Poseidon 1250 FL en
Poseidon 1250
HW group
Product description
Poseidon model 1250
Measurement of temperature and other sensors over the network.
The Poseidon model 1250 send alert when sensor value
gets out of defined range. Alert can be Email, SNMP Trap
or SMS. Embedded web server for setup and also
network M2M protocols (SNMP, XML, Modbus/TCP).
Up to 40 sensors can be connected by two
bus systems and dry contact inputs.
3x inputs to connect contacts
RJ12 1-Wire bus up to 10 sensors
(temperature or humidity) up to 10 meters
RJ45 RS-485 bus up to 31 sensors (temperature, humidity, voltage 0 to
5V, current 0 to 20mA, impulses, power, current consumption and air-flow) over distance of up to 1000
meters.
Application examples
Server rooms / Datacenters (humidity, door, motion detector, hazardous gas)
Storage services, cold storages, freezers and refrigerator (food industry, pharmacy)
Monitoring of network devices (microwave connections, AP, distribution boxes)
Supervising of air-conditioning – temperature and condensed water leakage from
air-conditioning units.
Monitoring of environment in UPS, back-up power supply and Diesel-system
rooms and Diesel-engines over SNMP
Extensive buildings – heating optimization (temperature measuring), stop contacts,
EPS)
EZS,
Providing external data to SCADA systems
Monitoring ATM, terminals, transmitters
Value sensors
Temperature (up to 42 sensors, temperature range -55 °C to +640 °C, Sensor-unit distance up to
1 000 meters
Humidity (up to 25 sensors, maximum sensor distance: 1 000 meters)
General sensors:
Voltage (0 to 10V and 110/230V)
Air flow
Declination / Inclination
Current (0 to 20mA and 230V)
Motion and location
Closing/opening door
Flood (surface detector)
Smoke and gas
General contact
www.HW-group.com
Poseidon 1250
HW group
Features
Graphical WWW interface for setup.
Poseidon model 1250
No special SW necessary
Dry Contact Inputs:
Outputs (via RS-232):
Sensors
 1W bus (local area):
 RS485 bus (up to 1000m):
One Poseidon 1250 monitors up to 42 external sensors.
Alarm state reporting - Email, SNMP Trap, SMS (local
GSM morem G10 required or SW application PD Trigger).
Large sensor portfolio, from economical to professional
industrial sensors. Sensor distance up to 1000 meters.
SNMP:
Alarm alerts by e-mail:
Internal flash logger:
GSM modem (SMS alerts):
Direct control two external relays.
Opened communication protocols (SNMP, XML,
Modbus/TCP)
3
2
10
31
Yes
Yes
No
Yes
Supported programs and utilities (PD Trigger, HWg-PDMS, CapTemp and others)
SDK (Software Development Kit) SW development libraries + examples (VB, Delphi, Java, C, C# etc.)
Third party SNM software applications:
LoriotPro, HP, OpenView, Nagios, IBM, Tivoli, SNMPc, MRTG, NMS dashboard
Summary
Network communication protocols
Configuration
 Web (HTML)
 Serial port RS-232 (terminal)
 XML
 WEB graphical interface (Flash Setup)
 Modbus/TCP
 TELNET (TCP Setup)
 SNMP
 UDP broadcast (UDP Setup)
 TCP/IP, UDP/IP
Status indicators
 LED: Alarm, Sensor, Power, Link
Alarm alert
 E-mail
Outputs
 2 outputs for relay control
 SNMP Trap
(Can’t be used together with GSM modem)
 SMS
DTR
Modbus/TCP
RTS
Pt100
WEB (HTML)
Digital
Inputs
INTERNET
(INTRANET)
12V DC
Digital
Outputs
Poseidon 1250
Industrial bus
RJ45
er
t
Alar
m
Email
Alar
m
al
Temp-485-Pt100
Temperature
Humidity
HTemp-485
Temp-485
er
t
SNMP trap
RS-485
SNMP
Up to 20m
XML
Up to 1.000m
Ethernet
Power
al
Temp-485
www.HW-group.com
Poseidon 1250
HW group
Evaluation kits
Poseidon 1250 Tset
Poseidon unit, model 1250 [600 006]
Temperature sensor – Temp- 1Wire [600 005]
Door contact [600 119]
Power adaptor [600 080]
Manual – “Starting Guide” – Poseidon 1250 Tset”
CD with documentation, FirmWare versions, test
utilities and others SW.
Poseidon 1250 THset
Poseidon unit, model 1250 [600 006]
HTemp-485 temperature/humidity sensor [600
106]

Sensor RJ45 MIDDLE cable [600 233]
Door contact [600 119]
Power adaptor [600 080]
Manual – “Starting Guide” – Poseidon 1250 Tset”
CD with documentation, FirmWare versions, test
utilities and others SW.
OID
Product name
Product description
600 006
Poseidon model 1250
Poseidon unit 1250
600 042
600 043
Poseidon 1250 Tset
Poseidon 1250 THset
Start set Poseidon 1250, power adaptor, CD, temperature sensor
Start set model 1250, power adaptor, temperature and humidity sensors
Other accessories
600 080
600 251
Wall power adaptor 12V
Back-Up power supply 12V
Power adaptor 0.5A for EU plug (UK = 600 082, US = 600 081)
Power supply 12V / 0.4 A backed up by accumulator
600 023
2x Wall Bracket “A” size
Lateral “L” plates, for wall mounting.
Poseidon T-Box
600 040
Temp-1Wire 1m
600 242
Poseidon S-Hub
600 041
Temp-485-Pt100 „Box“
600 113
Temp-485
600 105
www.HW-group.com
Poseidon 1250
HW group
Sensors for Poseidon 1250
IT bus (RJ12)
Up to 10 sensors connected en bloc, maximum total bus length is 10m, but type 1-Wire
600 005
Temp-1Wire 3m
Temperature sensor, accuracy ± 0.5°C, cable 3m, (1m=600 242)
600 056
600 279
Temp-1Wire 10m
Humid-1Wire 3m
Temperature sensor, accuracy ± 0.5°C, connecting cable 3m
Humidity sensor, connecting cable 3m (1m = 600 278)
600 040
600 280
Poseidon T-Box
Poseidon T-Box2
Hub for connection of 5 RJ12 sensors to the unit
Hub for connection of 2 RJ12 sensors to the unit cable 3m
Industrial bus (RJ45)
Up to 31 sensors connected in total, maximum total bus length is 1000m, but type RS-485
600 041
600 233
600 044
Poseidon S-Hub
Sensor RJ45 MIDDLE cable
Poseidon B-Cable
Hub for connection up to 8 sensors over RS-485 bus (8x RJ45)
Cable of 0.5m (RJ45 plug / 4 wires for the terminal block)
Converter for the RS-485 bus RJ45 socket / 4 terminal pins (A,B,+,-)
600 273
Spider-485
Connects up to 4x 1-Wire (RJ12) sensor over RS 485 bus
600 105
600 106
600 116
600 113
600 114
600 112
Temp-485
HTemp-485
Sens-485-UI
Temp-485-Pt100 „Box“
Temp-485-Pt100 „Cable“
Temp-485-2xPt100 „DIN“
Temperature sensor – indoor vertical wall mounting
Temperature and humidity sensor – indoor vertical wall mounting
Voltage (0..15V) and current sensor (0..25mA), DIN rail version
Platinum temperature sensor, accuracy: ± 0.15 °C, IP65 for outdoor use
Pt100 – platinum temperature sensor, cable 2m, accuracy: ± 0.2 °C
Converter for 2 external temp. sensors Pt100, mounting on DIN rail
Digital outputs (DB9)
Two digital outputs RTS and DTR, controlled over serial interface RS-232.
600 244
600 237
P1250 RC (Relay Cable)
PowerEgg
Converter for two relays (12V coil) for the Poseidon 1250 over RS-232
Control of AC output (110 up to 230V)
600 085
DIN Rail Relay 2s
Switch relay on DIN rail – 10A / LED indicator
Digital inputs (terminal block)
Three inputs for the connection of ‘Dry Contact“ sensors
600 120
3 Door Contacts
Detector of opening/closing door (packet of 3 pieces)
600 237
PowerEgg
Detection of AC voltage (110/230V), controllable AC output (110/230V)
600 240
600 235
600 239
600 236
600 304
Flood detector
Smoke detector
Gas Leak Detector 12V
Motion PIR detector
AirFlow SL5101
Flood detector
Ionic smoke detector
Flammable gas detector
Infrared motion detector
Air flow speed digital adjustable detector
www.HW-group.com
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising