Catalog: Solenoid Driven Pumps Catalog Section

Catalog: Solenoid Driven Pumps Catalog Section
Solenoid-driven Metering Pumps
Ta b l e o f C o n t e n t s
“Solenoid-Driven Metering Pumps” T.O.C.
III
CATALOG SECTION TABS
 pump selection by capacity
 chemical resistance list
 Solenoid & Motor Pump Overview
extronic
motor-driven
metering pumps
 Sigma/ 1
Orlita
 Sigma/ 2
DulcoFlex
pump spare parts &
accessories
 mikro delta
beta
pump spare parts
& accessories
analytical
instrumentation
solenoid-driven
metering pumps
 concept PLUS
DULCOMETER
instrumentation
analytical
sensors
solenoid-driven
metering pumps
 Analytical Instrumentation Overview
motor-driven
metering pumps
product
overview
product
overview
 Introduction
DULCOTEST
sensors
®
®
polymer blending &
dry feed solutions
28
 gamma/ X
gamma/L
delta
 Sigma/ 3
ProMus
Makro
 solenoid pump spare parts
 motor pump spare parts
 pump accessories
D1C
MicroFlex
D2C
SlimFlex
Dulcometer® Compact
MultiFLEX
DMT
AEGIS
DDC
 amperometric sensors
 potentiometric sensors
 potentiostatic sensors
 conductometric sensors
 accessories
 ProMixTM -M (In-line Controls)
 ProMixTM -M (Batch & In-line Controls)
 ProMixTM -S
 ProMixTM -C
 ProMdryTM
01/06/2016 - Solenoid-Driven Metering Pumps
P r o M i n e n t ® C o n c e p t PLUS
Solenoid Diaphragm Metering Pumps
Overview: Concept
PLUS
Ideal for basic chemical feed applications
(see page 132 for spare parts)
 Capacity range of 0.20 to 3.94 GPH (0.74 to 14.9 LPH) at pressures up to 232 psi (16 bar).
 Continuous stroke length adjustment from 0-100 % (recommended 30-100 %)
 Fixed frequency settings @ 0, 25, 50, 75 and 100%.
 Low cost opens up opportunities in the most basic applications
product
overview
 NP, PP and PVT liquid ends
 Integral bleed valve simplifies priming and prevents “loss of prime” prevents “loss of prime”
 Common applications: Cooling towers, chlorination and metal finishing
analytical
instrumentation
pump spare parts &
accessories
motor-driven
metering pumps
solenoid-driven
metering pumps
 Certified to NSF/ANSI 61
analytical
sensors
pk_1_005
30
01/06/2016 - Concept PLUS
P r o M i n e n t ® C o n c e p t PLUS
Solenoid Diaphragm Metering Pumps
Capacity Data
1000
1601
1002
1003
0704
0705
0308
0215
145
232
145
145
101
101
43
21
(10)
(16)
(10)
(10)
(7)
(7)
(3)
(2)
0.20 (0.9)
0.26 (1.0)
0.53 (2.0)
0.70 (2.7)
1.00 (3.7)
1.40 (5.2)
2.25 (9.0)
3.94 (14.1)
mL/
stroke
Max.
Stroking
Rate
spm
0.07
0.10
0.18
0.19
0.36
0.38
0.79
1.40
180
240
180
240
180
240
180
180
Pre-Primed
Suction
Lift
ft. (m)
20
20
16
16
13
13
20
5
(6)
(6)
(5)
(5)
(4)
(4)
(6)
(1.5)
Tubing
Connectors
O.D. x I.D. (in.)
1/4” x 3/16”
1/4” x 3/16”
1/4” x 3/16”
1/4” x 3/16”
1/4” x 3/16”
1/4” x 3/16”
3/8” x 1/4”
3/8” x 1/4”
Shipping
Weight
(approx.)
lbs.
(kg)
3.97
3.97
3.97
3.97
3.97
3.97
3.97
3.97
(1.8)
(1.8)
(1.8)
(1.8)
(1.8)
(1.8)
(1.8)
(1.8)
solenoid-driven
metering pumps
(Note: Above capacities and suction lift refer to pumps tested on water at 115 VAC, 60 Hz, and an ambient
temperature of 70*F (20*C). Higher specific gravity fluids will reduce suction lift. Capacities will be slightly
reduced from published ratings if pumps are skid mounted)
External pulse contact retrofit available as an option (P/N 1022000)
Materials In Contact With Chemicals
Pump head
Polypropylene
Polypropylene
Acrylic Acrylic Valves
Polypropylene
Polypropylene
PVC
PVC
O-rings
EPDM
Viton® EPDM
Viton® Balls
ceramic
ceramic
ceramic
ceramic
PVT
PVDF PVDF
PTFE
ceramic
motor-driven
metering pumps
PPE
PPB
NPE
NPB
product
overview
Pump
Version
Capacity at Maximum
Back Pressure
U.S.
psig (bar) GPH (L/h)
pump spare parts &
accessories
Pump diaphram with PTFE-coating.
Note: Viton® is a registered trademark of DuPont Dow Elastomers.
analytical
instrumentation
analytical
sensors
01/06/2016 - Concept PLUS
31
P r o M i n e n t ® C o n c e p t PLUS
Solenoid Diaphragm Metering Pumps
Identcode Ordering System
CNPa
Concept PLUS
Version: Capacity:
1000
1601
1002
1003
0215
1.03 gph ( 3.9 l/h), 102 psi (7 bar)
2.10 gph ( 8.0 l/h), 43.5 psi (3 bar)
3.17 gph (13.5 l/h), 29 psi (1.5 bar)
Liquid end material:
PV
product
overview
0704
0308
0.53 gph ( 2.0 l/h), 145 psi (10 bar)
0.70 gph ( 2.7 l/h), 145 psi ( 10 bar)
PP
NP
Polypropylene
Acryllic/PVC
PVDF
O-rings:
B
E
T
Viton/b
EPDM
PTFE
Liquid end version:
0
Without bleed valve, without valve springs
solenoid-driven
metering pumps
1
2
3
Without bleed valve, with valve springs
With bleed valve, w/o valve springs (except 0704 models)
With bleed valve, w/o valve springs
Connection:
motor-driven
metering pumps
0
B
Standard (in accordance with technical data)
Special connection 3/8" x 1/4"
Labeling:
0
Standard with logo
Electrical connection:
A
D
U
1 ph 230 V 50/60 Hz (Euro plug)
1 ph 115 V 50/60 Hz (US plug)
1 ph 230 V 50/60 Hz (US plug) (consult factory for pricing)
Control Option:
0
Standard (w/o external control)
B
CNPa
1000
PP
B
2
0
0
A
B
Pulse control
Accessories:
1
With accessories (foot valve, injection valve, tubing)
Approval:
04
CSA
1
04
analytical
sensors
analytical
instrumentation
pump spare parts &
accessories
Version: Capacity:
0.16 gph (0.6 l/h), 145 psi (10 bar)
0.26 gph (1.0 l/h), 232 psi (16 bar)
32
01/06/2016 - Concept PLUS
P r o M i n e n t ® C o n c e p t PLUS
Solenoid Diaphragm Metering Pumps
Dimensional Drawings
Dimensions in inches (mm).
Ranges given, actual dimension dependant on liquid end material.
3.35 (85)
motor-driven
metering pumps
.72 (18.3)
5.22 (132.5)
3.33 (84.7)
solenoid-driven
metering pumps
6.25 (158.7)
product
overview
3.15 (80)
3.64 (92.5)
.24(6)
5.51 (140)
pump spare parts &
accessories
3.90 (98)
M20 x1,5
analytical
instrumentation
1.33 (33.9)
analytical
sensors
.41 (10.5)
2.21 (56.1)
4.15 (105.3)
3.0 (76)
3.90 (98)
01/06/2016 - Concept PLUS
33
ProMinent® Beta® b
Solenoid Diaphragm Metering Pumps
Overview: Beta® b
Ideal for basic chemical feed applications
(see page 135 for spare parts and page 145 for control cables)
 Capacity range 8.4 gph (32 l/h) max, 363 psi (25 bar) max
 External contact input for pulse control with a range of 1:64-64:1
 Continuous stroke length adjustment from 0-100% (recommended 30-100%)
 Supplied in PP, Acrylic/PVC, PTFE, PVDF, SS
 Patented coarse/fine deaeration for PP, and Acrylic/PVC
product
overview
 Auto-degassing liquid end in Acrylic/PVC
 HV liquid end for highly viscous media (suitable for viscosities to 3000 cPs)
 10-setting stroke frequency adjustment from 10-100%
 External control via voltage-free contacts
pk_1_004_1
 Connector for two-stage level switch
DULCOTEST®
sensors
DULCOMETER®
instrumentation
pump spare parts &
accessories
motor-driven
metering pumps
solenoid-driven
metering pumps
 12-24 V DC, 24 V AC low voltage version
 LED’s for operation status
 NSF/ANSI 61 approved
 External control via standard 4-20 mA signal
ProMinent® solenoid-driven metering pumps consist of two main components: the pump drive unit and the liquid end. The Beta series offers two drive (solenoid) sizes: Beta/4 (BT4b) and Beta/5 (BT5b). Operating principles and options are
identical, and both units offer maximum backpressure up to 363 psig (17.5 bar). Capacity range for the Beta/4 is 0.19 to
5 gph (0.74 to 19 l/h); Beta/5 is 0.80 to 8.4 gph (2.9 to 32 l/h).
Feed rate is determined by stroke length and stroking rate: stroke length can be varied from 0 to 100% with an
adjustment ratio of 10:1. The stroke length is set manually by the adjustment knob on the front of the pump.
Stroke rate can be adjusted in 10% increments between 10 and 100% via the multifunction switch. This switch is also
used to select voltage-free On/Off external pulse contact, pump stop, or test (for priming).
Specifications
Drive Unit
The pump housing is constructed of fiberglass-reinforced PPE plastic to protect against corrosion, dust, and water.
The solenoid drive unit houses a short-stroke solenoid with a maximum stroke length of 0.05” (1.25 mm). It is equipped
with a noise suppressing mechanism for quiet operation and the armature is the only moving part.
Operating on pulse action, each pulse generates a magnetic field in the solenoid coil. This magnetic field moves the
armature, which in turn moves the diaphragm. The diaphragm pushes into the dosing head and cavity forces chemical
out of the discharge valve. When the magnetic field is de-energized, a spring returns the armature and diaphragm to their
original position. This return movement draws chemical into the dosing head cavity through the suction valve.
In the event of a diaphragm rupture, the liquid end has a weep hole on the bottom of the backplate to direct chemical
out of the pump and away from the solenoid. An optional diaphragm failure detector can be used to stop the pump and
indicate a fault.
The stroke-length adjusting mechanism is connected directly to the solenoid. Adjustment results in an accurate
self-locking stroke-length setting.
polymer blending &
dry feed solutions
Diaphragm
The diaphragm is constructed of fabric-reinforced EPDM elastomer with a plastic core and PTFE-facing. It is chemically
resistant to virtually all process fluids and can be used over a wide temperature range. The Beta pump is designed with
a convex diaphragm. The curved shape provides precise metering and alleviates stress placed on the diaphragm by
reducing liquid end dead volume.
34
01/06/2016 - Beta®
ProMinent® Beta® b
Solenoid Diaphragm Metering Pumps
Specifications (Cont.)
The Liquid End
The Beta metering pump liquid ends are available in five material versions: Polypropylene (PP), Kynar
(PVDF), Acrylic/PVC (NP), PTFE (TT), and 316 Stainless steel (SS).
Some liquid ends are interchangeable between the BT4a and BT5a.
Options include a manual bleed valve with needle valve for easy priming, and continuous bleed of fluids that
tend to off-gas (available with versions PP, PVT, and NP liquid ends).
product
overview
Automatic degassing liquid ends are available for PP and NP versions (except 1000 and 0232). This style
liquid end discharges from the center and degasses from the top to prevent air build-up in the chamber.
Suction and discharge ports are equipped with double-ball check valves for superior repeatability.
Discharge
AutoDegassing
Discharge
motor-driven
metering pumps
Bleed
Valve
Discharge
Suction
Suction
Liquid end with bleed
valve
Auto-degassing
liquid end
Power Supply
The Beta metering pumps accept a universal 100-230 volt power supply (+/- 10%), single phase, 50/60 Hz, with a 1.15
service factor. Performance is identical whether operated on 50 Hz or 60 Hz power. The power cord is detachable.
DULCOMETER®
instrumentation
Fault Indicators
Three LED lights indicate operational status. A green light flashes during normal operation; a yellow light warns of low
chemical; and a red light indicates lack of chemical or an operational error.
Relay Outputs
Pulse Control Switch
Stroke Length Adjustment Knob
Fault Indicator (red)
Warning Indicator (yellow)
Operating Indicator (green)
Multifunctional Switch
"External Control" Terminal
Relay Connection (optional)
"Level Switch" Terminal
1
2
3
4
5
6
7
polymer blending &
dry feed solutions
1
2
3
4
5
6
7
8
9
DULCOTEST®
sensors
Fault annunciating relay
For low tank level (level switch), processor fault, and fuse/
power supply failure.
Pacing relay
A contact closure is issued with every pump stroke (contact
duration 150 ms). This allows a second ProMinent metering
pump to be paced synchronously, or to totalize flow with an
external stroke counter.
8
9
Recognized
Available
01/06/2016 - Beta®
pump spare parts &
accessories
Liquid end without
bleed valve
Suction
solenoid-driven
metering pumps
High viscosity PVDF liquid ends are available for pump versions 1005, 0708, 0413, 0220, 1008, 0713, and
0420. Their metering capacity is 10-20% less than standard pump versions and recommended viscosity is
up to 3000 cPs. The HV liquid ends are not self-priming; flooded suction is recommended.
P_BE_0011_SW
35
ProMinent® Beta® b
Solenoid Diaphragm Metering Pumps
polymer blending &
dry feed solutions
DULCOTEST®
sensors
DULCOMETER®
instrumentation
pump spare parts &
accessories
motor-driven
metering pumps
solenoid-driven
metering pumps
product
overview
Specifications (Cont.)
Maximum stroke length:
Materials of construction
Housing:
Diaphragm:
Liquid end options:
Enclosure rating:
Motor insulation class:
Power supply:
100-230 VAC, 1 phase, 50/60 Hz, +/- 10%; 12-24 VDC or 24VDC (+/- 10%)
Check valves:
Double ball
Metering repeatability:
0.05” (1.25 mm) Fiberglass reinforced PPE
PTFE-faced EPDM with plastic core
Polypropylene, PVDF, Acrylic/PVC, PTFE, 316 SS
IP 65
F
When used according to operating instructions, ±2% under constant conditions
and at minimum 30% stroke length
Power cord:
6 ft (2 m)
Relay cable (optional):
6 ft (2 m)
Relay load
Fault relay only (options 1 & 3):
Fault and pacing relay (options 4 & 5):
Contact load: 250 VAC, 2 A, 50/60 Hz
Operating life: > 200,000 switch functions
Contact load: 250 VAC/DC, 2 A, 50/60 Hz
Operating life: > 200,000 switch functions
Residual impedance in ON-position (RDSOn): < 8 Ω
Residual current in OFF-position: <1µA
Maximum current: < 100 mA
Maximum voltage: 24 VDC
Switch functions: 15x109
Contact closure: 100 µs (for pacing relay)
Ambient temperature range:
Max. fluid operating temperatures:
Material
Acrylic/PVC
Polypropylene
PTFE
316 SS
PVDF
Average power drain at maximum
stroking rate (Watts) / current
drain at pump stroke (Amps)
BT4a:
BT5a:
17W / 0.7 A or 15 A (peak current for approx. 1 µs)
22W / 1.0 A or 15 A (peak current for approx. 1 µs)
Service factor:
Warranty:
Industry standards:
Valve threads:
Standard Production Test:
Max. solids size in fluid:
Controlling contact (pulse):
Necessary contact duration:
Recommended Viscocity:
36
14°F (-10°C) to 113°F (45°C)
Constant
113°F (45°C)
122°F (50°C)
122°F (50°C)
122°F (50°C)
149°F (65°C)
Short Term
140°F (60°C)
212°F (100°C)
248°F (120°C)
248°F (120°C)
212°F (100°C)
1.15
2 years on drive, 1 year on liquid end (extended warranties available)
UL recognized, CE available for U.S.A. and Canada, NSF/ANSI 61
Metric thread for PP, NP, PVT, and TT versions. 1/2” MNPT connections are
available in all materials.
All pumps are tested for capacity at maximum pressure prior to shipment.
Pumps with 1/4” valves: 15µ - Pumps with 1/2” valves: 50µ
With voltage free contact, or with semiconductor sink logic control (NPN), not
source logic (PNP). With a residual voltage of <700 mV, the contact load is
approximately 0.5 mA at +5 VDC. (Note: Semiconductor contacts that require
>700 mV across a closed contact should not be used.) Pump ignores contacts
exceeding maximum input rate.
20 µs
max. 200 cPs for standard liquid end
max. 500 cPs for valve with springs
max. 50 cPs for auto-degassing metering pumps
max. 3000 cPs for high viscosity
01/06/2016 - Beta®
ProMinent® Beta® b
Solenoid Diaphragm Metering Pumps
Capacity Data
363
145
101
58
29
(25)
(10)
(7)
(4)
(2)
0.77
1.8
2.91
4.52
8.45
Shipping Weight
(higher weights
are for SS)
lbs
(kg)
73
145
116
145
116
116
50.5
29
14.5
(5)
(10)
(8)
(10)
(8)
(8)
(4)
(2)
(1)
0.22
0.4
0.37
0.74
0.66
1.14
2.22
3.75
5.52
(0.82)
(1.50)
(1.40)
(2.80)
(2.50)
(4.30)
(8.40)
(14.20)
(20.90)
0.08
0.13
0.13
0.24
0.24
0.4
0.78
1.31
1.94
19.6
19.6
19.6
19.6
19.6
19.6
19.6
9.8
6.5
(6.0)
(6.0)
(6.0)
(6.0)
(6.0)
(6.0)
(6.0)
(3.0)
(2.0)
180
180
180
180
180
180
180
180
180
1/4 x 3/16
1/4 x 3/16
1/4 x 3/16
1/4 x 3/16
1/4 x 3/16
1/4 x 3/16
1/2 x 3/8
1/2 x 3/8
1/2 x 3/8
6.4-­‐7.9
6.4-­‐7.9
6.4-­‐7.9
6.4-­‐7.9
6.4-­‐7.9
6.8-­‐8.6
6.8-­‐8.6
6.8-­‐8.6
7.3-­‐9.7
(2.9-­‐3.6)
(2.9-­‐3.6)
(2.9-­‐3.6
(2.9-­‐3.6)
(2.9-­‐3.6)
(3.1-­‐3.9)
(3.1-­‐3.9)
(3.1-­‐3.9)
(3.3-­‐4.4)
0.27
0.63
1.02
1.58
2.96
181
73
50.5
29
14.5
(13)
(5)
(4)
(2)
(1)
0.98
2.19
3.46
5.05
9.56
(3.70)
(8.30)
(13.10)
(19.10)
(36.20)
0.34
0.76
1.21
1.77
3.35
19.6
19.6
13.1
9.8
6.5
(6.0)
(6.0)
(4.0)
(3.0)
(2.0)
180
180
180
180
180
(8 x 4mm)
1/2 x 3/8
1/2 x 3/8
1/2 x 3/8
1/2 x 3/8
9.9-­‐11.7
9.9-­‐11.7
9.9-­‐11.7
10.4-­‐12.8
11.2-­‐14.6
(4.5-­‐5.3)
(4.5-­‐5.3)
(4.5-­‐5.3)
(4.7-­‐5.8)
(5.1-­‐6.6)
BT4b: auto-­‐degassing liquid ends
1601
232 (16) 0.16 (0.59)
1602
232 (16) 0.37 (1.40)
1604
232 (16) 0.71 (2.70)
0708
101 (7)
1.74 (6.60)
0413
58 (4)
2.85 (10.80)
0220
29 (2)
4.28 (16.20)
0.06
0.13
0.25
0.61
1
1.5
116
116
116
50.8
29
14.5
(8)
(8)
(8)
(4)
(2)
(1)
0.21
0.46
0.95
1.98
3.33
4.76
(0.80)
(1.74)
(3.60)
(7.50)
(12.60)
(18.00)
0.07
0.174
0.33
0.69
1.17
1.67
5.9
6.9
8.8
6.5
6.5
6.5
(1.8)
(2.1)
(2.7)
(2.0)
(2.0)
(2.0)
180
180
180
180
180
180
1/4 x 3/16
1/4 x 3/16
1/4 x 3/16
1/2 x 3/8
1/2 x 3/8
1/2 x 3/8
6.4
6.4
6.8
6.8
6.8
7.3
(2.9)
(2.9)
(3.1)
(3.1)
(3.1)
(3.3)
73
51
29
(5)
(4)
(2)
1.98 (7.50) 0.69
3.25 (12.30) 1.14
4.6 (17.40) 1.61
9.8
8.2
8.2
(3.0) 180
(2.5) 180
(2.5) 180
1/2 x 3/8
1/2 x 3/8
1/2 x 3/8
9.9
9.9
10.4
(4.5)
(4.5)
(4.7)
pump spare parts &
accessories
BT5b: auto-­‐degassing liquid ends
1008
145 (10) 1.66 (6.30) 0.58
0713
101 (7)
2.77 (10.50) 0.97
0420
58 (4)
4.12 (15.60) 1.44
motor-driven
metering pumps
(2.90)
(6.80)
(11.00)
(17.10)
(32.00)
DULCOMETER®
instrumentation
Above capacities and suction lift refer to pumps tested on water at 115 VAC, 60 Hz, and an ambient temperature of 70°F (21°C).
Higher specific gravity fluids will reduce suction lift. Higher viscosity fluids will reduce capacity.
Liquid ends for highly viscous media have 10-­‐20% less metering capacity and are not self-­‐priming. Standard connectors are 1/2" MNPT or 5/8" hose barb. Positive suction recommended.
1
Not available with bleed valve.
2
SS versions use 1/4" female threads except models 0220, 0420, and 0232 which use 3/8" female threads.
3
Only available in SS and Acrylic liquid ends
Universal control cable necessary for external Beta control. (see page 145)
Materials In Contact With Chemicals
Liquid end materials in contact with media
Liquid End
*PVDF
Polypropylene
Acrylic PTFE with Carbon
316 Stainless Steel
Suction/Discharge valves
*PVDF
*PVDF
*PVDF
PTFE with Carbon
316 Stainless Steel
Seals
PTFE
PTFE
PTFE
PTFE
PTFE
Valve balls
Ceramic
Ceramic
Ceramic
Ceramic
Ceramic
Diaphragm*
PTFE
PTFE
PTFE
PTFE
PTFE
DULCOTEST®
sensors
Version
*PVT
PPT
NPT
TTT
SST
polymer blending &
dry feed solutions
*Highly compatible material suitable for most fluids. 01/06/2016 - Beta®
solenoid-driven
metering pumps
BT5b
25043
1008
0713
0420
02321
Max.
Tubing
Capacity at 1/2 Max. Backpressure Pre-­‐Primed SStroking
uction Lift Connectors2
U.S.
mL/
Rate
O.D. x l.D.
psig (bar) GPH (L/h) stroke ft
(m) spm
in
product
overview
Capacity Data: beta®b
Pump Version
Capacity at Max. Backpressure
U.S.
mL/
psig (bar) GPH (L/h) stroke
BT4b
1000
145 (10) 0.2 (0.74) 0.07
20013
290 (20) 0.25 (0.96) 0.1
1601
232 (16) 0.29 (1.10) 0.1
20023
290 (20) 0.45 (1.70) 0.19
1602
232 (16) 0.58 (2.20) 0.19
1604
232 (16) 0.95 (3.60) 0.33
0708
101 (7)
1.88 (7.10) 0.66
0413
58 (4)
3.25 (12.30) 1.14
0220
29 (2)
5.02 (19.00) 1.76
37
ProMinent® Beta® b
Solenoid Diaphragm Metering Pumps
Identcode Ordering System
BT4b
Beta 4b
Version Capacity
1000
2001
1601
0.20 gph (0.74 l/h), 145 psi (10 bar)
0.25 gph (0.96 l/h), 290 psi, (20 bar)
0.29 gph (1.10 l/h), 232 psi (16 bar)
1602
0.58 gph (2.2 l/h), 232 psi (16 bar)
Liquid end material:
PP
Polypropylene/PVDF, for self-degassing version Polypropylene/Polypropylene
2002
PV
TT
SS
product
overview
1604
0708
0413
0.45 gph (1.70 l/h), 290 psi (20 bar)
NP
0220
0.95 gph (3.60 l/h), 232 psi (16 bar)
1.88 gph (7.10 l/h), 102 psi (7 bar)
3.25 gph (12.30 l/h), 58 psi (4 bar)
5.02 gph (19.0 l/h), 29 psi (2 bar)
2504
1008
0713
0.77 gph (2.90 l/h), 363 psi (25 bar)
1.80 gph (6.80 l/h), 145 psi (10 bar)
2.91 gph (11.00 l/h), 102 psi (7 bar)
0232
8.45 gph (32.00 l/h), 29 psi (2 bar)
0420
4.52 gph (17.10 l/h), 58 psi (4 bar)
Acrylic glass/PVDF, for self-degassing version Acrylic glass/PVC
PVDF/PVDF
PTFE/PTFE
Stainless steel
O-rings:
E
B
T
solenoid-driven
metering pumps
P
EPDM/PTFE coated, only for PP and NP self-degassing
FPM-B/PTFE coated, only on PP and NP self-degassing
PTFE/PTFE coated
Diaphragm and seal EPDM
Liquid end version:
0
Non-bleed version, no valve spring, for TT, SS and type 0232 only
1
Non-bleed version, with valve spring, for TT, SS and type 0232 only
motor-driven
metering pumps
2
3
4
9
With deaerator, no valve spring, PP, PV, NP only, not type 0232
With deaerator, with valve spring, PP, PV, NP only, not type 0232
Version for highly viscous media, only PVT, types 1005, 1605, 0708, 1008, 0413, 0713, 0220, 0420
Self-degassing for PP, NP only, not for types 1000 and 0232
Hydraulic connections:
0
Standard according to technical data
B
special-connection 3/8" x 1/4"
Logo:
With ProMinent® logo
0
pump spare parts &
accessories
Power supply:
U
Universal 100-240 V
M
12-24 VDC
Cable and plug:
A
6 ft European
D
6 ft USA 115 V
U
6 ft USA 230 V
Relay:
0
No relay
1
Fault indicating relay, normally energized, 1 x changeover contact 230 V - 2 A
3
Fault indicating relay, normally de-energized, 1 x changeover contact 230 V - 2 A
4
As 1 + pacing relay 2 x normally open contacts 24 V - 100 mA
5
As 3 + pacing relay 2 x normally open contacts 24 V - 100 mA
Accessories:
0
No accessories
1
With foot and injection valve, 5 ft PVC suction tubing, 10 ft PE discharge tubing
Control type:
0
No lock
1
With lock: manual operation locked when external cable plugged in
Control variants:
0
Standard
BT4b
1000
PP
E
0
0
0
U
A
0
0
0
0
polymer blending &
dry feed solutions
DULCOTEST®
sensors
DULCOMETER®
instrumentation
Beta 5b
Version Capacity
Version Capacity
38
01/06/2016 - Beta®
ProMinent® Beta® b
Solenoid Diaphragm Metering Pumps
Dimensional Drawings
Dimensions in inches (mm).
Ranges given, actual dimension dependent on liquid end material.
N
D
E
F
M
product
overview
.24x.16
(6x4)
C
solenoid-driven
metering pumps
B
H
A
J
I
K
G
Pump
A
B
C
E
F
G
3.7
(95)
H
I
J
K
L
M
N
BT4
3.6 3.1 .13-.75
(92) (80) (3.2-19)
5.8
(148)
7.0-7.8
(179-199)
5.2
(131.5)
3.2 .39
(81) (10)
1.4
(36)
2.8-3.0
(71-76)
3.2-3.7
2.8-4.3
1.1
(83-93) (Ø 90-Ø 110) 29.3
BT5
4.0 3.1 .13-.75 4.0
6.0
(102) (80) (3.2-19) (101) (153)
7.0-7.8
(179-199)
5.3
(135.5)
3.3 .59
(85) (15)
1.6
(41)
2.8-3.0
(71-76)
3.2-3.7
2.8-4.3
1.1
(83-93) (Ø 90-Ø 110) 29.3
motor-driven
metering pumps
D
L
pump spare parts &
accessories
With Auto-Degassing Liquid Ends
N
C
D
E
F
M
DULCOMETER®
instrumentation
A
J
I
H
K
L
G
A
B
C
D
E
3.7
(95)
F
G
H
I
J
K
L
M
N
BT4
3.6 3.1 .30-.75
(92) (80) (7.5-19)
5.8
(148)
6.7-7.42
5.2
(170.5-188.5) (131.5)
3.2 .39
(81) (10)
1.4
(36)
2.9-3.0
(74-77)
3.5-4.2
2.8-3.5
1.73
(89-105.5) (Ø 90-Ø 70) 43.9
BT5
4.0 3.1 .30-.75 4.0
6.0
(102) (80) (7.5-19) (101) (153)
6.7-7.42
5.3
(170.5-188.5) (135.5)
3.3 .59
(85) (15)
1.6
(41)
2.9-3.0
(74-77)
3.5-4.2
2.8-3.5
1.73
(89-105.5) (Ø 90-Ø 70) 43.9
01/06/2016 - Beta®
39
polymer blending &
dry feed solutions
Pump
DULCOTEST®
sensors
B
ProMinent® gamma/ X
Solenoid Diaphragm Metering Pumps
Overview: gamma/ X
The gamma/ X solenoid diaphragm metering pump incorporates a wealth of eXcellent ingenuity!
With integrated pressure measurement, it ensures the smooth running of your metering process. The
gamma/ X is ideal for all chemical metering applications.















motor-driven
metering pumps

solenoid-driven
metering pumps

product
overview

Capacity range from 0.24 GPH to 11.9 GPH, maximum discharge pressure up to 363 psi
Simple adjustment of the capacity directly in GPH
Configurable discharge stroke, continuous or pulsed dosing
Configurable suction stroke duration
Stroke rate adjustable from 1 – 12,000 strokes per hour
Electronic stroke length adjustment, continuous from 0 - 100% (recommended range 30 - 100%)
Suitable for continuous micro-metering from 1 ml/hr thanks to the innovative solenoid control
Integrated pressure measurement allows for detection of blocked discharge line, broken discharge
lines and air or gas bubbles trapped in the dosing head
Acrylic/PVC, PVT (PVDF) and Stainless Steel liquid end material versions
Auto degassing liquid ends in Acrylic/ PVC and PVT
High viscosity liquid ends (PVT4) for viscosities of up to 3000 cP
Large backlit graphic display and status LED’s with 360° visibility
External control via voltage-free contacts with pulse multiplier/divider function
External control via standard 4-20 mA signal, and scalable adjustment of mA signal to stroke rate
Standard internal programmable timer for real-time dependent dosing routines i.e biocides,
cooling towers etc.
Standard pump capable of accepting 2-stage tank level sensor input, flow monitor input,
diaphragm rupture sensor input and control cable input.
NSF/ANSI 61 Approved Liquid ends
Bluetooth, PROFIBUS, CANbus interface as an optional feature
pump spare parts &
accessories
DULCOMETER®
instrumentation
DULCOTEST®
sensors
polymer blending &
dry feed solutions
01/06/2016 - gamma/ X
41
ProMinent® gamma/ X
Solenoid Diaphragm Metering Pumps
Capacity Data
DULCOMETER®
instrumentation
pump spare parts &
accessories
motor-driven
metering pumps
solenoid-driven
metering pumps
product
overview
gamma/X
Pump
CapacityatMaximumBackpressure
Version
Max.
Stroking
Rate
psig (bar) GPH* (l/h) ml/stroke Strokes/min
gamma/Xwithstandardliquidends
1602
232 (16) 0.61 (2.3) 0.19
200
1604
232 (16) 0.95 (3.6) 0.30
200
0708
102 (7)
2.0
(7.6) 0.63
200
0414
58
(4)
3.56 (13.5) 1.17
200
0220
29
(2)
5.2
(19.7) 1.64
200
2504
363 (25) 1.0
(3.8) 0.32
200
1009
145 (10) 2.38 (9.0) 0.75
200
0715
102 (7)
3.83 (14.5) 1.21
200
0424
58
(4)
6.34 (24)
2.00
200
0245
29
(2)
11.9 (45)
3.70
200
gamma/Xwithauto-degassingliquidendsNPB9/NPE9
1602
232 (16) 0.34 (1.30) 0.11
200
1604
232 (16) 0.63 (2.40) 0.21
200
0708
101 (7)
1.8
(6.80) 0.57
200
0414
58
(4)
3.17 (12)
1.00
200
0220
29
(2)
4.75 (18)
1.5
200
1009
145 (10) 2.11 (8)
0.67
200
0715
101 (7)
3.56 (13.5) 1.00
200
0424
58
(4)
5.28 (20)
1.67
200
gamma/Xwithauto-degassingliquidendsPVT7
1602
232 (16) 0.24 (0.9) 0.075
200
1604
232 (16) 0.41 (1.55) 0.13
200
0708
101 (7)
1.50 (5.7) 0.48
200
0414
58
(4)
3.17 (12)
1.00
200
0220
29
(2)
4.60 (17.4) 1.45
200
1009
145 (10) 1.58 (6.0) 0.50
200
0715
101 (7)
3.40 (12.9) 1.08
200
0424
58
(4)
5.07 (19.2) 1.60
200
Tubing
SuctionLift**
Connectors
O.D.xl.D
SSLiquidend Shipping
connections Weightlbs
FNPT
in
ft
(m)
in
NP/PV SS
1/4x3/16
1/4x3/16
1/2x3/8
1/2x3/8
1/2x3/8
(8x4mm)
1/2x3/8
1/2x3/8
1/2x3/8
1/2x3/8
19.6
19.6
19.6
19.6
19.6
19.6
19.6
9.8
6.5
6.5
(6)
(6)
(6)
(6)
(6)
(6)
(6)
(3)
(2)
(2)
1/4
1/4
1/4
1/4
3/8
1/4
1/4
1/4
3/8
3/8
7.9
7.9
8.1
8.1
8.1
10.8
11.2
11.2
11.2
11.5
9
9
11
11
11
12.1
14.3
14.3
14.3
15.4
1/4x3/16
1/2x3/8
1/2x3/8
1/2x3/8
1/2x3/8
1/2x3/8
1/2x3/8
1/2x3/8
6.9
8.9
6.5
6.5
6.5
9.8
8.2
8.2
(2.1)
(2.7)
(2)
(2)
(2)
(3)
(2.5)
(2.5)
~
~
~
~
~
~
~
~
7.9
7.9
8.1
8.1
8.1
11.2
11.2
11.2
~
~
~
~
~
~
~
~
1/4x3/16
1/4x3/16
1/2x3/8
1/2x3/8
1/2x3/8
1/2x3/8
1/2x3/8
1/2x3/8
6
6
6
6
6
6
6
6
(1.8)
(1.8)
(1.8)
(1.8)
(1.8)
(1.8)
(1.8)
(1.8)
~
~
~
~
~
~
~
~
7.9
7.9
8.1
8.1
8.1
11.2
11.2
11.2
~
~
~
~
~
~
~
~
gamma/Xmeteringpumpswithhighviscosityliquidends(PVT4)havea10–20%lowercapacityratingandarenotself-priming.Positivesuction
isrecommendedandpumpssuppliedwith½”MNPTconnections.
*Thegivenperformancedatarepresentsguaranteedminimumvalues,calculatedusingwaterasthemediumatroomtemperature.
**Suctionliftwithafilleddosingheadandfilledsuctionline,withaself-bleedingdosingheadwithairinthesuctionline
polymer blending &
dry feed solutions
DULCOTEST®
sensors
Alldatareferstowaterat68°F
Materials In Contact With Chemicals
Liquidendmaterialsincontactwithmedia
NPE
NPB
PVT
SST
Pumphead
ClearAcrylic
ClearAcrylic
PVDF
StainlessSteel
Suction/dischargevalve
PVC
PVC
PVDF
StainlessSteel
Ballseat
EPDM
FKM
PVDF
Ceramic
Seals
EPDM
FKM
PTFE
PTFE
Balls
Ceramic
Ceramic
Ceramic
Ceramic
Auto-degassingliquidendsinNPwithavalvespringmadeofHastelloyCandaPVDFvalveinsert.PVT7versionwithPVDF/PTFEwettedparts.
DiaphragmwithaPTFEface.
Permissibleambienttemperature:14°F-113°F⎮Averagepowerconsumption:25/30W⎮Degreeofprotection:IP66/NEMA 4X
FKM=fluorinerubber
42
01/06/2016 - gamma/ X
ProMinent® gamma/ X
Solenoid Diaphragm Metering Pumps
Specifications
For 70mm solenoid approx. .05”
For 85mm solenoid approx. .06”
Fibreglass reinforced PPE (Polyphenylene Ether)
PTFE faced EPDM with plastic core
Acrylic/PVC, PVDF, Stainless Steel
IP 65
100 – 230 VAC 1 Phase 50 / 60 Hz ± 10%
1602 / 1604 / 0708 / 0414 / 0220 25 W
2504 / 1009 / 0715 / 0424 / 0245 30 W
Double ball suction / discharge (PVT4 with spring loaded single ball)
6ft
6ft
product
overview
pump spare parts &
accessories
14 °F to 113 °F
-4 °F to 140 °F
Material Constant
Short Term*
Acrylic/PVC 113 °F
140 °F
PVDF
113 °F
248 °F
SS
113 °F
248 °F
*15 minutes at 29 psi maximum
95% Relative humidity – non-condensing
LpA < 70 dB according to EN ISO 20361
2 years on pump drive, 1 year on liquid end
NP / PVT M20 x 1.5 (provided with adapters for tubing)
All pumps are tested for capacity at maximum pressure prior to
shipment
Versions 1602 / 1604 / 2504 = 15μ
Versions 0708 / 0414 / 0220 / 1009 / 0715 / 0424 / 0245 = 50 μ
motor-driven
metering pumps
Relay contact rated 230 VAC 2 A Max
Both relay contacts rated 24 V, 100 mA Max
Isolated 4 – 20 mA output can drive up to 300 Ω maximum impedance
Relay contact rated 24 V 100 mA
solenoid-driven
metering pumps
DULCOMETER®
instrumentation
20 ms
25 pulses / second
120 Ohms
Max. 200 cPs for standard liquid end
Max. 500 cPs for valve with springs
Max. 50 cPs for auto-degassing liquid ends
Max. 3000 cPs for high-viscosity liquid ends
DULCOTEST®
sensors
Maximum stroke length:
Materials of construction
Housing:
Diaphragm:
Liquid end options:
Enclosure rating:
Power supply:
Power consumption:
Check valves:
Power cord:
Relay cable (optional):
Relay Options
Identcode Option 1:
Identcode Option 4:
Identcode Option C:
Ambient temperature range
In operation:
Storage & Transport:
Max. fluid operating temp:
Climate:
Sound pressure level:
Warranty:
Valve threads:
Standard production test:
Max solids size in fluid:
Contact input
Minimum pulse duration:
Maxiumum pulse input:
Analog Input Impedance:
Recommended Viscocity:
polymer blending &
dry feed solutions
01/06/2016 - gamma/ X
43
ProMinent® gamma/ X
Solenoid Diaphragm Metering Pumps
Identcode Ordering System
GMXa Gamma/ X
Version Capacity
Version Capacity
1602 0.61 gph (2.3 l/h), 232 psi (16 bar) 0220 5.2 gph (19.7 l/h), 29 psi (2 bar)
1604
0.95 gph (3.6 l/h), 232 psi (16 bar)
2504
1.0 gph (3.8 l/h), 363 psi (25 bar)
0708
2.0 gph (7.6 l/h), 102 psi (7 bar)
1009
2.38 gph (9.0 l/h), 145 psi (10 bar)
0414
3.56 gph (13.5 l/h), 58 psi (4 bar)
0715
3.8 gph (14.5 l/h), 102 psi (7 bar)
Version Capacity
0424 6.34 gph (24 l/h), 58 psi (4 bar)
0245
11.9 gph (45 l/h), 29 psi (2 bar)
Liquid end material:
Clear acrylic /PVDF, for self-degassing version Clear acrylic / PVC
PV
PVDF/PVDF
SS*
Stainless Steel
O-rings:
E
EPDM/PTFE (PP and NP, self-bleeding design)
B
FKM-B/PFTE (PP and NP, self-bleeding design)
T
PTFE/PFTE
S
Diaphragm additionally with FKM coating for siliceous media, FKM-B seals on PP and NP, PTFE on TT, PV and SS
Liquid end version:
0
Non-bleed version, no valve spring only with NP, TT and SS and type 0245
1
Non-bleed version, with valve spring only with NP, TT and SS and type 0245
2
Bleed function, no valve springs only with PP, PV, NP not for type 0245
3
Bleed function, with valve springs only with PP, PV, NP not for type 0245
4
Version for highly viscous media only with PV, types 1604, 0708, 0414, 2504, 1009, 0715, 0424
7
Auto degassing without bypass, only with PV, not for versions 2504 and 0245
9
self-degassing with bypass (SEK), only with PP/NP, not for types 2504 and 0245
Hydraulic connections:
motor-driven
metering pumps
solenoid-driven
metering pumps
product
overview
NP
D
1/4" x 3/16"
E
3/8" x 1/4"
F
1/2" x 1/4" for 2504 only
G
1/2" x 3/8"
Diaphragm rupture indicator:
0
Without diaphragm rupture indicator
1
With diaphragm rupture indicator, optical sensor
Version:
0
Standard
Logo:
pump spare parts &
accessories
0
Standard, with logo
Electrical Connection:
U
100-230 V, ±10 %, 50/60 Hz
Cable and plug with 6ft (2m) power cord, single phase:
A
European plug
D
N. American plug, 115 V
U
N. American plug, 230 V
DULCOMETER®
instrumentation
Relay, pre-set to:
0
Without relay
1
1 x changeover contact 230 V – 2 A, fault indicating relay N/C
4
2 x N/O 24 V – 100 mA, such as 1 + pacing relay
C
1 x N/O 24 V – 100 mA, such as 1 + 4 – 20 mA output
F
G
Auto degassing module (not available for version 2504 )
Auto degassing module + fault relay (not available for version
2504), comes with panel
Accessories:
0
Not included (for PVDF, TT, SS)
1
With foot and injection valve, 5 ft PVC suction tubing, 10 ft PE
discharge tubing
DULCOTEST®
sensors
Control Variants:
0
Manual + external 1:1 with pulse control
3
Manual + external with pulse control + analogue 0/4 - 20 mA
4
Options 0 + 4 week process timer
5
Options 3 + 4 week process timer
C*
Options 3 + CANopen
R
Options 3 + PROFIBUS® DP interface, M12
−
no relay with PROFIBUS® version
Metering Monitor:
polymer blending &
dry feed solutions
0
Pulse signal input
Bluetooth connection:
0
Without connection
B
With connection
Language:
0
GMXa
1601
PP
E
1
0
0
0
0
U
D
1
0
3
0
0
Standard
0
Note: * Available 2016
44
01/06/2016 - gamma/ X
ProMinent® gamma/ X
Solenoid Diaphragm Metering Pumps
Dimensional Drawings
D
4.40
E
ØA
C
B
.59
.59
1.50
5.32
solenoid-driven
metering pumps
.82
.20
3.15
4.60
7.80
B
3.00
3.00
2.91
2.91
2.80
2.80
C
−
4.33
4.21
4.25
4.17
4.17
D
.55
.95
.95
.95
1.25
1.25
E
8.22
7.95
7.95
7.95
7.80
7.80
B
3.00
3.00
3.00
2.91
3.03
3.03
C
4.13
4.09
4.09
4.01
4.13
4.13
D
.55
.90
.90
.90
1.30
1.30
E
8.27
7.87
7.87
7.87
7.52
7.52
B
3.00
3.11
2.87
2.95
2.80
2.80
C
−
3.50
3.50
3.62
3.31
3.31
D
.55
.98
.98
.98
1.42
1.42
E
8.22
8.00
8.00
8.00
7.72
7.72
pump spare parts &
accessories
ØA
4.30
3.50
3.50
3.50
2.75
2.75
motor-driven
metering pumps
Material design PPT
Type
0245
0424, 0220
0715, 0414
1009, 0708
1604
1602
Material design NPT
ØA
4.30
3.50
3.50
3.50
2.75
2.75
DULCOMETER®
instrumentation
Type
0245
0424, 0220
0715, 0414
1009, 0708
1604
1602
polymer blending &
dry feed solutions
01/06/2016 - gamma/ X
ØA
4.30
3.50
3.50
3.50
2.75
2.75
DULCOTEST®
sensors
Material design PVT
Type
0245
0424, 0220
0715, 0414
1009, 0708
1604
1602
product
overview
8.50
.43
45
ProMinent® gamma/ L
Solenoid Diaphragm Metering Pumps
Overview: gamma/ L
Ideal for applications requiring automation, large turndown and/or
feed verification
(see page 132 for spare parts and page 145 for control cables)
 Capacity range 8.4 gph (32 l/h) max, 290 psi (20 bar) max
 Continuous stroke length adjustment from 0-100%
 Supplied in PP, Acrylic/PVC, PTFE, PVDF, SS
 Patented bleed valve on PP, PVDF, and Acrylic/PVC versions
product
overview
 Auto-degassing liquid end version in Acrylic/PVC
 HV liquid end for highly viscous media (suitable for viscosities to 3000 cPs)
 Digitally accurate stroke rate via keypad and large LCD display
 Select feed rate display in strokes/min. or gph
 Programmable pressure levels
 Flow monitor input
solenoid-driven
metering pumps
 External Control: Voltage free contact, pulse m/d and/or 4-20 mA input
 Interface for PROFIBUS® DP (see page 145)
 Two-stage float switch connector
 Optional 14-day programmable timer with software for PC programming
 12-24 V DC, 24 V AC low voltage version
 LED’s for operational status
motor-driven
metering pumps
 Concentration entry option for proportional flow metering
 NSF/ANSI 61 approved
pump spare parts &
accessories
DULCOMETER®
instrumentation
DULCOTEST®
sensors
polymer blending &
dry feed solutions
pk_1_005
01/06/2016 - gamma/ L
47
ProMinent® gamma/ L
Solenoid Diaphragm Metering Pumps
Overview: gamma/ L
The gamma/L is a diaphragm-type, solenoid-driven, microprocessor based metering pump with maximum
capacities to 8.4 gph (32.0 L/h) and maximum backpressure to 290 psig (20 bar).
ProMinent® solenoid-driven metering pumps consist of two main components: the pump drive unit and the
liquid end.
pump spare parts &
accessories
motor-driven
metering pumps
solenoid-driven
metering pumps
product
overview
Drive Unit
The pump housing is constructed of fiberglass-reinforced PPE plastic to protect against corrosion, dust,
and water.
The solenoid drive unit houses a short-stroke solenoid with a maximum stroke length of 0.05” (1.25 mm). It is
equipped with a noise suppressing mechanism for quiet operation and the armature is the only moving part.
Operating on pulse action, each pulse generates a magnetic field in the solenoid coil. This magnetic field
moves the armature, which in turn moves the diaphragm. The diaphragm pushes into the dosing head and
cavity forces chemical out of the discharge valve. When the magnetic field is de-energized, a spring returns
the armature and diaphragm to their original position. This return movement draws chemical into the dosing
head cavity through the suction valve.
In the event of a diaphragm rupture, the liquid end has a weep hole on the bottom of the backplate to direct
chemical out of the pump and away from the solenoid. An optional diaphragm failure detector can be used
to stop the pump and indicate a fault.
The stroke-length adjusting mechanism is connected directly to the solenoid. Adjustment results in an
accurate self-locking stroke-length setting.
Diaphragm
The diaphragm is constructed of
fabric-reinforced EPDM elastomer with a plastic core and PTFE-facing. It is chemically resistant to virtually
all process fluids and can be used over a wide temperature range. The gamma/ L pump is designed with a
convex diaphragm. The curved shape
provides precise metering and alleviates stress placed on the diaphragm by reducing liquid end dead
volume.
DULCOMETER®
instrumentation
Cutaway view of ProMinent gamma/ L solenoid-driven metering pump
4
9
5
6
10
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
8
DULCOTEST®
sensors
12
2
polymer blending &
dry feed solutions
3
11
7
48
Housing
Liquid end
Diaphragm
Backplate
Solenoid
Solenoid coil
Solenoid axle
Armature
Cover
Stroke adjustment screw
Stroke adjustment axle
Stroke adjustment knob
1
01/06/2016 - gamma/ L
ProMinent® gamma/ L
Solenoid Diaphragm Metering Pumps
Overview: gamma/ L
The Liquid End
The gamma/ L metering pump liquid ends are available in five material versions: Polypropylene (PP), Kynar
(PVDF), Acrylic/PVC (NP), PTFE (TT), and 316 Stainless steel (SS).
Options include a manual bleed valve with needle valve for easy priming, and continuous bleed of fluids that
tend to off-gas (available with versions PP, PVT, and NP liquid ends).
High viscosity PVDF liquid ends are available for pump versions 1005, 0708, 0413, 0220, 1008, 0713, and
0420. Their metering capacity is 10-20% less than standard pump versions and recommended viscosity is
up to 3000 cPs. The HV liquid ends are not self-priming; flooded suction is recommended.
Discharge
AutoDegassing
Discharge
Bleed
Valve
Liquid end without
bleed valve
Discharge
Suction
motor-driven
metering pumps
Suction
solenoid-driven
metering pumps
Suction and discharge ports are equipped with double-ball check valves for superior repeatability.
Suction
Liquid end with bleed
valve
Auto-degassing
liquid end
The gamma/ L metering pumps accept a universal 100-230 volt power supply (+/- 10%), single phase, 50/60
Hz, with a 1.15 service factor. Performance is identical whether operated on 50 Hz or 60 Hz power. The
power cord is detachable.
Fault Indicators
Fault annunciating relay
STROKE LENGTH
ADJUSTMENT KNOB
WARNING INDICATOR
(YELLOW)
UP KEY
OPERATING INDICTOR
(GREEN)
PROGRAM KEY
INFORMATION
KEY
DOWN KEY
“FLOW MONITOR” TERMINAL
STOP/START KEY
“FLOAT SWITCH” TERMINAL
Pacing relay
01/06/2016 - gamma/ L
“EXTERNAL CONTROL”
TERMINAL
polymer blending &
dry feed solutions
A contact closure is issued with
every pump stroke (contact duration
150 ms). This allows a second
ProMinent metering pump to be
paced synchronously, or to totalize flow
with an external stroke counter.
DULCOTEST®
sensors
For low tank level (level switch),
processor fault, fuse/power supply
failure, Flow monitor, Analog (loss of
signal), and Calibration
DULCOMETER®
instrumentation
Three LED lights indicate operational status. A green light flashes during normal operation; a yellow light
warns of low chemical; and a red
light indicates lack of chemical or an
FAULT INDICATOR
ILLUMINATED
operational error.
(RED)
LCD DISPLAY
pump spare parts &
accessories
Power Supply
Relay Outputs
product
overview
Automatic degassing liquid ends are available for PP and NP versions (except 1000 and 0232). This style
liquid end discharges from the center and degasses from the top to prevent air build-up in the chamber.
Recognized
Available
49
ProMinent® gamma/ L
Solenoid Diaphragm Metering Pumps
Standard Modes and Functions
polymer blending &
dry feed solutions
DULCOTEST®
sensors
DULCOMETER®
instrumentation
pump spare parts &
accessories
motor-driven
metering pumps
solenoid-driven
metering pumps
product
overview
Feed rate is determined by stroke
length and stroke rate. Stroke length
is manually adjustable from 1 to100%
in increments of 1% via the stroke
length knob. Optimum repeatability is
between 30-100% or 50-100% when
using an auto-degassing liquid end.
Stroke rate can be set to a maximum
of 180 strokes per minute. An
illuminated LCD displays stroke
length, stroke rate and an
accumulative strokecounter, that can
be cleared and reset.
Standard Functions
“Calibrate”
The pump can be directly
calibrated in-line to determine output
on standard liquid ends and 50% to
100% on auto-degassing liquid ends.
A warning indicator flashes when
adjustments to the stroke volume are
made outside the calibrated range of
(+/- 10%) of stroke length.
“Pause”
The gamma/ L series can be switched
on or off via a dry contact through the
optional control cable. This function
operates only via the “external
control” terminal.
“Stop”
The gamma/ L can be stopped by
pressing the STOP/START.
“Pressure Level”
“Prime”
Pump capacity output is displayed
in either U.S. gph or l/h, set by the
operator. Totalized capacity is also
displayed in either U.S. gallons or
litres.
Backpressure control can be adjusted
depending on maximum psig of
pump version.
Priming is activated by pressing both
arrow keys at the same time.
The “i” key is used to scroll
information screens for stroke rate,
stroke length, stroke counter,
capacity and totalized capacity. Other
information is available
depending on options ordered.
An auxiliary frequency can be
programmed. This default value can
be enabled via an optional control
cable.
Basic Control Modes
The gamma/ L series metering pumps
will monitor their own output with the
optional adjustable flow monitor
connected to the discharge valve.
Every fluid discharge is sensed and
fed back to the electronic control
circuit of the pump. If insufficient fluid
is discharged for a predetermined
number of strokes (up to 125), the
pump automatically stops and the
red LED illuminates. The optional fault
relay changes state to issue an alarm
or activate a standby pump.
Five control modes are available with
the gamma/ L: manual, external
contact 1:1, externalcontact with
pulse control (multiplier/divider),
batch or analog control. The basic
version includes manual and external
contact 1:1. The PROFIBUS® option
includes all control modes, plus
fieldbus connection.
In the “Manual” mode, stroke rate is
controlled manually. The “Contact”
external 1:1 mode allows adjustments
to be made externally (e.g. by means
of a pulse-type water meter for
proportional chemical feed). Pulse
signals are fed into the contact input
of the pump by an optional control
cable. Each pulse from a water meter
or pulse-type controller produces
one pump stroke, up to the pump’s
maximum stroke rate. Over-stroking
the pump is not possible.
Note: Universal Control Cable
necessary for all gamma/ L control
capabilities. (See Accessories page
145 cables)
50
“Auxiliary Frequency”
“Flow”
Function and Errors
Indicators
Three LED lights on the pump
faceplate signal operational status.
The green light flashes during normal
operation and the yellow light warns
of a situation that could lead to a
fault (e.g., low chemical). If a fault
occurs “ERROR” will appear on the
LCD screen and the red LED light is
illuminated.
“Float Switch”
An optional two-stage ProMinent
float switch can be plugged into the
pump to monitor chemical levels in
the source tank. An early warning is
issued when the allowable minimum
level is reached. The pump continues
to operate while the display flashes,
the yellow LED illuminates and an
optional fault relay changes state to
issue an alarm. If the liquid level in
the supply tank drops another 3/4”
(20 mm), the pump automatically
shuts down, the LCD displays
“Minim” and the red LED illuminates.
The optional fault relay remains
activated.
01/06/2016 - gamma/ L
ProMinent® gamma/ L
Solenoid Diaphragm Metering Pumps
Optional Modes and Functions
Optional Control Modes
Access Code
“Analog” Mode
A programmable access code to
prevent unauthorized changes to
settings is available as an option.
Relay outputs
Fault annunciating relay
For low tank level (float switch), loss
of flow (flow monitor), system faults
and fuse/power supply failure.
Fault annunciating and Pacing relay
“Contact” Mode with Pulse
Control
By simply entering a factor in the
0.01-99.99 range, the step-up or
step-down ratio is set.
Step-up Factor:
99.991pulse = 99.99 pump strokes
10 1pulse = 10 pump strokes
Step-down Factor:
0.25 4pulses= 1 pump stroke
0.01 100pulses= 1 pump stroke
Fieldbus connection
Monitor and control remotely via
a SCADA/PLC system using the
PROFIBUS®-DP system.
i
01/06/2016 - gamma/ L
Accumulative strokes (*N)
Accumulative quantity (*gal or *L)
mA current (mA)
Pulse factor / Memory (*)
Indication of external mode (EXT)
51
polymer blending &
dry feed solutions
Stroke rate (frequency)
Stroke length (percent)
Stroke counter (N)
Capacity (gph or l/h)
Dosing quantity (gal or L)
DULCOTEST®
sensors
The Batch mode is a variation of the
contact operating mode. A specific
4-20 mA Analog Output
Note: Relay options not available
number of strokes can be entered up
with PROFIBUS®. PROFIBUS® is not
to 65,535 strokes (whole numbers)
A 4-20 mA analog output option is
field
retrofittable.
or the feed quantity can be entered.
available for use with pumps that
The batch is then initiated by either
operate in the manual mode or by a
pressing the “P” key on the pump
face or providing a contact to
iNFORMATION DISPLAYS
the external control cable. Note:
Pulse control is needed to run the
Mode dependent
All modes
batch mode.
DULCOMETER®
instrumentation
An external panel in the base of the
pump enables optional relays to be
installed on-site.
pump spare parts &
accessories
The range of applications exceeds
that of a “standard timer”. Typical
applications are disinfection in
cooling towers, process water, etc.,
with the ability to automatically
program shock dosages or increase
the concentration at a certain
interval.
For example:
“Batch” Mode
The optional integrated 14-day timer
offers 81 programmable events. It
can be set to hourly, daily,
workdays, weekend, weekly or twoweek periods with switch-on times
from 1 second to two weeks. The
timer can be programmed to change
operation mode, frequency, and the
function of two relays. All the
functions can be programmed
independently of one another. Up to
13 delay times can be programmed
into the timer function.
motor-driven
metering pumps
Pulse step-up (multiply) and
step-down (divide)
Timer Relay
solenoid-driven
metering pumps
This feature is used to “tune” the
gamma/L to contact generators of
any kind (e.g., pulse-type water meter
or process controller), and eliminates
the need for a costly external control
unit. The following functions can be
selected by means of the keypad.
In addition to the fault annunciating
relay, a contact closure is issued with
every pump stroke (contact
duration 150 ms). This allows a
second ProMinent metering pump to
be paced synchronously, or to totalize
flow with an external stroke counter.
product
overview
With this option, the stroke rate of
the gamma/L is directly proportional
to the analog signal. The maximum
number of strokes per minute
corresponding to the analog signal
range can be selected by the
operator. Input signals can be set to
4-20 mA , or a custom curve.
remote 4-20 mA analog signal. The
4-20 mA analog output signal is
linear to pump frequency multiplied
by the percentage of stroke length.
The output signal is isloated and can
drive up to 300 Ohms impedance.
Analog output can be used for status
feedback to higher level control
systems for closed loop control or
for monitoring chemical usage. This
option is available in combination
with either the fault annunciating or
pacing relay.
ProMinent® gamma/ L
Solenoid Diaphragm Metering Pumps
polymer blending &
dry feed solutions
DULCOTEST®
sensors
DULCOMETER®
instrumentation
pump spare parts &
accessories
motor-driven
metering pumps
solenoid-driven
metering pumps
product
overview
Specifications
Maximum stroke length:
Materials of construction
Housing:
Diaphragm:
Liquid end options:
Enclosure rating:
Motor insulation class:
Power supply:
100-230 VAC, 1 phase, 50/60 Hz, +/- 10%; 12-24 VDC or 24 VDC (+/- 10%)
Check valves:
Double ball
Metering repeatability:
0.05” (1.25 mm)
Fiberglass reinforced PPE
PTFE-faced EPDM with plastic core
Polypropylene, PVDF, Acrylic/PVC, PTFE, 316 SS
IP 65
F
When used according to operating instructions, ±2% under constant conditions and at minimum 30% stroke length. The minimum stroke length with auto-degassing liquid end is 50%.
Power cord:
6 ft (2 m)
Relay cable (optional):
6 ft (2 m)
Relay load
Fault relay only (options 1 & 3):
Contact load: 250 VAC, 2 A, 50/60 Hz
Operating life: > 200,000 switch functions
Fault and pacing relay (Options 4 & 5):
Contact load: 24 V, 2 A, 50/60 Hz
Operating life: > 200,000 switch functions
Residual impedance in ON-position (RDSOn): < 8 W
Residual current in OFF-position: <1mA
Maximum voltage: 24 VDC
Maximum current: < 100 mA (for pacing relay)
Switch functions: 15x109
Contact closure: 100 µs (for pacing relay)
Analog output signal:
Max. impedance 300 W
Isolated 4-20 mA output signal
14°F (-10°C) to 113°F (45°C)
Ambient temperature range:
Max. fluid operating temperatures:
Average power drain at maximum
stroke rate (Watts) / current
drain at pump stroke (Amps)
1000, 1601, 1602, 1005,
0708, 0413, & 0220:
1605, 1008, 0713, 0420 & 0230:
Material
Acrylic/PVC
Polypropylene
PVC
PVDF
PTFE
316 SS
Service factor:
1.15
Warranty:
Industry standards:
Valve threads:
Standard Production Test:
Max. solids size in fluid:
Controlling contact (pulse):
Necessary contact duration:
Recommended Viscocity:
52
Constant
113°F (45°C)
122°F (50°C)
113°F (45°C)
149°F (65°C)
122°F (50°C)
122°F (50°C)
Short Term
140°F (60°C)
212°F (100°C)
140°F (60°C)
212°F (100°C)
248°F (120°C)
248°F (120°C)
17W / 0.7 A or 15 A (peak current for approx. 1 µs)
22W / 1.0 A or 15 A (peak current for approx. 1 µs)
2 years on drive, 1 year on liquid end (extended warranties available)
UL Recognized in United States and Canada, CE available, NSF/ANSI 61
NP, PP, PVT, and TT Versions: M20 x 1.5 (provided with tubing adapters)
All pumps are tested for capacity at maximum pressure prior to shipment.
Pumps with 1/4” valves: 15µ - Pumps with 1/2” valves: 50µ
With voltage free contact, or with semiconductor sink logic control (NPN), not source logic
(PNP). With a residual voltage of <0.7 V, the contact load is approximately 0.5 mA at +5 VDC.
(Note: Semiconductor contacts that require >0.7 V across a closed contact should not be used.)
Pump ignores contacts exceeding maximum input rate.
20 µS
max. 200 cPs for standard liquid end
max. 500 cPs for valve with springs
max. 50 cPs for auto-degassing liquid ends
max. 3000 cPs for high-viscosity liquid ends
01/06/2016 - gamma/ L
ProMinent® gamma/ L
Solenoid Diaphragm Metering Pumps
Capacity Data
CapacityData:gamma/L
Pump
Version
Pre-Primed Max.
CapacityatMax.Backpressure
U.S.
psig
(bar) GPH
(L/h)
Tubing
ShippingWeight
2
Capacityat1/2Max.Backpressure Suction
Stroking Connectors
mL/
U.S.
mL/
Lift
Rate
O.D.xl.D.
stroke psig (bar) GPH (L/h) stroke ft
(m) spm
in
(higherweightsareforSS)
lbs
(kg)
73
(5)
0.21
(0.82) 0.08
19.6 (6)
180
1/4x3/16
7.5-8.6
(3.4-3.9)
0.26
0.29
(0.98)
(1.1)
0.1
0.1
145
126
(10)
0.37
(8.75) 0.37
(1.4) 0.13
(1.4) 0.13
19.6 (6)
19.6 (6)
180
180
1/4x3/16
1/4x3/16
6.4-7.9
7.5-8.6
(2.9-3.6)
(3.4-3.9)
2002
1602
1005
0708
0413
0220
1605
1008
0713
0420
3
290
232
145
101
58
29
232
145
101
58
(20)
(16)
(10)
(7)
(4)
(2)
(16)
(10)
(7)
(4)
0.45
0.55
1.1
1.9
3.2
5
1.1
1.8
2.9
4.5
(1.7)
(2.1)
(4.4)
(7.1)
(12.3)
(19.0)
(4.1)
(6.8)
(11.0)
(17.1)
0.19
0.19
0.41
0.66
1.14
1.76
0.38
0.63
1.02
1.58
145
126
73
50.5
29
14.5
126
73
50.5
29
(10)
(8.75)
(5)
(3.50)
(2)
(1)
(8.75)
(5)
(3.50)
(2)
0.66
0.66
1.32
2.22
3.75
5.52
1.29
2.19
3.46
5.04
(2.5)
(2.5)
(5)
(8.4)
(14.2)
(20.9)
(4.9)
(8.3)
(13.1)
(19.1)
19.6
19.6
19.6
19.6
9.8
6.5
19.6
19.6
13.1
9.8
(6)
(6)
(6)
(6)
(3)
(2)
(6)
(6)
(4)
(3)
180
180
180
180
180
180
180
180
180
180
1/4x3/16
1/4x3/16
1/2x3/8
1/2x3/8
1/2x3/8
1/2x3/8
1/2x3/8
1/2x3/8
1/2x3/8
1/2x3/8
6.4-7.9
7.5-8.8
7.7-9.0
7.7-11.0
7.7-11.0
7.7-11.0
9.3-10.8
9.5-12.8
9.5-12.8
9.5-12.8
(2.9-3.6)
(3.4-4.0)
(3.5-4.1)
(3.5-5.0)
(3.5-5.0)
(3.5-5.0)
(4.2-4.9)
(4.3-5.8)
(4.3-5.8)
(4.3-5.8)
02321
29
(2)
8.4
(32.0)
2.96
14.5 (1)
9.56
(36.2) 3.35
6.5
(2)
180
1/2x3/8
11.2-14.6
(5.1-6.6)
(0.59)
(1.4)
(3.6)
(6.6)
(10.8)
(16.2)
(3.3)
(6.3)
(10.5)
(15.6)
0.055
0.13
0.33
0.61
1
1.5
0.31
0.58
0.97
1.44
126
126
73
50.5
29
14.5
126
73
50.5
29
0.21
0.45
1.05
1.98
3.3
4.7
1
1.98
3.2
4.6
(0.78)
(1.7)
(4)
(7.5)
(12.6)
(18.0)
(3.8)
(7.5)
(12.3)
(17.4)
5.9
6.9
8.8
6.5
6.5
6.5
9.8
9.8
8.2
8.2
(1.8)
(2.1)
(2.7)
(2)
(2)
(2)
(3)
(3)
(2.5)
(2.5)
180
180
180
180
180
180
180
180
180
180
1/4x3/16
1/4x3/16
1/2x3/8
1/2x3/8
1/2x3/8
1/2x3/8
1/2x3/8
1/2x3/8
1/2x3/8
1/2x3/8
7.7
7.7
7.7
7.7
7.9
7.9
9.5
9.5
9.5
9.5
(3.5)
(3.5)
(3.5)
(3.5)
(3.6)
(3.6)
(4.3)
(4.3)
(4.3)
(4.3)
Auto-degassingliquidends
1601
232
(16)
0.16
1602
232
(16)
0.37
1005
145
(10)
0.95
0708
101
(7)
1.74
0413
58
(4)
2.8
0220
29
(2)
4.3
1605
232
(16)
0.87
1008
145
(10)
1.66
0713
101
(7)
2.77
0420
58
(4)
4.12
(8.75)
(8.75)
(5)
(3.50)
(2)
(1)
(8.75)
(5)
(3.50)
(2)
0.24
0.24
0.46
0.78
1.31
1.94
0.45
0.76
1.21
1.77
0.07
0.16
0.37
0.69
1.17
1.67
0.35
0.69
1.14
1.61
(Note:Abovecapacitiesandsuctionliftrefertopumpstestedonwaterat115VAC,60Hz,andanambienttemperatureof70oF(20oC).Higherspecific
gravityfluidswillreducesuctionlift.Capacitieswillbeslightlyreducedfrompublishedratingsifpumpsareskidmounted.)
Higherviscosityfluidswillreducecapacity.Liquidendsforhighlyviscousmediahave10-20%lessmeteringcapacityandarenotself-priming.
Standardconnectorsare1/2”MNPTor5/8”hosebarb.Positivesuctionisrecommended.
1
Notavailablewithbleedvalve.
2
SSversionsuse1/4”femalethreadsexceptmodels0220,0420,and0232whichuse3/8”femalethreads.
pump spare parts &
accessories
0.07
(20)
(16)
motor-driven
metering pumps
(0.74)
290
232
solenoid-driven
metering pumps
0.19
20013
1601
product
overview
Standardliquidends
1000
145
(10)
3
OnlyavailableinSSandAcrylicliquidends.
DULCOMETER®
instrumentation
Materials In Contact With Chemicals
Liquid end materials in contact with media
Pump head
Polypropylene
Polypropylene
Acrylic
Acrylic
PVDF
PTFE with carbon
stainless steel
Suction/Pressure connector
Polypropylene
Polypropylene
PVC
PVC
PVDF
PTFE with carbon
stainless steel
O-­‐rings
EPDM
Viton®
EPDM
Viton®
PTFE
PTFE
PTFE
Balls
ceramic
ceramic
ceramic
ceramic
ceramic
ceramic
ceramic
DULCOTEST®
sensors
PPE
PPB
NPE
NPB
PVT
TTT
SST
polymer blending &
dry feed solutions
Auto-­‐degassing version available in PP and NP only. Supplied with Hastelloy C valve springs, PVDF valve core.
Pump diaphragm with PTFE-­‐coating.
Note: Viton® is a registered trademark of DuPont Dow Elastomers.
01/06/2016 - gamma/ L
53
ProMinent® gamma/ L
Solenoid Diaphragm Metering Pumps
Identcode Ordering System
GALa
Gamma/ L
Version Capacity
2001 0.26 gph (0.98 l/h), 290 psi (20 bar)
1601 0.29 gph (1.1 l/h), 253 psi (17.5 bar)
2002 0.53 gph (1.7 l/h), 290 psi (20 bar)
1602 0.55 gph (2.1 l/h), 232 psi (17.5 bar)
1605* 1.1 gph (4.1 l/h), 253 psi (17.5 bar)
1000 0.19 gph (0.74 l/h), 145 psi (10 bar)
Liquid end material:
1005*
1.1 gph (4.4 l/h), 145 psi (10 bar)
0708*
1.9 gph (7.1 l/h), 101 psi (7 bar)
1008*
0713*
0413*
0420*
Version Capacity
0220*
1.8 gph (6.8 l/h), 145 psi (10 bar)
0232
3.2 gph (12.3 l/h), 58 psi (4 bar)
NP
Acrylic glass/PVDF, for self-degassing version Acrylic glass/PVC
TT
SS
PVC
PVDF/PVDF
PTFE/PTFE
Stainless Steel
O-rings:
E
EDPM o-rings (PP, NP)
Viton® o-rings (PP, NP)
B
T
P
V
solenoid-driven
metering pumps
8.4 gph (32.0 l/h), 29 psi (2 bar)
4.5 gph (17.1 l/h), 58 psi (4 bar)
Polypropylene/PVDF, for self-degassing version Polypropylene/Polypropylene
PV
5.0 gph (19.0 l/h), 29 psi (2 bar)
*Versions available with high viscosity liquid ends
2.9 gph (11.0 l/h), 101 psi (7 bar)
PP
PC
product
overview
Version Capacity
PTFE o-rings (PVDF, TT, SS)
EPDM diaphragm with DPDM o-rings (PP, NP)
Viton® diaphragm with Viton o-rings (PP, NP)
Viton® is a registered trademark of DuPont Dow Elastomers
Liquid end version:
0
Non-bleed version, no valve spring, for TT, SS and type 0232 only
1
Non-bleed version, with valve spring, for TT, SS and type 0232 only
2
With bleed valve, no valve spring, PP, PV, NP only, not type 0232
3
With bleed valve, with valve spring, PP, PV, NP only, not type 0232
Version for highly viscous media, only PVT, types 1005, 1605, 0708, 1008, 0413, 0713, 0220, 0420
4
DULCOTEST®
sensors
DULCOMETER®
instrumentation
pump spare parts &
accessories
motor-driven
metering pumps
9
Self-degassing for PP, NP only, not for types 1000 and 0232
Hydraulic connections:
0
Standard according to technical data
NOTE: Connector option 6 must be used on all pumps with standard 1/2" x 3/8" tubing
connections, and it may be used on pumps with 1/4" x 3/16" tubing connectors. Use option
6
1/2" x 3/8" tube fittings
0 on all pumps with standard NPT connections and for high viscosity.
B
special-connection 3/8" x 1/4"
Logo:
0
Standard, with logo
Electrical Connection (± 10%):
M
12-24 VDC (versions 1000-0220)
N
24 VDC (versions 1605-0232)
U
Universal 100-240 V
Cable and plug with 6ft (2m) power cord, single phase:
A
European plug
D
N. American plug, 115 V
U
N. American plug, 230 V
1
Open ended (for low voltage options M and N)
Relay:
0
Without relay (Required with Profibus)
1
Fault annunciating relay, drops out
3
Fault annunciating relay, pulls in
4
Option 1 + pacing relay
5
Option 3 + pacing relay
C
Option 1 + 4-20 mA analog output
D
Option 3 + 4-20 mA analog output
E
Pacing relay + 4-20 mA analog output
Accessories:
0
Not included (for PVDF, TT, SS)
1
With foot and injection valve, 5 ft PVC suction tubing, 10 ft PE discharge tubing
Control Variants:
0
Manual + External 1:1
1
Manual + External with pulse control (multiplier/divider)
2
Manual + External 1:1 with analog control
3
Manual + External with pulse control & analog control
4
Option 0 + Timer
5
P
Option 3 + Timer
Option 3 + PROFIBUS (Relay must be 0)
Access Code:
0
No Access Code
polymer blending &
dry feed solutions
1
Access Code
Flow Monitor:
0
GALa
54
1601
SS
T
1
0
0
U
D
1
0
3
0
0
Input for metering monitor signal (pulse)
Pause/Float:
0
Standard
0
01/06/2016 - gamma/ L
ProMinent® gamma/ L
Solenoid Diaphragm Metering Pumps
Dimensional Drawings
Dimensions in inches (mm).
Ranges given, actual dimension dependant on liquid end material.
H
product
overview
G
C
solenoid-driven
metering pumps
B
F
A
E
D
PumpA
B
C
D
E
F
G
H
motor-driven
metering pumps
GALa
4.03.16.33.3-4.3
2.8-3.1
5.8
6.4-8.5
0.5-0.6
(102)(80) (160)(85-110)(71-80) (147)
(162-217)
(12-14)
pump spare parts &
accessories
With Auto-Degassing Liquid Ends
DULCOMETER®
instrumentation
H
G
C
J
F
DULCOTEST®
sensors
B
E
D
PumpA
B
C
D
E
F
G
HJ
polymer blending &
dry feed solutions
GALa
4.03.16.33.5-3.6
2.9-3.0
5.8
6.7-7.4
1.7
4.0
(102)(80) (160)(89-92)(74-77) (147)
(177-189)
(44)
(101)
01/06/2016 - gamma/ L
55
ProMinent® delta®
Solenoid Diaphragm Metering Pumps
Overview: delta®
Ideal for applications requiring metering pump accuracy with minimal
pulsation
(see page 138 for spare parts and page 145 for control cables)
 Continuous or pulsating dosing
 Configurable suction and delivery stroke duration
 Pump can be adapted to the dosing media
 Capacities: 2.0 gph (7.5 lph) to 19.8 gph (75.0 l/h)
 Stroke length continuously adjustable from 0 - 100% (recommended range 30 - 100%)
product
overview
 Integrated optoGuard monitoring detects blocked dosing points, broken dosing lines and air
or gas bubbles trapped in the dosing head
 Acrylic, PVDF and stainless steel material versions
 Patented bleed
 Adjustment and display of pump delivery from the keypad with choice of display in l/h or
strokes/min
 Optional external auto-degassing solenoid kit available for outgassing media
 Large backlit graphic display
 External control options via voltage-free contacts with optional increase/reduce speed pulse
solenoid-driven
metering pumps
 Optional detection and indication of diaphragm failure
 Optional external control via standard 0/4-20 mA signal
motor-driven
metering pumps
 Interfaces for PROFIBUS® DP (see page 145) or CAN bus system
 14-day process timer option for time and event-dependent dosing duties
 Connections for 2 stage-level switch and flow monitor
 3 LED displays for operation and warning and error message in plain text
 Optional concentration input for volume-proportional dosing
 NSF/ANSI 61 approved
pump spare parts &
accessories
DULCOMETER®
instrumentation
DULCOTEST®
sensors
polymer blending &
dry feed solutions
pk_1_131_2
01/06/2016 - delta®
57
ProMinent® delta®
Solenoid Diaphragm Metering Pumps
Capacity Data
Capacity data: delta®
2508
1608
1612
1020
0730
0450
0280
Max. strokes/ Pre-­‐primed suct. lift
Capacity at Maximum Backpressure min.
GPH
(L/h)
psig
(bar)
spm
ft
(m)
2
(7.5)
363
(25)
200
19.6
(5)
2.1
(7.8)
232
(16)
200
16.4
(5)
3
(11.3) 232
(16)
200
19.6
(6)
4.8
(18.0) 145
(10)
200
16.4
(5)
7.7
(29.2) 102
(7)
200
16.4
(5)
12.9
(49.0) 58
(4)
200
9.8
(3)
19.8
(75.0) 29
(2)
200
6.7
(2)
Shipping weights (higher weights are for SST)
Suction/Discharge connectors
in
lbs
(kg)
3/8” x 1/2” (1/2” MNPT dis. only) 22-­‐24
(10-­‐11)
3/8” x 1/4”
22-­‐24
(10-­‐11)
3/8” x 1/4” 22-­‐24
(10-­‐11)
1/2” x 3/8”
22-­‐24
(10-­‐11)
1/2” x 3/8”
22-­‐24
(10-­‐11)
5/8” ID hose barb standard1
22-­‐24
(10-­‐11)
5/8” ID hose barb standard1
22-­‐24
(10-­‐11)
Above capacities and suction lift refer to pumps tested on water at 115 VAC, 60 Hz, and an ambient temperature of 70°F (21°C).
Higher specific gravity fluids will reduce suction lift. Higher viscosity fluids will reduce capacity.
1
(1/2” MNPT optional)
Materials In Contact With Chemicals
Liquid end materials in contact with media Suction/Discharge valves
Version
Liquid End
*PVDF
*PVT
*PVDF
SST
316 SS
316 SS
NPE
Acrylic
PVC
NPB
Acrylic
PVC
Seals
PTFE
PTFE
EPDM
Viton®
Valve balls
Ceramic
Ceramic
Ceramic
Ceramic
Diaphragm*
PTFE
PTFE
PTFE
PTFE
*Highly compatible material suitable for most fluids.
Viton® is a registered trademark of DuPont Dow Elastomers. polymer blending &
dry feed solutions
DULCOTEST®
sensors
DULCOMETER®
instrumentation
pump spare parts &
accessories
motor-driven
metering pumps
solenoid-driven
metering pumps
product
overview
Pump Version
58
01/06/2016 - delta®
ProMinent® delta®
Solenoid Diaphragm Metering Pumps
Identcode Ordering System
DLTA
delta
Version Capacity
Version Capacity
2508
2.1 gph (7.5 l/h), 362 psi (25 bar)
1612
3.0 gph (11.30 l/h), 232 psi (16 bar)
1608
1020
0730
2.1 gph (7.8 l/h), 232 psi (16 bar)
0450
0280
5.05 gph (19.1 l/h), 145 psi (25 bar)
7.7 gph (29.20 l/h), 101.5 psi (7 bar)
13 gph (49 l/h), 58 psi (4 bar)
19.8 gph (75 l/h), 29 psi (2 bar)
Liquid end materials:
PV
PVDF (for models 1608, 1612, 1020, and 0730)
NP
Acrylic glass/PVC (for pump type 2508, 1608, 1612, 1020 & 0730)
SS
SS
O-rings:
PTFE seals
B
Viton® o-rings (NP only)
product
overview
T
E
EPDM o-ring (NP only)
Liquid end version:
0
W/o bleed valve, w/o spings (for SS liquid ends)
2
With bleed valve, w/o springs
4
W/o bleed valve, with springs (for high viscosity only)
1
3
With bleed valve, with springs
W/o liquid end
Connection:
1/2" x 3/8" tubing (for models 1020 & 0730); 5/8" hose barb (for models 0450 & 0280); 3/8" x 1/4" tubing (for models 1608 & 1612)
0
6
1/2" MNPT Connections (for models 0450, 0280 & 2508)
Diaphragm failure indicator:
0
1
Without diaphragm failure indicator
With diaphragm failure indicator
Logo:
Standard, with ProMinent® logo
motor-driven
metering pumps
0
Electrical connection (± 10%)
U
115-230 V, 50/60 Hz
Cable and plug with 6 ft (2 m) power cord, single phase:
A
D
U
European plug
N. American plug, 115 V
N. American plug, 230V
Relay:
0
Without relay (Required with PROFIBUS)
3
Fault annunciating relay, pulls in
4
5
A
C
G
Fault annunciating relay, drops out
Option 1 + pacing relay
Option 3 + pacing relay
Alarm indication + pump shut off
Option 1 + 4-20 mA analog output + fault output (24V 100 mA max.)
Auto-degassing valve + fault relay (not available for version 2508)
Accessories:
0
Not included
1
Foot Valve, Inj Valve, 15' Tubing (3/8" x 1/4") PVDF (for model 1612)
1
1
1
1
Foot Valve, Inj Valve, 15' Tubing (3/8" x 1/4") PVC (for model 1608)
Foot Valve, Inj Valve, 15' Tubing (1/2" x 3/8") PVC (for model 1020)
Foot Valve, Inj Valve, 15' Tubing (1/2" x 3/8") PVDF (for model 0730)
Foot Valve, Inj Valve, 5' Suction Tubing (1/2" x 3/8") PVC
(1/2" MNPT on Discharge) (for model 2508)
FV, IV, 15' House (5/8" ID) PVDF (for models 0450 & 0280)
Control Variants:
0
Manual + External contact (multiplier/divider)
4
Option 0 + 14 day timer
3
M
R
Manual + External with pulse control & analog control
Option 3 + 14 day timer
with pH,ORP and chlorine control module
Option 3 + Profibus M12 (Relay must be 0)
Access Code:
0
1
No Access Code
Access Code
Language:
EN
English
Pause/Float:
01/06/2016 - delta®
0
0
0
0
0
U
A
0
0
0
0
EN
Standard
polymer blending &
dry feed solutions
0
PV
DULCOTEST®
sensors
5
DULCOMETER®
instrumentation
1
2508
pump spare parts &
accessories
1
DLTA
solenoid-driven
metering pumps
X
W/o bleed valve, with springs ( for SS liquid ends)
0
59
ProMinent® delta®
Solenoid Diaphragm Metering Pumps
Dimensional Drawings
Dimensions in inches (mm).
Ranges given, actual dimension dependent on liquid end material.
Dimensions of delta® type 1612 - 0730 PVT
9.4 (238)
.51 (13)
2.24 (57)
.28 (7)
5.4 (138)
4.7 (120)
4.3 (109)
7.5 (191)
5.5(140)
5.1 (129)
dimensions in inches (mm)
Dimensions of delta® type 0450 - 0280 PVT
1.0 (26)
polymer blending &
dry feed solutions
9.6 (244)
2.6 (65)
5.9 (150)
DULCOTEST®
sensors
9.4 (238)
Ø 106
DULCOMETER®
instrumentation
pump spare parts &
accessories
motor-driven
metering pumps
3.0 (75)
5.9 (150)
9.0 (228)
solenoid-driven
metering pumps
Ø 90
product
overview
.98 (25)
.51 (13)
2.2 (57)
.28 (7)
4.7 (120)
5.5 (140)
5.4 (138)
7.5 (191)
4.5 (115)
5.2 (133)
dimensions in inches (mm)
60
01/06/2016 - delta®
ProMinent® delta®
Solenoid Diaphragm Metering Pumps
Dimensional Drawings
Dimensions of delta® type 1612 - 0730 SST
Ø 3.3 (Ø 84.5)
10 (252)
6 (150)
motor-driven
metering pumps
1.8 (47)
2.2 (57)
0.2 (7)
4.4 (113)
5.4 (138)
43 (120)
7.5 (191)
5.5 (140)
solenoid-driven
metering pumps
9.4 (238)
product
overview
0.5 (12.5)
5.0 (128)
dimensions in inches (mm)
pump spare parts &
accessories
Ø 3.9 (Ø 100)
10.5 (268)
6 (150)
DULCOTEST®
sensors
1.2 (31)
0.5 (13)
polymer blending &
dry feed solutions
2.2 (57)
0.2 (7)
43 (120)
5.5 (140)
5.4 (138)
7.5 (191)
4.5 (115)
5.1 (131)
5.3 (136)
dimensions in inches (mm)
01/06/2016 - delta®
DULCOMETER®
instrumentation
9.4 (238)
Dimensions of delta® type 0450 - 0280 SST
61
ProMinent® mikro delta®
Piston Metering Pumps
Overview: mikro delta®
Ideal for applications requiring metering pump accuracy with minimal
pulsation
 Feed rate range 0.04 gph (150 ml/h) to 0.4 gph (1500 ml/h)
 Stroke volume 1 - 250 μl
 Material versions PTFE and stainless steel
product
overview
 Metering reproducibility: ± 0,5 %
 Continuous or pulsing operation
 Adaptation of the pump to the feed chemical
 Continuous stroke length adjustment from 0 - 100 %
 Adjustment and display of the feed rate, either as strokes/min or ml/h via the keyboard
solenoid-driven
metering pumps
 Large illuminated graphic display
 External activation via potential-free contacts with pulse step-up and step-down
 External activation by standard signal 0/4-20 mA (optional)
 Interface for PROFIBUS® or CANopen (optional)
 Interfaces for PROFIBUS® DP (see page 145) or CAN bus system
 1 month process timer for time- and event-dependent metering tasks (optional)
 Connection for 2-stage level switch
motor-driven
metering pumps
 Optional concentration input for volume-proportional dosing
 3 LED display for operation, warning and error messages in plain text
 Concentration input for volume-proportional metering
pump spare parts &
accessories
Further technical details on request
The mikro delta® is a solenoid-driven precision piston metering pump for dosing
solutions in millilitre range. The controlled solenoid drive enables continuous
dosing of smallest amounts and single stroke dosing up to a volume of 1 μl/stroke.
The maximum stroke length of the modified delta® solenoid drive is 5 mm. The
stroke frequency is infinitely
DULCOMETER®
instrumentation
adjustable from 1 stroke/h up to 100 strokes/min. A nearly continuous dosing can
be realised from approx. 20 strokes/h, this corresponds to a stroke length of 3
minutes.
DULCOTEST®
sensors
By means of the piston-type liquid ends of the preceding pump series mikro G/5
the same delivery rates are reached at half stroke length and double stroke
frequency, however at higher pressure from 60 to 20 bar for stainless steel liquid
ends and 10 bar for PTFE liquid ends.
pk_1_010
polymer blending &
dry feed solutions
Liquid end
62
The mikro delta® is available in three sizes with piston diameters of 2.5, 5 and 8
mm at a maximum stroke volume of 25, 100 and 250 μl. The sealing material is
either PTFE pure white or PTFE with carbon. The material PTFE with carbon is
recommended when the media to be dosed has no lubricating properties itself and
traces of carbon have no disadvantage for the process. Double ball valves made of
Ruby/Ceramic and the integrated back pressure valve ensure constant and
pressure independent dosing from zero up to a maximum back pressure of 60 bar
with a reproducibility better than 0.5 %. The dosing capacity is 1 – 250 μl/stroke
and 0.001 – 1,500 ml/h
01/06/2016 - delta®
ProMinent® mikro delta®
Piston Metering Pumps
Capacity Data
Capacity at Maximum Backpressure
ml/h
psig (bar)
μl/
stroke
Pre-primed
suct. lift
ft
(m)
100150 TT
100600 TT
101500 TT
600150 SS
400600 SS
201500 SS
145
580
1,480
145
580
1,480
145
145
145
870
580
290
24.2
96.7
246.7
24.2
96.7
246.7
19.6
19.6
13.1
19.6
19.6
13.1
(10)
(10)
(10)
(60)
(40)
(20)
Suction/Discharge
connectors
mm
(6)
(6)
(4)
(6)
(6)
(4)
1.75 x 1.15 1.75 x 1.15
3.20 x 2.40
1.75 x 1.15
1.75 x 1.15
3.20 x 2.40
Shipping weights
(higher weights
are for SS)
lbs
(kg)
22-24
22-24
22-24
22-24
22-24
22-24
(10-11)
(10-11)
(10-11)
(10-11)
(10-11)
(10-11)
Note: Universal control cable necessary for external delta control. (see page 145)
Materials In Contact With Chemicals
Suction/Pressure Valve Valve
connection ballsseats
Plunger Gaskets
TTT
PTFE / carbon
PTFE / carbon
ruby
ceramic
ceramic
PTFE, White
SST
SS 1.4571
PTFE / carbon
ruby
ceramic
ceramic
PTFE, Graphite
TTG
SS 1.4571
PTFE / carbon
PTFE / carbon
ruby
ruby
ceramic
ceramic
ceramic
ceramic
PTFE, Graphite
PTFE, Graphite
Spare Parts
Spare Plunger
Type
Part no.
100600/400600803181
101500/201500803182
PTFE Packing (White)
Part no.
100600/400600485430
101500/201500485432
PTFE Packing (Graphite)
100150/600150485428
100600/400600485427
101500/201500485429
01/06/2016 - delta®
63
polymer blending &
dry feed solutions
Part no.
DULCOTEST®
sensors
100150/600150485431
Type
DULCOMETER®
instrumentation
100150/600150803149
Type
pump spare parts &
accessories
SSG
PTFE / carbon
motor-driven
metering pumps
VersionDosing
Head
solenoid-driven
metering pumps
(Note: Above capacities and suction lift refer to pumps tested on water at 115 VAC, 60 Hz, and an ambient temperature of
70*F (20*C). Higher specific gravity fluids will reduce suction lift. Capacities will be slightly reduced from published ratings
if pumps are skid mounted).
product
overview
mikro
delta®
Pump Type ProMinent® mikro delta®
Piston Metering Pumps
Identcode Ordering System
MDLa
mikro delta® series, version a
Version
100150
600150
100600
Capacity
145 ml/h, 145 psi (10 bar) *Only TT
145 ml/h, 870 psi (60 bar) *Only SS
580 ml/h, 145 psi (10 bar) *Only TT
Liquid end materials:
Version
400600
101500
201500
product
overview
SS Stainless steel
TT PTFE with 25 % carbon
O-rings:
T PTFE pure white
G PTFE with graphite
solenoid-driven
metering pumps
Liquid end version:
0 no valve spring
1 with valve spring
Connection:
0 Standard according to technical data
Logo:
with ProMinent®-Logo
no ProMinent®-Logo
motor-driven
metering pumps
Power Supply (± 10%):
U 115-230 V, 50/60 Hz
Cable and plug with 6 ft (2 m) power cord, single phase:
A European plug
D N. American plug, 115 V
U N. American plug, 230 V
pump spare parts &
accessories
Relay:
0 no relay
1 Fault indicating relay, normally energized, 1x changeover contact, 230 V - 8 A
3 Fault indicating relay, normally de-energized, 1 x changeover contact, 230 V - 8
4 A as 1 + pacing relay, 24 V - 100 mA
5 as 3 + pacing relay, 24 V - 100 mA
DULCOMETER®
instrumentation
Accessories:
no accessories
Control versions:
0 manual+external contact with pulse control
3 manual+external contact w/ pulse control+analogue 0/4-20 mA
4 as 0 + Process Timer (1 month)
5 as 3 + Process Timer (1 month)
C CANopen
R as 3 + PROFIBUS®-interface, M12
Security:
0 no access code
1 with access code
DULCOTEST®
sensors
polymer blending &
dry feed solutions
Capacity
580 ml/h, 580 psi (40 bar) *Only SS
1,480 ml/h, 145 psi (10 bar) *Only TT
1,480 ml/h, 290 psi (20 bar) *Only TT
Language:
EN English
MDLa
64
100150
SS
T
0
0
0
U D 0
0
0
0
Pause/Float:
0
Standard
EN
0
01/06/2016 - delta®
ProMinent® mikro delta®
Piston Metering Pumps
Dimensional Drawings
5.88 (149.5)
C
9.36 (237.8)
0.98 (25)
0.25 (6.5)
B
D
7.83 (198.9)
B
in (mm)
C
in (mm)
D
in (mm)
EØ
in (mm)
100150
9.60 (243.9)
5.90 (150.1)
4.13 (105.1)
6.26 (159.1)
1.92 (49)
101500
10.08 (256.2)
5.90 (150.1)
3.63 (92.3)
6.34 (161.1)
1.92 (49)
600150
10.08 (256.2)
5.90 (150.1)
3.63 (92.3)
6.34 (161.1)
1.92 (49)
201500
10.08 (256.2)
5.90 (150.1)
3.63 (92.3)
6.34 (161.1)
1.92 (49)
Version TT
100600
Version SS
400600
9.60 (243.9)
10.02 (254.7)
5.90 (150.1)
5.90 (150.1)
4.13 (105.1)
3.89 (99.0)
6.26 (159.1)
6.26 (159.1)
pump spare parts &
accessories
A
in (mm)
motor-driven
metering pumps
Type
2.24 (57)
7.72 (196.3)
5.51 (140)
solenoid-driven
metering pumps
4.72 (120)
product
overview
A
0.35 (9)
1.92 (49)
1.92 (49)
DULCOMETER®
instrumentation
DULCOTEST®
sensors
polymer blending &
dry feed solutions
01/06/2016 - delta®
65
ProMinent® EXtronic®
Solenoid Diaphragm Metering Pumps
Overview: EXtronic®
Ideal for explosion-proof applications
(see page 137 for spare parts)
The ProMinent EXtronic series represents a proven technology for metering liquid media in
hazardous areas classified in accordance with Zone 1 and in fire-damp-endangered mining
applications.
product
overview
 The new microprocessor control compensates for fluctuations in the power supply.
Automatic switchover from 50 Hz to 60 Hz operation with no change in capacity.
 Operating voltage of 500V increases the scope of application for ProMinent EXtronic
(e.g. in conjection with the new EXBb M version for fire-damp-endangered areas in mining applications).
pk_1_020
Stroke length adjustment 1:10, stroking
rate adjustment 1:25, total adjustment
range 1:250.
Factory Mutual Hazard Classification
Factory Mutual Research Corporation has certified that EXtronic series pumps are in compliance with explosion-proof classifications Class 1, Division 1, Groups B, C and D indoor
hazardous locations; and with intrinsically safe output connections for Class 1, Division
1, Groups A, B, C, and D hazardous locations. Installation must be in accordance with
manufacturer’s instructions and the National Electrical Code.
pk_1_019
CSA Approval
CSA approved for Class 1, Division 1, Groups B, C and D locations.
ProMinent EXtronic metering pumps are tested and classified in compliance with harmonized European Standards EN 50014/50018 for “flame-proof enclosure.” They have the
highest degree of protection in this type of enclosure class. This approval is recognized by
many other countries outside the EC member states.
The short-stroke solenoid and electronic control are integrated in the pump housing. The
enclsoure rating in accordance with DIN 40050, even with the front cover open.
The liquid end is equipped with a registered multi-layer (Teflon coated) pump diaphragm.
The liquid end is made of Acrylic, Polypropylene (PP), PTFE-Teflon, 316 stainless steel and
SB for flammable chemicals to ensure maximum operating safety.
Self-bleeding liquid ends made of Acrylic (NS) and PVC (PS) are available for off-gassing
fluids.
DULCOMETER®
instrumentation
pump spare parts &
accessories
Stroke length adjustment 1:10, stroking
rate control 0-100 % dependant upon
external switch contacts. *)
The micrometering adjusting knob for the stroke length enables precision setting of the
capacity and ensures a high degree of repeatability. A comprehensive range of explosionproof ancillary equipment and pump accessories is available.
0 - 20 mA
DULCOTEST®
sensors
 The control inputs “External Contact”, “Analog”, and “Zero Volts ON/OFF”are intrinsically safe for the EXBb-registered in accordance with EN 50020.
 The capacity range extends from 0.06 gph (0.19 L/h) to 15.8 gph (60 L/h) at backpressures of up to maximum 363 psig (25 bar).
Control type: “External Contact”
polymer blending &
dry feed solutions
 The short-stroke solenoid drive is combined with liquid ends from the ProMinent
gamma series. The material version SB material is recommended for use with flammable media.
 The 2501 SSM/SBM type is available with diaphragm failure detection
motor-driven
metering pumps
solenoid-driven
metering pumps
Control type “Internal”
pk_1_018
Control type: “Analogue”
Stroke length adjustment 1:10, Stoke
frequency control 0-100 % proportional to analogue signal 0/4-20 mA. *)
EXBb G for use in gas and fire damp hazardous areas
Degree of protection EEx [i,a] d IIC T6
EEX - Explosion-proof equipment built in accordance with European standards
[i,a] - Intrinsically safe control input in the case of two independent faults occurring
d - Flameproof enclosure protection
IIC - Explosion Group II for all hazardous areas apart from mines (includes IIA and IIB)
T6 - Temperature class approval for gases and vapours with ignition temperature > 85ºC
*) The electrical cables for mains connection, contact or analogue control
are already connected to the pump.
Observe all instructions concerning
connecting and activating electrical
systems.
EXBb M for use in hazardous mining operations
Degree of protection EEX d I/IIC T6
EEX - Explosion-proof equipment built in accordance with European standards
d- Flameproof enclosure protection
IC - Explosion Group I for firedamp-endangered mines
IIC - Explosion Group II for all other hazardous areas apart from mines (includes IIA and IIB)
T6 - Temperature class approval for gases and vapors with ignition temperature > 85ºC.
This is the highest temperature class; it includes T1 to T5.
66
01/06/2016 - Extronic
ProMinent® EXtronic®
Solenoid Diaphragm Metering Pumps
Specifications
Maximum stroke length:
0.026” (0.65 mm) for pump models 1000
0.049” (1.25 mm) for all other models
Materials of construction
Housing:
Diaphragm:
Epoxy coated die cast aluminum
PTFE faced EPDM with steel core
Liquid end options:
Enclosure rating:
Polypropylene, Acrylic/PVC, PTFE, 316 SS, high-viscosity Polypropylene
(IP 65); insulation class F
Mean power input at max. stroke frequency (W)/peak current
consumption for metering stroke (A) at 230V, 50/60 Hz
EXBb Type 1000, 1601, 1201, 0803, 1002, 0308: 23/25 W/0.9 A at 120
strokes/min.
EXBb Type 2502, 1006, 0613, 0417: 54/61 W/2.1 A at 120 strokes/min.
EXBb Type 2505, 1310, 1014, 0430, 0260: 77/83 W/3.1 A at 110 strokes/
min.
Thermal protection:
Check valves:
Yes
all models double ball except single ball on PP4 (HV) models
When used according to operating instructions, ±2%;
For type 1601 with self-degassing liquid end, ±5%.
Power cord:
6 ft. (2 m) 2 wire plus ground (no plug)
External control cable:
Ambient temperature range:
6 ft. (2 m) 2 wire
14°F (-10°C) to 113°F (45°C)
Material
Acrylic/PVC
Polypropylene
PTFE
316 SS
Max. allowable input current:
50 mA
Warranty:
Max. solids size in fluid:
Controlling contact (pulse):
Necessary contact duration:
Two years on drive; one year on liquid end.
Factory mutual (explosion-proof, intrinsically safe), CSA approved and
CE approved. EN 50014/50018; VDE 0170/0171-5.78,
100% tested for rated pressure and volume
Pumps with 1/4” valves: 15µ; pumps with 1/2” valve: 50µ
With voltage free contact, or with semiconductor sink logic control (NPN),
not source logic (PNP); with a residual voltage of <700 mV, the contact load
is approximately 20 mA at +10 VDC. (Note: Semiconductor contacts that
require >700 mV across a closed contact should not be used).
DULCOTEST®
sensors
Short Term
140°F (60°C)
212°F (100°C)
248°F (120°C)
248°F (120°C)
DULCOMETER®
instrumentation
Standard Production Test:
Constant
113°F (45°C)
122°F (50°C)
122°F (50°C)
122°F (50°C)
pump spare parts &
accessories
Max. fluid operating temperatures:
motor-driven
metering pumps
Repeatability:
Industry standards:
solenoid-driven
metering pumps
500V ±6%, 50/60 Hz
230V ±10%, 50/60 Hz
115V ±10%, 50/60 Hz
product
overview
Power supply:
100 ms
polymer blending &
dry feed solutions
01/06/2016 - Extronic
67
ProMinent® EXtronic®
Solenoid Diaphragm Metering Pumps
Capacity Data
Pump Version
Capacity at Max. Backpressure
EXBb
1000
2501
1601
1201
2502
10021
0803
2505
10061
0308
13101
0613
0814
0417
08141
0430
0260
psig
145
363
232
174
363
145
116
363
145
44
188
87
116
51
116
51
22
(bar)
(10)
(25)
(16)
(12)
(25)
(10)
(8)
(25)
(10)
(3)
(13)
(6)
(8)
(3.5)
(8)
(3.5)
(1.5)
GPH
0.05
0.26
0.26
0.45
0.53
0.61
0.98
1.11
1.59
2.27
2.77
3.46
3.7
4.6
3.7
7.13
15.85
(L/h)
(0.23)
(1.0)
(1.0)
(1.7)
(2.0)
(2.3)
(3.7)
(4.2)
(6.0)
(8.6)
(10.5)
(13.1)
(14.0)
(17.4)
(14.0)
(27.0)
(60.0)
mL/ stroke
0.03
0.15
0.14
0.23
0.28
0.31
0.51
0.64
0.83
1.2
1.59
1.82
2.12
2.42
2.12
4.09
9.09
Capacity at 1/2 Max. Backpressure
psig
73
290
116
87
290
73
58
290
73
22
87
44
58
29
58
29
-­‐
(bar)
(5)
(20)
(8)
(6)
(20)
(5)
(4)
(20)
(5)
(1.5)
(6)
(3)
(4)
(2)
(4)
(2)
(-­‐)
GPH
0.07
0.29
0.34
0.53
0.58
0.71
1.03
1.27
1.9
2.72
3.14
3.94
4.07
4.73
4.07
7.79
-­‐
(L/h)
(0.3)
(1.1)
(1.3)
(2.0)
(2.2)
(2.7)
(3.9)
(4.8)
(7.2)
(10.3)
(11.9)
(14.9)
(15.4)
(17.9)
(15.4)
(29.5)
(-­‐)
mL/ stroke
0.04
0.17
0.18
0.28
0.31
0.38
0.54
0.73
1
1.43
1.8
2.07
2.33
2.49
2.33
4.47
-­‐
Tubing Max. Shipping Weight Pre-­‐Primed Stroking Connectors2 (higher weights are Suction Lift Rate
O.D. x l.D.
for SS)
ft
19.6
19.6
19.6
19.6
5.9
19.6
19.6
6.5
6.9
9.8
6.5
8.8
9.8
6.5
9.8
9.8
8.2
(m)
(6)
(6)
(6)
(6)
(1.8)
(6)
(6)
(2)
(2.1)
(3)
(2)
(2.7)
(3)
(2)
(3)
(3)
(2.5)
spm
120
120
120
120
120
120
120
110
120
120
110
120
110
120
110
110
110
in
1/4 x 3/16
1/4 x 3/16
1/4 x 3/16
1/4 x 3/16
1/4 FNPT
1/2 x 3/8
1/4 x 3/16
1/4 FNPT
1/2 x 3/8
1/2 x 3/8
1/2 x 3/8
1/2 x 3/8
1/2 x 3/8
1/2 x 3/8
1/2 x 3/8
DN 10
DN 15
lbs
26.5-­‐35.3
39.7
26.5-­‐35.3
26.5-­‐35.3
28.7-­‐37.5
26.5-­‐35.3
26.5-­‐35.3
35.3-­‐44.1
28.7-­‐37.5
26.5-­‐35.3
35.3-­‐44.1
28.7-­‐37.5
35.3-­‐44.1
28.7-­‐37.5
35.3-­‐44.1
35.3-­‐44.1
35.3-­‐44.1
(kg)
(12-­‐16)
(18)
(12-­‐16)
(12-­‐16)
(13-­‐17)
(12-­‐16)
(12-­‐16)
(16-­‐20)
(13-­‐17)
(12-­‐16)
(16-­‐20)
(13-­‐17)
(16-­‐20)
(13-­‐17)
(16-­‐20)
(16-­‐20)
(16-­‐20)
Above capacities and suction lift refer to pumps tested on water at 115 VAC, 60 Hz, and an ambient temperature of 70°F (20°C).
Higher specific gravity fluids will reduce suction lift. Higher viscosity fluids will reduce capacity. Liquid ends for highly viscous media have 10-­‐20% less metering capacity and are not self-­‐priming. Standard connectors are 1/2” MNPT or 5/8” hose barb. Positive suction is recommended. 1
High Viscosity models are available in the 1002, 1006, 1310 and 0814 models. Liquid end designation is PP4 (Polypropylene/EPDM) Suitable for viscosities to 3500 cps
2
SS versions use 1/4” female threads except models 0220, 0420, and 0232 which use 3/8” female threads.
Capacity data: EXtronic® with Auto-­‐degassing Liquid Ends
Pump Version NS/PS
Capacity at Maximum Backpressure
EXBb
psig
(bar)
GPH
(L/h)
1601
232
(16)
0.17
(0.7)
1201
174
(12)
0.26
(1.0)
0803
116
(8)
0.63
(2.4)
1002
145
(10)
0.48
(1.8)
Max. Stroking Rate
mL/ stroke spm
0.09
120
0.14
120
0.33
120
0.25
120
Connectors Tube/NPT fitting PP/ NP/NS/PS/TT
in
1/4 x 3/16
1/4 x 3/16
1/4 x 3/16
1/4 x 3/16
Suction Lift
ft
(m)
5.9
(1.8)
6.6
(2.0)
9.2
(2.8)
6.6
(2.0)
Shipping Weight
Ibs
(kg)
27
(12)
27
(12)
27
(12)
27
(12)
Shipping Weight for EXBb Fireproof M Version is an additional 32 lbs. (14 kg).
polymer blending &
dry feed solutions
DULCOTEST®
sensors
DULCOMETER®
instrumentation
pump spare parts &
accessories
motor-driven
metering pumps
solenoid-driven
metering pumps
product
overview
Capacity data: EXtronic®
68
01/06/2016 - Extronic
ProMinent® EXtronic®
Solenoid Diaphragm Metering Pumps
Materials in Contact With Chemicals
Liquid end materials in contact with media
Liquid End
Polypropylene
Polypropylene
Acrylic
Acrylic
Acrylic
PVC PTFE with carbon PTFE with carbon
316 Stainless steel
Suction/Discharge Polypropylene
Polypropylene
PVC
PVC
PVC
PVC
PTFE with carbon
PTFE with Carbon
316 Stainless Steel
Seals
EPDM
EPDM
Viton®
Viton®
Viton®
Viton®
PTFE
PTFE
PTFE
Valve balls
Ceramic
Ceramic
Ceramic
Ceramic
Ceramic
Ceramic
Ceramic
Ceramic
Ceramic3
Diaphragm
PTFE
PTFE
PTFE
PTFE
PTFE PTFE
PTFE
PTFE
PTFE
product
overview
Version
PP1
PP41
NP1
NP3
NS32
PS32
TT1
TTT
SS
1
PP4 with Hastelloy C valve springs.
NS3 and PS3 with Hastelloy C valve springs, PVDF valve core. NOTE: Viton® is a registered trademark of DuPont Dow Elastomers.
3
DN 10 and DN 15 valve balls are 316 stainless steel 2
solenoid-driven
metering pumps
Factory Mutual System
approved
Approved
(standard in Canada)
Approved
motor-driven
metering pumps
The EXtronic metering pumps are registered according to DIN-VDE 0170/01715.78.
pump spare parts &
accessories
DULCOMETER®
instrumentation
DULCOTEST®
sensors
polymer blending &
dry feed solutions
01/06/2016 - Extronic
69
ProMinent® EXtronic®
Solenoid Diaphragm Metering Pumps
Identcode Ordering System
EXBb
Enclosure Type:
G
M
Explosion protection
Fire and explosion protection: permissible liquid end material - PTFE & Stainless Steel
Version: Capacity:
Version: Capacity:
1000
0.05 gph, 145 psi
0613
1201
0.45 gph, 174 psi
2501*** 0.26 gph, 363 psi
1601
0803
0.61 gph, 145 psi
2502*
0.53 gph, 363 psi
1006
1.59 gph, 145 psi
3.46 gph, 87 psi
4.6 gph, 50.8 psi
1.11 gph, 363 psi
1310**
2.77 gph, 189 psi
0260v
7.13 gph, 50.8
15.8 gph, 21.8 psi
0814
0430v
Liquid end materials:
*Type 2502 & 2505 only available in SS and SB
**Type 1310 only avaiable in NP, PP4, SS and SB
***Type 2501 available in SSM and SBM only
vType 0430 & 0260 not available in SS2
3.7 gph, 116 psi
PP1
PP4
Polypropylene with EPDM O-rings
Polypropylene for high viscosity fluid with enlarged ports, with EPDM O-rings & Hastelloy C valve springs (Only for type 1002, 1006, 1310 & 0814)
NP3
NS3
PS3
TT1
SS1
SS2
SB1
SSM
SBM
Arcylic with PVC check valves & Viton® O-rings
Auto-degassing Arcylic with Viton® O-rings (Only for type 1601, 1201, 0803 & 1002)
Auto-degassing PVC with Viton® O-rings (Only for type 1601, 1201, 0803 & 1002)
Carbon-reinforced PTFE with PTFE O-rings
316 SS with PTFE O-rings (Only for types 0430 & 0260)
316 SS with PTFE O-rings, 1/4" FNPT thread
316 SS with PTFE O-rings, R 1/4" internal thread, R 1/2" for type 0260 (Recommended for combustible media)
pump spare parts &
accessories
motor-driven
metering pumps
solenoid-driven
metering pumps
2505*
2.27 gph, 43.5 psi
NP1
Arcylic with PVC check valves & Viton® O-rings
as SS1, with diaphragm failure indicator, type 2501 only
as SB1, with diaphragm failure indicator, type 2501 only
Valve springs:
0
Without springs
1
With 2 springs, 316 SS, 1.4 psig (0.1 bar)
Electrical connection:
A
230 V 50/60 Hz 1 phase
B
115 V 50/60 Hz 1 phase
D
100 V 50/60 Hz 1 phase
E
500 V 50/60 Hz 1 phase
Control type:
0
Stroke rate adjustment via potentiometer
1
External contact
2
Analog 0-20 mA
3
Analog 4-20 mA
4*
External contact, intrinsically safe [i,a]
*Intrinsically safe only with E=Ex protection
5*
Analog 0-20 mA, intrinsically safe [i,a]
6*
Analog 4-20 mA, intrinsically safe [i,a]
7
Manual with zero volts ON/OFF
8
Manual with zero volts ON/OFF, intrinsically safe [i,a]
Control variant:
0
With potentiometer (Only for control type 0)
1
With momentary contact push-button switch for maximum stroke rate (Not for control type 0)
2
With spring-return change-over switch for maximum frequency rate (not for control type 0)
Approval/Language:
0
BVS - Europe, German, 100 V - 500 V
1
BVS - Europe, English, 100 V - 500 V
2
FM - USA, English, 115 V 230 V
3
CSA - Canada, English, 115 V, 230 V
EXBb
G
1000
PP1
0
A
0
0
0
polymer blending &
dry feed solutions
DULCOTEST®
sensors
DULCOMETER®
instrumentation
0417
0.98 gph, 116 psi
1002
0308
product
overview
0.26 gph, 232 psi
70
01/06/2016 - Extronic
ProMinent® EXtronic®
Solenoid Diaphragm Metering Pumps
Dimensional Drawings
10
20
30
1 0 19
0 9
0
100
70
40 50 60
D
50 4
0
6 (149)
60
G
product
overview
80 70
30 20
10
E
C
Nich t unter
Spannun g
öffnen !
Ø 5,8
solenoid-driven
metering pumps
B
4.9 (125)
5.6 (141)
8.9 (226)
5.7 (144)
12 (306)
A
Pump
B
(136)
(136)
(136)
(136)
(137)
(142)
2.7
2.4
2.0
2.0
1.8
.63
C
(69)
(61)
(52)
(52)
(46)
(16)
ø70
ø85
ø100
ø100
ø135
ø135
6 x 4
8 x 5
8 x 5
12 x 9
DN 10
DN 15
ø38
ø50
ø66
ø66
ø117
ø117
9.0
9.3
9.6
9.6
12.0
12.4
G
(229)
(237)
(244)
(244)
(304)
(314)
1000, 1601, 1201, 0803 1002, 0308, 1006 0613 0814, 0417 0430 0260 PP1
PP1
PP1
PP1
PP1
PP1
15.5
15.5
15.5
15.5
15.0
15.7
(393)
(393)
(393)
(393)
(381)
(398)
5.4
5.4
5.4
5.4
5.4
5.6
(136)
(136)
(136)
(136)
(137)
(142)
2.6
2.6
2.2
2.2
1.8
.63
(67)
(67)
(57)
(57)
(46)
(16)
ø70
ø70
ø90
ø90
ø135
ø135
6 x 4
8 x 5
8 x 5
8 x 5
DN 10
DN 15
ø38
ø50
ø66
ø66
ø117
ø117
9.3
9.3
9.7
9.7
12.0
12.4
(236)
(236)
(246)
(246)
(304)
(314)
1002 1006 1310 1014 PP4
PP4
PP4
PP4
15.3
15.3
15.3
15.3
(389)
(398)
(398)
(398)
5.4
5.7
5.7
5.7
(138)
(145)
(145)
(145)
1.8
3.0
3.0
2.7
(46)
(76)
(76)
(69)
ø85
ø85
ø85
ø100
DN 10
DN 15
DN 15
DN 15
ø50
ø50
ø50
ø66
8.7
8.7
8.7
9.1
(222)
(222)
(222)
(229)
1000, 1601, 1202 0803 1002, 0308, 1006 0613 0814, 0417 0430 0260 TT1
TT1
TT1
TT1
TT1
TT1
TT1
14.9
14.9
15.3
15.3
15.3
15.3
15.7
(378)
(378)
(388)
(388)
(388)
(388)
(398)
5.3
5.3
5.3
5.4
5.4
5.4
5.6
(134)
(134)
(138)
(138)
(138)
(137)
(142)
2.9
2.8
1.3
1.3
1.3
1.4
1.2
(75)
(70)
(32)
(32)
(32)
(35)
(31)
ø60
ø70
ø95
ø95
ø95
ø135
ø135
6 x 4
6 x 4
8 x 5
8 x 5
12 x 9
DN 10
DN 15
ø38
ø38
ø66
ø66
ø66
ø117
ø117
8.8
9.0
10.5
10.5
10.5
10.4
10.6
(223)
(228)
(266)
(266)
(266)
(263)
(268)
1000, 1601, 1202 0803 1002, 0308, 2502/05, 1006 1310, 0613 0814, 0417 0430 0260 SS1
SS1
SS1
SS1
SS1
SS1
SS1
14.8
14.8
15.2
15.2
15.2
15.2
15.4
(376)
(376)
(386)
(386)
(386)
(386)
(390)
5.3
5.3
5.4
5.4
5.4
5.4
5.6
(134)
(134)
(138)
(138)
(138)
(137)
(142)
3.3
3.1
1.9
1.5
1.5
1.4
1.1
(84)
(79)
(48)
(39)
(39)
(35)
(28)
ø60
ø70
ø80
ø95
ø95
ø135
ø135
6 x 5
6 x 5
8 x 7
8 x 7
12 x 10
DN 10
DN 15
ø38
ø38
ø50
ø66
ø66
ø117
ø117
8.4
8.6
9.8
10.2
10.2
10.4
10.7
(214)
(219)
(250)
(259)
(259)
(263)
(271)
1000 1601, 1202, 0803 1002, 0308, 2502/05, 1006 1310, 0613 0814, 0417 0430 0260 SB1
SB1
SB1
SB1
SB1
SB1
SB1
14.7
14.7
15.0
15.0
15.0
15.0
15.1
(373)
(373)
(381)
(381)
(381)
(381)
(383)
5.3
5.3
5.4
5.4
5.4
5.4
5.5
(134)
(134)
(138)
(138)
(138)
(138)
(139)
3.4
3.1
2.2
1.9
1.9
.87
1.1
(87)
(79)
(56)
(48)
(48)
(22)
(27)
ø70
ø85
ø80
ø95
ø95
ø145
ø145
R1/4”
R1/4”
R1/4”
R1/4”
R1/4”
R1/4”
R1/2”
ø38
ø38
ø50
ø66
ø66
ø117
ø117
8.3
8.6
9.5
9.8
9.8
10.8
11.0
(211)
(219)
(242)
(250)
(250)
(275)
(279)
1601, 1202, 0803 1002 NS3
NS3
15.1
15.1
(383)
(383)
5.4
5.4
(136)
(136)
2.6
2.6
(67)
(67)
s. Abb.
s.Abb.
6 x 4
6 x 4
ø38
ø50
9.6
9.6
(243)
(243)
1601, 1202, 0803 1002 NS3
NS3
15.1
15.1
(383)
(383)
5.4
5.4
(136)
(136)
2.6
2.6
(67)
(67)
s. Abb.
s.Abb.
6 x 4
6 x 4
ø38
ø50
9.6
9.6
(243)
(243)
71
polymer blending &
dry feed solutions
5.4
5.4
5.4
5.4
5.4
5.6
DULCOTEST®
sensors
F
(391)
(391)
(391)
(391)
(381)
(398)
01/06/2016 - Extronic
A
DULCOMETER®
instrumentation
E
15.4
15.4
15.4
15.4
15.0
15.7
pump spare parts &
accessories
D
1000, 1601, 1201, 0803 NP1
1002, 0308, 2502/05, 1006 NP1 1310, 0613 NP1
0814, 0417 NP1
0430 NP1
0260 NP1
motor-driven
metering pumps
Dimensions in inches (mm)
ProMinent® EXtronic®
Solenoid Diaphragm Metering Pumps
S p e c i a l Va l v e s f o r E X t r o n i c ®
Rp 1/4
Rp 1/2
Stainless steel 1.4404 “SB” foot valve
With filter and ball check valve, designed for use with flammable materials.
Materials: 1.4404/1.4401/PTFE/ceramic
2.8“
70mm
product
overview
2.1“
54mm
solenoid-driven
metering pumps
809301
Connector ISO 7 Rp 1/2 SB version for ProMinent EXtronic® 924561
Spring loaded ball check valve designed for use with flammable materials.
Materials: 1.4404/1.4401/Hastelloy C/PTFE/ceramic
pk_1_030
pk_1_031
R 1/2
Order No.
Connector ISO 7 Rp 1/4 - R 1/2, pre-pressure approx. 7.3 psi
809302
Connector ISO 7 Rp 1/2 - R 1/2, pre-pressure approx. 7.3 psi
924560
Adjustable “SB” back pressure valve
R 1/2
Materials: 1.4404; PTFE coated diaphragm. Connector both sides ISO 7 Rp 1/4
1.7“
44mm
A
Order No.
Operating range approx. 14.5 - 145 psi (1-10 bar),
closed version designed for use with flammable materials.
924555
To generate a constant back pressure for accurate metering with a free outlet. Can also be
used as an overflow valve.
SW 24
Rp 1/2
PTFE dosing pipe
Rp 1/4
pk_1_032_2
Carbon-filled, surface resistance <107 Ω
pk_1_027
Material Length m Ext. diam. x int. diam.
Rp 1/4
pump spare parts &
accessories
motor-driven
metering pumps
Order No.
Stainless steel 1.4404 “SB” injection valve
SW 32
DULCOMETER®
instrumentation
Connector ISO 7 Rp 1/4 SB version for ProMinent EXtronic® 2.1“ 53mm
pk_1_029
3.1“
79mm
Permissible Order No.
operating
press. psi (bar)*
PTFE Sold by the foot
6.0 x 4.0 174 (12) 1024831
PTFE Sold by the foot
8.0 x 5.0 232 (16) 1024830
PTFE Sold by the foot
12.0 x 9.0 130.5 (9) 1024832
* permissible operating pressure at 68°F (20 °C) in accordance with EN ISO 7751, 1/4 of the
bursting pressure, assuming chemical resistance and correct connection.
Additional ancillary equipment, i.e. foot valves, injection valves and back pressure valves
in the usual material combinations, identical to gamma ancillary equipment and/or for
connector DN 15 Vario ancillary equipment, see section 2.14.
Stainless steel straight threaded connectors
polymer blending &
dry feed solutions
DULCOTEST®
sensors
Swagelok system in stainless steel SS 316 (1.4401) for connection of pipework to liquid
ends and valves with internal thread and for SB version.
Normal thread o-rings compounds required.
Order No.
6 mm - ISO 7 R 1/4
359526
8 mm - ISO 7 R 1/4
359527
pk_1_028
72
01/06/2016 - Extronic
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising