Model 41 Precision Low Profile Load Cell DESCRIPTION

Model 41 Precision Low Profile Load Cell DESCRIPTION
Model 41
Precision Low Profile Load Cell
DESCRIPTION
Model 41 is a low profile “pancake” type load cells. These
reduce off-center and side-loading effects. It provides high
bonded foil, strain gage load cells are engineered to measure
performance in non-linearity, hysteresis, and repeatability speci-
loads from 5 lb to 500,000 lb. The tension/ compression
fications for such applications as tube mills, extruding processes
Model 41 is designed with the threaded hole running completely
and weighing. Each unit has a welded construction and can be
through the center of the cell. Model 41 utilizes two stabilizing
hermetically sealed for added durability. Model 41 load cells are
diaphragms, which are welded to the sensing member to
available with optional 0 Vdc to 5 Vdc or 4 mA to 20 mA output.
Approved
FEATURES
•
0.1 % accuracy
•
5 lb to 500000 lb
•
mV/V output (standard); 4 mA to 20 mA and 0 Vdc to 5 Vdc
(optional) outputs
•
Double diaphragm design
•
Intrinsically safe available (2N option only)16
• CE approved17
Approved
Model 41
PERFORMANCE SPECIFICATIONS
MECHANICAL SPECIFICATIONS
Characteristic
Measure
Characteristic
Measure
Load ranges18
5 lb to 500000 lb
Maximum allowable load
150 % FS 1
Non-linearity, 5 lb to 25 lb
±0.2 % full scale
Weight
See table
Non-linearity,
50 lb to 500000 lb
±0.1 % full scale
Material
Less than 200,000 lb
17-4PH stainless steel
Hysteresis, 5 lb to 25 lb
±0.1 % full scale
±0.08 % full scale
Material greater than or
equal to 300000 lb
Carbon steel
Hysteresis,
50 lb to 500000 lb
Deflection
See table
Non-repeatability, 5 to 25 lb
±0.1 % full scale
Natural frequency
See table
Non-repeatability,
50 lb to 500000 lb
±0.03 % full scale
RANGE CODES
Output (tolerance),
5 lb to 25 lb
2 mV/V ±0.5 % full scale
Output (tolerance),
50 lb to 500000 lb
3 mV/V ±0.5 % full scale
Operation
Compression/tension13
Resolution
Infinite
Standard calibration
5-point calibration: 0 %, 50 % and 100
% of full scale in tension only
ENVIRONMENTAL SPECIFICATIONS
Characteristic
Measure
Temperature, operating
-54 °C to 121 °C [-65 °F to 250 °F]
Temperature, compensated
15 °C to 71 °C [60 °F to 160 °F]
Temperature effect, zero
0.002 % full scale/°F
Temperature effect, span
0.002 % full scale/°F
ELECTRICAL SPECIFICATIONS
Range
Code
Available ranges Range
Code
Available ranges
AT
5 lb
DV
10000 lb
AV
10 lb
EJ
15000 lb
BL
25 lb
EL
20000 lb
BN
50 lb
EN
30000 lb
BR
100 lb
EP
50000 lb
CN
250 lb
ER
75000 lb
CR
500 lb
ET
100000 lb
CV
1000 lb
FJ
150000 lb
DL
2000 lb
FL
200000 lb
DN
3000 lb
FN
300000 lb
DP
4000 lb
FP
400000 lb
DR
5000 lb
FR
500000 lb
DT
7500 lb
WIRING CODES
Measure
Connector
Unamplified (Std.)
Strain gage type
Bonded foil
A
(+) excitation
Excitation (calibration)
10 Vdc
B
(+) excitation
Insulation resistance
5000 mOhm @ 50 Vdc
C
(-) excitation
Bridge resistance
(tolerance)
350 ohm (nominal)
D
(-) excitation
E
(-) output
Zero balance (tolerance)
±1 % full scale
F
(+) output
Shunt calibration data
Included
Electrical termination (std)
5 lb to 5000 lb
PTIH-10-6P
Electrical termination (std)
7500 lb to 500000 lb
MS3102E-14S-6P
Mating connector
5 lb to 5000 lb (not incl.)
PT06A-10-6S or equiv. (AA111)
Mating connector
7500 to 500000 lb (not incl.)
MS3106A-14S-6S (AA121)
Characteristic
2 Honeywell • Sensing and Control
DEFLECTIONS AND RINGING FREQUENCIES
Capacity (lb)
Deflection @
full scale (in)
Natural ringing
frequency (Hz)
Weight
(lb)
5 to 25
0.001
2000
0.8
50 to 1000
0.002
4600
1.5
2000 to 5000
0.002
10000
2.0
7500 to 15000
0.003
6000
8.8
20000 to 50000
0.004
8000
11.0
75000 to 100000
0.006
5500
30.9
150000 to 200000
0.010
4500
46.3
300000 to 500000
0.010
4100
130.1
Precision Low Profile Load Cell
iNTERNAL AMPLIFIERS
Current twoCurrent threewire: Option
wire: Option 2j
2k
Intrinsically
safe amp: Option 2n (2N)***
0-10 V or ±10 V
@ 45 mA
4 mA to 20 mA
4 mA to 20 mA
4 mA to 20 mA
11 Vdc to 28 Vdc
15 Vdc to 28 Vdc
22 Vdc to 32 Vdc
9 Vdc to
32 Vdc
9 Vdc to
28 Vdc
45 mA
40 mA
40 mA
65 mA
4 mA to 28 mA
4 mA to 24 mA
Freq. response
3000 Hz
3000 Hz
3000 Hz
2500 Hz
300 Hz
2000 Hz
Power supply rejection
60 db
60 db
60 db
60 db
60 db
60 db
Operating temperature
-20 °F to 185 °F
-20 °F to 185 °F
-20 °F to 185 °F
0 °F to 185 °F
0 °F to 185 °F
-20 °F to 185 °F
Reverse volt. protection
Yes
Yes
Yes
Yes
Yes
Yes
Short circuit protection
Momentary
Momentary
Momentary
Yes
Yes
Yes
Wiring code: connector
A (+) Supply
B Output common
C Supply return
D (+) Output
E Shunt Cal 1
F Shunt Cal 2
A (+) Supply
B Output common**
C Supply return**
D (+) Output
E Shunt Cal 1
F Shunt Cal 2
A (+) Supply
B Output common**
C Supply return**
D (+) Output
E Shunt Cal 1
F Shunt Cal 2
A (+) Supply
B Output common**
C Supply return**
D (+) Output
E Shunt Cal 1
F Shunt Cal 2
A (+) Supply
B No connection
C No connection
D (+) Output
E Case ground
F No connection
A (+) Supply
B No connection
C No connection
D (+) Output
E Case ground
F No connection
Wiring code: cable
R (+) Supply
Bl Output common
G Supply return
W (+) Output
B Shunt Cal 1
Br Shunt Cal 2
R (+) Supply
Bl Output com*
G Supply return*
W (+) Output
B Shunt Cal 1
Br Shunt Cal 2
R (+) Supply
Bl Output com*
G Supply return*
W (+) Output
B Shunt Cal 1
Br Shunt Cal 2
R (+) Supply
Bl Output com*
G Supply return*
W (+) Output
B Shunt Cal 1
Br Shunt Cal 2
R (+) Supply
Bl (+) Output
W Case ground
R (+) Supply
Bl (+) Output
W Case ground
Amplifier
specifications
Voltage output: Option 2b
Voltage output: Option 2c
Voltage output: Option 2t
Output signal
±5 V
0-5 V or ±5 V @
45 mA
Input power (voltage)
±15 Vdc or 26-32
Vdc
Input power (current)
* Black and green wires are internally connected.
** Pins B and C are internally connected.
*** See our Web site (http://measurementsensors.honeywell.com) for the most up-to-date information regarding intrinsically safe approvals, ref. #008-0547-00.
ALLOWABLE MAXIMUM LOADS
Capacity (lb)
Side load
(lb)
Bending
(lb-in)
Torque
(lb-ft)
5 to 25
50 %
40 %
25 %
50 to 1000
45 %
35 %
25 %
2000 to 5000
30 %
25 %
25 %
7500 to 30000
20 %
20 %
15 %
50000 to 100000
20 %
20 %
15 %
150000 to 200000
20 %
20 %
15 %
300000
20 %
20 %
10 %
400000
20 %
20 %
10 %
500000
20 %
20 %
10 %
Honeywell • Sensing and Control 3
Model 41
OPTION CODES
Many range/option combinations are available in our quick-ship and fast-track manufacture programs.
Please see http://measurementsensors.honeywell.com for updated listings.
Load ranges
5, 10, 25, 50, 100, 250, 500, 1000, 2000, 5000, 3000, 4000, 7500, 10000, 15000, 20000, 30000, 50000, 75000, 100000, 150000,
200000, 300000, 400000, 500000 lb
Temperature
compensation
1a. 60 °F to 160 °F
1b. 30 °F to 130 °F
1c. 0 °F to 185 °F
1d. -20 °F to 130 °F
1e. -20 °F to 200 °F
1f. 70 °F to 250 °F
1g. 70 °F to 325 °F14
1h. 70 °F to 400 °F14
1i. -65 °F to 250 °F14
Internal
amplifiers 10
2b. 4 wire, ±5 Vdc
2c. 0-5 Vdc output
2j. 4-20 mA (three-wire)
output
2k. 4 mA to 20 mA (twowire)20
2n (2N) 4 mA to 20 mA (wire) 2u. Unamplified, mV/V output
intrinsically safe20
2t. 0 Vdc to 10 Vdc
Internal amplifier enhancements
3a. Input/output isolation19
3d. Remote buffered shunt calibratrion8
Overload
stops
4a. Overload stops
Electrical
termination
6a. Bendix PTIH-10-6P 6-pin
(ranges to 5000 lb)
6b. MS3102E-14S-6P (ranges 7500 lb and up)9
6e. Integral cable: Teflon
Shunt calibration
8a. Precision internal resistor14
Special calibration
9a. 10 point (5 up/5 down) 20 % increments @ 68 °F
9b. 20 point (10 up/10 down) 10 % increments @ 68 °F
9c. ASTM E-74 calibration
Bridge resistance
12b. 5000 ohm (foil)
Zero and span
adjustment
14a. No access to pots
14b. Top access to pots
6f. Integral cable: PVC
6g. Integral cable: Neoprene9
6h. Integral cable: Silicone
Electrical con- 15a. Horizontal electrical exit port orientation
nector orienta- 15b. Vertical electrical exit port orientation
tion
6i. Integral underwater
cable9
6j. 1/2-14 conduit fitting with
5 ft of 4 conductor PVC
cable
6q. Molded integral cable polyurethane9
6v. Phoenix connector on end of
cable
15c. Radial electrical exit port orientation
15d. Connector on end of cable
Special calibration
30a. Compression only calibration, positive in compression
30b. Tension and compression calibration, positive in tension
30c. Compression only calibration, negative in compression
30d. Tension and compression calibration, positive in compression
Bridge type
31a. Dual bridge
Shock and
vibration
44a. Shock and vibration resistance
Interfaces
53e. Signature calibration14
53t. TEDS IEEE 1451.4 module15
4 Honeywell • Sensing and Control
1j. 0 °C to 50 °C
1k. -20 °C to 85 °C
1m. -25 °C to 110 °C
Precision Low Profile Load Cell
MOUNTING DIMENSIONS
Ranges
lb
D mm
[in]
H mm
[in]
H***
mm
[in]
F#
ØG
ØK mm
mm [in] [in]
B.C.
thru
T
A mm
[in]
A* mm
[in]
B mm
[in]
B* mm
[in]
C mm
[in]
5, 10, 25
63,5
[2.50]
20,32
[0.80]
44,45
[1.75]
6
50,8
[2.000]
4,83
[0.19]
1/4-28
UNF
20,83
[0.82]
63,5
[2.5]
19,05
[0.75]
22,86
[0.9]
31,75
[1.25]
50, 100,
250, 500,
1000
76,2
[3.00]
25,4
[1.00]
44,45
[1.75]
6
57,15
[2.250]
7,11
[0.28]
3/8-24
UNF
20,83
[0.82]
63,5
[2.5]
19,05
[0.75]
22,86
[0.9]
31,75
[1.25]
2000,
3000,
4000,
5000
88,9
[3.50]
25,4
[1.00]
44,45
[1.75]
6
66,68
[2.625]
8,64
[0.34]
1/2-20
UNF
20,83
[0.82]
63,5
[2.5]
19,05
[0.75]
22,86
[0.9]
31,75
[1.25]
7500,
10000,
15000
139,7
[5.50]
45,7
[1.80]
45,7
[1.80]
8
114,3
[4.500]
10,16
[0.40]
1-14
UNS
31,75
[1.25]
58,42
[2.3]
38,1
[1.50]
38,1
[1.5]
50,8
[2.00}
20000,
30000,
50000
152,4
[6.00]
45,7
[1.80]
45,7
[1.80]
8
123,83
[4.875]
13,46
[0.53]
1 1/2-12
UNF
31,75
[1.25]
58,42
[2.3]
38,1
[1.50]
38,1
[1.5]
50,8
[2.00}
75000,
100000
228,6
[9.00]
63,5
[2.50]
63,5
[2.50]
12
196,85
[7.750]
16,76
[0.66]
2-12 UN
31,75
[1.25]
58,42
[2.3]
38,1
[1.50]
38,1
[1.5]
50,8
[2.00}
150000,
200000
279,4
[11.00]
63,5
[2.50]
63,5
[2.50]
12
241,3
[9.500]
19,81
[0.78]
2 1/2-12
UN
31,75
[1.25]
58,42
[2.3]
38,1
[1.50]
38,1
[1.5]
50,8
[2.00}
300000,
400000,
500000
355,6
[14.00]
107,95
[4.25]
107,95
[4.25]
12
298,45
[11.750]
26,16
[1.03]
3 1/2-8
UN
31,75
[1.25]
58,42
[2.3]
38,1
[1.50]
38,1
[1.5]
**
* Length of load cell with amplified option (see option codes)
** C dimension varies on high ranges. Consult factory
*** H dimension with 2n(2N) amplifier
TYPICAL SYSTEM DIAGRAM
In-line amplifiers (used with unamplified units only)
Amplifier
Output
Universal in-line amplifiers
UV
±5 Vdc
UV-10
±10 Vdc
UBP
0 ±5 Vdc
U3W
4 mA to 20 mA (3-wire)
U2W
4 mA to 20 mA (2-wire)
DIN rail mount in-line amplifiers
DV-05
0 ±5 Vdc (3-wire)
DA-05
4 mA to 20 mA (3-wire)
DV-10
0 ±10 Vdc (3-wire)
2
Model 41
Customer supplied
Chart recorder
Alarm panel
Data acquisition
Computer
PLC
1
Mounting options
1. Pull plate
2. Load button
Mating connectors & cables
PT06A-10-6S, std.
PT06E-10-6S
MS3106A-14S-6S
Display units
SC500
SC2000
SC2001
SC3004
GM (unamplified only)
GM-A (amplified only)
NK (unamplified only)
HH (unamplified only)
Honeywell • Sensing and Control 5
Model 41
Precision Low Profile Load Cell
NOTES
1.Allowable maximum loads - maximum load to be applied without
damage.2
2.Without damage - loading to this level will not cause excessive zero
shift or performance degradation. The user must consider fatigue
life for long term use and structural integrity. All structurally critical
applications (overhead loading, etc.) should always be designed with
safety redundant load paths.
3.Interconnecting shunt cal. 1 terminal with shunt cal. 2 terminal provides 50 % (unamplified units), 75 % (4 mA to 20 mA 3-wire units) or
80 % (voltage amplified units) of full scale output for quick calibration.
Shunt calibration comes standard with internal amplifier option 2b, 2c,
2t and 2j.
4.O=Orange; Y=Yellow; B=Blue; Bl=Black; R=Red; Br=Brown;
W=White; G=Green. Color specifying cable and number or letter
specifying connector.
5.No mating connector necessary for cable option.
6.Adding any internal amplifiers on 5 lb to 25 lb ranges will increase
delivery time.
7.Option 2n (2N) on 5 to 5000 lb. ranges will typically take 12 weeks for
delivery.
8.Option 3d is not available with option 2n (2N) or 2k.
9.Not available with option 1c, 1e, 1f, 1g, 1h or 1i.
10.Consult factory.
11.Availability varies with range, consult factory.
12.Option only pertinent when option 2n (2N) selected.
13.Standard calibration for tension/compression load cells is in tension
only.
14.Not available with amplified output.
15.Consult factory for TEDS availability with amplified models.
16.Range dependent; consult factory. Termination dependent; consult
factory.
17.Internal amp and termination dependent; consult factory.
18.This unit calibrated to Imperial (non-Metric) units.
Warranty. Honeywell warrants goods of its manufacture as
being free of defective materials and faulty workmanship.
Honeywell’s standard product warranty applies unless agreed
to otherwise by Honeywell in writing; please refer to your
order acknowledgement or consult your local sales office for
specific warranty details. If warranted goods are returned to
Honeywell during the period of coverage, Honeywell will repair
or replace, at its option, without charge those items it finds
defective. The foregoing is buyer’s sole remedy and is in lieu
of all warranties, expressed or implied, including those of
merchantability and fitness for a particular purpose. In no
event shall Honeywell be liable for consequential, special, or
indirect damages.
While we provide application assistance personally, through our
literature and the Honeywell web site, it is up to the customer to
determine the suitability of the product in the application.
Specifications may change without notice. The information we
supply is believed to be accurate and reliable as of this printing.
However, we assume no responsibility for its use.
WARNING
PERSONAL INJURY
•DO NOT USE these products as safety or emergency
stop devices or in any other application where failure of
the product could result in personal injury.
Failure to comply with these instructions could result in
death or serious injury.
Find out more
Honeywell serves its customers
WARNING
through a worldwide network of
MISUSE OF DOCUMENTATION
sales offices, representatives
•The information presented in this datasheet is for
reference only. DO NOT USE this document as product
installation information.
•Complete installation, operation and maintenance
information is provided in the instructions supplied with
each product.
and distributors. For application
assistance, current specifications, pricing or name of the
nearest Authorized Distributor,
contact your local sales office.
To learn more about Honeywell’s
test and measurement products,
Failure to comply with these instructions could result in
death or serious injury.
call +1-614-850-5000, visit
http://measurementsensors.
honeywell.com, or e-mail inquiries to info.tm@honeywell.com
Sensing and Control
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422 USA
www.honeywell.com/sensing
008609-3-EN IL50 GLO June 2013
Copyright © 2013 Honeywell International Inc. All rights reserved.
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising