MAKING MODERN LIVING POSSIBLE
UniLynx Inverter Range
Single phase - with transformer - indoor and outdoor cabinets
1.8 – 3.0 – 3.6 – 5.4 kW
SOLAR INVERTERS
The PV system configurator helps users to design and
dimension solar energy systems.
The integrated electromechanical DC switch ensures
maximum security during servicing.
Unique versatility
Three individual PV inputs and three dedicated
MPP trackers form the multi DC string input.
• Multi DC string input
Due to the one to three string input, module mismatch losses and losses from partial shading are greatly reduced; if one string is not functioning optimally, the remaining two strings will continue production unaffected.
• Derating function
Should the inverter come across conditions of increased grid voltage, increased current levels or too high ambient temperatures, it will limit the output accord-
ingly to protect itself. This derating function means that the inverter will continue producing although conditions exceed inverter limitations. This will increase yield while ensuring the inverter is not damaged, and will in the long run ensure
long life.
• One inverter for 16 countries
All Danfoss inverters can run in 16 different countries and are configured on site.
Just select the country at initial set-up and the inverter will configure itself to comply with regulations.
• Individual/parallel configuration and up to 3 MPP trackers
The same inverter can run in both individual and parallel (master/slave) configura-
tion, depending on the configuration of the wiring. If all panels are identical,
master/slave is the ideal configuration. When panels are of varying types, if they have different angles or display different operation conditions, individual
configuration is ideal, as a designated MPP tracker is appointed for each string. The inverter will automatically detect the wiring and run the appropriate configu-
ration via the auto detection algorithm.
• 5 inch or 6 inch modules and thin film
UniLynx comes in two input voltage ranges: High Voltage (HV), dedicated to 5-inch cell modules, and Medium Voltage (MV), dedicated to 6-inch modules. These dedicated input voltage ranges limit power losses and assure the string operating voltage is correct in order for the inverter to optimise total energy output. This transformer inverter also handles thin film modules.
Optimum energy output
• High MPP tracker efficiency
Individual MPP trackers ensure the system always runs at optimum power output regardless of size differences and PV module placement. The accuracy of the MPP trackers has been tested at the Arsenal Research Institute in Vienna as well as in an ISORRIP test, in which representative sample data from a year’s irradiation was used to calculate the efficiency. At static irradiation the MPP tracker efficiency is 99.9% (MPP European Efficiency). And at dynamic irradiation the MPP tracker efficiency is 99.4%.
• Ride Through
All Danfoss inverters have a built-in algorithm called Ride Through. This algorithm ensures the inverter stays on grid even during severe grid disturbances.
The inverters will only disconnect when AC grid limits set by the authorities
are exceeded.
• Early start-up and late stop of daily production
Danfoss Solar Inverters use a combination of two MPP tracking methods,
designed solely to work with both high and low irradiation levels, which ensures power production even with limited sun.
Easy communication and monitoring
Safe and easy to install and service
• RS485 communication
All inverters can be fitted with RS485 cable system data loggers and webloggers for easy communication and monitoring of the investment.
• Standard connection for DC input and AC output
Danfoss inverters cannot be configured wrongly: Just connect the inverter and the auto detection will register the DC-wiring of the inverter and configure
accordingly.
• Integrated DC switch
For the protection of the installation engineer and service personnel, our inverters have an integrated DC switch to enable PV power to be disconnected safely.
Simply switching off the DC switch is enough to disconnect DC power from the solar modules to the inverter.
• Servicing on site
The Unilynx has a modular PCB design. All inverters have one AC PCB and for each string input a dedicated DC PCB. Each individual PCB can be quickly exchanged on site if necessary.
• Service tool
The software-based Service tool makes service extremely easy, allowing techni-
cians to configure and monitor PV inverters and PV inverter networks, as well as updating software via an RS485 standard communication bus.
ULX 1800
ULX 3000
ULX 3600
ULX 5400
Nominal Power DC
Max Power DC
1800 W
1950 W
3000 W
3200 W
3600 W
3900 W
Max recommended PV power at STC 1)
1950 Wp
3200 Wp
3900 Wp
Specification:
Nominal Power AC
Max Power AC
Max efficiency
Euro efficiency
Power factor
Turn on power
Standby consumption
Night consumption
Voltages:
Nominal Voltage DC MV
Nominal Voltage DC HV
MPP voltage range MV - nominal power
MPP voltage range HV - nominal power
MAX DC voltage MV Individual/Parallel
MAX DC voltage HV Individual/Parallel
Turn on voltage DC MV
Turn on voltage DC HV
Turn off voltage DC MV
Turn off voltage DC HV
AC voltage range
Grid frequency
Currents:
Max current DC MV
Max current DC HV
Nominal current AC
Max current AC
Distortion (THD%)
1650 W
2750 W
3300 W
1800 W
93.70 %
91.60 %
0.97 at > 20 % load
20 W
8W
< 0.2 W
3000 W
94.20%
92.90%
0.97 at > 20 % load
20 W
8W
< 0.2 W
3600 W
94.20 %
93.40 %
0.97 at > 20 % load
20 W
8W
< 0.2 W
5400 W
5850 W
Outdoor: 5400/5850 Wp
Indoor: 5400 Wp
Outdoor: 4600/5000 W
Indoor: 4600 W 2)
5000/5400 W 2)
94.30 %
93.40 %
0.97 at > 20 % load
20 W
8W
< 0.2 W
310 V
430 V
180-350 V
260-500 V
450/410 V
600/550 V
125 V
250 V
100 V
200 V
230 ± 15% V
50 ± 5 Hz
310 V
430 V
180-350 V
260-500 V
450/410 V
600/550 V
125 V
250 V
100 V
200 V
230 ± 15% V
50 ± 5 Hz
310 V
430 V
180-350 V
260-500 V
450/410 V
600/550 V
125 V
250 V
100 V
200 V
230 ± 15 % V
50 ± 5 Hz
310 V
430 V
180-350 V
260-500 V
450/410 V
600/550 V
125 V
250 V
100 V
200 V
230 ± 15 % V
50 ± 5 Hz
10 A
7A
7.2 A
8A
<5%
2 x 10 (20) A*
2x7 (14) A
12 A
13 A
<5%
2 x 10 (20) A*
2x7 (14) A
14.5 A
15.5 A
<5%
3x10 (30) A*
3x7 (21) A*
Outdoor: 20/22 A / Indoor: 20 A
23 A
<5%
Other:
Dimensions (L,W,H)
Weight
Acoustic Noise level
Operation temperature range
MPP Tracker
MPP efficiency (static)
Overload operation
Grid surveillance
Mounting recommandation
IP
Isolation monitoring
Galvanic Isolation
Serial Communication
Display
DC switch
Parallel string operation
Normative references:
Directive LVD
Directive EMC
Safety
EMC immunity
EMC emission
Utility Interference
Functional safety, Anti-islanding
CE
Utility characteristics
Italy
Spain
Outdoor: 489x434x192 mm /
Outdoor: 618x434x192 mm /
Outdoor: 618x434x192 mm /
Outdoor: 747x434x192 mm /
Indoor: 369x386x188 mm
Indoor: 498x386x188 mm
Indoor: 498x386x188 mm
Indoor: 631x386x188 mm
Outdoor: 17 kg / Indoor: 14 kg
Outdoor: 20 kg / Indoor: 20 kg
Outdoor: 20 kg / Indoor: 20 kg
Outdoor: 23 kg / Indoor: 23 kg
Outdoor: 55 dB(A) / Indoor: 45 dB(A)
Outdoor: 55 dB(A) / Indoor: 45 dB(A)
Outdoor: 55 dB(A) / Indoor: 45 dB(A)
Outdoor: 55 dB(A) / Indoor: 45 dB(A)
-25 - - +60 °C
-25- - +60 °C
-25- - +60 °C
-25 - - +60 °C
1
2
2
3
99.9 %
99.9 %
99.9 %
99.9 %
Change of operating point
Change of operating point
Change of operating point
Change of operating point
U/f window & impedance monitoring U/f window & impedance monitoring U/f window & impedance monitoring U/f window & impedance monitoring
Wall bracket
Wall bracket
Wall bracket
Wall bracket
IP 21/ IP 54
IP 21/ IP 54
IP 21/ IP 54
IP 21/ IP 54
included
included
included
included
Transformer
Transformer
Transformer
Transformer
RS485
RS485
RS485
RS485
Display
Display
Display
Display
DC switch
DC switch
DC switch
DC switch
Parallel string operation /Autodetection Parallel string operation /Autodetection Parallel string operation /Autodetection Parallel string operation /Autodetection
73 / 23 / EC
2004 / 108 / EC
EN 50178
EN 61000-6-1
EN 61000-6-2
EN 61000-4-13, -14, -28
EN 60146-1
EN 61000-6-3
EN 61000-6-4
EN 61000-3-2, -3
DIN VDE 0126-1-1
Yes
IEC 61727, EN 50160
DK5940
RD1663
Per October 2009
*Max. 16 A per string
1) For fixed systems with semi optimal conditions
2) Depending on country setting
73 / 23 / EC
2004 / 108 / EC
EN 50178
EN 61000-6-1
EN 61000-6-2
EN 61000-4-13, -14, -28
EN 60146-1
EN 61000-6-3
EN 61000-6-4
EN 61000-3-2, -3
DIN VDE 0126-1-1
Yes
IEC 61727, EN 50160
DK5940
RD1663
73 / 23 / EC
2004 / 108 / EC
EN 50178
EN 61000-6-1
EN 61000-6-2
EN 61000-4-13, -14, -28
EN 60146-1
EN 61000-6-3
EN 61000-6-4
EN 61000-3-2, -3
DIN VDE 0126-1-1
Yes
IEC 61727, EN 50160
DK5940
RD1663
73 / 23 / EC
2004 / 108 / EC
EN 50178
EN 61000-6-1
EN 61000-6-2
EN 61000-4-13, -14, -28
EN 60146-1
EN 61000-6-3
EN 61000-6-4
EN 61000-3-11, -12
DIN VDE 0126-1-1
Yes
IEC 61727, EN 50160
DK5940
RD1663
Danfoss Solar Inverters A/S
Jyllandsgade 28
DK-6400 Sønderborg
Denmark
Tel: +45 7488 1300
Fax: +45 7488 1301
E-mail: solar-inverters@danfoss.com
www.solar-inverters.danfoss.com
Produced by Danfoss A/S © (GS Advertising) October 2009