Anritsu S3xxE
Product Brochure
Site Master
TM
Compact Handheld Cable & Antenna Analyzer
with Spectrum Analyzer
S331E
S332E
S361E
S362E
2 MHz to 4 GHz
2 MHz to 4 GHz
2 MHz to 6 GHz
2 MHz to 6 GHz
Cable & Antenna Analyzer
100 kHz to 6 GHz
Spectrum Analyzer
100 kHz to 4 GHz
From the leader in cable and antenna analysis
Anritsu introduces its 8th generation site master
Although the new Site Master resides in a modern
platform that takes advantage of the latest technologies
and is loaded with features that will enhance productivity,
it provides more value for better productivity without
giving up the familiar look and feel.
INTEGRATED
The Site Master is a 4 or 6 GHz cable and antenna
analyzer that can be configured to include either a
4 or 6 GHz spectrum analyzer, 2-port transmission
measurement with built-in 32V bias tee, an interference
analyzer with spectrogram displays, a channel scanner,
power meter, high accuracy power meter, and GPS
receiver for time and location stamping. Because of its
multi-functional capabilities, it eliminates the need for you
to carry and learn multiple instruments.
TRUSTED
The wireless communications market continues to evolve
at a rapid pace. Operators and service providers have
to maintain old networks while upgrading to the new
3G and 4G networks so as to keep up with changing
consumer demands. They face the additional challenge of
needing to ensure their networks are competitive from a
reliability, quality, and cost perspective. As a result of all
this, they expect more of the contractors and technicians
who maintain their networks. To stay competitive, these
contractors and technicians must maintain more base
stations than before and complete a wide variety of tasks
in the shortest time possible.
Anritsu is pleased to introduce its eighth-generation
compact handheld Site Master cable and antenna analyzer
series with integrated spectrum analyzer. The new Site
Master analyzers offer the same ease of use, ruggedness,
and familiar menus as its predecessor S331D and S332D.
In addition, Anritsu has enhanced the Site Master to
address all the customer requirements and suggestions
received over the years.
Indeed, for more than 14 years, Anritsu’s Site Master has
been the de facto standard for contractors, installers, and
wireless service providers who need a portable and rugged
cable and antenna analyzer. The Site Master reduces per
site maintenance expense, maximizes system up-time,
and breaks away from the traditional fix-after-failure
maintenance mode by finding small problems before
major failures occur. Radio frequency (RF) engineers and
field technicians in the U.S. Navy, U.S. Air Force, and
other global defense programs responsible for installing
and maintaining communication systems use Site Master’s
frequency domain reflectrometry (FDR)-based approach
to improve the quality of their communication systems.
2
Anritsu builds upon its expertise in portable compact
cable and antenna analyzers and spectrum analyzers. The
Site Master is approved by all major operators and service
providers worldwide.
DESIGNED FOR FIELD USE
The Site Master was designed specifically for field
environments. It weighs less than 6 lbs and its field
replaceable Li-Ion battery typically lasts for more than
4 hours. A new bright 8.4-inch color display provides
visibility even in broad daylight. With an operating
temperature range from -10° to 55 °C, the Site Master
will work in the most extreme weather conditions. The
analyzer is almost impervious to the bumps and bangs
typically encountered by portable field equipment, and
its ruggedized case and splash proof design allow you to
depend on high performance anywhere, anytime.
site master is the preferred cable and antenna analyzer
of wireless service providers, contractors and installers
Integrated
Measurement
Capabilities
CONFIGURATION OVERVIEW
FUNCTION
DESCRIPTION
Cable and Antenna Analyzer, 2 MHz to 4/6 GHz
Characterizes cable and antenna systems with return loss, cable
loss, VSWR, distance-to-fault measurements. Also includes 1-port
phase and Smith chart displays. Offers faster than 1 ms/data point
sweep speed and a dual display.
Spectrum Analyzer, 100 kHz to 4/6 GHz
Locates and identifies various signals over a wide frequency range.
Detect signals as low as -152 dBm with phase noise better than
-100 dBc/Hz.
2-port Transmission Measurement (Option 21)
Provides high and low power settings for both TMA gain and
antenna-antenna isolation measurements. Offers better than 80 dB
dynamic range.
Bias Tee (Option 10)
Provides built-in 32 V bias tee that can be turned on as needed,
and which eliminates the need to carry an external supply.
High Accuracy Power Meter (Option 19)
Connects high accuracy 6-, 8-, and 18 GHz USB power sensors
with better than 0.16 dB accuracy.
Power Meter (Option 29)
Makes channelized transmitter power measurements.
Interference Analyzer (Option 25)
Includes the popular spectrogram display for monitoring
intermittent signals over time.
Channel Scanner (Option 27)
Measures the power of multiple transmitted signals.
CW Signal Generator (Option 28)
Includes CW source to test low noise amplifiers, repeaters.
(This requires an external CW generator kit.)
GPS Receiver (Option 31)
Provides location and UTC time information. Also improves the
accuracy of the reference oscillator.
Gated Sweep (Option 90)
Views pulsed or burst signals such as WiMAX, GSM, and
TD-SCDMA only when they are on.
3
designed for the field
External
Reference
EXTernal trigger
T1 E1 Ref. Freq.
usb interface mini-B
Transfer data from Site Master to PC
GPS CONNECtor
External power
RF Out
RF IN
usb interface type a
Connect USB flash card
ALL CONNECTORS ARE CONVENIENTLY LOCATED ON THE TOP PANEL, LEAVING THE ORDER CLEAR FOR HANDHELD USE.
GPS INFO
SAVE ICON
TOUCH SCREEN
SUBMENU KEYS
FAN EXHAUST
pORT
FAN INLET PORT
rotary knob
& arrow keys
limit lines
Create single
& multi-segment
limit lines
Bright Display
8.4” daylight viewable
color display
NUMERIC KEYPAD
SHIFT MENU KEYS (1 TO 9)
BATTERY ACCESS
Battery life > 4 hours
PRINTED IN BLUE
FAN INLET PORT
TOUCH SCREEN
Main Menu Keys
on/off button
file management
Saves & Recall > 2000 traces & setups
4
convenient SOFT CASE AND TILT BAIL
tilt bails are integrated into the case and soft case for better screen viewing
5
master Cable & Antenna analysis, anywhere, anytime
The majority of the problems you find at a typical cell site are caused by problematic cables, pinched cables, corroded
connectors, antennas, lightning strikes, rain getting into cables, and bullet holes. Degraded cable systems and badly positioned
antennas affect overall system coverage and eventually result in dropped calls. Site Master’s FDR-based return loss and DTF
measurements can pinpoint an antenna problem from ground level in a few seconds, enabling Site Master to identify small
problems before they become big problems.
Return Loss / VSWR
Use the Site Master to make return loss and VSWR and verify that the
cable and antenna system conforms to performance specifications.
Cable Loss
Cable Loss metrics measure the level of insertion loss within the cable
feedline system. This measurement can be verified prior to deployment,
when you have access to both ends. Site Master automatically calculates
the average cable loss.
Return Loss/VSWR
Distance-To-Fault
While the return loss metric is the best measurement to verify the health of
a system, distance-to-fault (DTF) is used to troubleshoot systems and locate
the problem.
The Site Master’s DTF measurement uses the fast Fourier transform to
convert frequency data to the time domain and displays signal anomalies
with respect to distance. Using the standard trace math feature, you can
monitor small relative changes over time.
Distance-to-Fault
2-port Transmission Measurements (Option 21)
Cellular/PCS and 3G base stations today use diplexers, duplexers, and
tower-mounted amplifiers to extend the coverage area. Site Master’s 2-port
transmission measurement enables you to make gain, isolation, and insertion
loss measurements as well as verify sector-to-sector isolation.
bias tee (option 10)
The built-in bias tee can be turned on as needed to place +12 to +32V on
the center conductor of the RF in port, eliminating the need for you to carry
external supplies in the field.
2-Port Transmission Measurements
6
enhance productivity with dual displays and instant calibration
Dual Display
The dual display enables users to view two cable and antenna measurements
on the same display. Because you can control the top and bottom displays
independently, you can set markers and limit lines on each display.
This results in significant time savings as there’s no need to make two
measurements.
Smith Chart and 1-port Phase Display
Dual Display
The cable and antenna analyzer also includes Smith chart and 1-port
phase measurement displays for when you need to tune antennas and
phase match cables.
InstaCal™ Calibration
Although you need to get the job done as quickly as possible, you still need
to make reliable and accurate measurements. Anritsu’s InstaCal module
enables you to make accurate calibrations at the end of the phase stable
cable without connecting a short/open/load. You only need to connect the
InstaCal module once and everything is done automatically. This calibration
method can cut the calibration time by as much as 50 percent and still deliver
accurate calibrations. Directivity specification for the InstaCal module is
38 dB for the entire frequency range, allowing you to make fast and accurate
measurements in no time—and with no in-between connections.
Smith Chart
Standard OSL Calibration
Open-Short-Load (OSL) calibration comes standard with the
Site Master. All errors from source match, directivity, and frequency response
are mathematically removed, allowing you to make accurate vector-corrected
measurements. Directivity is usually the main contributor to measurement
uncertainty, and corrected directivity of 42 dB or better is common using
Anritsu’s precision components.
FlexCal™
The Site Master’s FlexCal™ broadband calibration feature is an
OSL-based calibration method that allows you to perform a broadband
calibration and change the frequency range after calibration without having
to recalibrate the instrument.
InstaCal
RF Immunity
Site Master’s special dithering RF immunity solution enables you to make
accurate cable and antenna measurements even in the presence of strong RF
activity from co-located cell sites.
cable and antenna Analyzer highlights
- Return loss, VSWR, cable loss, DTF
- < 1 msec per datapoint sweep speed
- 2-port transmission measurements with 32V bias tee
- 1-port phase, Smith chart
- Trace overlay and trace math to monitor changes with
reference traces
- Optical DTF measurements
- Marker table with automatic peak/valley markers
- Dual display mode capabilities
- GPS tagging
- Built-in, editable signal standard and cable standard lists
- Limit lines and alarming for providing reference standards
- Calibration: OSL Cal, FlexCal, InstaCal
- GPS tagging of data to verify location of tests
- 137, 275, 551, 1102, 2204 data points
- Master Software Tools for post-analysis and report generation
7
high performance, compact Spectrum Analysis
Site Master S332E and the S362E Site Master with integrated spectrum analysis capability provide users with a highperformance, easy-to-use, feature-rich spectrum analyzer for field environments and applications requiring mobility.
Site Master’s integrated high performance spectrum analyzer makes it ideal for a broad range of activities, including spectrum
monitoring, AM/FM broadcast proofing, interference analysis, field strength measurements, transmitter spectrum analysis,
electro magnetic field strength, signal strength mapping, and overall field analysis of cellular 2G/3G/4G, land mobile radio,
Wi-Fi, and broadcast signals.
High Performance
Site Master’s dynamic range is better than 95 dB in 10 Hz RBW, allowing
you to measure very small signals in the presence of much larger signals.
The picture to the left demonstrates the dynamic range in Site Master.
Additionally, Site Master’s phase noise is better than -100 dBc/Hz at
10 kHz offset. The integrated 4 or 6 GHz spectrum analyzer delivers
-152 dBm DANL in 10 Hz RBW.
Fast Sweep Speed
Dynamic Range Performance
It automatically sets the fastest sweep possible and still delivers accurate
measurements. This allows you to rely on Site Master to optimize accuracy
and consistency.
Smart Measurements
Site Master comes with commonly needed and easily accessed
measurements built in. These include field strength, occupied bandwidth,
channel power, adjacent channel power ratio (ACPR), AM/FM/SSB
demodulation, and carrier-to-interference (C/I) ratio measurements.
Occupied Bandwidth
Determine the amount of spectrum used by a modulated signal. You can
choose between two different methods of determining bandwidth: the
percent-of-power method or the “x” dB down method.
Smart Measurements
Adjacent Channel Power Ratio
Adjacent Channel Power Ratio is a common transmitter measurement. This
is the ratio of the amount of leakage power in the adjacent channel to the
total transmitted power in the main channel. This measurement can be used
to replace the traditional two-tone intermodulation distortion (IMD) test
for system non-linear behavior. The Site Master allows you to perform this
measurement quickly and accurately.
Field Strength Measurements
The Site Master can determine the effects of electromagnetic fields caused
by transmitter systems, and automatically take specific antenna factors of
the connected antenna into account.
8
master the location of interference
As the wireless industry continues to expand, more diverse uses for the radio spectrum emerge and the number of signals that may
potentially cause interference is constantly increasing.
Compounding the problem are the many sources that can generate interference including intentional radiators, un-intentional
radiators, and self interference. Interference causes Carrier-to-Interference degradation robbing the network of capacity. The goal of
these measurements is to resolve interference issues as quickly as possible.
Interference Analysis (Option 25)
The interference analyzer option provides you with a spectrogram display,
RSSI, signal strength meter, and signal ID. Site Master’s integrated
spectrum analyzer can detect signals as low as -152 dBm.
Spectrogram Display
This option provides you with a three-dimensional display of frequency,
power, and time of the spectrum activity to identify intermittent
interference and track signal levels over time. The Site Master allows you
to save a history up to 72 hours.
Spectrogram Display
Received Single Strength Indicator (RSSI)
You can use the Site Master’s RSSI measurement to observe the
signal strength of a single frequency over time, and collect data for up to
72 hours.
Signal Strength Meter
The Site Master’s signal strength meter can locate an interfering signal by
using a directional antenna and measuring the signal strength. It displays
power in Watts, dBm, in the graphical analog meter display, and by an
audible beep proportional to its strength.
Signal Strength Meter
Signal ID
Site Master’s signal ID feature in the interference analyzer can help you
quickly identify the type of the interfering signal. You can configure
this measurement to identify all signals in the selected band or to simply
monitor one single interfering frequency. The Site Master then displays
results that include center frequency, signal bandwidth, and signal type
(FM, GSM/GPRS/EDGE, W-CDMA/HSDPA, CDMA/EV-DO, Wi-Fi).
am/fm/ssb demodulation
Signal ID
A bulit-in demodulator for AM, narrowband FM, wideband FM and single
sideband allows you to easily identify the interfering signal.
spectrum Analyzer highlights
- Measurements: Occupied bandwidth, channel power, ACPR, C/I,
AM/FM demod, field strength
- Advanced marker functions: noise marker, frequency counter,
fixed, tracking
- Interference analyzer: spectrogram, signal strength, RSSI, signal ID - Advanced limit line functions: one-button envelope creation
- Dynamic range: > 95 dB
- Detection methods: peak, RMS, negative, sample, quasi-peak
- DANL: -162 dBm typical (normalized to 1 Hz)
- Save-on-event: automatically saves a sweep when crossing a
limit line
- Phase noise: -100 dBc/Hz @ 10 kHz offset
- Frequency accuracy: < +/- 50 ppb with GPS on
- Gated sweep: view pulsed or burst signals only when they
are on, or off
9
Power Measurements for a Wide Range of Applications
The Anritsu Site Master provides many different power measurements to support a wide range of applications. The highaccuracy broadband sensor family provides the best accuracy (±0.16 dB) over a wide frequency range. The power meter is
ideal for users looking to making channelized measurements in a few keystrokes with minimal training. Site Master’s channel
power measurement also makes channelized measurements but requires more knowledge and is recommended for more
advanced users. And when you are measuring multiple channels, the channel scanner is your perfect choice.
Channel Power
Use Site Master’s channel power measurement to determine the power and
power density of a transmission channel. Using the built-in signal standard
list, you can meaure the channel power of a wide range of signals.
Power Meter (Option 29)
Site Master’s internal power meter provides power measurements
without any additional tools and is ideal for making channelized power
measurements.You can display the results in both dBm and Watts.
This option is easy to use and requires limited setup entries.
Power Meter
High Accuracy Power Meter (Option 19)
Anritsu’s high accuracy power meter option enables you to make high
accuracy RMS measurements. This capability is perfect for measuring both
CW and digitally modulated signals such as CDMA/EV-DO, GSM/EDGE,
WCDMA/HSDPA, and P25. You can select from a wide range of USB
sensors delivering better than ±0.16 dB accuracy. An additional benefit of
using the USB connection is that a separate DC supply (or battery) is not
needed since the necessary power is supplied by the USB port.
- P
SN50 High Accuracy RF Power Sensor, 50 MHz to 6 GHz,
-30 to +20 dBm, True-RMS
High Accuracy Power Meter
- M
A24104A Inline High Power Sensor, 600 MHz to 4 GHz,
+3 to +51.76 dBm (150W), True-RMS
- M
A24106A High Accuracy RF Power Sensor, 50 MHz to 6 GHz,
-40 to +23 dBm, True-RMS
- M
A24108A Microwave USB Power Sensor, 10 MHz to 8 GHz,
-40 to +20 dBm, True-RMS
- M
A24118A, Microwave USB Power Sensor, 10 MHz to 18 GHz,
-40 to +20 dBm, True-RMS
PC Power meter
High Accuracy Power Sensors
These power sensors can be used with a PC running Microsoft Windows®
via USB. They come with PowerXpert™ application, a data analysis, and
control software. The application has abundant features, such as data
logging, power versus time graph, big numerical display, and many more,
that enable quick and accurate measurements.
Channel Scanner (Option 27)
Channel Scanner
10
The channel scanner option measures the power of multiple transmitted
signals, making it very useful for simultaneously measuring channel power
of up to 20 channels in GSM, TDMA, CDMA, W-CDMA, HSDPA, and
public safety networks. You can select the frequencies or the scanned data to
be displayed by frequencies or the channel number. And in the custom setup
menu each channel can be custom built with different frequency bandwidth,
or with channels from different signal standards. With Script Master, scans
can be automated for up to 1200 channels.
valuable options and features
GPS Receiver (Option 31)
Site Master’s GPS option can be used to confirm the exact measurement
location (longitude, latitude, altitude) and Universal Time (UT) information.
Each trace can be stamped with location information to ensure you are
taking measurements at the right location.
In addition, the GPS option enhances the frequency accuracy of the
internal reference oscillator. Within three minutes of acquiring the GPS
satellite, the built-in GPS receiver provides a frequency accuracy to better
than 50 ppb.
GPS Receiver
CW signal Generator (Option 28)
This option provides a CW signal generator from 2 MHz to 4 or 6 GHz.
The signal at the output port can be set high (about 0 dBm) or low (-30 dBm).
With the use of the CW Signal Generator Kit’s attenuator connected to
the RF port, the level can be varied in 1 dB steps giving you the ability to
generate signals as low as -110 dBm for receiver sensitivity measurements.
The included splitter divides the signal allowing for a simultanious power
measurement.
CW Signal Generator
Built-in Keyboard
The built-in touchscreen keyboard gives you access to a fully functional
keyboard, saving valuable time in the field when entering trace names.
You can create shortcuts to customer-configurable user “quick names” to
program frequently used words.
Touchscreen keyboard
Menus with shortcut icons
Find your favorite measurements quickly by pressing the menu key. Create
shortcuts for popular measurements, setups, and functions by simply holding
down any key for more than three seconds. The display here shows the menu
with standard measurements and with the lower part filled with shortcut icons.
Local Language Support
Site Master features eight languages including English, Japanese, Chinese,
Italian, French, German, Spanish and Korean. Two custom user-defined
languages can be uploaded into the instrument using Master Software Tools.
Menus with shortcut icons
11
MASTEr Software tools - the power behind the site Master
Master Software Tools (MST) is a powerful PC software post-processing tool designed to enhance the productivity of technicians in report
generation, data analysis, and testing automation.
Fast Downloads
Download all measurements to MST with a single menu selection.
Report Generation
Create reports with company logo, GPS tagging information, calibration
status, and serial number of the instrument for complete reporting.
Add custom company logos.
Import HHST *.DAT Files
Connect to PC using USB
Compatibility is retained with Handheld Software Tools (HHST) with a *.dat
file converter which converts HHST files to MST file format and vice-versa.
Master Software Tools Report
Anritsu
Prepared for:
Location:
Date:
John Smith
Date: 10/20/2005 2:08:50 PM
Compare Traces
Use MST to build a record of all traces. Easy to use trace overlay features
allow for easy comparison with historical traces.
Measurement Summary
.
Calibration Status
Data Points
.
On, FlexCal
551
RF Immunity
Averaging
Smoothing %
High
OFF
0
Device Summary
Serial Number
Base Ver.
987654321
T1.25.0200
App Ver.
Date
T1.30.0001
10/20/2005 2=08=50 PM
Trace Renaming
Rename hundreds of traces in minutes using the trace rename tool in MST.
Report Generation
Trace Editor
For VNA traces, select markers to peak and valley and displays individual
values for Return Loss, Cable Loss, VSWR, Magnitude, Phase and milliRho.
For SPA measurements set limit line envelopes, edit limit lines segments and
turn on and off segments. Also, edit frequency and amplitude parameters.
Product Updates
The product update tool will ensure you always use the latest instrument
firmware.
Import HHST *.DAT Files
Group Edit
Add limit lines and markers to all the traces in one folder with just one click.
Signal Standards and Cable Lists
While the Site Master signal standard and cable lists are updated frequently,
Master Software Tools can be used to add custom signals and cables.
Multiple Trace View and Trace Converter
Multiple Trace View
Create multiple trace displays (RL, VSWR, Cable Loss, DTF, Phase) from a
single 1-port measurement.
Full Trace Retrieval
Download and archive hundreds of traces instantly to your PC without
opening them.
Folder Spectrogram
3D Spectrogram View
12
Folder Spectrogram – creates a composite file of up to 15,000 multiple traces
for quick review.
ordering information
S331E
S332E
S361E
S362E
2 MHz to 4 GHz
2 MHz to 4 GHz
2 MHz to 6 GHz
2 MHz to 6 GHz
100 kHz to 4 GHz
100 kHz to 6 GHz
DESCRIPTION
Cable and Antenna Analyzer
Spectrum Analyzer
S331E-0021
S332E-0021
S361E-0021
S362E-0021
2-Port Transmission Mearsurement
S331E-0010
S332E-0010
S361E-0010
S362E-0010
Bias-Tee (Requires Option 0021 for S3331E/S361E)
S331E-0031
S332E-0031
S361E-0031
S362E-0031
GPS Receiver (Requires Antenna P/N 2000-1528-R)
SS331E-0019
S332E-0019
S361E-0019
S362E-0019
High-Accuracy Power Meter
S332E-0029
S362E-0029
Power Meter
S332E-0025
S362E-0025
Interference Analyzer
S332E-0027
S362E-0027
Channel Scanner
S332E-0090
S362E-0090
Gated Sweep
S332E-0028
S362E-0028
CW Signal Generator (Requires CW Signal Generator Kit, P/N 69793)
S331E-0098
S332E-0098
S361E-0098
S362E-0098
Standard Calibration to Z540
S331E-0099
S332E-0099
S361E-0099
S362E-0099
Premium Calibration to Z540 plus test data
power sensors (For complete ordering information see the respective datasheets for each sensor)
MODEL NUMBER
PSN50
DESCRIPTION
High Accuracy RF Power Sensor, 50 MHz to 6 GHz, +20 dBm
MA24104A Inline High Power Sensor, 600 MHz to 4 GHz, +51.76 dBm
MA24106A High Accuracy RF Power Sensor, 50 MHz to 8 GHz, +23 dBm
MA24108A Microwave USB Power Sensor, 10 MHz to 8 GHz, +20 dBm
MA24118A Microwave USB Power Sensor, 10 MHz to 18 GHz, +20 dBm
manuals (Soft copy included on MST CD and at www.us.anritsu.com)
NUMBER
10580-00252
DESCRIPTION
Site Master User Guide (Hard copy included)
–Bias-Tee, GPS Receiver
10580-00230
Cable and Antenna Analyzer Measurement Guide
–Bias-Tee
10580-00242
2-Port Transmission Measurement
10580-00231
Spectrum Analyzer Measurement Guide
–Interference Analyzer, Channel Scanner, Gated Sweep,
CW Signal Generator
10580-00240
Power Meter Measurement Guide
–High Accuracy Power Meter
10580-00215
ODTF-1 Optical Distance-to-Fault Module
10580-00256
Programming Manual
10580-00253
Maintenance Manual
standard accessories (Included with instrument)
NUMBER
10580-00252
3-68736
2300-498
633-44
40-168-R
806-141-R
DESCRIPTION
Site Master User Guide (Includes Bias-Tee, GPS Receiver)
Soft Carrying Case
MST CD: Master Software Tools, User/Measurement Guides,
Programming Manual, Troubleshooting Guides, Application Notes
Rechargeable Li-Ion Battery
AC-DC Adapter
Automotive Cigarette Lighter 12 VDC Adapter
3-2000-1498
USB A/5-pin mini-B Cable, 10 feet/305 cm
11410-00484
Site Master™ S331E, S332E, S361E, S362E Technical Data
Sheet, One Year Warranty (Including battery, firmware, and
software), Certificate of Calibration and Conformance
13
optional accessories
Calibration Components, 50 Ω
Part Number
ICN50B
Description
InstaCal™ Calibration Module, 2 MHz to 6.0 GHz, N(m), 50 Ω
OSLN50-1
Precision Open/Short/Load, N(m), 42dB, 6.0 GHz, 50 Ω
OSLNF50-1
Precision Open/Short/Load, N(f), 42dB, 6.0 GHz, 50 Ω
2000-1618-R
Precision Open/Short/Load, 7/16 DIN(m), DC to 6.0 GHz 50 Ω
2000-1619-R
Precision Open/Short/Load, 7/16 DIN(f), DC to 6.0 GHz 50 Ω
22N50
Open/Short, N(m), DC to 18 GHz, 50 Ω
22NF50
Open/Short, N(f), DC to 18 GHz, 50 Ω
SM/PL-1
Precision Load, N(m), 42 dB, 6.0 GHz
SM/PLNF-1
Precision Load, N(f), 42 dB, 6.0 GHz
Calibration Components, 75 Ω
22N75
Open/Short, N(m), DC to 3 GHz, 75 Ω
22NF75
Open/Short, N(f), DC to 3 GHz, 75 Ω
26N75A
Precision Termination, N(m), DC to 3 GHz, 75 Ω
26NF75A
Precision Termination, N(f), DC to 3 GHz, 75 Ω
12N50-75B
Matching Pad, DC to 3 GHz, 50 Ω to 75 Ω
Phase-Stable Test Port Cables, Armored w/ Reinforced Grip (recommended for cable & antenna line sweep applications)
15RNFN50-1.5-R
1.5 m, DC to 6 GHz, N(m) - N(f), 50 Ω
15RDFN50-1.5-R
1.5 m, DC to 6 GHz, N(m) - 7/16 DIN(f), 50 Ω
15RDN50-1.5-R
1.5 m, DC to 6 GHz, N(m) - 7/16 DIN(m), 50 Ω
15RNFN50-3.0-R
3.0 m, DC to 6 GHz, N(m) - N(f), 50 Ω
15RDFN50-3.0-R
3.0 m, DC to 6 GHz, N(m) - 7/16 DIN(f), 50 Ω
15RDN50-3.0-R
3.0 m, DC to 6 GHz, N(m) - 7/16 DIN(m), 50 Ω
Phase-Stable Test Port Cables, Armored (recommended for use with tightly spaced connectors and other general purpose applications)
15NNF50-1.5C
1.5 m, DC to 6 GHz, N(m) - N(f), 50 Ω
15NN50-1.5C
1.5 m, DC to 6 GHz, N(m) - N(m), 50 Ω
15NDF50-1.5C
1.5 m, DC to 6 GHz, N(m) - 7/16 DIN(f), 50 Ω
15ND50-1.5C
1.5 m, DC to 6 GHz, N(m) - 7/16 DIN(m), 50 Ω
15NNF50-3.0C
3.0 m, DC to 6 GHz, N(m) - N(f), 50 Ω
15NN50-3.0C
3.0 m, DC to 6 GHz, N(m) - N(m), 50 Ω
Adapters
1091-26-R
SMA(m) - N(m), DC to 18 GHz, 50 Ω
1091-27-R
SMA(f) - N(m), DC to 18 GHz, 50 Ω
1091-80-R
SMA(m) - N(f), DC to 18 GHz, 50 Ω
1091-81-R
SMA(f) - N(f), DC to 18 GHz, 50 Ω
1091-172
BNC(f) - N(m), DC to 1.3 GHz, 50 Ω
510-90
7/16 DIN(f) - N(m), DC to 7.5 GHz, 50 Ω
510-91
7/16 DIN(f) - N(f), DC to 7.5 GHz, 50 Ω
510-92
7/16 DIN(m) - N(m), DC to 7.5 GHz, 50 Ω
510-93
7/16 DIN(m) - N(f), DC to 7.5 GHz, 50 Ω
510-96
7/16 DIN(m) - 7/16 DIN (m), DC to 7.5 GHz, 50 Ω
510-97
7/16 DIN(f) - 7/16 DIN (f), DC to 7.5 GHz, 50 Ω
1091-379-R
510-102-R
7/16 DIN(f) - 7/16 DIN(f), DC to 6 GHz, 50 Ω, w/ Reinforced Grip
N(m) - N(m), DC to 11 GHz, 50 Ω, 90 degrees right angle
Precision Adapters
34NN50A
34NFNF50
Precision Adapter, N(m) - N(m), DC to 18 GHz, 50 Ω
Precision Adapter, N(f) - N(f), DC to 18 GHz, 50 Ω
Miscellaneous Accessories
2000-1528-R
69793
ODTF-1
2000-1520-R
2000-1374
14
GPS Antenna, SMA(m)
CW Signal Generator Kit
Optical Distance-to-Fault Module, 1550 nm, Single Mode
USB Flash Drive
External Charger for Li-lon Batteries
optional accessories
Backpack and Transit Case
67135
760-243-R
Anritsu Backpack (For Handheld Instrument and PC)
Large Transit Case with Wheels and Handle
Directional Antennas
Part Number
Description
2000-1411-R
822-900 MHz, N(f), 10 dBd, Yagi
2000-1412-R
885-975 MHz, N(f), 10 dBd, Yagi
2000-1413-R
1710-1880 MHz, N(f), 10 dBd. Yagi
2000-1414-R
1850-1990 MHz, N(f), 9.3 dBd, Yagi
2000-1415-R
2400-2500 MHz, N(f), 10 dBd, Yagi
2000-1416-R
1920-2170 MHz, N(f), 10 dBd, Yagi
2000-1519
500 MHz to 3 GHz, log periodic
2000-1200
806-866 MHz, SMA(m), 50 Ω
2000-1473
870-960 MHz, SMA(m), 50 Ω
2000-1035
896-941 MHz, SMA (m), 50 Ω (1/4 wave)
2000-1030
1710 to 1880 MHz, SMA(m), 50 Ω (1/2 wave)
2000-1474
1710 to 1880 MHz with knuckle elbow (1/2 wave)
Portable Antennas
2000-1031-R
2000-1475
2000-1032-R
2000-1361
61532
1850 to 1990 MHz, SMA(m), 50 Ω (1/2 wave)
1920 to 1980 MHz and 2110 to 2170 MHz, SMA(m), 50 Ω
2400 to 2500 MHz, SMA(m), 50 Ω (1/2 wave)
2400 to 2500, 5000 to 6000 MHz, SMA(m), 50 Ω
Antenna Kit (Consists of: 2000-1030, 2000-1031, 2000-1032-R,
2000-1200, 2000-1035, 2000-1361, and carrying pouch)
Bandpass Filters
1030-114-R
806-869 MHz, N(m) - SMA(f), 50 Ω
1030-109-R
824 - 849 MHz, N(m) - SMA (f), 50 Ω
1030-110-R
880 - 915 MHz, N(m) - SMA (f), 50 Ω
1030-105-R
890-915 MHz Band, 0.41 dB loss, N(m) - SMA(f), 50 Ω
1030-111-R
1850 - 1910 MHz, N(m) - SMA (f), 50 Ω
1030-106-R
1710-1790 MHz Band, 0.34 dB loss, N(m) - SMA(f), 50 Ω
1030-107-R
1910-1990 MHz Band, 0.41 dB loss, N(m) - SMA(f), 50 Ω
1030-112-R
2400 - 2484 MHz, N(m) - SMA (f), 50 Ω
1030-155-R
2500-2700 MHz, N(m) – N(f), 50 Ω
3-1010-122
20 dB, 5 W, DC to 12.4 GHz, N(m)-N(f)
42N50-20
20 dB, 5 W, DC to 18 GHz, N(m) - N(f)
42N50A-30
30 dB, 5 W, DC to 18 GHz, N(m) - N(f)
3-1010-123
30 dB, 50 W, DC to 8.5 GHz, N(m)-N(f)
1010-127-R
30 dB, 150 W, DC to 3 GHz, N(m) - N(f)
3-1010-124
40 dB, 100 W, DC to 8.5 GHz, N(m)-N(f), Uni-directional
Attenuators
1010-121
1010-128-R
40 dB, 100 W, DC to 18 GHz, N(m)-N(f), Uni-directional
40 dB, 150 W, DC to 3 GHz, N(m) - N(f)
15
Anritsu Corporation
5-1-1 Onna, Atsugi-shi, Kanagawa, 243-8555 Japan
Phone: +81-46-223-1111
Fax: +81-46-296-1264
• U.S.A.
Anritsu Company
• Brazil
Anritsu Electrônica Ltda.
• India
Anritsu Pte. Ltd.
India Branch Office
3rd Floor, Shri Lakshminarayan Niwas,
#2726, 80 ft Road, HAL 3rd Stage, Bangalore - 560 075, India
Phone: +91-80-4058-1300
Fax: +91-80-4058-1301
Teknobulevardi 3-5, FI-01530 Vantaa, Finland
Phone: +358-20-741-8100
Fax: +358-20-741-8111
• P. R. China (Hong Kong)
Anritsu Company Ltd.
• Denmark
Anritsu A/S
Units 4 & 5, 28th Floor, Greenfield Tower, Concordia Plaza,
No. 1 Science Museum Road, Tsim Sha Tsui East,
Kowloon, Hong Kong, P.R. China
Phone: +852-2301-4980
Fax: +852-2301-3545
Kirkebjerg Allé 90 DK-2605 Brøndby, Denmark
Phone: +45-72112200
Fax: +45-72112210
Praca Amadeu Amaral, 27-1 Andar
01327-010 - Paraiso, São Paulo, Brazil
Phone: +55-11-3283-2511
Fax: +55-11-3886940
• P. R. China (Beijing)
Anritsu Company Ltd.
Beijing Representative Office
• Spain
Anritsu EMEA Ltd.
Oficina de Representación en España
• Mexico
Anritsu Company, S.A. de C.V.
Room 2008, Beijing Fortune Building,
No. 5 , Dong-San-Huan Bei Road,
Chao-Yang District, Beijing 100004, P.R. China
Phone: +86-10-6590-9230
Fax: +86-10-6590-9235
Edificio Veganova
Avda de la Vega, n 1 (edf 8, pl1, of 8)
28108 ALCOBENDAS - Madrid, Spain
Phone: +34-914905761
Fax: +34-914905762
o
Av. Ejército Nacional No. 579 Piso 9, Col. Granada
11520 México, D.F., México
Phone: +52-55-1101-2370
Fax: +52-55-5254-3147
• U.K.
Anritsu EMEA Ltd.
200 Capability Green, Luton, Bedfordshire LU1 3LU, U.K.
Phone: +44-1582-433280
Fax: +44-1582-731303
Nemetschek Haus, Konrad-Zuse-Platz 1
81829 München, Germany
Phone: +49 (0) 89 442308-0
Fax: +49 (0) 89 442308-55
60 Alexandra Terrace, #02-08, The Comtech (Lobby A)
Singapore 118502
Phone: +65-6282-2400
Fax: +65-6282-2533
• Finland
Anritsu AB
700 Silver Seven Road, Suite 120, Kanata,
Ontario K2V 1C3, Canada
Phone: +1-613-591-2003
Fax: +1-613-591-1006
• Germany
Anritsu GmbH
Via Elio Vittorini, 129, 00144 Roma, Italy
Phone: +39-06-509-9711
Fax: +39-06-502-2425
Borgafjordsgatan 13, 164 40 Kista, Sweden
Phone: +46-8-534-707-00
Fax: +46-8-534-707-30
• Canada
Anritsu Electronics Ltd.
16/18 Avenue du Québec-SILIC 720
91961 COURTABOEUF CEDEX, France
Phone: +33-1-60-92-15-50
Fax: +33-1-64-46-10-65
• Singapore
Anritsu Pte. Ltd.
• Sweden
Anritsu AB
1155 East Collins Boulevard, Suite 100,
Richardson, Texas 75081 U.S.A.
Toll Free: 1-800-ANRITSU (267-4878)
Phone: +1-972-644-1777
Fax: +1-972-671-1877
• France
Anritsu S.A.
• Italy
Anritsu S.p.A.
• Korea
Anritsu Corporation, Ltd.
• Russia
Anritsu EMEA Ltd.
Representation Office in Russia
8F Hyunjuk Bldg. 832-41, Yeoksam-Dong,
Kangnam-ku, Seoul, 135-080, Korea
Phone: +82-2-553-6603
Fax: +82-2-553-6604
Tverskaya str. 16/2, bld. 1, 7th floor.
Russia, 125009, Moscow
Phone: +7-495-363-1694
Fax: +7-495-935-8962
• Australia
Anritsu Pty Ltd.
• United Arab Emirates
Anritsu EMEA Ltd.
Dubai Liaison Office
P O Box 500413 - Dubai Internet City
Al Thuraya Building, Tower 1, Suite 701, 7th Floor
Dubai, United Arab Emirates
Phone: +971-4-3670352
Fax: +971-4-3688460
Unit 21/270 Ferntree Gully Road, Notting Hill
Victoria, 3168, Australia
Phone: +61-3-9558-8177
Fax: +61-3-9558-8255
• Taiwan
Anritsu Company Inc.
7F, No. 316, Sec. 1, Neihu Rd., Taipei 114, Taiwan
Phone: +886-2-8751-1816
Fax: +886-2-8751-1817
The Master Users Group is an organization dedicated to providing training, technical support, networking opportunities
and links to Master product development teams. As a member you will receive the Insite Quarterly Newsletter with user
stories, measurement tips, new product news and more.
Visit us to register today: www.anritsu.us/smiusignup
To receive a quote to purchase a product or order accessories visit our online ordering site: www.ShopAnritsu.com
Training at Anritsu
Anritsu has designed courses to help you stay up to date with technologies important to your job.
For available training courses visit: www.us.anritsu.com/training
®Anritsu All trademarks are registered trademarks of
their respective companies. Data subject to change
without notice. For the most recent specifications visit:
www.us.anritsu.com
Catalog No. 11410-00516, Rev. A Printed in United States 2009-08
©2009-08 Anritsu Company. All Rights Reserved.
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF