WAT-902H ULTIMATE 2 3
Monochrome CCD Camera
Guide to the Safety Symbols
The meanings of the symbols used in this operation manual are:
WAT-902H2 ULTIMATE
WAT-902H3 ULTIMATE
Operation Manual
This Operation Manual covers safety, camera functions, installation and the
correct operating procedure for the WAT-902H2/3 ULTIMATE. First, we
ask you to read this Operation Manual thoroughly, then install and operate
the WAT-902H2/3 ULTIMATE as advised. In addition, for future reference,
we also advise safe keeping of this manual.
Please contact the distributor or dealer from which the WAT-902H2/3
ULTIMATE was purchased, if you do not understand the installation,
operation or safety instructions laid out in this manual. Not understanding
the contents of the Operation Manual sufficiently may cause damage to the
camera.
Cautions for Safety
WAT-902H2/3 ULTIMATE is designed to be used safely; however, it may
lead to physical accident caused by fire and electric shock if not used
correctly. Therefore, please keep and read the“Cautions for Safety”for
protection against accidents.
Danger
Warning
When you do not adhere to or take notice of the “Danger”
sign, it may lead to serious accident such as death or injury
caused by fire or electric shock.
Warning
When you do not adhere to or take notice of the “Warning”
sign, it may cause severe damage such as a physical injury.
Caution
When you do not adhere to or take notice of the “Caution”
sign, it may incur injury and cause damage to peripheral objects
in the immediate surroundings.
About EMC
The WAT-902H2/3 ULTIMATE is in conformity with EMC test standards
carried out by authorized organizations in Japan.
EIA
CCIR
/
FCC Part15 class B
EN61000-6-3/EN50130-4
※Do not modify the WAT-902H2/3 ULTIMATE. A modified camera may
not conform to EMC test standards.
Problems and Trouble Shooting
If any of the following problems occur when using the WAT-902H2/3
ULTIMATE,
• Do not disassemble and/or modify the WAT-902H2/3
ULTIMATE.
• An optimal picture cannot be obtained, after checking that all the cables
and connections are correctly in place
• Do not operate the WAT-902H2/3 ULTIMATE with wet
hands.
• Smoke or any unusual odor emerges from the WAT-902H2/3 ULTIMATE.
• Use only the AD-901 or equivalent power adaptor for the
WAT-902H2/3 ULTIMATE.
The recommended voltage is DC+12V±10%
• Do not expose the WAT-902H2/3 ULTIMATE to wetness or
high moisture conditions.
The WAT-902H2/3 ULTIMATE is designed and approved for
indoor use only. The WAT-902H2/3 ULTIMATE is not waterresistant or waterproof. If the location of the camera is
outdoors or in an outdoor like environment, we recommend
that you use an outdoor camera housing.
• Protect the WAT-902H2/3 ULTIMATE from condensation.
Keep the WAT-902H2/3 ULTIMATE dry at all times, during
storage and operation.
• Should the camera not work properly, switch off the power
immediately. Please check the camera according to the
“Problems and Trouble Shooting”section.
Caution
Danger
• An object becomes embedded or a quantity of liquid seeps into the
camera housing
• More than the recommended voltage or/and amperage has been applied
to the WAT-902H2/3 ULTIMATE by mistake
• Anything unusual occurring to any equipment connected to the WAT902H2/3 ULTIMATE.
Disconnect the camera immediately according to the following procedures:
①Switch off the main power supply to the camera.
②Remove the power and video cables connected to the WAT-902H2/3
ULTIMATE.
③Contact the distributor or dealer from which the WAT-902H2/3
ULTIMATE was purchased.
Contents
Using the contents figures below, check to make sure all parts are present
before use.
• Avoid the striking of hard objects or dropping the WAT902H2/3 ULTIMATE.
The WAT-902H2/3 ULTIMATE uses high quality electrical
parts and precision components.
• Do not connect any power supply directly to the video out
terminal of the unit.
Do not connect the WAT-902H2/3 ULTIMATE with any
monitor using a video/power single transmission terminal. The
WAT-902H2/3 ULTIMATE is not designed for use with this
type of equipment. We also advise you to read the operation
manual of the monitor you plan to use before any connections
are made.
• Do not install the WAT-902H2/3 ULTIMATE in a position
subject to direct sunlight.
Sunlight shinning directly onto the WAT-902H2/3 ULTIMATE
lens can cause damage to the CCD.
• Select a stable place for installation of the WAT-902H2/3
ULTIMATE.
Use a support of durable strength around an installation
position on a ceiling or wall when a camera stand or tripod is
used.
• Do not move the WAT-902H2/3 ULTIMATE with the cables
connected.
Before moving the WAT-902H2/3 ULTIMATE, always
remove the video cable and power cable from the rear of the
camera first.
• Avoid using the WAT-902H2/3 ULTIMATE near any strong
electromagnetic field.
After installing into main equipment, if the WAT-902H2/3
ULTIMATE is exposed to electromagnetic waves causing the
monitored image to become distorted, we recommend the
camera be shielded by appropriate protective casing.
Lens Mount Cap
WAT-902H2/3 ULTIMATE
Hex. Wrench
Description of Parts
③
⑥
④
①
②
⑤
⑦
⑧
⑨
⑪
⑫
⑬
⑭
⑮
⑩
①CCD FRONT FACE
・The light receiving face of the CCD camera
(Dirt, water or oil deposits on the CCD will cause an unclear picture on the
monitor. Attach the lens cap to protect the lens and CCD from
contamination and damage.)
②LENS MOUNT
・Mount for the lens (Thread type)
Set-up and Operation
③IRIS LEVEL VOLUME
・By controlling the volume, the iris level of a DC iris lens can be adjusted.
④FOCUSING ADJUSTMENT SCREWS
・There are 3 hex. adjustment screws each placed at intervals of 120゜for
fine focusing of the lens.
⑤AUTO-IRIS SOCKET
・This socket is for a video or DC auto-iris lens cable connector.
(Video/DC: Auto selected by the camera)
⑥TRIPOD MOUNTING SCREW HOLES
・Mounting holes for stands. The size of these threads are 1/4”, 20
threads, 4.5±0.2mm, which is the same as any standard camera tripod
(U1/4”).
⑦CAMERA BASE
・The camera base has a thread for fixing to a standard tripod and four
M3 size holes for additional easy fixing.
⑧VIDEO OUT (BNC)
・The terminal for composite video signal output
⑨GAMMA CORRECTION SWITCH
・Three gamma values are selectable, 1.0, 0.45, 0.35.
⑩POWER IN
・The terminal designed for connection with the DC-plug of the power
adaptor
⑪MGC VOLUME ADJUSTING
・The volume for setting manual gain control
⑮AE MODE CONTROL
・The switch for the shutter speed mode control according to the object
Power Supply
If any other power adaptor besides the AD-901 is used, please use a
stabilized power adaptor designed for DC+12V ± 10%, with a current
capacity of more than 250mA.
Use the optional DC plug if the shape or polarity of the DC plug of the
power adaptor to be used is not compatible with the camera (See the
drawing on the right).
Caution
DC+12V
Before connecting the auto-iris lens, please make sure that the pin
configuration is correct by confirming with the following table below. If the
configuration of your iris connector is different from the following, the plug
and pins will need to be rewired.
③
①
EIAJ Video
Auto-iris Lens
Arrangement
Pin No.
①
②
③
④
Power
Not used
Iris signals
Common (GND)
5) Insert the power plug of the power adaptor into ⑩POWER IN on the
back
panel of the WAT-902H2/3 ULTIMATE. Confirm that the power
adaptor is not connected to the power supply before insertion of the
power plug into ⑩POWER IN.
6) Turn on the power to the WAT-902H2/3 ULTIMATE, monitor and all
other allied equipment. When a picture cannot be obtained on the
monitor, or a strong smell of burning is present, or smoke is visible, check
and follow the procedure mentioned in the Problems and Trouble
Shooting section.
DC Auto-iris Lens
Adjust the focus and iris to the best position
on the lens.
Adjust the focus on the lens.
Adjust the iris level on the camera, then
adjust the focus on the lens. See below.
Iris Level Adjustment (for DC auto-iris lenses only)
Adjust ③IRIS LEVEL VOLUME placed on the side
of the unit until an acceptable light level is attained.
No change will occur if a video iris lens or manual
iris lens is fitted.
EIAJ DC
Auto-iris Lens
Arrangement
OPEN
LEVEL
8) Select any required gamma by the ⑨GAMMA CORRECTION SWITCH.
Mode
Gamma
Effect
OFF
1.0
Required for image processing such as
data storage for PCs and for FA.
LO
0.45
Standard setting for using TVs and
Monitors. Natural images can be obtained
in dark areas.
HI
0.35
Dark areas can be lightened and bright
areas can be reduced.
※Select LO position for normal use. In a low light environment or dark
viewing, HI mode is recommended
9) Select any required gain control by the ⑫AGC/MGC SELECTION
SWITCH.
Mode
Range
Effect
MGC
5∼60dB
・In a low light environment, when
illumination of the object is important,
increase the manual gain. Lower the
gain control for a clearer picture with
less noise. (Factory automation or Image
processing)
AGC HI
5∼60dB
・When minimum illumination is more
important than the S/N ratio
(Surveillance in a low light environment)
AGC LO
5∼32dB
・When SN ratio is more important than
minimum illumination.
・When adequate lighting is present or a
stable lighting condition is available.
Control −
Control +
Drive +
Drive −
Camera Base
There is a tripod mounting screw
hole as shown in the diagram on
the right .
In addition, there are 4 corners
holes M3 size and one φ5 for
stability.
CLOSED
※When an auto-iris lens is used, set ⑫AGC/MGC
SELECTION SWITCH to AGC off and set ⑮AE
MODE CONTROL to any position other than 8 (EI). If AGC and E.I are
needed, change the switch settings according to your requirements.
COMMON(GND)
Auto-iris Lens
②
4) Connect ⑧VIDEO OUT on the WAT-902H2/3 ULTIMATE with the
monitor, using a coaxial cable with 75 Ω impedance, such as an
RG-58/U or an RG-6/U. Select a monitor with the same television
system as the WAT-902H2/3 ULTIMATE: EIA or CCIR. A monitor with
more than 600TV lines is recommended.
Video Auto-iris Lens
⑭ELECTRONIC SHUTTER ON/OFF SWITCH
・The switch for the selecting electronic shutter mode
④
3) Connect the iris cable to ⑤AUTO-IRIS SOCKET on the WAT-902H2/3
ULTIMATE when an auto-iris lens is being used.
Manual Lens
⑬BACK LIGHT
・The switch for back light compensation
The wiring on the connector must be exact.
Be careful not to touch the other terminal while wiring.
Protect the wiring portion by using insulation tape
after wiring. If the above care and attention is not
adhered to, damage to the WAT-902H2/3 ULTIMATE
and power adaptor may occur or may cause fire.
2) Remove the lens mount cap from the WAT-902H2/3 ULTIMATE and
attach the CS-mount lens. Use the optional C-mount adaptor
(30CMA-R) when a C-mount lens is used.
7) Focusing: Follow the operations mentioned below while looking at the
screen on the monitor for focusing.
⑫AGC/MGC SELECTION SWITCH
・Switch for setting AGC HI、LO or MGC
Warning
1) Ensure that the power to the WAT-902H2/3 ULTIMATE and the
peripheral equipment is turned off before making any connections.
10) Set the gain to any required environment by ⑪MGC VOLUME
ADJUSTING. Manually adjusted in a range between 5 to 60dB. In a low
light environment, when illumination of the object is important, increase
the manual gain. Lower the gain control for a clearer picture with less
noise.
11) Select any required back light area by ⑬BACK LIGHT to one of its 4
positions.
Switch
Area
ON
Specifications
WAT-902H2 ULTIMATE
WAT-902H2 ULTIMATE
Model
1. Default
1
2
ON
2. Center
1
2
Pick-up Element
Unit Cell Size
Minimum Illumination
3. Lower
2
WAT-902H3 ULTIMATE
4. Center + Lower
13) Select any required shutter speed by the ⑮AE MODE CONTROL to one
of its 10 positions.
0
1
FL
ES
2
3
4
5
6
7
8
9
ES
ES
ES
ES
ES
ES
EI: OFF
EI: FL
6.5um(H)×6.25um(V)
0.0002lx. F1.4
2
12) Set the shutter mode by ⑭ELECTRONIC SHUTTER ON/OFF SWITCH
When shutter mode is OFF, fix the shutter speed to EIA1/60,
CCIR1/50. When shutter mode is ON, select the shutter speed mode by
⑮AE MODE CONTROL.
Mode
6.35um(H)×7.4um(V)
WAT-902H2 ULTIMATE/WAT-902H3 ULTIMATE
1
No.
Unit Cell Size
CCIR
1/3 inch interline transfer CCD image sensor
Minimum Illumination
ON
8.6um(H)×8.3um(V)
0.0001lx. F1.4
EIA
Pick-up Element
1
8.4um(H)×9.8um(V)
WAT-902H3 ULTIMATE
Model
ON
EIA
CCIR
1/2 inch interline transfer CCD image sensor
Shutter Speeds (Sec.)
EIA
CCIR
1/100
1/120
1/250
1/500
1/1000
1/2000
1/5000
1/10000
1/100000
1/60-1/100000
1/50-1/100000
1/100-1/100000
1/120-1/100000
※In EI mode, intense light may leave a trail on the screen longitude. This
smearing is a natural phenomenon and is not due to equipment failure.
Options
To purchase these options, please contact the distributor or dealer from
which you purchased the WAT-902H2/3 ULTIMATE.
AC Adaptor (AD-901)
The recommended AC adaptor for
the WAT-902H2/3 ULTIMATE for
a constant and stable power
supply.
C-mount Adaptor (30CMA-R)
This lens mount adaptor is used
to convert a CS-mount to a Cmount.
Mini Stand (MS50)
A convenient stand for the
WAT-902H2/3 ULTIMATE. With
this stand, the camera can be
adjusted to any desired angle.
Model
Number of
Total Pixels
Number of
Effective Pixels
Scanning System
Sync. System
Video Output
ON
AGC
OFF
Back Light
Compensation
Resolution (H)
S/N
Auto-iris
Gamma
Characteristics
OFF
FL
AE Mode
EI: OFF
EI: FL
Power Supply
Power Consumption
Operating
Temperature
Operating Humidity
Storage
Temperature
Storage Humidity
Size
Lens Mount
Weight
Use this connector if the iris
connector of your lens does not fit
the WAT-902H2/3 ULTIMATE
auto-iris socket.
WAT-902H3 ULTIMATE
EIA
CCIR
811(H)×508(V)
795(H)×596(V)
768(H)×494(V)
752(H)×582(V)
2:1 interlace
Internal
Composite video, 1.0V(p-p) 75Ω (Unbalanced)
HI: 5∼60dB/LO: 5∼32dB
5∼60dB(MGC)
①OFF(Default) ②Center ③Lower ④Center+Lower
570TVL
More than 50dB (AGC=5dB, γ off)
Video/DC (Auto-Select)
HI(γ≒0.3)/LO(γ≒0.45)/OFF(γ≒1.0)
1/60 sec.
1/100 sec.
1/50 sec.
1/120 sec.
1/250、1/500、1/1000、1/2000
1/5000、1/10000、1/100000 sec.
1/60-100000 sec.
1/50-1/100000sec.
1/100-100000 sec.
1/120-100000sec.
DC12V±10%
1.32W
-10∼40℃
Less than 95% RH (Without condensation)
-30∼70℃
Less than 95% RH (Without condensation)
35.5×40×63 (mm)
CS-mount
98g
• Design and specifications are subject to change without notice.
• Watec is not responsible for any inconvenience or the attendant damages
to the video and monitoring recording equipment caused by misuse, misoperation or improper wiring of our equipment.
• If for any reason the WAT-902H2/3 ULTIMATE does not work properly,
or if you have any questions regarding installation or operation, please
contact the distributor or dealer from which it was purchased.
Contact information
Watec Co., Ltd.
Add.:
Auto-iris Plug (AIC-G)
ES
WAT-902H2 ULTIMATE
254-2 Nihonkoku, Daihoji, Tsuruoka- Shi,
Yamagata-Ken, 997-0017 Japan
+81-235-23-4400 FAX: +81-235-23-4409
TEL:
Email: info-o@watec.co.jp
URL: http://www.watec.net