RevNo Revision note
C
Date
M-CLASS PACK ELECTRICAL ADDITION PG 2
A
Signature Checked
6/18/08
DP
AP
A
GENERAL SPECIFICATIONS
Spa Size: ____ x ____
Shape: __________
Perimeter: ______ LF
Filter Rate: ______GPM
Depth: ______
Area: ______Sq. Ft.
Volume: ______Gals.
Turnover rate: _____Hrs.
EXCAVATION:
Access______________ Min. Width_______________
Fence Removal:
Contr.
Owner
Contr.
Owner
Fence Replaced by:
Remove Dirt
Leave Dirt
Saw Cut
Concrete Removal
Soils/Compaction Report
Contr.
Owner
Not Req'd.
B
B
SPA Model:
________________________
Note: Refer to product specification sheet for details
SPA FILTRATION:
Filter Type:________________________
Make & Model:_____________________
Size:_________ Area:_______________Sq.Ft.
Ciculation Pump Model:__________________HP:_____
______ GPM @ ______ Ft Head Volts_____ PH_____
Ozone Type ______
C
C
HYDRO-THERAPY EQUIPMENT:
Therapy Pump(s): Model______________________
HP______GPM______Volts______Ph.______
SPA HEATING:
Fuel:_______
Natural Gas
Propane
Oil
Make & Model________________________BTU Input____________
Vent Size_________Combustion Ventilation Req'd__________Sq.Ft.
Electric: Make & Model______________________________
KW______ Phase______ Volts______
SPA FITTINGS:
Main Output:
Skimmers:
Inlets:
Therapy Inlets:
D
Size______________
Type______________
Type______________
Type______________
Qty.______________
Qty.______________
Qty.______________
Qty.______________
D
SPA PIPING / PLUMBING:
Filter Plant Face Piping ---- PVC Schedule 40
Gas Heater Piping
Copper
Galvanized
at four feet (4') proceding and & following the heater.
Pool Piping ---- PVC Schedule 40 (Size as per plan)
POOL/SPA CONTRACTOR TO IDENTIFY ALL VALVES & PIPING
E
E
ADDITIONAL:
F
F
CONTRACTOR LICENSE(S):
SITE INFORMATION
N.T.S.
GENERAL CONDITIONS
G
IMPORTANT NOTE FOR GENERAL CONTRACTOR
AT ALL NEW SERVICES & GROUNDING TRENCHES
PROVIDE "WARNING" TAPE AT 12" BELOW GRADE
UNDERGROUND SERVICE ALERT
G
1. ANY SUBSTITUTIONS, REVISIONS OR ADDITIONS TO THE PLANS
ARE TO BE APPROVED IN THE FIELD W/OWNER OR ARCHITECT
CONTRACTOR WILL TAKE FULL RESPONSIBILITY FOR ADJUSTMENTS
TO ANY MATERIAL OR WORK THAT IS NOT APPROVED
2. ALL WORK IS TO BE PERFORMED BY LICENSED, INSURED FIRMS
WHO ARE ACTIVE & EXPERIENCED IN THE RESPECTIVE TRADES
REPRESENTED ON THE DWGS & EXECUTED TO THE HIGHEST
STANDARDS OF THOSE TRADES.
3. CONTRACTOR SHALL COOORDINATE HIS WORK W/ ALL RELATED
TRADES
CALL TOLL FREE
H
6/18/2008 12:59 PM DOC-138.SLDDRW
1
4. ALL WORK SHALL BE IN COMPLIANCE W/ ALL LOCAL CODES,
ORDINANCES & MFG INSTRUCTIONS & SPECIFICATIONS
5. ALL WORK IS SUBJECT TO APPROVAL OF THE OWNER/ARCH
OR THERE REPRESENTATIVE.
1-800-422-4133
6. VERIFY ALL DIM ON SITE & NOTIFY THE OWNER/ARCH OF ANY
DISCREPENCIES PRIOR TO CONSTRUCTION. DO NOT PROCEED
UNTIL ANY NECESSARY ADJUSTMENT ARE MADE
TWO WORKING DAYS BEFORE YOU DIG
7. PROVIDE FOR RACEWAYS FOR OTHER TRADES UNDER SLABS &
FOOTINGS (SUCH AS POOL, PLUMBING, IRRIGATION, ELEC ETC.)
8. CONTRACTOR SHALL PROVIDE ALL LABOR, EQUIP, MATERIALS &
SUPPLIES TO INSTALL ALL WORK ON THE PLANS & AS
SPECIFIED HEREIN
PROJECT SYMBOLS
9. CONTRACTOR SHALL OBTAIN & PAY FOR ALL REQUIRE INSPECTIONS
PERMITS & FEES. PROVIDE NOTICES REQD BY GOVERNMENTAL
AUTHORITIES. FILE DWGS AS NECESSARY, SCHEDULE INSPECTIONS &
TESTS & SUBMIT CERTIFICATES OF APPROVAL UPON COMPLETION
10. CONTRACTOR SHALL PROMPTLY NOTIFY THE OWNER/ARCH OF ANY
WORK OUTLINED ON THE PLANS OR SPECS THAT IS NOT IN ACCORDANCE
W/APPLICABLE LAWS,CODES & REGULATIONS. W/OUT SUCH NOTICE
& APPROPIATE MODIFICATIONS BY OWNER/ARCH, THE CONTRACTOR
ASSUMES FULL RESPONSIBILITY FOR ANY WORK EXECUTED WHICH IS
CONTRARY TO SUCH LAWS, CODES & REGULATIONS
11. DUE TO MANUFACTURING TOLERANCES THERE COULD BE SOME
MINOR DIFFERENCES BETWEEN THE ACTUAL MEASUREMENTS OF
YOUR SPA AND THE DRAWINGS INDICATED HERE. IF SITE PLANNING
IS CRITICAL TO SUCH TOLERANCES, BE SURE TO MEASURE YOUR
ACTUAL SPA.
DATUM PIONT
PROPERTY LINE
8
A-4
BLDG/WALL SECTION
8
A-4
DETAIL SECTION
8
A-4
DETAIL BUBBLE OR
ENLARGED PLAN
NORTH
Itemref
Quantity
Designed by
V Walker
NORTH ARROW
2
3
Doc#
6
Checked by
Angelo P
Approved by - date
J.M. 4-26-02
DIMENSION ONE SPAS
Article No./Reference
Filename
Date
AFS SYSTEMS 4-26-02
Scale
NTS
H
INSTALLATION INFORMATION
CR#
138
1
Title/Name, designation, material, dimension etc
Edition
SITE INFORMATION
4302
7
C
8
Sheet
1 OF 3
6/18/2008 12:59 PM DOC-138.SLDDRW
1
2
3
4
5
6
8
7
RevNo Revision note
Date
Signature Checked
A
P2
A
P1
A
#4 REBAR 18"
O.C. EACH
WAY
1'-6"
FROM GAS
SERVICE
GH
A
P3
B
1'-6"
LOW VOLT LINE
FOR LIGHT
SWIM SPA
OUTLINE ON
SLAB
CHECK LOCAL CODES FOR
PLUMBING / ELECTRICAL
TRENCH INFO
P1 P3
P3
E
Controls/Elec.Heater
Gas Heater (optional)
Pump
Filter
Electrical
SEE NOTE 3 FOR
DETAILS
E
Legend:
E=
SYMBOL
SIZE
TYPE
A
B
C
3"
SCHED. 40
-
SCHED. 40
PER NEC
-
SCHED. 40
PER NEC
Electrical
ELEC
DISCONNECT
NOTES
B
PLUMBING PIPE SCHEDULE
ELECTRICAL STUB-IN
SYMBOL
SIZE
A
E
22'-0"--16' AFS SYSTEMS
-
TYPE
NOTES
SCHED. 40
PER NEC
FILTER END
2
-
FILTER / EQUIPMENT
END
6"
25'-0"--19' AFS SYSTEMS
ELECTRICAL STUB-IN
P1
C/H=
GH=
P=
F=
E=
PIPE SCHEDULE
PLUMBING INLETS/OUTLETS
P2 P2
CHECK LOCAL CODES FOR
ELECTRICAL TRENCH INFO
Legend:
CAUTION:
WHEN USING GAS HEATER
OPTION, ELECTRICAL HEATER
CIRCUITRY MUST BE
DISCONNECTED. SEE WIRING
DIAGRAM AND INSTALLATION
MANUAL FOR ADDITIONAL
DETAILS
EQUIPMENT PAD MUST BE
MIN. 4" ABOVE GRADE
LOW VOLT LINE
FOR DATA CABLE
SEE SCHEDULE FOR PIPE
REQUIREMENTS
5" THK
CONCRETE SLAB
W/
#4 REBAR TIED @
18" O.C.
EACH WAY
FROM ELEC.
SERVICE
C
220V LINE FOR OZONE
FROM ELEC.
SERVICE
240V
240V
C/H
B
A
A
REMOTE EQUIPMENT OPTION (BUILDER'S PACK) IS ONLY
AVAILABLE FOR AQUAPRO 19' & AQUAFIT 16' MODELS.
6"
C
C
NOTES
1. VERIFY ALL DIMENSIONS ON SITE
2. CONTRACTOR SHALL VISIT SITE PRIOR TO BIDDING TO
VERIFY LOCATIONS & SIZES OF ALL EXISTING EQUIPMENT
& INFORM OWNER/ARCH OF ANY DISCREPENCIES
3. THE ELECTRICAL DISCONNECT(GFCI) MUST BE IN LINE
OF SIGHT OF THE SPA, AT LEAST 5' FEET AWAY, BUT NOT
MORE THAN 50 FEET
AFS SYSTEMS
6"
AFS SYSTEMS
12'-0"
D
D
1
N.T.S.
FOUNDATION PLAN
5" THK CONC SLAB
#4 REBAR @ 18" O.C. EACH WAY
4" COMPACTED SAND FILL
FIN GRADE
REMOTE EQUIPMENT DIAGRAM
3"CLR
FROST DEPTH
1'-3" MIN OR
A
-
SCALE :
N.T.S.
1'-0"
E
N.T.S.
2
B
240V
FOUNDATION SECTION
110V
1'6"
4" EQEQ
FROST DEPTH
LOW VOLT LINE FOR
FIREMANS SWITCH
B
E
FROM GAS
SEE SCHEDULE FOR PIPE
REQUIREMENTS
E
CAUTION:
WHEN USING GAS
HEATER OPTION,
ELECTRICAL HEATER
CIRCUITRY MUST BE
DISCONNECTED. SEE
WIRING DIAGRAM
AND INSTALLATION
MANUAL FOR
ADDITIONAL DETAILS
SERVICE
GH
I
FILTER / EQUIPMENT
END
3" CLR
1'-3" MIN OR
ELECTRICAL STUB-IN
1'-0"
FROM ELEC.
SERVICE
B
#4 @ 18" O.C EACH WAY
F
2
VARIES
O
A
PLUMBING INLETS
& OUTLETS
#5 TOP & BOTTOM
EQUIPMENT PAD MUST BE
MIN. 4" ABOVE GRADE
CHECK LOCAL CODES FOR
PLUMBING/ELECTRICAL
TRENCH INFO
CONCRETE SECTION DETAIL
N.T.S.
A
GAS HEATER NOTES
Foundation:
Caution:
Normal use of the Aquatic Fitness
Systems causes large amounts of
water to splash out of the unit.
These foundation specifications
are only for mechanical support
of the AFS. Depending on the
specific installation, additional
provisions will have to be made
for proper removal of the water.
F1 Prior to SLAB CONST, top 6" of underlying soils shall be scarified & reworked to a
min of 2% abv optimum moisture content, & recompacted to a min of 95% of
Standard Proctor Density
F2 Contractor to verify soil bearing pressure. Slab design based on assumed
soil pressure of 1000 PSF. According to table no. 18-1-A, UBC 1997 pg. 2-49
G
F3 Contractor to provide 2 mil. vapor barrier on 4" compacted sand after soil preparation
Reinforcement:
R1 All reinforcement shall conform to ASTM A-615 Grade 60
AFS SYSTEMS
1. VERIFY ALL DIMENSIONS ON SITE
2. GAS HEATER TO BE INSTALLED PER LOCAL CODES AND REGULATIONS
FOR VENTING AND PLUMBING REQUIREMENTS
3. CONTRACTOR SHALL VISIT SITE PRIOR TO BIDDING TO VERIFY
LOCATIONS & SIZES OF ALL EXISTING EQUIPMENT & INFORM
OWNER/ARCH OF ANY DISCREPENCIES
SELF CONTAINED DIAGRAM
ELECTRICAL NOTES
1. VERIFY ALL DIMENSIONS ON SITE
2. ALL CONCRETE SLABS & FOOTINGS TO BE
POURED MONOLITHICALLY
3. CONTRACTOR SHALL VISIT SITE PRIOR TO BIDDING
TO VERIFY LOCATIONS & SIZES OF ALL EXISTING
EQUIPMENT & INFORM OWNER OF ANY DISCREPANCIES
4. CONTRACTOR SHALL FURNISH ALL MATERIALS, LABOR,
EQUIPMENT, TRANSPORTATION & SERVICES NECESSARY
FORCOMPLETION OF WORK. ALL MATERIALS & WORK
SHALL COMPLY W/APPLICABLE CODES & GOVERNING
REGULATIONS & MEET THE APPROVAL OF THE LOCAL
JURISDICTION
5. TAKE ALL PRECAUTIONS NECESSARY TO PROTECT THE
MATERIALS BEFORE, DURING & AFTER INSTALLATION. IN
THE EVENT OF DAMAGE, IMMEDIATELY REPAIR ALL
DAMAGED &DEFECTIVE WORK TO THE APPROVAL OF
THE OWNER/ARCH AT NO ADDITIONAL COSTS TO THE
OWNER
6. THESE DRAWINGS ARE DIAGRAMMATIC. CONTRACTOR
SHALL BE RESPONSIBLE FOR COORDINATING HIS WORK
W/ ALL OTHER TRADES.
7. ACCURATE AS-BUILT DRAWINGS SHALL BE MADE DURING
CONSTRUCTION & SUBMITTED FOR APPROVAL UPON
COMPLETION OF INSTALLATION
8. ALL APPLIANCES DESIGNED TO BE FIXED IN POSITION
SHALL BE SECURELY FASTENED IN PLACE
9. DUE TO MANUFACTURING TOLERANCES THERE COULD
BE SOME MINOR DIFFERENCES BETWEEN THE ACTUAL
MEASUREMENTS OF YOUR SPA AND THE DRAWINGS
INDICATED HERE. IF SITE PLANNING IS CRITICAL TO SUCH
TOLERANCES, BE SURE TO MEASURE YOUR ACTUAL SPA.
1.
Gas Heater
Water Flow Out
Water Flow In
Electrical
PLUMBING PIPE SCHEDULE
R2 Reinforced steel shall be designed, detailed, fabricated & placed in accordance w/
latest ACI Detailing Manual (SP-66) & CRSI Manual Standard Practice
SYMBOL SIZE
R3 Rebar to overlap 24" @ each corner
A
B
R4 Splices in reinforcement shall occur @ points of minimum stress & lap 40x bar diameter minimum u.n.o.
TYPE
2"
SCHED. 40
-
SCHED. 40
NOTES
E
INSTALL SPA AT LEAST 5 FEET FROM ALL UNBOUNDED
METAL SURFACES
2. ELECTRICAL SUPPLY FOR THE SPA MUST COMPLY WITH
SECTION 680-42 OF THE NATIONAL ELECTRICAL CODE,
ANSI/NFPA 70-1993
3. THE ELECTRICAL DISCONNECT(GFCI) MUST BE IN LINE
OF SIGHT OF THE SPA, AT LEAST 5' FEET AWAY, BUT NOT
MORE THAN 50 FEET
4. SUPPLY WIRE MUST BE A MINIMUM #6 AWG COPPER OR
OTHER APPROVED BY LOCAL CODES AND GUIDELINES
DEPENDING ON INSTALLATION
5. WITH LX-15 LOWER CONTROL: MINIMUM 60 AMP SERVICE
REQUIRED FOR SPAS WITH LOAD SHARING.
WITH GECKO M-CLASS LOWER CONTROL: MINIMUM 40 AMP
SERVICE REQUIRED FOR SPAS WITH LOAD SHARING.
6. WITH LX-15 LOWER CONTROL: NON LOAD SHARING SPAS
WILL REQUIRE (1) 60 AMP + (1) 50 AMP SERVICE.
WITH GECKO M-CLASS LOWER CONTROL: NON LOAD
SHARING SPAS WILL REQUIRE (1) 50 AMP SERVICE.
7. DUAL TEMP WILL REQUIRE (1) ADDITIONAL 40 AMP SERVICE.
8. ALL WORKS & MATERIALS SHALL BE IN FULL ACCORDANCE
W/ THE NATIONAL ELECTRICAL CODE (ENFORCED BY LOCAL
AUTHORITY) & ALL APPLICABLE STATE & LOCAL LAWS &
REGULATIONS. NOTHING IN THESE PLANS OR SPECS SHALL BE
CONSTRUCTED AS TO PERMIT WORK NOT CONFORMING TO
THE MOST STRINGENT OF THESE CODES. SHOULD CHANGES
BE NECESSARY IN THE DWGS OR SPECS TO MAKE WORK
COMPLY W/THESE REQUIREMENTS, THE SUBCONTOR SHALL
IMMEDIATELY (ESPECIALLY BEFORE BIDDING SUBMITTAL)
NOTIFY OWNER/ARCH IN WRITING & CEASE WORK ON PARTS
ON THE CONTRACT WHICH ARE AFFECTED
9. EXTENT OF WORK IS INDICATED BY DRAWINGS &
SPECIFICATIONS & IS SUBJECT TO THE TERMS & CONDITIONS
OF CONTRACT. THE WORK SHALL CONSIST OF FURNISHING
ALL LABOR, EQUIP, MATERIALS & SUPPLIES NECESSARY FOR
A COMPLETE & OPERATIONAL ELECTRICAL SYSTEM.
THIS INCLUDES WORK NOT MENTIONED OR SHOWN WHICH
IS NECESSARY FOR SUCCESSFUL OPERATION OF ALL SYSTEMS
10. UTILITY SERVICE REQUIREMENTS ARE SHOWN ON DRAWINGS
BASED ON INFORMATION AVAILABLE @ THE TIME & IS NOT
GUARANTEED
11. SEE OWNERS MANUAL FOR ADDITIONAL ELECTRICAL
CONNECTION DETAILS
GENERAL NOTES & CONDITIONS
Concrete:
SCALE :
H
Itemref
Slump
2"-4"
Designed by
V Walker
C3 verify in field w/owner location of all depressions, openings, cast-in-place accessories
etc. prior to construction
CONCRETE SPECIFICATIONS
1
Quantity
Title/Name, designation, material, dimension etc
Article No./Reference
Checked by
Angelo P
Date
1-27-02
Approved by - date
J.M. 1-27-02
DIMENSION ONE SPAS
SCALE :
2
VARIES
1
REMOTE GAS HEATER DIAGRAM
3
SCALE :
3
VARIES
6
Doc#
DOC-138
CR#
NONE
N.T.S.
C1 Conc work shall be executed in strict accordance w/latest American Concrete Institute
(ACI 318-95)
Aggregate
1"
4
F
G
PER NEC
R5 Provide one extra #4 bar x 20'-0" into concrete footing for electrical user ground. Verify location
of electrical meter w/electrical sub-contractor
C2 Conc specs shall be as follows:
28 Day Strength
note:
2500 psi
Portland Cement shall conform
to ASTM C-150. Aggregate shall
conform to ASTM C-33 (1" max aggregate size)
VARIES
N.T.S.
GENERAL NOTES
Legend:
GH=
O=
I=
E=
SCALE :
3592
Filename
DETAILS
H
INSTALLATION INFORMATION
Edition
AFS System
7
Scale
NTS
5
C
8
Sheet
2 OF 3
6/18/2008 12:59 PM DOC-138.SLDDRW
1
2
3
4
5
6
7
8
RevNo Revision note
A
A
A
B
C
B
Signature Checked
E
C
D
Date
E
F
D
A
F
90 1/4"
90 1/4"
90 1/4"
B
B
228"
192"
228"
C
C
62"
52"
D
52"
D
9"
45" 36"
56 1/2"
27" 18"
36"
47 1/2"
27" 18"
9"
18"
27"
36"
9"
48"
E
SECTION E-E
SECTION C-C
SECTION A-A
E
24 1/2"
F
39 1/2"
24"
32"
24"
39 1/2"
39 1/2"
59"
F
24"
SECTION F-F
SECTION D-D
SECTION B-B
G
G
SCALE :
AQUAPRO 19
VARIES
1
AQUAFIT 19 DUAL TEMP
SCALE :
VARIES
2
AQUAFIT 16
Itemref
NOTE:
H
SCALE :
Quantity
Designed by
V Walker
DUE TO MANUFACTURING TOLERANCES THERE COULD BE SOME MINOR DIFFERENCES BETWEEN THE ACTUAL MEASUREMENTS OF
YOUR SPA AND THIS DRAWING. IF SITE PLANNING IS CRITICAL TO SUCH TOLERANCES, BE SURE TO MEASURE YOUR ACTUAL SPA.
Title/Name, designation, material, dimension etc
Article No./Reference
Checked by
Angelo P
Date
1-27-02
Approved by - date
J.M. 1-27-02
DIMENSION ONE SPAS
Doc#
CR#
138
1
2
3
6
VARIES
Filename
SWIM SPA
7
H
INSTALLATION INFORMATION
Edition
AFS Systems
4302
Scale
NTS
3
C
8
Sheet
3 OF 3