USA_SDC2 Installation Checklist

USA_SDC2 Installation Checklist
from
STELLA espresso
installation checklist
MODEL
Stella di Caffè
2 GROUP
PRODUCT CODE : SDC2
Quick Reference Specifications:
Dimensions: 22.5”(H)X 23.6”(L)X 31”(W)
Weight: 176 lbs (full)
Electrical Requirements: Volts: 208-240/Watts: 6700/Amps: 30
Plumbing Requirements: Flow: 30GPH (minimum) Pressure: 20psi
(minimum) Hardness: 3 GPG (maximum) Fitting: ½” MPT w/shut-off
Drainage Requirements: Open gravity drain of 1.25” ID (min) within 4
feet of machine.
The following information will assist you in preparing your location for the installation of your equipment.
Please make sure everything is prepared to these specifications prior to scheduling your installation.
Once everything is complete, check the appropriate boxes and sign the bottom of the form.
COUNTER SPACE REQUIREMENTS:
CONFIRMED – 2.5” ACCESS HOLE IS IN PLACE
PLEASE NOTE: There are 4 inch
leg extensions shipped with the
machine, but not installed. Their
use is optional, but highly
recommended for ease of
cleaning under the unit.
WATER REQUIREMENTS:
CONFIRMED - WATER HARDNESS LEVEL ________________GPG
*Machine must be supplied with a minimum of 30 Gallons per hour @ 20 PSI.
*For examples of appropriate supply fittings, see examples at left.
*If water hardness levels exceed 3 GPG (Grains per Gallon) a water softener MUST be installed.
Exceeding these levels will void the manufacturer’s warranty. (Check appropriate box below)
I have tested the water hardness and it is 3 GPG or less (see above).
I already have a suitable water softener and its output is 3 GPG or less (see above).
I have tested the water hardness level and it is written above. Please supply me
with the appropriate water softener at time of installation.
ELECTRICAL REQUIREMENTS:
208-240V/30AMP/6700WATT
Dedicated 30 AMP Plug within 4
feet of installation location.
PLEASE NOTE: The machine will
not be supplied with a Cord Cap
(Male plug). The outlet to the
right is recommended.
CONFIRMED
DRAINAGE REQUIREMENTS: CONFIRMED
Access to open gravity drain no smaller than
1.25” ID (Inner Diameter). Drain MUST be
within 4 feet of the machine for proper
drainage.
By signing below, I am confirming that all installation requirements have been met. I also understand that if all
the requirements have not been met, I may be subject to additional installation and travel charges beyond the
original estimate.
Signature
Printed Name
Date