DCS-550M Series2 Desktop Master – Wiring Information
About this document
The purpose of this document is to provide a complete wiring description,
of the selected JACQUES product.
It shows cable connections, wiring diagrams and any other details that
are required to correctly install this product.
Due to its highly technical nature, this document is intended to be used
by suitably qualified Technicians or Engineers.
For further information on the range of JACQUES products, please refer
to the separate JACQUES Intercom Systems – A Guide to
understanding the JACQUES Intercom Systems document.
For further details about JACQUES Intercom features and designs,
please read the Architects and Engineers Specification ver 2002.
These documents can be read from the website at: www.jacques.com.au
Phone: +61 7 3844 1103
Fax: +61 7 3844 1078
Web: http://www.jacques.com.au
268 Montague Road, West End,
Queensland, Brisbane, Australia 4101.
Email: [email protected]
2
268 Montague Rd, West End,
Brisbane, Australia, 4101
DCS-550M Series2 Desktop Master – Wiring Information
Contents
Wiring -------------------------------------------------------- 4
Connections ----------------------------------------------- 4
Other Information ---------------------------------------- 5
Wiring Diagram ------------------------------------------- 5
Wiring Table ----------------------------------------------- 6
Copyright © 1980 – 2002
Jacques Electronics Pty Ltd ABN 11 010 416 323
Jacques Technologies Pty Ltd ABN 48 074 448 712
The material in this document is protected by copyright under the laws of Australia.
You may view this document and its contents and save an electronic copy, or print out a copy solely
for your own information, research or study, but only if you:
● Do not modify the copy from how it originally appears unless expressly authorised by Jacques
Electronics Pty Ltd and then only in accordance with Jacques conditions.
● Include the copyright notice “© Jacques Electronics Pty Ltd” on the copy.
You must not reproduce, frame, transmit (including broadcast), adapt link to or otherwise use any of
the material on this document, except as expressly permitted by agreement with Jacques Electronics
Pty Ltd , by statute or with Jacques Electronics Pty Ltd prior written consent.
Jacques Electronics Pty Ltd reserves the right to continually improve products and updating any
equipment specifications, document context and design styling and then passing this information onto
this document.
Phone: +61 7 3844 1103
Fax: +61 7 3844 1078
Web: http://www.jacques.com.au
268 Montague Road, West End,
Queensland, Brisbane, Australia 4101.
Email: [email protected]
3
268 Montague Rd, West End,
Brisbane, Australia, 4101
DCS-550M Series2 Desktop Master – Wiring Information
Wiring
Connections
The JACQUES DCS-550M PC Master Station has two external
connections on its back panel (Figure 1).
The External Power Supply Adapter is rated at 24VDC at 1Amp. Use
the recommended JACQUES# TFM-047 power adapter.
The DB15 connector is used to directly connect into a separate
JACQUES Controller. When using a 1RU Controller, use a DB15 Male
connector (at the Controller end). If using a 3RU Controller (shown in
Figure 1), use a DB15 Female connector (at the Controller end).
! Note that the connecting cable uses RS-232 protocol and as such, it
has a maximum cable distance of 10 Metres.
Figure 1: Back panel connections of the DCS-550M Master
Phone: +61 7 3844 1103
Fax: +61 7 3844 1078
Web: http://www.jacques.com.au
268 Montague Road, West End,
Queensland, Brisbane, Australia 4101.
Email: [email protected]
4
268 Montague Rd, West End,
Brisbane, Australia, 4101
DCS-550M Series2 Desktop Master – Wiring Information
Other Information
! Refer to the separate Technical Manual DCS-550M PC Master
document, for specific Setup and Technical operations.
! Refer to the separate Operating Manual DCS-550M PC Master
document, for specific User functions.
Wiring Diagram
Figure 2 shows the wiring details of the DB15 connector, which is located
on the rear panel of the DCS-550M Master.
The other end of the cable connects directly into a JACQUES Controller.
! If it’s a 1RU type Controller, use a Male DB15 connector, if its a 3RU
type Controller, use a Female DB15 Connector.
Figure 2: Connection wiring diagram
Phone: +61 7 3844 1103
Fax: +61 7 3844 1078
Web: http://www.jacques.com.au
268 Montague Road, West End,
Queensland, Brisbane, Australia 4101.
Email: [email protected]
5
268 Montague Rd, West End,
Brisbane, Australia, 4101
DCS-550M Series2 Desktop Master – Wiring Information
Wiring Table
Table 1 shows the wiring details of the Master’s connecting cable.
This cable connects between the DCS-550M Master (DB15 connector at
the rear panel of the Master) and the JACQUES Controller (also a DB15
connector at the rear panel of the Controller).
! It is wired as a pin to pin cable, that is, pin#1 wires to pin#1, pin#2 to
pin#2, etc.
This cable uses RS-232 serial data and so it typically must be no longer
than 10 metres between Master and Controller.
Table 1-Wiring of JACQUES DCS-550M Master
Back of DCS-550M
(DB15 connector)
PIN#
wire colour
Pin Function
Comments
Not used
Microphone Audio out
(- ve)
(balanced line level)
Not used
Not used
Not used
Not used
Not used
SPEAKER Ground
1
2
Orange & White
3
4
5
6
7
8
Blue & White
9
Orange
Microphone Audio out
(+ ve)
(balanced line level)
Brown
RS-232 data Tx
Green
Brown & White and
Green & White
Blue
RS-232 data Rx
Common Ground
Not used
To Controller
Not used
From Controller
Ground
SPEAKER (+ ve)
From Controller
10
11
12
13
14
15
To Controller
Speaker
Common
To Controller
Phone: +61 7 3844 1103
Fax: +61 7 3844 1078
Web: http://www.jacques.com.au
268 Montague Road, West End,
Queensland, Brisbane, Australia 4101.
Email: [email protected]
6
268 Montague Rd, West End,
Brisbane, Australia, 4101
DCS-550M Series2 Desktop Master – Wiring Information
For further details about JACQUES Intercom features and designs,
please read the Architects and Engineers Specification ver 2002.
This document can be read from the website at: www.jacques.com.au
 copyright 2002 JACQUES ELECTRONICS Pty Ltd
Jacques Electronics Pty Ltd reserves the right to continually improve products by updating any
equipment specifications, document context and design styling and then passing this information onto
this document.
Phone: +61 7 3844 1103
Fax: +61 7 3844 1078
Web: http://www.jacques.com.au
268 Montague Road, West End,
Queensland, Brisbane, Australia 4101.
Email: [email protected]
7
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement