GAIA 5~11k (20090819)
GAIA series
Single phase 5-11 kVA
Uninterruptible Power Supply
The GAIA series delivers high power density, high
input power factor, and low current harmonics with
its advanced architecture. Designed in a rack or
tower configuration, this UPS offers unmatched
performance for servers, data centers, networking,
VOIP and telecommunications.
You can install the GAIA series 5-11 kVA in 1+1
parallel redundancy to provide even higher reliability.
With an extended battery source, it delivers the desired
runtime for your mission critical applications.
Availability
Flexibility
Lowest Total Cost Of Ownership
• Double-conversion technology.
Provides 24/7 full-time protection.
• 1+1 parallel redundancy without
requiring extra hardware.
• Input voltage bears up to 330Vac.
Suitable for severe utility conditions.
• Automatic input frequency (50 or 60Hz)
detection.
• AC-start and battery-start capabilities.
• Rack or tower configuration.
• Additional charger installs inside the UPS
to reduce recharging time.
• Multi-language LCD display.
• Optional maintenance bypass box for
parallel redundancy with manual bypass
switch.
• Optional extended battery cabinet for longer
backup time.
• High input power factor (pf > 0.99) and low
harmonic distortion (iTHD < 5%).
• Shared battery allows cost savings.
• Wide input voltage range and stable power
supply extends battery lifetime.
Industry
Server
Network
Security
Medical
Industry
$
Banking
Rack/Tower Configuration
GAIA series
Single phase 5-11 kVA
Technical Specifications
Input
Model
GA5000RL
GA7000RL
GA11000RL
Power Rating
5kVA / 3.5kW
7kVA / 4.9kW
11kVA / 8kW
Rating Voltage
V
200/208/220/230 /240, single phase
Voltage Range
Input Current Harmonic
Distortion (iTHD)
V
100 ~ 300 (full load) *
%
< 5 (full load)
Power Factor
V
Frequency
Hz
330 ± 10
Optional **
50 or 60 (range : 40 ~ 70)
Electrical Connection
Output
Terminal block
Voltage
V
Voltage Harmonic
%
≤ 2 (linear load)
Voltage Regulation
%
± 1 (static) ; ± 2 (typical)
Frequency
Hz
Overload
200/208/220/230(default)/240, single phase
50 or 60 ± 0.05
≤ 105% : Continuous ; 105~110% : 10 minutes ;
111~125% : 5 minutes ; 126~150% : 30 seconds ; >150% : Immediately
Electrical Connection
Rating Voltage
Battery
192
240
Built-in : max. 4 Amp (adjustable) ;
Optional extra charger : max. 4 Amp (internal installation)
Recharging Capability
Delta standard cable
AC input/output, Bypass, Inverter, Fault, Overload, Battery replacement,
Battery backup
Input/Output, Bypass, Inverter, Frequency, Loading and battery level,
Abnormal message and intelligent self diagnosis
LED
Display
LCD (Multi-Language)
Standard
RS232 x 1, SNMP slot x 1, Smart slot x 1, Parallel port x 1
SNMP card, Modbus card, Relay I/O control card, EnviroProbe, SNMP hub
SNMP Slot
Optional
Accessories Smart Slot
Conformance
Mini SNMP card, Mini relay I/O control card, USB card, TVSS card
Safety
CE, TUV, EN62040-1-1
EMC
1+1 Redundancy
REPO
RJ11 connector
Common Battery Installation
Feasible
Optional Accessories
Efficiency
Overall
Rail kit ; Maintenance bypass box ; Extended battery cabinet
Normal (AC-AC)
%
92 (full load)
Economic
%
96 (full load)
Temperature
ºC
0 ~ 45
Relative Humidity
%
5 ~ 95 (non-condensing)
Noise (at one meter)
Dimensions UPS
(WxDxH)
Weight
11kVA + Battery Cabinet
CISPR 22 Class A
Parallel Redundancy
Others
5 and 7kVA + Battery Cabinet
Terminal block
V
Electrical Connection
Interface
Friendly LCD Display
> 0.99
Voltage Transient Protection
Battery Cabinet
UPS
Battery Cabinet
dBA
mm
kg
55
60
440 x 670 x 89
440 x 628 x 131
440 x 610 x 89
14.5
440 x 595 x 131
15
40
20.5
66
Power Management Software
* Lower range 100~156Vac is acceptable under 50~100% loading conditions.
** External over-voltage cut-off device.
All specifications are subject to change without prior notice.
Delta offers full-scale UPS solutions from
0.6kVA to 4000kVA to fulfill all your power security needs.
090814
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising