FIGURE C - Determining the Pumping Range in cm
SPECIFICATIONS
tether length
8
15
23
30
38
46
56
pumping range
20
28
38
53
71
79
91
Cable
Flexible 18 gauge, 2 conductor, water-resistant. (standard)
Flexible 18 gauge, 3 conductor, water-resistant. (SPDT)
Use only as a guide. Pumping ranges are based on testing in nonturbulent conditions. Range may vary due to water temperature and
cable shape.
Note: As the tether length increases, so does the variance of the
pumping range.
Float
7.0 cm diameter x 12.3 cm (2.74 x 4.83 inch), high impact, corrosion
resistant, polypropylene housing for use in sewage and non-potable
water.
PULSAR
Process Measurement
user guide
Operating Temperature Range
Water up to 60 oC (140 oF).
FIGURE D - Tether arrangement
Maximum Water Depth
9 m (30 feet) or 90 kPa (13 psi)
Max. Pump Running Current
10 A @ 125 V AC 50/60 Hz Single Phase
8 A @ 250 V AC 50/60 Hz Single Phase
Max. Pump Starting Current
60 A @ 125 / 250 V AC 50/60 Hz Single Phase
Note: This switch must be used with pumps that provide integral
thermal overload protection.
The switch is not recommended for controlling:
⇒
loads less than 100 mA 12 V AC
⇒
non-arcing electric loads
This equipment is suitable for IEC 664 category II installations
©
This equipment is protected by double insulation
PREVENTATIVE MAINTENANCE
Periodically inspect the product. Check that the cable hasn’t become
worn or that the housing hasn’t been damaged so as to impair the protection of the product.
Replace the product immediately if any damage is found or suspected.
P U L S A R Process Measurement Limited
Cardinal Building
Tel:
+44 (0)1684 891371
Enigma Commercial Centre Fax:
+44 (0)1684 575985
Sandy’s Road
Malvern WR14 1JJ
email
info@pulsar-pm.com
United Kingdom
web http:\\www.pulsar-pm.com
©PULSAR Process Measurement Limited 2010 Version 4.0 June 2010
M-800-0050-D
Micro Master
P U L S A R p o i n t 800-50 Micro Master Pump Switch
Mechanically-activated, wide-angle switch designed for performance and reliability.
INSTALLATION
FIGURE A - Wiring Diagrams
Determine the pumping range for the installation (see Figures B and
C).
Do not tether less than 8 cm (3 inches) from the pipe.
APPLICATIONS
The Micro Master pump switch provides automatic control of pumps in
sump, sewage and non-potable water applications.
The Micro Master pump switch is not sensitive to rotation and can be
used in either calm or turbulent applications.
The SPDT version can be wired to work in either pump up (Normally
Closed) or pump down (Normally Open) applications.
Tighten the strap around the discharge pipe keeping the switch cable between the strap and the pipe to prevent slippage.
Space small ties at least 2.5 cm (1 inch) apart (see Figure D).
To re-adjust ties, press small tie tabs down.
To lock the releasable tab, run the remaining strap between the tab
and the head. Pull tightly
To eliminate any obstructions to the switch, tuck the strap back
through the head (see Figure D).
Wire switch as shown in Figure A.
Check installation.
Allow system to cycle to ensure proper operation.
FIGURE B - Installation of MicroMaster Pump Switch
OPTIONS
! WARNING !
⇒ 3 m or 10 m cable
⇒ Pump up, Pump down or SPDT versions
⇒ with an adjustable mounting strap or with a cable weight.
FEATURES
⇒ ELECTRICAL SHOCK HAZARD Disconnect power
before installing or servicing this product.
⇒ Mechanically activated, snap action contacts.
⇒ Do not use this product as a mains isolating switch.
⇒ High impact, corrosion resistant, polypropylene float housing.
⇒ This product is not approved for use in Hazardous
Areas
⇒ Adjustable pumping range of 20 to 91 cm (8 to 36 inches)
⇒ Includes standard mounting strap or cable weight
⇒ The SPDT version can be wired as pump up (NC) or pump down
(NO)
⇒ For use in non-potable water and sewage applications
⇒ Two-year warranty.
⇒ CE Approved.
⇒ Failure to follow these precautions could result in
serious injury or death.
⇒ Keep these instructions in a safe place after installation.
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising