OM-BRII90
BRIARWOD BRII/90
SOLID FUEL STOVE
This heater meets the 2015 U.S. Environmental Protection Agency’s particulate emission limits for wood heaters sold after May 15, 2015.
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please SAVE THESE INSTRUCTIONS for future reference.
The authority having jurisdiction (such a municipal building department, fire department, etc.) should be
consulted before installation to determine the need to obtain a permit.
OPERATION & INSTALLATION MANUAL
Manufactured By
Valley Comfort Systems Inc., 1290 Commercial Way, Penticton, BC, V2A 3H5, Canada
Phone: 250-493-7444  Fax: 250-493-5833  www.blazeking.com  info@blazeking.com
Pour la version française de nos manuels S.V.P. vous référez à notre site web: www.blazeking.com
OM-BRII90 E V1.04 wo768
August 25, 2015
BRII/90
Page 2
TABLE OF CONTENTS
INTRODUCTION _____________________________________________________________ 4
SPECIFICATIONS _____________________________________________________________ 5
EMISSIONS __________________________________________________________________ 5
PRODUCT INFORMATION _____________________________________________________ 6
APPLIANCE DIMENSIONS—Briarwood ........................................................................................ 6
CERTIFICATION LABEL________________________________________________________ 7
SAFETY PRECAUTIONS ________________________________________________________ 8
INSTALLATION INSTRUCTIONS _________________________________________________ 11
PARTS INCLUDED WITH THE BRIARWOOD .............................................................................. 11
OPTIONAL EQUIPMENT ............................................................................................................... 11
DECORATIVE OPTIONS ................................................................................................................ 11
FLOOR PROTECTION .................................................................................................................... 11
MINIMUM CLEARANCES for BRII/90........................................................................................... 12
COMBUSTION AIR ......................................................................................................................... 13
DRAFT ............................................................................................................................................. 13
ROLE OF THE CHIMNEY............................................................................................................... 13
VENTING SYSTEMS ...................................................................................................................... 14
MOBILE HOME (AND RESIDENTIAL ALCOVE INSTALLATIONS) ........................................... 17
OPTIONAL ACCESSORIES ............................................................................................................. 18
OPERATING INSTRUCTIONS ___________________________________________________ 20
YOUR FIRST FIRE! .......................................................................................................................... 20
SELECTING WOOD ........................................................................................................................ 20
HOW TO USE MOISTURE METERS .............................................................................................. 21
EFFICIENCY.................................................................................................................................... 21
LIGHTING THE FIRE ..................................................................................................................... 22
RELOADING PROCEDURE ............................................................................................................ 22
FAN OPERATION ........................................................................................................................... 23
ICE - FORMATION AND PREVENTION ....................................................................................... 23
WOOD BURNING IN THE SHOULDER SEASON ......................................................................... 23
MAINTENANCE ______________________________________________________________ 24
RUN-AWAY OR CHIMNEY FIRE .................................................................................................... 24
CREOSOTE FORMATION AND REMOVAL .................................................................................. 24
CHIMNEY MAINTENANCE........................................................................................................... 25
FIRE EXTINGUISHERS AND SMOKE DETECTORS ..................................................................... 25
ASH REMOVAL ............................................................................................................................... 25
LOADING DOOR GASKET INSPECTION...................................................................................... 26
LOADING DOOR GASKET REPLACEMENT................................................................................. 26
DOOR GLASS GASKET INSPECTION ........................................................................................... 27
DOOR GLASS GASKET REPLACEMENT ...................................................................................... 27
DOOR GLASS, CLEANING ............................................................................................................. 27
LOADING DOOR TENSION ADJUSTMENT ................................................................................. 28
BAFFLE REPLACEMENT................................................................................................................ 29
OM-BRII90 E V1.04 wo768
August 25, 2015
BRII/90
Page 3
TABLE OF CONTENTS cont.
CHIMNEY DRAFTS ........................................................................................................................ 29
OPTIONAL FAN ASSEMBLY .......................................................................................................... 29
TROUBLESHOOTING__________________________________________________________ 30
WARRANTY _________________________________________________________________ 34
INSTALLER NOTES ____________________________________________________________ 40
OM-BRII90 E V1.04 wo768
August 25, 2015
BRII/90
Page 4
INTRODUCTION
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
THIS APPLIANCE IS HOT WHEN OPERATED AND CAN CAUSE SEVERE BURNS IF CONTACTED.
ANY CHANGES OR ALTERATIONS TO THIS APPLIANCE OR ITS CONTROLS CAN BE DANGEROUS AND IS
PROHIBITED BY FEDERAL AND STATE LAWS.
Do not operate appliance before reading and understanding operating instructions. Failure to operate appliance according to
operating instructions could cause fire or injury.
Before installing this appliance, contact the local building or fire authority and follow their guidelines.
This appliance must be installed by a qualified installer.
Risk of burns. The appliance should be turned off and cooled before servicing.
Do not operate without fully assembling all components.
Do not let the appliance become hot enough for any part to glow red.
Do not install damaged, incomplete or substitute components.
Risk of cuts and abrasions. Wear protective gloves and safety glasses during installation. Sheet metal edges may be sharp.
Children and adults should be alerted to the hazards of high surface temperature and should stay away to avoid burns or
clothing ignition.
Young children should be carefully supervised when they are in the same room as the appliance. Toddlers, young children
and others may be susceptible to accidental contact burns. A physical barrier is recommended if there are at risk individuals
in the house. To restrict access to an appliance or stove, install an adjustable safety gate to keep toddlers, young children and
other at risk individuals out of the room and away from hot surfaces.
Clothing or other flammable material should not be placed on or near the appliance. Objects placed in front of the appliance
must be kept a minimum of 48” away from the front face of the appliance.
Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies.
Ensure you have incorporated adequate safety measure to protect infants / toddlers from touching hot surfaces.
Even after the appliance is out, all surfaces, including the glass and/or any attachment will remain hot for an extended period
of time.
Check with your local hearth specialty dealer for safety hearth guards to protect children from hot surfaces. These guards
must be fastened to a wall and/or to the floor.
Any safety guard removed for servicing must be replaced prior to operating the appliance.
Under no circumstances should this appliance be modified.
This appliance must not be connected to a chimney flue pipe servicing a separate solid fuel burning appliance.
Do not operate the appliance with the glass door removed, cracked or broken. Replacement of the glass should be done by a
licensed or qualified service person.
Do not strike or slam shut the appliance glass door.
Operate only with the doors tightly closed.
Stove will over-fire if door is not shut and latched.
Only certified doors / optional fronts / and surrounds for inserts with the unit are to be installed on the appliance.
Keep the packaging material out of reach of children and dispose of the material in a safe manner. As with all plastic bags,
these are not toys and should be kept away from children and infants.
If the appliance is not properly installed, a house fire may result. Do not expose the appliance to the elements (ex. rain, etc.)
and keep the appliance dry at all times.
The chimney must be sound and free of cracks and obstructions. Clean your chimney regularly as required.
Never use gasoline, gasoline-type lantern fuel, kerosene, charcoal lighter fluid, or similar liquids to start or ‘freshen up’ a fire in
this heater. Keep all such liquids well away from the heater while it is in use.
Your appliance requires periodic maintenance and cleaning. Failure to maintain your appliance may lead to smoke spillage in
your home.
Higher efficiencies and lower emissions will generally result when burning air dried seasoned woods, as compared to wet,
green or freshly cut wood. Burning wet unseasoned wood can cause excessive creosote accumulation. When ignited it can
cause a chimney fire that may result in a serious house fire.
The appliance is designed to burn natural wood only. Do not burn treated wood, coal, charcoal, colored paper, cardboard,
solvents or garbage.
Burn wood directly on the firebricks. Do not use a grate or elevate the fire.
Do not store wood within appliance installation clearances or within the space required for re-fueling and ash removal.
Ashes must be disposed in a metal container with a tight lid and placed on a non-combustible surface well away from the
home or structure until completely cool.
OM-BRII90 E V1.04 wo768
August 25, 2015
BRII/90
Page 5
SPECIFICATIONS
Model
BRII/90 (non-catalytic)
Height
30 7/8” (785 mm)
Width
27 1/2” (699 mm) (without door handle)
Depth
22 7/8” (581 mm) (without optional fan kit)
28 5/8” (727 mm) (with optional fan kit)
Flue collar
6” I.D.
Recommended flue draft
.05” water column (on high burn)
Fire door opening
21 13/16” x 10” (554 mm x 254 mm)
Firebox depth
12 1/2” (318 mm) brick to brick, 14 5/8” (372 mm) brick to glass
Firebox width
22 1/2” (572 mm)
Firebox height
12” (305 mm)
Fire box capacity
2.1 cu. ft.
Recommended Fuel length
22” (559 mm)
Wood capacity (approximate):
White oak - 44 lbs. (19.96 kg)
Fir - 35 lbs. (15.88 kg)
Construction
3/16” & 1/4” firebox, brick lined
18 gauge outer shields
Shipping Weight
330 lbs. (150 kg)
Chimney recommendation
15’ from stove top to chimney cap.
This unit was tested and listed UL 1482-1988 and ULC S627-M93 by EMISSIONS CO Average(%)
g/hr
Intertek testing laboratories.
Low Burn
1.11
1.66
This manual describes the installation and operation of the
Med-low Burn
0.92
3.481
Briarwood BRII/90 wood heater.
Med-high Burn
0.69
2.6
This heater is certified to comply with the 2015 U.S. Environmental
High Burn
0.33
7.682
Protection Agency’s particulate emission limits for wood heaters sold
after May 15, 2015.
Under specific test conditions this heater has been shown to deliver heat at rates ranging from 10600 to 36000 Btu/hr.
This wood heater has a manufacturer-set minimum low burn rate that must not be altered. It is against federal regulations
to alter this setting or otherwise operate this wood heater in a manner inconsistent with operating instructions in this
manual.
It is against federal regulations to operate this wood heater in a manner inconsistent with operating instructions in this
manual.
OM-BRII90 E V1.04 wo768
August 25, 2015
BRII/90
Page 6
PRODUCT INFORMATION
APPLIANCE DIMENSIONS—Briarwood
ZRSWLRQDOIDQV
OM-BRII90 E V1.04 wo768
August 25, 2015
BRII/90
Page 7
CERTIFICATION LABEL
BRIARWOOD II/90 STOVE
WH -
LISTED ROOM HEATER, SOLID FUEL TYPE
Also for use in MOBILE HOMES
MODEL: BRII/90 Tested to : UL1482-1998 / ULC S627-M93 CERTIFIED IN BOTH UNITED STATES AND CANADA
PREVENT HOUSE FIRES - Install and use only in accordance with Blaze King’s installation and operation instructions. Contact local building or fire officials about
restrictions and installation inspection in your area.
CHIMNEYS: DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE. Chimney must be a minimum of 6” listed factory built chimney
suitable for use with solid fuels and conforming to, ULC629 in Canada or UL-103HT in the USA. If a non-listed chimney is to be used it must comply with all local
and national codes, in Canada a non -listed chimney requires a full reline with a listed solid fuel chimney liner.
Mobile Home, residential close clearance, and residential alcove installations require 6” listed double wall close clearance chimney connector, with matching
listed factory built chimney suitable for use with solid fuels and conforming to, ULC629 in Canada or UL-103HT in the
. USA
Mobile Home installations are only allowed with a roof exit. Do not install in a sleeping room.
Alcove minimum width 55.5” / 1410 mm , minimum height from top of stove 36” / 914 mm, maximum depth 32” / 813 mm.
Passing through a wall or ceiling requires special methods: see local building codes.
DO NOT PASS A CHIMNEY CONNECTOR THROUGH A COMBUSTIBLE WALL OR CEILING.
Electrical rating: 115 VAC, 60 Hz, 0.58 Amps. Risk of electrical shock. Disconnect power before servicing unit. Do not route power cord in front of or beneath
heater.
MINIMUM CLEARANCES TO COMBUSTIBLES (See owners manual for complete description of all requir ements)
Residential Installations
A
B
C
D
E
Single Wall Pipe (24 MSG Black)
15” / 381 mm
15” / 381 mm
25.75” / 654 mm
18” / 457 mm
15” / 381 mm
Listed Double Wall Pipe—Close Clearances
Use side shields and rear shield.
(Must use for Mobile / Manufactured Home
Installations, Alcove Installation and Close
Clearance Installations)
14” / 356 mm
8” / 203 mm
24.75” / 629 mm
11” / 279 mm
8” / 203 mm
** Mobile Home and Alcove Installations must use double wall listed pipe, side shields and rear shield. Mobile Home Installations
require Outside Combustion Air Kit# Z1526.
Floor protection may be any non-combustible material or Listed Floor Prot ector, and must extend at least 18” / 406 mm in front of the
loading door opening. Minimum size is 44x 36”.
U.S. ENVIRONMENTAL PROTECTION AGENCY- Certified to comply with July, 1990 particulate emission standards.
*Operate with doors closed. Open door to feed fire ONLY. Do not obstruct combustion air openings. Provide adequate outside air
for combustion.* Use only high temp erature ceramic glass if replacement is necessary, 5 mm. thickness
KEEP FURNISHINGS AND OTHER COMBUSTIBLE MATERIALS WELL AWAY FROM HEATER. DO NOT
OVERFIRE! IF HEATER OR CHIMNEY GLOWS YOU ARE OVERFIRING.
For use with solid fuel only. Use of other fuels may cause a house fire or endanger your safety.
Refer to Installation and Operations manual for installation and operation instructions.
CAUTION:
HOT WHILE IN OPERATION. DO NOT TOUCH. KEEP CHILDREN, CLOTHING AND FURNITURE
AWAY. CONTACT MAY CAUSE SKIN BURN. READ THIS LABEL AND INSTRUCTION MANUAL BEFORE
OPERATION OF STOVE.
19"
MANUFACTURED IN:
USA:
Blaze King Industries
146A Street
Walla Walla, WA.
99362
Canada:
Valley Comfort Systems
1290 Commercial Way
Penticton, B.C.
V2A 3H5
MANUFACTURE DATE
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
DEC
2001
2002
2003
2004
2005
0164
OM-BRII90 E V1.04 wo768
2006
Rev 08/2001
August 25, 2015
BRII/90
Page 8
SAFETY PRECAUTIONS
IF THIS BLAZE KING STOVE IS NOT PROPERLY INSTALLED OR OPERATED, A HOUSE FIRE MAY
RESULT. TO REDUCE THE RISK OF FIRE, FOLLOW THE INSTALLATION INSTRUCTIONS. CONTACT LOCAL
BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION
REQUIREMENTS IN YOUR AREA.
PLEASE READ THIS ENTIRE MANUAL BEFORE YOU INSTALL AND USE YOUR NEW ROOM HEATER. FAILURE
TO FOLLOW INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE, BODILY INJURY, OR EVEN DEATH.
This appliance must be connected to a listed high temperature (ULC629 IN CANADA OR
UL-103HT IN THE USA) residential type factory built solid fuel chimney or an approved
masonry chimney with a flue liner.
Chimney and chimney connector must be in good condition and kept clean.
NEVER vent the stove to other rooms of the building. Must be vented to the outside ONLY.
NEVER use a chimney or chimney connector smaller then the stove exhaust, unless
approved by your local inspector.
NEVER vent the stove into a “Class B” gas vent chimney.
DO NOT CONNECT IN CONJUNCTION WITH ANY AIR DISTRIBUTION DUCTWORK
UNLESS SPECIFICALLY APPROVED FOR SUCH INSTALLATIONS.
Inspect the chimney connector and chimney regularly during each burning season and
clean when necessary.
DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE.
NEVER intentionally start a chimney fire to clean the flue.
When installed in a mobile home, this appliance must be bolted to the floor and provided
with outside air.
WARNING: DO NOT INSTALL IN A SLEEPING ROOM
CAUTION: THE STRUCTURAL INTEGRITY OF THE MOBILE HOME
FLOOR, WALL, AND CEILING/ROOF MUST BE MAINTAINED.
Check with local building officials.
If the Optional Fan Kit is
installed, connect this unit to
a properly grounded, 110-volt
electrical outlet. Do not route
the power cord in front of or
under the stove.
OM-BRII90 E V1.04 wo768
Do not make any changes or
modifications to an existing
masonry fireplace or chimney
to install this appliance. Do
not make any changes to
the appliance to increase
combustion air.
August 25, 2015
BRII/90
Page 9
SAFETY PRECAUTIONS cont.
Never try to repair or replace
any part of this appliance
unless instructions are given
in this manual. All other work
must be done by a trained
technician.
Do not place clothing or other
flammable items on or near
this appliance.
Allow the appliance to cool
down before carrying out any
maintenance or cleaning.
DO NOT OVER FIRE THIS
HEATER. Attempts to
achieve heat output rates
that exceed heater design
specifications can result
in permanent damage to
the heater. Over firing the
appliance may cause a house
fire. Never burn the stove so
hot that the stove or chimney
connector begins to glow.
Maintain the door and glass
seal and keep them in good
condition. A leaking door seal
will shorten burn times.
Avoid placing wood against
the glass when loading. Do
not slam the door or strike the
glass.
Do not throw this manual
away. This manual has
important operating and
maintenance instructions that
you will need at a later time.
Always follow the instructions
in this manual.
Do not use a grate or other
device to elevate the fire off of
the firebox floor. Burn the fire
directly on the bricks.
Ashes should be placed in a
steel container with a tightly
fitting lid and moved outdoors
immediately. If the ashes are
disposed of by burial in soil or
otherwise locally dispersed,
they should be retained in
the closed container until
all cinders have thoroughly
cooled. Other waste shall not
be placed in this container.
It is recommended to install smoke and carbon monoxide detectors where heaters are
installed. Install at least one smoke detector on each floor of your home to ensure your
safety. It should be located away from the wood stove and close to the sleeping areas.
Locating a smoke detector too close to a wood stove can cause the smoke detector alarm
to sound if a puff of smoke is emitted while the wood stove door is open during reloading.
Follow the smoke detector manufacturers placement, installation, and maintenance
instructions.
OM-BRII90 E V1.04 wo768
August 25, 2015
BRII/90
Page 10
SAFETY PRECAUTIONS cont.
This appliance is designed and approved for burning cord wood only. DO NOT burn trash,
garbage; artificial or paper logs; gift wrappings; coal; lighter fluids; chemical cleaners;
chemical starters; treated or painted wood; salt water driftwood or foil-backed paper such
as gum wrappers or cigarette packages; lawn clippings or yard waste; materials containing
rubber (including tires), plastic, asbestos; waste petroleum products, paints or paint
thinners, or asphalt products; construction or demolition debris; railroad ties or pressuretreated wood; manure or animal remains; unseasoned wood or paper products, cardboard,
plywood, or particleboard. The prohibition against burning these materials does not prohibit
the use of fire starters made from paper, cardboard, saw dust, wax and similar substances
for the purpose of starting a fire in an affected wood heater. Burning these materials may
result in the release of toxic fumes or render the heater ineffective and cause smoke. Burn
natural wood only. It will void all warranties and safety listings.
Never burn the stove with the
loading door open.
Never block free airflow
through vents on this
appliance.
OM-BRII90 E V1.04 wo768
Never use gasoline, gasolinetype lantern fuel, kerosene,
charcoal lighter fluid, or similar
liquids to start or ‘freshen up’ a
fire in this heater.
Keep all such liquids well away
from the heater while it is in use.
Some fuels could generate
carbon monoxide and are very
dangerous.
HOT WHILE IN OPERATION.
KEEP CHILDREN,
CLOTHING AND FURNITURE
AWAY.
CONTACT MAY CAUSE SKIN
BURNS.
Do not touch the appliance
when it is hot and educate all
children of the danger of a
high temperature appliance.
Young children should be
supervised when they are
in the same room as the
appliance.
Keep furniture, curtains,
wood, paper and other
combustibles a minimum of
48in (1219mm) away from
the front of the appliance.
ALSO, DO NOT STORE
COMBUSTIBLES UNDER
THE APPLIANCE (WOOD,
PAPER etc.).
This appliance must be
properly installed to prevent
the possibility of a house
fire. The instructions must
be strictly adhered to. Do not
use makeshift methods or
compromise in the installation.
Contact local building officials
to obtain a permit and
information on any installation
restriction or inspection
requirements in your area.
Notify your insurance
company as well.
August 25, 2015
BRII/90
Page 11
INSTALLATION INSTRUCTIONS
•
•
•
•
•
BEFORE INSTALLING THIS APPLIANCE, CONTACT THE LOCAL BUILDING OR FIRE OR OTHER
AUTHORITY HAVING JURISDICTION AND FOLLOW THEIR GUIDELINES.
THIS APPLIANCE MUST BE INSTALLED BY A QUALIFIED INSTALLER. FOLLOW THE
INSTALLATION DIRECTIONS. DO NOT OPERATE WITHOUT FULLY ASSEMBLING ALL
COMPONENTS.
IF THIS APPLIANCE IS NOT PROPERLY INSTALLED, A HOUSE FIRE MAY RESULT.
THIS APPLIANCE IS HOT WHEN OPERATED AND CAN CAUSE SEVERE BURNS IF
CONTACTED. CHILDREN AND PETS MUST BE KEPT FROM TOUCHING THE APPLIANCE
WHEN IT IS HOT.
COMBUSTIBLE MATERIAL SUCH AS FIRE WOOD, WET CLOTHING, ETC. PLACED TOO CLOSE
CAN CATCH FIRE. OBJECTS PLACED IN FRONT OF THE APPLIANCE MUST BE KEPT A
MINIMUM OF 48”(1219 MM) FROM THE FRONT OF THE APPLIANCE.
Blaze King grants no warranty, implied or
stated, for the installation or maintenance of the
appliance and assumes no responsibility of any
consequential damage(s).
PARTS INCLUDED WITH THE BRIARWOOD
1.
2.
1.
3.
1.
Poker
Manual kit (w/ warranty cards, fire starter)
OPTIONAL EQUIPMENT
Fan kit (Z1514)
2.
Rear shield (ZRSBRII)
Side shields (ZSSBRII, requires rear sheild)
DECORATIVE OPTIONS
Door trim kit gold
2.
Door trim kit satin
FLOOR PROTECTION
If the stove sits on a combustible floor, a non-combustible shield must be used underneath the
stove and extending 16” out from the front and 8” on either side of the fuel-loading door in the
USA. In Canada a non-combustible shield must be used underneath the stove and extending 8”
on either side and rear and 18” out in front of the loading door.
A non-combustible shield is also required underneath the chimney connector and extending at
least 2” (50.8mm) on either side of the chimney connector.
See the next page for minimum sizes depending on model. This floor protection is required to
prevent sparks from falling onto the combustible floor. See CSA B365-M87). This product does
not require thermal hearth pad protection.
OM-BRII90 E V1.04 wo768
August 25, 2015
BRII/90
Page 12
INSTALLATION INSTRUCTIONS cont.
MINIMUM CLEARANCES for BRII/90
Residential Installations
Single wall pipe (24 MSG Black).
Listed double wall pipe - close clearances. Use side shields and rear
shield. (Must use for mobile / manufactured home installations. Alcove
Installation and close clearance installations)
A
B
C
D
E
F
15”
381 mm
15”
381 mm
28.75”
731 mm
22”
559 mm
15”
381 mm
28.875”
734 mm
14”
356 mm
8”
204 mm
27.75”
705 mm
15"
381 mm
8”
203 mm
21.875”
556 mm
Check with local codes and pipe manufacturer for pipe clearances. In Canada, 18” clearances from single wall pipe is required.
Mobile home and alcove installations must use double wall listed pipe, side shields, and rear shield.
Mobile home installations also require an outside air kit #Z1526
.
2"
I
I
G
E
B
D
-
C
A
H
F
*2
*1
0,1IW
G
G
*1
H
1
1
*1= 3 2" in Canada and 2 8" in USA
5
5
*2 = 65 8" in Canada and 63 8" in USA
IW5(&200(1'('
G = 5 3/8” (137mm) in USA
8” (203mm) in Canada
H = 16” (406mm) in USA
18” (456mm) in Canada
I = 0” (0mm) in USA
8” (203mm) in Canada
K = 18” (456mm) for single wall pipe in Canada
Ember protection shield (not required to have an insulation value)
is to be listed under UL 1618-2009 (type 1) and must have a minimum size of:
In USA:
38 1/4”wide x 33 3/4”deep (972 x 858 mm)
In Canada: 43 1/2”wide x 43 3/4”deep (1105 x 1112 mm)
Min. Alcove minimum width 55 1/2”, maximum depth 32”, minimum height above stove top 36”
This stove must be installed in compliance with all local codes and regulations.
OM-BRII90 E V1.04 wo768
August 25, 2015
BRII/90
Page 13
INSTALLATION INSTRUCTIONS cont.
COMBUSTION AIR
Ensure adequate combustion air allowing for all other exhausting type appliances in the dwelling (range hoods,
dryers, etc.). In air tight homes and modern constructions, careful considerations must be taken into account
when using a wood burning appliance. Heat recovery ventilators (HRV) systems along with constant running
pan motors in air handlers must be taken into account when balancing the system. Failure to do so may result in
air starvation, smoke spillage and carbon monoxide threats. Consult a HVAC specialist for proper installation.
Ensure adequate combustion air allowing for all other exhausting type appliances in the dwelling (range hoods,
dryers, etc.). In airtight houses it is recommended to install a fresh air inlet into the room where the stove is
located, to prevent air starvation.
DRAFT
Draft in the chimney system is initiated by the air pressure difference between the top and bottom of the
chimney. Heat generated within the firebox will rise and accelerate the draft in the chimney. Recommended
draft is .05 in. w.c. operated on high. Too little draft results in a sluggish fire and smoke spillage into the room
when the stove door is opened. Too much draft (over 0.06 in. w.c.) makes it unsafe to operate the stove and will
void manufacturers warranty.
ROLE OF THE CHIMNEY
Without a proper installed chimney, this appliance will not burn correctly.
The role of the chimney is to pull the proper amount of air into the firebox for the purpose of complete
combustion. Incomplete combustion will lead to more smoke and pollution of the outside air. A proper
operating chimney will allow the user to enjoy peak performance at all burn operating levels from low to high.
Blaze King therefore recommends vertical installations with a minimum length of 15’ from stove top to chimney
cap. In all freestanding stove installations, use double wall stove pipe from the stove top to the ceiling support
box. The use of double wall stove pipe does allow for reduced clearances, however most importantly, it helps to
keep the chimney warm and improve draft.
For wall exits, the same suggestion applies. With the addition of the recommendation to use two 45 degree
elbows rather than a single 90 degree elbow. The use of two 45 degree elbows will allow for both a smoother
transition to the exterior chimney and will also shorten the horizontal run to the outside chimney. A minimum
36” rise is recommended prior to any elbows being used. When possible, outside chimney systems should be
isolated from direct exposure to winter weather by building a chase around the chimney, observing all clearances
as specified by the venting manufacturer. Doing so will help to keep the chimney warmer and improve draft.
OM-BRII90 E V1.04 wo768
August 25, 2015
BRII/90
Page 14
INSTALLATION INSTRUCTIONS cont.
VENTING SYSTEMS
The venting system consists of a chimney connector and a chimney. These get extremely hot during use.
Temperatures inside the chimney may exceed 2000 degrees in the event of a creosote fire. To protect against the
possibility of a house fire, the chimney connector and chimney must be properly installed and maintained. A
listed thimble must be used when a connection is made through a combustible wall to a chimney. A chimney
support package must be used when a connection is made through the ceiling to a listed prefabricated chimney.
These accessories are absolutely necessary to provide safe clearances to combustible wall and ceiling material.
This stove may be connected to a lined masonry chimney or a listed factory built chimney suitable for use with
solid fuels and conforming to, ULC629 in Canada or UL-103HT in the USA. Do not connect it to a chimney
serving another appliance. To do so will affect the safe operation of both appliances, and will void the stove
warranty. You must comply with the local authority having jurisdiction and/or in Canada, CSA installation
standard B365-M87.
The chimney connector must be 8” diameter, 24 MSG Black/Blue steel. Do not use aluminum or galvanized
steel. They cannot properly withstand the extreme temperatures of a wood fire. The chimney connector between
the stove and the chimney should be as short and direct as possible.
The chimney connector must be attached to either an approved masonry chimney or one of the listed factory
built chimneys suitable for use with solid wood fuel. All joints must be tight and fastened with sheet metal
screws.
THE CHIMNEY CONNECTOR IS TO BE USED ONLY WITHIN THE ROOM, BETWEEN THE STOVE
AND CEILING / WALL. NEVER USE A CHIMNEY CONNECTOR TO PASS THROUGH AN ATTIC
OR ROOF SPACE, CLOSET OR SIMILAR CONCEALED SPACE, OR A FLOOR, OR CEILING. AN
EFFECTIVE VAPOR BARRIER MUST BE MAINTAINED AT THE LOCATION WHERE THE CHIMNEY
OR COMPONENT PENETRATES TO THE EXTERIOR OF THE STRUCTURE. ALWAYS MAINTAIN
THE MINIMUM CLEARANCES TO COMBUSTIBLES AS REQUIRED BY THE APPLICABLE BUILDING
CODES.
OM-BRII90 E V1.04 wo768
August 25, 2015
BRII/90
Page 15
INSTALLATION INSTRUCTIONS cont.
CONNECTION TO A METAL PREFABRICATED CHIMNEY
When a metal prefabricated chimney is used, the manufacturer’s installation instructions must be followed
precisely. You must also purchase (from the same manufacturer) and install the ceiling support package or wall
pass through and “T” section package, fire stops (when needed), insulation shield, roof flashing, chimney cap,
etc. Maintain the proper clearance to the structure as recommended by the manufacturer. This clearance is
usually a minimum of 2 inches, although it may vary by manufacturer or for certain components.
There are basically two methods of metal chimney installation. One method is to install the chimney inside the
residence through the ceiling(s) and the roof. The other method is to install an exterior chimney that runs up
the outside of the residence (not recommended). If it is necessary to run the chimney outside, build an outside
chase around the chimney.
The chimney must be the required height above the roof or other obstruction for safety and for proper draft
operation. The requirement is that the chimney must be at least 3 feet higher than the highest point where it
passes through the roof and at least 2 feet higher than
the highest part of the roof or structure that is within
10 feet of the chimney, measured horizontally (Fig. 1).
The height requirement is necessary in the interest of
safety and does not necessarily assure proper flue draft.
Use a minimum total system height of 15 feet, measured
from the stove flue collar to the top of the chimney, not
including the chimney cap.
OM-BRII90 E V1.04 wo768
August 25, 2015
BRII/90
Page 16
INSTALLATION INSTRUCTIONS cont.
CONNECTION TO A MASONRY CHIMNEY
Masonry chimney***
Ensure that a masonry chimney meets the minimum standards
(NFPA) by having it inspected by a professional. Make sure there are
no cracks, loose mortar or other signs of deterioration and blockage.
Have the chimney cleaned before the stove is installed and operated.
When connecting the stove through a combustible wall to a masonry
chimney, special methods are needed.
In Canada, the wall cut away is to provide 18” clearance for the
connector. The resulting space must remain empty. A flush mounted
sheet metal cover may be used on one side only. If covers are to be
used on both sides, each cover must be mounted on noncombustible
spacers at least 1” clear of the wall.
***Blaze King recommends the use of a Stainless steel liner,
preferably insulated, inside a masonry chimney. This to maintain
proper draft and overall better operation of the unit.
Your local dealer or local jurisdiction can provide details of
approved methods of passing a chimney connector through
a combustible wall in your area. In USA, the National Fire
Protection Association has minimum standards to comply
with. In Canada , this type of installation must conform to
CAN/CSA-B365, Installation Code for Solid Fuel Burning
Appliances and Equipment.
OM-BRII90 E V1.04 wo768
August 25, 2015
BRII/90
Page 17
INSTALLATION INSTRUCTIONS cont.
MOBILE HOME (AND RESIDENTIAL ALCOVE INSTALLATIONS)
Use double wall listed pipe, side shields, and rear shield (See next page for kits and part numbers). Mobile home
installations also requires an outside air kit #Z1526. They are easiest to mount before the stove is installed.
See instructions packed with each kit. NOTE: UNDER NO CIRCUMSTANCES SHOULD THE FRESH
AIR TUBE EVER BE INSTALLED HIGHER THAN THE BOTTOM OF THE APPLIANCE FIREBOX
FLOOR
When a metal prefabricated chimney is used, the manufacturer’s installation instructions must be followed
precisely. You must also purchase (from the same manufacturer) and install the ceiling support package, fire
stops (when needed), insulation shield, roof flashing, chimney cap, etc. Maintain the proper clearance to the
structure as recommended by the manufacturer.
Chimney connector must be double wall close clearance type with either ULC629 or ULCS610 designation.
Single wall pipe is not allowed in Mobile Homes or in Alcove Installations. Insulated chimney components
must be a listed factory built chimney suitable for use with solid fuels and conforming to, ULC629 in Canada or
UL-103HT in the USA. For Mobile home, the chimney needs to be removable to allow for transportation of the
mobile home.
DO NOT INSTALL IN SLEEPING ROOM. THE STRUCTURAL INTEGRITY OF THE MOBILE
HOME FLOOR, WALL AND CEILING / ROOF MUST BE MAINTAINED.
In mobile home installations the stove must be
securely fastened to the floor using the lag bolts
provided in the outside air kit:
1. Position the stove on the floor protector so that
the minimum clearances are met.
2. Remove the back pedestal cover.
3. Drill down through the holes in the base of the
stove, penetrating both the floor protector and
the floor of the home.
4. Place two lag screws through the holes and fasten
them securely to the floor of the structure. (Make
sure the stove cannot shift or move.)
ALSO, a #8 ground wire must be attached to the
stove and an appropriate ground.
OM-BRII90 E V1.04 wo768
August 25, 2015
BRII/90
Page 18
INSTALLATION INSTRUCTIONS cont.
OPTIONAL ACCESSORIES
Outside air kit, side shields, and rear shield are optional accessories, but are required for the
following installations:
MOBILE HOME INSTALLATION — Requires outside air kit, side shields, and rear shield.
RESIDENTIAL ALCOVE — Requires outside air kit, side shields, and rear shield.
REAR SHIELD KIT (ZRSBRII)
REQUIRED FOR:
MOBILE HOME, any installation
RESIDENTIAL ALCOVE
INSTALLATION : The rear shield goes across the back of the stove. Remove the four 1/4” x 1/2”
hex bolts. Place the rear shield into position so that the notch on the shield wraps the lip on the
stove top. Insert and tighten the four 1/4” X 2-1/2" hex bolts provided.
FAN KIT (P/N Z1514)
Includes ZRSBRII rear shield
NOTE: Fan kit should be installed before the stove is placed into position
INSTALLATION: See instructions included with fan kit.
ELECTRICAL CONNECTION:
Your Blaze King fan kit is equipped with a three-prong (grounded) plug to decrease shock hazard.
THIS PLUG SHOULD BE INSERTED DIRECTLY INTO A PROPERLY-GROUNDED, THREEHOLE RECEPTACLE. DO NOT CUT OR REMOVE THE GROUNDING PRONG FROM THIS
PLUG. Do not route the power cord in front or under the stove.
OUTSIDE AIR KIT (P/N Z1526)
REQUIRED FOR:
MOBILE HOME (any installation)
The outside air inlet hose is a flexible tube to bring outside air for combustion into the stove from
outside the residence, through the wall or up through the floor. The flexible tube will allow some
adjustment over or around floor joists or plumbing. DO NOT CHANGE THE STRUCTURAL
INTEGRITY OF THE FLOOR. This air hose must be kept open at all times to provide outside air
for combustion.
INSTALLATION
See instructions included with the outside air kit. Tools needed: 1/4" or 3/8" drill motor, saber
saw, saber saw wood & metal blades, 5/16" nut driver or wrench, 7/16" wrench, Small tube of hiheat silicone.
OM-BRII90 E V1.04 wo768
August 25, 2015
BRII/90
Page 19
INSTALLATION INSTRUCTIONS cont.
DOOR INSTALLATION AND CHANGE-OUT
To install the door upon stove installation or to change it out, follow these steps:
DOOR IS HEAVY, PLEASE HOLD FIRMLY.
INSTALLATION
1. Insert the top of door hinge rod into the top hinge hole on the firebox.
2. Lower door onto bottom hinge hole.
NOTE: If your door has a gold or silver plating on it , please follow the instructions
on the PLATED DOOR & TRIM CARE card found in the manual pack.
OM-BRII90 E V1.04 wo768
August 25, 2015
BRII/90
Page 20
OPERATING INSTRUCTIONS
YOUR FIRST FIRE!
The following pages contain information on the major components and operation of your heater. Please take
time to read about them as it will give you a better understanding of how your stove works. This understanding
will help you to operate your stove properly thus will extend the life of your stove and allow you to get the
highest efficiencies from your heater.
SELECTING WOOD
•
•
•
THIS APPLIANCE IS DESIGNED TO BURN NATURAL WOOD ONLY. DO NOT BURN
TREATED WOOD, COAL, CHARCOAL, COLORED PAPER, CARDBOARD, SOLVENTS OR
GARBAGE.
HIGHER EFFICIENCIES AND LOWER EMISSIONS WILL GENERALLY RESULT WHEN
BURNING AIR DRIED SEASONED WOODS, AS COMPARED TO WET, GREEN OR
FRESHLY CUT WOODS.
BURNING WET UNSEASONED WOOD CAN CAUSE EXCESSIVE CREOSOTE
ACCUMULATION. WHEN IGNITED IT CAN CAUSE A CHIMNEY FIRE THAT MAY RESULT
IN A SERIOUS HOUSE FIRE.
Use dry seasoned wood, split and stacked and protected from rain for at least 24 months with a moisture content
of 20% or lower. It takes a great deal of energy to evaporate the moisture contained in green wood and that
energy will not be heating your house. Also, green or wet wood will greatly increase creosote problems. The
only accurate method to determine moisture content in wood is to use a moisture meter.
Never burn salt-water driftwood. It is very corrosive and will damage the firebox. Burning salty wood also voids
the warranty.
This controlled combustion firebox has been designed for high efficiency and long burn times. The proper time
to add more wood is when the last charge has been reduced to a glowing charcoal bed. There will be very little
smoke at this stage in the burn cycle.
Both hardwood and softwood burn equally well in this appliance but hardwood, which is more dense, will weigh
more per cord and burn a little slower and longer.
Firewood should be split and stacked in a manner that air can get to all parts of it and covered in early spring to
be ready for burning that fall.
The only accurate way to determine wood moisture is to purchase a moisture meter.
•
NEVER START A FIRE UNLESS ALL BRICKS ARE CORRECTLY PLACED INSIDE THE
FIREBOX. CHECK THE INSTALLATION INSTRUCTIONS CAREFULLY.
OM-BRII90 E V1.04 wo768
August 25, 2015
BRII/90
Page 21
OPERATING INSTRUCTIONS cont.
HOW TO USE MOISTURE METERS
1. Take a random selection of around 3-4 logs per
cubic yard or cubic meter.
2. Split each log down the middle.
3. In the center of log push pins of meter along
grain - three measurements are taken on the
freshly split surface: 2” or 5 cm in from each
end of the log and in the middle of the split
surface with sufficient contact (see figure).
4. Do this to all the logs and take an average of
the readings (this will be only an approximate
indication but a good guide).
2” / 5 cm
2” / 5 cm
EFFICIENCY
Efficiency was determined using the method outlined in B415.1-10 test method. It is represented by the Higher
Heating Value (HHV) as the fuel used during testing contains between 19% - 25% water moisture included in
the total calculated fuel weight. (Other test methods such as LHV or Low Heating Value, does not take the water
moisture into account).
Annual Fuel Utilization Efficiency (AFUE) attempts to represent the actual, season long, average efficiency of
an appliance. HHV is the actual, calculated average efficiency obtained under test conditions. Using correctly
seasoned wood is important when trying to gain efficiency. The more seasoned (dry) the wood, the higher the
efficiency (less energy wasted on eliminating moisture during combustion). Operating your Blaze King at lower
settings will result in higher efficiencies as the fuel will undergo a more complete combustion. For maximum
efficiency, the appliance should be installed in a location that provides adequate intake/combustion air as well as
a location that will allow for the straightest run of optimal chimney length to establish necessary draft .
OM-BRII90 E V1.04 wo768
August 25, 2015
BRII/90
Page 22
OPERATING INSTRUCTIONS cont.
LIGHTING THE FIRE
NOTE: As you heat up the stove for the first time, the paint will go through a curing
Low
High
process and will give off an odor. To minimize the inconvenience, burn the stove on low
for several hours. It is advisable to open a door or window until the odor dissipates. You
may also notice a change in color as the paint cures, this is normal and will appear uniform
Draft Control
after subsequent firings.
1. DO NOT USE A GRATE. BUILD THE FIRE DIRECTLY ON THE BRICK IN THE BOTTOM OF THE
STOVE.
2. Set the draft control to HIGH (maximum) position and turn the fan OFF (if applicable).
3. Open the loading door.
4. Place 10 balls of non-glossy paper towards the front of the bottom of the firebox, or use a Blaze King fire starter
puck, then stack 20 pieces of kindling on top of the paper in a crisscross fashion (leaving air gaps in between
sticks).
5. Light the fire and allow it to get a good start while leaving the loading door cracked open (approximately 3 to 5
minutes). DO NOT LEAVE THE STOVE UNATTENDED.
6. Once the kindling is fully on fire, place two or three medium size logs onto the fire. Keeping the loading
door unlatched, allow the logs to catch fire (approximately 5 minutes). DO NOT LEAVE THE STOVE
UNATTENDED. KEEP COALS AWAY FROM THE FRONT OF THE STARTER MANIFOLD (small air
intake beneath the loading door)
7. Once the logs are burning, latch the loading door shut.
8. When nearly all of the wood in the firebox is fully burning, finish loading the stove. Lay the wood as far back in
the stove as possible.
9. Let the fire burn with the draft control on HIGH for 20-30 minutes, or until the fire is well established. At that
point set the draft control to the desired setting. It is good burning practice to burn the stove on HIGH for 20 to
30 minutes after every refuelling, this will help to condition the wood load for optimum combustion. During the
start-up of a cold stove, a HIGH fire must be maintained for at least 20-30 minutes. This ensures that the stove and
fuel are all stabilized at proper operating temperatures. If the fire is allowed to die down immediately (draft control
set to LOW too soon), it may go out.
10. The fan (if applicable) can be turned on when the stove is hot or after the initial warm up period of 20-30 minutes.
Probably the least understood requirement in maintaining a good fire is that of establishing a good base of coals. A good
bed of hot coals will maintain a more even temperature as well as getting the new load of wood started easily.
RELOADING PROCEDURE
1. Have your next load of wood ready before beginning. Turn the draft control to HIGH and the fan OFF(if applicable).
Wait 2 minutes for the air flow to stabilize.
2. Unlatch the loading door and open just a crack to allow the ambient room air to be introduced to the firebox, this may
take a few seconds to stabilize.
3. Slowly open the loading door and proceed to reload the firebox. If you experience excessive smoke spillage, slightly
close the loading door to re-establish a draft through the chimney.
4. Once loaded, latch the loading door shut. Let the fire burn on the HIGH draft control setting for 20 to 30 minutes OR
until the fire is well established. At that point, slide the draft control to the desired setting.
5. Should you burn the stove on a very LOW setting for extended periods of time, you will begin to see creosote deposits
forming on the glass door. To remove these deposits, run the stove on HIGH for approximately 30 minutes. The
HIGH setting will burn off most of the deposits.
As every pile of wood is different you will learn, over time, which settings are necessary to achieve the optimal fire. This
will be based on the type of wood, installation, weather conditions and the desired room temperature.
OM-BRII90 E V1.04 wo768
August 25, 2015
BRII/90
Page 23
OPERATING INSTRUCTIONS cont.
FAN OPERATION
If you have the fan system installed, the fan should be off for 20 - 30 minutes until the stove reaches normal
operating temperatures. The fan speed adjustment should match the draft control setting, i.e. if your stove is set
at medium then your fan should also be set at medium, low—low, high—high etc.. We recommend the use of
an optional fan system on all our wood stoves. The fan system recirculates the room air over the hot surfaces of
your stove and helps spread this super heated air around your home.
WOOD BURNING IN THE SHOULDER SEASON
There are things to consider if you decide to light a fire in the spring and fall or when the outside temperature is
milder, perhaps 55°F to 70°F (13°C to 21°C).
As you light the fire, with the loading door open, you may notice spillage, this is when a small amount of smoke
comes back into the living space. When your fire begins to warm the chimney and the draft improves, spillage
is greatly reduced. After a short period of time you can slide the draft control to a LOW setting and maintain a
comfortable temperature in your home.
In reducing the draft control setting you have also reduced the flue temperatures and your chimney begins to
cool down. At this time the amount of draft is also decreasing and spillage may occur. The differences between
the flue temperature and the outdoor air temperatures causes your chimney to draw and vent the flue gasses
to the outside. This air movement, sometimes referred to as Stack Effect, is also influenced by air density and
moisture differences. Small temperature differences produce less draw in your chimney system than large
temperature differences.
General Rules for burning in the shoulder season:
• Run your stove on high for 30 minutes after start up and reloading.
• Slowly slide the air control down to the desired heat setting.
• If your stove is producing too much heat, start to build smaller hotter fires.
OM-BRII90 E V1.04 wo768
August 25, 2015
BRII/90
Page 24
MAINTENANCE
RUN-AWAY OR CHIMNEY FIRE
A CHIMNEY FIRE CAN PERMANENTLY DAMAGE YOUR CHIMNEY SYSTEM. THIS DAMAGE CAN
ONLY BE REPAIRED BY REPLACING THE DAMAGED COMPONENT PARTS. CHIMNEY FIRE
DAMAGE IS NOT COVERED BY THE LIMITED WARRANTY.
CAUSES:
1. Using incorrect fuel, or small fuel pieces which would normally be used as kindling.
2. Leaving the door ajar too long and creating extreme temperatures as the air rushes in the open door.
3. Improperly installed or worn gaskets.
4. Creosote build up in the chimney.
SOLUTIONS:
1. Do not burn treated or processed wood, coal, charcoal, colored paper or cardboard.
2. Be careful not to over fire the appliance by leaving the door open too long after the initial start-up.
3. Replace worn, dried out (inflexible) gaskets.
4. Have your chimney cleaned regularly.
WHAT TO DO IF A RUN-AWAY OR CHIMNEY FIRE STARTS:
1. Slide the draft control to LOW (lowest position), and make sure firebox is closed tightly.
2. Call the local fire department.
3. Examine the chimney, attic and roof of the house, to see if any part has become hot enough to catch fire.
If necessary spray with a fire extinguisher or water from a garden hose.
4. Do not operate the appliance again until you are certain the chimney has not been damaged.
CREOSOTE FORMATION AND REMOVAL
When wood is burned slowly, it produces tar and other organic vapors which combine with expelled moisture
to form creosote. These vapors condense in the relatively cooler chimney flue of a slow burning fire and when
ignited, make an extremely hot fire. Check your chimney for creosote and soot build-up daily, until a safe
frequency for cleaning is established. The chimney connector and chimney should be inspected regularly during
the heating season to determine if a creosote build up has occurred. Be aware that the hotter the fire, the less
creosote is deposited, and weekly cleaning might be necessary in mild weather, even though substantially longer
period without cleaning may be sufficient in colder months.
If accumulation is excessive, clean the chimney. You may want to call a professional chimney sweep to clean it.
Both the chimney and the appliance have to be cleaned at least once a year or as often as necessary.
Have a clearly understood plan to handle a chimney fire.
OM-BRII90 E V1.04 wo768
August 25, 2015
BRII/90
Page 25
MAINTENANCE cont.
CHIMNEY MAINTENANCE
The most efficient method to sweep the chimney is using a hard brush. Brush downwards so soot and creosote
residues will come off the inner surface and fall to the bottom of the chimney where they can be removed easily.
The chimney must be checked regularly and if creosote has accumulated, it must be removed without delay.
Cleaning on a regular basis should be sufficient during the coldest months.
Smoke Flue Inspection:
1.
2.
3.
4.
The chimney should be inspected regularly during the heating season.
If possible, the chimney should be dismantled and cleaned.
The chimney should be inspected for possible damage.
If it is in good condition, put the chimney back in place; otherwise, it must be replaced.
FIRE EXTINGUISHERS AND SMOKE DETECTORS
All homes with a solid fuel burning appliance should have at least one fire extinguisher in a central location,
known to all, and at least one smoke detector in the room containing the appliance. If it sounds an alarm,
correct the cause but do not de-activate or relocate the smoke detector.
ASH REMOVAL
This appliance is required to be cleaned frequently because soot, creosote and ash may accumulate. Wait
until the stove is fully cooled off before the removal of ashes. ALWAYS REMOVE THE ASH BUCKET
IMMEDIATELY AFTER FILLING. Ashes should be removed any time they come within one inch of the door
opening. It is not necessary or advisable to completely remove all of the ashes when cleaning this stove. Wood
burns best in a bed of ashes 1/2” thick. Ashes should be placed in a metal container with a tight fitting lid. The
closed container of ashes should be placed on a noncombustible floor or on the ground (outside), well away
from all combustible materials, pending final disposal. If the ashes are disposed of by burial in soil or otherwise
locally dispersed, they should be retained in the closed container until all cinders have thoroughly cooled. Other
waste shall not be placed in this container.
NEVER STORE HOT ASHES IN A GARAGE OR BASEMENT. HOT ASHES WILL GENERATE
CARBON MONOXIDE AND / OR FLAMMABLE GASES. THESE GASES MAY CAUSE
SUFFOCATION AND POSSIBLE DEATH.
OM-BRII90 E V1.04 wo768
August 25, 2015
BRII/90
Page 26
MAINTENANCE cont.
LOADING DOOR GASKET INSPECTION
Inspect the door gasket for physical deterioration, missing sections or obvious leakage. The stove front should
make a groove in the gasket material - one side of the groove (toward the inside) will often be dark or black, and
the other side (toward the outside) should be light or white. Dark smudges on the outside of the groove may
indicate a air leak. If the groove is very shallow or missing, or if there is a heavy ash or creosote deposit along
the bottom edge of the gasket, it may need to be replaced. Frayed or broken gasket material, or a gasket that is
hard and unyielding, will also indicate need for replacement. Any time a piece of gasket is missing or is broken
anywhere, the entire gasket must be replaced.
To check the gasket further, wait until the stove is cooled and insert a piece of paper (a dollar bill will work) into
the door opening and close and latch the door. Obvious resistance should be felt when pulling the paper out
Repeat this check several times around the perimeter of the door.
LOADING DOOR GASKET REPLACEMENT
BLAZE KING RECOMMENDS YOUR DEALER PERFORM THIS TASK
1. If the door gasket is to be replaced, be sure you have Blaze King 7/8” fiber glass gasket ready to re-install,
as well as high temperature adhesive. See your Blaze King dealer.
2. Be sure the fire is out and the stove has cooled down. The door should be removed by lifting up and out,
off of the hinge pins. Then lay the door flat.
3. With a pair of pliers, pull the old door gasket out of the channel and dispose of it.
4. Thoroughly clean out the channel so the new silicone adhesive will adhere and the gasket will fit
smoothly.
5. Dry fit the new gasket first to ensure proper fit. Do not stretch or cut the gasket. Distribute the gasket
evenly around the frame.
6. Run a small bead of a high temperature silicone adhesive along the center of the channel. DO NOT
USE HOUSEHOLD SILICONE CAULKING. High temperature silicone may be obtained from wood
stove dealer.
7. Start the new gasket in the lower right corner. Do not stretch or cut the gasket. Distribute the gasket
evenly around the frame.
8. Allow the adhesive to dry before closing the loading door. The loading door tension may need to be
adjusted, see “LOADING DOOR TENSION ADJUSTMENT” on page 41.
9. Check the fit of the door gasket. Insert a narrow strip of paper into the door opening and close and latch
the door. Obvious resistance should be felt when pulling the paper out. Repeat this check several times
around the perimeter of the door. If no resistance is felt, adjust door latch catch, see “LOADING DOOR
TENSION ADJUSTMENT” on page 28.
10. A tight sealing door extends the burn times.
OM-BRII90 E V1.04 wo768
August 25, 2015
BRII/90
Page 27
MAINTENANCE cont.
DOOR GLASS GASKET INSPECTION
When the stove is cold, hold the glass by placing the palm of each hand on either side of the glass. Press firmly
and try to move the glass. If the glass moves the door glass gasket may need to be replaced. Inspect the door
glass gasket. If the gasket is frayed or missing sections replace the gasket.
DOOR GLASS GASKET REPLACEMENT
BLAZE KING RECOMMENDS YOUR DEALER PERFORM THIS TASK
1. You will require Blaze King glass gasket and Blaze King door gasket. Please see your Blaze King dealer.
2. Remove the old glass gasket.
3. Starting at the top right corner, carefully wrap the gasket around the edges, pressing firmly onto the
sides of the glass with the gasket centered on the edge.
Finish the wrapping with a 1/2” overlap. Ensure
the thickness of the gasket remains consistent and
uniform.
4. Install the glass frame with original fasteners. Ensure
the glass is parallel to the frame and tighten the
fasteners evenly.
5. Follow steps on page 26, “LOADING DOOR
GASKET REPLACEMENT”.
DOOR GLASS, CLEANING
The best way to keep the glass clean is to leave the stove on high burn for a period of time after each reloading
The moisture which is driven from a new load of wood contributes much of the creosote on the inside of the
glass. Removing that moisture at the beginning of the burn cycle helps to keep the glass clean. Leaving the air
control on a higher setting for 30 minutes to an hour before turning to low for an overnight burn will also help.
Heavier deposits may require hand cleaning. Manual glass cleaning should be done when the stove and glass are
cool. DO NOT CLEAN THE GLASS WHILE IT IS HOT. WARNING: Do not use abrasive cleaners
to clean the glass. Use a soft cloth. After using any cleaner, thoroughly rinse the glass with water to remove
any deposits left by the cleaner. Failure to remove all traces of glass cleaner will result in the glass cleaner residue
baking on. This residue may be very difficult to remove.
OM-BRII90 E V1.04 wo768
August 25, 2015
BRII/90
Page 28
MAINTENANCE cont.
LOADING DOOR TENSION ADJUSTMENT
To tighten the door seal:
1. Open the loading door.
2. Rotate the handle counter-clockwise one rotation
(Fig. A).
3. Repeat paper test. (see “LOADING DOOR
GASKET INSPECTION” on page 37)
4. Repeat steps 1-3 if necessary.
To lossen the door seal:
1. Open the loading door.
2. Rotate the handle clockwise one rotation (Fig. B).
3. Repeat paper test. (see “LOADING DOOR
GASKET INSPECTION” on page 37)
4. Repeat steps 1-3 if necessary.
DO NOT OPERATE THIS WOOD STOVE
IF THE DOOR GASKET IS MISSING OR
DAMAGED. DANGEROUS OVER FIRING
CAN OCCUR WHICH CAN DAMAGE THE
APPLIANCE OR IGNITE CREOSOTE IN THE
CHIMNEY, POSSIBLY CAUSING A HOUSE
FIRE. IF ANY PART OF THE WOODSTOVE OR
FLUE SYSTEM IS GLOWING THE STOVE IS
BEING OVER FIRED.
OM-BRII90 E V1.04 wo768
August 25, 2015
BRII/90
Page 29
MAINTENANCE cont.
BAFFLE REPLACEMENT
The baffle is the part of the stove that receives the most heat. For this reason, as well as for chimney cleaning ease, it was
designed for easy removal. Remove the two allen head cap screws and washers from each side of baffle support plates (Fig.
A) to allow the baffle to slide forward and out (Fig. B). The baffle may be damaged by over firing and burning improper
fuels, incorrect baffle damage will not covered by warranty. To order replacement baffles please call your dealer with the
model and serial number of your stove.
CHIMNEY DRAFTS
Draft is the force which moves air into the appliance and up through the chimney. The amount of draft in your chimney
depends on the length of the chimney, local geography, nearby obstructions and other factors. Too much draft may cause
excessive temperatures in the appliance. Inadequate draft may cause back puffing into the room and ‘plugging’ of the
chimney.
Inadequate draft will cause the appliance to leak smoke into the room through appliance and chimney connector joints.
An uncontrollable burn or excessive temperature indicates excessive draft.
If you suspect a draft problem in an existing chimney, determine the draft by using a water manometer (or digital
draft gauge). The draft should be measured with the stove at medium burn and high burn. After the measurement
is completed, fill any holes that were made in the chimney connector by using a sheet metal screw of proper size.
Recommended draft is .02 -.03 in. w.c. at medium fire and .05 in. on high burn. Too little draft results in a sluggish fire
and smoke spillage when the stove door is opened. Too much draft (over 0.06 in. w.c. on high burn) makes it unsafe to
operate the stove and will void manufacturers warranty.
OPTIONAL FAN ASSEMBLY
Routine maintenance of the OPTIONAL Fan Assembly on the back of the stove is not required. However, should it
become necessary to replace an individual fan or rheostat, contact your local dealer.
OM-BRII90 E V1.04 wo768
August 25, 2015
BRII/90
Page 30
TROUBLESHOOTING
Your Blaze King is designed to allow a wide selection of heat output levels. If you begin to lose control of the amount of heat the stove
is emitting, determine the cause early so that major problems may be avoided.
The five major needs of a well-controlled fire are:
1. Knowledgeable operator.
2. Adequate air supply.
3. Firewood of good quality and proper size.
4. Clean chimney, properly sized and installed.
5. Door gasket tight and firm.
Considering all of the above, number one is the most important for safe and efficient operation of any woodstove. Please study the
operation instructions carefully. Consult your BLAZE KING dealer or call the Customer Service Department at Blaze King in the
U.S.A. at 509-522-2730 or in Canada at 250-493-7444 if you have any questions not answered in this manual.
All of the five above mentioned needs are interrelated. A deficiency in any one will affect all of the others. If you encounter a problem,
determine the source of the problem and then follow-up by checking the other needs as possible contributing factors.
PROBLEM: Chimney Fire
CAUSE
Act immediately regardless of cause
SOLUTION
Slide the draft control to LOW, check loading door to be sure it is
tightly closed.
Call Fire Department.
After the fire is out, have your chimney and flue connector inspected by a certified chimney sweep. A damaged masonry chimney
should be repaired or rebuilt. A prefabricated chimney (factory built) that is damaged should be replaced. Any damage to the flue
connector should be corrected before the system is used again.
Possible causes of a chimney fire, and remedies for those causes, can be found further in this section: “Excessive Creosote Formation”,
and “Spots of Creosote Accumulation in Chimney or Flue Connector”.
PROBLEM: Not enough heat.
CAUSE
Green or wet wood.
Not enough fuel in stove.
SOLUTION
Use seasoned wood. Don’t be afraid to FULLY load the stove.
Poor draft caused by an oversize flue
Measure draft with Manometer. See “CHIMNEY DRAFTS”
Consult your Blaze King dealer or a chimney sweep.
Strong, gusting winds causing downdraft in
chimney
Install wind-resistant chimney cap. Directional caps may not stay
freely rotating. If you have a directional cap, check it frequently.
Tightly sealed house, inadequate air supply.
Slightly open a window, near the stove or install an outside air kit.
Reloading too much wood on top of too few coals.
Allow a larger bed of coals to build up.
PROBLEM: Too much heat.
CAUSE
Draft control set too high.
SOLUTION
Slide draft control lower.
Loading door gasket leaking, admitting excess air
into firebox.
Replace door gasket and/or adjust door. See “GASKET
INSPECTION”
Excessive draft in the chimney.
Measure draft with a Manometer. See “DRAFTS”. Consult your
Blaze King dealer or a chimney sweep. Install a cap.
Wood is too small.
Use larger pieces.
OM-BRII90 E V1.04 wo768
August 25, 2015
BRII/90
Page 31
TROUBLESHOOTING cont.
PROBLEM: One or both fans will not run, or there is no adjustment for fan speed.
CAUSE
Fan mounted improperly.
SOLUTION
Check that fan blade’s not touch edges of housing.
Fan speed control.
Consult your Blaze King dealer for replacement.
PROBLEM: Fans minimum speed too fast or maximum speed too slow.
CAUSE
Fan speed control out of adjustment.
SOLUTION
Consult your Blaze King Dealer.
PROBLEM: Excessive creosote formation in chimney and chimney Connector.
CAUSE
Wood too green or wet.
SOLUTION
Use seasoned wood. Use a moisture meter to confirm.
Poor draft caused by an oversize or short flue, etc.
Measure draft with Manometer. See “DRAFTS”. Consult your
Blaze King dealer or a chimney sweep.
Chimney too cold or poorly insulated.
Upgrade chimney system. Consult your Blaze King dealer or a
chimney sweep.
PROBLEM: Spots of creosote accumulation in chimney or chimney connector.
CAUSE
Air leaks in chimney or chimney connector.
SOLUTION
Inspect chimney and / or chimney connector. Repair or replace
as necessary. Check to be sure that the chimney connector is
installed correctly.
CAUTION: a leaking chimney connector is a fire hazard and demands immediate attention.
Poor draft caused by an oversize flue, single wall
pipe, to many elbows, etc.
Measure draft with Manometer. See “DRAFTS”. Consult your
Blaze King dealer or a chimney sweep.
PROBLEM: Door glass quickly becomes coated with creosote.
CAUSE
LOW draft control setting.
SOLUTION
Slide the draft control to HIGH during the first 20-30 minutes or
until the fire is well established after each reloading.
Poor draft caused by an oversize or short flue, etc.
Measure draft with manometer. See “DRAFTS”. Consult your
Blaze King dealer or a chimney sweep.
Obstruction in chimney or cap screen.
Remove obstruction. Clean chimney and/or cap screen.
Strong, gusting winds causing downdraft in
chimney.
Install wind-resistant chimney cap.
Tightly sealed house, inadequate air supply.
Open a window slightly, near the stove.
Burning poorly seasoned wet wood, or wood with
high pitch content.
Use seasoned wood with low pitch content, such as some types of
pine.
PROBLEM: Smoke spills from door opening when loading fuel
CAUSE
Chimney too cold.
SOLUTION
Make certain double wall stove pipe is used in installation.
Not enough vertical rise.
Make certain a minimum vertical rise of 36” is observed prior to
elbows. Use two 45 elbows instead of 90 elbow.
Chimney not drafting.
Slide draft control to HIGH setting and wait 5-10 minutes to
increase chimney or flue temperature.
OM-BRII90 E V1.04 wo768
August 25, 2015
BRII/90
Page 32
REPLACEMENT PARTS cont.
ITEM
NO.
1
2
3
4
OM-BRII90 E V1.04 wo768
PART
NUMBER
0186A-6ft
0254AS-6ft
0730
ZBR518
ZBR518P-C
DESCRIPTION
QTY.
Gasket 7/8” hard rope for Briarwood
1/8” window gasket
Robax Glass 10 5/8” x 21 5/8”
Door without glass
Door with glass, no handle
1
1
1
1
1
August 25, 2015
BRII/90
Page 33
REPLACEMENT PARTS cont.
Briarwood Brick Layout
OM-BRII90 E V1.04 wo768
,7(0
12
3$57180%(5
47<
$6L]H%ULFN
6,6L]H%ULFN
<6L]H%ULFN
=6L]H%ULFN
August 25, 2015
BRII/90
Page 34
WARRANTY
BLAZE KING WOOD LIMITED WARRANTY
Blaze King and Valley Comfort’s respective brands extend the following warranty for wood fired
appliances purchased from an authorized Blaze King / Valley Comfort dealer and installed in the
United States of America or Canada. Warranty starts with date of purchase by the original owner
(End User) except as noted for replacement parts.
Components
Covered
Warranty Period
Parts
5 Years
1 Year
Labor
Wood
1 Year
X
All parts, materials and surface
finishes (flaking and peeling) Subject
to Conditions, Exclusion, and
Limitations listed.
2 Years
X
Fan assemblies and motors,
thermal sensors, door handle metal
components.
X
Firebox & Heat Exchanger
X
Other Replacement Parts
2 Years
See Conditions, Exclusions, and Limitations
OM-BRII90 E V1.04 wo768
August 25, 2015
BRII/90
Page 35
WARRANTY cont.
Blaze King Wood Limited 5 Year Warranty
Blaze King is the manufacturer of the Blaze King line of heating products. At Blaze King, our commitment to the highest
level of quality and customer service is the most important thing we do. Each Blaze King stove is built on a tradition of
using only the finest materials and is backed by our limited warranty to the original purchaser. With Blaze King, you’re not
just buying a stove; you’re buying a company with years of unequalled performance and quality.
Limited (5) Year Warranty:
Under this warranty, Blaze King covers the stove body and accessories against defects in materials and workmanship, for
part repair or replacement for the first five (5) years *** to the original purchaser. This Warranty covers: All Steel firebox
components against defects in material and workmanship. Please see the exclusions and limitation section below as
certain restrictions and exclusions apply this warranty.
Limited Two (2) Year Warranty:
Under this warranty, Blaze King covers, fan assemblies , modular thermostat and door handle steel components against
defects in materials and workmanship, for part repair or replacement and limited labor for the first two (2) years to the
original purchaser. Please see the exclusions and limitation section below as certain restrictions and exclusions apply to
this warranty.
Limited One (1) Year Warranty:
Under this warranty, Blaze King covers all parts and materials against defects in materials and workmanship including
exterior paint finishes, for part repair or replacement and limited labor for the first year to the original purchaser. Please
see the exclusions and limitation section below as certain restrictions and exclusions apply to this warranty.
How the Warranty Works
1. All warranties by the manufacturer are set herein and no claim shall be made against the manufacturer on any oral
warranty or representation. All claims under this Limited Warranty must be made in writing by your dealer.
2. Any stove or part thereof that is repaired or replaced during the Limited Warranty period will be warranted under the
3.
4.
5.
6.
terms of the Limited Warranty for a period not exceeding the remaining term of the original Limited Warranty or six (6)
months, whichever is longer.
For any part or parts of this stove, which in our judgment show evidence of defects, Blaze King reserves the option
to repair or to replace the defective part(s) through an accredited distributor or agent, provided the defective part is
returned to the distributor or agent, transportation prepaid, if requested.
If you discover a problem that you think may be covered by the Limited Warranty, you MUST REPORT it to your Blaze
King dealer WITHIN 30 DAYS from the date the problem was first detected, giving them proof of purchase and the
date of purchase. The dealer will investigate the problem and work with Blaze King to determine whether the problem:
a) Is covered by the Limited Warranty or
b) Can be fixed in your home or does the product need to be returned to Blaze King for repair.
If Blaze King determines that the stove needs to be returned to Blaze King for repair, the customer has the
responsibility and the expense of removing it from their home and shipping it to Blaze King. If the problem is covered
by the Warranty, Blaze King will repair or replace the item at their discretion and the customer will be responsible for
return shipping and re-installation in their home.
If the problem is not covered by the Limited Warranty, the customer will be responsible for all repair costs, as well as
all storage, shipping and the cost of removing and re-installing the stove.
If you are not satisfied with the service provided by the Blaze King dealer, write to Blaze King at the address listed on
the last page of the Owner’s Manual. Include a copy of the original purchase invoice and a description of the problem.
OM-BRII90 E V1.04 wo768
August 25, 2015
BRII/90
Page 36
WARRANTY cont.
Exclusions and Limitations:
1. This Warranty does not cover tarnish, discoloration or wear on the plated surfaces Painted finishes will change color
after initial firing and will continue to change through the lifetime of the stove. This is normal occurrence for all high
temperature coatings.
2. This Warranty does not cover gasket material or firebrick.
3. Blaze King strongly recommends installation by a certified installer. Failure to comply may adversely affect coverage
under the terms of this warranty. This Limited Warranty covers defects in materials and workmanship only if the
product has been installed in accordance with local building and fire codes; in their absence refer to the owner’s
manual. If the product is damaged or broken as a result of any alteration, wilful abuse, mishandling, accident, neglect,
or misuse of the product, the Limited Warranty does not apply.
4. The stove must be operated and maintained at all times in accordance with the instructions in the Owner’s Manual.
If the unit shows signs of neglect or misuse, it is not covered under the terms of this Warranty policy. Performance
problems due to operator error will not be covered by the Limited Warranty policy.
Some minor expansion, contraction, or movement of certain parts and resulting noise, is normal and not a defect and,
therefore, is not covered under this Limited Warranty.
5. Misuse includes over-firing. Over-firing can be identified later by warped plates and paint pigment being burnt off.
Over-firing this appliance can cause serious damage and will nullify the Limited Warranty.
6. The Limited Warranty will cover glass thermal breakage only and will not cover misuse of the stove glass, including
but not limited to:
a) Glass that is struck, has surface contaminates or has had harsh or abrasive cleaners used on it.
b) If the door is slammed or is closed while wood in the firebox is protruding out the stove opening thus striking the
glass.
7. This warranty does not cover products made or provided by other manufacturers and used in conjunction with the
operation of this stove without prior authorization from Blaze King The use of such products may nullify the Limited
Warranty on this stove. If unsure as to the extent of this Limited Warranty, contact your authorized Blaze King dealer
before installation.
8. Blaze King will not be responsible for inadequate performance caused by environmental conditions.
9. The Limited Warranty does not cover installation and operational related problems such as use of downdrafts or
spillage caused by environmental conditions. Environmental conditions include but are not limited to nearby trees,
buildings, roof tops, wind, hills, mountains, inadequate venting or ventilation, excessive offsets, negative air pressures
or other influences caused by mechanical systems such as furnaces, fans, clothes dryers etc.
10. The Limited Warranty does not cover damage caused by burning salt-saturated wood, corrosive driftwood, chemically
treated wood or any fuel not recommended in the Owner’s Manual (use cord wood only).
11. The Limited Warranty is void if:
a) The stove has been operated in atmospheres contaminated by chlorine, fluorine or other damaging chemicals.
b) The stove is subject to submersion in water or prolonged periods of dampness or condensation.
c) Any damage to the unit, combustion chamber or other components due to water, or weather damage which is the
result of, but not limited to, improper chimney/venting installation.
d) Salt air in coastal areas or high humidity can be corrosive to the finish; these environmental conditions can cause
rusting. Damage caused by salt air or high humidity is not covered by the Limited Warranty.
12. Exclusions to the Limited Warranty include: injury, loss of use, damage, failure to function due to accident, negligence,
misuse, improper installation, alteration or adjustment of the manufacturer’s settings of components, lack of proper
and regular maintenance, alteration, or act of God.
13. The Limited Warranty does not cover damage caused to the stove while in transit. If this occurs, do not operate the
stove and contact your courier and/or dealer.
14. The Limited Warranty does not extend to or include paint, door or glass gaskets or firebricks damage caused by
normal wear and tear, such as paint discoloration or chipping, worn or torn gaskets, chipped or cracked firebrick, etc.
15. The Limited Warranty does not include damage to the unit caused by abuse, improper installation, or modification of
the unit.
OM-BRII90 E V1.04 wo768
August 25, 2015
BRII/90
Page 37
WARRANTY cont.
16. Damage to plated surfaces caused by fingerprints, scratches, melted items, or other external scores and residues left
on the plated surfaces from the use of abrasive cleaners or polishes is not covered in this warranty.
17. Blaze King is free of liability for any damages caused by the stove, as well as inconvenience expenses and materials.
The Limited Warranty does not cover incidental or consequential damages.
18. The Limited Warranty does not cover any loss or damage incurred by the use or removal of any component or
19.
20.
21.
22.
23.
24.
25.
26.
27.
28.
29.
30.
31.
32.
33.
apparatus to or from the Blaze King stove without the express written permission of Blaze King and bearing a Blaze
King label of approval.
Any statement or representation of Blaze King Products and their performance contained in Blaze King advertising,
packaging literature, or printed material is not part of the Limited Warranty.
The Limited Warranty is automatically voided if the stove’s serial number has been removed or altered in any way. If
the stove is used for commercial purposes, it is excluded from the Limited Warranty.
No dealer, distributor, or similar person has the authority to represent or warrant Blaze King Products beyond the
terms contained within the Limited Warranty. Blaze King assumes no liability for such warranties or representations.
Blaze King will not cover the cost of the removal or re-installation of the stove, hearth, facing, mantels, venting or
other components.
Labor to replace or repair items under this Limited Warranty will be covered per our warranty service fee
reimbursement and labor rates are set per component schedule. Labor rates vary from location to location and as
such total labor costs may not be covered. Please consult with your dealer or service technician for any additional
charges such as travel time or additional labor charges that may apply.
For parts of the Blaze King woodstove or fireplace insert warranted beyond the first year, the five year limited warranty
will have the same obligations as described in this document, provided, however that the purchaser shall pay the
following percentage of the then current retail cost of the repair or the replacement, according to the year after
purchase in the which the defect is brought to the attention of Blaze King.*** During the 2nd year----purchaser pays
20%. 3rd year ----purchaser pays 40%. 4th year -----purchaser pays 60%. 5th year---- purchaser pays 80%.
If a defect or problem is determined by Blaze King to be non warrantable, Blaze King is not liable for travel costs for
service work. In the event of in-home repair work, the customer will pay any in-home travel fees or service charges
required by the Authorized Dealer.
At no time will Blaze King be liable for any consequential damages which exceed the purchase price of the unit. Blaze
King has no obligation to enhance or modify any stove once manufactured (example: as a stove model evolves, field
modifications or upgrades will not be performed).
This Limited Warranty is applicable only to the original purchaser and it is nontransferable.
This warranty only covers Blaze King Products that are purchased through an authorized Blaze King dealer.
If for any reason any section of the Limited Warranty is declared invalid, the balance of the warranty remains in effect
and all other clauses shall remain in effect.
The Limited Warranty is the only warranty supplied by Blaze King, the manufacturer of the stove. All other warranties,
whether express or implied, are hereby expressly disclaimed and the purchaser’s recourse is expressly limited to the
Limited Warranty.
Blaze King and its employees or representatives will not assume any liability for damages, either directly or indirectly,
caused by improper usage, operation, installation, servicing or maintenance of this stove.
Blaze King reserves the right to make changes without notice. Please complete and mail the warranty registration
card and have the installer fill in the installation data sheet in the back of the manual for warranty and future reference.
Blaze King is responsible for stocking parts for a maximum of seven (7) years after discontinuing the manufacture
or incorporation of the item into its products. An exception to this would be if an OEM supplier is not able to supply a
part.
OM-BRII90 E V1.04 wo768
August 25, 2015
BRII/90
Page 38
NOTES
OM-BRII90 E V1.04 wo768
August 25, 2015
BRII/90
Page 39
NOTES
OM-BRII90 E V1.04 wo768
August 25, 2015
BRII/90
Page 40
INSTALLER NOTES
Installer: Please complete the following information
Dealer Name & Address:________________________________________________________
____________________________________________________________________________
Installer (print): _______________________________________________________________
Installer (sign): _______________________________________________________________
Phone #: ____________________________________________________________________
Date Installed:________________________________________________________________
Serial No.: ___________________________________________________________________
OM-BRII90 E V1.04 wo768
August 25, 2015