CompuPack

CompuPack
CompuPack
Compulite Systems (2000) Ltd.
9 Hanagar St. Neve Ne'eman B Industrial zone Hod Hasharon, 45421, Israel
Tel: 972 9 744 6555 ~ Fax: 972 9 746 6515 ~ www.Compulite.com
Copyright © 2007 Compulite Systems (2000) Ltd. All rights reserved.
This guide is delivered subject to the following conditions and restrictions:
This product or document is protected by copyright and distributed under licenses
restricting its use, copying, distribution and decompilation. No part of this product or
document may be reproduced in any form by any means without the prior express written
authorization of Compulite Systems (2000) Ltd. and its licensors (if any). Information
contained herein is subject to change without notice.
Document version 2.0
March 2007
Table of Contents
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Connecting CompuPack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
User interface and controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
CompuPack programmer operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Patch menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Test menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Curve menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Setting curves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Setup menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Programming menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Scenes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Sequences . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Playing back scenes and sequences . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Run menu activation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
DMX trigger . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Diagnostics menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Upgrading CompuPack software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Upgrading via RS-232 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Overview
CompuPack offers a simple and affordable 19”, 3 U digital dimming
system, for fixed or mobile applications. CompuPack can operate as a
stand alone unit or with any lighting control system.
Features
Hardware
„ 12 x 2.5KW dimmers
„
19'' x 3U
„
Graphic (128x64) LCD display
„
Seven Input buttons
„
Twelve Tri-color status LEDs
„
Control input: 2 DMX, Ethernet, Analog 0-10V, RS-232
„
Status feedback to Compulite consoles via Ethernet (option)
„
Software upgrade through RS232 (Ethernet optional)
„
Software (DSP) regulated output specially designed for operating in
unstable power input conditions.
Hardware options
„ Dual-SCR or Triac
„
1 or 2 DMX inputs, Ethernet support, Analog (0-10V) support
„
Outputs: Socapex, Harteng, Schuko terminals
Software
„ Patch - DMX input port and offset settings for each individual
dimmer.
„
Test menu
„
Fifty programmable scenes triggered via RS232, RS485, analog or
Ethernet
„
Nine programmable sequences (loops) triggered via RS232, RS485,
analog or Ethernet
„
Built in sequencer for stand alone operation
„
Six pre-programmed dimmer curves
„
Four programmable dimmer curves
1
COMPULITE
Connecting CompuPack
End equipment is connected via:
„
Socapex connectors
„
Harting connectors
„
Schuko connectors
Input can be:
„
Direct DMX from a lighting console
„
DMX over Ethernet (VCs) when teamed with Compulite consoles
„
Analog 0-10 V - not implemented yet.
„
RS-232- not implemented yet.
To connect CompuPack
1 Plug the 3- phase connector into its socket on CompuPack.
2 Connect to the mains supply.
3 Connect the end equipment to CompuPack.
4 Connect the DMX IN or Ethernet communication cables.
5 Switch on the power.
The LEDs for L1, L2, and L3 indicate 3-phase status.
User interface and controls
CompuPack has a graphic 128 x 64 LCD for menu and value displays. There
are user buttons for navigating and entering values.
Figure 1: LCD main screen and buttons for navigation and programming
2
CompuPack
CompuPack programmer operation
CompuPack programmer operation
The CompuPack programmer is menu driven software. CompuPack software
has seven menus:
:
„
Patch
„
Prog(ramming)
„
Test
„
Run
„
Curves
„
„
Setup
„
Diag(nostics)
Page (available when the 24 dimmers
option is enabled)
:
Navigating and selecting menus
Menu
State
Arrows
Enter key
Esc key
Idle
Navigate states
Select state
N/A
Selected state
Navigate substates
Select sub-state
Return to idle
Selected substate
Navigate items
Select item
Return to
selected state
Selected item
Edit value
Store value
Discard change
Patch menu
You can change default DMX value in the Patch menu.
The default is one-to-one patch, offset from dimmer number 1. DMX values
that are displayed in parentheses - () - are the default assignments.
Figure 2: CompuPack dimmers with default DMX values
DMX values that displayed without parentheses indicate that the dimmer’s
DMX values has been changed.
3
COMPULITE
Figure 3: Dimmer 6 has a new DMX value
You can set the dimmers in CompuPack to listen to DMX In 1, DMX In 2, or
VCs over Ethernet.
To change a DMX value
1 Use the arrows to navigate to the Patch menu and press ENTER.
The Patch menu opens.
2 Use the arrows to select a dimmer and press ENTER.
3 Use Sor T to set a value for units and press ENTER to store.
4 Press W to access the tens and then use Sor T to set a value.
5 Press W to access the hundreds and then use Sor T to set a value.
6 Press ENTER to store.
To change the input source
If the input source is currently DMX In 1, set the DMX value to 513. The
input source switches to D2 001.
To set Ethernet as the input, set D2 to 513. The input source switches to E
001.
To reset one dimmer to the default patch
1 Navigate to the dimmer and press ENTER.
2 Press W to access the hundreds and then use Sor Tthat cycles the
input source (D1, D2, E).
When reaching the default source the DMX value jumps to its correct
default value.
3 Press ENTER to store.
To reset the patch
See “Reset Patch” on page 8.
4
CompuPack
CompuPack programmer operation
Test menu
The Test menu allows you to test dimmers sequentially starting from a selected
dimmer or test a range of dimmers. When testing is active, the selected
dimmers fades repeatedly from zero to full.
To test dimmers
1 Use the arrows to navigate to the Test menu and press ENTER.
The Test menu opens.
2 Use the arrows to highlight the first dimmer.
The first dimmer repeatedly fades from zr to FL.
3 Use X andW to move from dimmer to dimmer.
4 Press ENTER or ESC to stop the test.
To test a range of dimmers
Example: Test dimmers 6 through 10 together.
1 Use the arrows to navigate to the Test menu and press ENTER.
The Test menu opens.
2 Press X to select Dimmer Range.
3 Navigate to dimmer 6, the first dimmer in the range as per this
example, and press ENTER.
Dimmer 6 appears on a dark field.
4 Press X to select dimmer 7.
Dimmer 7 appears on a dark field.
5 Continue pressing X until all required dimmers are selected.
6 Press ENTER.
The selected range of dimmers repeatedly fade from zr to FL.
7 Press ESC to stop the test.
Note: To pause a test, press ENTER.
Curve menu
In the curve menu you can:
„
Set curves for selected dimmers
„
Program custom curves for selected dimmers
5
COMPULITE
There are 6 pre-programmed curves and 4 programmable custom curves
available.
Figure 4: Dimmers displayed with their curves
Setting curves
CompuPack has six pre-programmed curves.
Icon
Curve
Linear
Inverted
Non-Dim - when reaching 50%, jump to FL
Preheat - maintain lamp at 5%
S
Park - at 100%
To set a curve for selected dimmers
1 Use the arrows to navigate to the Curve menu and press ENTER.
The Curve menu opens to the Select Curve sub-menu.
2 Use the arrows to select a dimmer and press ENTER.
3 Use T or S to select the required curve.
4 Press ENTER to store the curve to the selected dimmer.
To program a custom curve
1 Use the arrows to navigate to the Curve menu.
2 Press ENTER to select the menu.
6
CompuPack
CompuPack programmer operation
3 Navigate to the Program Curve sub-menu.
4 Navigate to Curve Number and press ENTER.
5 Use T or S to select the curve number and press ENTER.
Four programmable curves are available.
Figure 5: Program curve sub-menu
6 Navigate to Edit Steps and press ENTER.
The curve steps are displayed.
Figure 6: Each programmable curve has ten steps.
7 Use W or X to select a step.
8 Use T or S to set the step’s level.
9 Repeat 7 and 8 for each curve step.
10 Press ENTER.
11 Navigate to Save Changes and press ENTER.
12 Press ESC to return to the main screen.
7
COMPULITE
Setup menu
Setup
submenus
Submenu options
General
Merge Inputs
Yes - Not implemented yet.
No- Dimmers receive input only from the
source set in the Patch menu.
Input regulation
All settings
(180v, 190v, 200v, 210v, 220v) - Keep the
output reliable at the selected voltage.
None - the input is not regulated
Note: Unsteady input may result, for instance,
from power supplied by a generator.
24 dimmers
Not implemented yet
DMX trigger
Yes - Trigger scenes or sequences via
DMX.
No - DMX trigger is disabled.
Note: Pressing ENTER cycles through the
options: None, Scenes, Seqs.
Reset Patch
Yes - Reset the patch to D1and start from
DMX value 001.
No - This is the default setting.
Clear All Data
Delete all scenes and sequences.
On Loss of DMX Hold DMX
values
Yes - Retain last received values.
No - Dimmers fade to zero.
Power up
options
Fade to
Scene
Fade to the selected scene.
Wait time
Wait time before fading to a scene or to
zero.
Run Scene
When a scene or sequence is selected,
CompuPack automatically runs it when
powered up.
Run
Sequence
Network
IP
Subnet
Input VC
8
Set IP address and Subnet mask to receive
input via Ethernet.
VC (Virtual Connector) is Compulite’s
protocol for DMX over Ethernet.
CompuPack
CompuPack programmer operation
To set general options
1 Use the arrows to navigate to the Setup menu and press ENTER.
The Setup menu opens.
2 Use Tor S select the option.
3 Press ENTER to toggle Yes (enabled) or NO (disabled).
To set behavior when losing DMX input
1 Use the arrows to navigate to the Setup menu and press ENTER.
The Setup menu opens.
2 Navigate to On Loss of DMX and press ENTER.
Figure 7: Loss of DMX options
3 For Hold DMX Values - press ENTER to toggle Yes (enabled) or NO
(disabled).
For Fade to Scene - use the arrows to select the scene number and
press ENTER.
For Wait - use the arrows to set the wait time and press ENTER.
Note: When DMX input is restored, the active scene must be
cleared before CompuPack can resume normal operation. See
“stop active scenes and sequences” on page 13.
To set power up behavior
1 Use the arrows to navigate to the Setup menu and press ENTER.
The Setup menu opens.
2 Navigate to Power Up Options and press ENTER.
9
COMPULITE
Figure 8: Run lighting states on power up options
3 Navigate to Run Scene and press ENTER. Then use the arrows to set
the scene number and press ENTER.
Or
Navigate to Run Sequence and press ENTER. Then use the arrows to
set the sequence number and press ENTER.
When CompuPack powers up, the selected scene or sequence automatically begins running.
To set network parameters
1 Use the arrows to navigate to the Setup menu and press ENTER.
The Setup menu opens.
2 Navigate to Network and press ENTER.
Figure 9: Network setup
3 For IP - use the arrows to set the IP address and press ENTER.
For Sub - use the arrows to set the subnet and press ENTER.
For Input VC - use the arrows to set the VC that CompuPack is
listening to and press ENTER.
10
CompuPack
CompuPack programmer operation
Programming menu
Through the Programming menu, program scenes and sequences that can be
played back by CompuPack. When programming scenes, external values
(DMX or Ethernet) are merged (HTP) with CompuPack programmer values.
Scenes and sequences are activated through the Run menu or can be triggered
via DMX transmission. See “Playing back scenes and sequences” on page 13.
Scenes
You can store up to 50 scenes. Scene properties include:
„
Dimmer levels and timing data
„
Fade up, down, and wait times
„
Time range is 00:00.1 (0.1 sec.) – 30.00.0 (30 minutes)
To program scenes
1 Use the arrows to navigate to the Prog(ramming) menu and press
ENTER.
The Scene Levels screen is displayed.
2 Use the arrows to select a dimmer and press ENTER.
3 Use Tor Sto set a the dimmer level and press ENTER to store.
Figure 10: Setting dimmer levels in the Programming menu
4 Repeat steps 3 and 4 until the entire scene is programmed.
5 Press ESC to return the main Prog menu.
6 Select Scene Properties and press ENTER.
7 Use Tto select Number.
8 Use Tor Sto set the scene number and press ENTER.
9 Set scene fade times.
10 Navigate to the Save Changes option and press ENTER to store the
scene properties.
11
COMPULITE
To set scene properties
1 On the main Prog menu screen, navigate to Scene Properties and press
ENTER.
2 Use Tor S to select an option and press ENTER.
3 Use the arrows to set values and press ENTER to store.
Figure 11: Setting scene properties
4 Navigate to the Save Changes option and press ENTER to store the
scene properties.
Sequences
Sequences are a collection of scenes that run in loops.
You can store up to 9 sequences.
Sequence properties include:
„
Start scene, end scene, and number of loops
„
Number of loops: 1-999 or infinite
„
Nested loops - not implemented yet
To program sequences
1 On the main Prog menu screen, navigate to Sequence and press
ENTER.
2 Navigate to Number and use the arrows to set the sequence number.
Figure 12: Setting sequence properties
3 Navigate to Start Scene and use the arrows to select the first scene in
the sequence.
12
CompuPack
CompuPack programmer operation
4 Navigate to End Scene and use the arrows to select the last scene in the
sequence.
5 Navigate to Loops and use the arrows to enter the number of times the
sequence will repeat.
6 Navigate to the Save Changes option and press ENTER to store the
scene properties.
Playing back scenes and sequences
Scenes and sequences can be activated in two ways:
„
Through the RUN menu
„
Through DMX triggering
Run menu activation
The Run menu plays back pre-programmed scenes and sequences. Scenes and
sequences are programmed in the Programming menu. See “Programming
menu” on page 11.
To run scenes and sequences via the Run menu
1 Use the arrows to navigate to the Run menu and press ENTER.
The Run menu opens.
2 Use Tor S to select Scene or Sequence and press ENTER.
Seq #
(Loops)
Current/Next scene
Fade times
Progress bars
Figure 13: The Run screen with sequence details
3 Use the arrows to set the scene or sequence number and press ENTER.
The scene or sequence begins its fade.
To stop active scenes and sequences
1 Use the arrows to navigate to the Run menu and press ENTER.
2 Navigate to Clear and press ENTER.
Or
13
COMPULITE
Press ENTER twice at any point in the Run menu.
ATTENTION! If CompuPack was set to run a scene after losing the
DMX signal, you must clear the scene when DMX reception is
restored.
DMX trigger
Either scenes or sequences can activated through a DMX trigger. DMX
channel 1 triggers scene 1, DMX channel 2 triggers scene 2, and so on, up to 50
scenes. When a scene or sequence is active, external input (from DMX or
Ethernet) are ignored.
When DMX triggering is enabled:
„
A scene or sequence is activated if the input value for the matching
dimmer rises to more than 5%.
„
The scene or sequence stops when the input value falls below 5%.
To run scenes or sequences via DMX triggers
Enable DMX trigger seq in the Setup menu ` General tab.
Diagnostics menu
Check the status of:
14
„
Phase 1 - voltage input
„
Phase 2 - voltage input
„
Phase 3 - voltage input
„
Rack temperature
„
Software version
CompuPack
Upgrading CompuPack software
Upgrading CompuPack software
Upgrading CompuPack software is done directly through the serial RS-232
port.
Upgrading via RS-232
Requirements:
„
Serial RS-232 cable
„
SDFlash Serial RS232 utility (version 1.63.00 or higher) - included in
CompuPack installation disk
„
Laptop or PC with serial RS-232 port
„
Laptop or PC with SDFlash Serial installed
„
New project set up in SDFlash Serial
To prepare the hardware
1 Turn off CompuPack.
2 Remove the top cover.
3 Identify the jumper labeled J1.
4 Move the J1 jumper from pins 2 and 3 to pins 1 and 2.
5 Connect CompuPack to the laptop or PC via the RS-232 serial port.
6 Power up CompuPack.
The screen is blank.
7 Open the SDFlash utility on the laptop or PC.
8 Follow the SDFlash instructions for flash programming.
9 When the update is complete, turn off CompuPack.
10 Move J1 back to pins 2 and 3.
11 Replace the top cover.
12 Power up CompuPack.