L0614SC Pump Data
52 BHP Intermittent Duty
Specifications
Pump Model
L0614SC
Configuration
Horizontal Triplex
Number of Pistons
3
Stroke Length
1.5 Inches
Frame Load Rating
2,800 lbs
Pump Weight (Average)
178 lbs
Direction of Rotation
Top of shaft toward head
Internal Gear Ratio
NA
Intermittent Duty Speed Rating
Minimum Speed
855 RPM
100 RPM
Mechanical Efficiency
90%
Lubrication System (Standard)
Splash, Gravity Return
Lube Oil Capacity
Lube Oil Type
2.5 Quarts
SAE 30
Standard Suction Size
1.50 Inch NPT
Standard Discharge Size
1.25 Inch NPT
Fluid End Material
Ductile Iron
Valve Types
Disc Valves
Performance Table
Pump Model
L0614SC
Piston
Diameter (in)
Displacement
(GAL/REV)
Maximum
Pressure (PSI)
100 RPM
Pump Capacity (GPM) @ Input Speed (RPM)
1.750
0.0469
2,000
4.7
250 RPM
11.7
500 RPM
23.4
750 RPM
35.1
855 RPM
40.1
* Horsepower based on 85 or 90% mechanical efficiency. Actual application horsepower requirements can be calculated using the equation: BHP = (GPM * PSI) / (1714 *
0.85 or 0.90)
* Pump capacities shown are based on 100% volumetric efficiency.
* Dimensions shown are for general sizing purposes and should not be used for construction. Contact FMC for actual dimensions of pump ordered.
* FMC reserves the right to modify this information without prior notice.
For additional information visit buckhornpumps.com
Customer Service
(800) 772-8582
2825 W. Washington St.
Stephenville, TX 76401
www.FMCPumps.com
L06
Cast Pump Engineering Dimensional Outline
• FMC recommends NPSHa (available) exceeds NPSHr (required) by 5 feet of water.
• Take special consideration when calculating NPSHa. Recalculate NPSHa after pump model has been selected for more accurate values.
• NPSHr values are in feet of water. If you are pumping a different liquid than water, convert the required NPSH from water to the liquid
being pumped by dividing the published NPSHr value by the specific gravity of the liquid being pumped.
• FMC published NPSHr values are based on test data collected on specific pumps at the factory and are estimated values. Actual NPSHr
values for an ordered pump can only be determined by a factor test. For NPSH critical applications, contact the factory for additional
information and request an NPSHr test performed on your pump before shipment.
• Pump drawing dimensions in inches.
For additional information visit buckhornpumps.com
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising