Greenstar 12Ri/24Ri
Greenstar 12Ri/24Ri
WALL HUNG GAS-FIRED BOILER
FOR OPEN VENT & SEALED CENTRAL HEATING SYSTEMS & INDIRECT FED DOMESTIC HOT WATER
THIS APPLIANCE IS FOR USE WITH
NATURAL GAS OR LPG (Cat II 2H3P TYPE C13 & C33)
12 Ri NATURAL GAS:
41 311 63
12 Ri LIQUID PETROLEUM GAS:
41 311 64
24 Ri NATURAL GAS:
41 311 65
24 Ri LIQUID PETROLEUM GAS:
41 311 66
USER INSTRUCTIONS &
CUSTOMER CARE GUIDE
CONTACT INFORMATION
USER INSTRUCTIONS & CUSTOMER
CARE GUIDE
WORCESTER BOSCH:
TECHNICAL: 08705 266241
SERVICE:
08457 256206
SPARES:
01905 752571
LITERATURE: 01905 752556
TRAINING:
01905 752526
SALES:
01905 752640
WEBSITE:
www.worcester-bosch.co.uk
WATER TREATMENT:
FERNOX 01799 550811
www.fernox.com
SENTINEL 0151 420 9595
www.betzdearborn.com/sentinel
FLUE TERMINAL GUARDS:
TOWER FLUE COMPONENTS
Vale Rise, Tonbridge TN9 1TB
PLEASE READ THESE INSTRUCTIONS
CAREFULLY BEFORE OPERATING YOUR
APPLIANCE
THESE INSTRUCTIONS ARE APPLICABLE TO
THE WORCESTER BOSCH APPLIANCE
MODEL(S) STATED ON THE FRONT COVER OF
THIS MANUAL ONLY AND MUST NOT BE USED
WITH ANY OTHER MAKE OR MODEL OF
APPLIANCE.
THE INSTRUCTIONS APPLY IN THE UK ONLY
AND SHOULD BE FOLLOWED EXCEPT FOR
ANY STATUTORY OBLIGATION.
IF YOU ARE IN ANY DOUBT CONTACT THE
WORCESTER BOSCH TECHNICAL HELPLINE.
DISTANCE LEARNING AND TRAINING
COURSES ARE AVAILABLE FROM
WORCESTER BOSCH.
THIS APPLIANCE MUST BE INSTALLED BY A
COMPETENT PERSON. FAILURE TO INSTALL
CORRECTLY COULD LEAD TO PROSECUTION.
PLEASE LEAVE THIS GUIDE, THE
INSTALLATION INSTRUCTIONS AND THE
COMPLETED BENCHMARK LOG BOOK WITH
THE USER OR AT THE GAS METER AFTER
INSTALLATION.
ABBREVIATIONS USED IN THIS BOOK:
NG - Natural Gas
LPG - Liquid Petroleum Gas
CH - Central Heating
SEDBUK - Seasonal Efficiency of Domestic
Boilers in the United Kingdom
USER INSTRUCTIONS &
CUSTOMER CARE GUIDE
WORCESTER BOSCH GREENSTAR 12/24Ri
8 716 106 787b (11.04)
ENERGY SAVING
TIPS ON ENERGY SAVING
9
MAINTENANCE
MAINTAINING YOUR APPLIANCE
FAULT FINDING
FAULT OR BREAKDOWN
12
13
14
GUARANTEE
YOUR GUARANTEE
GUARANTEE REGISTRATION
15
16
WORCESTER BOSCH GREENSTAR 12/24Ri
8 716 106 787b (11.04)
USING YOUR
APPLIANCE
6
7
7
7
7
7
8
ENERGY
SAVING
USING YOUR APPLIANCE
CONTROLS
OPERATING THE APPLIANCE
Switching the appliance on/off
Setting the central heating temperature
Controlling central heating
Frost protection
Fault condition
MAINTENANCE
2
3
4
GUARANTEE
INTRODUCTION
EXCELLENCE COMES AS STANDARD
SAFETY PRECAUTIONS
GENERAL NOTES
INTRODUCTION
CONTENTS
CONTENTS
1
INTRODUCTION
EXCELLENCE COMES AS STANDARD
Thank you for purchasing a Greenstar 12/24Ri
gas-fired condensing boiler manufactured by
Worcester Bosch. The company prides itself on
manufacturing boilers to the strictest quality
control standards throughout every stage of
production. Worcester Bosch has led the field
in innovative appliance design and performance
for more than 40 years. This heritage means all
products are of exceptional quality and proven
reliability.
The Greenstar range in particular, is extremely
energy efficient, converting up to 97% of gas
consumed into heat, offering you economical
running costs and value for money. It sits in
SEDBUK Band A, and is therefore amongst the
top energy rated appliances available.
There is also the reassurance of our no-nonsense
2 years parts and labour guarantee - backed up
by Worcester Total Cover, an optional complete
maintenance scheme, to keep your boiler
operating at peak condition and efficiency.
To find out more about Worcester Bosch log on
to www.worcester-bosch.co.uk .
2
EXCELLENCE COMES AS STANDARD
WORCESTER BOSCH GREENSTAR 12/24Ri
8 716 106 787b (11.04)
IF YOU SMELL GAS:
COMBUSTIBLE AND CORROSIVE MATERIALS
Extinguish any naked flame
Do not store or use any combustible materials
(paper, thinners, paints etc.) inside or within the
vicinity of the appliance.
DO NOT operate any electrical switches
Turn off the gas service cock at the meter
Open windows and doors
Telephone your gas company
IF YOU SMELL FUMES
FROM THE APPLIANCE:
Switch off the appliance,
as shown
Open windows and doors
BENCHMARK STANDARD
‘Benchmark’ is a code of practice for correctly
installing, commissioning and servicing of
domestic water heating appliances.
A Benchmark Log Book is provided by the
manufacturer for the installer to complete ALL
details together with their CORGI registration
number and sign to confirm that the boiler has
been installed and commissioned according to
the manufacturer’s instructions.
IMPORTANT: The completed Benchmark Log
Book will be required in the event of any
warranty work and may be required by the local
Building Control Inspector.
HEALTH & SAFETY
The appliance contains no asbestos and no
substances used in the construction process
contravene the COSHH Regulations (Control
of Substances Hazardous To Health
Regulations 1988).
INTRODUCTION
SAFETY PRECAUTIONS
Chemically aggressive substances, such as
halogenated hydrocarbons containing chlorine
or fluorine compounds can corrode the
appliance and invalidate any warranty.
FITTING & MODIFICATIONS
Fitting the appliance and any controls to the
appliance or removal of the outer casing may
only be carried out by a competent engineer in
accordance with the Gas Safety (Installation
and Use) Regulations.
Flue systems must not be modified in any way
other than as described in the fitting
instructions and any misuse or unauthorised
modifications to the appliance, flue or
associated components and systems could
invalidate the warranty. The manufacturer
accepts no liability arising from any such
actions. This does not affect your statutory
rights.
SERVICING
The user is recommended to have the system
regularly serviced by a competent, qualified
engineer (such as British Gas or CORGI
registered personnel) using original spares, to
help maintain the economy, safety and reliability
of the appliance and to have the Service
Record completed in the Benchmark Log Book.
The appliance should be serviced annually after
installation unless the particular installation
conditions and usage demand more frequent
services.
IMPORTANT - ensure that the service engineer
completes the Service Record in the
Benchmark Log Book after each service.
WORCESTER BOSCH GREENSTAR 12/24Ri
8 716 106 787b (11.04)
SAFETY PRECAUTIONS
3
INTRODUCTION
GENERAL NOTES
To get the best from your appliance please read
these instructions carefully.
SEALED HEATING SYSTEMS
If the appliance is fitted to a sealed heating
system, which is pre-pressurised, your installer
will advise you of the minimum and maximum
pressure which should be indicated on the
pressure gauge.
CLEARANCES - VENTILATED COMPARTMENT
Your installer will have provided adequate
space around the appliance for safety and
servicing access. Do not restrict this space with
the addition of cupboards, shelves etc. next to
the appliance.
+ 30mm
above elbow
Check regularly that the pressure is maintained
and contact your installer or maintenance
engineer if a permanent significant drop in
pressure is indicated on the pressure gauge. If
the system loses pressure it should be repressurised and the cause of the fall
investigated.
5mm
5mm
20mm*
600mm
600mm**
CENTRAL HEATING SYSTEMS
During the first few hours of operation of the
central heating system, check that all radiators
are being heated at an even rate. If the top of a
radiator is at a lower temperature than the
bottom then it should be vented by releasing air
through the venting screw at the top of the
radiator. Ask your installer to show you how this
is done.
If the boiler is fitted to a sealed system
,repeated venting will reduce the quantity of
water in the system and this must be
replenished for safe and satisfactory operation
of the appliance.
200mm
*20mm from removable door or panel
**600mm service clearance required
ROOM THERMOSTAT
A room temperature controller and programmer
should be fitted to control the central heating.
Refer to the instructions supplied with the
thermostat for information on siting and setting.
Should water leaks be found in the system or
excessive venting is required, then a service
engineer must be contacted to inspect the
installation and rectify any fault.
THERMOSTATIC RADIATOR VALVES
Only additives that are compatible with
aluminium may be used in the system. Any
incompatible additive used will invalidate the
guarantee.
CONDENSATE DRAIN
This is a condensing appliance and the terminal
will, at times give out a plume of water vapour.
This is quite normal.
It is recommended that this type of valve is
fitted to all but one of the radiators (or at least
those in the sleeping accommodation). The
remaining radiator, which must be where the
room thermostat is located, should be uncontrolled and must be left open. The
thermostatic radiator valves should conform to
the requirements of BS2767:10.
The appliance also produces quantities of
condensate which is discharged regularly, by a
siphon within the boiler, to drain.
4
GENERAL NOTES
WORCESTER BOSCH GREENSTAR 12/24Ri
8 716 106 787b (11.04)
BOILER CLEARANCES - UNVENTED
COMPARTMENT
+ 30mm
above elbow
The diagram opposite shows the minimum
space required to install and service the boiler
inside an unvented compartment.
200mm*
200mm*
100mm**
600mm***
INTRODUCTION
GENERAL NOTES
*This space can be reduced to 50mm for one
side only as long as both the side clearances
add up to the total of both the side
measurements shown or more.
VENTILATION
200mm
**100mm from removable door or panel
***600mm service clearance required
This is a room sealed appliance and does not
require any air for combustion from inside the
property. If the appliance is fitted into a
cupboard or a compartment is built around the
appliance after installation then the
compartment must be separated from the boiler
space by a perforated non-combustible partition
as described in BS 6798.
Notwithstanding the requirements of BS 6798
and BS 5440 there is no need for ventilation
openings to be provided in the compartment
because of the low heat loss from the appliance
casing, if the clearances shown are maintained.
Do not operate the appliance if the flue terminal
fitted on the outside wall or roof is obstructed
or damaged.
PUMP ANTI-SEIZURE
If there has been no heating demand for 24
hours the boiler will run the system pump for a
few seconds to reduce the possibility of pump
seizure during long periods of inactivity which is
usually more frequent during the summer
months.
WORCESTER BOSCH GREENSTAR 12/24Ri
8 716 106 787b (11.04)
SAFETY PRECAUTIONS
5
CONTROLS
1. MASTER SWITCH FOR “OFF/ON”
1
2. CENTRAL HEATING
TEMPERATURE CONTROL
USING YOUR
APPLIANCE
3. INDICATOR/DIAGNOSTICS LAMP “MAINS
ON/OFF” (BLUE)
4. BURNER “ON” INDICATOR LAMP (GREEN)
IMPORTANT: DO NOT PRESS THE INDICATOR
LAMP TO RESET THE APPLIANCE
4
3
2
6
CONTROLS
WORCESTER BOSCH GREENSTAR 12/24Ri
8 716 106 787b (11.04)
OPERATING THE APPLIANCE
SWITCHING THE APPLIANCE ON/OFF
Switching on
Switch on the appliance at the master switch (I).
Switching off
Switch off the appliance at the master switch (O).
The blue indicator lamp goes out.
SETTING THE CENTRAL HEATING TEMPERATURE
USING YOUR
APPLIANCE
The indicator lamp shows blue
Turn the central heating temperature control to
the desired level, between 35 and 82°C
When the burner is lit, the green indicator lamp
underneath the on/off switch is illuminated.
CONTROLLING CENTRAL HEATING
Set the timer to the correct time.
Set room thermostat to the desired room
temperature.
Set the thermostatic radiator valves to the
desired settings.
FROST PROTECTION
Leave master switch on.
If the temperature falls to 5°C within the boiler it
will fire to avoid the possibility of freezing.
Add a suitable anti-freeze fluid to the water in
the central heating system.
If remote pipework is likely to get frozen
ensure installer has added a frost stat.
35°C
82°C
WORCESTER BOSCH GREENSTAR 12/24Ri
8 716 106 787b (11.04)
OPERATING THE APPLIANCE
7
OPERATING THE APPLIANCE
FAULT CONDITION
In the unlikely event of a fault occurring while
the appliance is in operation:
USING YOUR
APPLIANCE
The mains indicator will flash at different speeds
dependant on fault.
To reset fault turn the thermostat / reset knob
anticlockwise then return to desired
temperature setting.
The indicator will stop flashing and the boiler
will function normally, dependant on
programmer and room thermostat settings.
If the fault remains and cannot be cleared:
Call Worcester Heat Systems Ltd. for
assistance, giving a description of the fault
and, if possible the fault flashing sequence
from the mains indicator.
8
OPERATING THE APPLIANCE
WORCESTER BOSCH GREENSTAR 12/24Ri
8 716 106 787b (11.04)
TIPS ON ENERGY SAVING
The boiler is designed to provide a high level of
comfort while keeping gas consumption and the
resulting environmental effect as low as
possible. The gas supply to the burner is
controlled according to the level of demand for
heat. The boiler continues to operate with a low
flame if the demand for heat reduces. The
technical term for this process is modulating
control. Modulating control reduces
temperature fluctuations and provides even
distribution of heat throughout the home. This
means that the boiler may stay on for relatively
long periods but will use less gas than an
appliance that continually switches on and off.
ENERGY
SAVING
Heating economically
Central heating systems with room
thermostats/thermostatic radiator valves
The central heating control on the boiler should
be set to the maximum rated temperature of the
central heating system.
The temperature of each room can be set
individually (except primary room with the room
thermostat) using the thermostatic radiator
valves. If you wish to have a lower temperature
in the primary room than in the other rooms,
leave the room thermostat at the set
temperature and turn down the radiator using
the radiator valve.
WORCESTER BOSCH GREENSTAR 12/24Ri
8 716 106 787b (11.04)
TIPS ON ENERGY SAVING
9
TIPS ON ENERGY SAVING
Roof insulation
Around 30% of the heat loss from a property is
through the roof. Replace any old insulation
with new insulation, preferably of around
200mm thickness or more.
Window frames
Single glazed windows, particularly those with
steel frames, can lose a great deal of heat.
Consideration should be given to replacement
with PVCu or wooden framed double glazed
units.
ENERGY
SAVING
Curtains
Lined curtains, or heavier full length curtains
can provide excellent insulation. However,
always ensure that the curtains do not drape
over radiators.
Draughts
Try to ensure that draughts around doors,
windows, letterboxes and keyholes etc. are
reduced by using a suitable draught excluder.
Warning - Do not block or seal any air vents
that are installed to ensure the central heating
boiler operates safely.
Room thermostats
Reducing the setting of the room thermostat by
1°C can reduce fuel consumption by up to 10%.
New control systems
Upgrade your heating control system if
necessary with the latest equipment available.
The minimum level of control is a programmer,
interlocking room thermostat and thermostatic
radiator valves.
10
TIPS ON ENERGY SAVING
WORCESTER BOSCH GREENSTAR 12/24Ri
8 716 106 787b (11.04)
TIPS ON ENERGY SAVING
Radiators
It is advisable to manually adjust all radiator
valves every 2-3 months to prevent them
sticking. It is also important that the plastic tops
of all valves are always in position and not
cracked or damaged to prevent accidents. Care
should be taken when vacuum cleaning carpets
to avoid damage to valves and pipework.
ENERGY
SAVING
More than often that not radiators will be sited
underneath a window, so the warm air from the
radiator heats the colder incoming air from the
window. The performance of the radiator will be
affected if the curtains are allowed to drape
over the radiator or shelves are fitted above it.
The positioning of furniture and tables in front
of the radiator should also be avoided.
The heating system and the outputs of the
radiators have been carefully selected by your
installer. The temperature obtainable in any
given room is dependent on all radiators being
operated at the same time. If you decide to turn
off radiators in unused rooms, spare bedrooms
etc., you may experience slightly lower room
temperatures in rooms adjacent to unheated
rooms.
WORCESTER BOSCH GREENSTAR 12/24Ri
8 716 106 787b (11.04)
TIPS ON ENERGY SAVING
11
MAINTAINING YOUR APPLIANCE
Your new Greenstar 12Ri/24Ri gas-fired
appliance represents a long term investment in
a reliable, high quality product.
In order to realise its maximum working life, and
to ensure it continues to operate at peak
efficiency and performance, it is essential that
your boiler receives regular servicing and
maintenance checks from a competent person
beyond the initial 2 year guarantee period.
If you would like to know more about a
Worcester Bosch service contract, please tick
the appropriate box on your warranty
registration card.
MAINTENANCE
If your Greenstar 12Ri/24Ri should fail to
operate correctly or requires servicing please
contact the Worcester Bosch Service
Department, see inside front cover for details.
12
MAINTAINING YOUR APPLIANCE
WORCESTER BOSCH GREENSTAR 12/24Ri
8 716 106 787b (11.04)
Problem
Cause
Remedy
Desired room
temperature is not
reached
Thermostatic radiator
valve(s) set too low
Increase thermostatic
radiator valve setting(s)
Temperature control for
CH flow on boiler set too
low
Increase CH flow
temperature control
setting
Air trapped in heating
system
Bleed radiators if fitted to
a sealed system and
recharge heating system
Desired room
temperature exceeded by
large amount
Radiators are too hot
Turn down thermostatic
radiator valves / room stat
Temperature rises
instead of falling
Clock is incorrectly set
Check setting
No on/off indicator
Momentary power failure
Switch off appliance at
master switch, wait a few
seconds then switch on
again
Hot water temperature
too low
Tank thermostat
temperature set too low
Check setting
MAINTENANCE
FAULT FINDING
Programmer setting
Diverter valve
WORCESTER BOSCH GREENSTAR 12/24Ri
8 716 106 787b (11.04)
FAULT FINDING
13
FAULT OR BREAKDOWN
This appliance is supported in the UK by
Worcester Heat Systems Ltd. - part of the
Bosch Group.
Specialist factory trained Service Engineers are
available to attend a breakdown occurring on
this appliance.
No charge will be made for parts and/or
labour providing:
An appliance fault is found and the appliance
has been installed within the past 24 months.
Reasonable evidence of this must be supplied
on request. i.e. the Benchmark Logbook.
A call-out charge will be made where:
The appliance has been installed for over 24
months
OR
Our Field Service Engineer finds no fault with
MAINTENANCE
the appliance (see Note).
OR
The cause of breakdown is misuse or with
other parts of your plumbing/heating system,
or with equipment not supplied by Worcester
Heat Systems Ltd.
Note. NO APPLIANCE FAULT IS FOUND ON
OVER 30% OF ALL SERVICE CALL OUTS.
Please read this guide carefully to gain a good
understanding of the operation of your
appliance. In the case of a suspected fault,
refer to the fault finding section of this guide.
If in doubt contact our Technical Helpline
In the event of an appliance fault or breakdown
please contact our Service Department. Your
service administrator will arrange for an
engineer to call with the minimum of delay;
under normal circumstances this will be from 1
to 3 working days (excluding weekends) for
priority breakdown situations (no hot water
and/or heating).
Invoices for attendance and repair work carried
out on this appliance by any third party will not
be accepted.
14
FAULT OR BREAKDOWN
WORCESTER BOSCH GREENSTAR 12/24Ri
8 716 106 787b (11.04)
YOUR GUARANTEE
This appliance is guaranteed against faulty
material or workmanship for a period of 2 years
from the date of installation subject to the
following terms and conditions:
During the period of this guarantee any
components of the unit which are proven to
be faulty or defective in manufacture will be
exchanged or repaired free of charge by
Worcester Heat Systems Ltd.
The householder may be asked to prove the
date of installation, that the appliance was
correctly commissioned and, where
appropriate, the first years service has been
carried out to the satisfaction of Worcester
Heat Systems Ltd. when requested. These
should be part of the Benchmark Logbook.
Any product or part returned for servicing
under the guarantee must be accompanied
by a claim stating the model, serial number,
date of installation.
Worcester Heat Systems Ltd will not accept
The appliance has been used only for normal
domestic purposes for which it was
designed.
This guarantee applies only to equipment
purchased and used in the United Kingdom.
GUARANTEE
responsibility for damage caused by faulty
installation, neglect, misuse or accidental
damage or the non observance of the
instructions contained in the Installation and
Servicing Manual and users instructions.
This guarantee does not affect your statutory
rights.
WORCESTER BOSCH GREENSTAR 12/24Ri
8 716 106 787b (11.04)
YOUR GUARANTEE
15
GUARANTEE REGISTRATION
You should complete and return the postpaid
Guarantee Registration Card within 14 days of
purchase.
Returning the card will register you as the
owner of your new Greenstar 12Ri/24Ri
appliance and will assist us in maintaining an
effective and efficient customer service by
establishing a reference and permanent record
for your boiler.
This does not affect your statutory rights.
For your own record:
Model
Serial No.
(See identity label inside appliance casing)
Type / size
Date of installation
GUARANTEE
Check that the Benchmark “Log Book” has
been completed by your installer or service
engineer.
16
GUARANTEE REGISTRATION
WORCESTER BOSCH GREENSTAR 12/24Ri
8 716 106 787b (11.04)
USER INSTRUCTIONS &
CUSTOMER CARE GUIDE
EXCELLENCE COMES AS STANDARD
Worcester Heat Systems Ltd (Bosch Group)
Cotswold Way, Warndon, Worcester WR4 9SW.
Tel. 01905 754624 Fax. 01905 754619
www.worcester-bosch.co.uk
8 716 106 787b (11.04)