S53-341TL, S53-341TMA, S53-342, S53-343TL, S53-343TMA, S53-344, S53-345TL, S53-345TMA, S53-346

S53-341TL, S53-341TMA, S53-342, S53-343TL, S53-343TMA, S53-344, S53-345TL, S53-345TMA, S53-346
Installation
Aerada™ 900 Series
Futura Faucet
With Accu-Zone® (AZ) Infrared Control
S53-341TL���������4" Centerset
S53-341TMA�����4" Centerset w/ TMV
S53-342�������������4" Centerset, no Solenoid Valve
S53-343TL���������Centershank
S53-343TMA�����Centershank w/TMV
S53-344�������������Centershank, no Solenoid Valve
S53-345TL���������4" Centershank w/8" Trim Plate
S53-344 Shown
S53-345TMA�����4" Centershank w/ 8" Trim Plate, TMV
S53-346�������������4" Centershank w/ 8" Trim Plate, no
Solenoid Valve
Supplies Required�������������������������������������������������������������������������������� 2
Dimensions and Configurations������������������������������������������������������������ 2
Installation�������������������������������������������������������������������������������������������� 3
Multi-Faucet Wiring������������������������������������������������������������������������������� 4
Replacing the Sensor��������������������������������������������������������������������������� 5
Troubleshooting������������������������������������������������������������������������������������ 5
IMPORTANT!
Installation
Packing List
IS
TH
SIDE
UP
•
•
•
•
Read this entire installation manual to ensure proper installation. When finished with the
installation, file this manual with the owner or maintenance department. Compliance and
conformity to local codes and ordinances is the responsibility of the installer.
Separate parts from packaging and make sure all parts are accounted for before discarding
packaging material. If any parts are missing, do not begin installation until you obtain the
missing parts.
Make sure that all water supply lines have been flushed and then completely turned off before
beginning installation. Debris in supply lines can cause valves to malfunction.
A transformer (supplied by Bradley or supplier) should be used in conjunction with the 900
Series Futura (AZ) Faucets. The transformer MUST be 24VAC. Connection to 120 VAC could
result in personal injury and will damage the sensor.
When the faucet is mounted on a fixture with a stainless steel bowl, it is recommended that the
bowl have a satin finish rather than a mirrored or highly polished finish.
Product warranties may be found under “Products” on our web site at bradleycorp.com.
215-1680 Rev. C ECN 13-02-001
© 2013 Bradley
Page 1 of 6
3/8/2013
P.O. Box 309, Menomonee Falls, WI USA 53052-0309
PHONE 800.BRADLEY (800.272.3539) FAX 262.251.5817
bradleycorp.com
Aerada 900 Series Futura Faucet
Installation
Supplies Required
• 120 VAC power source and 120 VAC/24 VAC transformer (Bradley part no. S83-005: must be ordered separately)
• OPTIONAL: Remote wiring from faucet to transformer; electrical box for transformer if required by local code
• 18-gauge two-conductor lamp cord (if additional wire length is required)
• Tempered/cold supply piping and fittings to solenoid valve (1/2" NPT)
• 1/4" O.D. tubing
• Pipe fittings, pipe sealant as required
Dimensional Information
4"
(102)
8"
(203)
7"
(178)
2-5/16"
(58)
(mm)
Centerset Mounting
Centershank Mounting
1-1/8"
(29)
1-1/8" (29)
Drilled Hole
3/4" (19)
Drilled Hole
3/8" (10)
Drilled Hole
Washer
Nut
Faucet Stud
Copper Tubing
Nut &
Washer
Copper Tubing
Mounting Configurations
1
2
3
Parts List
4
1
4
Ref.
Part No.
Description
1
110-115
Mounting Nut
6
2
112-002CB
Mounting Washer
7
3
161-151
8" Trimplate Mounting Screw
4
S27-224
Mounting Prepack
5
159-399
8" Trimplate
6
161-078
Sensor Bracket Nut
7
142-002BS
Sensor Bracket Washer
8
-
Sensor Bracket
9
S83-004
Sensor Assembly
10
160-169
Sensor Mounting Screw
2
10
5
8
6
8
7
8
9
9
9
Centerset Mounting
Centershank Mounting
Faucet Components
Fitting Assy.
(S05-193)
Sensor
Sensor
Window
(269-604)
Flow Control
Aerator Assy.
(S05-142A)
2
Adapter
(153-467)
Centershank
Faucet
Shown
3/8/2013Bradley • 215-1680 Rev. C; ECN 13-02-001
Aerada 900 Series Futura Faucet
Installation
Installation
1
Mount Faucet on Deck
Centerset
Faucet
Shown
A
Drill holes in deck to the size and position
for your faucet configuration, as shown on
previous page.
B
Attach faucet and trim plate (if applicable)
securely to deck. Seal around faucet and trim
plate with plumber's putty.
Deck
2
Washer
Nut
Connect Water Supply
Centershank
Faucet
Shown
*Solenoid valve not included on some models.
Hot Inlet
1/2" NPT
Solenoid Valve*
1/4" O.D. Tubing
(Supplied by Installer)
(30" max. length, IPC, section
604.5; UPC, section 604.12)
3
TMA Navigator®
Shown
Cold Inlet
1/2" NPT
Connect the Electric Supply
Centershank
Faucet
Shown
From Transformer
120VAC/24VAC
Transformer
Avalable as a
separate item
(Bradley Part
No. S83-005)
Blue
Brown
Black
Adapter
269-620
Solenoid Valve*
*Solenoid valve not included on some models.
Bradley • 215-1680 Rev. C; ECN 13-02-001
3/8/2013
3
Aerada 900 Series Futura Faucet
Installation
For Units Equipped with TMA Navigator® Mixing Valve, Complete steps 4 and 5 Below:
4
Adjust Temperature with Water Running
This valve is NOT factory preset. Upon installation, the temperature of this
valve must be checked and adjusted to ensure delivery of a safe water
temperature. Water in excess of 110°F (43°C) may cause scalding.
5
Test Unit
A
Loosen Cap Screw about 1/4" (4-6 turns)
and lift up cover (do not remove).
B
Using cover, turn cartridge gently until
desired water temperature is reached. Do
not turn past stops as this may damage
unit. Push cover down and tighten screw.
H
C
DO NOT SKIP THIS STEP!!!
Shut the hot water inlet off by closing hot water inlet valve. While the hot water supply is turned off, check to make sure the cold
water flow is reduced. If the cold water is reduced properly, reopen the hot water supply.
Shut the cold water inlet off by closing the cold water inlet valve. While the cold water supply is off, check to make sure that the hot
water flow has shut down.
Multi-Faucet Wiring
One transformer operates up to
four faucets at one time. Additional
transformer(s) are required for installations
with more than four faucets. Refer to the
transformer's installation manual for remote
mounting instructions.
Brown
Blue
Black
4
3/8/2013Bradley • 215-1680 Rev. C; ECN 13-02-001
Aerada 900 Series Futura Faucet
Installation
Replacing the Sensor
To avoid personal injury and/or damage to the faucet, TURN OFF the electrical power
and water BEFORE beginning any cleaning, troubleshooting or maintenance.
A
Disconnect the sensor wire leads
from the faucet and remove the
faucet from the deck.
B
Following the illustrations at right for
your faucet configuration, remove
the screws and/or nuts holding the
bracket, then carefully remove the
bracket and sensor assembly from
the faucet shell.
Bracket
IR Sensor
C
Remove screws securing the existing
sensor to bracket. Installation of the
new sensor is the reverse process.
Centerset Mounting
Centershank Mounting
Sensor must be flush and parallel with the
lens. Do not force or bend the bracket!
Troubleshooting – Solenoid Valve
S07-068
Problem
Cause
Solution
Faucet
fails to
shut off
and drips.
There is debris trapped
between the diaphragm
and the valve seat
Remove debris between diaphragm and the valve seat:
1. Remove the three #8 Phillips-head screws that hold the solenoid
valve assembly together.
Be careful not to lose the armature or spring (see Parts List).
2. Remove the diaphragm. Remove any particles that have been
trapped between the diaphragm and the valve seat. Rinse off the
diaphragm and inspect for damage. Make sure the center orifice and
both small side orifices are open.
7
8
3. Reassemble in reverse order, being careful not to overtighten the
Phillips-head screws or you may crack the plastic valve body. Tighten
until the armature plate makes contact with the plastic body.
6
4. Reconnect the wiring per diagram on page 3.
5
Faucet
fails to
turn on.
A failed coil for the valve or
loose electrical connection
to the terminal.
Repair loose connection. (If faucet still does not operate, replace coil.)
4
Parts List for S07-068
3
2
10
1
9
Ref.
Part No.
Description
1
118-307
Valve Body, 1/4" Closed
2
269-983
Diaphragm
3
269-577
Armature
4
269-578
Spring
5
269-1729
Armature Housing
6
269-1730
Clamp, Armature Housing
7
269-579
Coil, Solenoid Valve
8
160-447
Screw, #8 x 5/8"
9
125-165
O-Ring, #2-013
10*
125-160
Flow Restrictor, .5 GPM
* Not included with S07-067.
Bradley • 215-1680 Rev. C; ECN 13-02-001
3/8/2013
5
Aerada 900 Series Futura Faucet
Installation
Troubleshooting – Thermostatic Mixing Valve
Before attempting to troubleshoot the valve or disassemble the components, check for the following conditions:
• If stop valves are used, make sure that they are fully open.
• Make sure that the hot and cold inlet pipes are connected properly, and that there are no cross-connections or
leaking stop valves.
• Check the hot water heater output to make sure that it is at least 10° F above the set temperature.
Close the appropriate shut-off valves prior to disassembly and reopen valves after inspection and repair is complete.
Problem
Cause
Solution
External leaks.
Damaged cartridge or
O-rings.
Replace cartridge with part number 269-1927
Improper water temperature
or temperature fluctuation.
Hot water supply is not 10°
above desired set point.
Increase hot water supply temperature
Valve temperature is not
properly set.
Adjust the temperature as shown on page 4 step 4.
Dirt and debris have built
up in the valve or strainer.
1.Check to make sure both hot and cold supplies are connected to
the Navigator mixing valve and that they have water flow.
Limited water flow.
2.Remove cover and U-clip. Remove the cartridge and clean the
strainer. It is not required to grease cartridge, however if desired,
use silicone grease only.
Do not use grease on check valves.
1
Parts List for S01-526
S01-526
2
3
4
Ref.
Part No.
Description
1
160-463
Cap Screw
2
107-582
Cover
3
269-1927
Thermostatic Cartridge
4
198-014
Check Valve*
5
132-051
Retaining Ring*
6
146-079
U-Clip
7
118-319
Valve Body
* Included with Prepack S65-326
5
Tempered Line Adapter Option: Part no. S39-804
6
Strainer
173-028
7
6
3/8/2013Bradley • 215-1680 Rev. C; ECN 13-02-001
Was this manual useful for you? yes no