FDC 100SeriesV
FDC-100 Series
High Accuracy, Flexible Control, Low Cost!
Future Design’s "100" series redefines the standard for 1/16,
1/8 and 1/4 DIN temperature controllers. Fast input scan rates
( 5 per second ), 18 bit input resolution and 15 bit output resolution as well as fuzzy modified PID control provide not only the
highest accuracy, but temperature control minimizing over/under
shoot while maintaining fast process response.
The "100" series can be configured with up to 3 control outputs
(2 PID fuzzy + alarm). A fourth output can be configured for
RS232/485 Modbus or PV analog retransmission.
The 100 series can also be equipped with an isolated transmitter
power supply when the second control output is not required.
Standard software functionality includes Fuzzy Logic + PID, soft
start ramp, Lock out protection, bumpless transfer, user defined
menu operation, timer function, and more. With isolated
inputs/outputs, UL/cUL and CE, the 100 series is the clear choice
for temperature control applications.
FDC - 100
Series Controllers
• Fuzzy Logic PID Temperature Control
• Up to three Control outputs
• 5VDC & 14VDC SSR
• Variety of Alarm modes
• Transmitter Power Supply
• SEL Function to arrange user menu
• Nema 4X/IP65 protection available
• FREE Data Acquisition Software – Multiview
CFR21 Part 11 Features!
FDC-100 Series Specific ations
Power
Indication (4 digit display)
90-250VAC, 50/60Hz
Process Display: 0.56” (4100), .4” (9100,8100) red.
11-26VAC/VDC
Setpoint Display: 0.4” (4100), .31” (9100,8100) green.
Status Indicator: Out1, Out2, Alm, Man, ˚C, ˚F, AT
Input (18 bit A/D resolution)
Thermocouple (T/C): Type J,K,T,E,B,R,S,N,L
Environmental and Physical
RTD: PT 100 ohm RTD (DIN or JIS)
Operating Temperature: -10 to 50˚C
Range: Per table in order manual
Storage Temperature: -40 to 60˚C
Accuracy: Typically better than ± .25% of span
Humidity: 0-90% RH (non-condensing)
Cold Junction Compensation: 0.1˚C/˚C ambient typical
Insulation: 20M ohms minimum (500VDC)
Sensor Break: Protection mode configurable
Common Mode Rejection: 120dB
Dielectric Strength: 2000VAC, 50/60Hz for 1 minute
Shock Resistance: 200m/s2 (20G)
Sample Rate: 5 times per second
Vibration: 10-55Hz, 10m/s2 for 2 hours
Moldings: Flame retardant polycarbonate
Control
Proportional Band: 0.1-500˚C (0.1-900˚F)
Reset (Auto): 0-1000 seconds
Rate (Derivative): 0-360.0 seconds
Cycle Time: 0-.1 to 90 seconds.
IP Panel Rating: IP50 (IP65 optional)
Dimensions\Weight:
9100: 1.99” (H) x 1.99” (W) x 4.12” (D) - 5.3oz (150g)
8100: 3.77” (H) x 1.88” (W) x 2.55” (D) - 7.4oz (210g)
4100: 3.77” (H) x 3.77” (W) x 2.08” (D) - 8.84oz (250g)
Ramp Rate: 0-500˚C (900˚F)/minute or hour
Timer Dwell: 0-4553.6 minutes.
On-Off: with adjustable hysteresis (0.1-90.0˚F)
Control Action: Direct and reverse
P.O. Box 1196 • Bridgeview, IL 60455
888.751.5444 • 888.307.8014 Fax
www.futuredesigncontrols.com
Ordering Information
9100 = 1/16 DIN Controller.
8100 = 1/8 DIN Controller.
4100 = 1/4 DIN Controller.
Enter a number in each box which
corresponds to the specifications you
want when ordering the FDC-100 series.
FDC-9100
FDC-8100 FDC-4100
P ow e r I n p u t
4:
5:
9:
90-250VAC 50/60 HZ
11-26VAC/VDC
Special Order
Signal Input
1:
9:
Thermocouple: J,K,T,E,B,R,S,N,L
RTD: PT100DIN & JIS
Special Order
Output 1
0:
1:
2:
3:
4:
5:
6:
C:
9:
None
Relay 2A/240VAC resistive (SPST)
SSR Drive 5VDC @ 30mA
4-20/0-20mA linear, isolated, maximum load 500 ohms
1-5/0-5VDC linear, isolated, minimum impedance 10K ohms
0-10VDC linear, isolated, minimum impedance 10K ohms
Triac 1A/240VAC
SSR Drive 14VDC @ 40mA
Special Order
Output 2/Alarm2
0:
1:
2:
3:
4:
5:
6:
7:
8:
9:
C:
A:
None
Form A Relay 2A/240VAC resistive (SPST)
SSR Drive 5VDC @ 30mA
4-20/0-20mA linear, isolated, maximum load 500 ohms
1-5/0-5VDC linear, isolated, minimum impedance 10K ohms
0-10VDC linear, isolated, minimum impedance 10K ohms
Triac 1A/240VAC
20VDC/25mA PS Isolated
12VDC/40mA PS Isolated
5VDC/80mA PS Isolated
SSR Drive 14VDC @ 40mA
Special Order
Alarm 1
0:
1:
9:
None
Form C Relay 2A/240VAC resistive (SPDT)
Special Order
C o m m u n i c at i o n s
0:
1:
2:
3:
4:
5:
9:
None
RS-485 Modbus RTU
RS-232 Modbus RTU
0-20/4-20mA retransmission Isolated, max load 500 ohms
0-5/1-5VDC retransmission Isolated, max load 10K ohms
0-10VDC retransmission Isolated, max load 10K ohms
Special Order
Pr ot ec t i ve C l a s s
0:
1:
2:
3:
IP50 Standard
IP65 (Nema 4X)
Din Rail Mount w/IP50 (FDC9100 only)
Din Rail Mount w/IP65 (FDC9100 only)
UL FILE# E197216
CE
January 2004