IFR / Aeroflex FM/AM-1900 Specification Sheet

IFR / Aeroflex FM/AM-1900 Specification Sheet
www.avionteq.com
IFR-1900 CSA
UWC-136 Digital PCS Radio Test Set
Wireless - Radio Test Sets
http://www.avionteq.com/IFR-Aeroflex-FM-AM-1900-CSA-Communication-Service-Monitor.aspx
Engineered for maximum
performance, the
IFR-1900 CSA is an
all in one PCS solution
for today’s dual
band/dual mode mobile
and base station
equipment
The industry accepted simulator for
TIA/EIA-136 conformance testing
Tri-Band, 400/800 MHz and
1900 MHz PCS test capable
Comprehensive TIA/EIA-136
conformance testing
Analog and digital authentication
compliance testing option
TIA/EIA-136 hyperband handoff
Fully automated remote testing
ability with RS-232 or IEEE-488
(GPIB) interfaces
Intuitive test set up screens for
easy “Guided” user testing
VSELP and ACELP vocoder
functions allow verification of voice
quality
Full featured 2 GHz service monitor
with spectrum analyzer and
tracking generator
Standard constellation IQ display
for quick assessment of digital
mobile or base station transmitter
modulation
Fully Featured TIA/EIA-136 (TDMA) Test
Solution
The IFR-1900 CSA provides you with the
industry’s only accepted test solution for
TIA/EIA-136 analysis, including critical
adjacent power measurements and power
measurements down to -40 dBm, which
allows the user to test the base station
without taking it off-line.
It is capable of performing the critical
dual-mode analog/digital authentication
and protocol compliance tests for
TIA/EIA-136 dual mode mobiles.
As for flexibility, the IFR-1900 CSA
provides the capability to perform both
mobile and base station conformance
testing. And with the VSELP and ACELP
vocoder technology as standard features,
the IFR-1900 CSA can handle today’s
latest technology.
The IFR-1900 CSA comes with a wide
array of application software options. The
AC1036 Protocol Conformance Test
Software provides an excellent way to verify
software conformance of TIA/EIA-136
mobiles.
Other applications software
supports automated tests for the most
widely used base station applications.
AMPS Solutions
Engineered to be a true dual-mode test
solution, the IFR-1900 CSA also
incorporates AMPS and NAMPS mobile
and base station compliance test features.
Full AMPS testing modes are available with the
IFR-1900 CSA
Automatic test routines and user
defined print outs enhance manual mode
testing for both mobiles and base stations.
Open control channel simulations, voice
channel signaling, home/roam condition,
home SID, SAT, DSAT, DST, DCC, SINAD
reference points, RF power windows, and
other AMPS/NAMPS functions and
signaling routines allow complete AMPS
and NAMPS system testing.
A Full Complement of Service Monitor
Functions to 2 GHz.
The IFR-1900 CSA gives you full
frequency domain analysis to 2 GHz with a
fully featured spectrum analyzer and
tracking generator built-in.
The IFR-1900 CSA also offers a full
complement of standard service monitor
features including a full span digitized
oscilloscope to 1 MHz, DVM and SINAD
functions, frequency and channel tables,
selectable IF filters, and a wide variety of
displays.
The IFR-1900 CSA gives you full featured service
monitor functions
http://www.ifrinternational.com
IFR-1900 CSA
1
IFR-1900 CSA
In addition to the 2 GHz RF generator,
the IFR-1900 CSA also provides full
audio/data generator capabilities, full level
control and measurement facilities and
precision power control features for
enhanced sensitivity and high accuracy
testing needs.
Analog paging encoding/decoding,
DTMF, tone coded squelch, digital squelch,
AM modulation/demodulation along with
two separate AF generators and cross band
duplex gives added test versatility in a
variety of wireless systems.
Software Options Make Complex
Testing Simple
As with every IFR test set, you get the
advantage of IFR applications engineering
support.
Our comprehensive portfolio of
application software options are designed
to automate and expand the functionality
of your instrument.
Plus, on-going software support means
that you can easily upgrade your
IFR-1900 CSA when test and service
requirements change.
AC1009W - EasySpanTM is a Windowsbased software utility which extracts
spectrum analyzer and tracking generator
traces from the IFR-1900 CSA.
AC1017 - AutoCell-Series II is a
comprehensive
program
for
FCC
compliance testing of Lucent Series II cell
sites.
AC1019 - EasySweepTM is a swept
measurement utility designed to test
antennas and transmission lines.
AC1020D - AutoCell NTD provides
automated testing of Northern Telecom cell
sites.
AC1021 - CellScanTM cellular utility
software simplifies combiner alignment,
monitoring RF levels and base stations on
DAMPS, NT400 or PCS cellular channel
sets.
AC1027 - AutoCell-882/884 is an
autotest
program
for
performing
acceptance
tests
on
Ericsson
884/882/882D/882M/882DM
base
stations.
Dynamic IQ Constellation Display
Simplifies Analysis
The IFR-1900 CSA provides you with a
dynamic constellation display for precise
RF modulation analysis of DQPSK digitally
modulated waveforms from 10 MHz to
2010 MHz. This unique IFR-1900 CSA
feature gives a near real time display for
testing and troubleshooting, an ability that
points out the cause of the trouble in digital
radios.
EXTERNAL
Generator IF Output Frequency Range
88 MHz to 90 MHz
Level Range
-30 dBm to +25 dBm into 50 Ω
Residual FM
<10 Hz RMS
Non-Harmonics
<-50 dBc
Nominal Input Frequency for Generator IF In
90 MHz
Input Level
-26 dBm to +28 dBm into 50 Ω
Signal Bandwidth
8.5 MHz
IQ Constellation display allows for comprehensive
digital modulation testing
Complex Functionality Made Easy
Even with its elaborate capabilities, the
IFR-1900 CSA was developed to execute
complex tests simply and with minimal
operator training.
Using field-proven front panel and user
man-machine interfaces, the IFR-1900 CSA
gives you the performance and ease-of-use
features that reduces your testing and
training time.
Its test macro command programming
language (TMAC) can be easily configured
to perform automatic base station testing
and remote terminal, single and multimode, single and multiband equipment.
This powerful capability allows you to
create and save simple “one button” test
routines for future use. This flexibility
means you can create and execute
complex and repeatable routines no matter
what your level of expertise.
A new color VGA display gives
IFR-1900 CSA users vivid screen clarity.
Extensive use of softkeys reduces your
complex cellular / PCS parametric and
protocol tests to fast, simple and
manageable routines.
Specification
Frequency Range
10 MHz to 2010 MHz
Resolution
100 Hz
Accuracy
Same as Master Oscillator
Range
-127 dBm to + 10 dBm into 50 Ω
(T/R Connector: -30 dBm maximum with reverse
power present)
IFR-1900 CSA
Modulation
Residual AM
<0.3% RMS (50 Hz to 15 kHz BW)
(T/R) AND DUPLEX CONNECTOR
2
Duplex Connector Input Protection
Alarm sounds when level exceeds +20 dBm.
SSB Phase Noise
<-94 dBc/Hz (20 kHz Offset)
RF Signal Generator
EasySpan Software
Accuracy
± 1.5 dB (≥-110 dBm)
Resolution
0.1 dB
System Gain
28 dB ± 7dB, from GEN IF Input to T/R Ports
INTERNAL FM
Range
Off and ±100 Hz to ±100 kHz Dev.
Accuracy
± 5% (1 kHz to 20 kHz Dev, 1 kHz rate)
± 10% (1 kHz Dev and >20 kHz Dev, 1 kHz rate)
Resolution
100 Hz
Modulation Rate
1 kHz to 10 kHz - 5% accuracy
Waveforms
Sine, Square, Triangle
INTERNAL PHASE/QUADRATURE (IQ)
RF Ranges
10 MHz to 2010 MHz
IQ Error Vector Magnitude
5% from ideal DQPSK waveform
(TIA/EIA-136)
IQ Origin Offset
<-30 dBc
AF Signal Generators
AF Generators #1 and #2
Range
10 Hz to 40 kHz
Resolution
0.1 Hz ≤2 kHz
1 Hz >2 kHz
Accuracy
±0.1%
Waveshapes
Sinewave, Square, Triangle, Ramp, Pulse
Audio Frequency Counter
Frequency Range
10 Hz to 200 kHz (in 4 decade ranges)
Accuracy
Same as Master Oscillator
Resolution
0.1 Hz (10 Hz to 2 kHz)
1 Hz (>2 kHz to 20 kHz)
10 Hz (>20 kHz to 40 kHz)
Input Waveform
Sine or Square
External Level
0.5 VRMS to 30 VRMS (SINAD/BER input)
0.1 VRMS to 3.5 VRMS (EXT MOD input)
http://www.ifrinternational.com
RF Counter
PM Deviation Meter
Frequency Range
10 MHz to 2010 MHz
Deviation Range
0 Rad to 10 Rad (Peak)
Accuracy
Same as Master Oscillator
Resolution
0.01 Rad (deviation ≤5 Rad)
0.1 Rad (deviation >5 Rad)
Resolution
1 Hz (fc <20 MHz)
10 Hz (fc >20 MHz)
Carrier Range
100 MHz to 2010 MHz
Minimum Level
-60 dBm (ANT connector)
RF Frequency Error Meter
Minimum Carrier Level
-60 dBm (ANT Input Port)
AM Modulation Meter
Frequency Digital Meter Range
0 Hz to ±150 kHz
Modulation Range
1 % to 90 %
Bar Graph Meter Range
0 to ±100 kHz (in 4 decade ranges)
Resolution
1%
Accuracy
Same as Master Oscillator ± LSD
Accuracy
±5 % of full scale ±1 count + source residual AM
(30 % to 90 %)
Resolution
1 Hz (±1 Hz to ±10 kHz)
10 Hz (>±10 kHz to ±150 kHz)
Carrier Range
100 MHz to 2010 MHz
Minimum Level
-60 dBm (ANT Input Port)
RF Power Meter
Minimum Carrier Level
-60 dBm (ANT Input Port)
Distortion Meter
Frequency Range
100 MHz to 2010 MHz
Distortion Range
0.1 % to 20 %
Input Level
0.05 mW to 50 W RMS (<900 MHz, 1–2–5
sequence, 4 decade)
0.05 mW to 10 W RMS (>900 MHz, 1–2–5
sequence, 4 decade)
Resolution
0.1 %
Resolution
1%
Accuracy
±6% (>5 W and <50 W, at Typical Operational
Ambient Temperature)
LOW LEVEL POWER METER
Frequency Range
Same as standard RF power meter
Input level
-40 dBm to -10 dBm
Accuracy
±0.5 % distortion ±1 count (1 % to 10 %)
±2 % distortion ±1 count (>10 %)
Signal Frequency
700 Hz to 1.4 kHz
Signal Level
0.1 VRMS to 30 VRMS (SINAD/BER input)
Error Vector Magnitude (EVM) Meter
Input Range
NT 400 Channels
Cellular 800 MHz Channels
PCS 1900 MHz Channels
EVM Range
0 to 100 %
Receiver
Frequency Range
10 MHz to 2010 MHz
Sensitivity
<-80 for 10 dB SINAD
(1 kHz rate, 6 kHz Dev, FM 2, ANT Input Port)
Meter Residual EVM
<2 % indication
Receive IF Output Signal Frequency
88 MHz to 90 MHz
IF Bandwidth
8.5 MHz
FM Deviation Meter
Deviation Range
±100 Hz to ±100 kHz
Accuracy
± 3.0% indication, ± 1 LSD + meter residual EVM
SINAD Meter
Range
3 dB to 30 dB
Resolution
0.1 dB
Accuracy
±1 dB ±1 count (at 12 dB SINAD)
Signal Frequency
700 Hz to 1.4 kHz
Signal Level
0.1 VRMS to 30 VRMS (SINAD/BER input)
Digital Multimeter
Resolution
100 Hz (20 kHz ranges)
1 kHz (>20 kHz ranges)
VOLTMETER (DC/AC)
Accuracy
±5 % ±2 counts + source residual FM
(300 kHz IF, <15 kHz rate)
Ranges
200 mV to 200 V (full scale, decade sequence,
150 Ω, 600 Ω, 1 MΩ selectable)
Modulation Rate
100 Hz to 40 kHz
Maximum Input
1000 VDC
500 VAC
Carrier Range
100 MHz to 2010 MHz
Minimum Carrier Level
-60 dBm (ANT Input Port)
Input Impedance
1 MΩ (±5%)
150 Ω (±5%)
600 Ω (±5%)
OHMMETER
Ranges
200 Ω to 20 MΩ (full scale, decade sequence)
Resolution
3.5 digit (maximum resolution 0.1 on 200 range)
Accuracy
±5% or 0.1 (±1 count)
CURRENT METER (DC/AC)
Ranges
20 mA to 2 A (full scale, decade sequence, 20 A
maximum when using external shunt)
Resolution
3.5 digit (maximum resolution 0.01 mA on 20 mA
range)
Accuracy
±5 % or 0.1 mA ±1 count
Vertical BW
1 MHz (-3 dB)
Input Ranges
1 mV / Div to 50 V / Div (1-2-5 sequence, 8
divisions)
Max Input Vertical
200 V Peak
Accuracy Vertical
±5% of full scale
±10% of full scale (1 mV and 2 mV ranges)
Resolution Vertical
Full Scale / 256
Coupling Vertical
AC, DC, GND
Horizontal Sweep Rate
1 µSec / Div to 100 msec / Div (1-2-5 sequence,
10 divisions)
Accuracy Horizontal
±1 % of Full Scale
EVM Resolution
0.01 %
Demodulation Output Level
(FM): 5 Vp-p ±15 % (at full scale into 600 Ω)
(PM): 40 mVRMS ±15 % (5 Rad, into 600 Ω)
(AM): 1 VRMS ±15 % (80 % modulation, into
600 Ω)
(SSB): 1.15 VRMS ±15 % (Beat tone, into 600 Ω)
Frequency
DC, 50 Hz to 20 kHz
Oscilloscope
Minimum Carrier Level
-60 dBm (ANT connector)
Accuracy
12% typical
Accuracy
±5% of full scale ± 1 count (AC, where ACV*kHz
< 140)
±1% of full scale ± 1 count (DC)
Wireless - Radio test Sets
IFR-1900 CSA
Resolution
3.5 digit (maximum resolution 0.1 mV on 200 mV
range)
Resolution Horizontal
Full Scale / 400
External Input Impedance Horizontal
1 MΩ (shunted by 27 pF nominal)
Internal Signal Routing
425 kHz IF
Demod Audio
Function Generator
SINAD/BER
RF Power
EXT MOD
Spectrum Analyzer
Range
10 MHz to 2010 MHz
Frequency Span Range
1 kHz/Div to 100 MHz/Div plus Zero Scan
(10 divisions in a 1-2-5 sequence)
Accuracy
±5% of Span Width
Reference Accuracy
See Master Oscillator
Display
Log, 10 dB/Div and 2 dB/Div
Vertical Resolution
Full Scale/256
Displayed Range (Dynamic)
60 dB (0 dB Attenuation, Span <1 MHz/Div)
Bandwidth Switching Error
<2 dB (5 kHz/Div thru 1 MHz/Div)
<3 dB (<5 kHz/Div or >1 MHz/Div)
http://www.ifrinternational.com
IFR-1900 CSA
3
IFR-1900 CSA
Overall Accuracy
± 4 dB (10 MHz to 400 MHz) (normalized)
± 5 dB (>400 MHz to 2010 MHz) (normalized)
± 2 dB Log Linearity
Input Attenuator
0 dB, 20 dB, 40 dB (User selectable, ANT Input
Port)
40 dB, 60 dB, 80 dB, (User selectable Pwr <2 W,
T/R Port)
60 dB, 80 dB, l00 dB, (User selectable, Pwr >2 W,
T/R Port)
Bit Error Meter (BER)
Range
1x10-1 to 1x10-5
Data Rates
75, 150, 300, 600, 1200, 2400, 4800 bps &
16 kbps
Data Pattern Size
100 to 100,000 bits
Data Pattern Type
Random, Fixed and User Defined
Input/Output (I/O)
IEEE 488.1-1987 Internally Assigned GPIB
Addresses
System Control Processor (GPIB Address=4)
TDMA Control Processor (GPIB Address=5)
Versions & Accessories
When ordering please quote the full ordering number
information.
Ordering
Numbers
1900
1900-C
AC510
AC1009W
AC1017
AC1019
AC1020D
AC1021
AC1027
AC1036
AC1048
AC1201
AC3403
AC4103
AC8645
AC9153
Versions
IFR-1900 CSA Service Monitor
IFR-1900 CSA Service Monitor with
Certificate of Calibration
Accessories
Paging Encoder for Flex, GSC and NEC D3
EasySpan for Windows (Waveform Transfer)
AutoCell-Series II (Lucent Series II)
EasySweep (Swept Antenna Measurements)
AutoCell-NTD (Northern Telecom Cell Sites)
CellScan
AutoCell-882/884 (Ericsson)
TIA/EIA-136 Conformance Software
SSD Update & Authentication Test
Telescoping Antenna
TMAC Users Manual
Return Loss Bridge Kit(5 MHz to 2 GHz)
(Includes AC1019)
Microphone
Soft Padded Carrying Case
EasySpan, EasySweep, AutoCell and CellScan are
copyrighted by IFR Systems, Inc.
RS-232 (Asynchronous) SCSI-1 External Video
Port Operation Mode
VGA Compliant
Frequency Reference Ports
BNC Input for External 10 MHz Sync
BNC Output of Internal 10 MHz Sync
Dedicated Printer Port
25-Pin D-Sub, Centronics Compatible
IQ Output Interface
BNC Connector
TDMA Timeslot Sync
BNC Connector
Master Oscillator
Frequency Standard
10 MHz (Nominal)
Temp Stability
±0.01 ppm (0 to 50°C)
General Characteristics
Dimensions
188 mm (7.4 in) H, 478 mm (18.8 in) W, 635 mm
(25 in) D (with bail handle and front panel cover in
place)
Weight
Less than 21.8 kg (48 lb)
Operating Temperature Range
0 to 50°C
POWER REQUIREMENTS
Line
105 - 130 to 210 - 260 VAC
50 to 60 Hz @ 200 W Maximum
DISPLAY
Type
Color, Active Matrix LCD
Size
96 mm (3.8 in) wide, 86 mm (3.4 in) high
Resolution
640 pixel x 480 pixels.
IFR Americas, Inc., 10200 West York Street, Wichita, Kansas
67215-8999, USA. E-mail: info@ifrsys.com
Tel: +1 316 522 4981 Toll Free USA: 1 800 835 2352 Fax: +1 316 522 1360
IFR Ltd, Longacres House, Norton Green Road, Stevenage, Herts
SG1 2BA, United Kingdom. E-mail: info@ifrinternational.co.uk
Tel: +44 (0) 1438 742200 Freephone UK: 0800 282 388 Fax: +44 (0) 1438 727601
As we are always seeking to improve our products, the information in this document gives only a general indication of the product capacity, performance and suitability, none of which shall form part of any
contract. We reserve the right to make design changes without notice. All trademarks are acknowledged. Parent Company IFR Systems, Inc. © IFR Ltd. 1999.
4
IFR-1900 CSA
http://www.ifrinternational.com
Part no. 46891-028
Revision A
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising