WAVERUNNER ® 6000A SERIES
The New Benchmark for
Everyday Oscilloscopes
The WaveRunner 6000A Series
The Everyday Bench Oscilloscope
The WaveRunner ® 6000A Series is the best oscilloscope for
everyday signal testing. Its remarkable functionality includes
the following capabilities:
– acquisition technology that delivers measurements you can trust
– an efficient interface that feels just right to the busy engineer
– uncommon capabilities—right out of the box
– a platform for building on even more functionality
A Rich Feature Set is Standard
Outstanding Signal Fidelity
This outstanding performance gives
The WaveRunner 6000A Series is
The WaveRunner 6000A Series
you timing resolution that rivals
an everyday bench scope with true
is powered by the same SiGe
oscilloscopes that cost twice as much.
“lab instrument” capabilities. This
chipset that is used in LeCroy’s
series offers:
higher bandwidth WaveMaster
Windows® XP
Operating System
• Bandwidths from 350 MHz to 2 GHz
oscilloscopes.
The open Windows XP operating
• Sample rates of 2.5 to 10 GS/s
• High sample rate captures
system allows you to install Windows
high frequency transients
application software to analyze wave-
and sharp edges
form data directly in the oscilloscope,
• Standard memory of 4 Mpts/Ch
• All channels expandable to 12 Mpts
• Up to 24 Mpts when interleaved
Most importantly, these features are
delivered at a price far below other
oscilloscopes in this class.
2
• Very low residual jitter (2 ps typical)
• Includes ultra-stable clock (±5 ppm)
eliminating the need for processing
in another PC.
5 GS/s on Each Channel—
See Details Others Miss
The WaveRunner 6000A is a true
4 channel instrument — you can
sample at a full 5 GS/s on each
channel. Other oscilloscopes can only
use a single channel at 5 GS/s or 1/4
that rate when using all four channels.
WaveRunner 6000A offers more than
Nyquist sample rate on each channel.
SMART Trigger™ Makes the
Most of Your Long Memory
With a true 5 GS/s on each channel, this
300 MHz square wave (checking a timing
delay problem between multiple clock
signals) is displayed accurately.
• Exclusion/inclusion feature triggers
Other oscilloscopes are limited to 1.25 GS/s
on each channel and display the same
measurement as a less than informative
sinusoidal signal.
• Memory retains thousands of
on signals outside, or within, a
acquired events for viewing at
The WaveRunner 6000A SMART Trigger
specific range of pulse widths.
your leisure.
provides the flexibility to quickly trigger
• Selecting multiple threshold levels
and locate the specific signal charac-
and pulse widths quickly catches the
teristic or pattern you want. Trigger on
waveform for viewing and measuring.
• Replay signal history, scan, and
search from sweep to sweep.
abnormal signals at the touch of a button.
3
The WaveRunner 6000A Series
An Outstanding Scope Experience
The WaveRunner 6000A oscilloscope
is designed to be a custom fit to your
working style. Hundreds of oscilloscope
users helped us meet this goal by
contributing their ideas to the
uniquely efficient interface.
1. Bright Display
All WaveRunner 6000A Series oscilloscopes include a crisp and bright SVGA
screen with 800 x 600 pixels for superior
resolution. It’s the best resolution
available for this class of scope.
1
4
2. One-touch Efficiency
The descriptor labels show the
oscilloscope settings and status.
Touch the screen once to open a
setup dialog and change settings.
Quickly measure a signal’s timing
characteristics. Touch “Measure” and
“Horizontal” to see multiple common
timing parameters. Math, histograms,
statistics, and other analysis tools
are all within two touches.
3. Dedicated Vertical Controls
Each channel has its own volts per
division (V/div) control knob. You can
control any channel by turning the
knob—eliminating the need to
multiplex a single V/div control across
all four channels.
4. Intensity Modulated Display
Display intensity can be adjusted
from 0–100% to enable a better
view of underlying glitches, runts,
or signal modulation in long record
captures. The perfect accompaniment
to the WaveRunner 6000A oscilloscope’s
long memory.
4
2
PP007 Passive Probe
Only 2.5 mm in diameter
with low circuit loading and
a flat impulse response,
this probe is the ideal fit for
general-purpose applications.
5. Cursor Knobs
Need a quick measurement? Just
turn the cursor knob to bring up a pair
of vertical cursors to measure timing
relationships and quickly characterize
the waveform.
7
6. Zoom Control Knobs
Need a closer look at your signal?
Push the QuickZoom button. Four
dedicated knobs (zoom and offset in
horizontal and vertical directions) make
it easy to navigate any trace—from
broad relationships to minute details.
3
7. “Push” Knobs
5
6
8
WaveRunner rotating knobs control
functions, but pushing them invokes
further functionality. Push the trigger
level; the scope selects the correct
setting for a stable display. Push the
offset button; your scope instantly
zeroes the offset, restoring the
waveform clearly in the middle of
the screen. Another push restores
the offset.
8. Handy, Front Accessible
USB Port
Use a memory stick to transfer your
captured waveforms, or take your setup
from scope to scope to automatically
load your configuration. In addition,
with one USB port on the front panel
and four more on the back, you can
connect a variety of plug-n-play
peripheral and memory devices.
5
LabNotebook™
An In-Scope Solution for Documenting Results
WaveRunner lets you focus on understanding your signal rather
than setting up your oscilloscope. The productivity improvement
is dramatic and immediate. Here’s a prime example of how
thoroughly WaveRunner fits your everyday process.
LeCroy Introduces a Complete
In-scope Solution—Standard
on most LeCroy Oscilloscopes
Now you can efficiently create
complete and detailed waveform
reports directly in the oscilloscope.
An all-in-one solution for annotating
and sharing information, LabNotebook™
simplifies results recording and report
generation by eliminating the multi-step
processes that often involve several
LabNotebook enables you to focus
on results rather than the process, so
you can now:
• Save all displayed waveforms
• Save the relevant setups with the
saved waveform
• Add freehand notes with a stylus
or as text
• Convert the complete report to pdf,
rtf, or html
• Print or e-mail reports
pieces of equipment.
Create Notes with the
Screen Capture
By pressing Hard Copy, you can
annotate waveforms as you
Flashback Function
capture them. Once the notes
You can employ the Flashback Function
are finished, they can be readily
to recall the state of the oscilloscope,
saved as a report and e-mailed
including saved waveforms and setup.
directly from the oscilloscope.
Additional measurements are easily
made using the keyword filter to find
the correct notebook entry for recall.
6
From Everyday Testing
to Robust Analysis
It’s the perfect end-to-end solution: a bench top oscilloscope
that can handle everyday signal measurements easily and
efficiently, but can expand to perform more sophisticated
WaveShape Analysis when needed. Yet it’s priced far below
other scopes that are not nearly as versatile and fully featured.
Expanded Analysis
XDEV seamlessly integrates your
the oscilloscope’s interface. This
The XMATH Advanced Math software
custom measurements directly into
package utilizes the power and
package provides more than 30 math
the oscilloscope’s data path, eliminating
efficiency of customization to
functions and 40 parameter measure-
the need to run separate programs. You
enable faster analysis and solutions
ments including:
can also use XDEV to customize
for your specific tasks.
• Parameter math
• Tracking measurements
Software Option Packages
• Expanded FFT (up to 24 Mpts)
General Purpose
• Expanded histogramming
• Trending of up to one million events
Master Analysis Software Package (Includes JTA2, XMATH and XDEV)
WR6-XMAP
Advanced Math Software Package
WR6-XMATH
Customization Software Package
WR6-XDEV
XMATH has a graphical interface
Value Analysis Software Package (Includes XWAV and JTA2)
WR6-XVAP
that lets you connect input source,
Intermediate Math Software Package
WR6-XWAV
measurement, and display icons for
Processing Web Editor Software Package for Functions and Parameters
WR6-XWEB
surprisingly simple advanced analysis.
Application Specific
Custom Analysis
Jitter and Timing Analysis Software Package
WR6-JTA2
PowerMeasure Analysis Software Package
WR6-PMA2
Digital Filter Software Package
WR6-DFP2
software package allows you to create
EMC Pulse Parameters Software Package
WR6-EMC*
your own scripts for measurement
Disk Drive Measurement Software Package
WR6-DDM2
parameters or math functions, using
Ethernet Test Software Package (WaveRunner 6200A Only)
WR6-ENET
third-party software packages such as
USB 2.0 Compliance Test Software Package (WaveRunner 6200A Only)
WR6-USB2
WR6-SDM†
The XDEV Advanced Customization
Excel, MATLAB, and Mathcad.
Serial Data Mask Software Package
Software and Hardware Option Packages
32 Digital Channel Oscilloscope Mixed Signal Option
CANbus TDM Trigger, Decode and Measure/Graph Testing Option
MS-32‡
CANbus TDM
CANbus TD Trigger and Decode Testing Option
CANbus TD
* WR6-EMC is compatible with all WaveRunner 6000A oscilloscopes except the WR6030A model.
†WR6200A oscilloscope required for full mask testing capability; lower bandwidth models will have
reduced capabilities.
‡MS-32 is compatible only with WR6000A 4-channel oscilloscopes.
7
Expandability Ensures an
Excellent Return on Investment
Mixed Signal Testing
Oscilloscope Option (MS-32)*
Add 32 digital channels to a 4-channel
oscilloscope for 4 analog + 32 digital
testing capability, with a simple
oscilloscope setup and user interface.
Each digital channel has 1 Mpts/Ch
(32 Mpts total!) to capture all of your
signal information for efficient debug
and analysis. 32 digital channels is
ideal for the most efficient testing of
16-bit embedded controllers where
all 16 ADDR and DATA lines can be
viewed simultaneously.
*MS-32 is compatible only with WR6000A
4-channel oscilloscopes.
CANbus Trigger, Decode,
and Measure/Graph Testing
Options (CANbus TDM,
CANbus TD)
Flexibly trigger on CAN bus messages.
Decode and display hexadecimal data
values next to the CAN signal on the
screen. Measure and statistically
analyze timing and other data. Graph
system performance. Easily correlate
electrical problems to CAN bus
messages or error frame data.
Jitter and Timing Analysis
Software Package (JTA2)
Find modulation effects and intermittent
signal jitter to track timing changes,
and to debug in the time, frequency,
and statistical domains. Views like Jitter
Track and Jitter Histogram let you see
system variability in ways that you have
never imagined.
Digital Filter Software Package
(DFP2)
8
DFP2 lets you add any of a set of
linear-phase Finite Impulse Response
(FIR) filters. It enhances your ability to
examine important signal components
by filtering out undesired spectral
components such as noise. Use the
standard filters or create your own.
Electromagnetic
Compatibility Software
Package (EMC)*
The EMC software package
adds flexibility to the rise time,
fall time, and width parameters
that are necessary to accurately
measure ESD pulses, EFT bursts,
surges and transients that are
common in EMC testing. The
WaveRunner 6000A provides
easy access to parameter statistics
and, with the EMC package,
allows histogramming up to 2 billion
events, parameter math, and
measurement filtering.
*WR6-EMC is compatible with all WaveRunner 6000A
oscilloscopes except the WR6030A model.
Disk Drive Measurement
Software Package (DDM2)
The Disk Drive Measurement Package
(DDM2) adds dozens of new disk drive
measurements. DDM2, combined
with WaveRunner 6000A’s sequence
triggering and SMART Triggers, offers
the perfect solution for failure analysis
when testing disk drives.
PowerMeasure Analysis
Software Package (PMA2)
The PMA2 package automates and
enhances your ability to analyze
power conversion devices and
circuits. Optional accessories, such
as differential amplifiers, differential
probes, current probes, and deskew
fixtures complete the solution.
USB 2.0 Compliance Test
Software Package (USB2)
(WaveRunner 6200A Only)
USB2 provides a complete acquisition
and analysis system for USB 2.0
devices, hosts, and hubs, as specified
in the USB-IF USB 2.0 Electrical Test
Specification, version 1.0.
Ethernet Test Software
Package (ENET)
(WaveRunner 6200A Only)
Conduct complete electrical testing
for 1000Base-T, 100Base-T, and
10Base-T Ethernet standards. Jitter
and pulse mask tests are performed
with automatic waveform alignment,
and all test results feature pass/fail
indicators corresponding to the
IEEE 802.3-2000 and ANSI X3.263
standards being tested.
Serial Data Mask Software
Package (SDM)*
The SDM toolset harnesses the
WaveRunner 6000A Series ocilloscope’s
long memory and low jitter to deliver
outstanding serial bus characterization.
Choose from a comprehensive list
of standard eye pattern masks, or
create a user-defined mask. Mask
violations are clearly marked on the
display, so you don’t have to guess.
SDM also allows a software“GOLDEN”
PLL reference to recover an eye
diagram from a single long acquisition.
The measurement is complete in
seconds, and the already low trigger
jitter is eliminated, giving you the
most precise result possible.
*WR6200A oscilloscope required for full mask
testing capability; lower bandwidth models will
have reduced capabilities.
Application and Analysis Package Specifications
Standard
Software Options
Advanced Math and WaveShape Analysis
Math Tools
Display up to four math function traces (F1–F4). The easy-to-use graphical
interface simplifies setup of up to two operations on each function trace,
and function traces can be chained together to perform math-on-math.
absolute value
average (summed)
average (continuous)
custom (MATLAB, Mathcad,
VBScript) – limited points
derivative
deskew (resample)
difference (–)
enhanced resolution (to 11 bits vertical)
envelope
exp (base e)
exp (base 10)
fft (power spectrum, magnitude, phase,
up to 50 kpts)
floor
histogram of 1000 events
integral
invert (negate)
log (base e)
log (base 10)
product (x)
ratio (/)
reciprocal
rescale (with units)
roof
(sinx)/x
square
square root
sum (+)
trend (datalog) of
1000 events
zoom (identity)
Master Analysis Software Package (XMAP)
This package provides maximum capability and flexibility, and includes all the
functionality present in XMATH, XDEV, and JTA2
Advanced Math Software Package (XMATH)
This package provides a comprehensive set of WaveShape Analysis
tools providing insight into the wave shape of complex signals.
Additional capability provided by XMATH includes:
• Parameter math – add, subtract, multiply, or divide two different parameters.
Invert a parameter and rescale parameter values.
• Histograms expanded with 19 histogram parameters and up to
2 billion events
• Trend (datalog) of up to 1 million events
• Track graphs of any measurement parameter
• FFT capability added to include: power averaging, power density, real
and imaginary components, frequency domain parameters, and FFT
on up to 24 Mpts.
• Persistence histogram
• Persistence trace (mean, sigma, range)
• Narrow-band power measurements
• Auto-correlation function
• Sparse function
• Cubic Interpolation function
Measure Tools
Advanced Customization Software Package (XDEV)
Display any 6 parameters together with statistics, including their average,
high, low, and standard deviations. Histicons provide a fast, dynamic view
of parameters and wave shape characteristics.
This package provides a set of tools to modify the scope and customize it
to meet your unique needs. Additional capability provided by XDEV includes:
amplitude
area
base
cycles
custom (MATLAB,
Mathcad, VBScript)
- limited points
delay
∆ delay
duration
duty cycle
falltime (90–10%,
80–20%, @ level)
first
frequency
last
level @ x
maximum
mean
median
minimum
number of points
+overshoot
–overshoot
peak-to-peak
period
phase
risetime (10–90%,
20–80%, @ level)
rms
std. deviation
time @ level
top
∆ time @ level
∆ time @ level from
trigger
width (positive +
negative)
x@ max.
x@ min.
Pass/Fail Testing
Simultaneously test multiple parameters against selectable parameter limits
or pre-defined masks. Pass or fail conditions can initiate actions including
document to local or networked files, e-mail the image of the failure, save
waveforms, send a pulse out at the rear panel auxiliary BNC output, or
(with the GPIB option) send a GPIB SRQ.
• Creation of your own measurement parameter or math function, using
third-party software packages, and display the result in the scope.
Supported third-party software packages include:
– VBScript – MATLAB – Excel – Mathcad
• CustomDSO – create your own user interface in a scope dialog box.
• Addition of macro keys to run VBScript files
• Support for plug-ins
Value Analysis Software Package (XVAP)
XVAP Adds the following capabilities:
Measurements:
• Jitter and Timing parameters (period@level,width@level, edge@level,
duty@level, time interval error@level, frequencey@level, half period,
setup, skew, ∆ period@level, ∆ width@level).
Math:
• Persistence histogram • Persistence trace (mean, sigma, range)
• 1 Mpts FFTs with power spectrum density, power averaging, real,
imaginary, and real+imaginary settings)
Statistical and Graphical Analysis:
• 1 Mpts Trends and Histograms • 19 histogram parameters
• Track graphs of any measurement parameter
Intermediate Math Software Package (XWAV)
XWAV Adds the following capabilities:
Math:
• 1 Mpts FFTs with power spectrum density, power averaging,
real, and imaginary components
Statistical and Graphical Analysis:
• 1 Mpts Trends and Histograms
• 19 histogram parameters
• Track graphs of any measurement parameter
9
Application and Analysis Package Specifications
Application Specific Test and Analysis Packages
Disk Drive Measurements Package (DDM2)
Jitter and Timing Analysis Software Package (JTA2)
This package provides disk drive parameter measurements and related
mathematical functions for performing disk drive WaveShape Analysis.
This package provides jitter timing and analysis using time, frequency,
and statistical views for common timing parameters, and also includes
other useful tools. JTA2 includes:
• Jitter and timing parameters, with “Track” graphs of
– Cycle-Cycle Jitter
– N-Cycle
– N-Cycle with start
selection
– Frequency
– Period
– Half Period
– Width
– Time Interval Error
– Setup
– Hold
– Skew
– Duty Cycle
– Duty Cycle Error
• Edge@lv parameter (counts edges)
• Histograms expanded with 19 histogram parameters
and up to 2 billion events
• Trend (datalog) of up to 1 million events
• Track graphs of all parameters
• Persistence histogram, persistence trace (mean, range, sigma)
Digital Filter Software Package (DFP2)
LeCroy’s Digital Filter Package (DFP2) implements a set of linear-phase
Finite Impulse Response (FIR) filters and IIR filters. It enhances your
ability to examine important signal components by filtering out undesired
spectral components such as noise. With the custom design feature,
corrupted signals can be reconstructed by applying matched (mirror)
filters to compensate for known distortions.
The DFP2 option has a broad range of applications:
– System Identification
– Prediction
– Noise Cancellation
– Low-pass Filters
– Band-stop Filters
– Band-pass Filters
– High-pass Filters
– Raised Cosine, Raised Root Cosine, and Gaussian Filters
PowerMeasure Analysis Package (PMA2)
This package provides exceptional ability to measure and analyze the
operating characteristics of power conversion devices and circuits.
– Automatic setup and display of relevant waveforms and parameters
• Disk Drive Parameters are as follows:
amplitude assymetry
local base
local baseline separation
local maximum
local minimum
local number
local peak-peak
local time between events
local time between peaks
local time between troughs
local time at minimum
local time at maximum
local time peak-trough
local time over threshold
local time trough-peak
local time under threshold
narrow band phase
narrow band power
overwrite
pulse width 50
pulse width 50pulse width 50+
resolution
track average amplitude
track average amplitudetrack average amplitude+
auto-correlation s/n
non-linear transition shift
• Correlation function
• Trend (datalog) of up to 1 million events
• Histograms expanded with 18 histograms parameters
and up to 2 billion events
CANbus TDM Trigger, Decode, and Measure/Graph Testing Option
(CANbus TDM)
• Trigger Module with TC251-OPTO optically isolated Trigger Coupler
installed (and room for one additional Trigger Coupler). Trigger Couplers
are interchangeable.
• CANbus TD Series Oscilloscope Interface Module with 1.0 meter
connection cable. Connects Trigger Module to LeCroy oscilloscope
ProBus interface.
• Storage case with accessories (other accessories may be required)
• Software for
– Trigger Setup
– CAN Protocol Decode
– CAN Measurement, (CAN-analog, CAN-CAN, and Time@CAN timing
parameters, CAN bus load% and CAN-Value Data Extraction parameters)
– Histogramming (up to 2 billion events)
– Graphing (Track and Trend).
CANbus TD Trigger and Decode Testing Option (CANbus TD)
– Waveforms scaled and displayed in volts, amps, watts, ohms, etc.
• Same hardware package as CANbus TDM
– Power device performance analyzed in-circuit
• Software for only
– Trigger Setup
– CAN Protocol Decode
– Measure and view time domain response of the entire control loop
– Pre-compliance line harmonic testing to EN 61000-3-2
– Complete solutions available including probes and differential amplifiers
EMC Pulse Parameter Software Package (WR6-EMC)*
This package includes enhanced Rise@level, Fall@level and Width@level
parameters. The new functionality in the WR6-EMC software package
includes user definable thresholds for accurate pulse measurements.
*WR6-EMC is compatible with all WaveRunner 6000A oscilloscopes
except the WR6030A.
10
Oscilloscope Mixed Signal Option (MS-32)*
32 Digital Channel Oscilloscope Mixed Signal Option.
Gripper probe accessories are recommended.
*MS-32 is compatible only with WR6000A 4-channel oscilloscopes.
Specifications
Vertical System
Nominal Analog Bandwidth @ 50 Ω,
10 mV-1 V/div
Rise Time (Typical)
Input Channels
Bandwidth Limiters
Input Impedance
Input Coupling
Maximum Input Voltage
Channel to Channel Isolation
Vertical Resolution
Sensitivity
DC Accuracy
Offset Range
Offset Accuracy
Input Connector
WaveRunner
6030A
WaveRunner
6050A
WaveRunner
6051A
WaveRunner
6100A
WaveRunner
6200A
350 MHz
500 MHz
500 MHz
1 GHz
2 GHz
1 ns
4
750 ps
4
750 ps
2
300 ps
4
200 ps
4
20 MHz; 200 MHz
1 MΩ || 20 pF (10 MΩ || 9.5 pF using PP007 probe)
50 Ω: DC, 1MΩ: AC, DC, GND
50 Ω: 5 Vrms, 1 MΩ: 250 V max. (Peak AC: ≤ 10 kHz + DC)
> 40 dB @ < 100 MHz (> 30 dB @ full bandwidth)
8 bits; up to 11 with enhanced resolution (ERES)
50 Ω: 2 mV/div–1 V/div fully variable; 1 MΩ: 2 mV–10 V/div fully variable
±1.0% of full scale (typical); ±1.5% of full scale, ≥ 10 mV/div (warranted)
50 Ω: ±400 mV @ 2–4.95 mV/div
±1 V @ 5–100 mV/div
±10 V @ 102 mV/div–1 V/div
1 MΩ: ±400 mV @ 2–4.95 mV/div
±1 V @ 5–100 mV/div
±10 V @ 102 mV/div–1 V/div
±100 V @ 1.02 V/div–10 V/div
±(1.5% of offset value + 0.5% of full scale +1 mV) all fixed gain setting < 2 V/div
±(1.5% of offset value + 1.0% of full scale + 1 mV) for variable and V/div settings ≥ 2 V/div
ProBus/BNC
Timebase System
Timebases
Time/Division Range
Clock Accuracy
Sample Rate and Delay Time Accuracy
Trigger and Interpolator Jitter
Time Interval Accuracy
Channel to Channel Deskew Range
External Sample Clock
Roll Mode
Internal timebase common to all input channels; an external clock may be applied at the auxiliary input
Real time: 200 ps/div – 10 s/div, RIS mode: to 20 ps/div, Roll mode: up to 1,000 s/div
≤ 5 ppm @ 25 °C (≤ 10 ppm @ 5–40 °C)
Equal to Clock Accuracy
≤ 3 ps rms (typical)
Clock Accuracy + Jitter
±9 x time/div setting, 100 ms max., each channel
DC to 1 GHz; 50 Ω, (limited BW in 1 MΩ), BNC input, limited to 2 Ch operation (1 Ch in WR6051A),
(minimum rise time and amplitude requirements apply at low frequencies)
User selectable. Available at lower time/div settings
Acquisition System
Single-Shot Sample Rate/Ch
Interleaved Sample Rate (2 Ch)
Random Interleaved Sampling (RIS)
Trigger Rate
Sequence Time Stamp Resolution
Minimum Time Between
Sequential Segments
Acquisition Memory Options
Standard
Option L
Option VL
Acquisition Processing
Time Resolution (min, Single-shot)
Averaging
ERES
Envelope (Extrema)
Interpolation
2.5 GS/s
5 GS/s
5 GS/s
N/A
5 GS/s
N/A
5 GS/s
10 GS/s
5 GS/s
10 GS/s
200 GS/s
125,000 waveforms/second
1 ns
8 µs
Max. Acquisition Points (4 Ch/2 Ch, 2 Ch/1 Ch in WR6051A)
4M/8M
8M/16M
12M/24M
WR6030A
WR6050A
WR6051A
200 ps (5 GS/s)
Segments (Sequence Mode)
1,000
5,000
10,000
WR6100A
WR6200A
100 ps (10 GS/s)
Summed and continuous averaging to 1 million sweeps
From 8.5 to 11 bits vertical resolution
Envelope, floor, or roof for up to 1 million sweeps
Linear or Sinx/x
11
Specifications
Trigger System
Trigger Modes
Sources
Trigger Coupling
Pre-trigger Delay
Post-trigger Delay
Hold-off
Internal Trigger Level Range
Normal, Auto, Single, Stop
Any input channel, External, Ext/10, or Line; slope and level unique to each source, except Line
DC
0–100% of memory size (adjustable in 1% increments, or 100 ns)
Up to 10,000 divisions in real time mode, limited at slower time/div settings in roll mode
2 ns to 20 s or 1 to 1,000,000,000 events
±4.1 div from center (typical)
WR6030A
WR6050A
WR6051A
WR6100A
WR6200A
Trigger Sensitivity with Edge Trigger
(Ch 1-4 + external)
2 div @ < 350 MHz, 2 div @ < 500 MHz, 2 div @ < 500 MHz, 2 div @ < 1 GHz,
2 div @ < 2 GHz,
1 div @ < 250 MHz 1 div @ < 350 MHz 1 div @ < 350 MHz 1 div @ < 750 MHz 1 div @ < 1.8 GHz
Max. Trigger Frequency with
SMART Trigger® (Ch 1-4 + external)
350 MHz
@ ≥ 10 mV
Trigger Level DC Accuracy
External trigger range
500 MHz
@ ≥ 10 mV
500 MHz
@ ≥ 10 mV
750 MHz
@ ≥ 10 mV
750 MHz
@ ≥ 10 mV
±4% full scale ±2 mV (typical)
EXT/10 ±4 V; EXT ±400 mV
Basic Triggers
Edge
Triggers when signal meets slope (positive or negative) and level condition.
SMART Triggers
State or Edge Qualified
Dropout
Pattern
Triggers on any input source only if a defined state or edge occurred on another input source.
Delay between sources is selectable by time or events.
Triggers if signal drops out for longer than selected time between 2 ns and 20 s.
Logic combination (AND, NAND, OR, NOR) of 5 inputs (4 channels and external trigger input – 2 Ch+EXT
on WR6051A). Each source can be high, low, or don’t care.The high and low level can be selected
independently. Triggers at start or end of the pattern.
SMART Triggers with Exclusion Technology
Glitch and Pulse Width
Signal or Pattern Interval
Timeout (State/Edge Qualified)
Exclusion Triggering
Triggers on positive or negative glitches with widths selectable from 600 ps to 20 s or on intermittent
faults (subject to bandwidth limit of oscilloscope).
Triggers on intervals selectable between 2 ns and 20 s.
Triggers on any source if a given state (or transition edge) has occurred on another source.
Delay between sources is 2 ns to 20 s, or 1 to 99,999,999 events.
Trigger on intermittent faults by specifying the normal width or period.
Automatic Setup
Auto Setup
Vertical Find Scale
Automatically sets timebase, trigger, and sensitivity to display a wide range of repetitive signals.
Automatically sets the vertical sensitivity and offset for the selected channels to display a waveform
with maximum dynamic range.
Probes
Probes
Probe System; ProBus
Scale Factors
One PP007-WR-1 per channel standard; Optional passive and active probes available.
Automatically detects and supports a variety of compatible probes.
Automatically or manually selected, depending on probe used
Color Waveform Display
Type
Resolution
Number of Traces
Grid Styles
Waveform Styles
Color 8.4" flat-panel TFT-LCD with high resolution touch screen
SVGA; 800 x 600 pixels
Display a maximum of 8 traces. Simultaneously display channel, zoom, memory, and math traces.
Auto, Single, Dual, Quad, Octal, XY, Single + XY, Dual + XY
Sample dots joined or dots only
Analog Persistence Display
Analog and Color-Graded Persistence
Persistence Selections
Trace Selection
Persistence
Sweeps Displayed
Variable saturation levels; stores each trace’s persistence data in memory.
Select analog, color, or three-dimensional.
Activate persistence on all or any combination of traces.
Aging time select from 500 ms to infinity.
All accumulated, or all accumulated with last trace highlighted.
12
Specifications
Zoom Expansion Traces
Display up to 4 Zoom/Math traces
CPU
Processor
Processing Memory
Operating System
Intel® Celeron,® 2.0 GHz or better.
256 MB on Std and M option; 512 MB with L and VL options
Microsoft Windows® XP Professional
Internal Waveform Memory
M1, M2, M3, M4 Internal Waveform Memory (store full-length waveform with 16 bits/data point)
or store to any number of files limited only by data storage media.
Setup Storage
Front Panel and Instrument Status
Store to the internal hard drive, over the network, or to a USB-connected peripheral device.
Interface
Remote Control
GPIB Port (Optional)
Ethernet Port
USB Ports
External Monitor Port
Parallel Port
Serial Port
Via Windows Automation, or via LeCroy Remote Command Set
Supports IEEE – 488.2
10/100Base-T Ethernet interface (RJ-45 connector)
5 USB 2.0 ports (one on front of instrument) supports Windows-compatible devices.
Standard 15-pin D-Type SVGA-compatible DB-15; connect a second monitor to use
dual-monitor display mode.
Standard DB-25
DB-9 RS-232 port (not for remote oscilloscope control)
Auxiliary Input
Signal Types
Coupling
Maximum Input Voltage
Selected from External Trigger or External Clock input on front panel
50 Ω: DC, 1 MΩ: AC, DC, GND
50 Ω: 5 Vrms, 1 MΩ: 250 V max. (Peak AC: ≤ 10 kHz + DC)
Auxiliary Output
Signal Type
Output Level
Connector Type
Trigger Enabled, Trigger Output. Pass/Fail, or Off
TTL, ≈3.3 V
BNC, located on rear panel
General
Auto Calibration
Calibrator
Power Requirements
Ensures specified DC and timing accuracy is maintained for 1 year minimum.
Output available on front panel connector provides a variety of signals for probe calibration
and compensation.
100–240 Vrms at 50/60 Hz; 115 Vrms (±10%) at 400 Hz, Automatic AC Voltage Selection
Installation Category: 300V CAT II; Max. Power Consumption: 400 VA/400 W; 350 VA/350 W
for WaveRunner 6051A
Environmental
Temperature: Operating
Temperature: Non-Operating
Humidity: Operating
Humidity: Non-Operating
Altitude: Operating
Altitude: Non-Operating
+5 °C to 40 °C
-20 °C to +60 °C
5% to 80% RH (non-condensing) up to 30 °C, Upper limit derates linearly
to 45% RH (non-condensing) at 40 °C
5% to 95% RH (non-condensing) as tested per MIL-PRF-28800F
3,048 m (10,000 ft.) max at ≤ 25 °C
12,190 m (40,000 ft.)
Physical
Dimensions (HWD)
Net Weight
Shipping Weight
211 mm x 355 mm x 363 mm (excluding feet) 8.3" x 13.8" x 14.3"
10 kg. (22 lbs.), excluding printer
less than 13.6 kg. (30 lbs.)
Certifications
CE Compliant, UL and cUL listed; Conforms to EN 61326-1, EN 61010-1, UL 3111-1,
and CSA C22.2 No. 1010.1.
Warranty and Service
3-year warranty; calibration recommended annually. Optional service programs include extended warranty,
upgrades, calibration, and customization services.
13
Ordering Information
WaveRunner 4-Channel/2-Channel Oscilloscopes
2 GHz, 4 Ch, 5 GS/s, 4 Mpts/Ch (10 GS/s, 8 Mpts/2 Ch)
Color with Windows® XP Pro
1 GHz, 4 Ch, 5 GS/s, 4 Mpts/Ch (10 GS/s, 8 Mpts/2 Ch)
Color with Windows XP Pro
500 MHz, 4 Ch, 5 GS/s, 4 Mpts/Ch (8 Mpts/2 Ch)
Color with Windows XP Pro
500 MHz, 2 Ch, 5 GS/s, 4 Mpts/Ch (8 Mpts/1 Ch)
Color with Windows XP Pro
350 MHz, 4 Ch, 2.5 GS/s, 4 Mpts/Ch (5 GS/s, 8 Mpts/2 Ch)
Color with Windows XP Pro
Included with Standard Configuration
÷10 HiZ 500 MHz Passive Probe (Total of 1 Per Channel)
Getting Started Manual
CD-ROM containing Operator’s Manual,
Remote Control Manual, and Automation Manual
CD-ROMs containing Utility Software
Optical 3-button Wheel Mouse – USB
Standard Ports; 10/100Base-T Ethernet, USB 2.0 (5),
Parallel, RS-232, SVGA Video out, Audio in/out
Protective Front Cover
Standard Commercial Calibration and Performance Certificate
3-Year Warranty
Product Code
WaveRunner
6200A
WaveRunner
6100A
WaveRunner
6050A
WaveRunner
6051A
WaveRunner
6030A
PP007-WR-1
Memory Options
24 Mpts max. when interleaved, 12 Mpts/Ch
(for use with 4 Ch WaveRunner 6000A)
24 Mpts max., 2 Ch 12 Mpts/Ch Memory Option
16 Mpts max. when interleaved, 8 Mpts/Ch
(for use with 4 Ch WaveRunner 6000A)
16 Mpts max., 2 Ch 8 Mpts/Ch Memory Option
Software Options
Disk Drive Measurement Software Package
Digital Filter Software Package
Ethernet Test Software Package (WR6200A Only)
Jitter and Timing Analysis Software Package
PowerMeasure Analysis Software Package
EMC Pulse Parameter Software Package
Serial Data Mask Software Package
USB 2.0 Compliance Test Software Package (WR6200A Only)
Intermediate Math Software Package
Advanced Math Software Package
Advanced Customization Software Package
Value Analysis Software Package (Includes XWAV and JTA2)
Master Analysis Software Package
WR6-VL
WR6-VL2
WR6-L
WR6-L2
WR6-DDM2
WR6-DFP2
WR6-ENET
WR6-JTA2
WR6-PMA2
WR6-EMC*
WR6-SDM†
WR6-USB2
WR6-XWAV
WR6-XMATH
WR6-XDEV
WR6-XVAP
WR6-XMAP
(Includes JTA2, XMATH and XDEV)
Processing Web Editor Software Package
for Functions and Parameters
WR6-XWEB
* WR6-EMC is compatible with all WaveRunner 6000A oscilloscopes except the WR6030A.
† WR6200A oscilloscope required for full mask testing capability; lower bandwidth
models will have reduced capabilities.
Hardware and Software Options
32 Digital Channel Oscilloscope Mixed Signal Option
CANbus TDM Trigger, Decode and Measure/Graph
Testing Option
CANbus TD Trigger and Decode Testing Option
MS-32*
CANbus TDM
CANbus TD
*MS-32 is compatible only with WR6000A 4-channel oscilloscopes.
Probes and Probe Accessories Options
Product Code
2.5 GHz, 0.7 pF Active Probe (÷10), Small Form Factor
HFP2500
1.5 GHz, 0.7 pF Active Probe (÷10), Small Form Factor
HFP1500
1 GHz, 0.7 pF Active Probe (÷10), Small Form Factor
HFP1000
WaveLink® 4 GHz Differential Probe
D300A-AT*
with Adjustable Tip Module
WaveLink 4 GHz, 5 V Differential Probe with Small Tip Module
D350ST*
WaveLink ProBus Probe Body
WL300
1 GHz Active Differential Probe (÷1, ÷10, ÷20)
AP034
500 MHz Active Differential Probe (x10, ÷1, ÷10 or ÷100)
AP033
30 A; 100 MHz Current Probe – AC/DC; 30 Arms;
CP031
50 A Peak Pulse
30 A; 50 MHz Current Probe – AC/DC; 30 Arms;
CP030
50 A Peak Pulse
AP015
30 A; 50 MHz Current Probe – AC/DC; 30 Arms Peak;
50 A Peak Pulse
150 A; 10 MHz Current Probe – AC/DC; 150 Arms;
CP150
500 A Peak Pulse
500 A; 2 MHz Current Probe – AC/DC; 500 Arms;
CP500
700 A Peak Pulse
1,400 V, 100 MHz Differential Probe
ADP305
1,400 V, 20 MHz Differential Probe
ADP300
Basic Adapter Kit for PP007-WR-1 and PP007-WS-1
PK701
Advanced Adapter Kit for PP007-WR-1 and PP007-WS-1
PK702
SMD Adapter Kit for PP007-WR-1 and PP007-WS-1
PK703
Microclip Kit for PP007-WR-1 and PP007-WS-1
PK704
1 Ch 100 MHz Differential Amplifier
DA1855A
with Precision Voltage Source
*For a complete probe, order a WL300 Probe Body with the Probe Tip Module.
Only applicable with the WR6200A oscilloscope.
Hardware Options and Accessories
IEEE-488 GPIB Interface Upgrade
Graphics Printer
Removable Hard Drive
CD-RW Upgrade
Graphic Printer Retrofit
USB Floppy Drive
Hard Transit Case
Soft Carrying Case
Rackmount, 6U High
Accessory Pouch
Mini Keyboard, USB
USB Flash Memory
Video Trigger Module
Oscilloscope Cart with Additional Shelf and Drawer
Oscilloscope Cart
Ethernet Compliance Fixture for 10Base-T
Ethernet Compliance Fixture for 100Base-T/1000Base-T
[Includes a Set of 2 Test Fixtures Signals on
Twisted Pair Cables (UTP)]
Telecom Adapter Kit 100 Ω Bal., 120 Ω Bal., 75 Ω Unbal.
USB 2.0 Testing Compliance Test Fixture
WR6-GPIB
WR6A-GP
WR6-RHD
WR6-CDRW
WR6A-RK-GP
WR6-FLPY
WR6-HARD
WR6-SOFT
WR6-RACK
WR6-POUCH
WR6-KBD
MEM-USB
VT75
OC1024
OC1021
TF-10BT
TF-ENET
TF-ET
TF-USB
Customer Service
LeCroy oscilloscopes are designed, built, and tested to ensure high
reliability. In the unlikely event you experience difficulties, our digital
oscilloscopes are fully warranted for three years.
This warranty includes:
• No charge for return shipping
• Long-term 7-year support
• Upgrade to latest software at no charge
1-800-5-LeCroy www.lecroy.com
Local sales offices are located throughout the world.
To find the most convenient one visit www.lecroy.com
© 2006 by LeCroy Corporation. All rights reserved. Specifications subject to change without notice.
Other product or brand names are trademarks or requested trademarks of their respective holders.
WR6KADSrevA_W1_06Jun06