Curved Drapery Track Template Instructions
Please read through all of these instructions before beginning your template.
Important Note:
Standard Curved Drapery Track
Lutron provides standard curved drapery tracks to fit
around 90 degree bends. These tracks will have a
bend radius of 20 inches. This solution does not
require the creation of a template, and can be found
as a drapery track option in the Shade Configuration
Tool (SCT). To specify, select the Line Items tab in the
SCT, then click on the Add Line Item dropdown where
you will select Standard Curved Drapery Track.
Lutron drapery track can be bent to fit a curved wall, bay window, and many
other special applications.
“S” bends can only be achieved by splicing two bends together.
No splice
Important Note:
Splices cannot be made on a curve.
A splice can only be made on a straight
portion of track that is at least 18 inches long.
A paper template is the only way to ensure accurate curving of the drapery track.
A checklist is included on pages 9 and 10 to help you provide Lutron with all the
information needed to make the curved track with a minimum amount of delay.
Please be sure to use the checklist and attach it to your template prior to
shipping template to Lutron.
More information is always better than not enough information. Digital
photographs help Lutron to see the application area for the curtain track. Email
photos to shadingquotes@lutron.com.
Before beginning with a curved track order, you must obtain a “COM” number to identify the
materials that you are forwarding to us for review. This number will be used to track your order
throughout the process and it is important that it appears on the template and your
documentation. Without a COM number, your template will be rejected.
To obtain your COM number, either call the Lutron Shading Quotes department at
1 (800) 446-1503 or e-mail shadingquotes@lutron.com
Do not begin a template or ask for a COM# until the job is sold. To obtain a rough budgetary
estimate, submit your quote, with necessary notes, via the SCT or email the Lutron Shading
Quotes department and give them measurements and details of track (such as constant or
variable radius, single/dual/tandem track, and splice or no splice.).
1
24/7 Technical Assistance
1.800.523.9466
Before starting template, please be aware of some
limitations for Lutron curved drapery track:
• Maximum track length is 18 feet without a splice joint.
• With a splice joint, track may be up to 36 feet long.
• Splices can only occur in straight sections of drapery track. Splice must occur on a
straight length of track at least 18 inches long.
• Tight bends more than 90º (i.e. where the two ends of the track bend in towards
each other as shown below) are not possible.
Tight bends are
not possible.
• Tracks have to have a minimum bend radius of 20 inches.
• Minimum spacing for dual tracks is 5 ½ inches center-to-center.
• Finished track may vary ± ¾ inches from template.
18 feet maximum without splice, 30 feet
with splice. Splice can only be located
in straight sections.
18 feet
maximum
Splices not
permitted on
curves
5½
inches
minimum
center-tocenter
2
24/7 Technical Assistance
1.800.523.9466
Other things to consider:
In the above picture, the bend on the left is tighter than that on the right. Multiple
bends like this on one track are very difficult to make. If the track can be a single
radius, it can be made more accurately.
Note: A splice cannot be used in this example as there is no straight portion of
track available.
Pockets should allow ample room for the track
and drapery.
P
Allow ½ inch
between ends of
drapery track and
walls
Recommended
Dimension
Wall
Mount
Ceiling
Mount
Dual Track
P
7 inches
6 inches
14 inches
½
inch
3
½
inch
24/7 Technical Assistance
1.800.523.9466
Required tools:
sharpie black marker
2” or 3” wide masking tape
scissors
digital camera
tape measure
roll of contractor paper*
*Anything other than contractor paper or poster paper will be rejected.
Helpful tool, not required:
compass/divider
Useful to scribe centerline of track
at a set distance from the wall.
4
24/7 Technical Assistance
1.800.523.9466
Begin by taping contractor paper together close to wall surface.
Use the floor or the ceiling, whichever follows the curvature best.
Template shown on floor, against window wall.
Contractor Paper
Tape edges
securely
Minimum 12”
Using a compass or similar tool, follow wall profile to trace track centerline onto paper.
After completing the trace, go over the pencil line with the black marker.
The typical distance for wall mounted track is 3½ inches from wall surface, however,
your distance may be greater for the curtain to clear things like handles, window sills,
columns, vents, etc.
3½ inches for typical wall mount
5
24/7 Technical Assistance
1.800.523.9466
Once track centerline has been traced, be sure to mark the additional features
needed to build the track. Be sure to write down what each mark signifies.
Mark center draw location
(if applicable)
Mark wall
location
Mark drive
location(s)
Center
Draw
ll
Wa
Drive
D
En
do
ft
Tape business card
to template
A - created on ceiling
or
B- created on floor
Note whether template
was drawn looking at
ceiling (A), or looking at
floor (B). (see below)
Track
centerline
ra
ck
Mark ends of track
and extents of pocket
if track will be
mounted in a pocket
d
En
t
of
Ceiling
(A) looking at ceiling
Wall
Template
Drapery Track
Window
Template
(B) looking at floor
Wall
Floor
6
24/7 Technical Assistance
1.800.523.9466
ck
ra
Take a digital photo of the finished template in place.
Take several photos of the area where the curtain track will be mounted.
Email photos to shadingquotes@lutron.com
• Be sure that the template is taped together in one piece. Mark an “X” over each seam of
paper so that if template shifts in shipping, Lutron will have a reference as to where to join
those pieces. Note: Separate pieces will be rejected.
• Each curved track should have its own template.
The only exception is dual tracks, which can be on the same template.
Write COM # on template.
Tape both pages of the checklist to
the template (pages 9 and 10)
Split
A – created on ceiling
or
B- created on floor
ll
Wa
COM# 123456
En
ft
do
Drive
ck
ra
End of track
7
24/7 Technical Assistance
1.800.523.9466
Carefully roll template (DO NOT FOLD*) and place into a sturdy shipping tube.
* Folding makes it difficult to lay flat, which may distort the true size and shape of curve.
Write your COM#, Quote #, Job Name, and Job info on the outside of the tube.
Ship to:
Lutron Shading Solutions
11520 Sun Shade Lane
Ashland, VA 23005
ATTN: Your COM #
It is of the highest importance that all items requested in the instructions be
followed. A production engineer will review the template and advise if it is approved
or if additional information/revisions are needed.
If all information was provided correctly and meets the requirements, your curved
track layout will be approved for manufacture. Production of the track will begin
after approval of the template and receipt of a purchase order. Lead time for
shipment of the completed track(s) begins after receipt of the order and approval of
the template.
8
24/7 Technical Assistance
1.800.523.9466
CHECKLIST – CHECKLIST – CHECKLIST – CHECKLIST – CHECKLIST – CHECKLIST
Use this checklist to help you remember to provide all the
information needed. Attach both pages of the checklist to the
template when you have completed it.
Contact Lutron Shading Quotes if you
do not have a COM number. (See pg. 1)
COM#
Job Name
Quote #
Name
Address
Contact
Info
Phone #
Email address
Drapery Track Configuration – Check appropriate boxes, fill in required dimensions,
refer to figures below.
Single or
Indicate spacing between tracks (S)
Dual
Wall Mount or Ceiling Mount Indicate distance from wall (D)
Single Track
Tandem Tracks
Dual Tracks
Left draw
Right draw
Center draw
Left draw
Right draw
Center draw
(viewed facing window)
Left
inches
inches
Indicate pocket width (P)
If possible, mark pocket size on the paper template (below)
Pocket Mount
Drive Side:
inches
Right
Recommended
Dimension
Wall
Mount
Ceiling
Mount
Dual Track
P
7 inches
6 inches
14 inches
D
S
D
Dual Tracks
Single Track
Min.
5 ½”
Min.
3 ½”
P
Min.
3 ½”
P
Window
Window
9
24/7 Technical Assistance
1.800.523.9466
CHECKLIST – CHECKLIST – CHECKLIST – CHECKLIST – CHECKLIST – CHECKLIST
Use this checklist to help you remember to provide all the
information needed. Attach both pages of the checklist to the
template when you have completed it.
The items below must be included to ensure that your template is approved.
Minimum bend radius is no less than 20 inches.
Clearance to wall and other obstacles at least 3½ inches.
Drive location(s) is(are) marked on template.
Orientation marked on template (either A, or B) – see page 6
Ends of track and ends of pocket are marked on template.
If track is a tandem system or a center draw, mark center of
track on template.
Wall or pocket position is marked on template.
Digital photos taken of template and wall location for track.
COM# written on template.
Photos emailed to shadingquotes@lutron.com
Tape both pages of checklist to template.
10