Powermatic_User_Manual
®
HOLES FOR
ALLEN KEY
BODY
LINK ROD
LOCKING SCREW
CLOSING
SPEED
ADJUSTER
WITH
DUST CAP
POWER
LATCHING
ACTION
ADJUSTER
LINK ROD
HOLES FOR
ALLEN KEY
FRAME
PLATE
DOOR PLATE
IMPORTANT NOTICE - FOR FIRE DOOR INSTALLATIONS
REFER TO ITEM 1 IN FITTING INSTRUCTIONS
• CE marked and adjustable to conform to power size 3 of Controlled
Door Closing Device. BS EN1154: 1997 (Test door 60kg).
• 1/ 2 Hour Fire Test BS EN1634-1: 2000.
• Adjustable speed control.
• Adjustable power latching action.
• 1 1/2 pairs of hinges should be used in conjunction with this
closer on all doors.
• Suitable for doors opening to a maximum of 105º. A door stop should be fitted.
• Maximum door weight 80kg, width 950mm.
• Suitable for latched and unlatched doors.
• Should NOT be used with rising butt hinges or concealed mortice hinges.
PLEASE READ FITTING INSTRUCTIONS THOROUGHLY
BEFORE INSTALLATION.
®
PARTS LIST
(A)
(B)
(C)
Door Closer - x 1
Template - x 1
Allen Keys - x 2
(D)
Speed Adjustment
Tool - x 1
(E)
(F)
Screws - x 12 Extractor Bolt - x 1
(G)
Allen
Key for
Adjuster Screw
(Locking) x 1
CHECK ALL COMPONENT PARTS AGAINST PARTS LIST.
TOOLS REQUIRED
• Screwdriver (Plain Slotted)
• Screwdriver (Pozi-Drive)
• Wood Chisel 25mm x 185mm
• Solid Centre Auger Bit or Spade
Bits 26mm Ø & 28mm Ø
• Bradawl
The use of a Souber morticer
is suggested for multiple on
site installations.
(Available from Souber Tools)
soubertools.com
Eye Protectors,
• Power Drill
Ear Defenders
• Tape Measure
and a Face Mask are
• Pencil
recommended during
• Adjustable Spanner
installation of
• Ruler
Perko-Powermatic.®
1
IMPORTANT NOTICE
DOOR CLOSERS FITTED
TO A FIRE DOOR.
• Perko Powermatic,® conforms to
Power Size 3 of Controlled Door
Closing Device Standard BS
EN1154:1997 when the power
latching action is set to
maximum.
• Turn adjuster screw fully to
positive (+) as explained in 9.
• Closer must be fitted no more
than 750mm from floor and
within 300mm of a hinge.
• Closer and plates should be
bedded in Alfacryl FR Intumescent
Acrylic Mastic available from
Samuel Heath.
2
TEMPLATE POSITIONING
• Ensure door is plumb, hinges are
free, and that timber is sound.
• Take template provided and
fold along centre line. Open door
to maximum of 105º.
• Secure template to door edge
and frame edge within 300mm of
a hinge ensuring the centre line is
central in the gap between door
and frame.
• Draw a vertical line at the
centre point of the door edge on
the template.
NB This line must not exceed
35mm from template centre line.
• Repeat on frame edge.
• The maximum distance
between these 2 vertical lines
must not exceed 52mm when
door is opened to its maximum
of 105º.
• At each point on the
template where the vertical
lines cross the horizontal
dotted lines mark through the
template using a bradawl into
the door edge and frame edge
to establish drilling points.
Remove template RETAIN FOR
REFERENCE.
• Note: Door can now be
removed from frame to assist
drilling if preferred.
3
FRAME PREPARATION FOR
FRAME PLATE
4
DOOR PREPARATION FOR
BODY & DOOR PLATE
NB To ensure correct operation
of closer there must be a 3mm
gap between the two fixing
plates when the door is in the
closed position.
• Drill 4 x 28mm Ø holes 30mm
• Drill 4 x 26mm Ø x 185mm
deep to accept frame plate
deep holes to accept closer
assembly as indicated on
body as indicated on the
template.
template.
• Drill 2 x 28mm Ø holes to
• Drill 2 x 28mm Ø holes to
accept frame plate ends. Depth
accept door plate ends. Depth
must cater for 3mm gap
must cater for 3mm gap
between plates when fitted.
between plates when fitted.
• Remove excess timber
• Remove excess timber
between drilled holes to
between drilled holes to accept
accommodate frame plate.
the closer body and door plate.
5
INSTALLING CLOSER
6
• Insert the allen keys (C)
through both top and bottom
• Insert closer body into door.
link rod holes.
• Insert extractor bolt (F) into
Both allen keys must be
position and rotate clockwise
correctly located.
until holes in link rods appear.
• Remove extractor bolt.
• Generally for thicker doors
• Secure door plate to door
expose both holes on each rod.
with six screws (E).
7
8
ADJUSTMENT
- CLOSING SPEED
• With closer now held open by
allen keys, if necessary firmly
push both link rods across door
• Remove dust cap.
plate and offer frame plate
• use adjuster tool (D)
into frame void. Secure with six
• Positive (+) increases door
screws (E).
speed.
• Open door slightly and
Negative (-) reduces door
remove allen keys.
speed, as indicated on door
• Installation is now complete.
plate.
9
ADJUSTMENT
- POWER LATCHING ACTION
• The power latching action
can be adjusted using a plain
slotted screwdriver.
• Loosen locking screw using
allen key (G) to allow the
adjuster screw to turn.
• Positive (+) increases the
angle at which latching action
engages.
Negative (-) decreases angle at
which the latching action
engages.
• Re-tighten locking screw
when correct power latching
action achieved.
The Perko Powermatic ® is protected by the following Patents and
Applications.
CANADA
2365822
2436363
HONG KONG
1038953
JAPAN
2000-602490
SINGAPORE
82862
TAIWAN
156554
USA
6625847
2004/0111831
UK
1159503
02740038.1
0413132.2
AUSTRIA
1159503
02740038.1
BELGIUM
1159503
02740038.1
DENMARK
1159503
02740038.1
FRANCE
1159503
02740038.1
GERMANY
1159503
02740038.1
IRELAND
1159503
02740038.1
ITALY
1159503
02740038.1
LUXEMBOURG
02740038.1
NETHERLANDS
1159503
02740038.1
SPAIN
1159503
02740038.1
SWEDEN
1159503
02740038.1
SWITZERLAND
1159503
02740038.1
LIECHTENSTEIN
02740038.1
Leopold Street, Birmingham B12 0UJ, England
Telephone: 0121 772 2303 Fax: 0121 772 3334
Sales Office Direct Line: 0121 766 4200
International Telephone: +44 121 772 2303 International Fax: +44 121 772 3334
e-mail: info@samuel-heath.com
www.samuel-heath.com
e-mail: powermatic@samuel-heath.com
www.perko-powermatic.com
9- 395 10/04 10K