Description Standards

Description Standards
Technical
Datasheet
3M™ Aura™ 9300+ Series
Particulate Respirators
Description
Standards
The 3M™ Aura™ 9300+ Series Particulate Respirators provide
effective respiratory protection for use in industries where workers
will be exposed to dust particles and/or non-volatile liquid particles.
These products meet the requirements of recently amended
European Standard EN 149:2001 + A1:2009, filtering facepiece
respirators for use against particles. They should be used to protect
the wearer from solid and non-volatile liquid particles only.
• Tested and CE Approved to EN 149:2001+A1:2009
• Foldable, easy to store, proprietary 3-panel design
accommodates facial movement for wearer comfort
• Low breathing resistance filter technology gives effective
filtration with low breathing resistance for consistent high
quality performance
• Sculpted nose panel conforms to the nose and contours of the
face and helps improve compatibility with 3M eyewear
• Innovative chin tab designed for ease of donning and
adjustment to help achieve a comfortable fit
• 3M™ Cool Flow™ exhalation valve offers improved comfort
in hot humid environments and/or where work is hard and
physical*
• Embossed top panel helps reduce fogging of eyewear
• Individual hygienic packaging helps protect the respirator
from contamination before use
• Large, soft nose foam is comfortable on the skin
• Coloured headbands for easy identification: yellow for FFP1,
blue for FFP2 and red for FFP3
Materials
The following materials are used in the production of the 3M™
Aura™ 9300+ Series Particulate Respirators:
• Straps
Polyisoprene
• Staples
Steel
• Nose Foam
Polyurethane
• Nose Clip
Aluminium
• Filter
Polypropylene
• Valve*
Polypropylene
• Valve diaphragm*
Polyisoprene
These products do not contain components made from natural
rubber latex.
Maximum mass of products:
• Unvalved (9310+, 9320+ & 9330+) = 10g
• Valved (9312+, 9322+ & 9332+) = 15g
Products are classified by filtering efficiency and maximum total
inward leakage performance (FFP1, FFP2 and FFP3), also by
usability and clogging resistance.
Performance tests in this standard include filter penetration;
extended exposure (loading) test; flammability; breathing resistance
and total inward leakage. Reusable products are also subjected to
cleaning, storage and mandatory clogging resistance tests
(clogging is optional for non reusable products). A full copy of
EN 149:2001+A1:2009 can be purchased from your national
standards body.
Designations:
R = Reusable
NR = Non reusable (single shift use only)
D = Meets the clogging resistance requirements
Approvals
These products meet the requirements of the European Community
Directive 89/686/EEC (Personal Protective Equipment Directive) and
are thus CE marked.
Certification under Article 10, EC Type-Examination and Article 11, EC
quality control, has been issued for these products by BSI Product
Services, Maylands Avenue, Hemel Hempstead, HP2 4SQ, UK
(Notified Body number 0086).
Applications
These respirators are suitable for use in concentrations of solid and
non-volatile liquid particles up to the following limits:
Model
EN 149+A1
Classification
9310+ FFP1 NR D
Exhalation Threshold Limit Value,
Valve
TLV
Unvalved
4
9312+ FFP1 NR D
Valved
4
9320+ FFP2 NR D
Unvalved
12
9322+ FFP2 NR D
Valved
12
9330+ FFP3 NR D
Unvalved
50
9332+ FFP3 NR D
Valved
50
Respiratory protection is only effective if it is correctly selected, fitted and
worn throughout the time when the wearer is exposed to hazards.
* 9312+, 9322+ and 9332+ models only
Selection Guide
FFP3
Organic
Vapour
•
•
Water-Based - brush / roller / spray applied
•
•
Wood Preservatives
•
•
FFP1
Painting,
Varnishing,
Spraying,
Coating,
Mixing
FFP2
Solvent-Based - brush / roller applied
Solvent-Based - spray applied
Rust, most Metals, Filler, Concrete, Stone
•
•
Cement, Wood, Steel,
•
Paints, Varnish, Anti-rust coating
•
Stainless Steel, Anti-fouling varnish
•
Resins, Reinforced plastics (carbon / glass fibre)
Construction /
Maintenance
Metal working /
Foundries
Cleaning /
Waste Removal
•
•
Scabbling, Shot-creting (concrete dust)
•
•
•
Plastering, Rendering, Cement mixing
•
•
•
Demolition
•
•
•
•
Spray foam, Loft Insulation
•
•
Welding, Soldering
•
•
Electro-plating
•
•
Finishing, Slotting, Drilling, Riveting, Machining
•
•
Oxyacetylene cutting
•
•
Molten metal handling, Smelting
•
•
Disinfection, Cleaning
•
•
•
Waste removal
•
•
•
Pollen, Animal dander
Other
Industrial Applications
•
•
•
Diesel exhaust / Smoke
•
Handling infected animals, Culling
•
•
•
•
•
•
Straw chopping, Composting, Harvesting
•
•
Pesticides, Insecticides (crop spraying)
•
•
Tunnelling, Drilling, Grinding, Excavation
•
•
Pumping, Dredging, Washing
•
•
Cutting, Sawing
•
•
Changing Filters
•
•
Inks, Dyes, Solvents, Chemicals
•
•
•
Powdered Additives / Chemicals
•
•
•
Pharmaceuticals
•
•
•
Rubber / Plastics processing
•
•
•
Oil and Gas Extraction / Processing
•
•
•
Pottery, Ceramics
Wood / Paper Mills
•
•
**Tuberculosis
Mining /
Quarrying
•
Ask 3M
Mould / Fungus, Bacteria**, Viruses
Feeding livestock, Cleaning sheds / harvesters
•
•
•
Asbestos removal
Agriculture /
Forestry
•
Groundwork, Earth moving, Piling, Underpinning
Asbestos handling
Allergens /
Biohazards
Welding
Ask 3M
Powder Coating
Sanding,
Stripping,
Grinding,
Cutting,
Drilling
Acid
Gas
•
•
•
•
•
•
This selection guide is only an outline designed to focus on products which may be appropriate for typical applications - it should not be used as the only means of selecting a product. Selection of
the most appropriate personal protective equipment (PPE) will depend on the particular situation and should be made only by a competent person knowledgeable of the assessed risks, actual working
conditions and limitations of PPE. Details regarding performance and limitations are set out on the product packaging and user information. If in doubt, contact a safety professional or 3M.
For respiratory training and advice please contact your local 3M representative.
Storage and Transportation
Fit Check
The 3M™ Aura™ 9300+ Series Particulate Respirators have a
shelf life of 5 years. End of shelf life is marked on the product
packaging. Before initial use, always check that the product is
within the stated shelf life (use by date). Product should be
stored in clean, dry conditions within the temperature range:
– 20°C to + 25°C with a maximum relative humidity of <80%.
When storing or transporting this product use original packaging
provided.
1. Cover the front of the respirator with both hands being careful
not to disturb the fit of the respirator.
2. (a) UNVALVED respirator - EXHALE sharply;
(b) VALVED respirator - INHALE sharply.
3. If air leaks around the nose, re-adjust the noseclip to
eliminate leakage. Repeat the above fit check.
4. If air leaks at the respirator edges, work the straps back
along the sides of the head to eliminate leakage. Repeat the
above fit check.
Disposal
Contaminated products should be disposed as hazardous waste
in accordance with national regulations.
If you CANNOT achieve a proper fit DO NOT enter the
hazardous area. See your supervisor.
Users should be fit tested in accordance with national requirements.
Fitting Instructions
For information regarding fit testing procedures, please contact 3M.
See Figure 1.
Product Range
Before fitting device, ensure hands are clean.
1. With reverse side up and using the tab, separate top and
2.
3.
4.
5.
6.
bottom panels to form a cup shape. Bend slightly at centre of
the noseclip.
Ensure both panels are fully unfolded.
Cup respirator in one hand with open side towards face. Take
both straps in other hand. Hold respirator under chin, with
nosepiece up, and pull straps over head.
Locate the upper strap across the crown of the head and
the lower strap below the ears. Straps must not be twisted.
Adjust top and bottom panels for a comfortable fit, ensuring
panels and chin tab are not folded in.
Using both hands, mould noseclip to the shape of the lower
part of the nose to ensure a close fit and good seal. Pinching
the noseclip using only one hand may result in less effective
respirator performance.
The seal of the respirator on the face should be fit-checked
before entering the workplace.
9310+ respirator
9312+ respirator
9320+ respirator
Figure 1
9322+ respirator
1
2
3
9330+ respirator
4
5
6
9332+ respirator
Warnings and Use Limitations
•
Always be sure that the complete product is:
- Suitable for the application;
- Fitted correctly;
- Worn during all periods of exposure;
- Replaced when necessary.
•
Do not use in atmospheres containing less than 19.5% oxygen. (3M definition.
Individual countries may apply their own limits on oxygen deficiency.
Seek advice if in doubt).
•
Do not use for respiratory protection against atmospheric contaminants/concentrations which are unknown or immediately dangerous to life and health (IDLH).
•
Proper selection, training, use and appropriate maintenance are essential in order
for the product to help protect the wearer from certain airborne contaminants.
•
Do not use with beards or other facial hair that may inhibit contact between
the face and the product thus preventing a good seal.
•
Failure to follow all instructions on the use of these respiratory protection
products and/or failure to properly wear the complete product during all periods
of exposure may adversely affect the wearer’s health, lead to severe or life
threatening illness or permanent disability.
•
Leave the contaminated area immediately if:
a) Breathing becomes difficult.
b) Dizziness or other distress occurs.
•
•
For suitability and proper use follow local regulations, refer to all information
supplied or contact a safety professional/3M representative.
Discard and replace the respirator if it becomes damaged, breathing resistance
becomes excessive or at the end of the shift.
•
Never alter, modify or repair this device.
•
Before use, the wearer must be trained in use of the complete product in
accordance with applicable Health and Safety standards/guidance.
•
In case of intended use in explosive atmospheres, contact 3M.
•
These products do not contain components made from natural rubber latex.
•
These products do not protect against gases/vapours.
Important Notice
3M does not accept liability of any kind, be it direct or consequential (including, but not limited to, loss of profits, business and/or goodwill)
arising from reliance upon any information herein provided by 3M. The user is responsible for determining the suitability of the products
for their intended use. Nothing in this statement will be deemed to exclude or restrict 3M’s liability for death or personal injury arising from
its negligence.
3M Centre
Cain Road
Bracknell
Berkshire RG12 8HT
United Kingdom
Tel: + 44 (0) 1344 858000
Web: www.3M.eu/Safety
Please recycle.
© 3M 2011. All rights reserved.
EU_MASTER_01
3M Occupational Health & Safety Division
EMEA Region
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF