Control
Ready
AL
Internet
INTERNET CONTROL
AQUAREA
HIGH PERFORMANCE
High
efficiency
heating
Environmentally
friendly
Down to
Boiler
Solar
Domestic
Easy
refrigerant
-20 ºC in
heating mode
connection
panels
connection
hot water
control
by BMS
R410A
OUTDOOR
TEMPERATURE
RETROFIT
SOLAR KIT
DHW
CONNECTIVITY
5 year
compressor
warranty
INTERNET CONTROL READY: Optional.
45
NEW
AQUAREA T-CAP
BI-BLOC SINGLE PHASE /
THREE PHASE
HEATING AND COOLING - SXC
SEASONAL
EFFICIENCY
The new SXC is ideal for residential properties which don’t have
an external boiler and require a maintained capacity level.
T-CAP stands for Total Capacity. This new line-up is able to maintain the
same nominal capacity even at -15°C without the help of an electrical
booster heater. T-CAP is also able to provide extremely high efficiency,
whatever the outside temperature or the water temperature. The SXC
adapts well in an existing install with a boiler backup, and in a new
application with underfloor heating, low temperature radiators or even
fan-coil heaters. This Range can also be connected to a solar kit in order
to increase efficiency and minimize the impact on the ecosystem. Finally,
it is possible to connect a thermostat for even better heating or cooling
control and management.
A
class pump
Technical focus
· NEW! 16kW Model: Maintains 16kW capacity at outdoor temperatures
down to -15°C
· NEW! New remote control functions
· Efficient control of room temperature based on the outdoor
temperature, indoor temperature using the Aquarea Manager.
· Optional Smartphone control
· Range from 9 to 16kW, Single and Three Phase
· Maximum hydraulic module output temperature: 55°C
· Works down to -20°C (Cooling temperature range 5–20°C)
· Constant capacity at outdoor temperatures down to -15°C
· Maximum 20 m rise between the outdoor unit and the hydraulic module
Optional Controllers
WH-UX09FE5
WH-UX12FE5
WH-UX09FE8
WH-UX12FE8
WH-UX16FE8
Aquarea Manager with LCD.
PAW-HPM1
Kit
Indoor unit
Outdoor unit
Heating capacity at +7°C (heating water at 35°C)
COP at +7°C (heating water at 35°C)
Heating capacity at +2°C (heating water at 35°C)
COP at +2°C (heating water at 35°C)
Heating capacity at -7°C (heating water at 35°C)
COP at -7°C (heating water at 35°C)
Cooling capacity at 35°C (cooling water at 7°C)
EER at 35°C (cooling water at 7°C)
Indoor unit
Dimensions
HxWxD
Weight
Water pipe connector
Pump
No. of Speed
Input power (Min/Max.)
Heating water flow (ΔT=5 K. 35°C)
Capacity of integrated electric heater
Input Power
Starting Current
Current 1 / Current 2
Recommended Fuse
Recommended power cable section
Outdoor unit
Sound pressure level
Sound power level
Dimensions / Weight
HxWxD
Pipe diameter
Liquid / Gas
Refrigerant (R410A)
Pipe length range
Pipe length for nominal capacity
Pipe length for additional gas
Additional gas amount (R410A)
Elevation difference (in/out)
Operation range
Outdoor ambient
Water outlet at -2/-7/-15
Heating / Cooling
kW
kW
kW
kW
mm
kg
Aquarea Manager touch screen.
PAW-HPMED for HPM
Single Phase (Power to indoor)
KIT-WXC09F3E5
KIT-WXC12F6E5
WH-SXC09F3E5
WH-SXC12F6E5
WH-UX09FE5
WH-UX12FE5
9,00
12,00
4,84
4,74
9,00
12,00
3,59
3,44
9,00
12,00
2,85
2,72
7,00
10,00
3,17
2,81
892 x 502 x 353
44
R1¼
7
892 x 502 x 353
45
R1¼
7
W
l/min
kW
kW
A
A
A
mm²
25,8
3
1,86
10,2
25,0 / 26,0
30 / 30
4,0 / 4,0
34,4
6
2,53
16,5
29,0 / 26,0
30 / 30
4,0 / 4,0
dB(A)
dB
mm / kg
mm (Inch)
kg
m
m
m
g/m
m
°C
°C
49
66
1.340 x 900 x 320 / 107
9,52 (3/8) / 15,88 (5/8)
2,85
3 – 30
7
10
50
20
-20 to 35
25 – 55 / 5 – 20
50
67
1.340 x 900 x 320 / 107
9,52 (3/8) / 15,88 (5/8)
2,85
3 – 30
7
10
50
20
-20 to 35
25 – 55 / 5 – 20
Three Phase (Power to indoor)
KIT-WXC09F3E8
KIT-WXC12F9E8
WH-SXC09F3E8
WH-SXC12F9E8
WH-UX09FE8
WH-UX12FE8
9,00
12,00
4,84
4,74
9,00
12,00
3,59
3,44
9,00
12,00
2,85
2,72
7,00
10,00
3,17
2,81
892 x 502 x 353
892 x 502 x 353
45
46
R1¼
R1¼
7
7
Min: 21 W at 10l/min / Max: 135 W at 53.8l/min
25,8
34,4
3
9
1,86
2,53
3,4
5,4
14,7 / 13,0
11,9 / 13,0
16 / 16
16 / 16
2,5 / 2,5
2,5 / 2,5
49
66
1.340 x 900 x 320 / 109
9,52 (3/8) / 15,88 (5/8)
2,85
3 – 30
7
10
50
20
-20 to 35
25 – 55 / 5 – 20
50
67
1.340 x 900 x 320 / 109
9,52 (3/8) / 15,88 (5/8)
2,85
3 – 30
7
10
50
20
-20 to 35
25 – 55 / 5 – 20
COP classification is at 230 V only in accordance with EU directive 2003/32/EC. Sound pressure measured at 1 m from the outdoor unit and at 1.5 m height. Performance in agreement with EN14511.
100%
IO
OP
T
Control
Ready
N
AL
Internet
INTERNET CONTROL
capacity
at -15 ºC
AQUAREA T-CAP
INTERNET CONTROL READY: Optional.
46
High
efficiency
heating
Easy
Boiler
Solar
connection
heating mode
panels
connection
hot water
refrigerant
-20 ºC in
control
by BMS
R410A
OUTDOOR
TEMPERATURE
RETROFIT
SOLAR KIT
DHW
CONNECTIVITY
Environmentally
friendly
Down to
Domestic
5 year
compressor
warranty
Wireless LCD room thermostat
with weekly timer.
PAW-A2W-RTWIRELESS
KIT-WXC16F9E8
WH-SXC16F9E8
WH-UX16FE8
16,00
4,28
16,00
3,10
16,00
2,49
12,20
2,57
892 x 502 x 353
52
R1¼
7
45,9
9
3,74
7,2
15,5 / 13,0
16 / 16
2,5 / 2,5
53
70
1.340 x 900 x 320 / 110
9,52 (3/8) / 15,88 (5/8)
2,90
3 – 30
7
10
50
20
-20 to 35
25 – 55 / 5 – 20
AQUAREA
AQUAREA HT
BI-BLOC SINGLE PHASE /
THREE PHASE
HEATING ONLY - SHF
SEASONAL
EFFICIENCY
Aquarea HT is able to deliver water heated to 65°C with the Heat
Pump alone.
For a house with high temperature radiators (for example, cast iron
radiators), the Aquarea High Temperature Solution is most suited as it
provides output water temperatures of 65°C even at -20°C.
A
class pump
Technical focus
· NEW! New remote control functions
· Efficient control of room temperature based on the outdoor
temperature, indoor temperature using the Aquarea Manager.
· Optional Smartphone control
· Range from 9 to 12kW, Single and Three Phase
· Maximum hydraulic module output temperature: 65°C
· Works down to -20°C
· Maximum 20 m rise between the outdoor unit and the hydraulic module
Optional Controllers
WH-UH09FE5
WH-UH12FE5
WH-UH09FE8
WH-UH12FE8
Aquarea Manager with LCD.
PAW-HPM1
Kit
Indoor unit
Outdoor unit
Heating capacity at +7°C (heating water at 35°C)
COP at +7°C (heating water at 35°C)
Heating capacity at +2°C (heating water at 35°C)
COP at +2°C (heating water at 35°C)
Heating capacity at -7°C (heating water at 35°C)
COP at -7°C (heating water at 35°C)
Heating capacity at +7°C (heating water at 65°C)
COP at +7°C (heating water at 65°C)
Heating capacity at +2°C (heating water at 65°C)
COP at +2°C (heating water at 65°C)
Heating capacity at -7°C (heating water at 65°C)
COP at -7°C (heating water at 65°C)
Indoor unit
Dimensions / Weight
HxWxD
Water pipe connector
Pump
No. of Speed
Input Power (Max.)
Heating water flow (ΔT=5 K. 35°C)
Capacity of integrated electric heater
Input Power
Running and Starting current
Current 1 / Current 2
Recommended Fuse
Recommended power cable section
Outdoor unit
Sound pressure level / Sound power level
Dimensions / Weight
HxWxD
Pipe diameter
Liquid / Gas
Refrigerant (R407C)
Pipe length range
Pipe length for nominal capacity
Pipe length for additional gas
Additional gas amount (R407C)
Elevation difference (in/out)
Operation range
Outdoor ambient
Water outlet at -2/-7/-15
Internet
Output water
IO
N
AL
65 ºC
OP
T
Control
Ready
INTERNET CONTROL
HIGH TEMP
HEAT PUMP
High
efficiency
heating
kW
kW
kW
kW
kW
kW
mm / kg
Single Phase (Power to indoor)
KIT-WHF09F3E5¹
WH-SHF09F3E5
WH-UH09FE5
9,00
4,64
9,00
3,45
9,00
2,74
9,00
2,25
9,00
1,88
8,90
1,64
892 x 502 x 353 / 46
R1¼
7
Three Phase (Power to indoor)
KIT-WHF09F3E8²
WH-SHF09F3E8
WH-UH09FE8
9,00
4,64
9,00
3,45
9,00
2,74
9,00
2,25
9,00
1,88
8,90
1,64
KIT-WHF12F6E5¹
WH-SHF12F6E5
WH-UH12FE5
12,00
4,46
12,00
3,26
12,00
2,52
12,00
2,20
10,30
1,83
9,60
1,61
W
l/min
kW
kW
A
A
A
mm²
25,8
3
1,94
9,3
28,5 / 26,0
30 / 30
4,0 / 4,0
892 x 502 x 353 / 47
892 x 502 x 353 / 47
R1¼
R1¼
7
7
Min: 21 W at 10l/min / Max: 135 W at 53.8l/min
34,4
25,8
6
3
2,69
1,94
12,9
3,0
29,0 / 26,0
14,7 / 13,0
30 / 30 / 30 / 16
4,0 / 4,0 / 4,0 / 2,5
dB(A) / dB
mm / kg
mm (Inch)
kg
m
m
m
g/m
m
°C
°C
49 / 66
1.340 x 900 x 320 / 104
9,52 (3/8) / 15,88 (5/8)
2,90
3 – 30
7
10
70
20
-20 to 35
25 – 65
50 / 67
1.340 x 900 x 320 / 104
9,52 (3/8) / 15,88 (5/8)
2,90
3 – 30
7
10
70
20
-20 to 35
25 – 65
49 / 66
1.340 x 900 x 320 / 110
9,52 (3/8) / 15,88 (5/8)
2,90
3 – 30
7
10
70
20
-20 to 35
25 – 65
Easy
Boiler
Solar
connection
heating mode
panels
connection
hot water
refrigerant
-20 ºC in
control
by BMS
R407C
OUTDOOR
TEMPERATURE
RETROFIT
SOLAR KIT
DHW
CONNECTIVITY
Environmentally
friendly
Down to
Wireless LCD room thermostat
with weekly timer.
PAW-A2W-RTWIRELESS
Aquarea Manager touch screen.
PAW-HPMED for HPM
Domestic
5 year
compressor
warranty
KIT-WHF12F9E8²
WH-SHF12F9E8
WH-UH12FE8
12,00
4,46
12,00
3,26
12,00
2,52
12,00
2,20
10,30
1,83
9,60
1,61
892 x 502 x 353 / 48
R1¼
7
34,4
9
2,69
4,2
10,9 / 13,0
30 / 16 / 4,0 / 2,5 / 50 / 67
1.340 x 900 x 320 / 110
9,52 (3/8) / 15,88 (5/8)
2,90
3 – 30
7
10
70
20
-20 to 35
25 – 65
COP classification is at 230 V only in accordance with EU
directive 2003/32/EC. Sound pressure measured at 1 m
from the outdoor unit and at 1.5 m height. Performance in
agreement with EN14511.
1) Available from March 2014. 2) Available from February
2014.
INTERNET CONTROL READY: Optional.
47
NEW
AQUAREA
HIGH PERFORMANCE
MONO-BLOC SINGLE PHASE
HEATING ONLY - MDF
HEATING AND COOLING - MDC
DESIGN FOR LOW
CONSUMPTION HOMES
Panasonic has designed the new Aquarea Mono-Bloc heat pump
for houses which have high performance requirements but limited
space to install the outdoor unit.
Whatever the weather, Aquarea can work even at -20°C. The Mono-Bloc
is easy to install in new and existing residential properties.
A
class pump
Technical focus
· NEW! 5kW Model
· NEW! New remote control functions
· Efficient control of room temperature based on the outdoor
temperature, indoor temperature using the Aquarea Manager.
· Optional Smartphone control
· Range from 6 to 9kW, Single Phase
· Maximum hydraulic module output temperature: 55°C
· Works down to -20°C
· Plug and play system
Optional Controllers
NEW REMOTE CONTROL
Only for the 5 kW Monobloc
Aquarea Manager with LCD.
PAW-HPM1
Heating capacity at +7°C (heating water at 35°C)
COP at +7°C (heating water at 35°C)
Heating capacity at +2°C (heating water at 35°C)
COP at +2°C (heating water at 35°C)
Heating capacity at -7°C (heating water at 35°C)
COP at -7°C (heating water at 35°C)
Cooling capacity at 35°C (cooling water at 7°C)¹
EER at 35°C (cooling water at 7°C)¹
Sound pressure level
Sound power level
Dimensions
HxWxD
Weight
Water pipe connector
Pump
No. of Speed
Input power (Min/Max.)
Water Flow (ΔT=5 K. 35°C)
Capacity of integrated electric heater
Input Power at +7°C
Running and Starting current at +7°C
Recommended Fuse
Recommended power cable section
Operation range
Outdoor ambient
Water outlet at -2/-7/-15
kW
kW
kW
kW
dB(A)
dB
mm
kg
W
l/min
kW
kW
A
A
mm²
°C
°C
Single Phase Heating Only
WH-MDF06E3E5
6,00
4,48
5,00
3,45
5,15
2,68
–
–
47
65
865 x 1283 x 320
112
R1¼
Variable Speed
WH-MDF09E3E5
9,00
4,15
7,45
3,14
7,70
2,12
–
–
49
67
865 x 1283 x 320
112
R1¼
Variable Speed
17,2
3,00
1,34
6,1
30 / 16
4,0 / 2,5
-20 to 35
20 – 55
25,8
3,00
2,17
9,9
30 / 16
4,0 / 2,5
-20 to 35
20 – 55
Aquarea Manager touch screen.
PAW-HPMED for HPM
Single Phase Heating and Cooling
WH-MDC05F3E5
WH-MDC06E3E5
5,00
6,00
5,08
4,48
4,80
5,00
3,75
3,45
4,50
5,15
2,98
2,68
4,50
5,50
3,33
2,74
47
47
65
65
865 x 1.283 x 320
865 x 1.283 x 320
107
112
R1¼
R1¼
7
Variable Speed
Min: 21 W at 10l/min / Max: 135 W at 53.8l/min
9,2
17,2
3
3,00
0,985
1,34
3
6,1
30 / 15
30 / 16
4,0 / 2,5
4,0 / 2,5
-20 to 35
-20 to 35
20 – 55
20 – 55
COP classification is at 230 V only in accordance with EU directive 2003/32/EC.
Sound pressure measured at 1 m from the outdoor unit and at 1.5 m height.
Performance in agreement with EN14511.
1. Tentative. Authorized service partner or Authorized installer can enable the cooling mode through a special operation via the remote controller on site.
2. Tentative.
5.07 COP
high efficiency
IO
OP
T
Control
Ready
N
AL
Internet
INTERNET CONTROL
AQUAREA
HIGH PERFORMANCE
INTERNET CONTROL READY: Optional.
48
Easy
High
Environmentally
efficiency
heating
refrigerant
heating mode
control
by BMS
R410A
OUTDOOR
TEMPERATURE
CONNECTIVITY
friendly
Down to
-20 ºC in
5 year
compressor
warranty
Wireless LCD room thermostat
with weekly timer.
PAW-A2W-RTWIRELESS
WH-MDC09E3E5
9,00
4,15
7,45
3,14
7,70
2,12
7,00
2,44
49
67
865 x 1.283 x 320
112
R1¼
Variable Speed
25,8
3,00
2,17
9,9
30 / 16
4,0 / 2,5
-20 to 35
20 – 55
AQUAREA
AQUAREA
HIGH PERFORMANCE
MONO-BLOC SINGLE PHASE /
THREE PHASE
HEATING AND COOLING - MDC
The Aquarea MDC range adapts well in an existing installation
with a boiler backup, and in a new application with underfloor
heating, low temperature radiators or even fan-coil heaters.
This range can also be connected to a solar kit in order to increase
efficiency and minimize the impact on the ecosystem. Finally, it is
possible to connect a thermostat for even better heating and cooling
control and management.
Technical focus
· Efficient control of room temperature based on the outdoor
temperature, indoor temperature using the Aquarea Manager.
· Optional Smartphone control
· Range from 9 to 16kW, Single and Three Phase
· Maximum hydraulic module output temperature: 55°C
· Works down to -20°C
· Cooling temperature range 5–20°C
Optional Controllers
Aquarea Manager with LCD.
PAW-HPM1
Heating capacity at +7°C (heating water at 35°C)
COP at +7°C (heating water at 35°C)
Heating capacity at +2°C (heating water at 35°C)
COP at +2°C (heating water at 35°C)
Heating capacity at -7°C (heating water at 35°C)
COP at -7°C (heating water at 35°C)
Cooling capacity at 35°C (cooling water at 7°C)¹
EER at 35°C (cooling water at 7°C)¹
Sound pressure level
Sound power level
Dimensions
HxWxD
Weight
Water pipe connector
Pump
No. of Speed
Input power (Max.)
Heating water flow (ΔT=5 K. 35°C)
Capacity of integrated electric heater
Input Power
Heating
Cooling¹
Running and Starting current Heating
Cooling¹
Current 1
Current 2
Current 3
Recommended Fuse
Recommended power cable section
Operation range
Outdoor ambient
Water outlet at -2/-7/-15
Heating / Cooling¹
kW
kW
kW
kW
dB(A)
dB
mm
kg
W
l/min
kW
kW
kW
A
A
A
A
A
A
mm²
°C
°C
Single Phase
WH-MDC12C6E5
12,00
4,67
11,40
3,41
10,00
2,70
10,00
2,78
50
67
1.410 x 1.283 x 320
153
R1¼
3
190
34,4
6
2,57
3,60
11,6
16,1
24,0
26,0
13,0
30 / 30 / 16
4,0 / 4,0 / 2,5
-20 to 35
25 – 55 / 5 – 20
Wireless LCD room thermostat
with weekly timer.
PAW-A2W-RTWIRELESS
Aquarea Manager touch screen.
PAW-HPMED for HPM
WH-MDC14C6E5
14,00
4,50
12,40
3,32
10,70
2,68
11,50
2,61
51
68
1.410 x 1.283 x 320
153
R1¼
3
190
40,1
6
3,11
4,40
14,1
19,7
25,0
26,0
13,0
30 / 30 / 16
4,0 / 4,0 / 2,5
-20 to 35
25 – 55 / 5 – 20
WH-MDC16C6E5
16,00
4,23
13,00
3,25
11,40
2,65
12,20
2,54
53
70
1.410 x 1.283 x 320
153
R1¼
3
190
45,9
6
3,78
4,80
17,1
21,5
26,0
26,0
13,0
30 / 30 / 16
4,0 / 4,0 / 2,5
-20 to 35
25 – 55 / 5 – 20
Three Phase
WH-MDC09C3E8
9,00
4,74
9,00
3,53
9,00
2,81
7,00
3,11
49
66
1.410 x 1.283 x 320
157
R1¼
3
190
25,8
3
1,90
2,25
2,9
3,4
11,8
13,0
16 / 16
2,5 / 2,5
-20 to 35
25 – 55 / 5 – 20
WH-MDC12C9E8
12,00
4,67
11,40
3,41
10,00
2,70
10,00
2,78
50
67
1.410 x 1.283 x 320
157
R1¼
3
190
34,4
9
2,57
3,60
3,9
5,3
8,8
13,0
13,0
16 / 16 / 16
2,5 / 2,5 / 2,5
-20 to 35
25 – 55 / 5 – 20
WH-MDC14C9E8
14,00
4,50
12,40
3,32
10,70
2,68
11,50
2,61
51
68
1.410 x 1.283 x 320
157
R1¼
3
190
40,1
9
3,11
4,40
4,7
6,6
9,4
13,0
13,0
16 / 16 / 16
2,5 / 2,5 / 2,5
-20 to 35
25 – 55 / 5 – 20
WH-MDC16C9E8
16,00
4,23
13,00
3,25
11,40
2,65
12,20
2,54
53
70
1.410 x 1.283 x 320
157
R1¼
3
190
45,9
9
3,78
4,80
5,7
7,2
9,9
13,0
13,0
16 / 16 / 16
2,5 / 2,5 / 2,5
-20 to 35
25 – 55 / 5 – 20
COP classification is at 230 V only in accordance with EU directive 2003/32/EC. Sound pressure measured at 1 m from the outdoor unit and at 1.5 m height. Performance in agreement with EN14511.
1. Specifications for Heating an Cooling models.
4.74 COP
high efficiency
IO
OP
T
Control
Ready
N
AL
Internet
INTERNET CONTROL
AQUAREA
HIGH PERFORMANCE
High
efficiency
heating
Easy
Boiler
Solar
connection
heating mode
panels
connection
hot water
refrigerant
-20 ºC in
control
by BMS
R410A
OUTDOOR
TEMPERATURE
RETROFIT
SOLAR KIT
DHW
CONNECTIVITY
Environmentally
friendly
Down to
Domestic
5 year
compressor
warranty
INTERNET CONTROL READY: Optional.
49
AQUAREA T-CAP
MONO-BLOC SINGLE PHASE /
THREE PHASE
HEATING AND COOLING - MXC
The MXC is ideal for residential properties which don’t have an
external boiler and require a maintained capacity level.
T-CAP stands for Total Capacity. This new line-up is able to maintain the
same nominal capacity even at -15°C without the help of an electrical
booster heater. T-CAP is also able to provide extremely high efficiency,
whatever the outside temperature or the water temperature. The MXC
adapts well in an existing install with a boiler backup, and in a new
application with underfloor heating, low temperature radiators or even
fan-coil heaters. This range can also be connected to a solar kit in order
to increase efficiency and minimize the impact on the ecosystem. Finally,
it is possible to connect a thermostat for even better heating or cooling
control and management.
Technical focus
· Efficient control of room temperature based on the outdoor
temperature, indoor temperature using the Aquarea Manager.
· Optional Smartphone control
· Range from 9 to 12kW, Single and Three Phase
· Maximum hydraulic module output temperature: 55°C
· Works down to -20°C
· Cooling temperature range 5–20°C
Optional Controllers
Aquarea Manager with LCD.
PAW-HPM1
Heating capacity at +7°C (heating water at 35°C)
COP at +7°C (heating water at 35°C)
Heating capacity at +2°C (heating water at 35°C)
COP at +2°C (heating water at 35°C)
Heating capacity at -7°C (heating water at 35°C)
COP at -7°C (heating water at 35°C)
Cooling capacity at 35°C (cooling water at 7°C)
EER at 35°C (cooling water at 7°C)
Sound pressure level
Sound power level
Dimensions
HxWxD
Weight
Water pipe connector
Pump
No. of Speed
Input power (Max.)
Heating water flow (ΔT=5 K. 35°C)
Capacity of integrated electric heater
Input Power
Starting Current
Current 1
Current 2
Current 3
Recommended Fuse
Recommended power cable section
Operation range
Outdoor ambient
Water outlet at -2/-7/-15
Heating / Cooling¹
kW
kW
kW
kW
dB(A)
dB
mm
kg
W
l/min
kW
kW
A
A
A
A
A
mm²
°C
°C
Single Phase
WH-MXC09D3E5
9,00
4,74
9,00
3,53
9,00
2,81
7,00
3,11
49
66
14.10 x 1.283 x 320
155
R1¼
3
190
25,8
3
1,90
10,4
25,0
26,0
Aquarea Manager touch screen.
PAW-HPMED for HPM
Three Phase
WH-MXC09D3E8
9,00
4,74
9,00
3,53
9,00
2,81
7,00
3,11
49
66
1.410 x 1.283 x 320
158
R1¼
3
190
25,8
3
1,90
2,9
14,7
13,0
WH-MXC12D6E5
12,00
4,67
12,00
3,40
12,00
2,70
10,00
2,78
50
67
1.410 x 1.283 x 320
155
R1¼
3
190
34,4
6
2,57
16,7
29,0
26,0
13,0
30 / 30 / 16
4,0 / 4,0 / 2,5
-20 to 35
25 – 55 / 5 – 20
30 / 30
4,0 / 4,0
-20 to 35
25 – 55 / 5 – 20
16 / 16
2,5 / 2,5
-20 to 35
25 – 55 / 5 – 20
COP classification is at 230 V only in accordance with EU directive 2003/32/EC. Sound pressure measured at 1 m from the outdoor unit and at 1.5 m height. Performance in agreement with EN14511.
100%
IO
OP
T
Control
Ready
N
AL
Internet
INTERNET CONTROL
capacity
at -15 ºC
AQUAREA T-CAP
INTERNET CONTROL READY: Optional.
50
High
efficiency
heating
Easy
Boiler
Solar
connection
heating mode
panels
connection
hot water
refrigerant
-20 ºC in
control
by BMS
R410A
OUTDOOR
TEMPERATURE
RETROFIT
SOLAR KIT
DHW
CONNECTIVITY
Environmentally
friendly
Down to
Domestic
5 year
compressor
warranty
Wireless LCD room thermostat
with weekly timer.
PAW-A2W-RTWIRELESS
WH-MXC12D9E8
12,00
4,67
12,00
3,40
12,00
2,70
10,00
2,78
50
67
1.410 x 1.283 x 320
158
R1¼
3
190
34,4
9
2,57
3,9
11,9
13,0
13,0
16 / 16 / 16
2,5 / 2,5 / 2,5
-20 to 35
25 – 55 / 5 – 20
AQUAREA
AQUAREA HT
MONO-BLOC SINGLE PHASE /
THREE PHASE
HEATING ONLY - MHF
Aquarea HT is able to deliver 65°C with the Heat Pump alone.
For a house with high temperature radiators (for example, cast iron
radiators), the Aquarea High Temperature Solution is most suited as it
provides output water temperatures of 65°C even at -20°C.
Technical focus
· Efficient control of room temperature based on the outdoor
temperature, indoor temperature using the Aquarea Manager.
· Optional Smartphone control
· Range from 9 to 12kW, Single and Three Phase
· Maximum hydraulic module output temperature: 65°C
· Works down to -20°C
Optional Controllers
Aquarea Manager with LCD.
PAW-HPM1
Heating capacity at +7°C (heating water at 35°C)
COP at +7°C (heating water at 35°C)
Heating capacity at +2°C (heating water at 35°C)
COP at +2°C (heating water at 35°C)
Heating capacity at -7°C (heating water at 35°C)
COP at -7°C (heating water at 35°C)
Heating capacity at +7°C (heating water at 65°C)
COP at +7°C (heating water at 65°C)
Heating capacity at +2°C (heating water at 65°C)
COP at +2°C (heating water at 65°C)
Heating capacity at -7°C (heating water at 65°C)
COP at -7°C (heating water at 65°C)
Sound pressure level
Sound power level
Dimensions
HxWxD
Weight
Water pipe connector
Pump
No. of Speed
Input Power (Max.)
Heating water flow (ΔT=5 K. 35°C)
Capacity of integrated electric heater
Input Power
Running and Starting current
Current 1
Current 2
Current 3
Recommended Fuse
Recommended power cable section
Operation range
Outdoor ambient
Water outlet at -2/-7/-15
kW
kW
kW
kW
kW
kW
dB(A)
dB
mm
kg
W
l/min
kW
kW
A
A
A
A
A
mm²
°C
°C
Single Phase
WH-MHF09D3E5
9,00
4,55
9,00
3,40
9,00
2,70
9,00
2,25
9,00
1,88
8,90
1,62
49
66
1.410 x 1.283 x 320
155
R1¼
3
190
25,8
3
1,98
9,5
28,5
26,0
Aquarea Manager touch screen.
PAW-HPMED for HPM
Three Phase
WH-MHF09D3E8
9,00
4,55
9,00
3,40
9,00
2,70
9,00
2,25
9,00
1,88
8,90
1,62
49
66
1.410 x 1.283 x 320
158
R1¼
3
190
25,8
3
1,98
9,5
14,7
13,0
WH-MHF12D6E5
12,00
4,40
12,00
3,23
12,00
2,50
12,00
2,20
10,30
1,83
9,60
1,61
50
67
1.410 x 1.283 x 320
155
R1¼
3
190
34,4
6
2,73
12,8
29,0
26,0
13,0
30 / 30 / 16
4,0 / 4,0 / 2,5
-20 to 35
25 – 65
30 / 30
4,0 / 4,0
-20 to 35
25 – 65
-16 / 16
2,5 / 2,5
-20 to 35
25 – 65
Wireless LCD room thermostat
with weekly timer.
PAW-A2W-RTWIRELESS
WH-MHF12D9E8
12,00
4,40
12,00
3,23
12,00
2,50
12,00
2,20
10,30
1,83
9,60
1,61
50
67
1.410 x 1.283 x 320
158
R1¼
3
190
34,4
9
2,73
12,8
11,9
13,0
13,0
16 / 16 / 16
2,5 / 2,5 / 2,5
-20 to 35
25 – 65
COP classification is at 230 V only in accordance with EU directive 2003/32/EC. Sound pressure measured at 1 m from the outdoor unit and at 1.5 m height. Performance in agreement with EN14511.
Internet
Output water
IO
N
AL
65 ºC
OP
T
Control
Ready
INTERNET CONTROL
HIGH TEMP
HEAT PUMP
High
efficiency
heating
Easy
Boiler
Solar
connection
heating mode
panels
connection
hot water
refrigerant
-20 ºC in
control
by BMS
R407C
OUTDOOR
TEMPERATURE
RETROFIT
SOLAR KIT
DHW
CONNECTIVITY
Environmentally
friendly
Down to
Domestic
5 year
compressor
warranty
INTERNET CONTROL READY: Optional.
51
AQUAREA AIR RADIATORS
WITH AQUAREA AIR
The slimline Panasonic Aquarea Air radiators deliver high
efficiency climate control. With a depth of just under 13 cm they
are at the cutting edge of the market. Blending easily into the
home, Aquarea Air’s elegant design and product refinements are
clear to see in every detail.
2.0kW
The Aquarea Air’s slimline profile has been achieved thanks to the
innovative layout of the ventilation unit and the heat exchanger.
The fan is tangential with asymmetric blades and the large
surface heat exchanger enables high airflows to be achieved with
low pressure loss and low noise levels. Exceptional ventilation
efficiency means the motor uses considerably less energy (low
wattage). The fan speed is continuously modulated by the
temperature controller with proportional integral logic, with
undoubted advantages for regulating the temperature and
humidity in summer mode.
WATER AT
35
°C
NEEDED
WITH STANDARD CAST
RADIATORS
All temperature curves and capacity are available on
www.panasonicproclub.com
2.0kW
WATER AT
65
°C
NEEDED
Fan Coils for Heat Pump application
Without radiant heating
Total heating capacity
W
Water flow
kg/h
Water pressure drop
kPa
Air flow
m³/h
Speed
Maximum input power
W
Sound pressure level
dB(A)
Inlet water temperature
°C
Outlet water temperature °C
Inlet air temperature
°C
Outlet air temperature
°C
Dimensions (H x W x D)
mm
Weight
kg
3 ways valve included
Touch screen thermostat
PAW-AAIR-200
PAW-AAIR-200L
138
160
23,7
27,5
0,1
0,2
28
37
Main Fan Off Super Min
2
5
17,6
18,8
35
35
30
30
19
19
34,5
32,6
735 x 576 x 129
17
Yes
Yes
217
37,3
0,4
55
Min
7
24,7
35
30
19
38,9
470
80,8
2,0
113
Med
9
33,2
35
30
19
32,0
570
98,0
2,9
162
Max
13
39,4
35
30
19
30,0
PAW-AAIR-700
PAW-AAIR-700L
223
360
38,4
61,9
0,1
0,1
44
84
Main Fan Off Super Min
3
9
18,4
19,6
35
35
30
30
19
19
34,9
32,4
935 x 579 x 129
20
Yes
Yes
708
121,8
0,3
155
Min
14
25,8
35
30
19
33,3
1.032
177,5
0,8
252
Med
18
34,1
35
30
19
31,8
PAW-AAIR-900
PAW-AAIR-900L
273
475
47,0
81,7
0,1
0,2
54
110
Main Fan Off Super Min
3
11
18,4
22,3
35
35
30
30
19
19
34,8
32,5
1.135 x 579 x 129
23
Yes
Yes
1.188
204,3
1,0
320
Max
22
40,2
35
30
19
30,6
Front panel with
a radiant effect
During winter, the operating principle is based on micro fans of very low power consumption
and minimum noise that send hot air, coming from the heat exchanger, to the inside of the
front panel of the device and therefore heat it effectively. With this principle, the terminal also
provides significant power while heating, without running the main fan. Comfort temperatures
are therefore maintained, without air movements and in silence. In summer mode, the airflow
generated by the micro fans is stopped to avoid any dew formation on the terminal’s front
surface.
Radiant effect for
better comfort
Very silent and efficient DC
fan motor
Filter
52
Drain for cooling mode
operation
886
152,4
0,5
248
Min
16
26,2
35
30
19
30,2
1.420
244,2
1,6
367
Med
20
34,4
35
30
19
31,1
DC fan motor for high
efficiency
1.703
292,9
2,2
461
Max
24
42,2
35
30
19
30,6
NEW
AQUAREA
32%
MORE EFFICIENT
THAN STANDARD
RADIATORS
PAW-AAIR-900
PAW-AAIR-700
PAW-AAIR-200
Main features
· Front panel heating with radiant effect
· High heating capacity (without main fan running)
· 4 fan speeds and capacities
· Exclusive design
· Extremely compact (only 12.9 cm deep)
· Cooling and dehumidification functions possible (drain is needed)
· 3-way valve included (no overflow valve needed on the installation if more than 3
radiators installed)
· Touch screen thermostat
New line up of Super low temperature radiators for Heat Pump application:
Aquarea Air 200/700/900 with radiating effect
Major Benefit
· On the water installation
- Only 1 water temperature on the water circuit (35°C)
- No expansive 2 zone kits
- No overflow valve (as Aquarea Air has a 3-way valve)
- Very easy to install
· On the efficiency
- COP with water at 35°C is 32% higher than efficiency with water at 45°C!
(case MDF06, at +7°C)
Accessories for Aquarea Air
PAW-AAIR-LEGS-1
Kits of 2 legs to support the Aquarea Air on the floor and to protect the water pipings
Operating on heating mode with radiator
using only radiant effect
A
129
579
659
Operating on heating mode with radiant
effect and fan mode
200
735
A
700
935
900
1.135
Operating on cooling mode with fan
A
A
B
B
A
B
Threaded supports
Supports cover
53
Accessories
Tanks
Stainless Steel Tank
Enamelled Tank
Enamelled high efficiency Tank
Model
WH-TD20E3E5
WH-TD30E3E5-1 PAW-TE20E3STD PAW-TE30E3STD PAW-TE20E3HI
PAW-TE30E3HI
PAW-TE50E3HI
Enamelled 2 coils
Tank (for bivalent
Solar + HP)
PAW-TE30C2E3ESTD
Water volume
L
200
300
190
290
200
288
440
287
Maximum water temperature
Dimensions Hight / Diameter
Weight
Electric heater
Power supply
Material inside tank
Exchange surface
°C
mm
kg
kW
V
75
1.150 / 580
49
3
230
Stainless steel
1,4
75
1.600 / 580
65
3
230
Stainless steel
1,8
95
1.432 / 540
65
3
230
Enamelled
1,90
95
1.794 / 600
85
3
230
Enamelled
2,55
95
1.804 / 600
78
3
230
Enamelled
2,25
95
1.294 / 700
139
3
230
Enamelled
3,20
95
1.921 / 700
222
3
230
Enamelled
6,20
95
1.294 / 700
145
3
230
1,9
Yes
Yes
★★★★
★★★★
★★★★
10 years
No
2,3
Yes
Yes
★★★★
★★★★
★★★★
10 years
No
1,6
Yes
Yes
★★★★
★★★★
★★★★
7 years
Yearly
1,8
Yes
Yes
★★★★
★★★★
★★★★
7 years
Yearly
1,2
Yes
Yes
★★★★
★★★★
★★★★
7 years
Yearly
1,8
Yes
Yes
★★★★
★★★★
★★★★
7 years
Yearly
2,4
Yes
Yes
★★★★
★★★★
★★★★
7 years
Yearly
m²
Energy loss at 65°C¹
kWh/24h
3 Way valve included
20 m temperature sensor cable included
Heat up time
Valuation
Energy losses
Valuation
Efficiency of the tank
Valuation
Warranty
Maintenance required
2,4 (for HP) +1,1 (for
solar or boiler)
2,7
Yes
Yes
★★★★
★★★★
★★★★
7 years
Yearly
High efficiency water
tanks with a large
exchange surface and high
levels of insulation to
minimise energy losses.
1) Insulated tested under EN12897.
Aquarea Tank. Tanks and buffer tank in one!
Tanks and buffer tank in one!
Model
Water volume
L
Maximum water temperature
°C
Dimension
HxWxD
mm
Weight
kg
Electric heater
kW
Power supply
V
Material inside tank
Exchange surface
m²
Energy loss at 65°C¹
kWh/24h
A class pump
Number of speed
Pressure drop (Min / Max)
kPa
Input power (Min / Max)
W
3 Way valve included
Safety thermostat with contact for failure part of E-Heating
Location of the electrical heater
Electrical backup heater on the buffer tank
CZ-NS1P // CZ-NS3P // CZ-NS2P
CZ-TK1
Solar Kit Accessories
CZ-NS1P PCB for solar connection kit for split
systems
CZ-NS2P PCB for solar connection kit for
monoblock systems
CZ-NS3P PCB for solar connection kit for
monoblock systems 6 & 9 kW
54
PAW-TS1 / PAW-TS2
Sanitary Tank Accessories
CZ-TK1
Temperature sensor kit for third
party tank (with copper pocket and 6
m length sensor cable)
PAW-TS1
Tank sensor with 6 meter cable
length
PAW-TS2
Tank sensor with 6 meter cable
length
Standard Sanitary
PAW-TD20B8E3-NDS
185 (for DHW tank) / 80 (for buffer tank)
100
1.810 x 600 x 632
150
3
230 - 2p
Stainless steel
2,3
1,3
Stepless (800-4250 rpm)
5/6
3 / 45
Yes
Yes
Mid
Optional
CZ-NE1P
Deice Accessories
CZ-NE1P
Base pan heater (for all old
Bi-Block and Mono Block, not for
the 3 and 5 kW)
CZ-NE2P
Base pan heater (for 3 kW and 5
kW)
CZ-NE3P
Base pan heater (for all new F
generation products: F3, F6, F9)
Connectivity Solutions
Model name
Interface
PAW-AW-KNX-1i KNX Interface
PAW-ZIG-A2W
Interface to connect to Zig Bee
PAW-AW-MBS-1 Modbus Interface
PAW-AW-WIFI-1A IntesisHome for web control
PAW-AW-WIFI-1TE Wired room temperature sensor
(only for PAW-AW-WIFI-1A)
NEW
PAW-HPM1
Aquarea Manager Kits
PAW-HPM12ZONE-U
PAW-HPM12ZONE-M
PAW-HPM12ZONELCD-U
PAW-HPM12ZONELCD-M
PAW-HPM12ZONE-F
PAW-HPM12ZONELCD-F
AQUAREA
PAW-HPM2
HPM with roomsensor and setpoint adaption for Bi-bloc + sensors
HPM with roomsensor and setpoint adaption for Mono-bloc + sensors
HPM with LCD Wireless Room Thermostat for Bi-bloc + sensors
HPM with LCD Wireless Room Thermostat for Mono-bloc + sensors
HPM with roomsensor and setpoint adaption for Mono-bloc + Bi-bloc F type + sensor
HPM with LCD Wireless Room Thermostat for Mono-bloc + Bi-bloc F type + sensor
PAW-HPMED
Aquarea Manager Accessories
PAW-HPM1
PAW-HPM2
PAW-HPMINT-U
PAW-HPMINT-M
PAW-HP-MINT-F
PAW-HPMB1
PAW-HPMDHW
PAW-HPMSOL1
PAW-HPMAH1
PAW-HPMR4
PAW-HPMED
PAW-HPMLCD
PAW-LANCABLE
PAW-A2WSWITCH
PAW-HPM-CASE
PAW-DEWPOINTSENSOR
PAW-HPMUH
Aquarea Manager with LCD
Aquarea Manager without LCD
Interface to connect Aquarea Manager to Heat pump Aquarea Bi-Bloc, with inverter control C and D types
Interface to connect Aquarea Manager to Heat pump Aquarea Mono-Bloc, with inverter control
Interface to connect Aquarea Manager to Heat pump Aquarea Bi-Bloc F type
Buffer tank sensor
Buffer tank sensor with well
Buffer tank sensor solar (with higher temperature range)
Water flow pipe sensor for heating circuit
Room sensor + set point adaption
Touch screen
Room thermostast with LCD
Network cable
Network switch
HPM casing with Premounted cables NEW!
Dew point sensor
Outdoor temperature sensor
Hydraulic Accessories
PAW-2PMP2ZONE
PAW-FILTER
PAW-FILTER-ONLY
2 zone kit, hydraulic switch, manifold, 2 A-class pumps, 1 mixture valve and check valve + filter
2 check valves + filter with 1"
Filter with 1"
PAW-A2W-RTWIRED
PAW-A2W-RTWIRELESS
Room Thermostats
PAW-A2W-RTWIRED
PAW-A2W-RTWIRELESS
Wired LCD room thermostat with weekly timer
Wireless LCD room thermostat with weekly timer
Accessories For All In One 2014
PAW-FP-WMP-1
Flexible pipings and wall mounting plate for all in one (Available from October 2014)
55
Examples of installations with Aquarea Manager
Temperature control in the 2 zones with
PAW-HPM12ZONE-U
2 heat pumps in cascade with the PAWHPM12ZONELCD-U
2 heat pump + boiler with PAWHPM12ZONE-U
56
AQUAREA
Temperature control in zones 2 + ECS with
PAW-HPM12ZONE-U
Management of heat pump + boiler and
DHW with PAW-HPM12ZONELCD-U
3 heat pumps in cascade with PAWHPM12ZONELCD-U
57
A typical example of savings and efficiencies
that Aquarea can offer to you
A 125m2 house in Reims
The example below shows a typical 3 bedroom French home and highlights
the potential savings that can be achieved with Panasonic's Aquarea heat
pump.*
Building data
Address
Building area
Standard heating requirement
Internal gains
Solar gains (windows)
Indoor design temperature
Outdoor temp. limit for heating 'on'
Heat distribution
Max. flow water temperature
Max. return water temperature
Solar collector area
Reims (French)
125 m2
11,3 kW
5625 kWh/year
4500 kWh/year
20 °C
15 °C
Underfloor heating by 100 %
Radiator heating by -- %
Wall heating by -- %
55 °C
50 °C
-- m2
Rate data
Service hot water
Type of service
Hot water with heat pump
Description
Tank volume
300 Litre
Shut off times total
0.0 h/day
Average daily need
200 Litre
Weekends with shut off times
yes
Cold water inlet temperature
10 °C
Daytime rate of heat pump
Time for daytime rate
Target tank temperature
50 °C
Exchange loss
5K
Nighttime rate of heat pump
Time for nighttime rate
Electrical auxiliary heating necessary
no
5 - 19 o'clock
14,0 pence/kWh
19 - 5 o'clock
14,0 pence/kWh
like heat pump: yes
-- pence/kWh
Heating element for monoenergetic operation
Like heat pump: yes
-- pence/kWh
Heating element for post heating of hot water
like heat pump: yes
-- pence/kWh
Heat circulation pump(s)
Used Panasonic heat pump
French (Panasonic)
Description
WH-SXF12D6E5
Sanitary tank
WH-TD30E3E5
Heat pump type
air / water
Climatic data
Wattage at 2/35
heat: 11,7 kW, electric: 3,4 kW
Climatic location
Recommended flow-through of air
4800,0 m3/h
Monthly average temperatures in °C
Jan
3,4
Jul
16,0
Max. flow temperature
55 °C
Feb
3,6
Aug
15,9
Mode of operation
monovalent
Mar
5,7
Sep
13,7
Design/Bivalent temperature
-5,0 °C
Apr
8,0
Oct
10,4
Number of heat pumps used
1
May
11,2
Nov
6,7
Wattage of fan (included in heat
pump performance data: yes)
60 W
Jun
14,1
Dec
4,6
Wattage of heat circulation pump(s)
180 W
* Calculations were carried using Panasonic's Aquarea Designer software, available from the PRO Club website (www.panasonicproclub.com).
58
Reims (FR)
AQUAREA
Calculation results
Monthly heat consumption in kWh
Annual energy costs
Caused by heat producers
Heat pump
1.600 €
Hot water heating rod
0€
Caused by heat consumers
Space heating
1.220 €
Service hot water
225 €
Heat circulation pump(s)
155 €
Total
4500
4000
3500
3000
kWh 2500
2000
1500
1000
500
0
Jan
1.600 €
Feb
Mar
Apr
May
Jun
jul
Aug
Oct
Nov
Dec
Hot water
Heating
Aquarea energy coverage
Sep
12
10
8
kW
Enviroment energy
6
4
Drive energy
2
0
-5
-1
3
7
11
Outdoor temperature (°C)
Additional energy
Comparison of running costs
Operational costs
Type of heating
Price in
pence/kWh
Efficiency [%] Additional
Total costs
costs in €/year in €/year
Heat pump
-
-
0
1.600
Oil
6,5
85
0
3.050
Gas
4,0
90
0
1.868
Wood heating
5,0
80
0
2.539
Electric night storage heater 12,0
100
0
4.455
Electric heating element
100
0
5.197
14,0
4500
4000
3500
kW
3000
2500
2000
1500
1000
500
0
Aquarea
Heat pump
Comparison of CO2 emissions
18000
16000
14000
12000
kg/year 10000
8000
6000
4000
2000
0
Oil
Gas
Wood
heating
Night
heater
Electr.
Direct
Comparison of CO2 savings
12000
10000
8000
kg/year 6000
4000
2000
0
Aquarea
Heat pump
Oil
Oil
Gas
Night heater
Gas
Night heater
Electr. Direct
Electr. Direct
59
Heating capacity table based on outlet temperature and outside temperature
Heating capacity Curve
Aquarea. High Performance. Bi-Bloc Single Phase. Heating Only - SDF. Heating and Cooling - SDC. 3 and 5kW
WH-SDF03E3E5 / WH-SDC03E3E5
Tamb
HC
IP
COP
HC
IP
COP
HC
IP
COP
LWC
30
30
30
35
35
35
40
40
40
3,20
1,39
2,30
3,20
1,39
2,30
3,00
1,64
1,83
-15
3,20
1,19
2,69
3,20
1,19
2,69
3,20
1,48
2,16
-7
3,20
0,90
3,56
3,20
0,90
3,56
3,20
1,16
2,76
2
3,20
0,64
5,00
3,20
0,64
5,00
3,20
0,89
3,60
7
HC
45
3,00
3,20
3,20
3,20
IP
45
1,64
1,48
1,16
0,89
COP
45
1,83
2,16
2,76
3,60
HC
50
2,75
3,20
3,20
3,20
IP
50
1,92
1,86
1,49
1,20
COP
50
1,43
1,72
2,15
2,67
HC
55
2,75
3,20
3,20
3,20
IP
55
1,92
1,86
1,49
1,20
COP
55
1,43
1,72
2,15
2,67
WH-SDF05E3E5 / WH-SDC05E3E5
Tamb
HC
IP
LWC
30
30
4,20
1,94
-15
4,20
1,62
-7
4,20
1,35
2
5,00
1,08
7
HC
45
3,40
3,80
4,20
5,00
IP
45
1,98
1,82
1,65
1,48
COP
45
1,72
2,09
2,55
3,38
HC
50
3,00
3,55
4,10
5,00
IP
50
2,12
2,08
2,07
1,89
COP
50
1,42
1,71
1,98
2,65
HC
55
3,00
3,55
4,10
5,00
IP
55
2,12
2,08
2,07
1,89
COP
55
1,42
1,71
1,98
2,65
COP
30
2,16
2,59
3,11
4,63
HC
35
4,20
4,20
4,20
5,00
IP
35
1,94
1,62
1,35
1,08
COP
35
2,16
2,59
3,11
4,63
HC
40
3,4
3,8
4,2
5,00
IP
40
1,98
1,82
1,65
1,48
COP
40
1,72
2,09
2,55
3,38
Cooling Capacity Curve
Aquarea. High Performance. Bi-Bloc Single Phase. Heating and Cooling - SDC. 3 and 5kW
MODELS
WH-SDC03E3E5
Tamb
CC
IP
CC
IP
CC
LWC
7
7
14
14
18
2,40
0,42
4,40
0,73
3,70
18
3,20
0,73
4,10
0,86
3,50
25
3,20
1,04
3,90
1,07
3,30
35
2,90
1,20
3,50
1,20
3,00
43
WH-SDC05E3E5
CC
IP
7
7
4,50
0,89
5,00
1,43
4,50
1,67
3,30
1,53
IP
18
0,49
0,59
0,74
0,88
CC
14
5,00
6,30
5,50
4,10
IP
14
0,90
1,50
1,68
1,52
CC
18
5,70
5,40
5,00
4,40
IP
18
0,90
1,06
1,33
1,53
Tamb: Ambient Temperature (°C). LWC: Leaving Water Condenser Temperature (°C). HC: Heating capacity (kW). CC: Cooling Capacity (kW). IP: Power Input (kW)
This data is measured by Panasonic in accordance with EN14511-2 standard. This data is for reference purpose only, and does not guarantee the performance.
Hydraulic Pump Performance. Constant Pressure Head Difference ( p-c). 3 and 5kW
Hydraulic Pump Performance. Variable Pressure Head Difference ( p-v). 3 and 5kW
WH-SDF03E3E5 // WH-SDF05E3E5 // WH-SDC03E3E5 // WH-SDC05E3E5
WH-SDF03E3E5 // WH-SDF05E3E5 // WH-SDC03E3E5 // WH-SDC05E3E5
40
6&7
60
5
50
4
40
3
30
2
20
1
External Static Pressure (kPa)
External Static Pressure (kPa)
70
6
30
5
4
20
3
2
10
10
0
0
10
20
30
Water Flow Rate (L/min)
A p-c
When pressure loss of system increased, pump speed will be reduced for maintain constant pressure.
60
40
0
0
10
20
30
Water Flow Rate (L/min)
A p-v
When pressure loss of system increased, pump speed will be reduced for maintain pressure according to water flow rate.
AQUAREA
Heating capacity Curve
Aquarea. High Performance. Mono-Bloc Single Phase. Heating Only - MDF. Heating and Cooling - MDC. 5, 6 and 9kW
WH-MDC05F3E5
Tamb
HC
IP
COP
HC
IP
COP
HC
IP
COP
HC
LWC
30
30
30
35
35
35
40
40
40
45
1,82
2,75
5,00
1,95
2,56
5,00
2,20
2,27
5,00
5,00
-15
4,50
1,44
3,13
4,50
1,51
2,98
4,50
1,64
2,74
4,50
-7
4,80
1,22
3,93
4,80
1,28
3,75
4,80
1,40
3,43
4,50
2
5,00
0,91
5,49
5,00
0,99
5,08
5,00
1,13
4,42
5,00
7
5,00
0,67
7,46
5,00
0,71
7,04
5,00
0,78
6,41
5,00
25
IP
45
2,45
1,78
1,52
1,26
0,86
COP
45
2,04
2,53
2,96
3,97
5,81
HC
50
5,00
4,50
4,30
5,00
5,00
IP
50
2,70
1,94
1,57
1,44
0,98
COP
50
1,85
2,32
2,14
3,47
5,10
HC
55
5,00
4,30
4,00
5,00
5,00
IP
55
2,95
2,12
1,72
1,63
1,10
COP
55
1,69
2,03
2,33
3,07
4,55
WH-MDF06E3E5 / WH-MDC06E3E5
Tamb
HC
IP
COP
LWC
30
30
30
2,50
2,46
6,15
-15
5,18
1,68
3,09
-7
5,00
1,23
4,08
2
6,00
1,13
5,33
7
7,30
0,78
9,42
25
HC
35
5,90
5,15
5,00
6,00
7,10
IP
35
2,66
1,92
1,45
1,35
0,93
COP
35
2,22
2,68
3,45
4,46
7,63
HC
40
5,65
5,13
5,00
6,00
6,90
IP
40
2,82
2,17
1,68
1,58
1,09
COP
40
2,00
2,37
2,99
3,81
6,36
HC
45
5,40
5,10
5,00
6,00
6,70
IP
45
2,98
2,41
1,90
1,80
1,24
COP
45
1,81
2,12
2,63
3,33
5,40
HC
50
5,20
5,45
5,00
6,00
6,50
IP
50
3,15
2,81
2,19
2,09
1,41
COP
50
1,65
1,94
2,28
2,87
4,61
HC
55
5,00
5,80
5,00
6,00
6,30
IP
55
3,32
3,20
2,48
2,38
1,58
COP
55
1,51
1,81
2,02
2,52
3,99
WH-MDF09E3E5 / WH-MDC09E3E5
Tamb
HC
IP
COP
LWC
30
30
30
7,90
3,62
2,19
-15
7,80
3,38
2,31
-7
7,00
2,01
3,49
2
9,00
1,87
4,83
7
9,00
0,99
9,09
25
HC
35
7,60
7,70
2,45
9,00
9,00
IP
35
3,77
3,63
2,37
2,17
1,31
COP
35
2,02
2,12
3,14
4,16
6,87
HC
40
7,30
7,60
7,00
9,00
9,00
IP
40
3,93
3,88
2,60
2,48
1,63
COP
40
1,86
1,96
2,70
3,64
5,52
HC
45
7,00
7,50
7,00
9,00
9,00
IP
45
4,08
4,13
2,89
2,78
1,95
COP
45
1,72
1,82
2,42
3,24
4,62
HC
50
6,45
7,55
7,00
8,95
9,00
IP
50
4,06
4,59
3,37
3,31
2,20
COP
50
1,59
1,64
2,08
2,70
4,09
HC
55
5,90
7,60
7,00
8,90
9,00
IP
55
4,03
5,05
3,85
3,84
2,45
COP
55
1,46
1,50
1,82
2,32
3,67
Aquarea. High Performance. Mono-Bloc Single Phase. Heating and Cooling - MDC. 5, 6 and 9kW
MODELS WH-MDC05F3E5
WH-MDC06E3E5
Tamb
CC
IP
CC
IP
CC
IP
CC
IP
LWC
7
7
14
14
18
18
7
7
1,95
0,45
2,20
0, 45
2,45
0,50
4,64
0,91
18
5,00
1,25
6,30
1,20
6,30
0,80
5,85
1,43
25
4,50
1,35
5,10
1,50
5,00
1,00
5,50
2,03
35
3,75
1,75
4,50
1,80
4,25
1,20
4,56
2,34
43
CC
14
5,83
9,55
6,70
6,31
IP
14
0,99
1,73
2,06
2,47
CC
18
6,74
9,81
7,30
7,14
IP
18
0,94
1,68
2,05
2,45
WH-MDC09E3E5
CC
IP
7
7
5,36
1,05
6,44
1,85
7,00
2,90
5,32
3,18
CC
14
6,12
10,50
8,40
6,34
IP
14
1,08
2,51
2,95
2,48
CC
18
7,02
11,16
9,00
6,78
IP
18
1,08
2,52
3,00
2,46
Cooling Capacity Curve
Tamb: Ambient Temperature (°C). LWC: Leaving Water Condenser Temperature (°C). HC: Heating capacity (kW). CC: Cooling Capacity (kW). IP: Power Input (kW)
This data is measured by Panasonic in accordance with EN14511-2 standard. This data is for reference purpose only, and does not guarantee the performance.
Hydraulic pump performance of the F type Heat Pumps: A class pump F (5 kW and 16 kW)
110
100
90
80
70
60
50
40
30
20
10
0
7
6
5
4
Power consumption (W)
External Static Pressure (kPa)
Hydraulic pump performance of the F type Heat Pumps: A class pump F (5 kW and 16 kW)
3
2
1
0
10
Min
20
30
Water Flow Rate (L/min)
Pump Speed 1
Pump Speed 2
40
200
190
180
170
160
150
140
130
120
110
100
90
80
70
60
50
40
30
20
10
0
7
4
3
1
0
50
10
20
Pump Speed 3
Pump Speed 4
Pump Speed 5
30
Pump Speed 6
WH-MDC06E3E5
External Static Pressure (kPa)
External Static Pressure (kPa)
4
40
3
30
2
20
1
50
60
70
Max
WH-MDC06E3E5
5
50
40
Hydraulic Pump Performance. Variable Pressure Head Difference (Δp-c)
6&7
60
2
Water Flow Rate (L/min)
Hydraulic Pump Performance. Constant Pressure Head Difference (Δp-c)
70
5
6
40
6
30
5
4
20
3
2
10
10
0
0
10
20
30
Water Flow Rate (L/min)
A Δp-c
When pressure loss of system increased, pump speed will be reduced for maintain constant pressure.
40
0
0
10
20
30
Water Flow Rate (L/min)
A Δp-c
When pressure loss of system increased, pump speed will be reduced for maintain pressure according to water flow rate.
61
Heating capacity table based on outlet temperature and outside temperature
Heating capacity Curve
Aquarea. High Performance. Bi-Bloc Single Phase / Three Phase. Heating and Cooling. SDC
WH-SDC07F3E5
Tamb
HC
IP
COP
HC
IP
COP
HC
LWC
30
30
30
35
35
35
40
4,60
1,85
2,49
4,60
1,98
2,32
4,60
-15
5,15
1,78
2,89
5,15
1,92
2,68
5,08
-7
6,70
1,81
3,70
6,55
1,96
3,34
6,58
2
7,00
1,41
4,96
7,00
1,57
4,46
7,00
7
7,00
0,77
9,09
7,00
0,91
7,69
6,40
25
IP
40
2,17
2,12
2,27
1,75
1,01
COP
40
2,12
2,40
2,90
4,00
6,34
HC
45
4,60
5,00
6,60
7,00
6,10
IP
45
2,40
2,36
2,62
2,10
1,15
COP
45
1,92
2,12
2,52
3,33
5,30
HC
50
4,55
4,90
6,30
6,90
5,90
IP
50
2,66
2,45
2,88
2,28
1,31
COP
50
1,71
2,00
2,19
3,03
4,50
HC
55
4,50
4,80
6,00
6,80
5,70
IP
55
2,98
2,65
3,14
2,70
1,47
COP
55
1,51
1,81
1,91
2,52
3,88
WH-SDC09F3E5
Tamb
HC
LWC
30
6,00
-15
6,10
-7
6,80
2
9,00
7
9,00
25
IP
30
2,53
2,14
1,85
1,91
1,05
COP
30
2,37
2,85
3,68
4,71
8,57
HC
35
5,90
5,90
6,70
9,00
9,00
IP
35
2,66
2,34
2,14
2,18
1,25
COP
35
2,22
2,52
3,13
4,13
7,20
HC
40
5,50
5,85
6,70
9,00
8,40
IP
40
2,80
2,61
2,36
2,43
1,38
COP
40
1,96
2,24
2,84
3,70
6,09
HC
45
5,40
5,80
6,60
9,00
8,00
IP
45
2,98
2,88
2,62
2,79
1,57
COP
45
1,81
2,01
2,52
3,23
5,10
HC
50
5,20
5,80
6,30
8,95
7,80
IP
50
3,12
3,04
2,88
3,21
1,79
COP
50
1,67
1,91
2,19
2,79
4,36
HC
55
5,00
5,80
6,00
8,90
7,50
IP
55
3,31
3,21
3,14
3,85
2,01
COP
55
1,51
1,81
1,91
2,31
3,73
WH-SDC12F6E5
Tamb
HC
LWC
30
9,30
-15
10,40
-7
11,80
2
12,00
7
12,00
25
IP
30
3,46
3,37
3,10
2,10
1,38
COP
30
2,69
3,09
3,81
5,71
8,70
HC
35
8,90
10,00
11,40
12,00
12,00
IP
35
3,62
3,66
3,31
2,53
1,66
COP
35
2,46
2,73
3,44
4,74
7,23
HC
40
8,50
9,60
11,00
12,00
11,80
IP
40
3,79
3,86
3,53
2,96
1,94
COP
40
2,24
2,49
3,12
4,05
6,08
HC
45
8,10
9,20
10,60
12,00
11,70
IP
45
3,95
4,06
3,74
3,39
2,23
COP
45
2,05
2,27
2,83
3,54
5,25
HC
50
7,50
8,70
9,80
12,00
11,50
IP
50
4,05
4,16
3,94
3,78
2,49
COP
50
1,85
2,09
2,49
3,17
4,62
HC
55
7,00
8,20
9,10
12,00
11,40
IP
55
4,16
4,27
4,14
4,16
2,74
COP
55
1,68
1,92
2,20
2,88
4,16
WH-SDC14F6E5
Tamb
HC
LWC
30
9,90
-15
11,10
-7
12,90
2
14,00
7
14,00
25
IP
30
3,87
3,69
3,47
2,56
1,71
COP
30
2,56
3,01
3,72
5,47
8,19
HC
35
9,50
10,70
12,40
14,00
14,00
IP
35
4,01
3,96
3,69
3,07
2,06
COP
35
2,37
2,70
3,36
4,56
6,80
HC
40
9,00
10,20
11,90
14,00
14,00
IP
40
4,15
4,16
3,91
3,59
2,41
COP
40
2,17
2,45
3,04
3,90
5,81
HC
45
8,60
9,80
11,40
14,00
14,00
IP
45
4,29
4,36
4,13
4,10
2,76
COP
45
2,00
2,25
2,76
3,41
5,07
HC
50
7,90
9,10
10,40
13,60
14,00
IP
50
4,41
4,53
4,25
4,57
3,01
COP
50
1,79
2,01
2,45
2,98
4,65
HC
55
7,30
8,50
9,50
13,30
14,00
IP
55
4,52
4,70
4,36
5,04
3,40
COP
55
1,62
1,81
2,18
2,64
4,12
WH-SDC16F6E5
Tamb
HC
LWC
30
10,60
-15
11,90
-7
13,50
2
16,00
7
16,00
25
IP
30
4,09
4,03
3,74
3,21
2,31
COP
30
2,59
2,95
3,61
4,98
6,93
HC
35
10,30
11,40
13,00
16,00
16,00
IP
35
4,38
4,26
3,96
3,74
2,69
COP
35
2,35
2,68
3,28
4,28
5,95
HC
40
10,00
10,80
12,40
16,00
16,00
IP
40
4,67
4,46
4,18
4,27
3,07
COP
40
2,14
2,42
2,97
3,75
5,21
HC
45
9,70
10,30
11,90
16,00
16,00
IP
45
4,96
4,66
4,40
4,80
3,45
COP
45
1,96
2,21
2,70
3,33
4,64
HC
50
8,80
9,60
10,80
15,20
16,00
IP
50
4,94
4,81
4,46
5,11
3,67
COP
50
1,78
2,00
2,42
2,97
4,36
HC
55
7,90
9,00
9,80
14,50
15,90
IP
55
4,91
4,95
4,51
5,41
3,89
COP
55
1,61
1,82
2,17
2,68
4,09
WH-SDC09F3E8
Tamb
HC
LWC
30
8,65
-15
9,35
-7
9,31
2
9,00
7
9,00
25
IP
30
3,06
2,91
2,35
1,54
1,05
COP
30
2,83
3,21
3,96
5,84
8,57
HC
35
8,30
9,00
9,00
9,00
9,00
IP
35
3,21
3,16
2,51
1,86
1,24
COP
35
2,59
2,85
3,59
4,84
7,26
HC
40
7,95
8,85
9,00
9,00
8,73
IP
40
3,41
3,46
2,78
2,16
1,44
COP
40
2,33
2,56
3,24
4,17
6,06
HC
45
7,60
8,70
9,00
9,00
8,46
IP
45
3,61
3,76
3,05
2,46
1,64
COP
45
2,11
2,31
2,95
3,66
5,16
HC
50
7,15
8,30
8,90
9,00
8,28
IP
50
3,71
3,81
3,49
2,76
1,82
COP
50
1,93
2,18
2,55
3,26
4,55
HC
55
6,70
7,90
8,80
9,00
8,10
IP
55
3,81
3,86
3,94
3,06
2,00
COP
55
1,76
2,05
2,23
2,94
4,05
WH-SDC12F9E8
Tamb
HC
LWC
30
9,30
-15
10,40
-7
11,80
2
12,00
7
12,00
25
IP
30
3,46
3,37
3,10
2,10
1,38
COP
30
2,69
3,09
3,81
5,71
8,70
HC
35
8,90
10,00
11,40
12,00
12,00
IP
35
3,62
3,66
3,31
2,53
1,66
COP
35
2,46
2,73
3,44
4,74
7,23
HC
40
8,50
9,60
11,00
12,00
11,80
IP
40
3,79
3,86
3,53
2,96
1,94
COP
40
2,24
2,49
3,12
4,05
6,08
HC
45
8,10
9,20
10,60
12,00
11,70
IP
45
3,95
4,06
3,74
3,39
2,23
COP
45
2,05
2,27
2,83
3,54
5,25
HC
50
7,50
8,70
9,80
12,00
11,50
IP
50
4,05
4,16
3,94
3,78
2,49
COP
50
1,85
2,09
2,49
3,17
4,62
HC
55
7,00
8,20
9,10
12,00
11,40
IP
55
4,16
4,27
4,14
4,16
2,74
COP
55
1,68
1,92
2,20
2,88
4,16
WH-SDC14F9E8
Tamb
HC
LWC
30
9,90
-15
11,10
-7
12,90
2
14,00
7
14,00
25
IP
30
3,87
3,69
3,47
2,56
1,71
COP
30
2,56
3,01
3,72
5,47
8,19
HC
35
9,50
10,70
12,40
14,00
14,00
IP
35
4,01
3,96
3,69
3,07
2,06
COP
35
2,37
2,70
3,36
4,56
6,80
HC
40
9,00
10,20
11,90
14,00
14,00
IP
40
4,15
4,16
3,91
3,59
2,41
COP
40
2,17
2,45
3,04
3,90
5,81
HC
45
8,60
9,80
11,40
14,00
14,00
IP
45
4,29
4,36
4,13
4,10
2,76
COP
45
2,00
2,25
2,76
3,41
5,07
HC
50
7,90
9,10
10,40
13,60
14,00
IP
50
4,41
4,53
4,25
4,57
3,01
COP
50
1,79
2,01
2,45
2,98
4,65
HC
55
7,30
8,50
9,50
13,30
14,00
IP
55
4,52
4,70
4,36
5,04
3,40
COP
55
1,62
1,81
2,18
2,64
4,12
WH-SDC16F9E8
Tamb
HC
LWC
30
10,60
-15
11,90
-7
13,50
2
16,00
7
16,00
25
IP
30
4,09
4,03
3,74
3,21
2,31
COP
30
2,59
2,95
3,61
4,98
6,93
HC
35
10,30
11,40
13,00
16,00
16,00
IP
35
4,38
4,26
3,96
3,74
2,69
COP
35
2,35
2,68
3,28
4,28
5,95
HC
40
10,00
10,80
12,40
16,00
16,00
IP
40
4,67
4,46
4,18
4,27
3,07
COP
40
2,14
2,42
2,97
3,75
5,21
HC
45
9,70
10,30
11,90
16,00
16,00
IP
45
4,96
4,66
4,40
4,80
3,45
COP
45
1,96
2,21
2,70
3,33
4,64
HC
50
8,80
9,60
10,80
15,20
16,00
IP
50
4,94
4,81
4,46
5,11
3,67
COP
50
1,78
2,00
2,42
2,97
4,36
HC
55
7,90
9,00
9,80
14,50
15,90
IP
55
4,91
4,95
4,51
5,41
3,89
COP
55
1,61
1,82
2,17
2,68
4,09
62
AQUAREA
Cooling Capacity Curve
Aquarea. High Performance. Bi-Bloc Single Phase / Three Phase. Heating and Cooling. SDC
MODELS
WH-SDC07F3E5
WH-SDC09F3E5
WH-SDC12F6E5
WH-SDC14F6E5
Tamb
CC
IP
CC
IP
CC
IP
CC
IP
LWC
7
7
7
7
7
7
7
7
5,09
0,86
5,93
1,05
7,65
1,26
8,85
1,46
16
6,58
1,73
7,79
2,23
9,20
2,26
10,00
2,64
25
6,00
2,28
7,00
2,88
10,00
3,56
11,50
4,36
35
5,14
2,67
6,20
3,26
7,60
3,91
9,05
4,97
43
WH-SDC16F6E5
CC
IP
7
7
9,62
1,59
10,51
2,81
12,20
4,76
10,08
5,43
WH-SDC09F3E8
CC
IP
7
7
5,90
0,97
7,45
1,55
7,00
2,21
5,80
2,55
WH-SDC12F9E8
CC
IP
7
7
7,65
1,26
9,20
2,26
10,00
3,56
7,60
3,91
WH-SDC14F9E8
CC
IP
7
7
8,85
1,46
10,00
2,64
11,50
4,36
9,05
4,97
WH-SDC16F9E8
CC
IP
7
7
9,62
1,59
10,51
2,81
12,20
4,76
10,08
5,43
Tamb: Ambient Temperature (°C). LWC: Leaving Water Condenser Temperature (°C). HC: Heating capacity (kW). CC: Cooling Capacity (kW). IP: Power Input (kW)
This data is measured by Panasonic in accordance with EN14511-2 standard. This data is for reference purpose only, and does not guarantee the performance.
110
100
90
80
70
60
50
40
30
20
10
0
Min
Hydraulic pump performance of the F type Heat Pumps: A class pump F (5 kW and 16 kW)
7
6
5
4
Power consumption (W)
External Static Pressure (kPa)
Hydraulic pump performance of the F type Heat Pumps: A class pump F (5 kW and 16 kW)
3
2
1
0
10
Pump Speed 1
20
30
Water Flow Rate (L/min)
Pump Speed 2
40
50
200
190
180
170
160
150
140
130
120
110
100
90
80
70
60
50
40
30
20
10
0
7
4
5
6
3
1
0
10
20
2
30
40
50
60
70
Water Flow Rate (L/min)
Pump Speed 3
Pump Speed 4
Pump Speed 5
Pump Speed 6
Max
63
Heating capacity table based on outlet temperature and outside temperature
Heating capacity Curve
Aquarea. High Performance. Mono-Bloc Single Phase / Three Phase. Heating Only - MDF. Heating and Cooling - MDC
WH-MDC12C6E5
Tamb
HC
IP
COP
HC
IP
COP
HC
IP
COP
HC
LWC
30
30
30
35
35
35
40
40
40
45
9,30
3,50
2,66
8,90
3,66
2,43
8,50
3,83
2,22
8,10
-15
10,40
3,41
3,05
10,00
3,70
2,70
9,60
3,90
2,46
9,20
-7
11,80
3,14
3,76
11,40
3,34
3,41
11,00
3,57
3,08
10,60
2
12,00
2,14
5,61
12,00
2,57
4,67
12,00
3,00
4,00
12,00
7
12,00
1,42
8,45
12,00
1,70
7,06
11,80
1,98
5,96
11,70
25
IP
45
3,99
4,10
3,78
3,43
2,27
COP
45
2,03
2,24
2,80
3,50
5,15
HC
50
7,50
8,70
9,80
12,00
11,50
IP
50
4,09
4,20
3,98
3,82
2,53
COP
50
1,83
2,07
2,46
3,14
4,55
HC
55
7,00
8,20
9,10
12,00
11,40
IP
55
4,20
4,31
4,18
4,20
2,78
COP
55
1,67
1,90
2,18
2,86
4,10
WH-MDC14C6E5
Tamb
HC
LWC
30
9,90
-15
11,10
-7
12,90
2
14,00
7
14,00
25
IP
30
3,91
3,73
3,51
2,60
1,75
COP
30
2,53
2,98
3,68
5,38
8,00
HC
35
9,50
10,70
12,40
14,00
14,00
IP
35
4,05
4,00
3,73
3,11
2,10
COP
35
2,35
2,68
3,32
4,50
6,67
HC
40
9,00
10,20
11,90
14,00
14,00
IP
40
4,19
4,20
3,95
3,63
2,45
COP
40
2,15
2,43
3,01
3,86
5,71
HC
45
8,60
9,80
11,40
14,00
14,00
IP
45
4,33
4,40
4,17
4,14
2,80
COP
45
1,99
2,23
2,73
3,38
5,00
HC
50
7,90
9,10
10,40
13,60
14,00
IP
50
4,45
4,57
4,29
4,61
3,05
COP
50
1,78
1,99
2,42
2,95
4,59
HC
55
7,30
8,50
9,50
13,30
14,00
IP
55
4,56
4,74
4,40
5,08
3,44
COP
55
1,60
1,79
2,16
2,62
4,07
WH-MDC16C6E5
Tamb
HC
LWC
30
10,60
-15
11,90
-7
13,50
2
16,00
7
16,00
25
IP
30
4,13
4,07
3,78
3,25
2,35
COP
30
2,57
2,92
3,57
4,92
6,81
HC
35
10,30
11,40
13,00
16,00
16,00
IP
35
4,42
4,30
4,00
3,78
2,73
COP
35
2,33
2,65
3,25
4,23
5,86
HC
40
10,00
10,80
12,40
16,00
16,00
IP
40
4,71
4,50
4,22
4,31
3,11
COP
40
2,12
2,40
2,94
3,71
5,14
HC
45
9,70
10,30
11,90
16,00
16,00
IP
45
5,00
4,70
4,44
4,84
3,49
COP
45
1,94
2,19
2,68
3,31
4,58
HC
50
8,80
9,60
10,80
15,20
16,00
IP
50
4,98
4,85
4,50
5,15
3,71
COP
50
1,77
1,98
2,40
2,95
4,31
HC
55
7,90
9,00
9,80
14,50
15,90
IP
55
4,95
4,99
4,55
5,45
3,93
COP
55
1,60
1,80
2,15
2,66
4,05
WH-MDC09C3E8
Tamb
HC
LWC
30
8,65
-15
9,35
-7
9,31
2
9,00
7
9,00
25
IP
30
3,10
2,95
2,39
1,58
1,09
COP
30
2,79
3,17
3,90
5,70
8,26
HC
35
8,30
9,00
9,00
9,00
9,00
IP
35
3,25
3,20
2,55
1,90
1,28
COP
35
2,55
2,81
3,53
4,74
7,03
HC
40
7,95
8,85
9,00
9,00
8,73
IP
40
3,45
3,50
2,82
2,20
1,48
COP
40
2,30
2,53
3,19
4,09
5,90
HC
45
7,60
8,70
9,00
9,00
8,46
IP
45
3,65
3,80
3,09
2,50
1,68
COP
45
2,08
2,29
2,91
3,60
5,04
HC
50
7,15
8,30
8,90
9,00
8,28
IP
50
3,75
3,85
3,53
2,80
1,86
COP
50
1,91
2,16
2,52
3,21
4,45
HC
55
6,70
7,90
8,80
9,00
8,10
IP
55
3,85
3,90
3,98
3,10
2,04
COP
55
1,74
2,03
2,21
2,90
3,97
WH-MDC12C9E8
Tamb
HC
LWC
30
9,30
-15
10,40
-7
11,80
2
12,00
7
12,00
25
IP
30
3,50
3,41
3,14
2,14
1,42
COP
30
2,66
3,05
3,76
5,61
8,45
HC
35
8,90
10,00
11,40
12,00
12,00
IP
35
3,66
3,70
3,34
2,57
1,70
COP
35
2,43
2,70
3,41
4,67
7,06
HC
40
8,50
9,60
11,00
12,00
11,80
IP
40
3,83
3,90
3,57
3,00
1,98
COP
40
2,22
2,46
3,08
4,00
5,96
HC
45
8,10
9,20
10,60
12,00
11,70
IP
45
3,99
4,10
3,78
3,43
2,27
COP
45
2,03
2,24
2,80
3,50
5,15
HC
50
7,50
8,70
9,80
12,00
11,50
IP
50
4,09
4,20
3,98
3,82
2,53
COP
50
1,83
2,07
2,46
3,14
4,55
HC
55
7,00
8,20
9,10
12,00
11,40
IP
55
4,20
4,31
4,18
4,20
2,78
COP
55
1,67
1,90
2,18
2,86
4,10
WH-MDC14C9E8
Tamb
HC
LWC
30
9,90
-15
11,10
-7
12,90
2
14,00
7
14,00
25
IP
30
3,91
3,73
3,51
2,60
1,75
COP
30
2,53
2,98
3,68
5,38
8,00
HC
35
9,50
10,70
12,40
14,00
14,00
IP
35
4,05
4,00
3,73
3,11
2,10
COP
35
2,35
2,68
3,32
4,50
6,67
HC
40
9,00
10,20
11,90
14,00
14,00
IP
40
4,19
4,20
3,95
3,63
2,45
COP
40
2,15
2,43
3,01
3,86
5,71
HC
45
8,60
9,80
11,40
14,00
14,00
IP
45
4,33
4,40
4,17
4,14
2,80
COP
45
1,99
2,23
2,73
3,38
5,00
HC
50
7,90
9,10
10,40
13,60
14,00
IP
50
4,45
4,57
4,29
4,61
3,05
COP
50
1,78
1,99
2,42
2,95
4,59
HC
55
7,30
8,50
9,50
13,30
14,00
IP
55
4,56
4,74
4,40
5,08
3,44
COP
55
1,60
1,79
2,16
2,62
4,07
WH-MDC16C9E8
Tamb
HC
LWC
30
10,60
-15
11,90
-7
13,50
2
16,00
7
16,00
25
IP
30
4,13
4,07
3,78
3,25
2,35
COP
30
2,57
2,92
3,57
4,92
6,81
HC
35
10,30
11,40
13,00
16,00
16,00
IP
35
4,42
4,30
4,00
3,78
2,73
COP
35
2,33
2,65
3,25
4,23
5,86
HC
40
10,00
10,80
12,40
16,00
16,00
IP
40
4,71
4,50
4,22
4,31
3,11
COP
40
2,12
2,40
2,94
3,71
5,14
HC
45
9,70
10,30
11,90
16,00
16,00
IP
45
5,00
4,70
4,44
4,84
3,49
COP
45
1,94
2,19
2,68
3,31
4,58
HC
50
8,80
9,60
10,80
15,20
16,00
IP
50
4,98
4,85
4,50
5,15
3,71
COP
50
1,77
1,98
2,40
2,95
4,31
HC
55
7,90
9,00
9,80
14,50
15,90
IP
55
4,95
4,99
4,55
5,45
3,93
COP
55
1,60
1,80
2,15
2,66
4,05
Hydraulic Pump Performance. 9 kW single phase
Hydraulic Pump Performance. MDC 12 to MDC 16 single phase and all MDC three phase
External Static Pressure (kPa)
External Static Pressure (kPa)
90
70
60
50
40
30
20
10
0
0
5
10
15
20
25
30
35
80
70
60
50
40
30
20
10
0
0
Water Flow Rate (L/min)
Low Speed (I)
64
Medium Speed (II)
High Speed (III)
10
20
30
40
Water Flow Rate (L/min)
Pump Speed (I)
Pump Speed (II)
Pump Speed (III)
50
60
70
AQUAREA
Cooling Capacity Curve
Aquarea. High Performance. Mono-Bloc Single Phase / Three Phase. Cooling. MDC
Models
WH-MDC09
WH-MDC12
Tamb
CC
IP
EER
CC
5,90
1,01
5,84
7,65
16
7,45
1,59
4,69
9,20
25
7,00
2,25
3,11
10,00
35
5,80
2,59
2,24
7,60
43
IP
1,30
2,30
3,60
3,95
EER
5,88
4,00
2,78
1,92
WH-MDC14
CC
8,85
10,00
11,50
9,05
IP
1,50
2,68
4,40
5,01
EER
5,90
3,73
2,61
1,81
WH-MDC16
CC
9,62
10,51
12,20
10,08
IP
1,63
2,85
4,80
5,47
EER
5,90
3,69
2,54
1,84
Heating Capacity Curve
Aquarea T-CAP. Mono-Bloc Single Phase / Three Phase. Heating. MXF / MXC
WH-MXC09D3E5
Tamb
HC
IP
COP
HC
IP
COP
LWC
30
30
30
35
35
35
9,00
3,28
2,74
9,00
3,55
2,54
-15
9,00
2,75
3,27
9,00
3,20
2,81
-7
9,00
2,40
3,75
9,00
2,55
3,53
2
9,00
1,68
5,36
9,00
1,90
4,74
7
13,60
1,54
8,83
13,60
1,75
7,77
25
HC
40
9,00
9,00
9,00
9,00
13,20
IP
40
3,95
3,66
2,82
2,20
1,97
COP
40
2,28
2,46
3,19
4,09
6,70
HC
45
9,00
9,00
9,00
9,00
12,80
IP
45
4,34
4,11
3,09
2,50
2,18
COP
45
2,07
2,19
2,91
3,60
5,87
HC
50
9,00
9,00
9,00
9,00
12,00
IP
50
4,77
4,31
3,60
2,80
2,45
COP
50
1,89
2,09
2,50
3,21
4,90
HC
55
9,00
9,00
9,00
9,00
11,20
IP
55
5,20
4,50
4,11
3,10
2,71
COP
55
1,73
2,00
2,19
2,90
4,13
WH-MXC12D6E5
Tamb
HC
LWC
30
12,00
-15
12,00
-7
12,00
2
12,00
7
13,60
25
IP
30
4,79
3,89
3,23
2,22
1,59
COP
30
2,51
3,08
3,72
5,41
8,55
HC
35
12,00
12,00
12,00
12,00
13,60
IP
35
5,00
4,45
3,53
2,57
1,80
COP
35
2,40
2,70
3,40
4,67
7,56
HC
40
11,50
12,00
12,00
12,00
13,40
IP
40
5,21
5,02
3,91
3,00
2,14
COP
40
2,21
2,39
3,07
4,00
6,26
HC
45
11,00
12,00
12,00
12,00
13,20
IP
45
5,42
5,58
4,29
3,43
2,47
COP
45
2,03
2,15
2,80
3,50
5,34
HC
50
10,70
12,00
12,00
12,00
12,60
IP
50
5,86
5,94
4,90
3,82
2,70
COP
50
1,83
2,02
2,45
3,14
4,67
HC
55
10,50
12,00
12,00
12,00
12,00
IP
55
6,30
6,30
5,51
4,20
2,93
COP
55
1,67
1,90
2,18
2,86
4,10
WH-MXC09D3E8
Tamb
HC
LWC
30
9,00
-15
9,00
-7
9,00
2
9,00
7
13,60
25
IP
30
3,28
2,75
2,40
1,68
1,54
COP
30
2,74
3,27
3,75
5,36
8,83
HC
35
9,00
9,00
9,00
9,00
13,60
IP
35
3,55
3,20
2,55
1,90
1,75
COP
35
2,54
2,81
3,53
4,74
7,77
HC
40
9,00
9,00
9,00
9,00
13,20
IP
40
3,95
3,66
2,82
2,20
1,97
COP
40
2,28
2,46
3,19
4,09
6,70
HC
45
9,00
9,00
9,00
9,00
12,80
IP
45
4,34
4,11
3,09
2,50
2,18
COP
45
2,07
2,19
2,91
3,60
5,87
HC
50
9,00
9,00
9,00
9,00
12,00
IP
50
4,77
4,31
3,60
2,80
2,45
COP
50
1,89
2,09
2,50
3,21
4,90
HC
55
9,00
9,00
9,00
9,00
11,20
IP
55
5,20
4,50
4,11
3,10
2,71
COP
55
1,73
2,00
2,19
2,90
4,13
WH-MXC12D9E8
Tamb
HC
LWC
30
12,00
-15
12,00
-7
12,00
2
12,00
7
13,60
25
IP
30
4,79
3,89
3,23
2,22
1,59
COP
30
2,51
3,08
3,72
5,41
8,55
HC
35
12,00
12,00
12,00
12,00
13,60
IP
35
5,00
4,45
3,53
2,57
1,80
COP
35
2,40
2,70
3,40
4,67
7,56
HC
40
12,00
12,00
12,00
12,00
13,40
IP
40
5,45
5,02
3,91
3,00
2,14
COP
40
2,20
2,39
3,07
4,00
6,26
HC
45
12,00
12,00
12,00
12,00
13,20
IP
45
5,90
5,58
4,29
3,43
2,47
COP
45
2,03
2,15
2,80
3,50
5,34
HC
50
11,50
12,00
12,00
12,00
12,60
IP
50
6,28
5,94
4,90
3,82
2,70
COP
50
1,83
2,02
2,45
3,14
4,67
HC
55
11,10
12,00
12,00
12,00
12,00
IP
55
6,66
6,30
5,51
4,20
2,93
COP
55
1,67
1,90
2,18
2,86
4,10
Cooling Capacity Curve
Aquarea T-CAP. Mono-Bloc Single Phase / Three Phase. Cooling. MXC
MODELS
WH-MXC09
Tamb
CC
IP
7,00
1,40
16
7,65
1,95
25
7,00
2,25
35
6,25
2,70
43
WH-MXC12
CC
7,50
8,90
10,00
8,00
EER
5,00
3,92
3,11
2,31
IP
1,45
2,20
3,60
3,05
EER
5,17
4,05
2,78
2,62
Tamb: Ambient Temperature (°C). LWC: Leaving Water Condenser Temperature (°C). HC: Heating capacity (kW). CC: Cooling Capacity (kW). IP: Power Input (kW)
This data is measured by Panasonic in accordance with EN14511-2 standard. This data is for reference purpose only, and does not guarantee the performance.
Hydraulic Pump Performance. MXC 12 to MXC 16 single phase and all MXC three phase
External Static Pressure (kPa)
90
80
70
60
50
40
30
20
10
0
0
10
20
30
40
50
60
70
Water Flow Rate (L/min)
Pump Speed (I)
Pump Speed (II)
Pump Speed (III)
65
Heating capacity table based on outlet temperature and outside temperature
Heating Capacity Curve
Aquarea T-CAP. Bi-Bloc Single Phase / Three Phase. Heating and Cooling. SXC
WH-SXC09F3E5
Tamb
HC
IP
COP
HC
IP
COP
LWC
30
30
30
35
35
35
9,00
3,24
2,78
9,00
3,51
2,56
-15
9,00
2,71
3,32
9,00
3,16
2,85
-7
9,00
2,36
3,81
9,00
2,51
3,59
2
9,00
1,64
5,49
9,00
1,86
4,84
7
13,60
1,50
9,07
13,60
1,71
7,95
25
HC
40
9,00
9,00
9,00
9,00
13,20
IP
40
3,91
3,62
2,78
2,16
1,93
COP
40
2,30
2,49
3,24
4,17
6,84
HC
45
9,00
9,00
9,00
9,00
12,80
IP
45
4,30
4,07
3,05
2,46
2,14
COP
45
2,09
2,21
2,95
3,66
5,98
HC
50
9,00
9,00
9,00
9,00
12,00
IP
50
4,73
4,27
3,56
2,76
2,41
COP
50
1,90
2,11
2,53
3,26
4,98
HC
55
9,00
9,00
9,00
9,00
11,20
IP
55
5,16
4,46
4,07
3,06
2,67
COP
55
1,74
2,02
2,21
2,94
4,19
WH-SXC12F6E5
Tamb
HC
LWC
30
12,00
-15
12,00
-7
12,00
2
12,00
7
13,60
25
IP
30
4,75
3,85
3,19
2,18
1,55
COP
30
2,53
3,12
3,76
5,50
8,77
HC
35
12,00
12,00
12,00
12,00
13,60
IP
35
4,96
4,41
3,49
2,53
1,76
COP
35
2,42
2,72
3,44
4,74
7,73
HC
40
11,50
12,00
12,00
12,00
13,40
IP
40
5,17
4,98
3,87
2,96
2,10
COP
40
2,22
2,41
3,10
4,05
6,38
HC
45
11,00
12,00
12,00
12,00
13,20
IP
45
5,38
5,54
4,25
3,39
2,43
COP
45
2,04
2,17
2,82
3,54
5,43
HC
50
10,70
12,00
12,00
12,00
12,60
IP
50
5,82
5,90
4,86
3,78
2,66
COP
50
1,84
2,03
2,47
3,17
4,74
HC
55
10,50
12,00
12,00
12,00
12,00
IP
55
6,26
6,26
5,47
4,16
2,89
COP
55
1,68
1,92
2,19
2,88
4,15
WH-SXC09F3E8
Tamb
HC
LWC
30
9,00
-15
9,00
-7
9,00
2
9,00
7
13,60
25
IP
30
3,24
2,71
2,36
1,64
1,50
COP
30
2,78
3,32
3,81
5,49
9,07
HC
35
9,00
9,00
9,00
9,00
13,60
IP
35
3,51
3,16
2,51
1,86
1,71
COP
35
2,56
2,85
3,59
4,84
7,95
HC
40
9,00
9,00
9,00
9,00
13,20
IP
40
3,91
3,62
2,78
2,16
1,93
COP
40
2,30
2,49
3,24
4,17
6,84
HC
45
9,00
9,00
9,00
9,00
12,80
IP
45
4,30
4,07
3,05
2,46
2,14
COP
45
2,09
2,21
2,95
3,66
5,98
HC
50
9,00
9,00
9,00
9,00
12,00
IP
50
4,73
4,27
3,56
2,76
2,41
COP
50
1,90
2,11
2,53
3,26
4,98
HC
55
9,00
9,00
9,00
9,00
11,20
IP
55
5,16
4,46
4,07
3,06
2,67
COP
55
1,74
2,02
2,21
2,94
4,19
WH-SXC12F9E8
Tamb
HC
LWC
30
12,00
-15
12,00
-7
12,00
2
12,00
7
13,60
25
IP
30
4,75
3,85
3,19
2,18
1,55
COP
30
2,53
3,12
3,76
5,50
8,77
HC
35
12,00
12,00
12,00
12,00
13,60
IP
35
4,96
4,41
3,49
2,53
1,76
COP
35
2,42
2,72
3,44
4,74
7,73
HC
40
12,00
12,00
12,00
12,00
13,40
IP
40
5,41
4,98
3,87
2,96
2,10
COP
40
2,22
2,41
3,10
4,05
6,38
HC
45
12,00
12,00
12,00
12,00
13,20
IP
45
5,86
5,54
4,25
3,39
2,43
COP
45
2,05
2,17
2,82
3,54
5,43
HC
50
11,50
12,00
12,00
12,00
12,60
IP
50
6,24
5,90
4,86
3,78
2,66
COP
50
1,84
2,03
2,47
3,17
4,74
HC
55
11,10
12,00
12,00
12,00
12,00
IP
55
6,62
6,26
5,47
4,16
2,89
COP
55
1,68
1,92
2,19
2,88
4,15
WH-SXC16F9E8
Tamb
HC
LWC
30
16,00
-15
16,00
-7
16,00
2
16,00
7
16,00
25
IP
30
6,50
5,85
4,59
3,21
1,90
COP
30
2,46
2,74
3,49
4,98
8,42
HC
35
16,00
16,00
16,00
16,00
16,00
IP
35
6,89
6,42
5,16
3,74
2,40
COP
35
2,32
2,49
3,10
4,28
6,67
HC
40
16,00
16,00
16,00
16,00
16,00
IP
40
7,50
7,00
5,74
4,27
2,90
COP
40
2,13
2,29
2,79
3,75
5,52
HC
45
16,00
16,00
16,00
16,00
16,00
IP
45
8,10
7,57
6,31
4,80
3,40
COP
45
1,98
2,11
2,54
3,33
4,71
HC
50
15,60
16,00
16,00
16,00
16,00
IP
50
8,76
8,31
7,10
5,51
3,86
COP
50
1,78
1,93
2,26
2,91
4,15
HC
55
15,20
16,00
16,00
16,00
16,00
IP
55
9,41
9,05
7,88
6,21
4,31
COP
55
1,62
1,77
2,03
2,58
3,71
Cooling Capacity Curve
Aquarea T-CAP. Bi-Bloc Single Phase / Three Phase. Cooling. SXC
Models
WH-SXC09
Tamb
CC
IP
7,00
1,36
16
7,65
1,91
25
7,00
2,21
35
6,25
2,66
43
WH-SXC12
CC
7,50
8,90
10,00
8,00
EER
5,15
4,01
3,17
2,35
IP
1,41
2,16
3,56
3,01
WH-SXC16
CC
9,62
10,51
12,20
10,08
EER
5,32
4,12
2,81
2,66
IP
1,59
2,81
4,76
5,43
EER
6,05
3,74
2,56
1,86
Tamb: Ambient Temperature (°C). LWC: Leaving Water Condenser Temperature (°C). HC: Heating capacity (kW). CC: Cooling Capacity (kW). IP: Power Input (kW)
This data is measured by Panasonic in accordance with EN14511-2 standard. This data is for reference purpose only, and does not guarantee the performance.
110
100
90
80
70
60
50
40
30
20
10
0
Min
66
Hydraulic pump performance of the F type Heat Pumps: A class pump F (5 kW and 16 kW)
7
6
5
4
Power consumption (W)
External Static Pressure (kPa)
Hydraulic pump performance of the F type Heat Pumps: A class pump F (5 kW and 16 kW)
3
2
1
0
10
Pump Speed 1
20
30
Water Flow Rate (L/min)
Pump Speed 2
40
50
200
190
180
170
160
150
140
130
120
110
100
90
80
70
60
50
40
30
20
10
0
7
4
3
1
0
10
20
2
30
40
Water Flow Rate (L/min)
Pump Speed 3
Pump Speed 4
5
6
Pump Speed 5
Pump Speed 6
Max
50
60
70
AQUAREA
Heating Capacity Curve
Aquarea HT. Bi-Bloc Single Phase / Three Phase. Heating Only - SHF
WH-SHF09F3E5
Tamb
HC
IP
COP HC
IP
COP HC
LWC
30
30
30
35
35
35
40
9,00
3,46
2,60
9,00
3,71
2,43
8,90
-15
9,00
3,06
2,94
9,00
3,29
2,74
9,00
-7
9,00
2,43
3,70
9,00
2,61
3,45
9,00
2
9,00
1,82
4,95
9,00
1,94
4,64
9,00
7
12,00 1,66
7,23
12,00 1,76
6,82
12,00
25
IP
40
4,01
3,56
2,91
2,21
2,01
COP
40
2,22
2,53
3,09
4,07
5,97
HC
45
8,80
8,90
9,00
9,00
10,80
IP
45
4,26
3,83
3,21
2,46
2,14
COP
45
2,07
2,32
2,80
3,66
5,05
HC
50
8,60
8,90
9,00
9,00
10,60
IP
50
4,61
4,11
3,55
2,76
2,46
COP
50
1,87
2,17
2,54
3,26
4,31
HC
55
8,50
8,90
9,00
9,00
10,20
IP
55
4,91
4,46
3,88
3,12
2,66
COP
55
1,73
2,00
2,32
2,88
3,83
HC
60
8,00
8,90
9,00
9,00
10,00
IP
60
5,06
4,96
4,35
3,46
2,91
COP
60
1,58
1,79
2,07
2,60
3,44
HC
65
7,80
8,90
9,00
9,00
9,80
IP
65
5,86
5,46
4,76
3,96
3,31
COP
65
1,33
1,63
1,89
2,27
2,96
WH-SHF12F6E5
Tamb
LWC
-15
-7
2
7
25
HC
30
12,00
12,00
12,00
12,00
12,00
IP
30
5,16
4,43
3,42
2,52
1,66
COP
30
2,33
2,71
3,51
4,76
7,23
HC
35
12,00
12,00
12,00
12,00
12,00
IP
35
5,53
4,76
3,68
2,69
1,76
COP
35
2,17
2,52
3,26
4,46
6,82
HC
40
11,00
11,50
11,50
12,00
12,00
IP
40
5,51
4,91
3,86
3,06
2,01
COP
40
2,00
2,34
2,98
3,92
5,97
HC
45
10,80
11,20
11,30
12,00
12,00
IP
45
5,49
5,06
4,14
3,44
2,41
COP
45
1,97
2,21
2,73
3,49
4,98
HC
50
10,30
10,80
11,00
12,00
12,00
IP
50
5,63
5,16
4,51
3,81
2,64
COP
50
1,83
2,09
2,44
3,15
4,55
HC
55
9,70
10,10
10,80
12,00
12,00
IP
55
5,76
5,28
4,86
4,28
2,96
COP
55
1,68
1,91
2,22
2,80
4,05
HC
60
9,00
9,85
10,65
12,00
12,00
IP
60
6,01
5,66
5,31
4,86
3,41
COP
60
1,50
1,74
2,01
2,47
3,52
HC
65
8,00
9,60
10,30
12,00
12,00
IP
65
6,11
5,91
5,59
5,41
3,86
COP
65
1,31
1,62
1,84
2,22
3,11
WH-SHF09F3E8
Tamb
LWC
-15
-7
2
7
25
HC
30
9,00
9,00
9,00
9,00
12,00
IP
30
3,46
3,06
2,43
1,82
1,66
COP
30
2,60
2,94
3,70
4,95
7,23
HC
35
9,00
9,00
9,00
9,00
12,00
IP
35
3,71
3,29
2,61
1,94
1,76
COP
35
2,43
2,74
3,45
4,64
6,82
HC
40
8,90
9,00
9,00
9,00
12,00
IP
40
4,01
3,56
2,91
2,21
2,01
COP
40
2,22
2,53
3,09
4,07
5,97
HC
45
8,80
8,90
9,00
9,00
10,80
IP
45
4,26
3,83
3,21
2,46
2,14
COP
45
2,07
2,32
2,80
3,66
5,05
HC
50
8,60
8,90
9,00
9,00
10,60
IP
50
4,61
4,11
3,55
2,76
2,46
COP
50
1,87
2,17
2,54
3,26
4,31
HC
55
8,50
8,90
9,00
9,00
10,20
IP
55
4,91
4,46
3,88
3,12
2,66
COP
55
1,73
2,00
2,32
2,88
3,83
HC
60
8,00
8,90
9,00
9,00
10,00
IP
60
5,06
4,96
4,35
3,46
2,91
COP
60
1,58
1,79
2,07
2,60
3,44
HC
65
7,80
8,90
9,00
9,00
9,80
IP
65
5,86
5,46
4,76
3,96
3,31
COP
65
1,33
1,63
1,89
2,27
2,96
WH-SHF12F9E8
Tamb
LWC
-15
-7
2
7
25
HC
30
12,00
12,00
12,00
12,00
12,00
IP
30
5,16
4,43
3,42
2,52
1,66
COP
30
2,33
2,71
3,51
4,76
7,23
HC
35
12,00
12,00
12,00
12,00
12,00
IP
35
5,53
4,76
3,68
2,69
1,76
COP
35
2,17
2,52
3,26
4,46
6,82
HC
40
11,00
11,50
11,50
12,00
12,00
IP
40
5,51
4,91
3,86
3,06
2,01
COP
40
2,00
2,34
2,98
3,92
5,97
HC
45
10,80
11,20
11,30
12,00
12,00
IP
45
5,49
5,06
4,14
3,44
2,41
COP
45
1,97
2,21
2,73
3,49
4,98
HC
50
10,30
10,80
11,00
12,00
12,00
IP
50
5,63
5,16
4,51
3,81
2,64
COP
50
1,83
2,09
2,44
3,15
4,55
HC
55
9,70
10,10
10,80
12,00
12,00
IP
55
5,76
5,28
4,86
4,28
2,96
COP
55
1,68
1,91
2,22
2,80
4,05
HC
60
9,00
9,85
10,65
12,00
12,00
IP
60
6,01
5,66
5,31
4,86
3,41
COP
60
1,50
1,74
2,01
2,47
3,52
HC
65
8,00
9,60
10,30
12,00
12,00
IP
65
6,11
5,91
5,59
5,41
3,86
COP
65
1,31
1,62
1,84
2,22
3,11
Tamb: Ambient Temperature (°C). LWC: Leaving Water Condenser Temperature (°C). HC: Heating capacity (kW). IP: Power Input (kW)
This data is measured by Panasonic in accordance with EN14511-2 standard. This data is for reference purpose only, and does not guarantee the performance.
110
100
90
80
70
60
50
40
30
20
10
0
Min
Hydraulic pump performance of the F type Heat Pumps: A class pump F (5 kW and 16 kW)
7
6
5
4
Power consumption (W)
External Static Pressure (kPa)
Hydraulic pump performance of the F type Heat Pumps: A class pump F (5 kW and 16 kW)
3
2
1
0
10
Pump Speed 1
20
30
Water Flow Rate (L/min)
Pump Speed 2
40
50
200
190
180
170
160
150
140
130
120
110
100
90
80
70
60
50
40
30
20
10
0
7
4
5
6
3
1
0
10
20
2
30
40
50
60
70
Water Flow Rate (L/min)
Pump Speed 3
Pump Speed 4
Pump Speed 5
Pump Speed 6
Max
67
Heating capacity table based on outlet temperature and outside temperature
Heating Capacity Curve
Aquarea Ht. Mono-Bloc Single Phase / Three Phase. Heating Only - MHF
WH-MHF09D3E5
Tamb
HC
IP
COP
HC
IP
COP
HC
LWC
30
30
30
35
35
35
40
-15
9,00
3,50
2,57
9,00
3,75
2,40
8,90
-7
9,00
3,10
2,90
9,00
3,33
2,70
9,00
2
9,00
2,47
3,64
9,00
2,65
3,40
9,00
7
9,00
1,86
4,84
9,00
1,98
4,55
9,00
25
12,00 1,70
7,06
12,00 1,80
6,67
12,00
IP
40
4,05
3,60
2,95
2,25
2,05
COP
40
2,20
2,50
3,05
4,00
5,85
HC
45
8,80
8,90
9,00
9,00
10,80
IP
45
4,30
3,87
3,25
2,50
2,18
COP
45
2,05
2,30
2,77
3,60
4,95
HC
50
8,60
8,90
9,00
9,00
10,60
IP
50
4,65
4,15
3,59
2,80
2,50
COP
50
1,85
2,14
2,51
3,21
4,24
HC
55
8,50
8,90
9,00
9,00
10,20
IP
55
4,95
4,50
3,92
3,16
2,70
COP
55
1,72
1,98
2,30
2,85
3,78
HC
60
8,00
8,90
9,00
9,00
10,00
IP
60
5,10
5,00
4,39
3,50
2,95
COP
60
1,57
1,78
2,05
2,57
3,39
HC
65
7,80
8,90
9,00
9,00
9,80
IP
65
5,90
5,50
4,80
4,00
3,35
COP
65
1,32
1,62
1,88
2,25
2,93
WH-MHF12D6E5
Tamb
LWC
-15
-7
2
7
25
HC
30
12,00
12,00
12,00
12,00
12,00
IP
30
5,20
4,47
3,46
2,56
1,70
COP
30
2,31
2,68
3,47
4,69
7,06
HC
35
12,00
12,00
12,00
12,00
12,00
IP
35
5,57
4,80
3,72
2,73
1,80
COP
35
2,15
2,50
3,23
4,40
6,67
HC
40
11,00
11,50
11,50
12,00
12,00
IP
40
5,55
4,95
3,90
3,10
2,05
COP
40
1,98
2,32
2,95
3,87
5,85
HC
45
10,80
11,20
11,30
12,00
12,00
IP
45
5,53
5,10
4,18
3,48
2,45
COP
45
1,95
2,20
2,70
3,45
4,90
HC
50
10,30
10,80
11,00
12,00
12,00
IP
50
5,67
5,20
4,55
3,85
2,68
COP
50
1,82
2,08
2,42
3,12
4,48
HC
55
9,70
10,10
10,80
12,00
12,00
IP
55
5,80
5,32
4,90
4,32
3,00
COP
55
1,67
1,90
2,20
2,78
4,00
HC
60
9,00
9,85
10,65
12,00
12,00
IP
60
6,05
5,70
5,35
4,90
3,45
COP
60
1,49
1,73
1,99
2,45
3,48
HC
65
8,00
9,60
10,30
12,00
12,00
IP
65
6,15
5,95
5,63
5,45
3,90
COP
65
1,30
1,61
1,83
2,20
3,08
WH-MHF09D3E8
Tamb
LWC
-15
-7
2
7
25
HC
35
9,00
9,00
9,00
9,00
12,00
IP
35
3,50
3,10
2,47
1,86
1,70
COP
35
2,57
2,90
3,64
4,84
7,06
HC
35
9,00
9,00
9,00
9,00
12,00
IP
35
3,75
3,33
2,65
1,98
1,80
COP
35
2,40
2,70
3,40
4,55
6,67
HC
40
8,90
9,00
9,00
9,00
12,00
IP
40
4,05
3,60
2,95
2,25
2,05
COP
40
2,20
2,50
3,05
4,00
5,85
HC
45
8,80
8,90
9,00
9,00
10,80
IP
45
4,30
3,87
3,25
2,50
2,18
COP
45
2,05
2,30
2,77
3,60
4,95
HC
50
8,60
8,90
9,00
9,00
10,60
IP
50
4,65
4,15
3,59
2,80
2,50
COP
50
1,85
2,14
2,51
3,21
4,24
HC
55
8,50
8,90
9,00
9,00
10,20
IP
55
4,95
4,50
3,92
3,16
2,70
COP
55
1,72
1,98
2,30
2,85
3,78
HC
60
8,00
8,90
9,00
9,00
10,00
IP
60
5,10
5,00
4,39
3,50
2,95
COP
60
1,57
1,78
2,05
2,57
3,39
HC
65
7,80
8,90
9,00
9,00
9,80
IP
65
5,90
5,50
4,80
4,00
3,35
COP
65
1,32
1,62
1,88
2,25
2,93
WH-MHF12D9E8
Tamb
LWC
-15
-7
2
7
25
HC
35
12,00
12,00
12,00
12,00
12,00
IP
35
5,20
4,47
3,46
2,56
1,70
COP
35
2,31
2,68
3,47
4,69
7,06
HC
35
12,00
12,00
12,00
12,00
12,00
IP
35
5,57
4,80
3,72
2,73
1,80
COP
35
2,15
2,50
3,23
4,40
6,67
HC
40
11,00
11,50
11,50
12,00
12,00
IP
40
5,55
4,95
3,90
3,10
2,05
COP
40
1,98
2,32
2,95
3,87
5,85
HC
45
10,80
11,20
11,30
12,00
12,00
IP
45
5,53
5,10
4,18
3,48
2,45
COP
45
1,95
2,20
2,70
3,45
4,90
HC
50
10,30
10,80
11,00
12,00
12,00
IP
50
5,67
5,20
4,55
3,85
2,68
COP
50
1,82
2,08
2,42
3,12
4,48
HC
55
9,70
10,10
10,80
12,00
12,00
IP
55
5,80
5,32
4,90
4,32
3,00
COP
55
1,67
1,90
2,20
2,78
4,00
HC
60
9,00
9,85
10,65
12,00
12,00
IP
60
6,05
5,70
5,35
4,90
3,45
COP
60
1,49
1,73
1,99
2,45
3,48
HC
65
8,00
9,60
10,30
12,00
12,00
IP
65
6,15
5,95
5,63
5,45
3,90
COP
65
1,30
1,61
1,83
2,20
3,08
Tamb: Ambient Temperature (°C). LWC: Leaving Water Condenser Temperature (°C). HC: Heating capacity (kW). IP: Power Input (kW)
This data is measured by Panasonic in accordance with EN14511-2 standard. This data is for reference purpose only, and does not guarantee the performance.
Hydraulic Pump Performance
WH-MHF09D3E5 // WH-MHF12D6E5 // WH-MHF09D3E8 // WH-MHF12D9E8
90
External Static Pressure (kPa)
80
70
60
50
40
30
20
10
0
0
10
20
30
40
Water Flow Rate (L/min)
Pump Speed (I)
68
Pump Speed (II)
Pump Speed (III)
50
60
70
AQUAREA
Error Codes
The operation led blinks and an error code appears on the
control panel display.
· Turn the unit off and inform the authorised
dealer of the error code.
· The timer operation is cancelled when an
error code occurs.
Force Heater mode button
· The backup heater also serves as backup in case of malfunctioning
of the outdoor unit.
· Press
to stop the force heater operation.
· During Force Heater mode, all other operations are not allowed.
Error Code List
Diagnosis display
H00
H12
Abnormality / Protection control
No abnormality detected
Indoor/Outdoor capacity unmatched
Abnormality Judgement
—
90s after power supply
H15
H23
H38
H42
Outdoor compressor temperature sensor abnormality
Indoor refrigerant liquid temperature sensor abnormality
Indoor/Outdoor mismatch
Compressor low pressure abnormality
Continue for 5 sec.
Continue for 5 sec.
—
—
H62
H64
H70
H72
H76
H90
Water flow switch abnormality
Refrigerant high pressure abnormality
Back-up heater OLP abnormality
Tank sensor abnormal
Indoor - control panel communication abnormality
Indoor / outdoor abnormal communication
Continue for 1 min.
Continue for 5 sec.
Continue for 60 sec.
Continue for 5 sec.
—
> 1 min after starting operation
H91
H95
H98
Tank heater OLP abnormality
Indoor/Outdoor wrong connection
Outdoor high pressure overload protection
Continue for 60 sec.
—
—
H99
Indoor heat exchanger freeze prevention
—
F12
F14
F15
Pressure switch activate
Outdoor compressor abnormal revolution
Outdoor fan motor lock abnormality
4 times occurrence within 20 minutes
4 times occurrence within 20 minutes
2 times occurrence within 30 minutes
F16
Total running current protection
3 times occurrence within 20 minutes
F20
Outdoor compressor overheating protection
4 times occurrence within 30 minutes
F22
IPM (power transistor) overheating protection
3 times occurrence within 30 minutes
F23
Outdoor Direct Current (DC) peak detection
7 times occurrence continuously
F24
Refrigeration cycle abnormality
2 times occurrence within 20 minutes
F25
Cooling / Heating cycle changeover abnormality
4 times occurrence within 30 minutes
F27
F36
F37
F40
F41
F42
F43
F45
F46
Pressure switch abnormality
Outdoor air temperature sensor abnormality
Indoor water inlet temperature sensor abnormality
Outdoor discharge pipe temperature sensor abnormality
PFC control
Outdoor heat exchanger temperature sensor abnormality
Outdoor defrost sensor abnormality
Indoor water outlet temperature sensor abnormality
Outdoor Current Transformer open circuit
Continue for 1 min.
Continue for 5 sec.
Continue for 5 sec.
Continue for 5 sec.
4 times occurrence within 10 minutes
Continue for 5 sec.
Continue for 5 sec.
Continue for 5 sec.
—
F95
Cooling high pressure overload protection
—
F48
F49
Outdoor EVA outlet temperature sensor abnormality
Out bypass outlet temperature sensor abnormality
Continue for 5 sec.
Continue for 5 sec.
Primary location to verify
—
· Indoor/outdoor connection wire
· Indoor/outdoor PCB
· Specification and combination table in catalogue
· Compressor temperature sensor (defective or disconnected)
· Refrigerant liquid temperature sensor (defective or disconnected)
· Indoor/Outdoor PCB
· Outdoor pipe temperature sensor
· Clogged expansion valve or strainer
· Insufficient refrigerant
· Outdoor PCB
· Compressor
· Water flow switch
· Outdoor high pressure sensor (defective or disconnected)
· Back-up heater OLP (Disconnection or activated)
· Tank sensor
· Indoor - control panel (defective or disconnected)
· Internal / external cable connections
· Indoor / Outdoor PCB
· Tank heater OLP (Disconnection or activated)
· Indoor/Outdoor supply voltage
· Outdoor high pressure sensor
· Water pump or water leakage
· Clogged expansion valve or strainer
· Excess refrigerant
· Outdoor PCB
· Indoor heat exchanger
· Refrigerant shortage
· Pressure switch
· Outdoor compressor
· Outdoor PCB
· Outdoor fan motor
· Excess refrigerant
· Outdoor PCB
· Compressor tank temperature sensor
· Clogged expansion valve or strainer
· Insufficient refrigerant
· Outdoor PCB
· Compressor
· Improper heat exchange
· IPM (Power transistor)
· Outdoor PCB
· Compressor
· Insufficient refrigerant
· Outdoor PCB
· Compressor low compression
· 4-way valve
· V-coil
· Pressure switch
· Outdoor air temperature sensor (defective or disconnected)
· Water inlet temperature sensor (defective or disconnected)
· Outdoor discharge pipe temperature sensor (defective or disconnected)
· Voltage at PFC
· Outdoor heat exchanger temperature sensor (defective or disconnected)
· Outdoor defrost sensor (defective or disconnected)
· Water outlet temperature sensor (defective or disconnected)
· Insufficient refrigerant
· Outdoor PCB
· Compressor low
· Outdoor high pressure sensor
· Water pump or water leakage
· Clogged expansion valve or strainer
· Excess refrigerant
· Outdoor PCB
· Outdoor EVA outlet temperature sensor (detective or disconnected)
· Outdoor bypass outlet temperature sensor (detective or diconnected)
69
Dimensions
Hydraulic Module for all models
502
353
271
205,5
98,5
97,5
97,5
228,5
241
892
38
Bi-Bloc 3 and 5kW
One fan outdoor unit
Two fans outdoor unit
900
900
320
620
140
620
140
320
355
400
320
355
400
140
24
140
24
1340
795
320
70
AQUAREA
Mono-Bloc 6 and 9kW
1283
320
175
275
220
187
154
865
795
39
110
83,5
135
150
980
185
400
355,5
320
160
150
Mono-Bloc 9 to 16kW
1283
320
110
175
275
220
187
154
1410
1340
39
83,5
400
320
355,5
135
160
185
150
980
150
71
Do not add or replace refrigerant other than the specified
type. Manufacturer is not responsible for the damage and
deterioration in safety due to usage of the other refrigerant.
To find out how Panasonic cares for you,
log on to: www.aircon.panasonic.eu
Panasonic Marketing Europe GmbH
Panasonic Air Conditioning
Hagenauer Strasse 43, 65203 Wiesbaden, Germany
Due to the ongoing innovation of our products, the specifications of this catalogue are valid barring typographic errors, and may be subject to minor modifications by the manufacturer
without prior warning in order to improve the product. The total or partial reproduction of this catalogue is prohibited without the express authorisation of Panasonic UK Ltd.
www.eggeassociats.net
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement