NEW AQUAREA RANGE HIGH-EFFICIENCY HEAT PUMP TECHNOLOGY 2014 - 2015 NEW AQUAREA AIR TO WATER HEAT PUMP 2014 - 2015 NEW 2014 / 2015 AQUAREA AIR TO WATER HEAT PUMP Summary HISTORY OF AIR CONDITIONING GROUP ........................................................................................................................6 PANASONIC – LEADING THE WAY IN HEATING & COOLING .............................................................................................7 100% PANASONIC: WE CONTROL THE PROCESS ............................................................................................................7 RELIABILITY FACTS:RELIABLE COMFORT COMES FROM RELIABLE TECHNOLOGIES ...........................................................8 PANASONIC EUROPE ANNOUNCES SUSTAINABILITY DECLARATION ................................................................................10 EXEMPLARY SUSTAINABLE PROJECTS .........................................................................................................................11 PRO CLUB: THE PROFESSIONAL WEBSITE OF PANASONIC ............................................................................................12 AQUAREA DESIGNER ..................................................................................................................................................14 NEW AQUAREA AIR TO WATER HEAT PUMP ..................................................................................................................15 AQUAREA THE BEST SEASONAL EFFICIENCY ................................................................................................................16 PANASONIC HAS DESIGNED A COMPLETELY NEW LINE-UP TO OFFER THE BEST TO OUR CUSTOMERS .............................18 THREE AQUAREA SOLUTIONS ......................................................................................................................................19 NEW HIGH PERFORMANCE FOR LOW CONSUMPTION HOMES. ......................................................................................20 NEW HIGH PERFORMANCE HELPS YOU TO MEET STRICT BUILDING REQUIREMENTS AND REDUCE BUILDING COSTS ........20 NEW T-CAP FOR EXTREMELY LOW TEMPERATURES. INSTALL A CLASS PUMP: INDUSTRY TOP CLASS ENERGY-SAVING! ...22 AQUAREA HT IDEAL FOR RETROFIT: GREEN ENERGY SOURCE WORKS WITH EXISTING RADIATORS ..................................24 PANASONIC AQUAREA HT IS SUPER EFFICIENT EVEN AT LOW TEMPERATURE ................................................................25 AQUAREA COMMERCIAL SOLUTIONS FOR BEST SAVINGS .............................................................................................26 BY FLEXIBLE WITH YOUR WATER SYSTEM ....................................................................................................................27 NEW ALL IN ONE ........................................................................................................................................................28 NEW REMOTE CONTROL. NEW FEATURES ....................................................................................................................30 NEW INDOOR UNIT DESIGN ........................................................................................................................................31 HEAT AND PRODUCE DOMESTIC HOT WATER FOR FREE ................................................................................................32 CONTROL & CONNECTIVITY.........................................................................................................................................34 CONTROL YOUR HEAT PUMP FROM WHEREVER YOU ARE ..............................................................................................36 CONNECTIVITY: GREAT FLEXIBILITY FOR INTEGRATION INTO YOUR KNX / ZIG BEE / MODBUS PROJECTS ..........................37 AQUAREA LINE-UP! ....................................................................................................................................................38 AQUAREA ALL IN ONE HIGH PERFORMANCE BI-BLOC SINGLE PHASE HEATING AND COOLING .........................................40 AQUAREA ALL IN ONE T-CAP BI-BLOC SINGLE PHASE / THREE PHASE HEATING AND COOLING .......................................41 AQUAREA HIGH PERFORMANCE BI-BLOC SINGLE PHASE HEATING ONLY - SDF / HEATING AND COOLING - SDC 3 AND 5KW ...................................................................................................................42 AQUAREA HIGH PERFORMANCE BI-BLOC SINGLE PHASE / THREE PHASE HEATING AND COOLING - SDC .........................43 AQUAREA T-CAP BI-BLOC SINGLE PHASE / THREE PHASE HEATING AND COOLING - SXC ................................................44 AQUAREA HT BI-BLOC SINGLE PHASE / THREE PHASE HEATING ONLY - SHF ..................................................................45 AQUAREA HIGH PERFORMANCE MONO-BLOC SINGLE PHASE HEATING ONLY - MDF / HEATING AND COOLING - MDC .......46 AQUAREA HIGH PERFORMANCE MONO-BLOC SINGLE PHASE / THREE PHASE HEATING AND COOLING - MDC ..................47 AQUAREA T-CAP MONO-BLOC SINGLE PHASE / THREE PHASE HEATING AND COOLING - MXC .........................................48 AQUAREA HT MONO-BLOC SINGLE PHASE / THREE PHASE HEATING ONLY - MHF ...........................................................49 AQUAREA AIR RADIATORS...........................................................................................................................................50 ACCESSORIES ............................................................................................................................................................52 EXAMPLES OF INSTALLATIONS WITH AQUAREA MANAGER ............................................................................................54 A TYPICAL EXAMPLE OF SAVINGS AND EFFICIENCIES THAT AQUAREA CAN OFFER TO YOU ..............................................56 HEATING CAPACITY TABLE BASED ON OUTLET TEMPERATURE AND OUTSIDE TEMPERATURE ...........................................58 ERROR CODES ...........................................................................................................................................................67 DIMENSIONS .............................................................................................................................................................68 Quality Management System Certificate Environmental Management System Certificate Certified to ISO 9001: 2008 Certified to ISO 14001: 2004 Panasonic Appliances Air-Conditioning Malaysia. Sdn.Bhd. Cert. No.: MY-AR 1010 Panasonic Appliances Air-Conditioning Malaysia Sdn.Bhd. Cert. No.: MY-ER0112 Certified to ISO 9001: 2008 Certified to ISO 14001: 2004 Panasonic Appliances Air-Conditioning (GuangZhou) Co., Ltd. Registration Number: 01209Q20645R5L Panasonic Appliances Air-Conditioning (GuangZhou) Co., Ltd. Registration Number: 02110E10562R4L NEW A class pump New All in One solution from 3 to 16kW with 200l tank, A class pump and small foot print. Ideal for new and retrofit homes. PG 32 NEW 5.08 COP high efficiency AQUAREA HIGH PERFORMANCE New 5kW Monobloc, the most efficient solution of the market with a COP of 5.08! Ideal for low consumption homes. PG 22 NEW 100% capacity at -15 ºC AQUAREA T-CAP New 16kW T-Cap Bi-Bloc, ideal for retrofit and commercial applications. PG 26 NEW 100% capacity at -15 ºC AQUAREA T-CAP New 9 and 12kW T-Cap Bi-Bloc, with A class pump, higher efficiency, and energy consumption. PG 26 NEW New remote control to improve performance, comfort and to deliver maximum energy savings. PG 34 NEW New, square-chassis hot water tank, with integral 80-litre buffer tank. PG 60 3 As we move towards our Centenary in 2018, our new brand slogan encapsulates Panasonic’s vision of expanding and pursuing a better life for each of our customers. Working with our many partners, we operate in a wide range of fields such as the home, community, business, travel, realising a better world globally through its contribution to the environment and other activities, in both its B2C and B2B businesses. 4 EDITORIAL 5 History of Air Conditioning Group Panasonic starts with a desire to create things of value. As hard work and dedication results in one innovative product after another, the fledgling company takes its first steps towards becoming the electronics giant of today. 1936 First electric Fan with Automatic Oscillation (36 cm table top model). 6 1958 First room air conditioner launched for domestic installation. Prior to this date, air conditioners were large and only for commercial use. Panasonic developed the first compact air conditioner for windows; it was lightweight and easy to install, improving the quality of life in Japanese homes. 1,100 units were sold in Japan in the first year, and just two years later, in 1960, this figure rose to 230,000. 1973 Panasonic launches the first highly efficient air-to-water heat pump in Japan. 1975 Panasonic becomes the first Japanese air conditioner manufacturer in Europe. 2008 Etherea new concept of air conditioning systems: high efficiency and high performances with a great design. Etherea also includes a very innovative air quality sensor and air purifier in order to enjoy healthy air at home at all times. 2010 New Aquarea. Panasonic has created Aquarea, an innovative new, low-energy system, designed to help you enjoy ideal temperatures and hot water in your home, even with extreme outdoor temperatures. Aquarea cools or heats to ensure maximum comfort. Aquarea is far cleaner, safer, cheaper and environmentally friendly than alternatives using gas, oil and other electrical systems. 2011 New Eco i VRF solution. The new Panasonic VRF solution for big buildings is the most efficient in the industry in more than 74% of combinations. ECO i satisfies the most demanding standards required by design offices, architects, owners and installers. 2012 New GHP units. Pansonic’s gasdriven VRF systems are ideal for projects where power restrictions apply. In 2012, Panasonic extends the Gas Heat Pump range with a new GHP line-up, new GHP G Power (electricity production) and the new Chiller Units. 2013 New ECOi 3-pipes. The best efficiency for your building. Our New 6 Series 3-pipes is achieving a COP of 4.77 at full load, and even more when recovering heat from the building. There is no doubt, Panasonic is reducing environmental impact! 2014 New Aquarea 16kW T-CAP. Improvements deliver impressive, high efficiencies at low ambient temperatures. T-CAP stands for Total Capacity and is capable of maintaining the same nominal capacity even at -15°C without the help of an electric booster heater. Ideal for retrofit and commercial applications. EDITORIAL 100% ANASONIC N 100% P PRODUCTIO UALIT Y ASSURANCE SIGN ND Q TESTING A ELOPMENT AND DE V E D & H C RESEAR ROVIDER SERVICE P Panasonic – leading the way in Heating & Cooling With more than 30 years of experience, selling to more than 120 countries around the world, Panasonic is unquestionably one of the leaders in the heating and cooling sector. With a diverse network of production and R&D facilities, Panasonic delivers innovative products incorporating cutting-edge technologies that set the standard for air conditioners worldwide. Expanding globally, Panasonic provides superior international products transcending borders. 100% Panasonic: we control the process The company is also a world leader in innovation as it has filed more than 91,539 patents to improve its customers’ lives. Moreover, Panasonic is determined to remain at the forefront of its market. In all, the company has produced more than 200 million compressors and its products are manufactured in 294 plants which are located all over the world. You can be assured of the extremely high quality of Panasonic’s heat pumps. This wish to excel has made Panasonic the international leader in heating and turn-key air conditioning solutions for homes, medium-sized buildings such as offices and restaurants, and large-scale buildings. These offer maximum effectiveness, comply with the strictest environmental standards and meet the most avant-garde construction requirements of our time. At Panasonic we know what a great responsibility it is to install heating and cooling systems. Because offering you the best solutions in heating and cooling matters 7 RELIABILITY FACTS Reliable comfort comes from reliable technologies Today, Panasonic air conditioners have earned widespread acclaim throughout the world. A rugged design ensures that the air conditioner will continue to keep the room comfortable, and operate troublefree for many years. Panasonic believes this is the true value of an air conditioner. And this is why we subject them to a wide range of stringent tests. Durability. Long Time Continuous Operation Simulation. Long-term Durability Test The air conditioner’s main mission is to provide a level of durability that allows it to operate stably for years. In order to achieve this, we conduct an accelerated test for 10,000 hours of continuous operation. The results of this test, which is conducted under conditions that are much more severe than actual operating conditions, prove the rugged strength of Panasonic air conditioners. Compressor Disassembly Test After a test with 10,000 hours of continuous operation, we remove the compressor from a randomly selected outdoor unit, disassemble it, then examine the internal mechanisms and parts for possible failure. Panasonic air conditioners continue to provide their designed performance for many years even after prolonged operation under harsh conditions. Operating Test in Harsh Conditions In addition to normal operating conditions, an operating durability test is conducted in a high-temperature, high humidity test chamber at a temperature of 55 °C. For use in cold climates, the test is also conducted in a low temperature test chamber at -20 °C. This test assures that the oil inside the compressor will not freeze during use and interrupt operation. Checking the oil inside the compressor under extremely cold conditions. 8 Waterproof Test The outdoor unit, which is subject to rain and wind, is provided with IPX4 waterproof compliance. Contact sections on printed circuit boards are also resin-potted to prevent adverse effects caused by an unlikely exposure to droplets of water. A resin-potted circuit board. EDITORIAL No Breaking. When Dropped onto Sides or Corners. Shock Resistance Panasonic simulates impacts, vibrations and other environmental conditions that air conditioners might be subjected to during transport. We promise that the quality and performance at the time of the final product inspection are unchanged when the product reaches the user’s home. Drop Test Even with the large impacts that may occur due to improper handling during transportation, the product packaging has been strengthened to prevent it from being damaged. In addition to conventional vertical dropping, more severe conditions in which the sides or corners hit the floor first are carefully tested to ensure that the product’s rigidity and shock-absorbing materials work to prevent problems. Vibration Test Preventing damage that would hinder the product’s performance due to vibration during transport is a major role of the packaging. Panasonic confirms that the product operates properly even after applying vibrations in both horizontal and vertical directions. Warehouse Storage Test During distribution, products may be subjected to extended warehouse storage under unfavourable conditions. To simulate these conditions, we place a weight equal to a stack of five product packages on top of the test package, and leave it in that condition in a room at a temperature of 27°C and a humidity level of 85%. Then, the product is checked for proper operation. Silence. That Does Not Disturb You. Comfort Air conditioners should keep each person in the room comfortable without making their presence known. They should work totally in the background, using their strength to create and maintain a relaxing environment. We build this hidden strength into our air conditioners, and test them repeatedly from this viewpoint. Noise Test The operating noise of the indoor and outdoor units is measured in an echo-free chamber. The noise test verifies that the operating noise is low enough so that the product operation will not disturb daily activities including conversations and sleep. Sunshine simulation. Amenity Test An actual air conditioner is operated in a test room that simulates an ordinary living room. Conditions such as the amount of sunlight entering the room from outside are changed while measuring a variety of parameters, such as cooling speed, cooling efficiency, and temperature and humidity differences throughout the room. This makes it possible to confirm whether the air conditioner is operating at its designed performance level under ordinary conditions. EMC (Electromagnetic Compatibility) Test This test determines whether electromagnetic waves emitted during operation are sufficiently low to prevent adverse effects, i.e., electrical noise, on signals such as TV and radio broadcasts. Remote Control Dropping Test Because the remote control is the main interface between people and the air conditioner, it is naturally subjected to frequent impacts such as drops and bumps - when it is passed from person to person during normal operation. Panasonic drops the remote control from a height of 1.5 metres at various angles to ensure that no problems in basic performance will result from accidental dropping. Quality. Is at the Core of All Our Manufacturing. World Standard Quality Over the years, Panasonic air conditioners have continued to offer the highest possible quality with the lowest environmental impact worldwide. Naturally, the fundamental production principles that are common to all Panasonic products apply to air conditioners as well. The fact that these principles actively support every product, rather than simply serving as slogans, is the result of the endless repetition of challenges and trial-and-error efforts that are conducted at our production bases all over the world. Reliable Parts with Major Standards Approval Panasonic air conditioners comply with all of the major standards that maintain high reliability in the countries and regions where they are marketed. To ensure this, we conduct a variety of tests to examine the quality of materials used in parts. The strength of the resin material used in the propeller fan is confirmed by the tension test. RoHS/REACH Compliant Parts All parts and materials comply with RoHS/REACH, Europe’s worldleading environmental regulations. Stringent inspections of more than 100 materials are conducted to ensure that no hazardous substances are included during parts development. Sophisticated Production Process The air conditioner production line uses advanced, state-of-the-art factory automation technologies to produce products with higher reliability. Products are efficiently manufactured with high and uniform quality. Eco Activities Panasonic has set up eco ideas factories around the globe. While developing and manufacturing energy-saving products based on original environmental technologies, these factories reduce CO2 emissions from manufacturing processes and conduct regional-based environmental communication activities to contribute to both the global environment and the local communities that they serve. 9 Panasonic Europe announces Sustainability Declaration Panasonic establishes new targets for the business’ environmental performance and CSR initiatives Best Global Green Brand 2013 We were recently awarded Interbrand’s 4th Best Global Green Brand 2013 – the highest of any consumer electronics brands. This is the result of our commitment to energy efficient products, reduction in CO2 emissions, kids school ‘eco learning’ programme and much more. Sustainability Declaration. Berlin, Germany, 4th September 2013 Panasonic Europe announces today its new Sustainability Declaration for Europe and CIS, extending its current initiatives to ensure all business activities lead to a more sustainable society. The Sustainability Declaration unites Panasonic’s new brand direction towards ‘A Better Life, A Better World’ with a series of environment and CSR initiatives contributing to the progress and development of society. Recognising the impact on the environment and society through its products and practices, Panasonic aims to deliver on specified targets by March 2016. The European Sustainability Declaration is in accordance with Panasonic’s Global Sustainability Policy, which has been rolled out globally in recent weeks. We aim to realize a lifestyle with virtually zero CO2 emissions throughout the entire home Solar Power Generator HIT solar cells achieve maximum output even on smaller roofs. These solar modules are 100% emission free, have no moving parts and produce no noise. Home AV Panasonic offers a wide range of energy saving home equipment to fulfil a sustainable and comfortable lifestyle. Heat Pump The Aquarea Heat Pump is part of a new generation of heating systems that use a renewable, free energy source: air, to heat or cool the home and to produce hot water. Fuel Cell The Panasonic Fuel Cell is an energy-creating device, which generates electricity and heat at the same time with chemical reaction between hydrogen extracted from natural gas and oxygen. Solar Power Generator Our mobility space can be connected to our HIT solar panels – with help of our storage batteries. LED Lamps Expertise gathered over years of research and development has enabled Panasonic to provide a renaissance in energysaving home LED lighting – with our LED Nostalgic Clear lamp. Home Appliances Panasonic is globally committed to develop products which are environmentally friendly. Panasonic delivers home appliances such as refrigerators and washing machines that incorporate the latest energy-efficient technology. 10 Storage Battery The battery stores the energy generated by a combination of solar power and fuel cells to ensure a constant supply of electricity on demand. EDITORIAL Exemplary sustainable projects Fujisawa Sustainable Smart Town Homes will employ the full range of Panasonic’s most advanced systems for energy production, storage and management. In this project, a new concept and process will be adopted to build the town by designing spaces first with a primary focus on services based on people’s lifestyles and creating an optimal smart infrastructure. In Fujisawa SST, Panasonic will offer its unique solutions from an Eco & Smart perspective. With bringing energy to life for residents as the town concept, we will provide services that enhance people’s lives with photovoltaic power, security, mobility, community, and healthcare. The unparalleled town building, where as many as 1,000 families will live, will serve as a new business model both within Japan and overseas. Panasonic will provide the project with a variety of its energy efficient heating and cooling products, including the Aquarea Air Source Heat Pump – a super-efficient system for providing heating and / or cooling facilities, as well as the production of domestic hot water. These heat Panasonic joins Smart Electric Lyon pumps are especially equipped with connectivity consortium solutions from Panasonic to ensure the systems What is Smart Electric Lyon? are easy to use, and collect the vital, accurate Smart Electric Lyon is a project that looks at data. The company will also integrate other home electricity consumption as a key part of the building energy solutions of tomorrow. The project equipment solutions such as LED white lighting products to optimize the overall energy aims to develop a wide range of innovative management of the project’s properties. facilities and services through real-life This project is particularly apt for Panasonic, as experiments to test energy saving technologies heating and hot water occupy a prominent place and to measure how consumers can control in household energy consumption. Panasonic energy consumption. plans to make its European and French resources This experiment, unprecedented in scale in Europe, will be conducted for four years in more available for Smart Electric Lyon. The company than 25,000 homes, businesses and communities has involved for the project a dedicated and experienced R&D team from Panasonic’s European of Grand Lyon. It is intended to test innovative technical centre in Frankfurt. solutions that will consume less and better. The connected home of the future 11 PRO Club: the professional website of Panasonic Panasonic has an impressive range of support services for designers, specifiers, engineers and distributors working in the heating and cooling markets. Panasonic announces a new initiative for all professionals involved in the heating and cooling business - the Panasonic PRO Club (www.panasonicproclub.com). Panasonic PRO Club is the online tool which makes your life easier! You just have to register and a lot of functionalities are freely available to you, where ever you are, from your computer or smart phone! · Print catalogues with your logo and your address · Download the latest Aquarea designer to define your system and select the good Aquarea Heat pump. · Calculate the specs of the Aquarea Air fan coil based on the parameters of your system · Get Documents of conformity and all other documents you may need · Download all the service manuals, end user manuals and installation manuals · Know what to do with error codes · Find out about the latest news first · Register for training and take part in online training www.panasonicproclub.com or connect simply with your smartphone to the proclub using this QR: 12 Highlighted Features · Extensive library of resources · Tools & Apps for end users. Check availability in your country: - My Home: sizing wizard for domestic and A2W range - My Project: Contact form to Panasonic team - iFinder: Lists of installers displayed by postcode · Special offers & promotions · Training PRO Academy · Catalogues (Commercial documentation) · Marketing (Images in high resolution, advertisements, deco guidelines) · Tools (Professional software, sizing tools...) NEW Highlighted Features · NEW! Installers customize leaflets in PDF format with their logo & contact details · NEW! Energy label generator. Download energy labels of any device in PDF format · NEW! Heating calculator demand · NEW! Noise calculator for outdoor unit · NEW! Aquarea Radiator calculator · NEW! Error Code Search by error code or unit ref. Compatible with smartphone and tablet computer · NEW! Revit / CAD Images / Spec texts · NEW! Access to Pananet, online library of technical documentation · NEW! Download Documents of Conformity and other Certifications · NEW! Commissioning online EDITORIAL NEW! Easy download Panasonic service documentation and brochures Panasonic PRO Club is fully compatible with Tablet computer and smartphone NEW! Customize leaflets with your logo & contact details. Save and print the PDF NEW! Energy label generator. Download Energy labels of any device in PDF format NEW! Error Code on your smartphone and your PC: Search by error code or model reference. Online version + downloadable version for offline use The Panasonic PRO Academy opens its doors Panasonic takes its responsibility to its distributors, specifiers and installers seriously and has developed a comprehensive Training Programme. The Panasonic Pro-Academy encompasses the traditional hands-on approach, as well as embracing today’s technology to offer an eLearning facility available 24 hours, 7 days a week! New training courses cover three levels. Design, installation, and commissioning & trouble-shooting. Training courses include: · Domestic applications Air to Air · Aquarea air source heat pumps · VRF ECOi The courses are offered on site at Panasonic’s premises across Europe as well as via the Panasonic ProClub eLearning site. The Training Centres display Panasonic’s latest product range and give delegates an opportunity to get hands-on experience with the latest controllers, indoor and outdoor units from the VRF ECOi, Etherea, GHP and Aquarea ranges. 13 Aquarea Designer Panasonic provides bespoke software helping system designers, installers and dealers to very quickly design and size systems, create wiring diagrams and issue bills of quantities at the push of a button. This program allows HVAC designers, installers and distributors to identify the correct heat pump for a particular application from Panasonic’s Aquarea range, calculate the savings compared to other heat sources and very quickly calculate CO2 emissions. Using Panasonic’s Aquarea Designer, projects can be developed simply and easily, by either using the Quick Design or Expert Design options. Each allows the user to build up the project data in a simple step-by-step process and choose to output reports (in either Quick or Large formats) as HTML files or as print-outs. To create these useful reports, project data is input, including: · Heated area · Heating requirement · Heating flow and return temperatures · Climate data (from a simple drop-down menu) including outdoor temperature · Type of hot water tank, storage capacity and hot water target temperature. 14 AQUAREA Aquarea Designer also means saving Aquarea Designer will calculate the project’s energy costs in terms of hot water, heating and pumping. It will show the equipment running times and calculate the COP (coefficient of performance). It then allows the designer to show clients a comparison with other equipment options such as heating by conventional gas-fired boilers, oil systems, wood, standard electric heating and electric night storage heaters. This compares running costs, initial investment costs and maintenance costs. The comparison can also be made for CO2 emissions and savings. PRO Club: the professional website of Panasonic Panasonic announces a new initiative for all professionals involved in the heating and cooling business - the Panasonic PRO Club (www.panasonicproclub.com). This exciting new portal provides distributors, installers, engineers and specifiers with a direct communication channel with one of the industry’s major manufacturers. The website contains a wealth of information from the latest versions of Panasonic’s Aquarea and Etherea Design Software, to Technical Documentation, Catalogues and Images for the company’s wide range of heating and cooling systems - all in an easy to navigate and use website. Also, registered users will be able to access news regarding special promotions and take advantage of these offers, as well as access helpful business advice such as ideas and guidelines for showroom decoration or van livery featuring Panasonic logos and display material. Donwload on www.panasonicproclub.com or connect simply with your smartphone to the proclub using this QR: 15 Inverter+ System. The A Inverter+ system provides energy savings of up to 30% compared to non Inverter models. Both you, and nature, wins! High efficiency heating Environmentally friendly refrigerant R410A / R407C Down to -20 ºC in heating mode OUTDOOR TEMPERATURE Up to -20°C In Heating Mode. The Heat Pumps works in heat pump mode with an outdoor temperature as low as -20°C. Renovation. Our Aquarea heat pumps can be connected to an existing or new boiler for optimum comfort even at very low outdoor temperatures. Boiler connection RETROFIT Solar Kit. For even greater efficiency, our Aquarea heat pumps can be connected to photovoltaic solar panels with an optional kit. Solar panels connection SOLAR KIT DHW With Aquarea you can also heat your domestic hot water at a very low cost with the optional hot water cylinder. Domestic hot water DHW Connectivity. The communication port is integrated into the indoor unit and provides easy connection to, and control of, your Panasonic heat pump to your home or building management system. Easy control by BMS CONNECTIVITY OP TIO N AL Internet Control Ready Refrigerant R410A / R407C. R410A / R407C offers optimal performance and involves no environmental cost since it does not harm the ozone layer. INTERNET CONTROL 5 year compressor warranty Internet Control is a next generation system providing a user-friendly remote control of air conditioning or heat pump units from everywhere, using a simple Android or iOS smartphone, tablet or PC via internet. Aquarea’s new Air To Water Heat Pump for residential applications Offering capacities from 3kW all the way through to 16kW, the Aquarea Heat Pump Range is the widest on the market, ensuring a system is available, whatever your heating and cooling needs. Suitable for new build and refurbishment projects, the systems are cost-effective and environmentally friendly. 5 Years Warranty. We guarantee the compressors in the entire range for five years. * Not all products certified. As the certification process is on-going and the list of certified products constantly changing, please check for latest details on the official websites. ehpa 16 NEW AQUAREA SEASONAL EFFICIENCY NEW AQUAREA AIR TO WATER HEAT PUMP Panasonic’s new Aquarea Air To Water system can work in outdoor temperature even at -20°C Panasonic’s new Aquarea system, based on high-efficiency heat pump technology, not only heats your home and hot water, but also cools your home in summer with incredible operating performance. This creates perfect comfort whatever the weather conditions, even at outdoor temperatures as low as -20°C. Panasonic new heat pumps are designed in response to the new demand for low consumption housing, with high efficiency and low running costs. 17 SEASONAL EFFICIENCY A class pump Aquarea the best seasonal efficiency Panasonic’s new Aquarea air to water system can work in outdoor temperature even at -20°C Panasonic’s new Aquarea system, based on high-efficiency heat pump technology, not only heats your home and hot water, but also cools your home in summer with incredible operating performance. This creates perfect comfort whatever the weather conditions, even at outdoor temperatures as low as -20°C. Panasonic new heat pumps are designed in response to the new demand for low consumption housing, with high efficiency and low running costs. Impressive Energy Savings Panasonic’s Aquarea Heat Pump provides savings of up to 80% on heating expenses compared to electrical heaters. A class pump 18 The Panasonic Aquarea Heat Pumps are designed and produced by Panasonic and not by other companies. AQUAREA Up to 80% energy savings* “We expect to save around 1,000 € a year on fuel costs and we’ve been able to get rid of a large ugly oil tank in the garden thanks to the new Aquarea.” Aquarea Customer, Surrey¹ At the forefront of energy innovation, Aquarea is resolutely positioned as a “green” heating and air-conditioning system. Aquarea is part of a new generation of heating and air-conditioning systems that use a renewable, free energy source – the air – to heat or cool the home and to produce hot water. The Aquarea heat pump is a much more flexible and cost-effective alternative to a traditional fossil fuel boiler. 1) Information provided by Aquarea customer, August 2012. Air source heat pumps – Quick facts · Provides sustainable heating, cooling and hot water for your home · 30%-40% reduction in annual energy bills · Ideal for properties without access to mains gas · Operates even in freezing temperatures (-20°C). · Externally positioned saving valuable internal living space · Proven technology from Panasonic and already well established in other EU countries Why air source heat pumps? · Reduced heating bills and maintenance costs · Savings of up to Euro 1,000 a year are possible · Reduce your carbon footprint · Simple to integrate into most heating systems · Energy efficient alternative to oil, LPG and electric systems · Highly compatible with other energy efficient energy sources eg solar panels “Green” High-efficiency heating with Panasonic’s new Air to Water Heat Pump Systems Panasonic’s Aquarea Heat Pump provides savings of up to 80% on heating expenses compared to electrical heaters. For example, the Aquarea 5kW system has a COP of 5,08. This is 4,08 more than a conventional electrical heating system which has a maximum COP of 1. This is equivalent to an 80%* saving. Consumption can be further reduced by connecting photovoltaic solar panels to the Aquarea system. GAS BOILER OIL BOILER AQUAREA UP TO 80% ENERGY SAVINGS* ELECTRICAL HEATING 80% 0,803 kW 1kW 0,9kW 1kW 0,9kW 1kW 1kW RENEWABLE ENERGY GAS HEAT OIL HEAT ELECTRICITY HEAT 0,197kW Other heating systems POWER INPUT / ENERGY CONSUMPTION POWER OUTPUT / HEATING CAPACITY (kW) ELECTRICITY OUTDOOR ENERGY 1kW HEAT 20% ELECTRICITY Aquarea * Up to 80% of the heat produced by a heat pump is free, since it comes from the outdoor air. Rating conditions: Heating: Inside air temperature: 20°C Dry Bulb / Outside air temperature: 7°C Dry Bulb / 6°C Wet Bulb. Conditions : Water input temperature: 30°C Water output temperature: 35°C 19 Panasonic has designed a completely new line-up to offer the best to our customers 6 There are several types of heat pump available: · The Mono-Bloc system: This only has an outdoor unit. The installation doesn’t require a refrigerated connection and is only connected to the heating and/or hot water. · The Bi-Bloc system: The system, separate indoor and outdoor units, connects to the heating and/or hot water system. A wide range from 3 to 16kW, Single and Three Phase, Mono-Bloc and Bi-Bloc. 3 Versions: · Aquarea High Performance: From 3 to 16kW · Aquarea T-CAP: From 9 to 16kW · Aquarea HT: From 9 to 12kW 5 2 3 1a 1b Aquarea outdoor Bi-Bloc option 20 4 AQUAREA Three Aquarea solutions A 5.08 COP A class pump high efficiency class pump 1 AQUAREA HIGH PERFORMANCE Aquarea High Performance for low consumption houses. From 3 to 16kW For a house with low temperature radiators or under-floor heating, our high performance Aquarea HP is a good solution. This solution can work as a stand-alone unit or can be combined with an existing gas- or oil-fired heating system depending on requirements. This new solution is ideal for low consumption homes. 1) For WH-MDC05F3E5. 1b 100% Output water 65 ºC capacity at -15 ºC HIGH TEMP HEAT PUMP AQUAREA T-CAP Aquarea T-CAP. From 9 to 16kW If the most important aspect is to maintain nominal heating capacities even at temperatures as low as -7°C or -15°C, select the Aquarea T-CAP. This ensures that there is always enough capacity to heat the house without help from an external boiler – even at extremely low temperatures. Aquarea T-CAP always has high efficiency and high heating capacity even at extremely low temperatures. With Aquarea T-CAP, you can always enjoy high savings. Aquarea HT. From 9 to 12kW For a house with traditional high-temperature radiators (such as cast iron radiators), the Aquarea HT Solution is the most appropriate as the Aquarea HT can work in output water temperatures of 65°C even at outdoor temperatures as low as -20°C. Aquarea HT is able to deliver hot water to 65°C with the Heat Pump alone. 2 3 Optional Optional 1a Aquarea outdoor air source heat pumps Panasonic has developed an extensive range of air-to-water heat pumps designed to efficiently convert free air into sustainable heating and hot water. Fitted externally to your home and designed to operate in all year round weather conditions (-20°C), it’s the smart alternative to oil, LPG and electric heating systems. Aquarea Heat Pump Manager This new generation of smart controllers for eco-efficient heating, features our versatile stand-alone controller not only for our heat pump systems, but also your gas, oil boiler and all other devices installed on your heating system. Heating control App for smart phone, tablet or computer The heating control App allows you to control the heating and hot water system via your smart phone, tablet or computer with ease, whether at home or away. The heat pump can be also connected to house management system using KNX, Modbus or Zig Bee interfaces. 4 5 6 Optional Optional Optional Super High Efficiency: PAW-TE20/30/50E3HI · High efficient tank solution: specially designed to improve the efficiency of the sanitary hot water production. · HI lineup: - low energy losses - high exchange surface for high efficiency and short time to heat up the water High efficient radiators for heating and cooling · High efficient radiators working with water at 35°C. · No need for two kits if both floor heating and radiators are required. · As the product is efficient, it opens the possibility to also provide cooling while still meeting construction requirements. Panasonic offers a cooling mode within its heat pump range for low consumption homes Heat Pump + HIT Photovoltaic solar panel Photovoltaic solar panels: the best solution for big savings. Combining photovoltaic solar panels with your heat pump can help to further reduce your electrical consumption and CO2 emissions. Additionally, with the unique HIT photovoltaic solar panel technology from Panasonic, you can produce more electricity per square metre, helping you to increase your energy savings still further. 21 For new s ation l l a t s n i and low tion p m u s n co homes 5.08 COP high efficiency AQUAREA HIGH PERFORMANCE area 5kW New Aqu -Bloc Mono New High Performance for low consumption homes. Maximum savings, maximum efficiency, minimum CO2 emissions, minimum of space. Panasonic has designed the new Aquarea Bi-Bloc and Mono-Bloc heat pumps for homes which have high performance requirements. Whatever the weather, Aquarea can work even at -20 °C! The New Aquarea is easy to install on new or existing installations, in all types of properties. New High Performance helps you to meet strict building requirements and reduce building costs The heating and production of hot water have a very important impact on the energy consumption of a house. Efficient Panasonic heat pumps can help to significantly reduce the energy consumption of the house. Total energy consumption of a conventional house, compared to the energy consumption with Panasonic heat pumps Total energy consumption of a conventional house¹ Energy consumption with Panasonic heat pumps² Heating 26% 26% 47% 27% 22 38% SAVINGS 24% Sanitary Hot Water Domestic Appliances³ 12% 1. Source: IDEA, European values 2010. Consumption of a conventional house of 80 kWh/(m².year). 2. Source: Panasonic, RT2012 simulation, house of 50 kWh/(m².year) per year, equipped by Panasonic heat pump. 3. Eg. Fridge telephone, oven,… NEW AQUAREA Key points of the line-up · A-Class pump significantly reduces the energy consumption Equivalent to 100 €/year saving* · A Class pump adapts water pressure according to demand, reducing energy consumption, noise on the valves, and makes installation easy. · No Backup heater needed to maintain the capacity at -15°C, high efficiency guaranteed even at -15°C · Many new remote control functions added: Auto mode, holiday mode, show power consumption HIGH PERFORMANCE PUMPS ARE ALSO HIGHLY EFFICIENT COP 75 W Standard pumps 47 W A class pump New A class pump with Constant water flow (Dynamic pump control) for 5kW Mono-Bloc Comparison of energy consumption - Standard pumps vs A class pump * Based on German market: Assuming Standard pump may vary depending on consumption and energy cost. HEATING CAPACITY 6 6 5 5 4 4 3 3 2 2 1 1 0 0 WH-MDC05F3E5 At -15°C* -5 db(A)² 50 city n -15°C 30 20 NORMAL MODE QUIET MODE² 1. Sound pressure measured at 1 m from the outdoor unit and at 1.5 m height. 2. At standard condition working at heating capacity at +7°C (heating water at 35°C) for two fans outdoor units. For one fan outdoor units, night mode reduction is 3dB(A). 5,0kW eede d to h · High flexibility with Panasonic Inverter compressors · High performance even at part load eat t he ho use -7°C +2°C +7°C Outdoor temperature 8,0kW 5,0kW Panasonic heat pump does not need heater as the capacity is maintained Capacity of other heat pumps need to be higher than the Panasonic heat pumps 5kW WH-MDC05F3E5 p t pum r hea Othe Other Heat pumps needs electrical heater to cover the needs of the house 40 * (heating water at 35°C) Capacity is stable even at -15°C, no need to oversize the heat pump Capa Capacity inkW NOISE LEVEL At +7°C* 5kW WH-MDC05F3E5 Special attention has been given to noise levels - Panasonic created a night mode to reduce the noise when it’s needed. db(A)¹ At +2°C* 5,0kW Capacity inkW With a Panasonic heat pump, there is no need to oversize the heat pump to reach the required capacity at low temperatures. · Dedicated software for low consumption houses which allows the heat pump to produce hot water at 20°C. This is needed during the seasons, when a little heating is required · No need for an additional expansion vessel, as the unit already has a 6l expansion vessel · No buffer tank required as the Panasonic heat pump has an inverter compressor which can regulate the capacity. (Please check on the service manual the minimum volume of water needed on the circuit) · 3kW electrical heater is included on the heat pump · Panasonic heat pumps can work in outdoor temperatures as low as -20°C and guarantee the capacity without backup heating down to -15°C · Panasonic heat pumps are very quiet and have a night mode program for even lower noise. See noise calculator on www.panasonicproclub.com WH-MDC05F3E5 At -7°C* -15°C Capa city n eede d to h Bad performance to big capacity 5,0kW · High flexibility with Panasonic Inverter compressors · High performance even at part load eat t he ho -7°C use +2°C +7°C Outdoor temperature 23 AP FOR C T w e N ly low e m e tr x e ures rat e p m te 100% capacity at -15 ºC AQUAREA T-CAP area New Aqu loc B 16kW BI- New T-CAP for extremely low temperatures. Install A Class pump: Industry top class energy-saving! The whole T-CAP line-up can replace old gas or oil boilers, and in a new application with under floor heating, low temperature radiators or even fan-coil heaters. This range can also be connected to a solar kit in order to increase efficiency and minimize the impact on the ecosystem. Finally, it is possible to connect a thermostat for even better heating or cooling control and management. · T-CAP stands for Total Capacity. This line-up is able to maintain the same nominal capacity even at -15°C without the help of an electrical booster heater. · High heating capacity even at low ambient temperatures. · Maintains capacity of 16 kW until -15°C outdoor temperature. Adding many new functions: Auto mode, Holiday mode, power consumption display. The New T-CAP range has extended with the addition of the 16kW pump The new 16kW maintains full capacity of 16kW even at outdoor temperatures down to -15°C. The 16kW fits perfectly to retrofit houses, as well as to commercial applications to heat and cool the applications and also to provide sanitary hot water. 24 NEW AQUAREA New Aquarea T-CAP. High capacity improvement at low ambient & high efficiency Best efficiency compared to other heating Efficiency systems Enhance larger capacity (16kW) More Energy saving with A Class pump. Adding new functions Auto mode, Holiday mode, Displays power consumption, New de-ice control, Concrete Dry mode, Lock cooling mode and Pump speed control. Panasonic heat pumps have a maximum COP of 4.85 at + 7 °C which makes them much more efficient than fossil fuel fired boilers, gas boilers and electrical heaters. 5 Water 35 ºC 4.85 Applications 4 3.07 For commercial applications For heating and cooling mode For heating and sanitary hot water Wide range of capacities now covered - from 9kW to 45kW with the Heat Pump Manager. Also you are able to connect up to five heat pumps on cascade with the Heat Pump Manager. The 16kW model is able to heat the water at 55°C and can work even when the temperature is as low as -20°C. Cooling operation can be activated on the remote control to cool water up to +5°C. Efficient domestic hot water tanks allow large storage for high consumption of hot water (for example Jacuzzi or bathtub). All our tanks have an anti-legionella protection with a backup heater of 3kW. 2 1 0 Fuel fired boiler Aquarea T-CAP maintains the nominal capacity until -15°C The T-CAP line-up is able to maintain the same nominal capacity even at -15°C without the help of an electrical booster heater. T-CAP is also able to provide extremely high efficiencies, whatever the outside or the water temperature. Panasonic has now extended the range with the new three phase 16kW. kW Heating capacity Gas boiler Panasonic T-CAP 9 kW at +7°C Panasonic T-CAP 9 kW at -7°C · Backup heater capacity can be selected (3/6/9kW) · Cooling mode activation possible by software* * This activation can only be done by service partner or installer PANASONIC T-CAP Capacity is stable even at -15°C, no need to oversize the heat pump 16kW 16kW 16kW T-CAP Capacity in kW A Class pump. More Energy saving 2.11 Water 55 ºC Replace easily expensive gas or oil boilers for high efficient 16kW T-CAP or manage bivalent installations (heat pump and existing gas or oil boiler) with the Heat Pump Manager. Further information on: www.panasonicproclub. com 2.85 Water 35 ºC For retrofit houses Water 55 ºC 3 Capa city n 18 · High flexibility with Panasonic Inverter compressors · High performance even at part load eede d to h eat th e hou 16 14 -15°C se -7°C +2°C +7°C Outdoor temperature 12 COMPARISON WITH COMPETITORS 18kW 10 8 16kW Panasonic heat pump does not need heater as the capacity is maintained 4 p t pum r hea Othe Other Heat pumps need electrical heater to cover the demand of the house 2 Bad performance to big capacity 16kW T-CAP Capacity in kW 6 Capacity of other heat pumps need to be higher than the Panasonic heat pumps Capa city n eede d to h 0 +7°C +2°C -7°C eat th -15°C e hou se Outdoor temperature (heating water at 35°C) T-CAP 16kW High connectivity 16kW -15°C -7°C +2°C +7°C Outdoor temperature 25 HT AQUAREA R FO SOLUTION °C 65 RETROFIT Output water 65 ºC HIGH TEMP HEAT PUMP Aquarea HT ideal for retrofit: green energy source works with existing radiators Replace a traditional heating source (such as oil or gas) with Aquarea HT, but keep existing old style radiators for minimum disruption to the home. From 9 to 12kW. For a house with traditional high-temperature radiators (such as cast iron radiators), the Aquarea HT Solution is the most appropriate as the Aquarea HT provides output water temperatures of 65°C even at outdoor temperatures as low as -15°C. Aquarea HT is able to deliver hot water to 65°C with the Heat Pump alone. Panasonic Aquarea HT is super efficient even at low temperature. Heating Capacity of a 9 kW HT (WH-SHF09F3E5) COP Coefficient of Performance kW COP 9 5 8 4 7 6 3 5 4 2 3 2 1 1 0 0 +7°C +2°C -7°C -15°C +7°C Heating capacity of a 9 kW HT Water 35 ºC 26 Water 55 ºC +2°C -7°C -15°C Heating capacity of a 9 kW HT Water 65 ºC Water 35 ºC Water 55 ºC Water 65 ºC AQUAREA Panasonic Aquarea HT is super efficient even at low temperature Aquarea HT: High savings and low CO2 The results of replacing traditional heating systems with Aquarea HT are clear: lowest running cost and lowest CO2 emissions. Panasonic heat pumps are much more efficient than gas boilers and help you to reach your house energy targets easier. Yearly savings with Aquarea HT Euro/Year Running Costs* 2000 1500 Smart Bivalent operation Thanks to Aquarea HPM (Heat Pump Manager), it is possible to combine different heat sources and use the most appropriate source, depending on user’s preferences. This smart control will decide which is the best source to use anytime. Thus, if it is necessary to combine gas heater, oil with heat pump, Aquarea HPM is simply the best solution. Heat Pump + Boiler Management with DHW with PAW-HPM12ZONELCD-U 1000 500 0 Panasonic Heat Pump Oil Gas * For a 170 m² house and 40 W/m² energy losses in central Europe Conditions, outside minimum conditions -10°C. Easy installation Air source heat pumps are simple to install. They do not require a chimney, gas connection nor oil tank. All that is required is a standard power supply connection. Aquarea heat pumps are also quick to start up. New DHW Tank with buffer Tank PAW-TD20B8E3-NDS Designed for retrofit applications, the new DHW 200l tank with a 80l buffer tank is particularly suitable for fast integration on an existing installation. Panasonic has developed a New tank with 80l Buffer tank and 200l Sanitary hot water cylinder. This tank includes a 3-way valve and an A Class pump. Easy to install, nice looking, high efficiency for DHW production and for heating. 27 L OR RETAI F N O I T U SOL TAURANT S E R D N A PACIT Y A C W K 0 8 Aquarea commercial solutions for best savings AREA NEW AQU LOC B 16KW BI- Efficient Panasonic heat pumps can help to significantly reduce the energy consumption of your business. Recent improvements to air source heat pump technology, including compact single unit systems, can provide an ideal housing and commercial solution. They offer space saving, energy-efficient heating and can be easily adapted for installation in flats, houses and commercial premises. And for businesses producing heat, such as restaurants, installing an Aquarea heat pump system can also use this wasted heat to improve energy efficiency further. “Green” High-efficiency heating with Panasonic’s new Air to Water Heat Pump Systems Panasonic’s Aquarea Heat Pump provides savings of up to 80% on heating expenses compared to electrical heaters. For example, the Aquarea 5kW system has a COP of 5,08. This is 4,08 more than a conventional electrical heating system which has a maximum COP of 1. This is equivalent to a 80%* saving. Consumption can be further reduced by connecting photovoltaic solar panels to the Aquarea system. AQUAREA UP TO 80% ENERGY SAVINGS* GAS BOILER OIL BOILER ELECTRICAL HEATING 80% 0,803 kW 1kW 0,9kW 1kW 0,9kW 1kW 1kW RENEWABLE ENERGY GAS HEAT OIL HEAT ELECTRICITY HEAT 0,197kW Other heating systems POWER INPUT / ENERGY CONSUMPTION POWER OUTPUT / HEATING CAPACITY (kW) 28 ELECTRICITY OUTDOOR ENERGY 1kW HEAT 20% ELECTRICITY Aquarea * Up to 80% of the heat produced by a heat pump is free, since it comes from the outdoor air. Rating conditions: Heating: Inside air temperature: 20°C Dry Bulb / Outside air temperature: 7°C Dry Bulb / 6°C Wet Bulb. Conditions : Water input temperature: 30°C Water output temperature: 35°C AQUAREA By flexible with your water system Easy connection to existing system · Fan Coils · Floor Heating · 4 way and 2 way convectors · Domestic hot water tanks Air Curtain Convectors HPM to control the 4 heat pumps on cascade mode* Key points: · High efficiency · Very good part load management · Cascade management for higher durability of the system High Efficiency Aquarea Hidrokit Supermarket with Aquarea Heat pump technology is scalable, meaning that it can be installed in buildings of varying sizes, offering both small- and large-scale heating solutions. The technology is also environmentally friendly when compared to existing technologies, offering demonstrable energy-use and emissions savings and in most cases; will deliver operational cost savings when compared with fossil fuel alternatives. 4 Aquarea T-Cap Heat Pump 16kW on cascade mode Super High Efficiency Tanks From 200L to 500L for domestic hot water Buffer Tank of 1000 l * 1 HPM can control 3 HP, on this case 2 HPM are needed Key points: · Produce hot water efficiency · Fast return of investment · Easy control · Cascade management for higher durability of the system High Efficiency Aquarea Air Radiators 32% more efficient than standard radiators HPM to control the 5 heat pumps on cascade mode* Air Curtain High Efficiency Aquarea Hidrokit Restaurant with Aquarea If you look for savings on you business, Aquarea is the right choice! Ideal for heating, cooling and for production of big quantities of hot water at 65 degres, Aquarea have a extremely quick return on investment and a low CO2 footprint. 5 Aquarea T-Cap Heat Pump 16kW on cascade mode Buffer Tank of 1000 l Super High Efficiency Tanks From 200L to 500L for domestic hot water * 1 HPM can control 3 HP, on this case 2 HPM are needed 29 N ONE I L L A W NE AND COMPACT STALL IN EASY TO 1 New All in one* Highly efficient solution 2 Easy installation 3 A class pump 4 200l Tank included 5 Easy integration of the HPM remote control 10 YEARS OF TY A W RRAN LESS IN A T S THE NK STEEL TA New All in One hydromodule + 200l tank Panasonic has developed a highly efficient solution, easy to install. Furthermore, Panasonic has developed a range of controllers which allows the control of 2 heating zones, bivalent and cascade systems. Line up 3, 5, 7, 9kW with 12, 14, 16 kW Single Phase and 9, 12, 14, 16kW Three Phase. *Preliminary design. Significant changes may occur. Aquarea All in One Bi-Bloc (Inverter) HIGH PERFORMANCE 3kW T-CAP 30 5kW 7kW 9kW 9kW 12kW 12kW 14kW 16kW 16kW AQUAREA High efficiency solution The best of Panasonic: · Best stainless steel tank with high insulation to reduce energy losses · High exchange surface to increase efficiency · Best performing Aquarea hydraulic module to heat the water. Connectivity Possibilities 3 Remote controls can be installed: · New Remote control. New function for customer: - Auto Mode for Heating and Cooling mode - How to show Energy Consumption - How to set Holiday Mode · Heat pump Manager for more then 600 installations possible (as 2 zone control, Bivalent, etc.) · Heat pump Manager with touch screen LCD. All In One Tank+indoor unit WH-ADC0309G3E5 Outdoor unit connection WH-UD03EE5 WH-UD05EE5 WH-UD07FE5 WH-UD09FE5 WH-UD12FE5 WH-UD14FE5 WH-UD16FE5 WH-UX09FE5 WH-UX12FE5 WH-UD09FE8 WH-UD12FE8 WH-UD14FE8 WH-UD16FE8 WH-UX09FE8 WH-UX12FE8 WH-UX16FE8 WH-ADC1216G6E5 WH-ADC0916G9E8 3 Remote controls can be installed* New Remote control External touch Heat Pump display available Manager with HPM (HPM) Pressure relief valve Purge Pressure gauge Expansion vessel 10l Electrical heater A class pump with 7 speeds Electrical box with RCCB 200l tank with high insultation Pipings to the heating system and tank 15cm reserved to install pipings * Preliminary design. Significant changes may occur. Easy installation The pipings are sited on the bottom of the heat pump to make the installation easy and invisible. A 15cm gap under the unit provides space to connect the pipes. To make the installation even easier, a piping kit is available in order to pre mount the guide and fix it on the wall during the construction phase of the house. Pippings Protection to cover the space for a nice integration 7cm separation cover to hide the pipings. Flexible pipes as accessories 1 Flexible piping + Flexible pipes as accessories 2 Wall separation Accessories Flexible piping kit with pre mounted element. PAW-FP-WMP-1: Flexible pipings and wall mounting plate for all in one. 1” for heating x2 5/8” for water x2 Mounting system 31 AQUAREA NEW REM MOTE CONTROL New remote control. New features New Remocon changing point For 2014, Panasonic has introduced a new remote controller to improve performance, enhance comfort and deliver maximum savings. Better user interface: 1. Adding Holiday Mode 2. Adding Power Consumption · Floor heating concrete dry mode · How to Lock Cool Mode · Class A Pump management with 7 speeds Floor heating concrete dry mode: Allows slow increase in temperature of floor heating via software. 3 1 2 4 LCD display: 1. Expand LCD display to show mode on left and right side 2. Adding AUTO mode and remove defrost display (using heat blink) 3. Change not available into EXT SW OFF 4. Adding kWh and Hr New function for installer Temperature 1 6 5 6 Button: 5. Adding holiday button 6. Change force and error reset position New function for end user · Auto Mode for Heating and Cooling mode · Show Energy Consumption · Set Holiday Mode · 1 stage for 1 day (maximum 99 stages) · Min 25°C to 55°C Day Heating and Cooling Mode: Authorized service partner or Authorized installer can enable the cooling mode through a special operation via the remote controller on site. Pump with 7 speeds: Pump speed can be selected on the remote control. Auto Mode: Automatically changes from heating to cooling depending on outdoor temperature. Energy Consumption: Displays the heat pump’s energy consumption, split by heating, cooling and domestic hot water, and shows total consumption figure. Holiday Mode: Enables the system to resume at the preset temperature after your holiday. 32 AQUAREA Heating feed R1 1/4 New indoor unit design · New A-class pump with 7 speeds · Expansion vessel of 10L · Selectable back-up heater (3/6/9kW) Wire inlet Heating return R1 1/4 Drainage Gas refrigerant connection 5/8 Liquid refrigerant connection 1/4 -3/8 Pressure relief valve Flow switch ANSION · 10l EXP EL VESS ELECTRIC · 3/6/9KW ENT ELEM S PUMP · A CL AS Automatic air purge Water plate heat exchanger Expansion vessel 10l1) Heater assembly 3/6/9kW selectable on the remote control2) Water pump High efficiency pump 1) 6 l for the 3kW, 5kW and 6kW. 2) 3kW for 7 and 9kW, 6kW for 12, 14, 16kW Single Phase, 9kW for 12, 14, 16kW Three Phase. Inverter+ compressor for even greater efficiency Panasonic has clearly demonstrated it status as leaders in this field with over 200 million compressors supplied and the excellent quality and reliability of its heat pumps. With a Panasonic Inverter+ compressor, you can save up to 30% energy compared to a traditional system with no inverter. With a Panasonic Inverter compressor, the heat pump is always producing heat with the maximum of efficiency and adapting the capacity to the element. The advantages of inverter heat pumps. Comparing Inverter and non-Inverter heat pumps. HEAT IN THE LIVING ROOM (UNCOMFORTABLE) COMFORT THE LIVING ROOM COLD IN THE LIVING ROOM (UNCOMFORTABLE) NO INVERTER Slow to start. Takes longer to reach the temperature set point. INVERTER Rapidly reaches the desired temperature. NO INVERTER The temperature oscillates between the two extremes and never stabilises. The temperature falls and then rises quickly, leading to a consumption peak. INVERTER Adjusts the temperature: more comfort and greater savings. Keeps the temperature comfortable all the time. 33 Y 120% B E S A E R INC OF FREE E G A S U THE IT Y* ELECTRIC Heat and produce Domestic Hot Water for free Panasonic has developed an innovative algorithm for its HPM (Heat Pump Manager) which drastically improves the Heat Pump’s use of self-generated electricity from connected Photovoltaic panels. The Heat Pump will take the electricity generation by the solar system into consideration for the heating system and the domestic hot water production, without reducing confort in the house. The HPM (Heat Pump Manager) activates the heat pump based on: · Energy produced by the photovoltaic system. · The consumption requirement of the house, eg if a washing machine is working, the heat pump will not draw electricity from the photovoltaic system to avoid net increases on overall energy consumption and hence maximise efficiency. · Heating demand of the house (in case of high electricity production, the house can be overheated by 1 or 2 degrees, or reduced by 1 or 2 degrees if low production of electricity). As the production of domestic hot water is linked to the level of electricity generated by the solar system, if this was too low, the heat pump would start a normal process to maintain maximum comfort in the house for a given set time (defined by the user). Key points + · Increases the amount of self-consumed electricity from the solar system up to 120%. · Control the heat pump’s energy consumption according to the output of electricity from the PV considering the electric energy consumtion requirement of the house. · Innovative algorithm balancing the consumption of the heat pump and the comfort in the house based on the outside temperature and the energy demand of the building. · Easy configuration of the Heat Pump manager system with the PV system. HPM 34 *Results of simulations for new housing (see next page) AQUAREA Comparison on New housing Increase usage of self production by: 120% Comparison on Old housing Increase usage of self production by: 71% The HPM could increase the energy consumption of the heat pump coming from the Photovoltaic from 352 kWh to 775 kWh a year. Results of simulations: The HPM could increase the energy consumption of the heat pump coming from the Photovoltaic from 526 kWh to 898 kWh a year. Results of simulations: New building Frankfurt (non-optimized) Old building Frankfurt (non-optimized) New building Frankfurt (optimized-eco) PV Production (5,630 kWh/a) 73% (4,129 kWh/a) 27% (1,502 kWh/a) (Energy) To Grid (4,129 kWh) 33% (1,149 kWh) 14% (352 kWh) 67% (2,351 kWh) 86% (2,116 kWh) Consumption of the House (Energy) To Grid (3,706 kWh) 33% (1,149 kWh) Consumption of the HP Consumption of the House 33% (1,149 kWh) Consumption of the HP Consumption of the House Usage of energy in the house Conditions: Installed PV Capacity: 5.64 kWp Household Consumer Demand: 3,500 kWh/a Hotwater Demand: 200 l/day @ 45 °C Insulation Standard (Heat demand): 35 kWh/m2 Controller: Non-Intelligent (Energy) From Grid (4,012 kWh) Conditions: Installed PV Capacity: 5.64 kWp Household Consumer Demand: 3,500 kWh/a Hotwater Demand: 200 l/day @ 40 °C Insulation Standard (Heat demand): 35 kWh/m2 Controller: ECO Conditions: Installed PV Capacity: 5.64 kWp Household Consumer Demand: 3,500 kWh/a Hotwater Demand: 200 l/day @ 45 °C Insulation Standard (Heat demand): 80 kWh/m2 Controller: Non-Intelligent PV: Production of energy From Grid (5,627 kWh) Conditions: Installed PV Capacity: 5.64 kWp Household Consumer Demand: 3,500 kWh/a Hotwater Demand: 200 l/day @ 40 °C Insulation Standard (Heat demand): 80 kWh/m2 Controller: ECO PV: Production of energy How to create added value of the combination PV+HP? · Optimize the HP considering the PV production · When the PV is producing enough to cover the HP consumption, then Tank mode will be forced to heat up the DHW to 55 or 65 degrees · If buffer tank on the installation, temperature on the buffer tank will increase 1-to 5 degrees or up to 55°C. Grid HPM* Home appliances and Lighting 78% (3,276 kWh) Consumption of the HP PV + HP control Electrical meter* Electrical panel Consumption of the House Usage of energy in the house Electrical meter* Photovoltaic solar panels 22% (898 kWh) 67% (2,351 kWh) Consumption of the HP Electrical panel Inverter 33% (1,149 kWh) 88% (3,709 kWh) Usage of energy in the house From Grid (6,060 kWh) PV Production (5,630 kWh/a) 64% (3,583 kWh/a) 36% (2,047 kWh/a) (Energy) To Grid (3,583 kWh) 12% (526 kWh) 67% (2,351 kWh) 62% (1,661 kWh) Old building Frankfurt (optimized-eco) PV Production (5,630 kWh/a) 70% (3,955 kWh/a) 30% (1,675 kWh/a) (Energy) To Grid (3,955 kWh) 32% (775 kWh) 67% (2,351 kWh) Usage of energy in the house (Energy) From Grid (4,467 kWh) PV Production (5,630 kWh/a) 66% (3,706 kWh/a) 34% (1,924 kWh/a) Heating and DHW *Device supply by Panasonic-PAW-HPM-Solar (HPM + 2 Electrical Retors) Standard combination PV+HP. Why the Panasonic HPM can increase by 120% the performance of the combination PV+HP Typical Electricity consumption and production profile WITHOUT Panasonic HPM Typical Electricity consumption and production profile optimize by the Panasonic HPM Temperature in the house : 21 °C +/- 2 °C Temperature in the house : 21 °C +/- 2 °C -4,0 kW -4,0 kW -3,0 kW -3,0 kW -2,0 kW -2,0 kW -1,0 kW -1,0 kW 0 kW 0 kW 1,0 kW 1,0 kW 2,0 kW 2,0 kW 3,0 kW 3,0 kW 4,0 kW 4,0 kW 5,0 kW 5,0 kW 6,0 kW 6,0 kW 0:00 12:00 Total electricity used in the house and by the HP PV production used in the house and by the HP PV production send to the grid Electricity used by the HP 24:00 No optimization of the consumption of the HP, production and consumption only match on 13% 0:00 12:00 By forcing the HP to run when there is production. The Panasonic HPM increases the consumption of free electricity coming from the PV by 56% The HP does not have to work when there is high demand of electricity during the evening for example 24:00 The house temperature is maintained, to ensure comfort. A variation of 1 to 2 degrees can be programmed in order to increase the performance of the system 35 HPM TROL NEW CON ON FUNCTI Control & connectivity Aware of the importance of both control and connectivity in offering the best comfort at the lowest price, Panasonic offers its customers cutting-edge technology, specially designed to ensure our Aquarea heat pump systems deliver maximum performance. You can properly manage the heat pump and perform comprehensive monitoring and control, with all of the features the remote control provides at home, from anywhere in the world thanks to the internet applications Panasonic has created for you. New Connected to a router, all information of the heating system controlled by the HPM is available from internet. Installers, service companies and end user can monitor the installation remotely. Panasonic has developed a new easy start up mode for the HPM. Start your bivalent system in just 10 minutes! 36 AQUAREA OPTIONAL With or without built-in display The next generation of Aquarea Manager This new generation of smart controllers for eco-efficient heating features our versatile stand-alone controller for heating and domestic hot water. Panasonic offers: Trends. Statistics. Consumption Energy Management-Optimization. Alarm. Handling + Maintenance. Complete documentation etc. READY STEADY GO Easy Installation & Easy Configuration Ready: Pre-programmed with up to 610 applications/system diagrams Steady: At start up - state the number of application/system diagram Go: The controller starts working according to selected diagram External touch display with the Heat Pump Manager Key points · Easy selection with the “ready to go” system · Up to 610 preconfiguration installations available on www.panasonicproclub.com · Cascade system possible for big installations. · Bivalent control in order to also manage gas boilers · Able to control 2 mixed heated zones · Smart grid ready · Solar panel mode in order to produce heat when the PV is generating electricity · Online access with control of all parameters. · Easy installation and needs less than 3 minutes to configure a complex system Technical Specification · New function: Smart Setup · Control of 2 x Mixed Heating Circuits · Floor screed dry program · Cascade/bivalent controller · Automatic switch from heating to cooling mode · Night shift: - Internal Energy Manager · Solar collector control · Domestic hot water priority · Easy to startup – easy to operate · 7 output relays · 0-10 V In/Output Signal · 8 Sensor inputs (PT1000) · USB interface (upload, service, remote control, trend) · RS485 interface (com. with additional heat pump) · RS485 interface (for external display) · Built-in backlit text display Easy mounting Simple mounting without screws in the cabinet/door or on DIN-rail. Also possible to mount directly on to the wall. 37 Control your heat pump from wherever you are. Control your comfort and efficiency with the lowest energy consumption M NEW ROO RE TU TEMPERA R SENSO Take control from wherever you are! COMPUTER SMARTPHONE TABLET HOME OFFICE STREET WORK GYM Home or Office Internet Control Ready INTERNET service in the cloud* INTERFACE WIFI AIR CONDITIONING OP TI ON AL CONTROL YOUR HEAT PUMP FROM EVERYWHERE WIRED ROOM TEMPERATURE SENSOR PAW-AW-WIFI-1TE FOR INTESISHOMES INTERNET CONTROL PAW-AW-WIFI-1 IntesisHome for web control PAW-AW-WIFI-1TE IntesisHome for web control with Wired room temperature sensor to display the temperature of the room ROUTER WIFI * Functionalities depend on the license. The information indicated above is subject to changes and updates. What’s Internet Control? Internet Control is a next generation system providing user-friendly remote control of air conditioning or heat pump units from anywhere, using a simple Android or iOS smartphone, tablet or PC via internet with the optional Wired Room temperature sensor, the temperature be display (only with PAW-AW-WIFI-1A. Simple Installation Just connect the Internet Control device to the air conditioner or heat pump with the supplied wire and then link it to your WIFI Access point. Internet Control. Easy to install. Maximum benefit Internet Control is underlined with the slogan “Your home in the cloud”, meaning a simple and easy to handle solution has been considered for every user to manage the device, not requiring any communication or computer skills. No servers. No adaptors. No wires. Just a small box needs to be connected and placed close to the air conditioning indoor unit… and your smartphone, tablet or PC. Your existing WiFi connection does the rest when you are at home. Start the App from your smartphone device, your tablet or your computer, and enjoy a new experience in comfort. And if you are out of home, just launch the App, and manage the air conditioning of your home from the cloud. An intuitive and user-friendly application on the screen of your smartphone or PC that lets you manage the air conditioning unit in the same way you do with the remote controller at home. Internet Control can be downloaded in Apple’s AppStore and Android’s PlayStore. Control your air conditioning with the smart internet control device via smartphones, tablet, PC and smart desktop phone via internet Offering the same functions as if you were at home or office: start/stop, Mode Operation, Set Temperature, Room Temperature etc as well as the new, advanced functionality provided by Internet Control to achieve the best comfort and efficiency with the lowest energy consumption. 38 Case Study: Helen, Panasonic customer “I was sick of heating my house in the mountains on the weekends when I couldn’t go. It was a pointless and annoying expense. But now, with Internet Control, I’ve managed to put the rigidity of weekly programming behind me. If I go then I just put my Panasonic Aquarea heating system on. And if I don’t go then I go to the cinema or the theatre with the money I’ve saved.” AQUAREA Connectivity: Great flexibility for integration into your KNX / Zig Bee / Modbus projects allows fully bi-directional monitoring and control of all the functioning parameters Panasonic works with partners to ensure the optimum solutions for our clients. Our partner has designed a range of interfaces specifically for Panasonic to provide complete monitoring, control and full functionality of the entire Aquarea line-up from KNX, Zig Bee and Modbus installations. This connectivity solution is made by a third party company, please contact Panasonic for more information. Easy control by BMS CONNECTIVITY Interface to connect Aquarea to KNX Reference: PAW-AW-KNX-1i This new Aquarea-KNX interface allows full monitoring and control, bi-directionally, of all the functioning parameters of Aquarea control from KNX installations. · Small dimensions. / Quick installation and possibility of hidden installation. · External power not required. · Direct connection to the unit. · Fully KNX interoperable. Control and monitoring, from sensors or gateways, of the internal variables of the indoor unit and error codes and indication. · Aquarea unit can be controlled simultaneously by the remote control of the Aquarea unit and by KNX devices. Interface to connect Aquarea to Zig Bee Reference: PAW-ZIG-A2W This new Aquarea-Zig Bee home automation interface allows full monitoring and control, bi-directionally, of all the functioning parameters of the Aquarea control from Zig Bee installations. · Small dimensions. / Quick installation. · External power not required. · Direct connection to the Aquarea unit using the same parameters as on the control. · Fully Zig Bee interoperable. Control and monitoring, from sensors or gateways, of the internal variables of the indoor unit and error codes and indication. · Aquarea unit can be controlled simultaneously by the remote control of the Aquarea unit and by Zig Bee devices. Interface to connect Aquarea to Modbus Reference: PAW-AW-MBS-1 This new Aquarea-Modbus RTU Slave interface allows monitoring and control, fully bi-directionally, all the functioning parameters of Aquarea control from Modbus installations. · Small dimensions. / Quick installation and possibility of hidden installation. · External power not required. · Direct connection to the unit. · Fully Modbus interoperable. Control and monitoring, from any BMS or PLC Modbus Master, of internal variables of the indoor unit and error codes and indication. · Aquarea unit can be controlled simultaneously by the remote control of the Aquarea unit and by Modbus Master device. 4 x binary inputs INTERFACE INTERFACE Any standard KNX device Model name PAW-AW-KNX-1i PAW-ZIG-A2W PAW-AW-MBS-1 PAW-AW-WIFI-1 PAW-AW-WIFI-1TE Interface KNX Zig Bee Modbus RTU IntesisHome for web control IntesisHome for web control with Wired room temperature sensor to display the temperature of a room MODBUS Building Management System 39 Aquarea Line-Up! Three Phase Heating only Heating only Heating only Heating only Heating and Heating and Heating and Heating and Heating and Heating and Heating only Heating and Heating and Heating only Heating and Heating and Heating and Heating and cooling cooling cooling cooling cooling cooling cooling cooling cooling cooling cooling cooling Single Phase Bi-Bloc High performance Three Phase Single Phase Three Phase Bi-Bloc T-CAP Bi-Bloc Single Phase Aquarea High Performance for well insulated houses Mono-Bloc Single Phase Three Phase Bi-Bloc Three Phase Single Phase Aquarea T-CAP for cold areas Mono-Bloc Three Phase Single Phase Bi-Bloc Three Phase Single Phase Aquarea HT for retrofit FIGURE 2 (F2) Mono-Bloc Three Phase Single Phase All in One FIGURE 1 (F1) FIGURE 3 (F3) 3kW 5kW WH-ADC0309G3E5 WH-UD03EE5 A (F1) class pump WH-ADC0309G3E5 WH-UD05EE5 A (F1) class pump FIGURE 4 (F4) 6kW FIGURE 5 (F5) 7kW 9kW FIGURE 6 (F6) 12kW 14kW 16kW WH-ADC0309G3E5 WH-ADC0309G3E5 WH-ADC1216G6E5 WH-ADC1216G6E5 WH-ADC1216G6E5 WH-UD07FE5 WH-UD09FE5 WH-UD12FE5 (F1) WH-UD14FE5 (F1) WH-UD16FE5 (F1) A A A A A (F1) (F1) class pump class pump class pump class pump class pump WH-ADC0916G9E8 WH-ADC0916G9E8 WH-ADC0916G9E8 WH-ADC0916G9E8 WH-UD09FE8 WH-UD12FE8 (F1) WH-UD14FE8 (F1) WH-UD16FE8 (F1) A A A A (F1) class pump class pump class pump class pump WH-ADC1216G6E5 WH-ADC1216G6E5 WH-UX09FE5 WH-UX12FE5 (F1) A A (F1) class pump class pump WH-ADC0916G9E8 WH-ADC0916G9E8 WH-UX09FE8 WH-UX12FE8 (F1) A A (F1) class pump class pump WH-SDF03E3E5 WH-UD03EE5 (F2) WH-SDC03E3E5 WH-UD03EE5 (F2) A class pump A class pump WH-SDF05E3E5 WH-UD05EE5 (F2) WH-SDC05E3E5 WH-UD05EE5 (F2) A class pump A class pump WH-SDC07F3E5 WH-UD07FE5 (F4) A class pump A class pump WH-SDC09F3E5 WH-UD09FE5 (F4) WH-SDC09F3E8 WH-UD09FE8 (F5) WH-MDF06E3E5 (F3) WH-MDC05F3E5 (F3) WH-ADC0916G9E8 WH-UX16FE8 (F1) A class pump WH-MDC06E3E5 (F3) A class pump A class pump WH-SDC12F6E5 WH-UD12FE5 (F5) WH-SDC12F9E8 WH-UD12FE8 (F5) A class pump A class pump WH-SDC14F6E5 WH-UD14FE5 (F5) WH-SDC14F9E8 WH-UD14FE8 (F5) A class pump A class pump class pump WH-SDC16F9E8 WH-UD16FE8 (F5) class pump A A class pump WH-MDF09E3E5 (F3) WH-MDC09E3E5 (F3) WH-MDC12C6E5 (F6) WH-MDC14C6E5 (F6) WH-MDC16C6E5 (F6) A WH-MDC09C3E8 (F6) WH-MDC12C9E8 (F6) WH-MDC14C9E8 (F6) WH-MDC16C9E8 (F6) WH-SXC09F3E5 WH-UX09FE5 (F5) WH-SXC12F6E5 WH-UX12FE5 (F5) A class pump WH-SXC09F3E8 WH-UX09FE8 (F5) A class pump A class pump WH-SXC12F9E8 WH-UX12FE8 (F5) A class pump A class pump WH-MXC09D3E5 (F6) WH-MXC12D6E5 (F6) WH-MXC09D3E8 (F6) WH-MXC12D9E8 (F6) WH-SHF09F3E5 WH-UH09FE5 (F5) WH-SHF12F6E5 WH-UH12FE5 (F5) WH-SHF09F3E8 WH-UH09FE8 (F5) A class pump A class pump WH-SHF12F9E8 WH-UH12FE8 (F5) A class pump A class pump WH-MHF09D3E5 (F6) WH-MHF12D6E5 (F6) WH-MHF09D3E8 (F6) WH-MHF12D9E8 (F6) Low connectivity : control of 3 way valve, tank heater On/Off signal, tank thermostat signal reception, On/Off from external control, weekly timer. High connectivity : Low connectivity + solar panels connection, room thermostat connection. * Cooling mode activation possible by software. This activation can only be done by service partner. 40 WH-SDC16F6E5 WH-UD16CE5 (F5) WH-SXC16F9E8 WH-UX16FE8 (F5) A class pump NEW AQUAREA A class pump SEASONAL EFFICIENCY Aquarea All in One Bi-Bloc (Inverter) High performance 3kW 5kW 7kW T-CAP (High Capacity for cold areas) 9kW 12kW 9kW 12kW 14kW 16kW 16kW Aquarea Bi-Bloc (Inverter) High performance 3kW 9kW 12kW T-CAP (High Capacity for cold areas) 5kW 7kW 9kW 12kW AQUAREA HT 9kW 12kW 14kW 16kW 16kW Aquarea Mono-Bloc (Inverter) High performance 9kW 12kW T-CAP (High Capacity for cold areas) 5kW 6kW 9kW 12kW AQUAREA HT 9kW 12kW 14kW 16kW * Not all products have A class pump. Bi-Bloc Mono-Bloc Aquarea High Performance Aquarea T-CAP Aquarea HT Aquarea High Performance Aquarea T-CAP Aquarea HT 5.00 COP 100% Output water 65 ºC 5.08 COP Output water high efficiency 100% AQUAREA T-CAP HIGH TEMP HEAT PUMP AQUAREA HIGH PERFORMANCE AQUAREA T-CAP HIGH TEMP HEAT PUMP capacity at -15 ºC high efficiency AQUAREA HIGH PERFORMANCE capacity at -15 ºC 65 ºC Heating only Heating and cooling Heating only Heating only Heating and cooling Heating only Single Phase / Three Phase Single Phase / Three Phase Single Phase / Three Phase Single Phase / Three Phase 41 NEW * Aquarea All in One High performance Bi-Bloc Single Phase Heating and Cooling SEASONAL EFFICIENCY Panasonic has developed a highly efficient solution, easy to install. Technical focus · Space saving: 1827 x 600 x 720 (H x W x D) · Reduce installation costs · Piping on the bottom of the All in One (easy to install) · Reduce timing and minimize installation errors WH-UD03EE5 WH-UD05EE5 A class pump · Easy remote control to set up · Electrical connections on the front · Reduce installation spaces · All piping connections at bottom of the indoor unit · Easier installation and maintenance · New remote control functions * Cooling mode activation possible by software. This activation can only be done by service partner. Optional Controllers WH-UD07FE5 WH-UD09FE5 WH-UD12FE5 WH-UD14FE5 WH-UD16FE5 WH-UD09FE8 WH-UD12FE8 WH-UD14FE8 WH-UD16FE8 Aquarea Manager with LCD. PAW-HPM1 Aquarea Manager touch screen. PAW-HPMED for HPM Wireless LCD room thermostat with weekly timer. PAW-A2W-RTWIRELESS Tank in the indoor unit Hidrokit in the indoor unit Single Phase (Power to indoor) Three Phase (Power to indoor) Kit KIT-ADC3GE5 KIT-ADC5GE5 KIT-ADC7GE5 KIT-ADC9GE5 KIT-ADC12GE5 KIT-ADC14GE5 KIT-ADC16GE5 KIT-ADC9GE8 KIT-ADC12GE8 KIT-ADC14GE8 WH-ADC0309G3E5 WH-ADC1216G6E5 WH-ADC0916G9E8 Indoor unit Outdoor unit WH-UD03EE5 WH-UD05EE5 WH-UD07FE5 WH-UD09FE5 WH-UD12FE5 WH-UD14FE5 WH-UD16FE5 WH-UD09FE8 WH-UD12FE8 WH-UD14FE8 Heating capacity at +7°C kW 3,20 5,00 7,00 9,00 12,00 14,00 16,00 9,00 12,00 14,00 COP at +7°C (heating water at 35°C) 5,00 4,63 4,46 4,13 4,75 4,57 4,28 4,85 4,75 4,57 Heating capacity at +2°C (heating water at 35°C) kW 3,20 4,20 6,55 6,70 11,40 12,40 13,00 9,00 11,40 12,40 COP at +2°C (heating water at 35°C) 3,56 3,11 3,34 3,13 3,45 3,36 3,29 3,59 3,45 3,36 Heating capacity at -7°C kW 3,20 4,20 5,15 5,90 10,00 10,70 11,40 9,00 10,00 10,70 COP at -7°C 2,69 2,59 2,68 2,52 2,74 2,71 2,68 2,85 2,74 2,71 Cooling capacity at 35°C kW 3,20 4,50 6,00 7,00 10,00 11,50 12,20 7,00 10,00 11,50 EER at 35°C (cooling water at 7/12°C) 3,08 2,69 2,63 2,43 2,81 2,64 2,57 3,17 2,81 2,64 Indoor unit Dimensions HxWxD mm 1.827x600x720 1.827x600x720 1.827x600x720 1.827x600x720 1.827x600x720 1.827x600x720 1.827x600x720 1.827x600x720 1.827x600x720 1.827x600x720 Weight kg Water pipe connector mm R1 1/4 R1 1/4 R1 1/4 R1 1/4 R1 1/4 R1 1/4 R1 1/4 R1 1/4 R1 1/4 R1 1/4 A class Pump No. of Speed 7 7 7 7 7 7 7 7 7 7 Input power (Min/Max.) W Min: 21 W at 10l/min / Max: 135 W at 53.8l/min Heating water flow (∆T=5 K. 35°C) l/min 9,2 14,3 20,1 25,8 34,4 40,1 45,9 25,8 34,4 40,1 Capacity of integrated electric heater kW 3 3 3 3 6 6 6 3 9 9 Input Power Heating / Cooling kW 0,64 / 1,04 1,08 / 1,67 1,59 / 2,30 2,20 / 2,90 2,57 / 3,60 3,11 / 4,40 3,78 / 4,80 1,90 / 2,25 2,57 / 3,55 3,11 / 4,40 Running current Heating / Cooling A 3,00 / 4,8 5,00 / 7,6 7,30 / 10,40 10,10 / 13,10 11,70 / 16,10 14,10 / 19,70 17,10 / 21,50 2,90 / 3,40 3,90 / 5,30 4,70 / 6,60 Current 1 / Current 2 A 21,0 / 26,0 22,9 / 26,0 24,0 / 26,0 25,0 / 26,0 26,0 / 26,0 11,8 / 13,0 8,8 / 13,0 9,4 / 13,0 Recommended Fuse A 30 / 15 30 / 15 30 / 30 30 / 30 30 / 30 30 / 30 30 / 30 16 / 16 16 / 16 16 / 16 Recommended power cable section mm² 4,0 / 2,5 4,0 / 2,5 4,0 / 4,0 4,0 / 4,0 4,0 / 4,0 4,0 / 4,0 4,0 / 4,0 2,5 / 2,5 2,5 / 2,5 2,5 / 2,5 Water volume L 200 200 200 200 200 200 200 200 200 200 Maximum water temperature °C 65 65 65 65 65 65 65 65 65 65 Material inside tank Stainless steel Stainless steel Stainless steel Stainless steel Stainless steel Stainless steel Stainless steel Stainless steel Stainless steel Stainless steel Exchange surface m² 2,1 2,1 2,1 2,1 2,1 2,1 2,1 2,1 2,1 2,1 Warranty of the stainless steel tank 10 years 10 years 10 years 10 years 10 years 10 years 10 years 10 years 10 years 10 years Maintenance required on the tank No No No No No No No No No No Outdoor unit dB(A) / dB 47 / 65 48 / 66 48 / 66 49 / 67 50 / 67 51 / 68 53 / 70 49 / 65 50 / 66 51 / 71 Sound pressure level / Sound power level mm / kg 622 x 824 x 298 / 39 795 x 900 x 320 / 66 1.340 x 900 x 320 / 106 Dimensions / Weight H x W x D mm (Inch) 6,35 (1/4) / 12,7 (1/2) 6,35 (1/4) / 15,88 (5/8) 9,52 (3/8) / 15,88 (5/8) Pipe diameter Liquid / Gas 1,20 / 20 1,45 / 30 1,45 / 30 2,75 / 50 2,75 / 50 2,75 / 50 2,75 / 50 2,75 / 50 2,75 / 50 Refrigerant / Additional gas amount (R410A) kg / g/m 1,20 / 20 Pipe length range m 3-15 3-15 3 – 30 3 – 30 3 – 30 3 – 30 3 – 30 3 – 30 3 – 30 3 – 30 7 / 10 7 / 10 7 / 10 7 / 10 7 / 10 7 / 10 7 / 10 7 / 10 7 / 10 7 / 10 Pipe length for nominal capacity / additional gas m Elevation dif. (in/out) m 5 5 20 20 20 20 20 20 20 20 Operation range Outdoor ambient °C -20 to 35 -20 to 35 -20 to 35 -20 to 35 -20 to 35 -20 to 35 -20 to 35 -20 to 35 -20 to 35 -20 to 35 Water outlet at -2/-7/-15 °C 20 - 55 / 5 – 20 20 - 55 / 5 – 20 20 – 55 / 5 – 20 20 – 55 / 5 – 20 25 – 55 / 5 – 20 25 – 55 / 5 – 20 25 – 55 / 5 – 20 25 – 55 / 5 – 20 25 – 55 / 5 – 20 25 – 55 / 5 – 20 5.00 COP high efficiency IO N OP T Control Ready AL Internet INTERNET CONTROL AQUAREA HIGH PERFORMANCE INTERNET CONTROL READY: Optional. 42 High efficiency heating Environmentally friendly Down to Boiler Solar Domestic Easy refrigerant -20 ºC in heating mode connection panels connection hot water control by BMS R410A OUTDOOR TEMPERATURE RETROFIT SOLAR KIT DHW CONNECTIVITY 5 year compressor warranty KIT-ADC16GE8 WH-UD16FE8 16,00 4,28 13,00 3,29 11,40 2,68 12,20 2,57 1.827x600x720 R1 1/4 7 45,9 9 3,78 / 4,80 5,70 / 7,20 9,9 / 13,0 16 / 16 2,5 / 2,5 200 65 Stainless steel 2,1 10 years No 53 / 68 2,75 / 50 3 – 30 7 / 10 20 -20 to 35 25 – 55 / 5 – 20 COP classification is at 230 V only in accordance with EU directive 2003/32/EC. Sound pressure measured at 1 m from the outdoor unit and at 1.5 m height. Performance in agreement with EN14511. 1) Insulated tested under EN12897. * Preliminary design. Significant changes may occur. NEW AQUAREA * Aquarea All in One T-CAP Bi-Bloc Single Phase / Three Phase Heating And Cooling SEASONAL EFFICIENCY All the benefits of the T-CAP All in ONE unit! Panasonic has developed a highly efficient solution, easy to install. A class pump · Easy remote control to set up · Electrical connections on the front · Reduce installation spaces · All piping connections at bottom of the indoor unit · Easier installation and maintenance · 1 phase and 3 phase · New remote control functions Technical focus · Space saving: 1827 x 600 x 720 (H x W x D) · Reduce installation costs · Piping on the bottom of the All in One (easy to install) · Reduce timing and minimize installation errors Optional Controllers WH-UX09FE5 WH-UX12FE5 WH-UX16FE8 WH-UX09FE8 WH-UX12FE8 Aquarea Manager with LCD. PAW-HPM1 Tank in the indoor unit Hidrokit in the indoor unit Kit Indoor unit Outdoor unit Heating capacity at +7°C COP at +7°C (heating water at 35°C) Heating capacity at +2°C (heating water at 35°C) COP at +2°C (heating water at 35°C) Heating capacity at -7°C COP at -7°C Cooling capacity at 35°C EER at 35°C (cooling water at 7/12°C) Indoor unit Dimensions HxWxD Weight Water pipe connector A class Pump No. of Speed Input power (Min/Max.) Heating water flow (∆T=5 K. 35°C) Capacity of integrated electric heater Input Power Heating / Cooling Running current Heating / Cooling Current 1 / Current 2 Recommended Fuse Recommended power cable section Water volume Maximum water temperature Material inside tank Exchange surface Warranty of the Stainless steel tank Maintenance required on the tank Outdoor unit Sound pressure level / Sound power level Dimensions / Weight H x W x D Pipe diameter Liquid / Gas Refrigerant / Additional gas amount (R410A) Pipe length range Pipe length for nominal capacity / additional gas Elevation dif. (in/out) Operation range Outdoor ambient Water outlet at -2/-7/-15 4.85 COP high efficiency IO N OP T Control Ready AL Internet INTERNET CONTROL AQUAREA HIGH PERFORMANCE INTERNET CONTROL READY: Optional. High efficiency heating kW kW kW kW mm kg W l/min kW kW A A A mm² L °C m² dB(A) / dB mm / kg mm (Inch) kg / g/m m m m °C °C Wireless LCD room thermostat with weekly timer. PAW-A2W-RTWIRELESS Aquarea Manager touch screen. PAW-HPMED for HPM Single Phase (Power to indoor) KIT-AXC9FE5 WH-ADC1216G6E5 WH-UX09FE5 9,00 4,85 9,00 3,59 9,00 2,85 7,00 3,17 KIT-AXC12FE5 WH-ADC1216G6E5 WH-UX12FE5 12,00 4,75 12,00 3,44 12,00 2,72 10,00 2,81 Three Phase (Power to indoor) KIT-AXC9FE8 WH-ADC0916G9E8 WH-UX09FE8 9,00 4,85 9,00 3,59 9,00 2,85 7,00 3,17 KIT-AXC12FE8 WH-ADC0916G9E8 WH-UX12FE8 12,00 4,75 12,00 3,44 12,00 2,72 10,00 2,81 KIT-AXC16FE8 WH-ADC0916G9E8 WH-UX16FE8 16,00 4,28 16,00 3,10 16,00 2,49 12,20 2,57 1.827 x 600 x 720 1.827 x 600 x 720 1.827 x 600 x 720 1.827 x 600 x 720 1.827 x 600 x 720 R1¼ 7 R1¼ 7 25,8 6 1,90 8,8 (10,4) 25,0 / 26,0 30 / 30 4,0 / 4,0 200 65 Stainless steel 2,1 10 years No 34,4 6 2,57 11,9 (16,7) 29,0 / 26,0 30 / 30 4,0 / 4,0 200 65 Stainless steel 2,1 10 years No 49 / 66 1.340 x 900 x 320 / 107 9,52 (3/8) / 15,88 (5/8) 3,10 / 50 3 – 30 7 / 10 20 -20 to 35 25 – 55 / 5 – 20 50 / 67 1.340 x 900 x 320 / 107 9,52 (3/8) / 15,88 (5/8) 3,10 / 50 3 – 30 7 / 10 20 -20 to 35 25 – 55 / 5 – 20 Environmentally friendly Down to Boiler R1¼ R1¼ 7 7 Min: 21 W at 10l/min / Max: 135 W at 53.8l/min 25,8 34,4 9 9 1,90 2,57 2,9 (3,4) 3,9 (5,4) 14,7 / 13,0 11,9 / 13,0 16 / 16 16 / 16 / 16 2,5 / 2,5 2,5 / 2,5 200 200 65 65 Stainless steel Stainless steel 2,1 2,1 10 years 10 years No No Solar 49 / 66 1.340 x 900 x 320 / 110 9,52 (3/8) / 15,88 (5/8) 3,10 / 50 3 – 30 7 / 10 20 -20 to 35 25 – 55 / 5 – 20 Domestic Easy refrigerant -20 ºC in heating mode connection panels connection hot water control by BMS R410A OUTDOOR TEMPERATURE RETROFIT SOLAR KIT DHW CONNECTIVITY R1¼ 7 45,9 9 2,57 7,2 15,5 / 13,0 16 / 16 2,5 / 2,5 200 65 Stainless steel 2,1 10 years No 50 / 67 1.340 x 900 x 320 / 110 9,52 (3/8) / 15,88 (5/8) 3,10 / 50 3 – 30 7 / 10 20 -20 to 35 25 – 55 / 5 – 20 5 year compressor warranty 50 / 67 1.340 x 900 x 320 / 110 9,52 (3/8) / 15,88 (5/8) 2,90 / 50 3 – 30 7 / 10 20 -20 to 35 25 – 55 / 5 – 20 COP classification is at 230 V only in accordance with EU directive 2003/32/EC. Sound pressure measured at 1 m from the outdoor unit and at 1.5 m height. Performance in agreement with EN14511. 1) Insulated tested under EN12897. * Preliminary design. Significant changes may occur. 43 AQUAREA HIGH PERFORMANCE BI-BLOC SINGLE PHASE HEATING ONLY - SDF HEATING AND COOLING - SDC 3 AND 5KW A DESIGNED FOR LOW CONSUMPTION HOMES The 3 and 5kW is specially designed for low energy homes and achieves an impressive COP of 5 (on the 3.2kW). Thanks to the system’s high degree of technology and advanced control, it is able to maintain a high capacity and efficiency even at -7°C and -15°C. The Aquarea’s software is optimised to the requirements of low consumption homes in order to maximise energy efficiency. Whatever the weather, Aquarea can work even at -20°C. The compact design of the outdoor unit makes installation very easy. class pump · Efficient control of room temperature based on the outdoor temperature, indoor temperature using the Aquarea Manager. · Super efficient: COP of 5 in the 3.2kW! · A Class Pump · Special software for low consumption homes with minimum output temperature: 20°C · Works down to -20°C · Automatic Air purge valve · Display of the compressor frequency Technical focus Optional Controllers WH-UD03EE5 WH-UD05EE5 Aquarea Manager with LCD. PAW-HPM1 Kit Indoor unit Outdoor unit Heating capacity at +7°C COP at +7°C (heating water at 35°C) Heating capacity at +2°C (heating water at 35°C) COP at +2°C (heating water at 35°C) Heating capacity at -7°C COP at -7°C Cooling capacity at 35°C EER at 35°C (cooling water at 7/12°C) Indoor unit Dimensions HxWxD Weight Water pipe connector A class Pump No. of Speed Input power (Min/Max.) Heating water flow (ΔT=5 K. 35°C) Capacity of integrated electric heater Input Power H/C Running and Starting current H / C Current 1 / Current 2 Recommended Fuse Recommended power cable section Outdoor unit Sound pressure level Sound power level Dimensions HxWxD Weight Pipe diameter Liquid Gas Refrigerant (R410A) Pipe length range Pipe length for nominal capacity Pipe length for additional gas Additional gas amount (R410A) Elevation difference (in/out) Operation range Outdoor ambient Water outlet at -2/-7/-15 Single Phase Heating Only KIT-WF03C3E5 WH-SDF03E3E5 WH-UD03EE5 3,20 5,00 3,20 3,56 3,20 2,69 - KIT-WF05C3E5 WH-SDF05E3E5 WH-UD05EE5 5,00 4,63 4,20 3,11 4,20 2,59 - 892 x 502 x 353 43 28 Variable Speed 892 x 502 x 353 43 28 Variable Speed W l/min kW kW A A A mm² 9,2 3 0,64 / 1,04 3 / 4,8 11,0 / 26,0 15 / 30 2,5 / 4,0 14,3 3 1,08 / 1,67 5 / 7,6 12,0 / 26,0 15 / 30 2,5 / 4,0 dB(A) dB mm kg mm (Inch) mm (Inch) kg m m m g/m m °C °C 47 65 622 x 824 x 298 39 6,35 (1/4) 12,7 (1/2) 1,20 3-15 7 10 20 5 -20 to 35 20 - 55 48 66 622 x 824 x 298 39 6,35 (1/4) 12,7 (1/2) 1,20 3-15 7 10 20 5 -20 to 35 20 - 55 kW kW kW kW mm kg mm Single Phase Heating and Cooling KIT-WC03C3E5 WH-SDC03E3E5 WH-UD03EE5 3,20 5,00 3,20 3,56 3,20 2,69 3,20 3,08 892 x 502 x 353 44 28 Variable Speed Min: 21 W at 10l/min / Max: 135 W at 53.8l/min 9,2 3 0,64 / 1,04 3 / 4,8 11,0 / 26,0 15 / 30 2,5 / 4,0 47 65 622 x 824 x 298 39 6,35 (1/4) 12,7 (1/2) 1,20 3-15 7 10 20 5 -20 to 35 20 - 55 COP classification is at 230 V only in accordance with EU directive 2003/32/EC. Sound pressure measured at 1 m from the outdoor unit and at 1.5 m height. Performance in agreement with EN14511. 5.00 COP high efficiency IO OP T Control Ready N AL Internet INTERNET CONTROL AQUAREA HIGH PERFORMANCE INTERNET CONTROL READY: Optional. 44 High efficiency heating Easy Boiler Solar connection heating mode panels connection hot water refrigerant -20 ºC in control by BMS R410A OUTDOOR TEMPERATURE RETROFIT SOLAR KIT DHW CONNECTIVITY Environmentally friendly Down to Wireless LCD room thermostat with weekly timer. PAW-A2W-RTWIRELESS Aquarea Manager touch screen. PAW-HPMED for HPM Domestic 5 year compressor warranty KIT-WC05C3E5 WH-SDC05E3E5 WH-UD05EE5 5,00 4,63 4,20 3,11 4,20 2,59 4,50 2,69 892 x 502 x 353 44 28 Variable Speed 14,3 3 1,08 / 1,67 5 / 7,6 12,0 / 26,0 15 / 30 2,5 / 4,0 48 66 622 x 824 x 298 39 6,35 (1/4) 12,7 (1/2) 1,20 3-15 7 10 20 5 -20 to 35 20 - 55 AQUAREA Aquarea High Performance Bi-Bloc Single Phase / Three Phase Heating And Cooling - SDC A SEASONAL EFFICIENCY The Aquarea SDC range adapts well in an existing install with a boiler backup, and in a new application with underfloor heating, low temperature radiators or even fan-coil heaters. This range can also be connected to a solar kit in order to increase efficiency and minimize the impact on the ecosystem. Finally, it is possible to connect a thermostat for better heating and cooling control and management. class pump Technical focus · NEW! New remote control functions · Efficient control of room temperature based on the outdoor temperature, indoor temperature using the Aquarea Manager. · Optional Smartphone control · Range from 7 to 16kW, Single and Three Phase · Maximum hydraulic module output temperature: 55°C · Works down to -20°C · Maximum 30 m rise between the outdoor unit and the hydraulic module · Cooling temperature range 5–20°C Optional Controllers WH-UD07FE5 WH-UD09FE5 WH-UD12FE5 WH-UD14FE5 WH-UD16FE5 WH-UD09FE8 WH-UD12FE8 WH-UD14FE8 WH-UD16FE8 Kit Indoor unit Outdoor unit Heating capacity at +7°C COP at +7°C (heating water at 35°C) Heating capacity at +2°C COP at +2°C (heating water at 35°C) Heating capacity at -7°C COP at -7°C (heating water at 35°C) Cooling capacity at 35°C (cooling water at 7°C) EER at 35°C (cooling water at 7°C) Indoor unit Dimensions HxWxD Weight Water pipe connector Pump No. of Speed Input power (Min/Max.) Heating water flow (∆T=5 K. 35°C) Capacity of integrated electric heater Input Power Heating / Cooling Running and Starting current Heating / Cooling Current 1 / Current 2 Recommended Fuse Recommended power cable section Outdoor unit Sound pressure level Sound power level Dimensions / Weight HxWxD Pipe diameter Liquid / Gas Refrigerant (R410A) Pipe length range Pipe length for nominal capacity Pipe length for additional gas Additional gas amount (R410A) Elevation difference (in/out) Operation range Outdoor ambient Water outlet at -2/-7/-15 Heating / Cooling Aquarea Manager with LCD. PAW-HPM1 Single Phase (Power to indoor) KIT-WC07F3E5¹ KIT-WC09F3E5¹ WH-SDC07F3E5 WH-SDC09F3E5 WH-UD07FE5 WH-UD09FE5 7,00 9,00 4,46 4,13 6,55 6,70 3,34 3,13 5,15 5,90 2,68 5,52 6,00 7,00 2,61 2,41 KIT-WC12F6E5² WH-SDC12F6E5 WH-UD12FE5 12,0 4,74 11,40 3,44 10,00 2,73 10,00 2,81 KIT-WC14F6E5² WH-SDC14F6E5 WH-UD14FE5 14,00 4,56 12,40 3,36 10,70 2,70 11,50 2,64 892 x 502 x 353 43 R1 1/4 7 892 x 502 x 353 43 R1 1/4 7 892 x 502 x 353 45 R1 1/4 7 20,1 3 1,59 / 2,30 7,30 / 10,40 21,0 / 26,0 30 / 30 4,0 / 4,0 25,8 3 2,20 / 2,90 10,10 / 13,10 22,9 / 26,0 30 / 30 4,0 / 4,0 34,4 6 2,53 / 3,56 11,50 / 16,00 24,0 / 26,0 30 / 30 4,0 / 4,0 892 x 502 x 353 892 x 502 x 353 892 x 502 x 353 46 46 46 R1 1/4 R1 1/4 R1 1/4 7 7 7 Min: 21 W at 10l/min / Max: 135 W at 53.8l/min 40,1 45,9 25,8 6 6 3 3,07 / 4,36 3,74 / 4,76 1,86 / 2,21 13,90 / 19,50 16,90 / 21,30 2,90 / 3,40 25,0 / 26,0 26,0 / 26,0 11,8 / 13,0 30 / 30 30 / 30 16 / 16 4,0 / 4,0 4,0 / 4,0 2,5 / 2,5 50 67 51 68 kW kW kW kW mm kg W l/min kW kW A A A mm² dB(A) dB mm / kg mm (Inch) kg m m m g/m m °C °C 48 66 49 67 795 x 900 x 320 / 66 6,35 (1/4) / 15,88 (5/8) 1,45 1,45 3 – 30 3 – 30 7 7 10 10 30 30 20 20 -20 to 35 -20 to 35 25 – 55 / 5 – 20 25 – 55 / 5 – 20 Wireless LCD room thermostat with weekly timer. PAW-A2W-RTWIRELESS Aquarea Manager touch screen. PAW-HPMED for HPM KIT-WC16F6E5² WH-SDC16F6E5 WH-UD16FE5 16,00 4,28 13,00 3,28 11,40 2,68 12,20 2,56 Three Phase (Power to indoor) KIT-WC09F3E8³ KIT-WC12F9E8³ WH-SDC09F3E8 WH-SDC12F9E8 WH-UD09FE8 WH-UD12FE8 9,00 12,00 4,84 4,14 9,00 11,40 3,59 3,44 9,00 10,00 2,85 2,23 7,00 10,00 3,17 2,81 53 70 KIT-WC14F9E8³ WH-SDC14F9E8 WH-UD14FE8 14,00 4,56 12,40 3,36 10,70 2,70 11,50 2,64 KIT-WC16F9E8³ WH-SDC16F9E8 WH-UD16FE8 16,00 4,28 16,00 3,28 11,40 2,68 12,20 2,56 892 x 502 x 353 46 R1 1/4 7 892 x 502 x 353 47 R1 1/4 7 892 x 502 x 353 47 R1 1/4 7 34,4 9 2,53 / 3,56 3,90 / 5,30 8,8 / 13,0 16 / 16 2,5 / 2,5 40,1 9 3,07 / 4,36 4,70 / 6,60 9,4 / 13,0 16 / 16 2,5 / 2,5 45,9 9 3,74 / 4,76 5,70 / 7,20 9,9 / 13,0 / 16 / 16 2,5 / 2,5 51 68 53 70 2,55 3 – 30 7 10 50 20 -20 to 35 25 – 55 / 5 – 20 2,55 3 – 30 7 10 50 20 -20 to 35 25 – 55 / 5 – 20 49 50 66 67 1.340 x 900 x 320 / 101 9,52 (3/8) / 15,88 (5/8) 2,55 2,55 2,55 2,55 2,55 3 – 30 3 – 30 3 – 30 3 – 30 3 – 30 7 7 7 7 7 10 10 10 10 10 50 50 50 50 50 20 20 20 20 20 -20 to 35 -20 to 35 -20 to 35 -20 to 35 -20 to 35 25 – 55 / 5 – 20 25 – 55 / 5 – 20 25 – 55 / 5 – 20 25 – 55 / 5 – 20 25 – 55 / 5 – 20 COP classification is at 230 V only in accordance with EU directive 2003/32/EC. Sound pressure measured at 1 m from the outdoor unit and at 1.5 m height. Performance in agreement with EN14511. 1) Available from September 2014. 2) Available from May 2014. 3) Available from June 2014. 4.84 COP high efficiency IO N OP T Control Ready AL Internet INTERNET CONTROL AQUAREA HIGH PERFORMANCE High efficiency heating Environmentally friendly Down to Boiler Solar Domestic Easy refrigerant -20 ºC in heating mode connection panels connection hot water control by BMS R410A OUTDOOR TEMPERATURE RETROFIT SOLAR KIT DHW CONNECTIVITY 5 year compressor warranty INTERNET CONTROL READY: Optional. 45 NEW AQUAREA T-CAP BI-BLOC SINGLE PHASE / THREE PHASE HEATING AND COOLING - SXC SEASONAL EFFICIENCY The new SXC is ideal for residential properties which don’t have an external boiler and require a maintained capacity level. T-CAP stands for Total Capacity. This new line-up is able to maintain the same nominal capacity even at -15°C without the help of an electrical booster heater. T-CAP is also able to provide extremely high efficiency, whatever the outside temperature or the water temperature. The SXC adapts well in an existing install with a boiler backup, and in a new application with underfloor heating, low temperature radiators or even fan-coil heaters. This Range can also be connected to a solar kit in order to increase efficiency and minimize the impact on the ecosystem. Finally, it is possible to connect a thermostat for even better heating or cooling control and management. A class pump Technical focus · NEW! 16kW Model: Maintains 16kW capacity at outdoor temperatures down to -15°C · NEW! New remote control functions · Efficient control of room temperature based on the outdoor temperature, indoor temperature using the Aquarea Manager. · Optional Smartphone control · Range from 9 to 16kW, Single and Three Phase · Maximum hydraulic module output temperature: 55°C · Works down to -20°C (Cooling temperature range 5–20°C) · Constant capacity at outdoor temperatures down to -15°C · Maximum 20 m rise between the outdoor unit and the hydraulic module Optional Controllers WH-UX09FE5 WH-UX12FE5 WH-UX09FE8 WH-UX12FE8 WH-UX16FE8 Aquarea Manager with LCD. PAW-HPM1 Kit Indoor unit Outdoor unit Heating capacity at +7°C (heating water at 35°C) COP at +7°C (heating water at 35°C) Heating capacity at +2°C (heating water at 35°C) COP at +2°C (heating water at 35°C) Heating capacity at -7°C (heating water at 35°C) COP at -7°C (heating water at 35°C) Cooling capacity at 35°C (cooling water at 7°C) EER at 35°C (cooling water at 7°C) Indoor unit Dimensions HxWxD Weight Water pipe connector Pump No. of Speed Input power (Min/Max.) Heating water flow (ΔT=5 K. 35°C) Capacity of integrated electric heater Input Power Starting Current Current 1 / Current 2 Recommended Fuse Recommended power cable section Outdoor unit Sound pressure level Sound power level Dimensions / Weight HxWxD Pipe diameter Liquid / Gas Refrigerant (R410A) Pipe length range Pipe length for nominal capacity Pipe length for additional gas Additional gas amount (R410A) Elevation difference (in/out) Operation range Outdoor ambient Water outlet at -2/-7/-15 Heating / Cooling kW kW kW kW mm kg Aquarea Manager touch screen. PAW-HPMED for HPM Single Phase (Power to indoor) KIT-WXC09F3E5 KIT-WXC12F6E5 WH-SXC09F3E5 WH-SXC12F6E5 WH-UX09FE5 WH-UX12FE5 9,00 12,00 4,84 4,74 9,00 12,00 3,59 3,44 9,00 12,00 2,85 2,72 7,00 10,00 3,17 2,81 892 x 502 x 353 44 R1¼ 7 892 x 502 x 353 45 R1¼ 7 W l/min kW kW A A A mm² 25,8 3 1,86 10,2 25,0 / 26,0 30 / 30 4,0 / 4,0 34,4 6 2,53 16,5 29,0 / 26,0 30 / 30 4,0 / 4,0 dB(A) dB mm / kg mm (Inch) kg m m m g/m m °C °C 49 66 1.340 x 900 x 320 / 107 9,52 (3/8) / 15,88 (5/8) 2,85 3 – 30 7 10 50 20 -20 to 35 25 – 55 / 5 – 20 50 67 1.340 x 900 x 320 / 107 9,52 (3/8) / 15,88 (5/8) 2,85 3 – 30 7 10 50 20 -20 to 35 25 – 55 / 5 – 20 Three Phase (Power to indoor) KIT-WXC09F3E8 KIT-WXC12F9E8 WH-SXC09F3E8 WH-SXC12F9E8 WH-UX09FE8 WH-UX12FE8 9,00 12,00 4,84 4,74 9,00 12,00 3,59 3,44 9,00 12,00 2,85 2,72 7,00 10,00 3,17 2,81 892 x 502 x 353 892 x 502 x 353 45 46 R1¼ R1¼ 7 7 Min: 21 W at 10l/min / Max: 135 W at 53.8l/min 25,8 34,4 3 9 1,86 2,53 3,4 5,4 14,7 / 13,0 11,9 / 13,0 16 / 16 16 / 16 2,5 / 2,5 2,5 / 2,5 49 66 1.340 x 900 x 320 / 109 9,52 (3/8) / 15,88 (5/8) 2,85 3 – 30 7 10 50 20 -20 to 35 25 – 55 / 5 – 20 50 67 1.340 x 900 x 320 / 109 9,52 (3/8) / 15,88 (5/8) 2,85 3 – 30 7 10 50 20 -20 to 35 25 – 55 / 5 – 20 COP classification is at 230 V only in accordance with EU directive 2003/32/EC. Sound pressure measured at 1 m from the outdoor unit and at 1.5 m height. Performance in agreement with EN14511. 100% IO OP T Control Ready N AL Internet INTERNET CONTROL capacity at -15 ºC AQUAREA T-CAP INTERNET CONTROL READY: Optional. 46 High efficiency heating Easy Boiler Solar connection heating mode panels connection hot water refrigerant -20 ºC in control by BMS R410A OUTDOOR TEMPERATURE RETROFIT SOLAR KIT DHW CONNECTIVITY Environmentally friendly Down to Domestic 5 year compressor warranty Wireless LCD room thermostat with weekly timer. PAW-A2W-RTWIRELESS KIT-WXC16F9E8 WH-SXC16F9E8 WH-UX16FE8 16,00 4,28 16,00 3,10 16,00 2,49 12,20 2,57 892 x 502 x 353 52 R1¼ 7 45,9 9 3,74 7,2 15,5 / 13,0 16 / 16 2,5 / 2,5 53 70 1.340 x 900 x 320 / 110 9,52 (3/8) / 15,88 (5/8) 2,90 3 – 30 7 10 50 20 -20 to 35 25 – 55 / 5 – 20 AQUAREA AQUAREA HT BI-BLOC SINGLE PHASE / THREE PHASE HEATING ONLY - SHF SEASONAL EFFICIENCY Aquarea HT is able to deliver water heated to 65°C with the Heat Pump alone. For a house with high temperature radiators (for example, cast iron radiators), the Aquarea High Temperature Solution is most suited as it provides output water temperatures of 65°C even at -20°C. A class pump Technical focus · NEW! New remote control functions · Efficient control of room temperature based on the outdoor temperature, indoor temperature using the Aquarea Manager. · Optional Smartphone control · Range from 9 to 12kW, Single and Three Phase · Maximum hydraulic module output temperature: 65°C · Works down to -20°C · Maximum 20 m rise between the outdoor unit and the hydraulic module Optional Controllers WH-UH09FE5 WH-UH12FE5 WH-UH09FE8 WH-UH12FE8 Aquarea Manager with LCD. PAW-HPM1 Kit Indoor unit Outdoor unit Heating capacity at +7°C (heating water at 35°C) COP at +7°C (heating water at 35°C) Heating capacity at +2°C (heating water at 35°C) COP at +2°C (heating water at 35°C) Heating capacity at -7°C (heating water at 35°C) COP at -7°C (heating water at 35°C) Heating capacity at +7°C (heating water at 65°C) COP at +7°C (heating water at 65°C) Heating capacity at +2°C (heating water at 65°C) COP at +2°C (heating water at 65°C) Heating capacity at -7°C (heating water at 65°C) COP at -7°C (heating water at 65°C) Indoor unit Dimensions / Weight HxWxD Water pipe connector Pump No. of Speed Input Power (Max.) Heating water flow (ΔT=5 K. 35°C) Capacity of integrated electric heater Input Power Running and Starting current Current 1 / Current 2 Recommended Fuse Recommended power cable section Outdoor unit Sound pressure level / Sound power level Dimensions / Weight HxWxD Pipe diameter Liquid / Gas Refrigerant (R407C) Pipe length range Pipe length for nominal capacity Pipe length for additional gas Additional gas amount (R407C) Elevation difference (in/out) Operation range Outdoor ambient Water outlet at -2/-7/-15 Internet Output water IO N AL 65 ºC OP T Control Ready INTERNET CONTROL HIGH TEMP HEAT PUMP High efficiency heating kW kW kW kW kW kW mm / kg Single Phase (Power to indoor) KIT-WHF09F3E5¹ WH-SHF09F3E5 WH-UH09FE5 9,00 4,64 9,00 3,45 9,00 2,74 9,00 2,25 9,00 1,88 8,90 1,64 892 x 502 x 353 / 46 R1¼ 7 Three Phase (Power to indoor) KIT-WHF09F3E8² WH-SHF09F3E8 WH-UH09FE8 9,00 4,64 9,00 3,45 9,00 2,74 9,00 2,25 9,00 1,88 8,90 1,64 KIT-WHF12F6E5¹ WH-SHF12F6E5 WH-UH12FE5 12,00 4,46 12,00 3,26 12,00 2,52 12,00 2,20 10,30 1,83 9,60 1,61 W l/min kW kW A A A mm² 25,8 3 1,94 9,3 28,5 / 26,0 30 / 30 4,0 / 4,0 892 x 502 x 353 / 47 892 x 502 x 353 / 47 R1¼ R1¼ 7 7 Min: 21 W at 10l/min / Max: 135 W at 53.8l/min 34,4 25,8 6 3 2,69 1,94 12,9 3,0 29,0 / 26,0 14,7 / 13,0 30 / 30 / 30 / 16 4,0 / 4,0 / 4,0 / 2,5 dB(A) / dB mm / kg mm (Inch) kg m m m g/m m °C °C 49 / 66 1.340 x 900 x 320 / 104 9,52 (3/8) / 15,88 (5/8) 2,90 3 – 30 7 10 70 20 -20 to 35 25 – 65 50 / 67 1.340 x 900 x 320 / 104 9,52 (3/8) / 15,88 (5/8) 2,90 3 – 30 7 10 70 20 -20 to 35 25 – 65 49 / 66 1.340 x 900 x 320 / 110 9,52 (3/8) / 15,88 (5/8) 2,90 3 – 30 7 10 70 20 -20 to 35 25 – 65 Easy Boiler Solar connection heating mode panels connection hot water refrigerant -20 ºC in control by BMS R407C OUTDOOR TEMPERATURE RETROFIT SOLAR KIT DHW CONNECTIVITY Environmentally friendly Down to Wireless LCD room thermostat with weekly timer. PAW-A2W-RTWIRELESS Aquarea Manager touch screen. PAW-HPMED for HPM Domestic 5 year compressor warranty KIT-WHF12F9E8² WH-SHF12F9E8 WH-UH12FE8 12,00 4,46 12,00 3,26 12,00 2,52 12,00 2,20 10,30 1,83 9,60 1,61 892 x 502 x 353 / 48 R1¼ 7 34,4 9 2,69 4,2 10,9 / 13,0 30 / 16 / 4,0 / 2,5 / 50 / 67 1.340 x 900 x 320 / 110 9,52 (3/8) / 15,88 (5/8) 2,90 3 – 30 7 10 70 20 -20 to 35 25 – 65 COP classification is at 230 V only in accordance with EU directive 2003/32/EC. Sound pressure measured at 1 m from the outdoor unit and at 1.5 m height. Performance in agreement with EN14511. 1) Available from March 2014. 2) Available from February 2014. INTERNET CONTROL READY: Optional. 47 NEW AQUAREA HIGH PERFORMANCE MONO-BLOC SINGLE PHASE HEATING ONLY - MDF HEATING AND COOLING - MDC DESIGN FOR LOW CONSUMPTION HOMES Panasonic has designed the new Aquarea Mono-Bloc heat pump for houses which have high performance requirements but limited space to install the outdoor unit. Whatever the weather, Aquarea can work even at -20°C. The Mono-Bloc is easy to install in new and existing residential properties. A class pump Technical focus · NEW! 5kW Model · NEW! New remote control functions · Efficient control of room temperature based on the outdoor temperature, indoor temperature using the Aquarea Manager. · Optional Smartphone control · Range from 6 to 9kW, Single Phase · Maximum hydraulic module output temperature: 55°C · Works down to -20°C · Plug and play system Optional Controllers NEW REMOTE CONTROL Only for the 5 kW Monobloc Aquarea Manager with LCD. PAW-HPM1 Heating capacity at +7°C (heating water at 35°C) COP at +7°C (heating water at 35°C) Heating capacity at +2°C (heating water at 35°C) COP at +2°C (heating water at 35°C) Heating capacity at -7°C (heating water at 35°C) COP at -7°C (heating water at 35°C) Cooling capacity at 35°C (cooling water at 7°C)¹ EER at 35°C (cooling water at 7°C)¹ Sound pressure level Sound power level Dimensions HxWxD Weight Water pipe connector Pump No. of Speed Input power (Min/Max.) Water Flow (ΔT=5 K. 35°C) Capacity of integrated electric heater Input Power at +7°C Running and Starting current at +7°C Recommended Fuse Recommended power cable section Operation range Outdoor ambient Water outlet at -2/-7/-15 kW kW kW kW dB(A) dB mm kg W l/min kW kW A A mm² °C °C Single Phase Heating Only WH-MDF06E3E5 6,00 4,48 5,00 3,45 5,15 2,68 – – 47 65 865 x 1283 x 320 112 R1¼ Variable Speed WH-MDF09E3E5 9,00 4,15 7,45 3,14 7,70 2,12 – – 49 67 865 x 1283 x 320 112 R1¼ Variable Speed 17,2 3,00 1,34 6,1 30 / 16 4,0 / 2,5 -20 to 35 20 – 55 25,8 3,00 2,17 9,9 30 / 16 4,0 / 2,5 -20 to 35 20 – 55 Aquarea Manager touch screen. PAW-HPMED for HPM Single Phase Heating and Cooling WH-MDC05F3E5 WH-MDC06E3E5 5,00 6,00 5,08 4,48 4,80 5,00 3,75 3,45 4,50 5,15 2,98 2,68 4,50 5,50 3,33 2,74 47 47 65 65 865 x 1.283 x 320 865 x 1.283 x 320 107 112 R1¼ R1¼ 7 Variable Speed Min: 21 W at 10l/min / Max: 135 W at 53.8l/min 9,2 17,2 3 3,00 0,985 1,34 3 6,1 30 / 15 30 / 16 4,0 / 2,5 4,0 / 2,5 -20 to 35 -20 to 35 20 – 55 20 – 55 COP classification is at 230 V only in accordance with EU directive 2003/32/EC. Sound pressure measured at 1 m from the outdoor unit and at 1.5 m height. Performance in agreement with EN14511. 1. Tentative. Authorized service partner or Authorized installer can enable the cooling mode through a special operation via the remote controller on site. 2. Tentative. 5.07 COP high efficiency IO OP T Control Ready N AL Internet INTERNET CONTROL AQUAREA HIGH PERFORMANCE INTERNET CONTROL READY: Optional. 48 Easy High Environmentally efficiency heating refrigerant heating mode control by BMS R410A OUTDOOR TEMPERATURE CONNECTIVITY friendly Down to -20 ºC in 5 year compressor warranty Wireless LCD room thermostat with weekly timer. PAW-A2W-RTWIRELESS WH-MDC09E3E5 9,00 4,15 7,45 3,14 7,70 2,12 7,00 2,44 49 67 865 x 1.283 x 320 112 R1¼ Variable Speed 25,8 3,00 2,17 9,9 30 / 16 4,0 / 2,5 -20 to 35 20 – 55 AQUAREA AQUAREA HIGH PERFORMANCE MONO-BLOC SINGLE PHASE / THREE PHASE HEATING AND COOLING - MDC The Aquarea MDC range adapts well in an existing installation with a boiler backup, and in a new application with underfloor heating, low temperature radiators or even fan-coil heaters. This range can also be connected to a solar kit in order to increase efficiency and minimize the impact on the ecosystem. Finally, it is possible to connect a thermostat for even better heating and cooling control and management. Technical focus · Efficient control of room temperature based on the outdoor temperature, indoor temperature using the Aquarea Manager. · Optional Smartphone control · Range from 9 to 16kW, Single and Three Phase · Maximum hydraulic module output temperature: 55°C · Works down to -20°C · Cooling temperature range 5–20°C Optional Controllers Aquarea Manager with LCD. PAW-HPM1 Heating capacity at +7°C (heating water at 35°C) COP at +7°C (heating water at 35°C) Heating capacity at +2°C (heating water at 35°C) COP at +2°C (heating water at 35°C) Heating capacity at -7°C (heating water at 35°C) COP at -7°C (heating water at 35°C) Cooling capacity at 35°C (cooling water at 7°C)¹ EER at 35°C (cooling water at 7°C)¹ Sound pressure level Sound power level Dimensions HxWxD Weight Water pipe connector Pump No. of Speed Input power (Max.) Heating water flow (ΔT=5 K. 35°C) Capacity of integrated electric heater Input Power Heating Cooling¹ Running and Starting current Heating Cooling¹ Current 1 Current 2 Current 3 Recommended Fuse Recommended power cable section Operation range Outdoor ambient Water outlet at -2/-7/-15 Heating / Cooling¹ kW kW kW kW dB(A) dB mm kg W l/min kW kW kW A A A A A A mm² °C °C Single Phase WH-MDC12C6E5 12,00 4,67 11,40 3,41 10,00 2,70 10,00 2,78 50 67 1.410 x 1.283 x 320 153 R1¼ 3 190 34,4 6 2,57 3,60 11,6 16,1 24,0 26,0 13,0 30 / 30 / 16 4,0 / 4,0 / 2,5 -20 to 35 25 – 55 / 5 – 20 Wireless LCD room thermostat with weekly timer. PAW-A2W-RTWIRELESS Aquarea Manager touch screen. PAW-HPMED for HPM WH-MDC14C6E5 14,00 4,50 12,40 3,32 10,70 2,68 11,50 2,61 51 68 1.410 x 1.283 x 320 153 R1¼ 3 190 40,1 6 3,11 4,40 14,1 19,7 25,0 26,0 13,0 30 / 30 / 16 4,0 / 4,0 / 2,5 -20 to 35 25 – 55 / 5 – 20 WH-MDC16C6E5 16,00 4,23 13,00 3,25 11,40 2,65 12,20 2,54 53 70 1.410 x 1.283 x 320 153 R1¼ 3 190 45,9 6 3,78 4,80 17,1 21,5 26,0 26,0 13,0 30 / 30 / 16 4,0 / 4,0 / 2,5 -20 to 35 25 – 55 / 5 – 20 Three Phase WH-MDC09C3E8 9,00 4,74 9,00 3,53 9,00 2,81 7,00 3,11 49 66 1.410 x 1.283 x 320 157 R1¼ 3 190 25,8 3 1,90 2,25 2,9 3,4 11,8 13,0 16 / 16 2,5 / 2,5 -20 to 35 25 – 55 / 5 – 20 WH-MDC12C9E8 12,00 4,67 11,40 3,41 10,00 2,70 10,00 2,78 50 67 1.410 x 1.283 x 320 157 R1¼ 3 190 34,4 9 2,57 3,60 3,9 5,3 8,8 13,0 13,0 16 / 16 / 16 2,5 / 2,5 / 2,5 -20 to 35 25 – 55 / 5 – 20 WH-MDC14C9E8 14,00 4,50 12,40 3,32 10,70 2,68 11,50 2,61 51 68 1.410 x 1.283 x 320 157 R1¼ 3 190 40,1 9 3,11 4,40 4,7 6,6 9,4 13,0 13,0 16 / 16 / 16 2,5 / 2,5 / 2,5 -20 to 35 25 – 55 / 5 – 20 WH-MDC16C9E8 16,00 4,23 13,00 3,25 11,40 2,65 12,20 2,54 53 70 1.410 x 1.283 x 320 157 R1¼ 3 190 45,9 9 3,78 4,80 5,7 7,2 9,9 13,0 13,0 16 / 16 / 16 2,5 / 2,5 / 2,5 -20 to 35 25 – 55 / 5 – 20 COP classification is at 230 V only in accordance with EU directive 2003/32/EC. Sound pressure measured at 1 m from the outdoor unit and at 1.5 m height. Performance in agreement with EN14511. 1. Specifications for Heating an Cooling models. 4.74 COP high efficiency IO OP T Control Ready N AL Internet INTERNET CONTROL AQUAREA HIGH PERFORMANCE High efficiency heating Easy Boiler Solar connection heating mode panels connection hot water refrigerant -20 ºC in control by BMS R410A OUTDOOR TEMPERATURE RETROFIT SOLAR KIT DHW CONNECTIVITY Environmentally friendly Down to Domestic 5 year compressor warranty INTERNET CONTROL READY: Optional. 49 AQUAREA T-CAP MONO-BLOC SINGLE PHASE / THREE PHASE HEATING AND COOLING - MXC The MXC is ideal for residential properties which don’t have an external boiler and require a maintained capacity level. T-CAP stands for Total Capacity. This new line-up is able to maintain the same nominal capacity even at -15°C without the help of an electrical booster heater. T-CAP is also able to provide extremely high efficiency, whatever the outside temperature or the water temperature. The MXC adapts well in an existing install with a boiler backup, and in a new application with underfloor heating, low temperature radiators or even fan-coil heaters. This range can also be connected to a solar kit in order to increase efficiency and minimize the impact on the ecosystem. Finally, it is possible to connect a thermostat for even better heating or cooling control and management. Technical focus · Efficient control of room temperature based on the outdoor temperature, indoor temperature using the Aquarea Manager. · Optional Smartphone control · Range from 9 to 12kW, Single and Three Phase · Maximum hydraulic module output temperature: 55°C · Works down to -20°C · Cooling temperature range 5–20°C Optional Controllers Aquarea Manager with LCD. PAW-HPM1 Heating capacity at +7°C (heating water at 35°C) COP at +7°C (heating water at 35°C) Heating capacity at +2°C (heating water at 35°C) COP at +2°C (heating water at 35°C) Heating capacity at -7°C (heating water at 35°C) COP at -7°C (heating water at 35°C) Cooling capacity at 35°C (cooling water at 7°C) EER at 35°C (cooling water at 7°C) Sound pressure level Sound power level Dimensions HxWxD Weight Water pipe connector Pump No. of Speed Input power (Max.) Heating water flow (ΔT=5 K. 35°C) Capacity of integrated electric heater Input Power Starting Current Current 1 Current 2 Current 3 Recommended Fuse Recommended power cable section Operation range Outdoor ambient Water outlet at -2/-7/-15 Heating / Cooling¹ kW kW kW kW dB(A) dB mm kg W l/min kW kW A A A A A mm² °C °C Single Phase WH-MXC09D3E5 9,00 4,74 9,00 3,53 9,00 2,81 7,00 3,11 49 66 14.10 x 1.283 x 320 155 R1¼ 3 190 25,8 3 1,90 10,4 25,0 26,0 Aquarea Manager touch screen. PAW-HPMED for HPM Three Phase WH-MXC09D3E8 9,00 4,74 9,00 3,53 9,00 2,81 7,00 3,11 49 66 1.410 x 1.283 x 320 158 R1¼ 3 190 25,8 3 1,90 2,9 14,7 13,0 WH-MXC12D6E5 12,00 4,67 12,00 3,40 12,00 2,70 10,00 2,78 50 67 1.410 x 1.283 x 320 155 R1¼ 3 190 34,4 6 2,57 16,7 29,0 26,0 13,0 30 / 30 / 16 4,0 / 4,0 / 2,5 -20 to 35 25 – 55 / 5 – 20 30 / 30 4,0 / 4,0 -20 to 35 25 – 55 / 5 – 20 16 / 16 2,5 / 2,5 -20 to 35 25 – 55 / 5 – 20 COP classification is at 230 V only in accordance with EU directive 2003/32/EC. Sound pressure measured at 1 m from the outdoor unit and at 1.5 m height. Performance in agreement with EN14511. 100% IO OP T Control Ready N AL Internet INTERNET CONTROL capacity at -15 ºC AQUAREA T-CAP INTERNET CONTROL READY: Optional. 50 High efficiency heating Easy Boiler Solar connection heating mode panels connection hot water refrigerant -20 ºC in control by BMS R410A OUTDOOR TEMPERATURE RETROFIT SOLAR KIT DHW CONNECTIVITY Environmentally friendly Down to Domestic 5 year compressor warranty Wireless LCD room thermostat with weekly timer. PAW-A2W-RTWIRELESS WH-MXC12D9E8 12,00 4,67 12,00 3,40 12,00 2,70 10,00 2,78 50 67 1.410 x 1.283 x 320 158 R1¼ 3 190 34,4 9 2,57 3,9 11,9 13,0 13,0 16 / 16 / 16 2,5 / 2,5 / 2,5 -20 to 35 25 – 55 / 5 – 20 AQUAREA AQUAREA HT MONO-BLOC SINGLE PHASE / THREE PHASE HEATING ONLY - MHF Aquarea HT is able to deliver 65°C with the Heat Pump alone. For a house with high temperature radiators (for example, cast iron radiators), the Aquarea High Temperature Solution is most suited as it provides output water temperatures of 65°C even at -20°C. Technical focus · Efficient control of room temperature based on the outdoor temperature, indoor temperature using the Aquarea Manager. · Optional Smartphone control · Range from 9 to 12kW, Single and Three Phase · Maximum hydraulic module output temperature: 65°C · Works down to -20°C Optional Controllers Aquarea Manager with LCD. PAW-HPM1 Heating capacity at +7°C (heating water at 35°C) COP at +7°C (heating water at 35°C) Heating capacity at +2°C (heating water at 35°C) COP at +2°C (heating water at 35°C) Heating capacity at -7°C (heating water at 35°C) COP at -7°C (heating water at 35°C) Heating capacity at +7°C (heating water at 65°C) COP at +7°C (heating water at 65°C) Heating capacity at +2°C (heating water at 65°C) COP at +2°C (heating water at 65°C) Heating capacity at -7°C (heating water at 65°C) COP at -7°C (heating water at 65°C) Sound pressure level Sound power level Dimensions HxWxD Weight Water pipe connector Pump No. of Speed Input Power (Max.) Heating water flow (ΔT=5 K. 35°C) Capacity of integrated electric heater Input Power Running and Starting current Current 1 Current 2 Current 3 Recommended Fuse Recommended power cable section Operation range Outdoor ambient Water outlet at -2/-7/-15 kW kW kW kW kW kW dB(A) dB mm kg W l/min kW kW A A A A A mm² °C °C Single Phase WH-MHF09D3E5 9,00 4,55 9,00 3,40 9,00 2,70 9,00 2,25 9,00 1,88 8,90 1,62 49 66 1.410 x 1.283 x 320 155 R1¼ 3 190 25,8 3 1,98 9,5 28,5 26,0 Aquarea Manager touch screen. PAW-HPMED for HPM Three Phase WH-MHF09D3E8 9,00 4,55 9,00 3,40 9,00 2,70 9,00 2,25 9,00 1,88 8,90 1,62 49 66 1.410 x 1.283 x 320 158 R1¼ 3 190 25,8 3 1,98 9,5 14,7 13,0 WH-MHF12D6E5 12,00 4,40 12,00 3,23 12,00 2,50 12,00 2,20 10,30 1,83 9,60 1,61 50 67 1.410 x 1.283 x 320 155 R1¼ 3 190 34,4 6 2,73 12,8 29,0 26,0 13,0 30 / 30 / 16 4,0 / 4,0 / 2,5 -20 to 35 25 – 65 30 / 30 4,0 / 4,0 -20 to 35 25 – 65 -16 / 16 2,5 / 2,5 -20 to 35 25 – 65 Wireless LCD room thermostat with weekly timer. PAW-A2W-RTWIRELESS WH-MHF12D9E8 12,00 4,40 12,00 3,23 12,00 2,50 12,00 2,20 10,30 1,83 9,60 1,61 50 67 1.410 x 1.283 x 320 158 R1¼ 3 190 34,4 9 2,73 12,8 11,9 13,0 13,0 16 / 16 / 16 2,5 / 2,5 / 2,5 -20 to 35 25 – 65 COP classification is at 230 V only in accordance with EU directive 2003/32/EC. Sound pressure measured at 1 m from the outdoor unit and at 1.5 m height. Performance in agreement with EN14511. Internet Output water IO N AL 65 ºC OP T Control Ready INTERNET CONTROL HIGH TEMP HEAT PUMP High efficiency heating Easy Boiler Solar connection heating mode panels connection hot water refrigerant -20 ºC in control by BMS R407C OUTDOOR TEMPERATURE RETROFIT SOLAR KIT DHW CONNECTIVITY Environmentally friendly Down to Domestic 5 year compressor warranty INTERNET CONTROL READY: Optional. 51 AQUAREA AIR RADIATORS WITH AQUAREA AIR The slimline Panasonic Aquarea Air radiators deliver high efficiency climate control. With a depth of just under 13 cm they are at the cutting edge of the market. Blending easily into the home, Aquarea Air’s elegant design and product refinements are clear to see in every detail. 2.0kW The Aquarea Air’s slimline profile has been achieved thanks to the innovative layout of the ventilation unit and the heat exchanger. The fan is tangential with asymmetric blades and the large surface heat exchanger enables high airflows to be achieved with low pressure loss and low noise levels. Exceptional ventilation efficiency means the motor uses considerably less energy (low wattage). The fan speed is continuously modulated by the temperature controller with proportional integral logic, with undoubted advantages for regulating the temperature and humidity in summer mode. WATER AT 35 °C NEEDED WITH STANDARD CAST RADIATORS All temperature curves and capacity are available on www.panasonicproclub.com 2.0kW WATER AT 65 °C NEEDED Fan Coils for Heat Pump application Without radiant heating Total heating capacity W Water flow kg/h Water pressure drop kPa Air flow m³/h Speed Maximum input power W Sound pressure level dB(A) Inlet water temperature °C Outlet water temperature °C Inlet air temperature °C Outlet air temperature °C Dimensions (H x W x D) mm Weight kg 3 ways valve included Touch screen thermostat PAW-AAIR-200 PAW-AAIR-200L 138 160 23,7 27,5 0,1 0,2 28 37 Main Fan Off Super Min 2 5 17,6 18,8 35 35 30 30 19 19 34,5 32,6 735 x 576 x 129 17 Yes Yes 217 37,3 0,4 55 Min 7 24,7 35 30 19 38,9 470 80,8 2,0 113 Med 9 33,2 35 30 19 32,0 570 98,0 2,9 162 Max 13 39,4 35 30 19 30,0 PAW-AAIR-700 PAW-AAIR-700L 223 360 38,4 61,9 0,1 0,1 44 84 Main Fan Off Super Min 3 9 18,4 19,6 35 35 30 30 19 19 34,9 32,4 935 x 579 x 129 20 Yes Yes 708 121,8 0,3 155 Min 14 25,8 35 30 19 33,3 1.032 177,5 0,8 252 Med 18 34,1 35 30 19 31,8 PAW-AAIR-900 PAW-AAIR-900L 273 475 47,0 81,7 0,1 0,2 54 110 Main Fan Off Super Min 3 11 18,4 22,3 35 35 30 30 19 19 34,8 32,5 1.135 x 579 x 129 23 Yes Yes 1.188 204,3 1,0 320 Max 22 40,2 35 30 19 30,6 Front panel with a radiant effect During winter, the operating principle is based on micro fans of very low power consumption and minimum noise that send hot air, coming from the heat exchanger, to the inside of the front panel of the device and therefore heat it effectively. With this principle, the terminal also provides significant power while heating, without running the main fan. Comfort temperatures are therefore maintained, without air movements and in silence. In summer mode, the airflow generated by the micro fans is stopped to avoid any dew formation on the terminal’s front surface. Radiant effect for better comfort Very silent and efficient DC fan motor Filter 52 Drain for cooling mode operation 886 152,4 0,5 248 Min 16 26,2 35 30 19 30,2 1.420 244,2 1,6 367 Med 20 34,4 35 30 19 31,1 DC fan motor for high efficiency 1.703 292,9 2,2 461 Max 24 42,2 35 30 19 30,6 NEW AQUAREA 32% MORE EFFICIENT THAN STANDARD RADIATORS PAW-AAIR-900 PAW-AAIR-700 PAW-AAIR-200 Main features · Front panel heating with radiant effect · High heating capacity (without main fan running) · 4 fan speeds and capacities · Exclusive design · Extremely compact (only 12.9 cm deep) · Cooling and dehumidification functions possible (drain is needed) · 3-way valve included (no overflow valve needed on the installation if more than 3 radiators installed) · Touch screen thermostat New line up of Super low temperature radiators for Heat Pump application: Aquarea Air 200/700/900 with radiating effect Major Benefit · On the water installation - Only 1 water temperature on the water circuit (35°C) - No expansive 2 zone kits - No overflow valve (as Aquarea Air has a 3-way valve) - Very easy to install · On the efficiency - COP with water at 35°C is 32% higher than efficiency with water at 45°C! (case MDF06, at +7°C) Accessories for Aquarea Air PAW-AAIR-LEGS-1 Kits of 2 legs to support the Aquarea Air on the floor and to protect the water pipings Operating on heating mode with radiator using only radiant effect A 129 579 659 Operating on heating mode with radiant effect and fan mode 200 735 A 700 935 900 1.135 Operating on cooling mode with fan A A B B A B Threaded supports Supports cover 53 Accessories Tanks Stainless Steel Tank Enamelled Tank Enamelled high efficiency Tank Model WH-TD20E3E5 WH-TD30E3E5-1 PAW-TE20E3STD PAW-TE30E3STD PAW-TE20E3HI PAW-TE30E3HI PAW-TE50E3HI Enamelled 2 coils Tank (for bivalent Solar + HP) PAW-TE30C2E3ESTD Water volume L 200 300 190 290 200 288 440 287 Maximum water temperature Dimensions Hight / Diameter Weight Electric heater Power supply Material inside tank Exchange surface °C mm kg kW V 75 1.150 / 580 49 3 230 Stainless steel 1,4 75 1.600 / 580 65 3 230 Stainless steel 1,8 95 1.432 / 540 65 3 230 Enamelled 1,90 95 1.794 / 600 85 3 230 Enamelled 2,55 95 1.804 / 600 78 3 230 Enamelled 2,25 95 1.294 / 700 139 3 230 Enamelled 3,20 95 1.921 / 700 222 3 230 Enamelled 6,20 95 1.294 / 700 145 3 230 1,9 Yes Yes ★★★★ ★★★★ ★★★★ 10 years No 2,3 Yes Yes ★★★★ ★★★★ ★★★★ 10 years No 1,6 Yes Yes ★★★★ ★★★★ ★★★★ 7 years Yearly 1,8 Yes Yes ★★★★ ★★★★ ★★★★ 7 years Yearly 1,2 Yes Yes ★★★★ ★★★★ ★★★★ 7 years Yearly 1,8 Yes Yes ★★★★ ★★★★ ★★★★ 7 years Yearly 2,4 Yes Yes ★★★★ ★★★★ ★★★★ 7 years Yearly m² Energy loss at 65°C¹ kWh/24h 3 Way valve included 20 m temperature sensor cable included Heat up time Valuation Energy losses Valuation Efficiency of the tank Valuation Warranty Maintenance required 2,4 (for HP) +1,1 (for solar or boiler) 2,7 Yes Yes ★★★★ ★★★★ ★★★★ 7 years Yearly High efficiency water tanks with a large exchange surface and high levels of insulation to minimise energy losses. 1) Insulated tested under EN12897. Aquarea Tank. Tanks and buffer tank in one! Tanks and buffer tank in one! Model Water volume L Maximum water temperature °C Dimension HxWxD mm Weight kg Electric heater kW Power supply V Material inside tank Exchange surface m² Energy loss at 65°C¹ kWh/24h A class pump Number of speed Pressure drop (Min / Max) kPa Input power (Min / Max) W 3 Way valve included Safety thermostat with contact for failure part of E-Heating Location of the electrical heater Electrical backup heater on the buffer tank CZ-NS1P // CZ-NS3P // CZ-NS2P CZ-TK1 Solar Kit Accessories CZ-NS1P PCB for solar connection kit for split systems CZ-NS2P PCB for solar connection kit for monoblock systems CZ-NS3P PCB for solar connection kit for monoblock systems 6 & 9 kW 54 PAW-TS1 / PAW-TS2 Sanitary Tank Accessories CZ-TK1 Temperature sensor kit for third party tank (with copper pocket and 6 m length sensor cable) PAW-TS1 Tank sensor with 6 meter cable length PAW-TS2 Tank sensor with 6 meter cable length Standard Sanitary PAW-TD20B8E3-NDS 185 (for DHW tank) / 80 (for buffer tank) 100 1.810 x 600 x 632 150 3 230 - 2p Stainless steel 2,3 1,3 Stepless (800-4250 rpm) 5/6 3 / 45 Yes Yes Mid Optional CZ-NE1P Deice Accessories CZ-NE1P Base pan heater (for all old Bi-Block and Mono Block, not for the 3 and 5 kW) CZ-NE2P Base pan heater (for 3 kW and 5 kW) CZ-NE3P Base pan heater (for all new F generation products: F3, F6, F9) Connectivity Solutions Model name Interface PAW-AW-KNX-1i KNX Interface PAW-ZIG-A2W Interface to connect to Zig Bee PAW-AW-MBS-1 Modbus Interface PAW-AW-WIFI-1A IntesisHome for web control PAW-AW-WIFI-1TE Wired room temperature sensor (only for PAW-AW-WIFI-1A) NEW PAW-HPM1 Aquarea Manager Kits PAW-HPM12ZONE-U PAW-HPM12ZONE-M PAW-HPM12ZONELCD-U PAW-HPM12ZONELCD-M PAW-HPM12ZONE-F PAW-HPM12ZONELCD-F AQUAREA PAW-HPM2 HPM with roomsensor and setpoint adaption for Bi-bloc + sensors HPM with roomsensor and setpoint adaption for Mono-bloc + sensors HPM with LCD Wireless Room Thermostat for Bi-bloc + sensors HPM with LCD Wireless Room Thermostat for Mono-bloc + sensors HPM with roomsensor and setpoint adaption for Mono-bloc + Bi-bloc F type + sensor HPM with LCD Wireless Room Thermostat for Mono-bloc + Bi-bloc F type + sensor PAW-HPMED Aquarea Manager Accessories PAW-HPM1 PAW-HPM2 PAW-HPMINT-U PAW-HPMINT-M PAW-HP-MINT-F PAW-HPMB1 PAW-HPMDHW PAW-HPMSOL1 PAW-HPMAH1 PAW-HPMR4 PAW-HPMED PAW-HPMLCD PAW-LANCABLE PAW-A2WSWITCH PAW-HPM-CASE PAW-DEWPOINTSENSOR PAW-HPMUH Aquarea Manager with LCD Aquarea Manager without LCD Interface to connect Aquarea Manager to Heat pump Aquarea Bi-Bloc, with inverter control C and D types Interface to connect Aquarea Manager to Heat pump Aquarea Mono-Bloc, with inverter control Interface to connect Aquarea Manager to Heat pump Aquarea Bi-Bloc F type Buffer tank sensor Buffer tank sensor with well Buffer tank sensor solar (with higher temperature range) Water flow pipe sensor for heating circuit Room sensor + set point adaption Touch screen Room thermostast with LCD Network cable Network switch HPM casing with Premounted cables NEW! Dew point sensor Outdoor temperature sensor Hydraulic Accessories PAW-2PMP2ZONE PAW-FILTER PAW-FILTER-ONLY 2 zone kit, hydraulic switch, manifold, 2 A-class pumps, 1 mixture valve and check valve + filter 2 check valves + filter with 1" Filter with 1" PAW-A2W-RTWIRED PAW-A2W-RTWIRELESS Room Thermostats PAW-A2W-RTWIRED PAW-A2W-RTWIRELESS Wired LCD room thermostat with weekly timer Wireless LCD room thermostat with weekly timer Accessories For All In One 2014 PAW-FP-WMP-1 Flexible pipings and wall mounting plate for all in one (Available from October 2014) 55 Examples of installations with Aquarea Manager Temperature control in the 2 zones with PAW-HPM12ZONE-U 2 heat pumps in cascade with the PAWHPM12ZONELCD-U 2 heat pump + boiler with PAWHPM12ZONE-U 56 AQUAREA Temperature control in zones 2 + ECS with PAW-HPM12ZONE-U Management of heat pump + boiler and DHW with PAW-HPM12ZONELCD-U 3 heat pumps in cascade with PAWHPM12ZONELCD-U 57 A typical example of savings and efficiencies that Aquarea can offer to you A 125m2 house in Reims The example below shows a typical 3 bedroom French home and highlights the potential savings that can be achieved with Panasonic's Aquarea heat pump.* Building data Address Building area Standard heating requirement Internal gains Solar gains (windows) Indoor design temperature Outdoor temp. limit for heating 'on' Heat distribution Max. flow water temperature Max. return water temperature Solar collector area Reims (French) 125 m2 11,3 kW 5625 kWh/year 4500 kWh/year 20 °C 15 °C Underfloor heating by 100 % Radiator heating by -- % Wall heating by -- % 55 °C 50 °C -- m2 Rate data Service hot water Type of service Hot water with heat pump Description Tank volume 300 Litre Shut off times total 0.0 h/day Average daily need 200 Litre Weekends with shut off times yes Cold water inlet temperature 10 °C Daytime rate of heat pump Time for daytime rate Target tank temperature 50 °C Exchange loss 5K Nighttime rate of heat pump Time for nighttime rate Electrical auxiliary heating necessary no 5 - 19 o'clock 14,0 pence/kWh 19 - 5 o'clock 14,0 pence/kWh like heat pump: yes -- pence/kWh Heating element for monoenergetic operation Like heat pump: yes -- pence/kWh Heating element for post heating of hot water like heat pump: yes -- pence/kWh Heat circulation pump(s) Used Panasonic heat pump French (Panasonic) Description WH-SXF12D6E5 Sanitary tank WH-TD30E3E5 Heat pump type air / water Climatic data Wattage at 2/35 heat: 11,7 kW, electric: 3,4 kW Climatic location Recommended flow-through of air 4800,0 m3/h Monthly average temperatures in °C Jan 3,4 Jul 16,0 Max. flow temperature 55 °C Feb 3,6 Aug 15,9 Mode of operation monovalent Mar 5,7 Sep 13,7 Design/Bivalent temperature -5,0 °C Apr 8,0 Oct 10,4 Number of heat pumps used 1 May 11,2 Nov 6,7 Wattage of fan (included in heat pump performance data: yes) 60 W Jun 14,1 Dec 4,6 Wattage of heat circulation pump(s) 180 W * Calculations were carried using Panasonic's Aquarea Designer software, available from the PRO Club website (www.panasonicproclub.com). 58 Reims (FR) AQUAREA Calculation results Monthly heat consumption in kWh Annual energy costs Caused by heat producers Heat pump 1.600 € Hot water heating rod 0€ Caused by heat consumers Space heating 1.220 € Service hot water 225 € Heat circulation pump(s) 155 € Total 4500 4000 3500 3000 kWh 2500 2000 1500 1000 500 0 Jan 1.600 € Feb Mar Apr May Jun jul Aug Oct Nov Dec Hot water Heating Aquarea energy coverage Sep 12 10 8 kW Enviroment energy 6 4 Drive energy 2 0 -5 -1 3 7 11 Outdoor temperature (°C) Additional energy Comparison of running costs Operational costs Type of heating Price in pence/kWh Efficiency [%] Additional Total costs costs in €/year in €/year Heat pump - - 0 1.600 Oil 6,5 85 0 3.050 Gas 4,0 90 0 1.868 Wood heating 5,0 80 0 2.539 Electric night storage heater 12,0 100 0 4.455 Electric heating element 100 0 5.197 14,0 4500 4000 3500 kW 3000 2500 2000 1500 1000 500 0 Aquarea Heat pump Comparison of CO2 emissions 18000 16000 14000 12000 kg/year 10000 8000 6000 4000 2000 0 Oil Gas Wood heating Night heater Electr. Direct Comparison of CO2 savings 12000 10000 8000 kg/year 6000 4000 2000 0 Aquarea Heat pump Oil Oil Gas Night heater Gas Night heater Electr. Direct Electr. Direct 59 Heating capacity table based on outlet temperature and outside temperature Heating capacity Curve Aquarea. High Performance. Bi-Bloc Single Phase. Heating Only - SDF. Heating and Cooling - SDC. 3 and 5kW WH-SDF03E3E5 / WH-SDC03E3E5 Tamb HC IP COP HC IP COP HC IP COP LWC 30 30 30 35 35 35 40 40 40 3,20 1,39 2,30 3,20 1,39 2,30 3,00 1,64 1,83 -15 3,20 1,19 2,69 3,20 1,19 2,69 3,20 1,48 2,16 -7 3,20 0,90 3,56 3,20 0,90 3,56 3,20 1,16 2,76 2 3,20 0,64 5,00 3,20 0,64 5,00 3,20 0,89 3,60 7 HC 45 3,00 3,20 3,20 3,20 IP 45 1,64 1,48 1,16 0,89 COP 45 1,83 2,16 2,76 3,60 HC 50 2,75 3,20 3,20 3,20 IP 50 1,92 1,86 1,49 1,20 COP 50 1,43 1,72 2,15 2,67 HC 55 2,75 3,20 3,20 3,20 IP 55 1,92 1,86 1,49 1,20 COP 55 1,43 1,72 2,15 2,67 WH-SDF05E3E5 / WH-SDC05E3E5 Tamb HC IP LWC 30 30 4,20 1,94 -15 4,20 1,62 -7 4,20 1,35 2 5,00 1,08 7 HC 45 3,40 3,80 4,20 5,00 IP 45 1,98 1,82 1,65 1,48 COP 45 1,72 2,09 2,55 3,38 HC 50 3,00 3,55 4,10 5,00 IP 50 2,12 2,08 2,07 1,89 COP 50 1,42 1,71 1,98 2,65 HC 55 3,00 3,55 4,10 5,00 IP 55 2,12 2,08 2,07 1,89 COP 55 1,42 1,71 1,98 2,65 COP 30 2,16 2,59 3,11 4,63 HC 35 4,20 4,20 4,20 5,00 IP 35 1,94 1,62 1,35 1,08 COP 35 2,16 2,59 3,11 4,63 HC 40 3,4 3,8 4,2 5,00 IP 40 1,98 1,82 1,65 1,48 COP 40 1,72 2,09 2,55 3,38 Cooling Capacity Curve Aquarea. High Performance. Bi-Bloc Single Phase. Heating and Cooling - SDC. 3 and 5kW MODELS WH-SDC03E3E5 Tamb CC IP CC IP CC LWC 7 7 14 14 18 2,40 0,42 4,40 0,73 3,70 18 3,20 0,73 4,10 0,86 3,50 25 3,20 1,04 3,90 1,07 3,30 35 2,90 1,20 3,50 1,20 3,00 43 WH-SDC05E3E5 CC IP 7 7 4,50 0,89 5,00 1,43 4,50 1,67 3,30 1,53 IP 18 0,49 0,59 0,74 0,88 CC 14 5,00 6,30 5,50 4,10 IP 14 0,90 1,50 1,68 1,52 CC 18 5,70 5,40 5,00 4,40 IP 18 0,90 1,06 1,33 1,53 Tamb: Ambient Temperature (°C). LWC: Leaving Water Condenser Temperature (°C). HC: Heating capacity (kW). CC: Cooling Capacity (kW). IP: Power Input (kW) This data is measured by Panasonic in accordance with EN14511-2 standard. This data is for reference purpose only, and does not guarantee the performance. Hydraulic Pump Performance. Constant Pressure Head Difference ( p-c). 3 and 5kW Hydraulic Pump Performance. Variable Pressure Head Difference ( p-v). 3 and 5kW WH-SDF03E3E5 // WH-SDF05E3E5 // WH-SDC03E3E5 // WH-SDC05E3E5 WH-SDF03E3E5 // WH-SDF05E3E5 // WH-SDC03E3E5 // WH-SDC05E3E5 40 6&7 60 5 50 4 40 3 30 2 20 1 External Static Pressure (kPa) External Static Pressure (kPa) 70 6 30 5 4 20 3 2 10 10 0 0 10 20 30 Water Flow Rate (L/min) A p-c When pressure loss of system increased, pump speed will be reduced for maintain constant pressure. 60 40 0 0 10 20 30 Water Flow Rate (L/min) A p-v When pressure loss of system increased, pump speed will be reduced for maintain pressure according to water flow rate. AQUAREA Heating capacity Curve Aquarea. High Performance. Mono-Bloc Single Phase. Heating Only - MDF. Heating and Cooling - MDC. 5, 6 and 9kW WH-MDC05F3E5 Tamb HC IP COP HC IP COP HC IP COP HC LWC 30 30 30 35 35 35 40 40 40 45 1,82 2,75 5,00 1,95 2,56 5,00 2,20 2,27 5,00 5,00 -15 4,50 1,44 3,13 4,50 1,51 2,98 4,50 1,64 2,74 4,50 -7 4,80 1,22 3,93 4,80 1,28 3,75 4,80 1,40 3,43 4,50 2 5,00 0,91 5,49 5,00 0,99 5,08 5,00 1,13 4,42 5,00 7 5,00 0,67 7,46 5,00 0,71 7,04 5,00 0,78 6,41 5,00 25 IP 45 2,45 1,78 1,52 1,26 0,86 COP 45 2,04 2,53 2,96 3,97 5,81 HC 50 5,00 4,50 4,30 5,00 5,00 IP 50 2,70 1,94 1,57 1,44 0,98 COP 50 1,85 2,32 2,14 3,47 5,10 HC 55 5,00 4,30 4,00 5,00 5,00 IP 55 2,95 2,12 1,72 1,63 1,10 COP 55 1,69 2,03 2,33 3,07 4,55 WH-MDF06E3E5 / WH-MDC06E3E5 Tamb HC IP COP LWC 30 30 30 2,50 2,46 6,15 -15 5,18 1,68 3,09 -7 5,00 1,23 4,08 2 6,00 1,13 5,33 7 7,30 0,78 9,42 25 HC 35 5,90 5,15 5,00 6,00 7,10 IP 35 2,66 1,92 1,45 1,35 0,93 COP 35 2,22 2,68 3,45 4,46 7,63 HC 40 5,65 5,13 5,00 6,00 6,90 IP 40 2,82 2,17 1,68 1,58 1,09 COP 40 2,00 2,37 2,99 3,81 6,36 HC 45 5,40 5,10 5,00 6,00 6,70 IP 45 2,98 2,41 1,90 1,80 1,24 COP 45 1,81 2,12 2,63 3,33 5,40 HC 50 5,20 5,45 5,00 6,00 6,50 IP 50 3,15 2,81 2,19 2,09 1,41 COP 50 1,65 1,94 2,28 2,87 4,61 HC 55 5,00 5,80 5,00 6,00 6,30 IP 55 3,32 3,20 2,48 2,38 1,58 COP 55 1,51 1,81 2,02 2,52 3,99 WH-MDF09E3E5 / WH-MDC09E3E5 Tamb HC IP COP LWC 30 30 30 7,90 3,62 2,19 -15 7,80 3,38 2,31 -7 7,00 2,01 3,49 2 9,00 1,87 4,83 7 9,00 0,99 9,09 25 HC 35 7,60 7,70 2,45 9,00 9,00 IP 35 3,77 3,63 2,37 2,17 1,31 COP 35 2,02 2,12 3,14 4,16 6,87 HC 40 7,30 7,60 7,00 9,00 9,00 IP 40 3,93 3,88 2,60 2,48 1,63 COP 40 1,86 1,96 2,70 3,64 5,52 HC 45 7,00 7,50 7,00 9,00 9,00 IP 45 4,08 4,13 2,89 2,78 1,95 COP 45 1,72 1,82 2,42 3,24 4,62 HC 50 6,45 7,55 7,00 8,95 9,00 IP 50 4,06 4,59 3,37 3,31 2,20 COP 50 1,59 1,64 2,08 2,70 4,09 HC 55 5,90 7,60 7,00 8,90 9,00 IP 55 4,03 5,05 3,85 3,84 2,45 COP 55 1,46 1,50 1,82 2,32 3,67 Aquarea. High Performance. Mono-Bloc Single Phase. Heating and Cooling - MDC. 5, 6 and 9kW MODELS WH-MDC05F3E5 WH-MDC06E3E5 Tamb CC IP CC IP CC IP CC IP LWC 7 7 14 14 18 18 7 7 1,95 0,45 2,20 0, 45 2,45 0,50 4,64 0,91 18 5,00 1,25 6,30 1,20 6,30 0,80 5,85 1,43 25 4,50 1,35 5,10 1,50 5,00 1,00 5,50 2,03 35 3,75 1,75 4,50 1,80 4,25 1,20 4,56 2,34 43 CC 14 5,83 9,55 6,70 6,31 IP 14 0,99 1,73 2,06 2,47 CC 18 6,74 9,81 7,30 7,14 IP 18 0,94 1,68 2,05 2,45 WH-MDC09E3E5 CC IP 7 7 5,36 1,05 6,44 1,85 7,00 2,90 5,32 3,18 CC 14 6,12 10,50 8,40 6,34 IP 14 1,08 2,51 2,95 2,48 CC 18 7,02 11,16 9,00 6,78 IP 18 1,08 2,52 3,00 2,46 Cooling Capacity Curve Tamb: Ambient Temperature (°C). LWC: Leaving Water Condenser Temperature (°C). HC: Heating capacity (kW). CC: Cooling Capacity (kW). IP: Power Input (kW) This data is measured by Panasonic in accordance with EN14511-2 standard. This data is for reference purpose only, and does not guarantee the performance. Hydraulic pump performance of the F type Heat Pumps: A class pump F (5 kW and 16 kW) 110 100 90 80 70 60 50 40 30 20 10 0 7 6 5 4 Power consumption (W) External Static Pressure (kPa) Hydraulic pump performance of the F type Heat Pumps: A class pump F (5 kW and 16 kW) 3 2 1 0 10 Min 20 30 Water Flow Rate (L/min) Pump Speed 1 Pump Speed 2 40 200 190 180 170 160 150 140 130 120 110 100 90 80 70 60 50 40 30 20 10 0 7 4 3 1 0 50 10 20 Pump Speed 3 Pump Speed 4 Pump Speed 5 30 Pump Speed 6 WH-MDC06E3E5 External Static Pressure (kPa) External Static Pressure (kPa) 4 40 3 30 2 20 1 50 60 70 Max WH-MDC06E3E5 5 50 40 Hydraulic Pump Performance. Variable Pressure Head Difference (Δp-c) 6&7 60 2 Water Flow Rate (L/min) Hydraulic Pump Performance. Constant Pressure Head Difference (Δp-c) 70 5 6 40 6 30 5 4 20 3 2 10 10 0 0 10 20 30 Water Flow Rate (L/min) A Δp-c When pressure loss of system increased, pump speed will be reduced for maintain constant pressure. 40 0 0 10 20 30 Water Flow Rate (L/min) A Δp-c When pressure loss of system increased, pump speed will be reduced for maintain pressure according to water flow rate. 61 Heating capacity table based on outlet temperature and outside temperature Heating capacity Curve Aquarea. High Performance. Bi-Bloc Single Phase / Three Phase. Heating and Cooling. SDC WH-SDC07F3E5 Tamb HC IP COP HC IP COP HC LWC 30 30 30 35 35 35 40 4,60 1,85 2,49 4,60 1,98 2,32 4,60 -15 5,15 1,78 2,89 5,15 1,92 2,68 5,08 -7 6,70 1,81 3,70 6,55 1,96 3,34 6,58 2 7,00 1,41 4,96 7,00 1,57 4,46 7,00 7 7,00 0,77 9,09 7,00 0,91 7,69 6,40 25 IP 40 2,17 2,12 2,27 1,75 1,01 COP 40 2,12 2,40 2,90 4,00 6,34 HC 45 4,60 5,00 6,60 7,00 6,10 IP 45 2,40 2,36 2,62 2,10 1,15 COP 45 1,92 2,12 2,52 3,33 5,30 HC 50 4,55 4,90 6,30 6,90 5,90 IP 50 2,66 2,45 2,88 2,28 1,31 COP 50 1,71 2,00 2,19 3,03 4,50 HC 55 4,50 4,80 6,00 6,80 5,70 IP 55 2,98 2,65 3,14 2,70 1,47 COP 55 1,51 1,81 1,91 2,52 3,88 WH-SDC09F3E5 Tamb HC LWC 30 6,00 -15 6,10 -7 6,80 2 9,00 7 9,00 25 IP 30 2,53 2,14 1,85 1,91 1,05 COP 30 2,37 2,85 3,68 4,71 8,57 HC 35 5,90 5,90 6,70 9,00 9,00 IP 35 2,66 2,34 2,14 2,18 1,25 COP 35 2,22 2,52 3,13 4,13 7,20 HC 40 5,50 5,85 6,70 9,00 8,40 IP 40 2,80 2,61 2,36 2,43 1,38 COP 40 1,96 2,24 2,84 3,70 6,09 HC 45 5,40 5,80 6,60 9,00 8,00 IP 45 2,98 2,88 2,62 2,79 1,57 COP 45 1,81 2,01 2,52 3,23 5,10 HC 50 5,20 5,80 6,30 8,95 7,80 IP 50 3,12 3,04 2,88 3,21 1,79 COP 50 1,67 1,91 2,19 2,79 4,36 HC 55 5,00 5,80 6,00 8,90 7,50 IP 55 3,31 3,21 3,14 3,85 2,01 COP 55 1,51 1,81 1,91 2,31 3,73 WH-SDC12F6E5 Tamb HC LWC 30 9,30 -15 10,40 -7 11,80 2 12,00 7 12,00 25 IP 30 3,46 3,37 3,10 2,10 1,38 COP 30 2,69 3,09 3,81 5,71 8,70 HC 35 8,90 10,00 11,40 12,00 12,00 IP 35 3,62 3,66 3,31 2,53 1,66 COP 35 2,46 2,73 3,44 4,74 7,23 HC 40 8,50 9,60 11,00 12,00 11,80 IP 40 3,79 3,86 3,53 2,96 1,94 COP 40 2,24 2,49 3,12 4,05 6,08 HC 45 8,10 9,20 10,60 12,00 11,70 IP 45 3,95 4,06 3,74 3,39 2,23 COP 45 2,05 2,27 2,83 3,54 5,25 HC 50 7,50 8,70 9,80 12,00 11,50 IP 50 4,05 4,16 3,94 3,78 2,49 COP 50 1,85 2,09 2,49 3,17 4,62 HC 55 7,00 8,20 9,10 12,00 11,40 IP 55 4,16 4,27 4,14 4,16 2,74 COP 55 1,68 1,92 2,20 2,88 4,16 WH-SDC14F6E5 Tamb HC LWC 30 9,90 -15 11,10 -7 12,90 2 14,00 7 14,00 25 IP 30 3,87 3,69 3,47 2,56 1,71 COP 30 2,56 3,01 3,72 5,47 8,19 HC 35 9,50 10,70 12,40 14,00 14,00 IP 35 4,01 3,96 3,69 3,07 2,06 COP 35 2,37 2,70 3,36 4,56 6,80 HC 40 9,00 10,20 11,90 14,00 14,00 IP 40 4,15 4,16 3,91 3,59 2,41 COP 40 2,17 2,45 3,04 3,90 5,81 HC 45 8,60 9,80 11,40 14,00 14,00 IP 45 4,29 4,36 4,13 4,10 2,76 COP 45 2,00 2,25 2,76 3,41 5,07 HC 50 7,90 9,10 10,40 13,60 14,00 IP 50 4,41 4,53 4,25 4,57 3,01 COP 50 1,79 2,01 2,45 2,98 4,65 HC 55 7,30 8,50 9,50 13,30 14,00 IP 55 4,52 4,70 4,36 5,04 3,40 COP 55 1,62 1,81 2,18 2,64 4,12 WH-SDC16F6E5 Tamb HC LWC 30 10,60 -15 11,90 -7 13,50 2 16,00 7 16,00 25 IP 30 4,09 4,03 3,74 3,21 2,31 COP 30 2,59 2,95 3,61 4,98 6,93 HC 35 10,30 11,40 13,00 16,00 16,00 IP 35 4,38 4,26 3,96 3,74 2,69 COP 35 2,35 2,68 3,28 4,28 5,95 HC 40 10,00 10,80 12,40 16,00 16,00 IP 40 4,67 4,46 4,18 4,27 3,07 COP 40 2,14 2,42 2,97 3,75 5,21 HC 45 9,70 10,30 11,90 16,00 16,00 IP 45 4,96 4,66 4,40 4,80 3,45 COP 45 1,96 2,21 2,70 3,33 4,64 HC 50 8,80 9,60 10,80 15,20 16,00 IP 50 4,94 4,81 4,46 5,11 3,67 COP 50 1,78 2,00 2,42 2,97 4,36 HC 55 7,90 9,00 9,80 14,50 15,90 IP 55 4,91 4,95 4,51 5,41 3,89 COP 55 1,61 1,82 2,17 2,68 4,09 WH-SDC09F3E8 Tamb HC LWC 30 8,65 -15 9,35 -7 9,31 2 9,00 7 9,00 25 IP 30 3,06 2,91 2,35 1,54 1,05 COP 30 2,83 3,21 3,96 5,84 8,57 HC 35 8,30 9,00 9,00 9,00 9,00 IP 35 3,21 3,16 2,51 1,86 1,24 COP 35 2,59 2,85 3,59 4,84 7,26 HC 40 7,95 8,85 9,00 9,00 8,73 IP 40 3,41 3,46 2,78 2,16 1,44 COP 40 2,33 2,56 3,24 4,17 6,06 HC 45 7,60 8,70 9,00 9,00 8,46 IP 45 3,61 3,76 3,05 2,46 1,64 COP 45 2,11 2,31 2,95 3,66 5,16 HC 50 7,15 8,30 8,90 9,00 8,28 IP 50 3,71 3,81 3,49 2,76 1,82 COP 50 1,93 2,18 2,55 3,26 4,55 HC 55 6,70 7,90 8,80 9,00 8,10 IP 55 3,81 3,86 3,94 3,06 2,00 COP 55 1,76 2,05 2,23 2,94 4,05 WH-SDC12F9E8 Tamb HC LWC 30 9,30 -15 10,40 -7 11,80 2 12,00 7 12,00 25 IP 30 3,46 3,37 3,10 2,10 1,38 COP 30 2,69 3,09 3,81 5,71 8,70 HC 35 8,90 10,00 11,40 12,00 12,00 IP 35 3,62 3,66 3,31 2,53 1,66 COP 35 2,46 2,73 3,44 4,74 7,23 HC 40 8,50 9,60 11,00 12,00 11,80 IP 40 3,79 3,86 3,53 2,96 1,94 COP 40 2,24 2,49 3,12 4,05 6,08 HC 45 8,10 9,20 10,60 12,00 11,70 IP 45 3,95 4,06 3,74 3,39 2,23 COP 45 2,05 2,27 2,83 3,54 5,25 HC 50 7,50 8,70 9,80 12,00 11,50 IP 50 4,05 4,16 3,94 3,78 2,49 COP 50 1,85 2,09 2,49 3,17 4,62 HC 55 7,00 8,20 9,10 12,00 11,40 IP 55 4,16 4,27 4,14 4,16 2,74 COP 55 1,68 1,92 2,20 2,88 4,16 WH-SDC14F9E8 Tamb HC LWC 30 9,90 -15 11,10 -7 12,90 2 14,00 7 14,00 25 IP 30 3,87 3,69 3,47 2,56 1,71 COP 30 2,56 3,01 3,72 5,47 8,19 HC 35 9,50 10,70 12,40 14,00 14,00 IP 35 4,01 3,96 3,69 3,07 2,06 COP 35 2,37 2,70 3,36 4,56 6,80 HC 40 9,00 10,20 11,90 14,00 14,00 IP 40 4,15 4,16 3,91 3,59 2,41 COP 40 2,17 2,45 3,04 3,90 5,81 HC 45 8,60 9,80 11,40 14,00 14,00 IP 45 4,29 4,36 4,13 4,10 2,76 COP 45 2,00 2,25 2,76 3,41 5,07 HC 50 7,90 9,10 10,40 13,60 14,00 IP 50 4,41 4,53 4,25 4,57 3,01 COP 50 1,79 2,01 2,45 2,98 4,65 HC 55 7,30 8,50 9,50 13,30 14,00 IP 55 4,52 4,70 4,36 5,04 3,40 COP 55 1,62 1,81 2,18 2,64 4,12 WH-SDC16F9E8 Tamb HC LWC 30 10,60 -15 11,90 -7 13,50 2 16,00 7 16,00 25 IP 30 4,09 4,03 3,74 3,21 2,31 COP 30 2,59 2,95 3,61 4,98 6,93 HC 35 10,30 11,40 13,00 16,00 16,00 IP 35 4,38 4,26 3,96 3,74 2,69 COP 35 2,35 2,68 3,28 4,28 5,95 HC 40 10,00 10,80 12,40 16,00 16,00 IP 40 4,67 4,46 4,18 4,27 3,07 COP 40 2,14 2,42 2,97 3,75 5,21 HC 45 9,70 10,30 11,90 16,00 16,00 IP 45 4,96 4,66 4,40 4,80 3,45 COP 45 1,96 2,21 2,70 3,33 4,64 HC 50 8,80 9,60 10,80 15,20 16,00 IP 50 4,94 4,81 4,46 5,11 3,67 COP 50 1,78 2,00 2,42 2,97 4,36 HC 55 7,90 9,00 9,80 14,50 15,90 IP 55 4,91 4,95 4,51 5,41 3,89 COP 55 1,61 1,82 2,17 2,68 4,09 62 AQUAREA Cooling Capacity Curve Aquarea. High Performance. Bi-Bloc Single Phase / Three Phase. Heating and Cooling. SDC MODELS WH-SDC07F3E5 WH-SDC09F3E5 WH-SDC12F6E5 WH-SDC14F6E5 Tamb CC IP CC IP CC IP CC IP LWC 7 7 7 7 7 7 7 7 5,09 0,86 5,93 1,05 7,65 1,26 8,85 1,46 16 6,58 1,73 7,79 2,23 9,20 2,26 10,00 2,64 25 6,00 2,28 7,00 2,88 10,00 3,56 11,50 4,36 35 5,14 2,67 6,20 3,26 7,60 3,91 9,05 4,97 43 WH-SDC16F6E5 CC IP 7 7 9,62 1,59 10,51 2,81 12,20 4,76 10,08 5,43 WH-SDC09F3E8 CC IP 7 7 5,90 0,97 7,45 1,55 7,00 2,21 5,80 2,55 WH-SDC12F9E8 CC IP 7 7 7,65 1,26 9,20 2,26 10,00 3,56 7,60 3,91 WH-SDC14F9E8 CC IP 7 7 8,85 1,46 10,00 2,64 11,50 4,36 9,05 4,97 WH-SDC16F9E8 CC IP 7 7 9,62 1,59 10,51 2,81 12,20 4,76 10,08 5,43 Tamb: Ambient Temperature (°C). LWC: Leaving Water Condenser Temperature (°C). HC: Heating capacity (kW). CC: Cooling Capacity (kW). IP: Power Input (kW) This data is measured by Panasonic in accordance with EN14511-2 standard. This data is for reference purpose only, and does not guarantee the performance. 110 100 90 80 70 60 50 40 30 20 10 0 Min Hydraulic pump performance of the F type Heat Pumps: A class pump F (5 kW and 16 kW) 7 6 5 4 Power consumption (W) External Static Pressure (kPa) Hydraulic pump performance of the F type Heat Pumps: A class pump F (5 kW and 16 kW) 3 2 1 0 10 Pump Speed 1 20 30 Water Flow Rate (L/min) Pump Speed 2 40 50 200 190 180 170 160 150 140 130 120 110 100 90 80 70 60 50 40 30 20 10 0 7 4 5 6 3 1 0 10 20 2 30 40 50 60 70 Water Flow Rate (L/min) Pump Speed 3 Pump Speed 4 Pump Speed 5 Pump Speed 6 Max 63 Heating capacity table based on outlet temperature and outside temperature Heating capacity Curve Aquarea. High Performance. Mono-Bloc Single Phase / Three Phase. Heating Only - MDF. Heating and Cooling - MDC WH-MDC12C6E5 Tamb HC IP COP HC IP COP HC IP COP HC LWC 30 30 30 35 35 35 40 40 40 45 9,30 3,50 2,66 8,90 3,66 2,43 8,50 3,83 2,22 8,10 -15 10,40 3,41 3,05 10,00 3,70 2,70 9,60 3,90 2,46 9,20 -7 11,80 3,14 3,76 11,40 3,34 3,41 11,00 3,57 3,08 10,60 2 12,00 2,14 5,61 12,00 2,57 4,67 12,00 3,00 4,00 12,00 7 12,00 1,42 8,45 12,00 1,70 7,06 11,80 1,98 5,96 11,70 25 IP 45 3,99 4,10 3,78 3,43 2,27 COP 45 2,03 2,24 2,80 3,50 5,15 HC 50 7,50 8,70 9,80 12,00 11,50 IP 50 4,09 4,20 3,98 3,82 2,53 COP 50 1,83 2,07 2,46 3,14 4,55 HC 55 7,00 8,20 9,10 12,00 11,40 IP 55 4,20 4,31 4,18 4,20 2,78 COP 55 1,67 1,90 2,18 2,86 4,10 WH-MDC14C6E5 Tamb HC LWC 30 9,90 -15 11,10 -7 12,90 2 14,00 7 14,00 25 IP 30 3,91 3,73 3,51 2,60 1,75 COP 30 2,53 2,98 3,68 5,38 8,00 HC 35 9,50 10,70 12,40 14,00 14,00 IP 35 4,05 4,00 3,73 3,11 2,10 COP 35 2,35 2,68 3,32 4,50 6,67 HC 40 9,00 10,20 11,90 14,00 14,00 IP 40 4,19 4,20 3,95 3,63 2,45 COP 40 2,15 2,43 3,01 3,86 5,71 HC 45 8,60 9,80 11,40 14,00 14,00 IP 45 4,33 4,40 4,17 4,14 2,80 COP 45 1,99 2,23 2,73 3,38 5,00 HC 50 7,90 9,10 10,40 13,60 14,00 IP 50 4,45 4,57 4,29 4,61 3,05 COP 50 1,78 1,99 2,42 2,95 4,59 HC 55 7,30 8,50 9,50 13,30 14,00 IP 55 4,56 4,74 4,40 5,08 3,44 COP 55 1,60 1,79 2,16 2,62 4,07 WH-MDC16C6E5 Tamb HC LWC 30 10,60 -15 11,90 -7 13,50 2 16,00 7 16,00 25 IP 30 4,13 4,07 3,78 3,25 2,35 COP 30 2,57 2,92 3,57 4,92 6,81 HC 35 10,30 11,40 13,00 16,00 16,00 IP 35 4,42 4,30 4,00 3,78 2,73 COP 35 2,33 2,65 3,25 4,23 5,86 HC 40 10,00 10,80 12,40 16,00 16,00 IP 40 4,71 4,50 4,22 4,31 3,11 COP 40 2,12 2,40 2,94 3,71 5,14 HC 45 9,70 10,30 11,90 16,00 16,00 IP 45 5,00 4,70 4,44 4,84 3,49 COP 45 1,94 2,19 2,68 3,31 4,58 HC 50 8,80 9,60 10,80 15,20 16,00 IP 50 4,98 4,85 4,50 5,15 3,71 COP 50 1,77 1,98 2,40 2,95 4,31 HC 55 7,90 9,00 9,80 14,50 15,90 IP 55 4,95 4,99 4,55 5,45 3,93 COP 55 1,60 1,80 2,15 2,66 4,05 WH-MDC09C3E8 Tamb HC LWC 30 8,65 -15 9,35 -7 9,31 2 9,00 7 9,00 25 IP 30 3,10 2,95 2,39 1,58 1,09 COP 30 2,79 3,17 3,90 5,70 8,26 HC 35 8,30 9,00 9,00 9,00 9,00 IP 35 3,25 3,20 2,55 1,90 1,28 COP 35 2,55 2,81 3,53 4,74 7,03 HC 40 7,95 8,85 9,00 9,00 8,73 IP 40 3,45 3,50 2,82 2,20 1,48 COP 40 2,30 2,53 3,19 4,09 5,90 HC 45 7,60 8,70 9,00 9,00 8,46 IP 45 3,65 3,80 3,09 2,50 1,68 COP 45 2,08 2,29 2,91 3,60 5,04 HC 50 7,15 8,30 8,90 9,00 8,28 IP 50 3,75 3,85 3,53 2,80 1,86 COP 50 1,91 2,16 2,52 3,21 4,45 HC 55 6,70 7,90 8,80 9,00 8,10 IP 55 3,85 3,90 3,98 3,10 2,04 COP 55 1,74 2,03 2,21 2,90 3,97 WH-MDC12C9E8 Tamb HC LWC 30 9,30 -15 10,40 -7 11,80 2 12,00 7 12,00 25 IP 30 3,50 3,41 3,14 2,14 1,42 COP 30 2,66 3,05 3,76 5,61 8,45 HC 35 8,90 10,00 11,40 12,00 12,00 IP 35 3,66 3,70 3,34 2,57 1,70 COP 35 2,43 2,70 3,41 4,67 7,06 HC 40 8,50 9,60 11,00 12,00 11,80 IP 40 3,83 3,90 3,57 3,00 1,98 COP 40 2,22 2,46 3,08 4,00 5,96 HC 45 8,10 9,20 10,60 12,00 11,70 IP 45 3,99 4,10 3,78 3,43 2,27 COP 45 2,03 2,24 2,80 3,50 5,15 HC 50 7,50 8,70 9,80 12,00 11,50 IP 50 4,09 4,20 3,98 3,82 2,53 COP 50 1,83 2,07 2,46 3,14 4,55 HC 55 7,00 8,20 9,10 12,00 11,40 IP 55 4,20 4,31 4,18 4,20 2,78 COP 55 1,67 1,90 2,18 2,86 4,10 WH-MDC14C9E8 Tamb HC LWC 30 9,90 -15 11,10 -7 12,90 2 14,00 7 14,00 25 IP 30 3,91 3,73 3,51 2,60 1,75 COP 30 2,53 2,98 3,68 5,38 8,00 HC 35 9,50 10,70 12,40 14,00 14,00 IP 35 4,05 4,00 3,73 3,11 2,10 COP 35 2,35 2,68 3,32 4,50 6,67 HC 40 9,00 10,20 11,90 14,00 14,00 IP 40 4,19 4,20 3,95 3,63 2,45 COP 40 2,15 2,43 3,01 3,86 5,71 HC 45 8,60 9,80 11,40 14,00 14,00 IP 45 4,33 4,40 4,17 4,14 2,80 COP 45 1,99 2,23 2,73 3,38 5,00 HC 50 7,90 9,10 10,40 13,60 14,00 IP 50 4,45 4,57 4,29 4,61 3,05 COP 50 1,78 1,99 2,42 2,95 4,59 HC 55 7,30 8,50 9,50 13,30 14,00 IP 55 4,56 4,74 4,40 5,08 3,44 COP 55 1,60 1,79 2,16 2,62 4,07 WH-MDC16C9E8 Tamb HC LWC 30 10,60 -15 11,90 -7 13,50 2 16,00 7 16,00 25 IP 30 4,13 4,07 3,78 3,25 2,35 COP 30 2,57 2,92 3,57 4,92 6,81 HC 35 10,30 11,40 13,00 16,00 16,00 IP 35 4,42 4,30 4,00 3,78 2,73 COP 35 2,33 2,65 3,25 4,23 5,86 HC 40 10,00 10,80 12,40 16,00 16,00 IP 40 4,71 4,50 4,22 4,31 3,11 COP 40 2,12 2,40 2,94 3,71 5,14 HC 45 9,70 10,30 11,90 16,00 16,00 IP 45 5,00 4,70 4,44 4,84 3,49 COP 45 1,94 2,19 2,68 3,31 4,58 HC 50 8,80 9,60 10,80 15,20 16,00 IP 50 4,98 4,85 4,50 5,15 3,71 COP 50 1,77 1,98 2,40 2,95 4,31 HC 55 7,90 9,00 9,80 14,50 15,90 IP 55 4,95 4,99 4,55 5,45 3,93 COP 55 1,60 1,80 2,15 2,66 4,05 Hydraulic Pump Performance. 9 kW single phase Hydraulic Pump Performance. MDC 12 to MDC 16 single phase and all MDC three phase External Static Pressure (kPa) External Static Pressure (kPa) 90 70 60 50 40 30 20 10 0 0 5 10 15 20 25 30 35 80 70 60 50 40 30 20 10 0 0 Water Flow Rate (L/min) Low Speed (I) 64 Medium Speed (II) High Speed (III) 10 20 30 40 Water Flow Rate (L/min) Pump Speed (I) Pump Speed (II) Pump Speed (III) 50 60 70 AQUAREA Cooling Capacity Curve Aquarea. High Performance. Mono-Bloc Single Phase / Three Phase. Cooling. MDC Models WH-MDC09 WH-MDC12 Tamb CC IP EER CC 5,90 1,01 5,84 7,65 16 7,45 1,59 4,69 9,20 25 7,00 2,25 3,11 10,00 35 5,80 2,59 2,24 7,60 43 IP 1,30 2,30 3,60 3,95 EER 5,88 4,00 2,78 1,92 WH-MDC14 CC 8,85 10,00 11,50 9,05 IP 1,50 2,68 4,40 5,01 EER 5,90 3,73 2,61 1,81 WH-MDC16 CC 9,62 10,51 12,20 10,08 IP 1,63 2,85 4,80 5,47 EER 5,90 3,69 2,54 1,84 Heating Capacity Curve Aquarea T-CAP. Mono-Bloc Single Phase / Three Phase. Heating. MXF / MXC WH-MXC09D3E5 Tamb HC IP COP HC IP COP LWC 30 30 30 35 35 35 9,00 3,28 2,74 9,00 3,55 2,54 -15 9,00 2,75 3,27 9,00 3,20 2,81 -7 9,00 2,40 3,75 9,00 2,55 3,53 2 9,00 1,68 5,36 9,00 1,90 4,74 7 13,60 1,54 8,83 13,60 1,75 7,77 25 HC 40 9,00 9,00 9,00 9,00 13,20 IP 40 3,95 3,66 2,82 2,20 1,97 COP 40 2,28 2,46 3,19 4,09 6,70 HC 45 9,00 9,00 9,00 9,00 12,80 IP 45 4,34 4,11 3,09 2,50 2,18 COP 45 2,07 2,19 2,91 3,60 5,87 HC 50 9,00 9,00 9,00 9,00 12,00 IP 50 4,77 4,31 3,60 2,80 2,45 COP 50 1,89 2,09 2,50 3,21 4,90 HC 55 9,00 9,00 9,00 9,00 11,20 IP 55 5,20 4,50 4,11 3,10 2,71 COP 55 1,73 2,00 2,19 2,90 4,13 WH-MXC12D6E5 Tamb HC LWC 30 12,00 -15 12,00 -7 12,00 2 12,00 7 13,60 25 IP 30 4,79 3,89 3,23 2,22 1,59 COP 30 2,51 3,08 3,72 5,41 8,55 HC 35 12,00 12,00 12,00 12,00 13,60 IP 35 5,00 4,45 3,53 2,57 1,80 COP 35 2,40 2,70 3,40 4,67 7,56 HC 40 11,50 12,00 12,00 12,00 13,40 IP 40 5,21 5,02 3,91 3,00 2,14 COP 40 2,21 2,39 3,07 4,00 6,26 HC 45 11,00 12,00 12,00 12,00 13,20 IP 45 5,42 5,58 4,29 3,43 2,47 COP 45 2,03 2,15 2,80 3,50 5,34 HC 50 10,70 12,00 12,00 12,00 12,60 IP 50 5,86 5,94 4,90 3,82 2,70 COP 50 1,83 2,02 2,45 3,14 4,67 HC 55 10,50 12,00 12,00 12,00 12,00 IP 55 6,30 6,30 5,51 4,20 2,93 COP 55 1,67 1,90 2,18 2,86 4,10 WH-MXC09D3E8 Tamb HC LWC 30 9,00 -15 9,00 -7 9,00 2 9,00 7 13,60 25 IP 30 3,28 2,75 2,40 1,68 1,54 COP 30 2,74 3,27 3,75 5,36 8,83 HC 35 9,00 9,00 9,00 9,00 13,60 IP 35 3,55 3,20 2,55 1,90 1,75 COP 35 2,54 2,81 3,53 4,74 7,77 HC 40 9,00 9,00 9,00 9,00 13,20 IP 40 3,95 3,66 2,82 2,20 1,97 COP 40 2,28 2,46 3,19 4,09 6,70 HC 45 9,00 9,00 9,00 9,00 12,80 IP 45 4,34 4,11 3,09 2,50 2,18 COP 45 2,07 2,19 2,91 3,60 5,87 HC 50 9,00 9,00 9,00 9,00 12,00 IP 50 4,77 4,31 3,60 2,80 2,45 COP 50 1,89 2,09 2,50 3,21 4,90 HC 55 9,00 9,00 9,00 9,00 11,20 IP 55 5,20 4,50 4,11 3,10 2,71 COP 55 1,73 2,00 2,19 2,90 4,13 WH-MXC12D9E8 Tamb HC LWC 30 12,00 -15 12,00 -7 12,00 2 12,00 7 13,60 25 IP 30 4,79 3,89 3,23 2,22 1,59 COP 30 2,51 3,08 3,72 5,41 8,55 HC 35 12,00 12,00 12,00 12,00 13,60 IP 35 5,00 4,45 3,53 2,57 1,80 COP 35 2,40 2,70 3,40 4,67 7,56 HC 40 12,00 12,00 12,00 12,00 13,40 IP 40 5,45 5,02 3,91 3,00 2,14 COP 40 2,20 2,39 3,07 4,00 6,26 HC 45 12,00 12,00 12,00 12,00 13,20 IP 45 5,90 5,58 4,29 3,43 2,47 COP 45 2,03 2,15 2,80 3,50 5,34 HC 50 11,50 12,00 12,00 12,00 12,60 IP 50 6,28 5,94 4,90 3,82 2,70 COP 50 1,83 2,02 2,45 3,14 4,67 HC 55 11,10 12,00 12,00 12,00 12,00 IP 55 6,66 6,30 5,51 4,20 2,93 COP 55 1,67 1,90 2,18 2,86 4,10 Cooling Capacity Curve Aquarea T-CAP. Mono-Bloc Single Phase / Three Phase. Cooling. MXC MODELS WH-MXC09 Tamb CC IP 7,00 1,40 16 7,65 1,95 25 7,00 2,25 35 6,25 2,70 43 WH-MXC12 CC 7,50 8,90 10,00 8,00 EER 5,00 3,92 3,11 2,31 IP 1,45 2,20 3,60 3,05 EER 5,17 4,05 2,78 2,62 Tamb: Ambient Temperature (°C). LWC: Leaving Water Condenser Temperature (°C). HC: Heating capacity (kW). CC: Cooling Capacity (kW). IP: Power Input (kW) This data is measured by Panasonic in accordance with EN14511-2 standard. This data is for reference purpose only, and does not guarantee the performance. Hydraulic Pump Performance. MXC 12 to MXC 16 single phase and all MXC three phase External Static Pressure (kPa) 90 80 70 60 50 40 30 20 10 0 0 10 20 30 40 50 60 70 Water Flow Rate (L/min) Pump Speed (I) Pump Speed (II) Pump Speed (III) 65 Heating capacity table based on outlet temperature and outside temperature Heating Capacity Curve Aquarea T-CAP. Bi-Bloc Single Phase / Three Phase. Heating and Cooling. SXC WH-SXC09F3E5 Tamb HC IP COP HC IP COP LWC 30 30 30 35 35 35 9,00 3,24 2,78 9,00 3,51 2,56 -15 9,00 2,71 3,32 9,00 3,16 2,85 -7 9,00 2,36 3,81 9,00 2,51 3,59 2 9,00 1,64 5,49 9,00 1,86 4,84 7 13,60 1,50 9,07 13,60 1,71 7,95 25 HC 40 9,00 9,00 9,00 9,00 13,20 IP 40 3,91 3,62 2,78 2,16 1,93 COP 40 2,30 2,49 3,24 4,17 6,84 HC 45 9,00 9,00 9,00 9,00 12,80 IP 45 4,30 4,07 3,05 2,46 2,14 COP 45 2,09 2,21 2,95 3,66 5,98 HC 50 9,00 9,00 9,00 9,00 12,00 IP 50 4,73 4,27 3,56 2,76 2,41 COP 50 1,90 2,11 2,53 3,26 4,98 HC 55 9,00 9,00 9,00 9,00 11,20 IP 55 5,16 4,46 4,07 3,06 2,67 COP 55 1,74 2,02 2,21 2,94 4,19 WH-SXC12F6E5 Tamb HC LWC 30 12,00 -15 12,00 -7 12,00 2 12,00 7 13,60 25 IP 30 4,75 3,85 3,19 2,18 1,55 COP 30 2,53 3,12 3,76 5,50 8,77 HC 35 12,00 12,00 12,00 12,00 13,60 IP 35 4,96 4,41 3,49 2,53 1,76 COP 35 2,42 2,72 3,44 4,74 7,73 HC 40 11,50 12,00 12,00 12,00 13,40 IP 40 5,17 4,98 3,87 2,96 2,10 COP 40 2,22 2,41 3,10 4,05 6,38 HC 45 11,00 12,00 12,00 12,00 13,20 IP 45 5,38 5,54 4,25 3,39 2,43 COP 45 2,04 2,17 2,82 3,54 5,43 HC 50 10,70 12,00 12,00 12,00 12,60 IP 50 5,82 5,90 4,86 3,78 2,66 COP 50 1,84 2,03 2,47 3,17 4,74 HC 55 10,50 12,00 12,00 12,00 12,00 IP 55 6,26 6,26 5,47 4,16 2,89 COP 55 1,68 1,92 2,19 2,88 4,15 WH-SXC09F3E8 Tamb HC LWC 30 9,00 -15 9,00 -7 9,00 2 9,00 7 13,60 25 IP 30 3,24 2,71 2,36 1,64 1,50 COP 30 2,78 3,32 3,81 5,49 9,07 HC 35 9,00 9,00 9,00 9,00 13,60 IP 35 3,51 3,16 2,51 1,86 1,71 COP 35 2,56 2,85 3,59 4,84 7,95 HC 40 9,00 9,00 9,00 9,00 13,20 IP 40 3,91 3,62 2,78 2,16 1,93 COP 40 2,30 2,49 3,24 4,17 6,84 HC 45 9,00 9,00 9,00 9,00 12,80 IP 45 4,30 4,07 3,05 2,46 2,14 COP 45 2,09 2,21 2,95 3,66 5,98 HC 50 9,00 9,00 9,00 9,00 12,00 IP 50 4,73 4,27 3,56 2,76 2,41 COP 50 1,90 2,11 2,53 3,26 4,98 HC 55 9,00 9,00 9,00 9,00 11,20 IP 55 5,16 4,46 4,07 3,06 2,67 COP 55 1,74 2,02 2,21 2,94 4,19 WH-SXC12F9E8 Tamb HC LWC 30 12,00 -15 12,00 -7 12,00 2 12,00 7 13,60 25 IP 30 4,75 3,85 3,19 2,18 1,55 COP 30 2,53 3,12 3,76 5,50 8,77 HC 35 12,00 12,00 12,00 12,00 13,60 IP 35 4,96 4,41 3,49 2,53 1,76 COP 35 2,42 2,72 3,44 4,74 7,73 HC 40 12,00 12,00 12,00 12,00 13,40 IP 40 5,41 4,98 3,87 2,96 2,10 COP 40 2,22 2,41 3,10 4,05 6,38 HC 45 12,00 12,00 12,00 12,00 13,20 IP 45 5,86 5,54 4,25 3,39 2,43 COP 45 2,05 2,17 2,82 3,54 5,43 HC 50 11,50 12,00 12,00 12,00 12,60 IP 50 6,24 5,90 4,86 3,78 2,66 COP 50 1,84 2,03 2,47 3,17 4,74 HC 55 11,10 12,00 12,00 12,00 12,00 IP 55 6,62 6,26 5,47 4,16 2,89 COP 55 1,68 1,92 2,19 2,88 4,15 WH-SXC16F9E8 Tamb HC LWC 30 16,00 -15 16,00 -7 16,00 2 16,00 7 16,00 25 IP 30 6,50 5,85 4,59 3,21 1,90 COP 30 2,46 2,74 3,49 4,98 8,42 HC 35 16,00 16,00 16,00 16,00 16,00 IP 35 6,89 6,42 5,16 3,74 2,40 COP 35 2,32 2,49 3,10 4,28 6,67 HC 40 16,00 16,00 16,00 16,00 16,00 IP 40 7,50 7,00 5,74 4,27 2,90 COP 40 2,13 2,29 2,79 3,75 5,52 HC 45 16,00 16,00 16,00 16,00 16,00 IP 45 8,10 7,57 6,31 4,80 3,40 COP 45 1,98 2,11 2,54 3,33 4,71 HC 50 15,60 16,00 16,00 16,00 16,00 IP 50 8,76 8,31 7,10 5,51 3,86 COP 50 1,78 1,93 2,26 2,91 4,15 HC 55 15,20 16,00 16,00 16,00 16,00 IP 55 9,41 9,05 7,88 6,21 4,31 COP 55 1,62 1,77 2,03 2,58 3,71 Cooling Capacity Curve Aquarea T-CAP. Bi-Bloc Single Phase / Three Phase. Cooling. SXC Models WH-SXC09 Tamb CC IP 7,00 1,36 16 7,65 1,91 25 7,00 2,21 35 6,25 2,66 43 WH-SXC12 CC 7,50 8,90 10,00 8,00 EER 5,15 4,01 3,17 2,35 IP 1,41 2,16 3,56 3,01 WH-SXC16 CC 9,62 10,51 12,20 10,08 EER 5,32 4,12 2,81 2,66 IP 1,59 2,81 4,76 5,43 EER 6,05 3,74 2,56 1,86 Tamb: Ambient Temperature (°C). LWC: Leaving Water Condenser Temperature (°C). HC: Heating capacity (kW). CC: Cooling Capacity (kW). IP: Power Input (kW) This data is measured by Panasonic in accordance with EN14511-2 standard. This data is for reference purpose only, and does not guarantee the performance. 110 100 90 80 70 60 50 40 30 20 10 0 Min 66 Hydraulic pump performance of the F type Heat Pumps: A class pump F (5 kW and 16 kW) 7 6 5 4 Power consumption (W) External Static Pressure (kPa) Hydraulic pump performance of the F type Heat Pumps: A class pump F (5 kW and 16 kW) 3 2 1 0 10 Pump Speed 1 20 30 Water Flow Rate (L/min) Pump Speed 2 40 50 200 190 180 170 160 150 140 130 120 110 100 90 80 70 60 50 40 30 20 10 0 7 4 3 1 0 10 20 2 30 40 Water Flow Rate (L/min) Pump Speed 3 Pump Speed 4 5 6 Pump Speed 5 Pump Speed 6 Max 50 60 70 AQUAREA Heating Capacity Curve Aquarea HT. Bi-Bloc Single Phase / Three Phase. Heating Only - SHF WH-SHF09F3E5 Tamb HC IP COP HC IP COP HC LWC 30 30 30 35 35 35 40 9,00 3,46 2,60 9,00 3,71 2,43 8,90 -15 9,00 3,06 2,94 9,00 3,29 2,74 9,00 -7 9,00 2,43 3,70 9,00 2,61 3,45 9,00 2 9,00 1,82 4,95 9,00 1,94 4,64 9,00 7 12,00 1,66 7,23 12,00 1,76 6,82 12,00 25 IP 40 4,01 3,56 2,91 2,21 2,01 COP 40 2,22 2,53 3,09 4,07 5,97 HC 45 8,80 8,90 9,00 9,00 10,80 IP 45 4,26 3,83 3,21 2,46 2,14 COP 45 2,07 2,32 2,80 3,66 5,05 HC 50 8,60 8,90 9,00 9,00 10,60 IP 50 4,61 4,11 3,55 2,76 2,46 COP 50 1,87 2,17 2,54 3,26 4,31 HC 55 8,50 8,90 9,00 9,00 10,20 IP 55 4,91 4,46 3,88 3,12 2,66 COP 55 1,73 2,00 2,32 2,88 3,83 HC 60 8,00 8,90 9,00 9,00 10,00 IP 60 5,06 4,96 4,35 3,46 2,91 COP 60 1,58 1,79 2,07 2,60 3,44 HC 65 7,80 8,90 9,00 9,00 9,80 IP 65 5,86 5,46 4,76 3,96 3,31 COP 65 1,33 1,63 1,89 2,27 2,96 WH-SHF12F6E5 Tamb LWC -15 -7 2 7 25 HC 30 12,00 12,00 12,00 12,00 12,00 IP 30 5,16 4,43 3,42 2,52 1,66 COP 30 2,33 2,71 3,51 4,76 7,23 HC 35 12,00 12,00 12,00 12,00 12,00 IP 35 5,53 4,76 3,68 2,69 1,76 COP 35 2,17 2,52 3,26 4,46 6,82 HC 40 11,00 11,50 11,50 12,00 12,00 IP 40 5,51 4,91 3,86 3,06 2,01 COP 40 2,00 2,34 2,98 3,92 5,97 HC 45 10,80 11,20 11,30 12,00 12,00 IP 45 5,49 5,06 4,14 3,44 2,41 COP 45 1,97 2,21 2,73 3,49 4,98 HC 50 10,30 10,80 11,00 12,00 12,00 IP 50 5,63 5,16 4,51 3,81 2,64 COP 50 1,83 2,09 2,44 3,15 4,55 HC 55 9,70 10,10 10,80 12,00 12,00 IP 55 5,76 5,28 4,86 4,28 2,96 COP 55 1,68 1,91 2,22 2,80 4,05 HC 60 9,00 9,85 10,65 12,00 12,00 IP 60 6,01 5,66 5,31 4,86 3,41 COP 60 1,50 1,74 2,01 2,47 3,52 HC 65 8,00 9,60 10,30 12,00 12,00 IP 65 6,11 5,91 5,59 5,41 3,86 COP 65 1,31 1,62 1,84 2,22 3,11 WH-SHF09F3E8 Tamb LWC -15 -7 2 7 25 HC 30 9,00 9,00 9,00 9,00 12,00 IP 30 3,46 3,06 2,43 1,82 1,66 COP 30 2,60 2,94 3,70 4,95 7,23 HC 35 9,00 9,00 9,00 9,00 12,00 IP 35 3,71 3,29 2,61 1,94 1,76 COP 35 2,43 2,74 3,45 4,64 6,82 HC 40 8,90 9,00 9,00 9,00 12,00 IP 40 4,01 3,56 2,91 2,21 2,01 COP 40 2,22 2,53 3,09 4,07 5,97 HC 45 8,80 8,90 9,00 9,00 10,80 IP 45 4,26 3,83 3,21 2,46 2,14 COP 45 2,07 2,32 2,80 3,66 5,05 HC 50 8,60 8,90 9,00 9,00 10,60 IP 50 4,61 4,11 3,55 2,76 2,46 COP 50 1,87 2,17 2,54 3,26 4,31 HC 55 8,50 8,90 9,00 9,00 10,20 IP 55 4,91 4,46 3,88 3,12 2,66 COP 55 1,73 2,00 2,32 2,88 3,83 HC 60 8,00 8,90 9,00 9,00 10,00 IP 60 5,06 4,96 4,35 3,46 2,91 COP 60 1,58 1,79 2,07 2,60 3,44 HC 65 7,80 8,90 9,00 9,00 9,80 IP 65 5,86 5,46 4,76 3,96 3,31 COP 65 1,33 1,63 1,89 2,27 2,96 WH-SHF12F9E8 Tamb LWC -15 -7 2 7 25 HC 30 12,00 12,00 12,00 12,00 12,00 IP 30 5,16 4,43 3,42 2,52 1,66 COP 30 2,33 2,71 3,51 4,76 7,23 HC 35 12,00 12,00 12,00 12,00 12,00 IP 35 5,53 4,76 3,68 2,69 1,76 COP 35 2,17 2,52 3,26 4,46 6,82 HC 40 11,00 11,50 11,50 12,00 12,00 IP 40 5,51 4,91 3,86 3,06 2,01 COP 40 2,00 2,34 2,98 3,92 5,97 HC 45 10,80 11,20 11,30 12,00 12,00 IP 45 5,49 5,06 4,14 3,44 2,41 COP 45 1,97 2,21 2,73 3,49 4,98 HC 50 10,30 10,80 11,00 12,00 12,00 IP 50 5,63 5,16 4,51 3,81 2,64 COP 50 1,83 2,09 2,44 3,15 4,55 HC 55 9,70 10,10 10,80 12,00 12,00 IP 55 5,76 5,28 4,86 4,28 2,96 COP 55 1,68 1,91 2,22 2,80 4,05 HC 60 9,00 9,85 10,65 12,00 12,00 IP 60 6,01 5,66 5,31 4,86 3,41 COP 60 1,50 1,74 2,01 2,47 3,52 HC 65 8,00 9,60 10,30 12,00 12,00 IP 65 6,11 5,91 5,59 5,41 3,86 COP 65 1,31 1,62 1,84 2,22 3,11 Tamb: Ambient Temperature (°C). LWC: Leaving Water Condenser Temperature (°C). HC: Heating capacity (kW). IP: Power Input (kW) This data is measured by Panasonic in accordance with EN14511-2 standard. This data is for reference purpose only, and does not guarantee the performance. 110 100 90 80 70 60 50 40 30 20 10 0 Min Hydraulic pump performance of the F type Heat Pumps: A class pump F (5 kW and 16 kW) 7 6 5 4 Power consumption (W) External Static Pressure (kPa) Hydraulic pump performance of the F type Heat Pumps: A class pump F (5 kW and 16 kW) 3 2 1 0 10 Pump Speed 1 20 30 Water Flow Rate (L/min) Pump Speed 2 40 50 200 190 180 170 160 150 140 130 120 110 100 90 80 70 60 50 40 30 20 10 0 7 4 5 6 3 1 0 10 20 2 30 40 50 60 70 Water Flow Rate (L/min) Pump Speed 3 Pump Speed 4 Pump Speed 5 Pump Speed 6 Max 67 Heating capacity table based on outlet temperature and outside temperature Heating Capacity Curve Aquarea Ht. Mono-Bloc Single Phase / Three Phase. Heating Only - MHF WH-MHF09D3E5 Tamb HC IP COP HC IP COP HC LWC 30 30 30 35 35 35 40 -15 9,00 3,50 2,57 9,00 3,75 2,40 8,90 -7 9,00 3,10 2,90 9,00 3,33 2,70 9,00 2 9,00 2,47 3,64 9,00 2,65 3,40 9,00 7 9,00 1,86 4,84 9,00 1,98 4,55 9,00 25 12,00 1,70 7,06 12,00 1,80 6,67 12,00 IP 40 4,05 3,60 2,95 2,25 2,05 COP 40 2,20 2,50 3,05 4,00 5,85 HC 45 8,80 8,90 9,00 9,00 10,80 IP 45 4,30 3,87 3,25 2,50 2,18 COP 45 2,05 2,30 2,77 3,60 4,95 HC 50 8,60 8,90 9,00 9,00 10,60 IP 50 4,65 4,15 3,59 2,80 2,50 COP 50 1,85 2,14 2,51 3,21 4,24 HC 55 8,50 8,90 9,00 9,00 10,20 IP 55 4,95 4,50 3,92 3,16 2,70 COP 55 1,72 1,98 2,30 2,85 3,78 HC 60 8,00 8,90 9,00 9,00 10,00 IP 60 5,10 5,00 4,39 3,50 2,95 COP 60 1,57 1,78 2,05 2,57 3,39 HC 65 7,80 8,90 9,00 9,00 9,80 IP 65 5,90 5,50 4,80 4,00 3,35 COP 65 1,32 1,62 1,88 2,25 2,93 WH-MHF12D6E5 Tamb LWC -15 -7 2 7 25 HC 30 12,00 12,00 12,00 12,00 12,00 IP 30 5,20 4,47 3,46 2,56 1,70 COP 30 2,31 2,68 3,47 4,69 7,06 HC 35 12,00 12,00 12,00 12,00 12,00 IP 35 5,57 4,80 3,72 2,73 1,80 COP 35 2,15 2,50 3,23 4,40 6,67 HC 40 11,00 11,50 11,50 12,00 12,00 IP 40 5,55 4,95 3,90 3,10 2,05 COP 40 1,98 2,32 2,95 3,87 5,85 HC 45 10,80 11,20 11,30 12,00 12,00 IP 45 5,53 5,10 4,18 3,48 2,45 COP 45 1,95 2,20 2,70 3,45 4,90 HC 50 10,30 10,80 11,00 12,00 12,00 IP 50 5,67 5,20 4,55 3,85 2,68 COP 50 1,82 2,08 2,42 3,12 4,48 HC 55 9,70 10,10 10,80 12,00 12,00 IP 55 5,80 5,32 4,90 4,32 3,00 COP 55 1,67 1,90 2,20 2,78 4,00 HC 60 9,00 9,85 10,65 12,00 12,00 IP 60 6,05 5,70 5,35 4,90 3,45 COP 60 1,49 1,73 1,99 2,45 3,48 HC 65 8,00 9,60 10,30 12,00 12,00 IP 65 6,15 5,95 5,63 5,45 3,90 COP 65 1,30 1,61 1,83 2,20 3,08 WH-MHF09D3E8 Tamb LWC -15 -7 2 7 25 HC 35 9,00 9,00 9,00 9,00 12,00 IP 35 3,50 3,10 2,47 1,86 1,70 COP 35 2,57 2,90 3,64 4,84 7,06 HC 35 9,00 9,00 9,00 9,00 12,00 IP 35 3,75 3,33 2,65 1,98 1,80 COP 35 2,40 2,70 3,40 4,55 6,67 HC 40 8,90 9,00 9,00 9,00 12,00 IP 40 4,05 3,60 2,95 2,25 2,05 COP 40 2,20 2,50 3,05 4,00 5,85 HC 45 8,80 8,90 9,00 9,00 10,80 IP 45 4,30 3,87 3,25 2,50 2,18 COP 45 2,05 2,30 2,77 3,60 4,95 HC 50 8,60 8,90 9,00 9,00 10,60 IP 50 4,65 4,15 3,59 2,80 2,50 COP 50 1,85 2,14 2,51 3,21 4,24 HC 55 8,50 8,90 9,00 9,00 10,20 IP 55 4,95 4,50 3,92 3,16 2,70 COP 55 1,72 1,98 2,30 2,85 3,78 HC 60 8,00 8,90 9,00 9,00 10,00 IP 60 5,10 5,00 4,39 3,50 2,95 COP 60 1,57 1,78 2,05 2,57 3,39 HC 65 7,80 8,90 9,00 9,00 9,80 IP 65 5,90 5,50 4,80 4,00 3,35 COP 65 1,32 1,62 1,88 2,25 2,93 WH-MHF12D9E8 Tamb LWC -15 -7 2 7 25 HC 35 12,00 12,00 12,00 12,00 12,00 IP 35 5,20 4,47 3,46 2,56 1,70 COP 35 2,31 2,68 3,47 4,69 7,06 HC 35 12,00 12,00 12,00 12,00 12,00 IP 35 5,57 4,80 3,72 2,73 1,80 COP 35 2,15 2,50 3,23 4,40 6,67 HC 40 11,00 11,50 11,50 12,00 12,00 IP 40 5,55 4,95 3,90 3,10 2,05 COP 40 1,98 2,32 2,95 3,87 5,85 HC 45 10,80 11,20 11,30 12,00 12,00 IP 45 5,53 5,10 4,18 3,48 2,45 COP 45 1,95 2,20 2,70 3,45 4,90 HC 50 10,30 10,80 11,00 12,00 12,00 IP 50 5,67 5,20 4,55 3,85 2,68 COP 50 1,82 2,08 2,42 3,12 4,48 HC 55 9,70 10,10 10,80 12,00 12,00 IP 55 5,80 5,32 4,90 4,32 3,00 COP 55 1,67 1,90 2,20 2,78 4,00 HC 60 9,00 9,85 10,65 12,00 12,00 IP 60 6,05 5,70 5,35 4,90 3,45 COP 60 1,49 1,73 1,99 2,45 3,48 HC 65 8,00 9,60 10,30 12,00 12,00 IP 65 6,15 5,95 5,63 5,45 3,90 COP 65 1,30 1,61 1,83 2,20 3,08 Tamb: Ambient Temperature (°C). LWC: Leaving Water Condenser Temperature (°C). HC: Heating capacity (kW). IP: Power Input (kW) This data is measured by Panasonic in accordance with EN14511-2 standard. This data is for reference purpose only, and does not guarantee the performance. Hydraulic Pump Performance WH-MHF09D3E5 // WH-MHF12D6E5 // WH-MHF09D3E8 // WH-MHF12D9E8 90 External Static Pressure (kPa) 80 70 60 50 40 30 20 10 0 0 10 20 30 40 Water Flow Rate (L/min) Pump Speed (I) 68 Pump Speed (II) Pump Speed (III) 50 60 70 AQUAREA Error Codes The operation led blinks and an error code appears on the control panel display. · Turn the unit off and inform the authorised dealer of the error code. · The timer operation is cancelled when an error code occurs. Force Heater mode button · The backup heater also serves as backup in case of malfunctioning of the outdoor unit. · Press to stop the force heater operation. · During Force Heater mode, all other operations are not allowed. Error Code List Diagnosis display H00 H12 Abnormality / Protection control No abnormality detected Indoor/Outdoor capacity unmatched Abnormality Judgement — 90s after power supply H15 H23 H38 H42 Outdoor compressor temperature sensor abnormality Indoor refrigerant liquid temperature sensor abnormality Indoor/Outdoor mismatch Compressor low pressure abnormality Continue for 5 sec. Continue for 5 sec. — — H62 H64 H70 H72 H76 H90 Water flow switch abnormality Refrigerant high pressure abnormality Back-up heater OLP abnormality Tank sensor abnormal Indoor - control panel communication abnormality Indoor / outdoor abnormal communication Continue for 1 min. Continue for 5 sec. Continue for 60 sec. Continue for 5 sec. — > 1 min after starting operation H91 H95 H98 Tank heater OLP abnormality Indoor/Outdoor wrong connection Outdoor high pressure overload protection Continue for 60 sec. — — H99 Indoor heat exchanger freeze prevention — F12 F14 F15 Pressure switch activate Outdoor compressor abnormal revolution Outdoor fan motor lock abnormality 4 times occurrence within 20 minutes 4 times occurrence within 20 minutes 2 times occurrence within 30 minutes F16 Total running current protection 3 times occurrence within 20 minutes F20 Outdoor compressor overheating protection 4 times occurrence within 30 minutes F22 IPM (power transistor) overheating protection 3 times occurrence within 30 minutes F23 Outdoor Direct Current (DC) peak detection 7 times occurrence continuously F24 Refrigeration cycle abnormality 2 times occurrence within 20 minutes F25 Cooling / Heating cycle changeover abnormality 4 times occurrence within 30 minutes F27 F36 F37 F40 F41 F42 F43 F45 F46 Pressure switch abnormality Outdoor air temperature sensor abnormality Indoor water inlet temperature sensor abnormality Outdoor discharge pipe temperature sensor abnormality PFC control Outdoor heat exchanger temperature sensor abnormality Outdoor defrost sensor abnormality Indoor water outlet temperature sensor abnormality Outdoor Current Transformer open circuit Continue for 1 min. Continue for 5 sec. Continue for 5 sec. Continue for 5 sec. 4 times occurrence within 10 minutes Continue for 5 sec. Continue for 5 sec. Continue for 5 sec. — F95 Cooling high pressure overload protection — F48 F49 Outdoor EVA outlet temperature sensor abnormality Out bypass outlet temperature sensor abnormality Continue for 5 sec. Continue for 5 sec. Primary location to verify — · Indoor/outdoor connection wire · Indoor/outdoor PCB · Specification and combination table in catalogue · Compressor temperature sensor (defective or disconnected) · Refrigerant liquid temperature sensor (defective or disconnected) · Indoor/Outdoor PCB · Outdoor pipe temperature sensor · Clogged expansion valve or strainer · Insufficient refrigerant · Outdoor PCB · Compressor · Water flow switch · Outdoor high pressure sensor (defective or disconnected) · Back-up heater OLP (Disconnection or activated) · Tank sensor · Indoor - control panel (defective or disconnected) · Internal / external cable connections · Indoor / Outdoor PCB · Tank heater OLP (Disconnection or activated) · Indoor/Outdoor supply voltage · Outdoor high pressure sensor · Water pump or water leakage · Clogged expansion valve or strainer · Excess refrigerant · Outdoor PCB · Indoor heat exchanger · Refrigerant shortage · Pressure switch · Outdoor compressor · Outdoor PCB · Outdoor fan motor · Excess refrigerant · Outdoor PCB · Compressor tank temperature sensor · Clogged expansion valve or strainer · Insufficient refrigerant · Outdoor PCB · Compressor · Improper heat exchange · IPM (Power transistor) · Outdoor PCB · Compressor · Insufficient refrigerant · Outdoor PCB · Compressor low compression · 4-way valve · V-coil · Pressure switch · Outdoor air temperature sensor (defective or disconnected) · Water inlet temperature sensor (defective or disconnected) · Outdoor discharge pipe temperature sensor (defective or disconnected) · Voltage at PFC · Outdoor heat exchanger temperature sensor (defective or disconnected) · Outdoor defrost sensor (defective or disconnected) · Water outlet temperature sensor (defective or disconnected) · Insufficient refrigerant · Outdoor PCB · Compressor low · Outdoor high pressure sensor · Water pump or water leakage · Clogged expansion valve or strainer · Excess refrigerant · Outdoor PCB · Outdoor EVA outlet temperature sensor (detective or disconnected) · Outdoor bypass outlet temperature sensor (detective or diconnected) 69 Dimensions Hydraulic Module for all models 502 353 271 205,5 98,5 97,5 97,5 228,5 241 892 38 Bi-Bloc 3 and 5kW One fan outdoor unit Two fans outdoor unit 900 900 320 620 140 620 140 320 355 400 320 355 400 140 24 140 24 1340 795 320 70 AQUAREA Mono-Bloc 6 and 9kW 1283 320 175 275 220 187 154 865 795 39 110 83,5 135 150 980 185 400 355,5 320 160 150 Mono-Bloc 9 to 16kW 1283 320 110 175 275 220 187 154 1410 1340 39 83,5 400 320 355,5 135 160 185 150 980 150 71 Do not add or replace refrigerant other than the specified type. Manufacturer is not responsible for the damage and deterioration in safety due to usage of the other refrigerant. To find out how Panasonic cares for you, log on to: www.aircon.panasonic.eu Panasonic Marketing Europe GmbH Panasonic Air Conditioning Hagenauer Strasse 43, 65203 Wiesbaden, Germany Due to the ongoing innovation of our products, the specifications of this catalogue are valid barring typographic errors, and may be subject to minor modifications by the manufacturer without prior warning in order to improve the product. The total or partial reproduction of this catalogue is prohibited without the express authorisation of Panasonic UK Ltd. www.eggeassociats.net
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement